Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Oral Investig ; 17(4): 1227-34, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-22893034

RESUMO

OBJECTIVES: Cavitation arising within the water around the oscillating ultrasonic scaler tip is an area that may lead to advances in enhancing biofilm removal. The aim of this study is to map the occurrence of cavitation around scaler tips under loaded conditions. MATERIALS AND METHODS: Two designs of piezoelectric ultrasonic scaling probes were evaluated with a scanning laser vibrometer and luminol dosimetric system under loaded (100 g/200 g) and unloaded conditions. Loads were applied to the probe tips via teeth mounted in a load-measuring apparatus. RESULTS: There was a positive correlation between probe displacement amplitude and cavitation production for ultrasonic probes. The position of cavitation at the tip of each probe was greater under loaded conditions than unloaded and for the longer P probe towards the tip. CONCLUSIONS: Whilst increasing vibration displacement amplitude of ultrasonic scalers increases the occurrence of cavitation, factors such as the length of the probe influence the amount of cavitation activity generated. The application of load affects the production of cavitation at the most clinically relevant area-the tip. CLINICAL RELEVANCE: Loading and the design of ultrasonic scalers lead to maximising the occurrence of the cavitation at the tip and enhance the cleaning efficiency of the scaler.


Assuntos
Raspagem Dentária/instrumentação , Análise do Estresse Dentário , Terapia por Ultrassom/instrumentação , Desenho de Equipamento , Humanos , Modelos Lineares , Dente Molar , Oscilometria , Estatísticas não Paramétricas , Vibração
2.
J Clin Periodontol ; 36(1): 44-50, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19017036

RESUMO

BACKGROUND: It is stated that the oscillation patterns of dental ultrasonic scalers are dependent upon whether the instrument is of a magnetostrictive or piezoelectric design. These patterns are then linked to differences in root surface debridement in vitro. MATERIAL AND METHODS: Piezoelectric (A, P) and magnetostrictive (Slimline, TFI-3) ultrasonic scalers (three of each) were evaluated, loaded (100 g/200 g) and unloaded with a 3D laser vibrometer. Loads were applied to the probe tips via teeth mounted in a load-measuring device. RESULTS: Elliptical motion was demonstrated for all probes under loaded and unloaded conditions. Loading flattened the elliptical motion along the length of the probe. Unloaded, Slimline tip 1 was significantly different to tips 2 and 3 (p<0.0001). There were no differences between the A-tips (p>0.207). All TFI-3 tips were different to each other (p<0.0001). P-tips 1 and 2 were different to each other (p=0.046). Loaded, Slimline tips were different to each other (p<0.001). There were no differences between the P probes (p>0.867). Generator power increased all Slimline and P tip vibrations (p<0.0001). CONCLUSIONS: Probe oscillation patterns are independent of ultrasound production mechanism and are dependent upon probe shape and generator power. Loaded probes oscillated with an elliptical pattern.


Assuntos
Raspagem Dentária/instrumentação , Oscilometria/instrumentação , Terapia por Ultrassom/instrumentação , Vibração , Instrumentos Odontológicos , Holografia/instrumentação , Imageamento Tridimensional , Vibração/uso terapêutico
3.
Ultrason Sonochem ; 16(5): 692-7, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19119051

RESUMO

Ultrasonic scalers are used in dentistry to remove calculus and other contaminants from teeth. One mechanism which may assist in the cleaning is cavitation generated in cooling water around the scaler. The vibratory motion of three designs of scaler tip in a water bath has been characterised by laser vibrometry, and compared with the spatial distribution of cavitation around the scaler tips observed using sonochemiluminescence from a luminol solution. The type of cavitation was confirmed by acoustic emission analysed by a 'Cavimeter' supplied by NPL. A node/antinode vibration pattern was observed, with the maximum displacement of each type of tip occurring at the free end. High levels of cavitation activity occurred in areas surrounding the vibration antinodes, although minimal levels were observed at the free end of the tip. There was also good correlation between vibration amplitude and sonochemiluminescence at other points along the scaler tip. 'Cavimeter' analysis correlated well with luminol observations, suggesting the presence of primarily transient cavitation.


Assuntos
Raspagem Dentária/instrumentação , Raspagem Dentária/métodos , Ultrassom , Vibração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA