Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Ann Noninvasive Electrocardiol ; 20(1): 43-52, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25546696

RESUMO

BACKGROUND: The present analysis aimed to estimate the penetration of cardiac resynchronization therapy (CRT) on the basis of the prevalence and incidence of eligible patients in selected European countries and in Israel. METHODS AND RESULTS: The following countries were considered: Italy, Slovakia, Greece, Israel, Slovenia, Serbia, the Czech Republic, Poland, Romania, Hungary, Ukraine, and the Russian Federation. CRT penetration was defined as the number of patients treated with CRT (CRT patients) divided by the prevalence of patients eligible for CRT. The number of CRT patients was estimated as the sum of CRT implantations in the last 5 years, the European Heart Rhythm Association (EHRA) White Book being used as the source. The prevalence of CRT indications was derived from the literature by applying three epidemiologic models, a synthesis of which indicates that 10% of heart failure (HF) patients are candidates for CRT. HF prevalence was considered to range from 1% to 2% of the general population, resulting in an estimated range of prevalence of CRT indication between 1000 and 2000 patients per million inhabitants. Similarly, the annual incidence of CRT indication, representing the potential target population once CRT has fully penetrated, was estimated as between 100 and 200 individuals per million. The results showed the best CRT penetration in Italy (47-93%), while in some countries it was less than 5% (Romania, Russian Federation, and Ukraine). CONCLUSION: CRT penetration differs markedly among the countries analyzed. The main barriers are the lack of reimbursement for the procedure and insufficient awareness of guidelines by the referring physicians.


Assuntos
Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Disparidades em Assistência à Saúde/estatística & dados numéricos , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Europa (Continente)/epidemiologia , Humanos , Incidência , Israel/epidemiologia , Prevalência , Resultado do Tratamento
2.
J Am Coll Cardiol ; 5(5): 1212-9, 1985 May.
Artigo em Inglês | MEDLINE | ID: mdl-3989134

RESUMO

This study was carried out to further elucidate the effects of adenosine and adenosine-5'-triphosphate (ATP) on atrioventricular (AV) conduction in patients. Adenosine (0.24 mg/kg) and ATP (0.28 mg/kg) were administered intravenously to 37 patients undergoing intracardiac electrophysiologic evaluation. Both adenosine and ATP depressed AV conduction by lengthening the atrial to His bundle (AH) interval. The effects of adenosine and ATP after rapid intravenous bolus administration were fast in onset (15 +/- 0.5 and 15 +/- 1.5 s, respectively), but transient in duration (10.5 +/- 0.5 s for ATP and 17 +/- 3 s for adenosine). Although muscarinic blockade with 0.04 mg/kg atropine shortened the AH interval from a control value of 123 +/- 12 to 74 +/- 4 ms, it did not modify the effects of adenosine or ATP, or both (that is, latency and duration of the effects were not significantly different from before atropine administration). In contrast, aminophylline, a competitive antagonist of adenosine, completely prevented the effects of adenosine and ATP. Aminophylline alone also shortened the AH interval from a control value of 98 +/- 9 to 74 +/- 9 ms. This decrease was blocked by propranolol (0.1 mg/kg), whereas propranolol did not influence the ability of aminophylline to antagonize the effects of adenosine or ATP, or both. Thus, the catecholamines released by aminophylline are unlikely to account for the ability of aminophylline to antagonize the effects of adenosine and ATP. In conclusion, these findings indicate that intravenously administered adenosine and ATP are equally effective in producing AV block that is antagonized by aminophylline but not by atropine.


Assuntos
Trifosfato de Adenosina/farmacologia , Adenosina/farmacologia , Nó Atrioventricular/efeitos dos fármacos , Sistema de Condução Cardíaco/efeitos dos fármacos , Adenosina/antagonistas & inibidores , Trifosfato de Adenosina/antagonistas & inibidores , Adulto , Aminofilina/farmacologia , Nó Atrioventricular/fisiopatologia , Atropina/farmacologia , Fascículo Atrioventricular/efeitos dos fármacos , Fascículo Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial , Eletrocardiografia , Feminino , Bloqueio Cardíaco/induzido quimicamente , Bloqueio Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade
3.
J Am Coll Cardiol ; 5(5): 1188-97, 1985 May.
Artigo em Inglês | MEDLINE | ID: mdl-3989131

RESUMO

Two-dimensional echocardiography was performed at rest and during rapid transesophageal atrial pacing in 85 patients undergoing coronary arteriography for evaluation of chest pain. Transesophageal atrial pacing was performed with 10 ms pulses of 6 to 27 mA intensity; the rate was progressively increased up to 150 beats/min. Four patients were excluded: two because atrial capture was not achieved and two because of chest discomfort induced during transesophageal atrial pacing. Of the remaining 81 patients, 56 had significant coronary artery disease (greater than or equal to 75% stenosis of at least one major coronary vessel) and 25 had no significant coronary artery disease; 25 of the 56 patients with coronary artery disease had no wall motion abnormalities at rest. The test was considered positive if wall motion abnormalities were detected during pacing. Wall motion abnormalities occurred in 3 of 25 patients without coronary artery disease (specificity 88%) and in 51 of 56 patients with coronary artery disease (sensitivity 91%). Wall motion abnormalities developed in 20 of the 25 patients with coronary artery disease and normal regional wall motion at rest (sensitivity 80%); sensitivity for one, two and three vessel disease was 85% (17 of 20 patients), 94% (15 of 16 patients) and 95% (19 of 20 patients), respectively. In patients without coronary artery disease, wall motion score was 18 at rest and 17.7 +/- 0.9 during pacing (p = NS). In patients with coronary artery disease, wall motion score decreased from 15.2 +/- 3.6 at rest to 11.6 +/- 4.1 during pacing (p less than 0.001). In patients with coronary artery disease and normal regional wall motion at rest, wall motion score decreased from 18 at rest to 14.4 +/- 3.1 during pacing (p less than 0.001). Thus, two-dimensional echocardiography during transesophageal atrial pacing appears both sensitive and specific in detecting patients with coronary artery disease. This new procedure is a feasible and reliable alternative to exercise two-dimensional echocardiography.


Assuntos
Estimulação Cardíaca Artificial , Doença das Coronárias/diagnóstico , Ecocardiografia , Adulto , Idoso , Estimulação Cardíaca Artificial/métodos , Doença das Coronárias/fisiopatologia , Eletrocardiografia , Esôfago , Teste de Esforço , Feminino , Átrios do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica
4.
Am J Cardiol ; 78(5A): 98-101, 1996 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-8820843

RESUMO

A 41-year-old man was hospitalized for syncopal sustained ventricular tachycardia with left bundle branch morphology. Diagnostic screening confirmed a right ventricular dysplasia: fibrofatty replacement of myocardium on endomyocardial biopsy and severe dilation of right ventricle with no left ventricular impairment was documented. His bundle recording showed an abnormally long HV interval, and programmed ventricular stimulation induced high-rate sustained ventricular tachycardia with left bundle branch block morphology associated with reduced systolic blood pressure and dizziness. Right ventricular burst pacing proved to be effective in restoring sinus rhythm. A single lead pectoral cardioverter-defibrillator was implanted and programmed for VVI and antitachycardia pacing, as first ventricular tachycardia therapeutic intervention. During 6-month follow-up, 1 asymptomatic ventricular tachycardia recurrence terminated by antitachycardia pacing was reported by the device. The possible role of the other therapeutic options such as drugs, ablation, and surgery for this specific case is also discussed.


