Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Nat Commun ; 15(1): 4017, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38740759

RESUMO

Ultrasound-driven bioelectronics could offer a wireless scheme with sustainable power supply; however, current ultrasound implantable systems present critical challenges in biocompatibility and harvesting performance related to lead/lead-free piezoelectric materials and devices. Here, we report a lead-free dual-frequency ultrasound implants for wireless, biphasic deep brain stimulation, which integrates two developed lead-free sandwich porous 1-3-type piezoelectric composite elements with enhanced harvesting performance in a flexible printed circuit board. The implant is ultrasonically powered through a portable external dual-frequency transducer and generates programmable biphasic stimulus pulses in clinically relevant frequencies. Furthermore, we demonstrate ultrasound-driven implants for long-term biosafety therapy in deep brain stimulation through an epileptic rodent model. With biocompatibility and improved electrical performance, the lead-free materials and devices presented here could provide a promising platform for developing implantable ultrasonic electronics in the future.


Assuntos
Estimulação Encefálica Profunda , Tecnologia sem Fio , Estimulação Encefálica Profunda/instrumentação , Estimulação Encefálica Profunda/métodos , Animais , Tecnologia sem Fio/instrumentação , Ratos , Eletrodos Implantados , Epilepsia/terapia , Masculino , Próteses e Implantes , Ratos Sprague-Dawley , Transdutores , Desenho de Equipamento , Ondas Ultrassônicas
2.
Mater Horiz ; 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38919990

RESUMO

High-precision neural recording plays a pivotal role in unraveling the intricate mechanisms that underlie information transmission of the nervous system, raising increasing interest in the development of implantable microelectrode arrays (MEAs). The challenge lies in providing a truly soft, highly conductive and low-impedance neural interface for precise recording of the electrophysiological signals of individual neurons or neural networks. Herein, by implementing a novel topological regulation strategy of silk fibroin (SF) crosslinking, we prepared a flexible, hydrophilic, and biocompatible MEA substrate, facilitating a biocompatible neural interface that minimizes mechanical mismatch with biological tissues. Additionally, we established a strategy involving screen-printing combined with post-coating to prepare MEAs with high conductivity, low impedance and high capacitance, by coating PEDOT:PSS on titanium carbide (Ti3C2) microarrays. The Ti3C2 nanosheets, as the conductive track of the MEAs, avoided the charge drifting associated with metals and facilitated the processing of the MEAs. Further coating PEDOT:PSS on the electrode points reduced the impedance 100-fold, from 105 to 103 Ω. Experimental validation confirmed the superior electrophysiological signal recording capabilities of the SF-based MEA (SMEA) in peripheral and cerebral nerves with a much higher signal-to-noise ratio (SNR) of 20. In particular, we achieved high-precision recording of the action potential (AP) induced by flash visual stimulation, demonstrating high performance in weak signal recording. In summary, the development of SMEA provides a robust foundation for future investigations into the mechanisms and principles of neural circuit information transmission in complex nervous systems.

3.
Acta Biomater ; 184: 114-126, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38942188

RESUMO

Inspired by the strong light absorption of carbon nanotubes, we propose a fabrication approach involving one-dimensional TiO2/Bi2S3 QDs nanotubes (TBNTs) with visible red-light excitable photoelectric properties. By integrating the construction of heterojunctions, quantum confinement effects, and morphological modifications, the photocurrent reached 9.22 µA/cm2 which is 66 times greater than that of TiO2 nanotubes (TNTs). Then, a red light-responsive photoelectroactive hydrogel dressing (TBCHA) was developed by embedding TBNTs into a collagen/hyaluronic acid-based biomimetic extracellular matrix hydrogel with good biocompatibility, aiming to promote wound healing and skin function restoration. This approach is primarily grounded in the recognized significance of electrical stimulation in modulating nerve function and immune responses. Severe burns are often accompanied by extensive damage to epithelial-neural networks, leading to a loss of excitatory function and difficulty in spontaneous healing, while conventional dressings inadequately address the critical need for nerve reinnervation. Furthermore, we highlight the remarkable ability of the TBCHA photoelectric hydrogel to promote the reinnervation of nerve endings, facilitate the repair of skin substructures, and modulate immune responses in a deep burn model. This hydrogel not only underpins wound closure and collagen synthesis but also advances vascular reformation, immune modulation, and neural restoration. This photoelectric-based therapy offers a robust solution for the comprehensive repair of deep burns and functional tissue regeneration. STATEMENT OF SIGNIFICANCE: We explore the fabrication of 1D TiO2/Bi2S3 nanotubes with visible red-light excitability and high photoelectric conversion properties. By integrating heterojunctions, quantum absorption effects, and morphological modifications, the photocurrent of TiO2/Bi2S3 nanotubes could reach 9.22 µA/cm², which is 66 times greater than that of TiO2 nanotubes under 625 nm illumination. The efficient red-light excitability solves the problem of poor biosafety and low tissue penetration caused by shortwave excitation. Furthermore, we highlight the remarkable ability of the TiO2/Bi2S3 nanotubes integrated photoelectric hydrogel in promoting the reinnervation of nerve endings and modulating immune responses. This work proposes an emerging therapeutic strategy of remote, passive electrical stimulation, offering a robust boost for repairing deep burn wounds.


Assuntos
Queimaduras , Hidrogéis , Nanotubos , Titânio , Titânio/química , Hidrogéis/química , Nanotubos/química , Animais , Queimaduras/patologia , Queimaduras/terapia , Luz , Epiderme , Cicatrização/efeitos dos fármacos , Camundongos , Masculino
4.
Regen Biomater ; 11: rbad109, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38404618

RESUMO

Lipid droplets (LDs) participating in various cellular activities and are increasingly being emphasized. Fluorescence imaging provides powerful tool for dynamic tracking of LDs, however, most current LDs probes remain inconsistent performance such as low Photoluminescence Quantum Yield (PLQY), poor photostability and tedious washing procedures. Herein, a novel yellow-emissive carbon dot (OT-CD) has been synthesized conveniently with high PLQY up to 90%. Besides, OT-CD exhibits remarkable amphiphilicity and solvatochromic property with lipid-water partition coefficient higher than 2, which is much higher than most LDs probes. These characters enable OT-CD high brightness, stable and wash-free LDs probing, and feasible for in vivo imaging. Then, detailed observation of LDs morphological and polarity variation dynamically in different cellular states were recorded, including ferroptosis and other diseases processes. Furthermore, fast whole imaging of zebrafish and identified LD enrichment in injured liver indicate its further feasibility for in vivo application. In contrast to the reported studies to date, this approach provides a versatile conventional synthesis system for high-performance LDs targeting probes, combing the advantages of easy and high-yield production, as well as robust brightness and stability for long-term imaging, facilitating investigations into organelle interactions and LD-associated diseases.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA