RESUMO
PURPOSE: To assess the feasibility and safety of intravascular lithotripsy (IVL) for enabling transfemoral abdominal (EVAR), thoracic (TEVAR), and thoracoabdominal (BEVAR) endovascular aneurysm repair in patients with narrow and calcified iliac arteries. MATERIALS AND METHODS: Consecutive patients treated with IVL for severe calcified and narrowed iliac access before EVAR, TEVAR, or BEVAR between November 2020 and June 2022 were retrospectively evaluated. All anatomical iliac characteristics were acquired by multi-planar reconstruction of preoperative computed tomography angiography (CTA). The hostility of the vascular accesses was classified based on Peripheral Arterial Calcium Scoring System (PACSS) and calcified access severity score (CASS), a new score considering both anatomical (calcium grade and length, minimum lumen diameter [MLD], and tortuosity index) and aortic stent-graft (SG/MLD index) parameters. Primary endpoint was technical success defined as successful aortic endograft delivery and deployment without iliac rupture. Freedom from complications and primary patency were additionally analyzed. RESULTS: Twenty-eight iliac axes were treated with IVL (8 bilateral) in 20 patients (mean age 74.5±6.7 years) with a mean follow-up of 26.5±6.2 (range 17-36) months. Ten patients underwent EVAR: 3 TEVAR, and 7 BEVAR procedures. In 14 patients (70%), aneurysm disease was associated with symptomatic aorto-iliac occlusive disease (AIOD), with Rutherford class III to IV. The PACSS was grade IV in 89% of the cases and the CASS (mean 14±2) was grade III to IV in all cases. The stent-graft (SG) outer diameter (5.60±1.65 mm) was significantly larger by 50% than MLD (3.96±1.20 mm), with an SG/MLD index of 1.50±0.51 (p<0.001). Technical success was 100%. No dissection, rupture, or distal embolization occurred. One (3.4%) bail-out stenting was necessary as endoconduit after IVL treatment. One month CTA showed that postoperative luminal gain increased by 93% (p<0.001). An improvement of 2 Rutherford classes occurred in all AIOD patients with a primary patency of 100% at last follow-up. CONCLUSIONS: This study shows the safety and feasibility of IVL as a valuable option to treat narrow and calcified iliac arteries to facilitate endograft delivery. Further studies will be useful to confirm these results. CLINICAL IMPACT: In this article, the use of intravascular iliac artery lithotripsy to facilitate aortic endograft delivery is explored. The presence of iliac severe calcifications still represents a contraindication for aortic endovascular repair. Intravascular lithotripsy increases the feasibility and safety of endovascular aortic procedures, facilitating endograft delivery and reducing the risk of iliac rupture and/or dissections by improving vessel compliance and luminal gain. This novel vessel preparation could be an alternative to "paving and cracking" and/or iliac conduits. This study describes a new score to classify the severity of iliac calcifications, considering anatomical parameters and the profile of aortic endografts delivery system.
RESUMO
PURPOSE: This article aims at investigating the outcomes of percutaneous access via the first versus third axillary artery (AXA) segments with closure devices during aortic procedures. MATERIALS AND METHODS: All patients receiving percutaneous AXA access closed with Perclose ProGlide device (Abbott, Santa Clara, California) from 2008 to 2021 were included in a retrospective multicenter registry (NCT: 04589962). Efficacy endpoint was the technically successful percutaneous procedure (no open conversion). Safety endpoints were stroke and access complications according to the Valve Academic Research Consortium-3 reporting standards. The first (AXA1) or third (AXA3) axillary puncture sites were compared. RESULTS: A total of 412 percutaneous AXA accesses were included: 172 (42%) in AXA1 and 240 (58%) in AXA3. Left AXA was catheterized in 363 cases (76% of AXA1 vs 97% of AXA3, p<0.001) and 91% of fenestrated/branched endovascular repair (F/BEVAR) procedures were conducted from the left. A ≥12F internal diameter (ID) sheath was used in 49% of procedures. Open conversion rate was 1%, no major vascular complications occurred, and only one major non-vascular complication was recorded. Primary closure failure occurred in 18 AXA1 (11%) and 32 AXA3 accesses (13%), treated by covered (8.3%) or bare-metal (2.7%) stenting. Bailout stent patency was 100% at median follow-up of 12 months, with 6 of 6 stents still patent after >36 months of follow-up. Stroke rate was 4.4%. An introducer sheath >12F was independently associated with both access complications (p<0.001) and stroke (p=0.005), while a right-side access was associated with stroke only (p=0.034). Even after adjustment for covariates, AXA1 versus AXA3 showed an equal success rate (odds ratio [OR]=0.537, 95% confidence interval [CI]=0.011-1.22 for AXA3, p=0.104). The combination of AXA3 and a >10F introducer sheath provided worse outcomes compared with >10F sheaths through AXA1 (OR for success=0.367, 95% CI=0.176-0.767, p=0.008). This was not confirmed for >12F sheaths, associated with similar outcomes (p=0.31 AXA 1 vs AXA 3). CONCLUSION: Major local complications with the percutaneous axillary approach and ≤12F sheaths are infrequent and solvable by complementary endovascular interventions. Stroke risk remains an issue. First and third AXA segments are both amenable for access with good results, but larger sheaths (12F) perform better in AXA1. CLINICAL IMPACT: Percutaneous access with vascular closure devices at the first or third axillary artery (AXA) segments during aortic procedures is burdened by a negligible risk of open conversion. Local complications with the percutaneous axillary approach are infrequent and solvable by complementary endovascular interventions. First and third AXA segments are both amenable to access with excellent results, but larger sheaths (12F) perform better in the wider first AXA segment. In this setting, bailout stenting does not appear to be associated with mid-term stent occlusion.
RESUMO
PURPOSE: Chimney endovascular abdominal aortic aneurysm repair (CHEVAR) has predominantly been described as an alternative technique for the management of urgent presentations of degenerative pararenal aortic aneurysms (dPAAs). However, the role of CHEVAR in the treatment of asymptomatic patients remains unknown. The aim of current multinational study was to evaluate the outcomes of elective CHEVAR of dPAAs. MATERIAL AND METHODS: Retrospective analysis of 267 consecutive dPAA patients treated with elective CHEVAR at 13 European and US centers from 2008 to 2014. Primary endpoints were 30 days and out of hospital CHEVAR-related mortality. Secondary endpoints included persistent type Ia endoleak or endotension, angiographically confirmed occlusion and/or high-grade chimney graft (CG) or involved splanchnic vessel stenosis identified at index procedure and/or during follow-up, as well as CHEVAR-related re-intervention. RESULTS: Mean follow-up time was 25.5±13.3 months. The 442 visceral vessels were involved and mean number of CGs per patient was 1.63±0.7. 436 targeted vessels were successfully cannulated. The aortic graft intentionally covered 6 renal arteries and immediate technical success was 98.6%. The 30 days mortality was 1.9% (n=5), while the in-hospital complication rate was 10.1% (n=27) including 3 strokes, 1 permanent dialysis, and 1 intestinal ischemia. No 30 day type Ia endoleaks were detected and 3.2% of CGs (n=14, including the intentionally covered) had evidence of occlusion and/or stenosis. The overall CHEVAR-related mortality was 2.2% (n=6). Freedom from primary and secondary type Ia endoleak/endotension rates at 3 years was 93.0% and 98.0%, respectively. Primary and secondary CG patency was 87.0% and 89.0%. Primary and secondary endovascular freedom from any endpoint at 3 years was 81.0% and 94.0% respectively. CONCLUSION: Elective use of CHEVAR in the management of dPAAs seems to be durable. These results are comparable to published outcomes with other total endovascular strategies, which justifies an expanded role for CHEVAR in the treatment of asymptomatic patients presenting with dPAAs.
Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Humanos , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Stents , Resultado do TratamentoRESUMO
OBJECTIVE: Recent guidelines recognize the role of chimney endovascular aneurysm repair (ChEVAR) in the treatment of complex aortic disorders. The optimal configuration and number of visceral vessels that can be incorporated is still controversial. We aim to review outcomes from a multi-institutional decade-long experience with ChEVAR. METHODS: Patients undergoing ChEVAR with multiple (≥2) chimney branches were selected from a prospectively maintained database at the two academic university hospitals. All patients were poorly suited for fenestrated or branched endograft repair (F/BEVAR) and deemed poor-risk for open surgery. RESULTS: Forty-nine multiple ChEVAR were performed in 44 men and 5 women, with complete outcome data at a mean follow-up of 18 months. Overall, 2 patients died during follow-up (4%) with no aneurysm-related mortality and two ruptures after ChEVAR (4.1%) due to a type Ib endoleak from iliac limb pullout and persistent gutter-flow, both repaired with endovascular means. No stroke or spinal cord ischemia was noted during the follow-up period. Reintervention was undertaken in eight patients (16.3%) with five reinterventions for persistent gutter-flow and four chimney graft-associated. Three-vessel ChEVAR was performed in 16 patients, with two-vessel ChEVAR in 33 patients for a total of 114 chimney branches (mean 2.3 chimneys per patient). There were 21 superior mesenteric artery (SMA), 45 right renal, 46 left renal artery (LRA), and two accessory LRA chimneys placed. Antegrade configuration of chimney branches was chosen in 43 patients (88%). There were no significant differences between three-vessel and two-vessel ChEVAR upon univariate analysis in aneurysm size (65.6 vs 60.5 mm; p = 0.059), iliac diameter (7.3 vs 7.1 mm; p = 0.85), or endograft oversizing (30 vs 32.5%; p = 0.43). Three-vessel ChEVAR was associated with a larger aneurysm neck diameter (28.4 vs 25.0 mm; p = 0.021), shorter native infrarenal neck (0.5 vs 3.37 mm; p = 0.002) as well as longer seal zone (36.33 vs 22.67 mm; p = 0.005) compared with two-vessel ChEVAR. At follow-up, there were no significant differences in gutter area between three-vessel and two-vessel ChEVAR (18.9 vs 15.7 mm3; p = 0.73) nor the rate of persistent gutter-flow (12.5 vs 9.1%; p = 0.71). CONCLUSION: Reintervention to multiple chimney grafts and for persistent gutter-flow is higher compared to single chimneys and demands close surveillance. However, based upon this combined transantlantic experience, we believe multiple ChEVAR provides a reasonable and safe option for complex aortic aneurysm repair when open or custom endografts are not available or indicated based on their Instructions For use, even when triple chimney grafts are required. The optimal configuration for multiple ChEVAR still warrants further study, although theoretical preliminary advantages may exist for a combination of antegrade and retrograde chimneys.
Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Feminino , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Desenho de Prótese , Resultado do Tratamento , Fatores de Risco , Estudos RetrospectivosRESUMO
OBJECTIVE: In the treatment of pararenal abdominal aortic aneurysms and aortic pathologic processes, chimney endovascular aneurysm repair (CHEVAR) represents an alternative technique for urgent cases. The aim of the study was to evaluate the outcomes of CHEVAR in the elective setting. METHODS: We performed a retrospective analysis of prospectively collected records of 165 consecutive asymptomatic CHEVAR patients who were treated between March 2009 and January 2018 with the Endurant stent graft (Medtronic, Santa Rosa, Calif). A total of 244 chimney grafts (CGs) were implanted. The primary end point was clinical success, defined as freedom from procedure-related mortality, persistent type IA endoleak, occlusion or high-grade stenosis (>70%) of CGs, and any chimney technique-related secondary procedure for the entire follow-up period. Secondary clinical success included patients with successful treatment of a primary end point with a secondary endovascular procedure. RESULTS: All 244 targeted chimney vessels were successfully cannulated. Total perioperative morbidity was 7.8% (n = 13), including 3 (1.8%) cases of bowel ischemia, 1 (0.6%) patient with renal ischemia, and 1 patient (0.6%) with stroke. Median follow-up was 25.5 ± 2.2 months. Both 30-day and follow-up procedure-related mortality rates were 1.8% (n = 3). Primary and secondary freedom from persistent type IA endoleak rates were 96.4% (n = 159) and 99.4% (n = 164), respectively. Primary and secondary CG patency rates were 92.2% (n = 225) and 95.9% (n = 234), respectively. The rate of reinterventions related to the chimney technique was 10.9% (n = 18), and 83.3% of them were performed by endovascular means. The estimated cumulative primary patency and freedom from persistent type IA endoleak were 87.5% and 95.3%, respectively, and the primary and secondary clinical successes rates at midterm were 80.3% and 87.5%, respectively. CONCLUSIONS: The elective use of CHEVAR with the Endurant stent graft in our series showed favorable midterm clinical results, which are similar to the published results of other total endovascular modalities. A prospective randomized trial of elective treatment of pararenal abdominal aortic aneurysms and aortic pathologic processes with current endovascular options is needed to assess the value of CHEVAR in the elective setting.
Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/patologia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Comorbidade , Procedimentos Cirúrgicos Eletivos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução VascularRESUMO
OBJECTIVE: The early and short-term efficacy of the snorkel/chimney technique for endovascular aortic aneurysm repair (ch-EVAR) have been previously reported. However, long-term ch-EVAR performance, vessel patency, and patient survival remain unknown. Our study evaluated the late outcomes to identify possible predictors of failure within the PERICLES (performance of the chimney technique for the treatment of complex aortic pathologies) registry. METHODS: Clinical and radiographic data from patients who had undergone ch-EVAR from 2008 to 2014 in the PERICLES registry were updated with an extension of the follow-up. Regression models were used to evaluate the relevant anatomic and operative characteristics as factors influencing the late results. We focused on patients with ≥30 months of follow-up (mean, 46.6 months; range, 30-120 months). RESULTS: A total of 517 patients from the initial PERICLES registry were included in the present analysis, from which the mean follow-up was updated from 17.1 months to 28.2 months (range, 1-120 months). All-cause mortality at the latest follow-up was 25.5% (n = 132), with an estimated patient survival of 87.6%, 74.4%, and 66.1% at 1, 3, and 5 years, respectively. A subgroup of 244 patients with 387 chimney grafts placed (335 renal arteries, 42 superior mesenteric arteries, 10 celiac arteries) and follow-up for ≥30 months was used to analyze specific anatomic and device predictors of adverse events. In the subgroup, the technical success was 88.9%, and the primary patency was 94%, 92.8%, 92%, and 90.5% at 2.5, 3, 4, and 5 years, respectively. The mean aneurysm sac regression was 7.8 ± 11.4 mm (P < .0001). Chimney graft occlusion had occurred in 24 target vessels (6.2%). Late open conversion was required in 5 patients for endograft infection in 2, persistent type Ia endoleak in 2, and endotension in 1 patient. The absence of an infrarenal neck (odds ratio, 2.86; 95% confidence interval, 1.32-6.19; P = .007) was significantly associated with long-term device-related complications. A sealing zone diameter >30 mm was significantly associated with persistent or late type Ia endoleak (odds ratio, 4.86; 95% confidence interval, 1.42-16.59; P = .012). CONCLUSIONS: The present analysis of the PERICLES registry has provided the missing long-term experience for the ch-EVAR technique, showing favorable results with more than one half of the patients surviving for >5 years and a chimney graft branch vessel patency of 92%. The absence of an infrarenal neck and treatment with a sealing zone diameter >30 mm were the main anatomic long-term limits of the technique, requiring adequate preoperative planning and determination of the appropriate indication.
Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Sistema de Registros , Reoperação , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do TratamentoRESUMO
Late open conversion in our center has been reviewed in the past 8 years, comparing 1997-2011 (first period group A) with 2012-2020 (second period group B). A retrospective analysis of patients treated at our centre by standard EVAR for infrarenal aortic aneurysm requiring late open conversion between January 1997 and February 2020 was performed. All stent grafts were implanted according to their current IFU all patients. The data concerning intra and postoperative complications were collected. Post-operative evaluated data include: ICU (Intensive Care Unit) stay, major peri-operative (<30 days) complications, in hospital mortality, length of hospital stay, 30-days mortality, and mid-term outcomes. Between January 2012 and February 2020 (group B), in our institution 8 patients previously treated by stent graft with endoleak underwent open surgery. The incidence of conversions and the 30-day mortality rate were compared with that of previous years, from January 1997 to December 2011 (group A). 481 patients submitted to EVAR in a second part of the analysis have been considered, 8 patients underwent late open conversion (1.7%) (Group B) due to endoleak. Among January 1997 and December 2011 overall 268 EVAR were performed; during this first study period, surgical conversion had been performed in 14 patients (5.2%) (Group A). The average time from EVAR to open conversion was four years (range 12-88 months) in Group B, and it was 30 months (range 1-82 months) in Group A. In most cases, in both group A and group B the proximal aortic cross-clamping were infrarenal. After the emergent procedure in Group B (12.5%), we have observed a death, whereas three patients died in Group A in urgent situations (21.4%). The more frequent indication for open surgery is the Endoleak type 1 and migration in the two considered periods. Adherence with current IFU and the technical progress in endoprosthesis design maintain lower rate incidence. In most cases, open surgery for prostheses that require explantation can be performed with infrarenal clamping. Partial removal of the endoprosthesis in selected cases makes open conversion easier and appears durable. The results are unfair by numerous comorbidities; in both periods, urgent graft removal seems to elevate both mortality and morbidity, compared to elective surgery.
Assuntos
Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Humanos , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do TratamentoRESUMO
PURPOSE: To evaluate the long-term results associated with the Zenith Alpha thoracic stent-graft, which was designed to address challenging access vessel anatomy. MATERIALS AND METHODS: A retrospective analysis was conducted of 44 consecutive patients (mean age 72.5±8.3 years; 25 men) treated in a single center between August 2010 and October 2014 with a minimum follow-up of 5 years in survivors. The Zenith Alpha thoracic stent-graft was used to treat thoracic aortic aneurysms (n=37), thoracoabdominal aortic aneurysm (n=5), or penetrating aortic ulcer (n=2). Ten patients (23%) were American Society of Anesthesiologists class IV, and 9 (20%) had nonelective procedures. Access vessel anatomy was demanding (mean minimum diameter 5.4 mm, tortuosity index 1.3). The primary endpoint at 5 years was ongoing clinical success (freedom from aneurysm-/procedure-related death, secondary intervention, type I or III endoleak, infection, thrombosis, aneurysm expansion, rupture, or conversion). Secondary endpoints were freedom from all-cause mortality, device migration, stent fractures, fabric erosions, endoleaks, neurological events, and access vessel complications. RESULTS: The ongoing clinical success was 84% (37 of 44 patients) owing to 4 aneurysm-related deaths (9%), 3 type I or III endoleaks (1 in a deceased patient), and 1 aneurysm expansion without detectable endoleak. There were 3 access vessel complications (7%), and no postoperative neurological events. Migration was observed in 2 cases (5%). There were no stent fractures or fabric tears. CONCLUSION: Despite the alterations in stent-graft design and material to reduce profile, the Zenith Alpha thoracic stent-graft showed favorable long-term results even in multimorbid patients with demanding iliac anatomy.
Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Resultado do TratamentoRESUMO
OBJECTIVE: To evaluate early and follow-up outcomes following bilateral use of iliac branch devices (IBD) for aortoiliac endografting and assess the impact of center volume. We used data from the pELVIS international multicentric registry. METHODS: For the purpose of this study, only those patients receiving concomitant bilateral IBD implantation were analyzed. To assess the impact that procedural volume of bilateral IBD implantation could have on early and follow-up outcomes, participating institutions were classified as Site(s) A if they had performed >10 and/or >20% concomitant bilateral IBD procedure, otherwise they were classified as Site(s) B. Endpoints of the analysis included early (ie, 30-day) mortality and morbidity, as well as all-cause and aneurysm-related mortality during follow-up. Additional endpoints that were evaluated included IBD-related reinterventions, IBD occlusion or stenosis requiring reintervention (ie, loss of primary patency), and IBD-related type I endoleak. RESULTS: Overall, 96 patients received bilateral IBD implantation (out of 910 procedures collected in the whole pELVIS cohort), of whom 65 were treated at Site A (ie, Group A) and 31 were treated at Site(s) B (ie, Group B). In total, only 1 death occurred within 30 days from bilateral IBD implantation, and 9 patients experienced at least 1 major complication without any significant difference between subjects in Group A versus those in Group B (10.8% vs 6.5%, p=0.714). In the overall cohort, the 2-year freedom from IBD-related type I endoleaks and IBD primary patency were 96% and 92%, respectively; no significant differences were seen in those rates between Group A or Group B (95% vs 100%, p=0.335; 93% vs 88%, p=0.470). Freedom from any IBD-related reinterventions was 83% at 2 years, with similar rates between study groups (85% vs 83%, p=0.904). CONCLUSIONS: Within the pELVIS registry, concomitant bilateral IBD implantation is a safe and feasible technique for management of aortoiliac aneurysms in patients with suitable anatomy. Despite increased technical complexity, effectiveness of the repair is satisfactory with low rates of IBD-related adverse events at mid-term follow-up. Procedural volume does not seem to affect technical or clinical outcomes after bilateral use of IBD, which remains a favorable treatment option in selected patients.
