1.
Molecules ; 24(22)2019 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-31717646

RESUMO

A method has been developed for the separation and quantification of terpenic compounds typically used as markers in the chemical characterization of resins based on capillary liquid chromatography coupled to UV detection. The sample treatment, separation and detection conditions have been optimized in order to analyze compounds of different polarities and volatilities in a single chromatographic run. The monoterpene limonene and the triterpenes lupeol, lupenone, ß-amyrin, and α-amyrin have been selected as model compounds. The proposed method provides linear responses and precision (expressed as relative standard deviations) of 0.6% to 17%, within the 0.5-10.0 µg mL-1 concentration interval; the limits of detection (LODs) and quantification (LOQs) were 0.1-0.25 µg mL-1 and 0.4-0.8 µg mL-1, respectively. The method has been applied to the quantification of the target compounds in microsamples. The reliability of the proposed conditions has been tested by analyzing three resins, white copal, copal in tears, and ocote tree resin. Percentages of the triterpenes in the range 0.010% to 0.16% were measured using sample amounts of 10-15 mg, whereas the most abundant compound limonene (≥0.93%) could be determined using 1 mg portions of the resins. The proposed method can be considered complementary to existing protocols aimed at establishing the chemical fingerprint of these kinds of samples.


Assuntos
Cromatografia Líquida , Resinas Vegetais/química , Terpenos/análise , Terpenos/química , Cromatografia Líquida/métodos , Limite de Detecção , Estrutura Molecular
2.
Anal Chem ; 86(3): 1347-51, 2014 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-24428122

RESUMO

A simple, fast, and highly selective and sensitive colorimetric assay to detect nanomolar levels of spermine in human urine (healthy donors, cancer patients) is reported. This assay is based on the absence of a competitive organic capping on the gold nanoparticles together with the high affinity of the amine groups of the analyte for the nanoparticle surface.


Assuntos
Colorimetria/métodos , Espermina/urina , Urinálise/métodos , Biomarcadores/urina , Ouro/química , Humanos , Limite de Detecção , Nanopartículas Metálicas/química
3.
Anal Bioanal Chem ; 406(8): 2211-5, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24105458

RESUMO

This work demonstrates the application of silica supported Fe3O4 nanoparticles as sorbent phase for magnetic solid-phase extraction (MSPE) and magnetic on-line in-tube solid-phase microextraction (Magnetic-IT-SPME) combined with capillary liquid chromatography-diode array detection (CapLC-DAD) to determine organophosphorous compounds (OPs) at trace level. In MSPE, magnetism is used as separation tool while in Magnetic-IT-SPME, the application of an external magnetic field gave rise to a significant improvement of the adsorption of OPs on the sorbent phase. Extraction efficiency, analysis time, reproducibility and sensitivity have been compared. This work showed that Magnetic-IT-SPME can be extended to OPs with successful results in terms of simplicity, speed, extraction efficiency and limit of detection. Finally, wastewater samples were analysed to determine OPs at nanograms per litre.


Assuntos
Compostos Organofosforados/química , Dióxido de Silício/química , Extração em Fase Sólida/métodos , Microextração em Fase Sólida/métodos , Poluentes Químicos da Água/química , Nanopartículas de Magnetita , Compostos Organofosforados/isolamento & purificação , Extração em Fase Sólida/instrumentação , Microextração em Fase Sólida/instrumentação , Águas Residuárias/química , Poluentes Químicos da Água/isolamento & purificação
4.
J Chromatogr A ; 1730: 465101, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-38941795

RESUMO

The greater and more widespread use of chemicals, either from industry or daily use, is leading to an increase in the discharge of these substances into the environment. Some of these are known to be hazardous to humans and the environment and are regulated, but there is a large and increasing number of substances which pose a potential risk even at low concentration and are not controlled. In this context, new techniques and methodologies are being developed to deal with this concern. Miniaturized liquid chromatography (LC) emerges as a greener and more sensitive alternative to conventional LC. Furthermore, advances in instrument miniaturization have made possible the development of portable LC instrumentation which may become a promising tool for in-situ monitoring. This work reviews the environmental applications of miniaturized LC over the last 15 years and discusses the different instrumentation, including off- and on-line pretreatment techniques, chromatographic conditions, and contributions to the environmental knowledge.