Assuntos
Cardiomiopatias/complicações , Síncope/complicações , Taquicardia Ventricular/complicações , Adulto , Bloqueio de Ramo/complicações , Bloqueio de Ramo/diagnóstico , Cardiomiopatias/diagnóstico , Desfibriladores Implantáveis , Ventrículos do Coração , Humanos , Masculino , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Disfunção Ventricular Direita/complicações , Disfunção Ventricular Direita/diagnóstico
5.
Am J Cardiol ; 86(9): 959-63, 2000 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-11053707

RESUMO

Time- and frequency-domain analysis of heart rate variability (HRV) has been proven effective in describing alteration of autonomic control mechanisms and in identifying patients with increased cardiac and arrhythmic mortality. Patients with implantable cardioverter defibrillators offer the opportunity to evaluate HRV patterns before ventricular tachycardia (VT) and under control conditions. We therefore analyzed time- and frequency-domain parameters of short-term HRV and power-law behavior of RR interval time series at rest, at 15 to 30 minutes, and immediately before VT. In comparison to control conditions, lower values of mean cycle length duration and total power were observed before VT. Spectral analysis indicated that the low- to high-frequency ratio was significantly higher (5.5 +/- 0.6 vs 2.8 +/- 0.3) immediately before VT than during rest. Both findings were consistent with the shift of sympathovagal balance toward sympathetic predominance and reduced vagal tone. Before VT, a more negative value of the scaling exponent beta of the power-frequency relation (-1.57 +/- 0.04 vs -1.33 +/- 0.04) also confirmed the presence of an altered HRV pattern in comparison to controls. Thus, both abnormal autonomic modulation and dynamic patterns of HRV seem to characterize the minutes before arrhythmia onset in these patients.


Assuntos
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Eletrocardiografia , Taquicardia Ventricular/diagnóstico , Idoso , Análise de Variância , Arritmias Cardíacas/complicações , Sistema Nervoso Autônomo/fisiopatologia , Eletrocardiografia Ambulatorial , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Probabilidade , Valores de Referência , Taxa de Sobrevida , Taquicardia Ventricular/complicações , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/terapia , Resultado do Tratamento
6.
Int J Cardiol ; 30(2): 209-14, 1991 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-2010244

RESUMO

Electrophysiologic intracardiac and noninvasive transesophageal testing, used to evaluate parameters of anterograde conduction across the accessory pathway, the refractory period and shortest atrial cycle length with 1:1 conduction over the pathway, were compared to assess the reliability of the noninvasive technique in identifying patients with Wolff-Parkinson-White syndrome, at risk of rapid ventricular response during atrial fibrillation when this arrhythmia is not inducible. Sixteen patients with Wolff-Parkinson-White syndrome were submitted both to invasive and transesophageal atrial stimulation. We evaluated both the functional and effective refractory periods of the accessory pathway, using the same drive cycle length, and the shortest cycle length with 1:1 atrioventricular conduction over the accessory pathway. There were no differences between the parameters obtained by intracardiac atrial stimulation and by transesophageal atrial stimulation. The two approaches correlated well: mean functional refractory periods of the accessory pathway were 285 +/- 42 msec and 289 +/- 32 msec, respectively (NS, r = 0.88); mean effective refractory periods of the accessory pathway were 267 +/- 41 msec and 271 +/- 32 msec, respectively (NS, r = 0.89); mean shortest cycle lengths with 1:1 conduction over the accessory pathway were 255 +/- 48 msec and 255 +/- 44 msec, respectively (NS, r = 0.94). These data demonstrate the reliability of transesophageal atrial stimulation in estimating the parameters for anterograde conduction across an accessory pathway. These results, and the already documented ability of transesophageal atrial stimulation to induce atrial fibrillation, suggest this noninvasive technique should be taken as a first approach in screening patients with Wolff-Parkinson-White syndrome.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Estimulação Cardíaca Artificial/métodos , Sistema de Condução Cardíaco/fisiopatologia , Síndrome de Wolff-Parkinson-White/diagnóstico , Adulto , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Morte Súbita/epidemiologia , Eletrocardiografia , Eletrofisiologia , Feminino , Átrios do Coração , Humanos , Masculino , Fatores de Risco , Síndrome de Wolff-Parkinson-White/fisiopatologia
7.
Int J Cardiol ; 22(2): 177-83, 1989 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-2914741

RESUMO

The acute electrophysiological effects of intravenous nicardipine (0.014 mg/kg per min for 5 minutes) were studied in 12 subjects with estimated normal sinus node functions and atrioventricular conduction parameters. The most important effects were sinus cycle length shortening, increase of corrected sinus node recovery time and reduction of effective and functional refractory period of the atrioventricular node. Sinuatrial conduction time, atrial refractory periods, intranodal conduction, bundle branch refractoriness and ventricular refractoriness were unchanged. Systolic and diastolic blood pressure was reduced. The clinical implications of these properties of the drug are discussed and compared with those of verapamil, diltiazem and nifedipine.


Assuntos
Eletrocardiografia , Sistema de Condução Cardíaco/efeitos dos fármacos , Nicardipino/administração & dosagem , Pressão Sanguínea/efeitos dos fármacos , Fascículo Atrioventricular/efeitos dos fármacos , Cardiomiopatia Hipertrófica/tratamento farmacológico , Doença das Coronárias/tratamento farmacológico , Átrios do Coração/efeitos dos fármacos , Humanos , Hipertensão/tratamento farmacológico , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Nó Sinoatrial/efeitos dos fármacos
8.
Int J Cardiol ; 30(3): 329-33, 1991 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-2055673

RESUMO

L-propionylcarnitine, a short-chain acylcarnitine, has been shown in experimental studies to induce, during acidic and hypoxic conditions, some electrophysiological changes such as an increase of duration of the action potential and of the effective refractory period. In this study, the acute electrophysiological effects of intravenous L-propionylcarnitine (30 mg/kg in 3 min) were studied in 12 subjects with estimated normal function of the sinus node and normal parameters for atrioventricular conduction. Statistically significant changes were observed 2 min after infusion. The sinus cycle length shortened (866 +/- 138 vs 818 +/- 124 msec, P less than 0.05) while refractory periods of the atrioventricular node increased (effective by 30-50 msec in four cases; functional from 425 +/- 52 to 436 +/- 55 msec, P less than 0.05). Sinuatrial conduction time, atrial refractory periods, infranodal conduction, bundle branch, His-Purkinje system and ventricular refractoriness were unchanged. Systolic and diastolic blood pressure were also unchanged. Because of the limited effects on electrophysiological parameters, L-propionylcarnitine should be used as a metabolic drug even in patients with mild disturbances of conduction.


Assuntos
Carnitina/análogos & derivados , Sistema de Condução Cardíaco/efeitos dos fármacos , Pressão Sanguínea/efeitos dos fármacos , Carnitina/deficiência , Carnitina/farmacologia , Cateterismo Periférico , Eletrofisiologia , Feminino , Átrios do Coração/efeitos dos fármacos , Sistema de Condução Cardíaco/fisiologia , Ventrículos do Coração/efeitos dos fármacos , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Período Refratário Eletrofisiológico/efeitos dos fármacos , Nó Sinoatrial/efeitos dos fármacos , Fatores de Tempo
9.
Int J Cardiol ; 25(2): 213-8, 1989 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-2807610

RESUMO

This report describes the usefulness of transesophageal atrial pacing in the treatment of five patients with hyperkalemia-induced bradycardias. Three patients had marked sinus bradycardia while the other two had a regular rhythm with QRS of left bundle branch block morphology, with no P waves visible on the surface electrocardiogram. Four patients were in chronic hemodialysis three times a week, and one had severe post-traumatic hemorrhage. In three patients, hyperkalemia had been precipitated by food intoxication. In one case the cause was unknown while, in the last case, hyperkalemia was due to rapid infusion of stored blood and solutions containing high concentrations of potassium. Transesophageal atrial pacing was performed in all cases utilizing a bipolar catheter introduced into the esophagus and a constant current generator delivering square wave pulses of 10 msec duration and 19-28 mA intensity. Atrial capture, followed by impulse conduction to the ventricles, was constant in all cases, being performed for between 15 and 35 minutes until a normal sinus rhythm was restored. The procedure was well tolerated. The advantages of this procedure as opposed to invasive ventricular pacing are discussed.