RESUMO
OBJECTIVE: The aim was to identify predictors of adequate pre-operative sizing and planning for chimney endovascular aortic repair (ChEVAR) in order to reduce the incidence of persistent type Ia endoleaks (IaELs) without influencing chimney graft (CG) patency. METHODS: Consecutive patients who underwent ChEVAR between January 2009 and December 2017 at a single centre were evaluated retrospectively. Included were patients treated with one device combination (Medtronic Endurant mated with Getinge Advanta V12/iCast) and placement of single or double CG. The freedom from IaEL related re-interventions and primary CG patency was estimated by measuring aortic stent graft oversizing (OS), total neck length (TNL), and a composite parameter (L-OS: TNL [mm] + OS [%]). RESULTS: Seventy-three patients who underwent placement of 101 CGs (45 single, 28 double) met the inclusion criteria. The median radiological follow up was 25.5 (interquartile range [IQR] 12-48) months. Freedom from IaEL related re-intervention was achieved in 94.6% with a median OS of 38.5% (IQR 30%-44%, p = .004), TNL 19 mm (16-25 mm, p = .62), and L-OS 59 (51-65, p = .018). Primary CG patency was achieved in 95% of the cases with a median OS of 36% (29%-42%, p = .008), TNL 19 mm (15.5-26 mm, p = .91), and L-OS 57 (50-64, p = .005). By using the receiver operating characteristic curve, an optimal cut off to prevent IaEL related re-interventions was identified by an OS of 30% (p < .001; L-OS 55, p = .006) and to avoid CG stenosis/occlusions by OS 42% (p < .001; L-OS 65, p < .001). In multivariable analysis, aortic endograft OS was the only independent parameter preventive for IaEL related re-intervention (odds ratio, 0.78; 95% confidence interval, 0.61-0.99). CONCLUSION: With the Endurant-Advanta V12/iCast combination, an aortic stent graft OS of at least 30% (range 30%-42%) should be used to avoid type Ia endoleaks and likewise to ensure CG patency.
Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Aortografia , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Bases de Dados Factuais , Endoleak/etiologia , Endoleak/prevenção & controle , Procedimentos Endovasculares/efeitos adversos , Feminino , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/prevenção & controle , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução VascularRESUMO
BACKGROUND: The post-implantation syndrome may occur shortly after endovascular aneurysm repair in patients treated for abdominal aortic aneurysm. Different types of biomaterials may provoke varying inflammatory responses in patients receiving different endografts. The purpose of this article is to evaluate the PIS after EVAR and the influence of different types of device fabric. METHODS: All patients submitted to elective AAA endovascular repair at our institution from January 2014 to December 2019 were enrolled. The PIS was defined by a body temperature of >38°C and WBC >12'000/µl without any evidence of an infection during (48h) the observation period. RESULTS: Three hundred and sixty-seven patients (89% males) were enrolled in this study and post-implantation syndrome occurred in 41 cases (11.2%). The incidence of PIS was significantly higher (P< 0.001) in patients treated with polyester stent grafts (39/201, 19,4%) compared to patients with PTFE stent grafts (2/166, 1,2%). CRP was related to the presence of PIS with a cut-off values of 109.31 mg/dL (Pâ¯=â¯0.0052). The median in-hospital stay considering the polyester group was 6,2 days, while in the PTFE group it was 5,6 days (Pâ¯=â¯0.04). CONCLUSIONS: The postoperative inflammatory response after EVAR seems significantly higher by using polyester stent graft compared to PTFE devices. CRP could be a useful biomarker in defining PIS. Multi-center studies are necessary to confirm these data.
Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Poliésteres , Stents , Síndrome de Resposta Inflamatória Sistêmica/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Bases de Dados Factuais , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Politetrafluoretileno , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Síndrome de Resposta Inflamatória Sistêmica/diagnóstico , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: Durability of low-profile branched aortic stent-grafts (LPSG) in the treatment of patients with thoracoabdominal aortic aneurysms (TAAA) remains unclear. Objective of this study is to compare the outcomes of LPSG with standard profile branched aortic stent-grafts (SPSG). METHODS: Between January 2016 and January 2020, 225 consecutive patients with TAAA were treated by branched endovascular aortic repair (BEVAR). Twenty-four patients who were treated with a LPSG were compared to 24 patients who received SPSG as a control group. Control patients were selected according to aneurysm size (maximum aneurysm diameter) and extension (Crawford classification) as well as availability of adequate preoperative and postoperative CT-angiograms at 24 months. The primary endpoint was ongoing clinical success defined as successful implantation and freedom from aneurysm- or procedure-related death, secondary intervention, type I or III endoleak, infection, thrombosis, aneurysm expansion or rupture and conversion. Secondary endpoints were radiological changes of the branched endograft (migration, shortening, scoliosis, lordosis, and fracture). RESULTS: After a median follow-up of 22.6 (LPSG) and 26.2 months (SPSG), no significant difference was found in terms of technical success (100% in both groups), late mortality (4.2% vs 0%), aneurysm diameter increase (4.2% in both groups) and reinterventions (25% vs 37.5%). Infection, thrombosis, aneurysm expansion or rupture and conversion were not observed. Radiological analysis of aortic graft remodeling showed no fracture and no significant migration, shortening, scoliosis and lordosis of the LPSG (6.1 mm, 7.5 mm, 12.8° and 6.1°) compared to SPSG (3.9 mm, 5.1 mm, 7.9° and 5.6°) after 2 years. CONCLUSION: The clinical and radiological findings of the present study showed no increased mortality and complications for the matched patients who underwent treatment with low-profile vs standard-profile BEVAR. This study provides preliminary evidence of safety and efficacy of low-profile branched endografts in patients with demanding iliac access vessels.
Assuntos
Aneurisma da Aorta Torácica/cirurgia , Aortografia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Valor Preditivo dos Testes , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
OBJECTIVES: The results of branched endovascular repair of thoracoabdominal aneurysms are mainly dependent on durability of the graft used. The purpose of this study was to evaluate postoperative aortic main body and bridging stent-graft remodeling, and their impact on bridging stent-graft instability at one year. METHODS: Computed tomoangiographies of 43 patients (43 aortic main body mated with 171 bridging stent-grafts) were analyzed before and after branched endovascular repair as well as after a follow-up of 12 months. Primary endpoint was aortic main body remodeling (migration >5 mm, shortening >5 mm, scoliosis >5° or lordosis >5°). Shortening was defined as a reduced length in the long axis, scoliosis as left-right curvature, and lordosis as antero-posterior curvature. Aortic main body remodeling, aneurysm sac changes, and bridging stent-graft tortuosity were evaluated to study their correlations and the impact on the bridging stent-graft instability. RESULTS: At 12 months, aortic main body remodeling was observed in 72% of the cases, migration in 39.5% (mean 5.21 mm), shortening in 41.9% (mean 5.79 mm), scoliosis in 58.1%, (mean 10.10°), lordosis in 44.2% (mean 5.78°). Migration, shortening, and scoliosis were more frequent in patients with larger aneurysms (p = .005), while scoliosis was significantly more frequent in type II thoracoabdominal aneurysm (p = .019). Aortic main body remodeling was significantly associated to bridging stent-graft remodeling (r: 0.3-0.48). The bridging stent-graft instability rate was 9.3%. Despite a trend toward significance (p = .07), none of the evaluated aortic main body and bridging stent-graft changes were associated with bridging stent-graft instability at 12 months. CONCLUSIONS: Aortic main body remodeling is frequent especially in large and extended thoracoabdominal aneurysm aneurysms. Aortic main body and bridging stent-graft remodeling was significantly correlated. While these geometric changes had no significant impact on bridging stent-graft instability at one year, a close long-term follow-up after branched endovascular repair could predict bridging stent-graft failures.
Assuntos
Aorta/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Remodelação Vascular , Idoso , Aorta/diagnóstico por imagem , Aorta/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Bases de Dados Factuais , Procedimentos Endovasculares/efeitos adversos , Feminino , Migração de Corpo Estranho/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do TratamentoRESUMO
PURPOSE: To analyze the overall performance of flexible nitinol stents used to line chimney grafts (CGs) during chimney endovascular aneurysm repair (chEVAR) of pararenal pathologies. MATERIALS AND METHODS: A retrospective review was conducted of all 116 elective patients (mean age 74.3±7.2 years; 103 men) who underwent chEVAR with balloon-expandable Advanta V12/iCAST CGs in combination with the Endurant stent-graft between January 2009 and December 2017 at a single center. CG lining with a nitinol stent was electively performed in 43 target vessels of 32 patients. The Kaplan-Meier method was used to estimate the primary outcomes of CG patency and freedom from reintervention (FFR) at the patient level and according to the use of a stent to line the CG. Estimates are reported with the 95% confidence interval (CI). Adjusted odds ratios (ORs) were calculated to identify any confounding effect between the presence/absence of a stent lining or according to the number of CGs. RESULTS: The mean radiological follow-up was 27.3 months (range 22.1-32.6). During this time, 8 CGs (4.7%) became occluded, 6 of them were lined with stents. Restoration of patency was possible in 3 of the 4 occluded stents that were associated with symptoms. First-year primary patency estimates were 96.9% (95% CI 92.5% to 100%) for the unlined group vs 77.1% (95% CI 58% to 95.3%; p=0.001) for the lined group, while FFR was 87.6% (95% CI 79.9% to 95.2%) vs 83.4% (95% CI 68.1% to 98.6%; p=0.82), respectively. Lining represented an independent risk factor for CG occlusion (OR 9.9, p=0.006). CONCLUSION: CG lining performed mainly in angulated renal arteries during chEVAR was significantly associated with CG occlusion. These findings highlight the importance of not having the distal part of the CG impinge on the angulated segment of the target vessel.
Assuntos
Aneurisma , Implante de Prótese Vascular , Procedimentos Endovasculares , Artéria Renal , Stents , Idoso , Idoso de 80 Anos ou mais , Ligas , Aneurisma/diagnóstico por imagem , Aneurisma/cirurgia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Desenho de Prótese , Artéria Renal/diagnóstico por imagem , Artéria Renal/cirurgia , Estudos Retrospectivos , Fatores de Risco , Aço Inoxidável , Resultado do TratamentoRESUMO
BACKGROUND: The aim of this study is to assess our experience and mid-term outcomes using Jetstream atherectomy system for treatment of femoropopliteal artery disease (FPAD). METHODS: Data of 30 patients with FPAD treated at our center between 2013 and 2016 were analyzed. Two subgroups of patients were identified: Group A included patients (n = 18) with de novo lesions; Group B (n = 12) included those with in-stent restenosis. The primary study end points assessed were technical success, perioperative mortality, and major adverse event (MAE) rate at 30 days (distal embolization, major amputation, and target lesion revascularization). Other outcomes measured were survival, primary, and secondary patency, and freedom from amputation at 1 and 3 years of follow-up, respectively. RESULTS: Technical success was 100% for both groups. The MAE rate was 8.7%. No distal filter was adopted during intervention. Angioplasty was associated with 93.3% of cases (93.3% vs. 100%; P = 0.15), drug-eluting balloon (DEB) in 12 cases (22.2% vs. 66.6%; P = 0.008), drug-eluting stent and bare metal implantation in 1 (5.6% vs. 0%; P = 1) and 4 cases (11.1% vs. 16.7%; P = 1), respectively. The cumulative primary and secondary patency rates were 75.1% and 95.5% at 1 year, and 70.4% and 84.8% at 3 years of follow-up, respectively. The survival and freedom from amputation were 96.4% and 85.8% at 1 and 3 years of follow-up, respectively. The freedom from target lesion revascularization was 91.7% and 83.4% at 1 and 3 years from intervention. CONCLUSIONS: The use of the Jetstream appears to be safe and feasible with no distal embolization and low rate perioperative complications. Moreover, encouraging outcomes were observed when atherectomy was associated to DEB angioplasty.
Assuntos
Angioplastia com Balão , Aterectomia/instrumentação , Artéria Femoral , Doença Arterial Periférica/terapia , Idoso , Idoso de 80 Anos ou mais , Amputação Cirúrgica , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/instrumentação , Angioplastia com Balão/mortalidade , Aterectomia/efeitos adversos , Aterectomia/mortalidade , Materiais Revestidos Biocompatíveis , Bases de Dados Factuais , Stents Farmacológicos , Desenho de Equipamento , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Itália , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/mortalidade , Doença Arterial Periférica/fisiopatologia , Intervalo Livre de Progressão , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Dispositivos de Acesso Vascular , Grau de Desobstrução VascularRESUMO
PURPOSE: The aim of this retrospective analysis was to evaluate the performance of the chimney (ch) technique in the treatment of type Ia endoleaks after standard endovascular aneurysm repair (EVAR). METHODS: Between January 2008 and December 2014, 517 chEVAR procedures were performed in 13 US and European vascular centers (PERICLES registry). Thirty-nine patients (mean age 76.9±7.1 years; 33 men) were treated for persistent type Ia endoleak and had computed tomography angiography or magnetic resonance angiography follow-up at >1 month. Endurant abdominal stent-grafts were used in the 20 cases. Single chimney graft placement was performed in 18 (46%) patients and multiple in 21 (54%). Overall, 70 visceral vessels were targeted for revascularization. RESULTS: Technical success was achieved in 35 (89.7%) cases; 3 persistent type Ia endoleaks and 1 chimney graft occlusion were detected within the first 30 days. Thirty-day mortality was 2.6%. Two other deaths (not aneurysm related) occurred during a mean follow-up of 21.9 months (0.23-71.3). Primary patency of the chimney grafts was 94.3% at 36 months. In a subgroup analysis comparing Endurant to other stent-grafts, no significant differences were observed regarding persistent endoleak [1/20 (5%) vs 2/19 (11%), p=0.6] or reintervention [1/20 (5%) vs 0/19 (0%)]. CONCLUSION: The present series demonstrates that chEVAR in the treatment of post-EVAR type Ia endoleaks has satisfactory results independent of the abdominal and chimney graft combinations. Midterm results show that chEVAR is an effective method for treating type Ia endoleaks.
Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Endoleak/cirurgia , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Europa (Continente) , Feminino , Humanos , Masculino , Desenho de Prótese , Sistema de Registros , Reoperação , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados UnidosRESUMO
BACKGROUND: Large gutters after chimney procedures are one of the main causes of type I endoleak (EL-I). This study aims to evaluate a new tailored planning named "Over-SIRIX," based on Osirix Imaging Software, to choose the correct main graft oversizing in order to minimize EL-I incidence. METHODS: From 2008 to 2015, 34 patients were treated with parallel grafts for aortic arch diseases at our institution. The study included 22 patients with single stent and antegrade flow configuration; they were divided into 2 groups (PRE- and POST-"Over-SIRIX"). "Over-SIRIX" was carried out in the retrospective group (PRE-"Over-SIRIX"), and it was used to plan the endovascular procedure in the prospective group (POST-"Over-SIRIX"). Through the multiplanar reconstruction (MPR) of the preoperative computed tomography angiography (CTA), the proximal neck of the chimney grafts was studied. Stent and endograft configurations were drawn in order to minimize the "gutters." To obtain the ideal main graft sizing (I-Size), a formula was used by adding the custom sizing (C-Size) to the disease oversizing (D-Over). The same MPR imaging was evaluated on postoperative CTA to study gutters area and presence of EL-I. RESULTS: The mean I-Size was 41.67 mm that was equivalent to an ideal oversizing of 19.3% (range 10-28%). The gutters area decreased from 7.3 to 1.7 mm2 (PRE/POST) and EL-I rate from 28.5% to 0% (PRE/POST). Gutters area bigger than 7.5 mm2 and planning made without "Over-SIRIX" were significantly associated (P < 0.05) to EL-I. CONCLUSIONS: "Over-SIRIX" appears to be a feasible method to customize planning during chimney technique, reducing the risk of EL-I which is significantly related to the presence and size of the gutters.
Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Desenho de Prótese , Stents , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/mortalidade , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Angiografia por Tomografia Computadorizada , Endoleak/etiologia , Endoleak/prevenção & controle , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Estudos de Viabilidade , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Cidade de Roma , Resultado do TratamentoRESUMO
INTRODUCTION: Staged endovascular treatment of thoracoabdominal aortic aneurysms (TAAA) has been proved to be an effective strategy to reduce the risk of spinal cord ischemia (SCI). Several techniques have been described: some imply the staged coverage of the aorta, other the temporarily perfusion of the sac through a branch left unstented or a dedicated branch that will be occluded later. The aim of those is to facilitate the expansion of the collateral network that perfuses the spinal cord. However, each of them, have some disadvantages such as the need of two interventions of big magnitude and the risk of target vessel occlusion or endograft displacement. We describe a new technique to treat TAAA in a staged manner. TECHNIQUE: The first step of our technique is the thoracoabdominal endograft deployment with the branching of all target vessels; one of these is branched with a bare stent inside which a covered stent will be placed in a second step, which can be perfomed under local anesthesia. We named this technique "open branch" (OB). Before insertion of the covered stent, a balloon is inflated inside the bare stent to simulate the complete sac exclusion to evaluate eventual neurological complication. RESULTS: Two patients with Crawford type II TAAA and one with a suprarenal aneurysm following the open repair of an infrarenal aortic aneurysm were treated. No cases of SCI were observed after the two procedures. Median interval time between the two procedures was 8, 6 weeks (4-16). Between the two steps, no aneurysm growth or rupture and no branch occlusion or endograft displacement was observed. CONCLUSIONS: These three cases of "OB" technique show that this is a safe and feasible alternative strategy to treat TAAA in a staged manner.
Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Paraplegia/prevenção & controle , Isquemia do Cordão Espinal/prevenção & controle , Idoso , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Masculino , Paraplegia/diagnóstico , Paraplegia/etiologia , Desenho de Prótese , Fatores de Risco , Isquemia do Cordão Espinal/diagnóstico , Isquemia do Cordão Espinal/etiologia , Stents , Resultado do TratamentoRESUMO
PURPOSE: To evaluate the outcomes of carotid artery stenting (CAS) with Wallstents in a single-center experience. METHODS: From January 2003 to December 2013, 1000 carotid artery lesions were treated with Carotid Wallstents under cerebral protection in 877 patients (mean age 71.7 ± 8 years; 621 men). Indications for treatment were de novo lesions (>70% asymptomatic and >60% symptomatic); stenoses following carotid endarterectomy, radiation, or neck surgery; contralateral laryngeal nerve palsy; and high surgical risk. All the patients underwent duplex ultrasound and clinical evaluation during follow-up; radiography was performed when fracture or stent migration was suggested by ultrasound. RESULTS: Procedure success was achieved in 99.3% of patients. Major and minor 30-day adverse events occurred in 2.1% of patients, including stroke (1.8%: 1.3% minor, 0.5% major), myocardial infarction (0.1%), and death (0.2%). Plaque morphology, nature of stenosis, and symptomatic status were significantly associated with the risk of postoperative neurologic events. Restenosis occurred in 3.2% at a mean 45.5-month follow-up and was significantly associated with diabetes, smoking, symptomatic stenosis, de novo stenosis, and calcification (plaque III/IV). No fracture or migration was registered during follow-up. CONCLUSION: CAS is a valid method for treating carotid artery disease, with very low rates of major adverse events and neurologic complications. The Carotid Wallstent seems to have excellent results, even with complex plaque morphology, and a low incidence of restenosis at follow-up.
Assuntos
Angioplastia/instrumentação , Estenose das Carótidas/terapia , Vasos Coronários , Stents , Idoso , Idoso de 80 Anos ou mais , Angioplastia/efeitos adversos , Angioplastia/mortalidade , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/mortalidade , Angiografia por Tomografia Computadorizada , Vasos Coronários/diagnóstico por imagem , Intervalo Livre de Doença , Feminino , Humanos , Estimativa de Kaplan-Meier , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica , Desenho de Prótese , Recidiva , Fatores de Risco , Cidade de Roma , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler DuplaRESUMO
OBJECTIVE: The goal of this study was to present open surgical conversion with graft salvage or "semiconversion" as a definitive and safe treatment for untreatable and persistent type II endoleaks causing sac enlargement after endovascular aneurysm repair. METHODS: Between January 2001 and December 2014, 25 of 1623 endovascular aortic repair (EVAR) patients were selected as candidates for open semiconversion. The indication was persistent type II endoleak in 13 patients (12 of whom received previous attempts of embolization), type I and II endoleak in 2 patients, and sac growth without imaging evidence of endoleak in the other 10. After the infrarenal aorta was prepared (via a retroperitoneal access, whenever possible), the technique consisted of performing a banding of the neck with Teflon (DuPont, Wilmington, Del), a sacotomy to remove the thrombus or the hygroma, or both, and then suturing all of the feeding vessels that were found. Proximal and distal fenestrations were performed to avoid sac repressurization. RESULTS: The semiconversion was performed after a mean of 74 months after the initial EVAR. The mean aneurysm size at the time of the EVAR was 6.0 cm (range, 5.0-9.5 cm), and the mean aneurysm size at the time of the semiconversion was 7.7 cm (range, 5.5-11.5 cm). The overall aneurysm size increase was 38%, and the average growth rate was 8.2% per year. One patient had a stable aneurysm size but was treated because of an emergency condition. Technical success was 100%, with resolution of the endoleak and no perioperative deaths. Four cardiac deaths were registered at 12, 26, 30, and 60 months (mean follow-up, 42 months; range, 1-80 months). CONCLUSIONS: Graft salvage appears to be a valid option compared with open repair when considering treatment of persistent type II endoleak. This case series shows that semiconversion is a safe and effective treatment for otherwise untreatable type II endoleak.