Assuntos
Miniaturização , Cromatografia Líquida/métodos , Monitoramento Ambiental/métodos , Poluentes Ambientais/análise
5.
Clin Neurophysiol ; 159: 75-80, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38359552

RESUMO

OBJECTIVE: In Friedreich's ataxia research, the focus is on discovering treatments and biomarkers to assess disease severity and treatment effects. Our study examines high-resolution nerve ultrasound in these patients, seeking correlations with established clinical markers of disease severity. METHOD: Ten patients with Friedreich's Ataxia underwent a comprehensive clinical assessment with established scales (SARA, FARS, mFARS, INCAT, ADL 0-36, IADL). Additionally, they underwent nerve conduction studies and high-resolution nerve ultrasound. Quantitative evaluation of nerve cross-sectional area, conducted at 24 nerve sites using high-resolution nerve ultrasound, was compared with data obtained from 20 healthy volunteers. RESULTS: All the patients had a severe sensory axonal neuropathy. High-resolution nerve ultrasound showed significant increase, in cross sectional area, of median and ulnar nerves at the axilla and arm. The cumulative count of affected nerve sites was directly associated with clinical disability, as determined by SARA, FARS, mFARS, ADL 0-36, and INCAT score, while displaying an inverse correlation with IADL. CONCLUSIONS: Our study shows that high-resolution ultrasound reveals notable nerve abnormalities, primarily in the upper limbs of patients diagnosed with Friedreich's Ataxia. The observed correlation between these nerve abnormalities and clinical disability scales indicates the potential use of this technique as a biomarker for evaluating disease severity and treatment effects. SIGNIFICANCE: Nerve Ultrasound is a potential biomarker of disease severity in Friedreich's Ataxia.


Assuntos
Ataxia de Friedreich , Humanos , Ataxia de Friedreich/diagnóstico por imagem , Procedimentos Neurocirúrgicos , Ultrassonografia , Biomarcadores , Gravidade do Paciente
6.
Food Chem ; 448: 139025, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38522293

RESUMO

Monitoring of the accidental presence of gluten (Glu), resulting from cross-contamination, is imperative in different industries, in particular food industry. The objective of this study was the development of an analytical platform utilizing thin-layer chromatography (TLC) with colorimetric read-out for making binary (yes/no) decisions on surfaces and/or point of these industries. The composition of the extractive phase was optimized with commercial products used in cleaning processing lines. Subsequently, an exploration of TLC separation and detection was undertaken. CN-modified nanosilica plates and 30:70 acetonitrile:water were used to achieve a selective signal for Glu residues. The study of the detection performance showed that both spectroscopic measurement and image analysis were resulted in satisfactory results for quantitate analysis (RSD = 5 %, LOD = 0.12 mg). The practical application of the proposed methodology on surfaces of the food processing lines. This work demonstrated the operational feasibility in detecting gluten cross-contaminations within the food processing industry.


Assuntos
Colorimetria , Contaminação de Alimentos , Glutens , Contaminação de Alimentos/análise , Glutens/análise , Glutens/química , Colorimetria/métodos , Cromatografia em Camada Fina/métodos , Indústria Alimentícia
7.
Sci Total Environ ; 926: 172060, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38552986

RESUMO

This research addresses the issues related with treatment and valorization of brines and nitrate decontamination of surface and ground waters. The objective was to approximate to zero liquid discharge (ZLD) minimizing the environmental impact of brines of an electrodialysis reversal water treatment plant (EDRWTP) as an example. The innovative in flow process was developed from lab to pre-industrial scale and joined several main concepts: ion-exchange equilibrium for softening or demineralization of brines; reversed osmosis to recover suitable water and to enrich the waste in nitrate for efficient electrochemical reduction of NO3- to N2; valorization of subproducts by direct use or by precipitation; and assessment of the whole process by measuring in-line several parameters. The achieved softening was around 98 % and the recovered water from this current by reversed osmosis was 75 %. The brine of this step (25 %) contained around 1500 mg/L of nitrate and it was treated by electrochemical reduction with a Bi/Sn cathode providing a gas current of 60 % of initial nitrate reduced to N2, O2, H2O, NH3 and at least 97 % of H2. The aqueous current contained around 40 % of initial nitrate as ammonium and nitrite lower than 50 and 5 mg/L, respectively. Hypochlorite was added to this last current for oxidizing ammonium and nitrite to N2 and nitrate, respectively, being nitrate and ammonium lower than 50 and 5 mg/L, respectively. After the obtained water was demineralized and conducted to the EDRWTP inlet. The recovery of insoluble salts as calcium carbonate, reuse of saline solutions for the regeneration of process resins and the potential use of hydrogen generated as a by-product during the electrochemical reduction are other possible utilities.

8.
Clin Neurophysiol ; 158: 35-42, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38150916

RESUMO

OBJECTIVE: This longitudinal study aims at assessing the predictive value of facial nerve high-resolution ultrasound (HRUS) for incomplete clinical recovery in patients with Bell's palsy, the most common facial nerve disease. METHODS: We prospectively enrolled 34 consecutive patients with Bell's palsy. All patients underwent neurophysiological testing (including facial nerve conduction study) and HRUS evaluations 10-15 days (T1), one month (T2), and three months (T3) after the onset of Bell's palsy. Patients who did not experience complete recovery within three months were also evaluated after six months (T4). We have then compared the accuracy of HRUS with that of the facial nerve conduction study in predicting incomplete clinical recovery at three and six months. RESULTS: At T1, the facial nerve diameter, as assessed with HRUS, was larger on the affected side than on the normal side, particularly in patients with incomplete recovery at T2, T3 and T4. ROC curve analysis, however, showed that the facial nerve diameter at T1 had a lower predictive value than the facial nerve conduction study for an incomplete clinical recovery at three (T3) and six (T4) months. Still, the facial nerve diameter asymmetry, as assessed with HRUS, had a relatively high negative predictive value (thus indicating a strong association between normal HRUS examination and a good prognosis). CONCLUSIONS: Although HRUS shows abnormally increased facial nerve diameter in patients in the acute phase of Bell's palsy, the predictive value of this technique for incomplete clinical recovery at three and six months is lower than that of the nerve conduction study. SIGNIFICANCE: Nerve ultrasound has a low predictive value for incomplete clinical recovery in patients with Bell's Palsy.


Assuntos
Paralisia de Bell , Paralisia Facial , Humanos , Paralisia de Bell/diagnóstico por imagem , Nervo Facial/diagnóstico por imagem , Estudos de Condução Nervosa , Estudos Longitudinais
9.
Anal Chem ; 85(21): 10013-6, 2013 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-24131247

RESUMO

Silver ions (Ag(+)) can be quantified in situ in the presence of AgNPs by using a colorimetric sensing probe (3,3',5,5'-tetramethylbenzidine). Interestingly, it also enables detection of the Ag(+) adsorbed on the AgNP surface. This is relevant to design new methods to make AgNPs while ensuring the total reduction of Ag(+).

10.
J Chromatogr A ; 1705: 464216, 2023 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-37480726

RESUMO

A micro-solid phase extraction (micro-SPE) device packed with a C18 sorbent (10 mg) has been developed for the enrichment and purification of organic water pollutants prior to their analysis using a portable liquid chromatograph with a dual UV detector. To this end, the sorbent was immobilized at the inlet of a 4 mm syringe filter (0.20 µm), which was modified to reduce its internal volume. The filter was coupled to the needle of the chromatograph. After loading the sample and cleaning the sorbent for analyte purification, the device was installed into the injection port of the chromatograph, and the target compounds were desorbed and transferred directly to the chromatographic column with a small volume of organic solvent. Under optimized conditions, sample volumes as large as 50 mL could be processed with the micro-SPE device, while the analytes were desorbed with only 60 µL of methanol. As a result, efficient preconcentration could be reached, as demonstrated for different water contaminants, namely aclonifen, bifenox, tritosulfuron, triflusulfuron-methyl and caffeine. The proposed micro-SPE device was applied to the analysis of different types of water (river, well, sea, ditch and wastewater). The recoveries of the target compounds in samples ranged from 76 % to 109 %, which allowed their detection at low to sub µg/L levels. All operations were carried out manually, and thus, no additional laboratory instruments such as centrifuges, stirrers or evaporators were required. This proof-of-concept study shows that the proposed micro-SPE approach can be considered a reliable and effective option for the on-site analysis of pollutants in environmental water samples by portable liquid chromatography.


Assuntos
Extração em Fase Sólida , Poluentes Químicos da Água , Extração em Fase Sólida/métodos , Cromatografia Líquida , Água/química , Solventes/análise , Cromatografia Líquida de Alta Pressão/métodos , Poluentes Químicos da Água/análise
11.
Chemosphere ; 336: 139238, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37330060

RESUMO

The degradation of the diphenyl-ether herbicides aclonifen (ACL) and bifenox (BF) in water samples has been studied under different laboratory conditions, using in-tube solid-phase microextraction (IT-SPME) coupled to capillary liquid chromatography (capLC). The working conditions were selected in order to detect also bifenox acid (BFA), a compound formed as a result of the hydroxylation of BF. Samples (4 mL) were processed without any previous treatment, which allowed the detection of the herbicides at low ppt levels. The effects of temperature, light and pH on the degradation of ACL and BF have been tested using standard solutions prepared in nanopure water. The effect of the sample matrix has been evaluated by analysing different environmental waters spiked with the herbicides, namely ditch water, river water and seawater. The kinetics of the degradation have been studied and the half-life times (t1/2) have been calculated. The results obtained have demonstrated that the sample matrix is the most important parameter affecting the degradation of the tested herbicides. The degradation of both ACL and BF was much faster in ditch and river water samples, where t1/2 values of only a few days were observed. However, both compounds showed a better stability in seawater samples, where they can persist for several months. In all matrices ACL was found to be more stable than BF. In samples where BF had been substantially degraded, BFA was also detected, although the stability of this compound was also limited. Other degradation products have been detected along the study.


Assuntos
Herbicidas , Poluentes Químicos da Água , Herbicidas/química , Éteres Fenílicos/análise , Água/análise , Poluentes Químicos da Água/análise
12.
Sci Total Environ ; 864: 161131, 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36566864

RESUMO

In this work, we have studied the main species involved in determining total dissolved nitrogen (TDN) in water samples for accommodating a variety of quantitation methodologies to portable instruments and with the goal to achieve in situ analysis. The rise of water eutrophication is becoming an ecological problem in the world and TDN contributes markedly to this. Traditionally the several forms of DN are measured in the laboratory using conventional instrumentation from grab samples, but their analysis in place and in real time is a current demand. Inorganic nitrogen: NO3-, NO2- and NH4+, and organic nitrogen, such as amino nitrogen were tested here. For nitrate that presents native UV absorption suitable for direct water analysis, a portable optical fiber probe was compared with benchtop equipment and an in place analyzer. For nitrate, nitrite and ammonium, in situ solid devices that deliver reagents needed were tested and water color was measured by a smartphone coupled with a miniaturized optical fiber spectrometer and a miniaturized spectrometer or from images obtained and their RGB components. Amino nitrogen of some aromatic aminoacids with native fluorescence was followed by a portable optical fiber probe. Organic amino nitrogen and ammonium were determined by a portable luminometer and luminol supported in a measurement tube. Moreover, a portable miniaturized liquid chromatograph was shown suitable for monitoring priority nitrogen environmental pollutants. All options provided suitable results in comparison with lab estimations and were useful for evaluating if the legislation is fulfilled for the variety of tested waters. A discussion about the several portable options proposed for in place analysis, in function of the legislated determinations needed for each type of water was carried out.

13.
Sci Rep ; 13(1): 7759, 2023 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-37173325

RESUMO

Recent advances in machine learning research, combined with the reduced sequencing costs enabled by modern next-generation sequencing, paved the way to the implementation of precision medicine through routine multi-omics molecular profiling of tumours. Thus, there is an emerging need of reliable models exploiting such data to retrieve clinically useful information. Here, we introduce an original consensus clustering approach, overcoming the intrinsic instability of common clustering methods based on molecular data. This approach is applied to the case of non-small cell lung cancer (NSCLC), integrating data of an ongoing clinical study (PROMOLE) with those made available by The Cancer Genome Atlas, to define a molecular-based stratification of the patients beyond, but still preserving, histological subtyping. The resulting subgroups are biologically characterized by well-defined mutational and gene-expression profiles and are significantly related to disease-free survival (DFS). Interestingly, it was observed that (1) cluster B, characterized by a short DFS, is enriched in KEAP1 and SKP2 mutations, that makes it an ideal candidate for further studies with inhibitors, and (2) over- and under-representation of inflammation and immune systems pathways in squamous-cell carcinomas subgroups could be potentially exploited to stratify patients treated with immunotherapy.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Carcinoma Pulmonar de Células não Pequenas/patologia , Neoplasias Pulmonares/patologia , Proteína 1 Associada a ECH Semelhante a Kelch , Consenso , Fator 2 Relacionado a NF-E2 , Análise por Conglomerados
14.
Anal Chem ; 84(16): 7233-40, 2012 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-22861152

RESUMO

We report a new in-tube solid phase microextraction approach named magnetic in-tube solid phase microextraction, magnetic-IT-SPME. Magnetic-IT-SPME has been developed, taking advantage of magnetic microfluidic principles with the aim to improve extraction efficiency of IT-SPME systems. First, a magnetic hybrid material formed by Fe(3)O(4) nanoparticles supported on SiO(2) was synthesized and immobilized in the surface of a bared fused silica capillary column to obtain a magnetic adsorbent extraction phase. The capillary column was placed inside a magnetic coil that allowed the application of a variable magnetic field. Acetylsalicylic acid, acetaminophen, atenolol, diclofenac, and ibuprofen were tested as target analytes. The application of a controlled magnetic field resulted in quantitative extraction efficiencies of the target analytes between 70 and 100%. These results demonstrated that magnetic forces solve the low extraction efficiency (10-30%) of IT-SPME systems, which is one of their main drawbacks.

15.
Talanta ; 245: 123449, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-35429829

RESUMO

In recent years, there is a growing demand for optical sensors given their analytical properties, and the possibility of in situ implementation. Among all the types of optical sensors, plasmonic sensors have aroused great interest in the scientific community. In this work, the ability of a plasmonic sensor based on AgNPs retained on a Nylon surface is studied to determine hydrogen sulfide, which can be an indicator of oral diseases. This compound produces a color change of the sensor from yellow to brown directly related to its concentration. The sensor response is evaluated in two different assay formats such as bag and well microplates. The figures of merits of both methodologies have been obtained and compared. The advantages and disadvantages of the different formats have been shown. Finally, the sensor is applied to quantify sulfides in real saliva. Concentrations ranged from 30 µ L-1 to 600 µ L-1 have been obtained for the voluntaries. Besides that, in this approach the RGB coordinates from images have been used as analytical signal too. The results achieved have demonstrated that the sensor and the methodology applied provide good selectivity, sensibility, rapidity, it is non-invasive and it can be used as indirect method to measure problems in the oral cavity.


Assuntos
Sulfeto de Hidrogênio , Colorimetria , Nylons , Saliva , Sulfetos
16.
J Chromatogr A ; 1664: 462770, 2022 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-34979283

RESUMO

In this study three miniaturized liquid chromatography (LC) instruments have been evaluated and compared for the analysis of caffeine in dietary supplements, namely a benchtop capillary LC (capLC) system, a benchtop nano LC (nanoLC)system and a portable LC system. Commercial products derived from different sources of caffeine have been analyzed. Under optimized conditions, the methods based on benchtop systems were superior in terms of sensitivity. The limits of detection (LODs) found with the capLC and nanoLC systems were 0.01 and 0.003 µg mL-1, respectively, whereas the LOD obtained with the portable LC instrument was of 1 µg mL-1. The portable LC-based method was superior in terms of simplicity and throughput (total analysis time < 15 min). On the basis of the results obtained, a new method for the rapid measurement of caffeine in dietary supplements by portable miniaturized LC is presented. This method provided good linearity within the 1-20 µg mL-1 interval, and it allowed the quantification of caffeine even in products derived from decaffeinated green coffee extracts. The contents of caffeine found with the proposed portable LC method in the real samples analyzed ranged from 1.38 to 7 mg per gram of product, which were values statistically equivalent to those found with the benchtop capLC and nanoLC methods, being the precision, expressed as relative standard deviation (RDS), of 2 -14% (n = 3). The proposed portable LC based method can be used as a simple and rapid alternative to estimate the quality, effectiveness and safety of dietary supplements, regarding their caffeine content.


Assuntos
Cafeína , Suplementos Nutricionais , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida , Suplementos Nutricionais/análise , Limite de Detecção
17.
J Chromatogr A ; 1673: 463119, 2022 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-35550980

RESUMO

Solving and/or evaluating given problems or decision making in place and in real time is a goal of the analytical chemistry science. In this context, the performance of a commercial portable miniaturized liquid chromatograph (minLC) with LED UV (255 nm) detector was compared with those provided by two lab minLCs (capillary and nano) coupled on-line to in-valve in-tube solid phase microextraction (IT-SPME) with diode array detector (DAD). In addition, responses of the portable LC for in-field analysis in several conditions were tested. Besides, two evaluation tools, BETTER criteria for portability and HEXAGON pictogram for sustainability and greenness were applied for comparison purposes. The benchtop LCs provided lower limits of detection (LODs) as expected, in the order of low µg L-1, than those achieved by the portable LC, with LODs around mg L-1 for compounds covering several polarities (logKow between -1.72 and 3.82). The used portable LC gave excellent resolution, reducing the analysis time and being the consumption of solvents negligible. As a practical application, fruit washing residual waters, which contained a suitable level of concentrations of several biocides for employing the portable minLC, were analyzed and quantified from the three minLCs as a proof of concept with comparable results.


Assuntos
Desinfetantes , Águas Residuárias , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida/métodos , Limite de Detecção , Microextração em Fase Sólida/métodos
18.
Anal Chim Acta ; 1223: 340196, 2022 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-35999003

RESUMO

The standard method for estimating the chemical oxygen demand (COD) of water bodies uses dichromate as the main oxidant, a chemical agent whose use has been restricted in the European Union since 2017. This method is hazardous, time-consuming, and burdensome to adapt to on-site measurements. As an alternative and following the current trends of sustainable and green chemistry, a method using the less toxic reagent sodium persulfate as the oxidizing agent has been developed. In this method an excess of persulfate, activated through heating in an alkaline solution, oxidizes the chemically degradable organic fraction through a 2-step radical mechanism. The remaining persulfate is evaluated by chemiluminescence (CL) using luminol and a portable charge-coupled device (CCD) camera. The method provided quantitative recoveries and a sample throughput of >60 samples h-1. It was validated in river water samples by comparison of COD estimations with the standard dichromate method (R = 0.973, p < 0.05) and with a UV-Vis permanganate-based method (R = 0.9998, p < 0.05), the latter being also used for drinking waters. The proposed method is a sustainable and green alternative to the previous used methods. Overall, the method using activated persulfate is suitable for use as COD quantitation/screening tool in surface waters. Considering that its main components are portable, it can be ultimately adapted for in situ analysis at the point of need.


Assuntos
Água Doce , Luminol , Análise da Demanda Biológica de Oxigênio , Água Doce/análise , Oxirredução , Oxigênio/análise , Água/análise
19.
Sci Total Environ ; 805: 150317, 2022 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-34818774

RESUMO

This paper shows a particular example to move to a sustainable circular economical process from valorization of rice straw ashes by developing a green synthesis for obtaining a useful sub-product. This strategy can palliate negative effects of the agriculture waste practices on the environment and also the obtained silica reduced nitrate content in waters. It is demonstrated that the silica synthesis developed at lab was scalable more than a hundred times with good results. Adsorption studies of nitrate in standards and real well waters at lab scale and scaling-up provided similar results. Adsorption values near to 15 mg/g for nitrate standards and 8.5 mg/g for well water were obtained until achieving the initial nitrate concentration. Experimental breakthrough curves fitted to Thomas model, which gave similar results for adsorption capacities. The adsorption capacity was checked with that obtained by a commercial resin, providing improved results. The method at large scale was compared with industrial traditional methods and green adsorbents.


Assuntos
Oryza , Poluentes Químicos da Água , Purificação da Água , Adsorção , Cinética , Nitratos , Dióxido de Silício , Poluentes Químicos da Água/análise
20.
Talanta ; 232: 122406, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34074397

RESUMO

Scopolamine (SCP) is often involved in sexual assaults and robberies, particularly in recreational environments. Therefore, analytical tools are required for the analysis of this compound amenable for the field. In this work, a sensor for SCP is described based on the entrapment of KMnO4 into polydimethylsiloxane (PDMS). The possibility of using KMnO4 in combination with the reagent 1,2-naphtoquinone-4-sulfonate (NQS) giving a double sensor acting as a bicolorimetric device is also demonstrated. In contact with the sample, the PDMS composite delivers MnO4-, which reacts rapidly with SCP under basic conditions causing a change of the color of the solution that can be related to the concentration of drug using both, absorbances and color coordinates, while the NQS part of the sensor remains unchanged. After an exposure time to the sensors of 10 min, satisfactory linearity was obtained for concentrations of SCP up to 865 µg/mL, being the limit of detection (LOD) 108 µg/mL. A method using a portable nano liquid chromatograph with detection at 255 nm has been also developed; in this case the LOD was 100 µg/mL and the working linear interval was 250-2000 µg/mL. The precision, expressed as relative standard deviation (RDS), was ≤8% for both methods. Different beverages (cola, cola-whisky, tonic water-vodka, red wine and green tea) were assayed. The potential of the two proposed approaches for on-site tests is discussed.


Assuntos
Bebidas , Escopolamina , Bebidas Gaseificadas , Cromatografia Líquida , Chá
SELEÇÃO DE REFERÊNCIAS