Assuntos
Bradicardia/terapia , Estimulação Cardíaca Artificial , Hiperpotassemia/complicações , Idoso , Bradicardia/etiologia , Bradicardia/fisiopatologia , Eletrocardiografia , Feminino , Frequência Cardíaca , Humanos , Hiperpotassemia/terapia , Masculino , Pessoa de Meia-Idade
10.
Int J Cardiol ; 26(2): 201-9, 1990 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-2303298

RESUMO

The natural evolution of ventricular arrhythmias complicating a first episode of acute myocardial infarction has been studied in a group of 56 consecutive patients, who were admitted to the Coronary Care Unit within three hours of the onset of symptoms, and in whom drug administration (digitalis, antiarrhythmics, diuretics and heparin) was limited. Ventricular arrhythmias have been evaluated by means of Holter monitoring performed during the first 24 hours, the second 24 hours, the eighth day, the 18th day and two years after discharge when antiarrhythmic drugs has been discontinued for at least five half-lives. The overall incidence and prevalence of ventricular arrhythmias showed a steady and statistically significant reduction from the first to the eighth day, and a not statistically significant increase from the eighth to the 18th day. The latter increase was still present at the two-year follow-up. The one-by-one behaviour analysis of discharged patients delineated three different patterns: patients who presented a steady reduction in ventricular arrhythmias from the first to the 18th day (44%); patients who showed an almost constant incidence of ventricular arrhythmias during all phases of acute myocardial infarction (24%); and patients who presented both a decrease and an increase in their ventricular arrhythmias (31%). The follow-up at two years showed that the majority of patients, especially those discharged in a high Lown class, had the same arrhythmias as at their follow-up on the 18th day. Correlation of ventricular arrhythmias with the extent of the infarcted area demonstrated that only the peak and mean values of lactic dehydrogenase correlated with the severity of ventricular arrhythmias.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Arritmias Cardíacas/complicações , Infarto do Miocárdio/etiologia , Doença Aguda , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/tratamento farmacológico , Arritmias Cardíacas/fisiopatologia , Eletrocardiografia Ambulatorial , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/fisiopatologia
11.
Int J Cardiol ; 28(3): 347-52, 1990 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-2210900

RESUMO

This study was performed to evaluate whether transoesophageal atrial pacing could also stop ventricular tachycardias with low rates and no haemodynamic impairment. Prior to resorting to ventricular endocardial pacing, seven male patients, aged between 15 and 73 years, were treated by transoesophageal atrial pacing for 10 spontaneous episodes of sustained ventricular tachycardia at rates between 105 and 160 beats per minute, without haemodynamic impairment. When atrial pacing did not allow ventricular capture, atropine sulphate was administered. Transoesophageal atrial pacing led to ventricular capture in seven episodes, which made overdriving possible, and blocked six episodes of ventricular tachycardia. In no case did transoesophageal atrial pacing lead to an acceleration of ventricular tachycardia or to degeneration into ventricular fibrillation. Transoesophageal atrial pacing can block low-rate sustained ventricular tachycardias (less than or equal to 150 beats per minute). For low-rate sustained ventricular tachycardias without haemodynamic impairment, transoesophageal atrial pacing can thus be used as the method of choice thanks to its good ratio of risk to efficiency.


Assuntos
Estimulação Cardíaca Artificial/métodos , Taquicardia/terapia , Adolescente , Adulto , Idoso , Eletrocardiografia , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia/fisiopatologia
12.
Acta Cardiol ; 32(2): 105-20, 1977.
Artigo em Inglês | MEDLINE | ID: mdl-302072

RESUMO

The acute electrophysiologic effects of intravenous Bunaphtine 1,5 mg/kg body weight, a new antiarrhythmic drug, were studied in 19 subjects with estimated normal impulse formation and conduction. Significant effects were sinus bradycardia, prolongation of atrial refractory periods, depression of intranodal and infranodal conduction and prolongation of His-Purkinje system refractory periods. These properties are compared with those of amiodarone and quinidine and form the basis for a correct use of Bunaphtine in the management of arrhythmias.


Assuntos
Antiarrítmicos/uso terapêutico , Arritmias Cardíacas/tratamento farmacológico , Naftalenos/uso terapêutico , Adulto , Idoso , Antiarrítmicos/administração & dosagem , Butilaminas/administração & dosagem , Butilaminas/uso terapêutico , Avaliação de Medicamentos , Eletrocardiografia , Humanos , Injeções Intravenosas , Pessoa de Meia-Idade , Naftalenos/administração & dosagem
13.
Int Angiol ; 30(2): 135-9, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21427650

RESUMO

AIM: The purpose of this study was to investigate the feasibility of contrast-enhanced ultrasound (CEUS) in the evaluation of renal artery stenosis as compared with traditional techniques: echo color Doppler (ECD) investigation and selective angiography .CEUS is a technique based on the injection of an intravascular biocompatible tracer, namely an intravenous contrast galactose microparticle suspension containing microbubbles (Levovist), that has a similar rheology to that of red blood cells, allowing quantification of renal tissue perfusion. METHODS: A population of 120 hypertensive patients (82 men, mean age 55) with a systolic abdominal murmur and/or a diagnosis of poly-districtual atherosclerosis was studied by ECD and CEUS (Levovist). Selective angiography was performed in patients with renal artery stenosis demonstrated by one of the two ultrasonographic techniques. RESULTS: Forty of the 120 patients in the study population showed renal artery stenosis at one of the two ultrasound techniques: ECD identified renal artery stenosis in 33 cases and CEUS in 38. Instead, selective angiography had detected renal artery stenosis in 38 patients, the same with renal artery stenosis diagnosed by CEUS. Thus, CEUS sensitivity, specificity and accuracy were similar to those of angiography while six false negatives and two false positives were obtained with ECD. CONCLUSION: Our results suggest that this renal CEUS is a promising, new, non-invasive method for screening patients with suspected renal artery stenosis. This technique appears to be superior to traditional ECD flow imaging for diagnosing renal artery stenosis and so may be an important aid in cardiovascular diagnostics.


Assuntos
Meios de Contraste , Polissacarídeos , Obstrução da Artéria Renal/diagnóstico por imagem , Artéria Renal/diagnóstico por imagem , Ultrassonografia Doppler em Cores , Meios de Contraste/administração & dosagem , Reações Falso-Negativas , Reações Falso-Positivas , Estudos de Viabilidade , Feminino , Humanos , Injeções Intravenosas , Itália , Masculino , Pessoa de Meia-Idade , Polissacarídeos/administração & dosagem , Valor Preditivo dos Testes , Radiografia , Sensibilidade e Especificidade
14.
Infez Med ; 19(4): 207-23, 2011 Dec.
Artigo em Italiano | MEDLINE | ID: mdl-22212160

RESUMO

Cardiac Implantable Electronic Device (CIED) infections are an emerging clinical issue. There are no national recommendations on the management of these infections, also due to the limited number of dedicated and high quality clinical studies. Therefore, researchers from southern Italian centres have decided to share the clinical experience gathered so far in this field and report practical recommendations for the diagnosis and treatment of adult patients with CIED infection or endocarditis. Here we review the risk factors, diagnostic issues (microbiological and echocardiographic) and aetiology, and describe extensively the best therapeutic approach. We also address the management of complications, follow-up after discharge and the prevention of CIED infections. In this regard, a multidisciplinary approach is fundamental to appropriately manage the initial diagnostic process and the comorbidities, to plan proper antimicrobial treatment and complete percutaneous hardware removal, with the key support of microbiology and echocardiography.


Assuntos
Antibacterianos/uso terapêutico , Bacteriemia/tratamento farmacológico , Desfibriladores Implantáveis , Endocardite Bacteriana/tratamento farmacológico , Marca-Passo Artificial , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Estafilocócicas/tratamento farmacológico , Bacteriemia/diagnóstico , Bacteriemia/microbiologia , Desfibriladores Implantáveis/microbiologia , Remoção de Dispositivo , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/microbiologia , Seguimentos , Humanos , Comunicação Interdisciplinar , Marca-Passo Artificial/microbiologia , Guias de Prática Clínica como Assunto , Infecções Relacionadas à Prótese/prevenção & controle , Fatores de Risco , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/etiologia , Resultado do Tratamento
15.
Curr Pharm Des ; 14(26): 2686-92, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19006851

RESUMO

BACKGROUND: It has been suggested that low thyroid hormones levels may be associated with increased mortality in patients with cardiovascular disease. AIM: To evaluate the prognostic role of thyroid function deficiency in patients with chronic heart failure (CHF). METHODS: We evaluated 338 consecutive outpatients with stable CHF receiving conventional therapy, all of whom underwent a physical examination, electrocardiography and echocardiography. Blood samples were drawn to assess renal function, and Na+, hemoglobin, NT-proBNPs, fT3, fT4 and TSH levels. Patients with hyperthyroidism were excluded. RESULTS: During the follow-up (15+/-8 months), heart failure progression was observed in 79 patients (including 18 who died of heart failure after hospitalisation and six who underwent transplantation). Univariate regression analysis showed that TSH (p<0.0001), fT3 (p<0.0001), fT4 (p=0.016) and fT3/fT4 (p<0.0001) were associated with heart failure progression but multivariate analysis showed that only TSH considered as a continuous variable (p = 0.001) as well as subclinical hypothyroidism (TSH > 5.5 mUI/l; p=0.014) remained significantly associated with the events. CONCLUSIONS: In CHF patients TSH levels even slightly above normal range are independently associated with a greater likelihood of heart failure progression. This supports the need for prospective studies aimed at clarifying the most appropriate therapeutic approach to sub-clinical hypothyroidism in such patients.


Assuntos
Insuficiência Cardíaca/fisiopatologia , Hipotireoidismo/diagnóstico , Testes de Função Tireóidea , Tireotropina/sangue , Idoso , Doença Crônica , Progressão da Doença , Ecocardiografia , Eletrocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Humanos , Hipotireoidismo/complicações , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Análise de Regressão , Tiroxina/sangue , Tri-Iodotironina/sangue
16.
Pacing Clin Electrophysiol ; 22(12): 1817-9, 1999 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-10642138

RESUMO

In three patients, two with a pacemaker and one with an implantable cardioverter defibrillator, hospitalized for dislodgement of a passive fixation J-shaped atrial lead, a percutaneous transcatheter repositioning was successfully attempted thus avoiding surgical revision. This procedure, performed through the femoral vein, is easy and safe. The stability of the lead position and of the pacing and sensing parameters was confirmed 1 and 6 months after the transcatheter repositioning.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Cateterismo Cardíaco/instrumentação , Eletrocardiografia Ambulatorial , Desenho de Equipamento , Falha de Equipamento , Feminino , Veia Femoral , Seguimentos , Migração de Corpo Estranho/terapia , Humanos , Masculino , Pessoa de Meia-Idade
17.
Pacing Clin Electrophysiol ; 22(8): 1140-5, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10461288

RESUMO

The decrease of defibrillation energy requirement would render the currently available transvenous defibrillator more effective and favor the device miniaturization process and the increase of longevity. The unipolar defibrillation systems using a single RV electrode and the pectoral pulse generator titanium shell (CAN) proved to be very efficient. The addition of a third defibrillating electrode in the coronary sinus did not prove to offer advantages and in the superior vena cava showed only a slight reduction of the defibrillation threshold (DFT). The purpose of this study was to determine whether the defibrillation efficacy of the single lead unipolar transvenous system could be improved by adding an electrode in the inferior vena cava (IVC). In 17 patients, we prospectively and randomly compared the DFT obtained with a single lead unipolar system with the DFT obtained using an additional of an IVC lead. The RV electrode, Medtronic 6936, was used as anode (first phase of biphasic) in both configurations. A 108 cm2 surface CAN, Medtronic 7219/7220 C, was inserted in a left submuscular infraclavicular pocket and used as cathode, alone or in combination with IVC, Medtronic 6933. The superior edge of the IVC coil was positioned 2-3 cm below the right atrium-IVC junction. Thus, using biphasic 65% tilt pulses generated by a 120 microF external defibrillator, Medtronic D.I.S.D. 5358 CL, the RV-CAN DFT was compared with that obtained with the RV-CAN plus IVC configuration. Mean energy DFTs were 7.8 +/- 3.6 and 4.8 +/- 1.7 J (P < 0.0001) and mean impedance 65.8 +/- 13 O and 43.1 +/- 5.5 O (P < 0.0001) with the RV-CAN and the IVC configuration, respectively. The addition of IVC significantly reduces the DFT of a single lead active CAN pectoral pulse generator. The clinical use of this biphasic and dual pathway configuration may be considered in patients not meeting implant criteria with the single lead or the dual lead RV-superior vena cava systems. This configuration may also prove helpful in the use of very small, low output ICDs, where the clinical impact of ICD generator size, longevity, and related cost may offset the problems of dual lead systems.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Adulto , Idoso , Eletrocardiografia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Músculos Peitorais , Estudos Prospectivos , Implantação de Prótese/métodos , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento , Veia Cava Inferior , Fibrilação Ventricular/fisiopatologia
18.
Eur J Cardiol ; 9(4): 333-42, 1979 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34520

RESUMO

The acute electrophysiologic effects of intravenous Tenormine (0.1 mg/kg body weight), a new cardioselective beta-adrenoreceptor blocking drug, were studied in 18 subjects with estimated normal impulse formation and conduction. The most significant (P less than 0.01) effects were sinus cycle lengthening, depression of intranodal conduction and prolongation of AV node refractory periods. Sinus node recovery time, sinoatrial conduction time and atrial refractory periods were only slightly prolonged (P less than 0.05). Intraatrial conduction and infra-His conduction were unchanged. These properties are compared with those of the most commonly employed beta-blocking agents. The clinical implications are discussed.


Assuntos
Antagonistas Adrenérgicos beta/uso terapêutico , Atenolol/uso terapêutico , Propanolaminas/uso terapêutico , Acetamidas/administração & dosagem , Eletrofisiologia , Feminino , Sistema de Condução Cardíaco/efeitos dos fármacos , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Nó Sinoatrial/efeitos dos fármacos
19.
Cardiologia ; 36(8 Suppl): 71-4, 1991 Aug.
Artigo em Italiano | MEDLINE | ID: mdl-1817774

RESUMO

During recent years criteria for localization of bypass tracts in the Wolff-Parkinson-White syndrome from the conventional ECG have been acquired utilizing epicardial and endocardial mapping data. The polarity of delta wave and QRS in the frontal and horizontal plane and the morphology of retrograde P waves during orthodromic reciprocating tachycardia, are the most indicative elements. An accurate analysis of QRS complexes during atrial fibrillation confirms the site of pre-excitation and could suggest the presence of 2 or more accessory pathways with sufficient spatial separation. Some criteria for identifying multiple accessory pathways are discussed.


Assuntos
Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Síndrome de Wolff-Parkinson-White/diagnóstico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Humanos , Síndrome de Wolff-Parkinson-White/fisiopatologia
20.
Cardiologia ; 36(8 Suppl): 75-80, 1991 Aug.
Artigo em Italiano | MEDLINE | ID: mdl-1817775

RESUMO

Electrophysiologic non-invasive transesophageal testing is compared to intracardiac study in the management of patients with Wolff-Parkinson-White (WPW) syndrome. Transesophageal study can be reliably used to identify the participation of the accessory pathway in reciprocating supraventricular tachycardia and to determine the anterograde conduction properties of the accessory pathway. Using the shortest pre-excited interval during induced atrial fibrillation, or programmed and continuous atrial transesophageal stimulation can markedly reduce the need of intracardiac evaluation. The greater safety and economy of transesophageal compared to the intracardiac technique justify its wider use in preliminary screening of all WPW patients, unless ablative treatment has been clinically indicated, and in evaluating long-term drug protection against a potential deleterious ventricular response during atrial tachyarrhythmias.


Assuntos
Estimulação Cardíaca Artificial , Eletrocardiografia , Síndrome de Wolff-Parkinson-White/diagnóstico , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Síndrome de Wolff-Parkinson-White/fisiopatologia , Síndrome de Wolff-Parkinson-White/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA