Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 87
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sci Total Environ ; 912: 169454, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38123101

RESUMO

Using reclaimed water for agricultural irrigation is increasing worldwide to compensate for water scarcity. The aim of this work was to evaluate the uptake of some of the most commonly detected organic contaminants of emerging concern (CECs) and pesticides in regenerated water in a field study. Furthermore, it was studied their distribution and accumulation in the different parts of a crop (soil, plant and fruit). Three crops (cucumber, pepper and melon) were grown under controlled agronomic conditions in a greenhouse. In order to make an accurate evaluation of the process, "regenerated blank water" was spiked with 70 chemicals (including antibiotics, anti-inflammatories, analgesics, anaesthetics, anxiolytics, anticonvulsants, pesticides) at environmental concentrations (∼1 µg/L) and used for continuous crop irrigation. After crop season, the average total concentration of contaminants detected in the soil samples ranged from 132 to 232 µg/kg d.w depending of the crops type. Between 7 and 10 different contaminants were found in the harvested fruits, up to levels of 27.8 µg/kg f.w. cucumber, 12.4 µg/kg f.w. melon and 7.8 µg/kg f.w pepper. In general, cucumber fruit showed higher accumulation levels of contaminants than pepper and melon for most target analytes. The accumulation rates followed the order: root (0.2 %) < stem/leaf (1-4 %) < fruit (1-6 %) < soil (17-30 %). The experimental data obtained in this study were also used to assess the risk associated with the reuse of reclaimed water for crop irrigation as well to identify those contaminants that, due to their physicochemical properties, show higher accumulation rates and environmental impact.


Assuntos
Cucumis sativus , Praguicidas , Água , Produtos Agrícolas , Agricultura , Irrigação Agrícola , Solo
2.
Rapid Commun Mass Spectrom ; 27(11): 1237-50, 2013 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-23650037

RESUMO

RATIONALE: Polycyclic musks have become a concern due to their bioaccumulation potential and ecotoxicological effects. The HHCB transformation product (TP) (1,3,4,6,7,8-hexahydro-4,6,6,7,8,8-hexamethyl-cyclopenta[γ]-2-benzopyran; HHCB-lactone) is the most stable intermediate generated and it is frequently detected in river waters. The aim of this work was the identification of relevant TPs generated from UV irradiation and ozone treatments. METHODS: Identification of HHCB TPs was carried out by liquid chromatography/hybrid quadrupole time-of-flight mass spectrometry (LC/ESI-QTOF-MS) and two-dimensional gas chromatography/electron impact time-of-flight mass spectrometry (GC×GC-EI-TOF-MS). With LC/ESI-QTOF-MS, TPs were characterized by means of mass accuracy in both full-scan and MS/MS modes through information-dependent acquisition (IDA) and direct injection on-column. With stir bar sorptive extraction (SBSE)-GC×GC-EI-TOF-MS, identification was based on the enhanced separation capacity and screening of unknowns through the acquisition of full-range mass spectra. RESULTS: The effectiveness of these complementary techniques allowed a detailed evaluation of the main TPs. Eighteen TPs were elucidated based on mass accuracy, in both full-scan and MS/MS modes using LC/ESI-QTOF-MS with mass errors below 5 ppm and 10 ppm (mostly), respectively. Most of the TPs had not been analytically identified in previous studies. Separation of the enantiomeric species (R) and (S) of HHCB-lactone, and the identification of other relevant TPs, was performed using SBSE-GC×GC-EI-TOF-MS. CONCLUSIONS: LC/ESI-QTOF-MS and GC×GC-EI-TOF-MS analysis provides the best alternative for TP identification of chemicals of concern, which have a wide range of polarities and isobaric compounds. A prediction of PBT (persistence, bioaccumulation and toxicity) using the PBT Profiler program suggested a classification of 'very persistent' and 'very toxic' for most of the TPs identified.


Assuntos
Benzopiranos/química , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Cinética , Oxirredução , Ozônio/química , Raios Ultravioleta , Poluentes Químicos da Água/química
3.
Anal Bioanal Chem ; 405(18): 5901-14, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23322350

RESUMO

This work introduces a liquid chromatography-electrospray ionization-hybrid quadrupole/time-of-flight mass spectrometry (LC-ESI-QTOF-MS)-based method for qualitative and quantitative analysis of poly(amidoamine) (PAMAM) dendrimers of generations 0 to 3 in an aqueous matrix. The multiple charging of PAMAM dendrimers generated by means of ESI has provided key advantages in dendrimer identification by assignation of charge state through high resolution of isotopic clusters. Isotopic distribution in function of abundance of isotopes (12)C and (13)C yielded valuable and complementarity data for confident characterization. A mass accuracy below 3.8 ppm for the most abundant isotopes (diagnostic ions) provided unambiguous identification of PAMAM dendrimers. Validation of the LC-ESI-QTOF-MS method and matrix effect evaluation enabled reliable and reproducible quantification. The validation parameters, limits of quantification in the range of 0.012 to 1.73 µM, depending on the generation, good linear range (R > 0.996), repeatability (RSD < 13.4%), and reproducibility (RSD < 10.9%) demonstrated the suitability of the method for the quantification of dendrimers in aqueous matrices (water and wastewater). The added selectivity, achieved by multicharge phenomena, represents a clear advantage in screening aqueous mixtures due to the fact that the matrix had no significant effect on ionization, with what is evidenced by an absence of sensitivity loss in most generations of PAMAM dendrimers. Fig Liquid chromatography-electrospray ionization-hybrid quadrupole/time of flight mass spectrometry (LC-ESI-QTOF-MS) based method for qualitative and quantitative analysis of PAMAM dendrimers in aqueous matrix.


Assuntos
Dendrímeros/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Isótopos de Carbono/análise , Cromatografia Líquida/métodos , Reprodutibilidade dos Testes , Águas Residuárias/análise , Água/análise
4.
Sci Total Environ ; 859(Pt 2): 160462, 2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36435246

RESUMO

The use of reclaimed water for crop irrigation has been proposed as a suitable alternative for farmers in the coastal areas of Mediterranean countries, which suffer from greater water scarcity. In this work we study the impact on the water-soil-plant continuum of using reclaimed water for commercial crops irrigated over a long period, as well as the human risks associated with consuming the vegetables produced. Forty-four CECs were identified in the reclaimed water used for crop irrigation. Of these, twenty-four CECs were identified in the irrigated soil samples analysed. Tramadol, ofloxacin, tonalide, gemfibrozil, atenolol, caffeine, and cetirizine were the pharmaceuticals detected at the highest levels in the water samples (between 11 and 44 µg/L). The CECs with the highest average soil concentrations were tramadol (14.6 µg/kg), followed by cetirizine (13.2 µg/kg) and clarithromycin (12.7 µg/kg). In the irrigated vegetable samples analysed over the study period, carbamazepine, lidocaine, and caffeine were only detected at levels from 0.1 to 1.7 µg/kg. The CEC accumulation rate detected in the edible parts of the vegetables permanently irrigated with reclaimed water was very low (~1 %), whereas it was 33 % in the soils. The results revealed that consuming fruits harvested from plants irrigated for a long period with reclaimed water does not represent a risk to human health, opening the door to a circular economy of water. Nevertheless, for crop irrigation, future studies need to be conducted over longer periods and in other matrices to provide more scientific data on the safety of using reclaimed water.


Assuntos
Irrigação Agrícola , Poluentes do Solo , Humanos , Água/análise , Águas Residuárias , Produtos Agrícolas , Solo , Verduras , Poluentes do Solo/análise
5.
Chemosphere ; 333: 138959, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37209851

RESUMO

The sorption and vector effect of microplastics on the transfer of pesticides and polycyclic aromatic hydrocarbons (PAHs), as well as its impact on agriculture remain largely unexplored. This comparative study is first to investigate the sorption behavior of different pesticides and PAHs at environmentally realistic concentrations by model microplastics and microplastics derived from polyethylene mulch films. Sorption was found to be up to 90% higher in the case of microplastics derived from mulch films as opposed to pure polyethylene microspheres. For microplastics from mulch films, the sorption percentages for pesticides in media containing CaCl2 were reported to be: pyridate (75.68% and 52.44%), fenazaquin (48.54% and 32.02%), pyridaben (45.04% and 56.70%), bifenthrin (74.27% and 25.88%), etofenprox (82.16% and 54.16%) and pyridalyl (97.00% and 29.74%) at 5 µg/L and 200 µg/L pesticide concentration levels respectively. For PAHs, the sorption amounts were: naphthalene (22.03% and 48.00%), fluorene (38.99% and 39.00%), anthracene (64.62% and 68.02%) and pyrene (75.65% and 86.38%) at 5 µg/L and 200 µg/L PAH concentration levels respectively. Sorption was influenced by the octanol-water partition coefficient (log Kow) and ionic strength. Kinetics of the process in the case of sorption of pesticides were best explained by pseudo-first order kinetic model (R2 between 0.90 and 0.98) while the best fitting isotherm model was Dubinin-Radushkevich (R2 between 0.92 and 0.99). Results suggest the presence of surface level physi-sorption through a micropore volume filling mechanism and the role of hydrophobic and electrostatic forces. Pesticide desorption data in polyethylene mulch films indicate that pesticides with high log Kow were almost completely retained in mulch films, while those with lower log Kow were desorbed rapidly into the surrounding media. Our study highlights the role of microplastics from plastic mulch films as vectors for pesticide and PAH transport at environmentally realistic concentrations and the factors that influence it.


Assuntos
Praguicidas , Hidrocarbonetos Policíclicos Aromáticos , Poluentes Químicos da Água , Plásticos/química , Hidrocarbonetos Policíclicos Aromáticos/análise , Microplásticos/química , Agricultura , Polietileno/química , Adsorção , Poluentes Químicos da Água/análise
6.
Analyst ; 137(10): 2513-20, 2012 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-22500289

RESUMO

The molecular characteristics of chlorothalonil can cause particular determination difficulties in some vegetable commodities such as leek or garlic. These difficulties are mainly related to the low recoveries obtained using common multi-residue methods (MRMs)--a consequence of the very high interaction level with natural components in the matrix. These shortcomings were pointed out in the last European Proficiency Test for Pesticide Residues on Fruits and Vegetables, where false negatives for chlorothalonil in leek were observed at around 50%. In this study we have evaluated the ethyl acetate, the Dutch mini-Luke and the QuEChERS MRMs to compare their capabilities for chlorothalonil determination using GC-MS/MS in both the electron impact ionization (EI) and negative chemical ionization (NCI) modes. Best recoveries (in the range of 100-120%, with an RSD below 20%) were obtained using the Dutch mini-Luke method. Lower values (52-70%) were obtained for ethyl acetate whereas no recovery was obtained when the QuEChERS method was applied. Furthermore, tomato matrix was also included in the experiments in order to facilitate the comparability of results. Two ionization modes, electron impact ionization (EI) and negative chemical ionization (NCI) in GC-MS/MS, were applied to evaluate their respective advantages and disadvantages for quantification and identification. As expected, NCI showed limits of detection (LODs) 5 to 10 times lower than EI. However, in both cases, the LODs were still below 10 µg kg(-1). The proposed optimal method was applied for chlorothalonil determination in leek and garlic with good results--in accordance with the European Union (EU) Analytical Quality Control (AQC) Guidelines for pesticides analysis.


Assuntos
Contaminação de Alimentos/análise , Cromatografia Gasosa-Espectrometria de Massas , Nitrilas/análise , Resíduos de Praguicidas/análise , Verduras/química , Acetatos/química , Fracionamento Químico , Frutas/química , Nitrilas/isolamento & purificação , Resíduos de Praguicidas/isolamento & purificação
7.
Anal Bioanal Chem ; 402(3): 1365-72, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22101463

RESUMO

A gas chromatography-mass spectrometry method in negative chemical ionization mode has been developed incorporating simultaneous detection using a micro-electron capture detector (µ-ECD) for the determination of pesticides in fruits and vegetables. This instrument configuration uses a three-way splitter device which divides the effluent from the analytical column between the two detectors with the split ratio 1:0.1 (MSD/µ-ECD) in each run. The µ-ECD was used for confirmation purposes. Validation of the method was performed on three matrices: tomato, apple, and orange. The ethyl acetate method was assayed; recovery studies were performed at 10 and 100 µg/kg. Recoveries between 70% and 120% were achieved and relative standard deviations lower than 20% (n = 5) were obtained for all pesticides and matrices studied. Limits of quantification lower than 10 µg/kg were obtained for 100% of pesticides in all of the matrices. Limits of quantification lower than 2.5 µg/kg were achieved for 77.8% of pesticides in the tomato and apple matrices, and for 72.2% of pesticides in the orange matrix. The method showed linear response in the concentration range tested (2.5-500 µg/kg) with correlation coefficients >0.99. Good repeatability and reproducibility results were obtained in all cases, with relative standard deviations lower than 16.7% and 20%, respectively. Finally, 20 incurred samples were analyzed using the proposed method. The simultaneous use of the two detectors was satisfactory for the analysis of these real samples. The total number of pesticides identified was 25. The number of samples which contained at least one pesticide was 15-this represented 75% of the total number of samples studied.


Assuntos
Análise de Alimentos/métodos , Contaminação de Alimentos/análise , Frutas/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Praguicidas/análise , Verduras/química , Análise de Alimentos/instrumentação , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Limite de Detecção , Reprodutibilidade dos Testes
8.
Anal Bioanal Chem ; 402(2): 935-43, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22033822

RESUMO

Due to the basic properties of nicotine, it is not easily integrated into commonly used multiresidue methods. The present work investigates the application of two commonly employed multiresidue methods-the QuEChERS method and the ethyl acetate method-for determining nicotine in mushrooms. Both methods are employed in a modified form and an unmodified form: the former to address the special properties of nicotine and the latter, combined with the use of isotopically labelled nicotine, to compensate for poor recoveries. The QuEChERS-based methods were followed by liquid chromatography-time-of-flight mass spectrometry and those based on ethyl acetate extraction were followed by gas chromatography-triple quadrupole-mass spectrometry. All methods were validated according to European guidelines (document no. SANCO/10684/2009). Recovery studies performed on mushroom spiked at 10 and 100 µg kg(-1) yielded average recoveries in the range 80-110% with relative standard deviation (RSD) values below 9%. The linearity of the response over two orders of magnitude was demonstrated (r(2) > 0.995) for all of the determination techniques employed. The limits of detection and quantification obtained were in the 0.7 and 10 µg kg(-1) range, depending on the technique, and thus below the maximum residue level established for this toxic alkaloid by current EU legislation. Good repeatability and reproducibility were obtained in terms of the RSD of the analytical methods (0.4-13.2%). The modified QuEChERS method was tested in a proficiency test on nicotine in dried mushrooms obtaining good results. The methods were successfully applied to 20 real samples.


Assuntos
Agaricales/química , Nicotina/análise , Cromatografia Líquida de Alta Pressão , Cromatografia Gasosa-Espectrometria de Massas , Espectrometria de Massas , Reprodutibilidade dos Testes
9.
Anal Bioanal Chem ; 404(9): 2749-63, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22875538

RESUMO

This article presents a dose-response study of the effects of two types of third-generation (G3) and fourth-generation poly(amidoamine) (PAMAM) dendrimers on two cell lines (RTG-2 and H4IIE) by in vitro cytotoxicity assays with 3-(4,5-dimethylthizol-2-yl)-2,5-diphenyltetrazolium bromide (MTT), neutral red uptake (NRU), and lactate dehydrogenase (LDH) assays. We particularly investigated the potential cytotoxic effect of positive surface charge, which a cationic amino-terminated PAMAM dendrimer can display, on the marked ability of PAMAM dendrimers to cross the cell membrane compared with PAMAM dendrimers functionalized with chains of N-(2-hydroxydodecyl). Quantification of dose-response effects was performed by use of mass spectrometry analysis. The analytical method using liquid chromatography-hybrid quadrupole/time-of-flight mass spectrometry that we developed allowed characterization of defective dendrimers instead of "ideal structures." Identification was based on accurate mass measurement, assignment of elemental composition, and the fully resolved (13)C/(12)C isotopic clusters of the multiply charged ions of PAMAM dendrimers. Validation of the liquid chromatography-mass spectrometry method made possible reliable and reproducible quantification of the extracellular and intracellular concentration of dendrimers at a micromolar level (limits of detection from 0.14 to 1.34 µM and from 0.43 to 1.82 µM in standard and culture medium, respectively). A higher cytotoxicity was found with the H4IIE cell line for surface-modified PAMAM dendrimers. The LDH assay was significantly more sensitive than the MTT and NRU assays, with half-maximal inhibitory concentrations (IC(50)) of 12.96 and 38.31 µg mL(-1) for surface-modified G3 and G4 dendrimers, respectively. No cytotoxic effects, in terms of IC(50), of amino-terminated PAMAM dendrimers were observed on both H4IIE and RTG-2 cells when the concentration was below 500 µg mL(-1) for G3 and G4 dendrimers.

10.
Sci Total Environ ; 806(Pt 4): 150909, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34653474

RESUMO

Using reclaimed water to irrigate crops can be an important route for organic contaminants of emerging concern (CECs) to be introduced into agricultural production and thus find their way into the food chain. This work aims to establish accumulation models for the different parts of a crop (fruit/leaves/roots) and the soil of some of the most commonly detected CECs in reclaimed water, through field trials in greenhouses. For this, tomato plants were permanently irrigated under realistic agricultural conditions with a mixture of the selected compounds at approx. 1 µg/L. A total of 30 contaminants were analyzed belonging to different compound categories. A modified QuEChERS extraction method followed by liquid chromatography coupled to tandem mass spectrometry was the procedure used. The study revealed the presence of 21 target contaminants in the tomatoes, and 18 CECs in the leaves, roots, and soil. The average total concentration of pesticides detected in the tomatoes was 3 µg/kg f.w., whereas the average total load of pharmaceuticals was 5.8 µg/kg f.w. after three months, at the time of crop harvesting. The levels of pharmaceutical products and pesticides in the non-edible tissues were up to 3.5 and 2.1 µg/kg f.w., respectively, in the leaves and up to 89.3 and 31.3 µg/kg f.w., respectively, in the roots. In the case of the soil samples, the pesticide concentration found after crop harvesting was below 11.4 µg/kg d.w., and less than 3.0 µg/kg d.w. for pharmaceuticals. Overall, the concentration levels of CECs detected in the tomatoes, which were permanently irrigated with contaminated reclaimed water, do not pose a risk to human health via dietary intake.


Assuntos
Solanum lycopersicum , Poluentes Químicos da Água , Irrigação Agrícola , Cromatografia Líquida , Humanos , Espectrometria de Massas em Tandem , Águas Residuárias/análise , Água , Poluentes Químicos da Água/análise
11.
Water Sci Technol ; 63(10): 2123-30, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21977629

RESUMO

The system ozone and hydrogen peroxide was used to reclaim wastewater from the secondary clarifier from a Sewage Treatment Plant (STP) of Alcalá de Henares (Madrid-Spain). The assays were performed by bubbling a gas mixture of oxygen and ozone, with approximately 24 g Nm(-3) of ozone concentration, through a volume of wastewater samples for 20 minutes at 25 degrees C. The removal of dissolved micropollutants such as Pharmaceutical and Personal Care Products (PPCPs) and Organic Carbon (TOC) was enhanced by adding periodic pulses of hydrogen peroxide while keeping pH above 8.0 throughout the runs. Removal efficiency ratios in the range of 7-26 mg O3/mg TOC and 0.24 mg O3/ng micropollutants at 5 minutes of ozonation were assessed as reference data to reclaim wastewater from STP. The relation between the extent of TOC removed and ozone doses used was related by a second-order kinetic model in which the time-integrated ozone-hydrogen peroxide concentration was included.


Assuntos
Peróxido de Hidrogênio/química , Ozônio/química , Esgotos/química , Poluentes Químicos da Água/isolamento & purificação , Purificação da Água/métodos , Cinética , Modelos Químicos , Compostos Orgânicos/isolamento & purificação , Ozônio/análise , Preparações Farmacêuticas/isolamento & purificação , Reciclagem , Esgotos/análise
12.
Sci Total Environ ; 782: 146759, 2021 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-33838369

RESUMO

In this study, we aimed to develop and validate a quick, easy, and robust extraction method for the simultaneous determination of 30 organic contaminants of emerging concern (CECs) including some transformation products in soil samples. Three different extraction methods based on an ultrasonic cylindrical probe (UAE), a pressurized liquid extraction (PLE), and a QuEChERS method were compared. Ultra-performance liquid chromatography coupled with electrospray tandem mass spectrometry (LC-MS/MS) was used for identification and quantification of the target analytes. A modified QuEChERS method showed the best results in terms of extractability and accuracy. The extraction procedure developed provided adequate extraction performances (70% of the target analytes were recovered within a 70-99% range), with good repeatability and reproducibility (variations below 20%) and great sensitivity (LOQ < 0.1 ng/g in most cases). No matrix effects were observed for 70% of the compounds. Finally, the analytical methodology was applied in a pilot study where agricultural soil was irrigated with reclaimed water spiked with the contaminants under study. Of the 25 CECs added in irrigation water, a total of 13 pesticides and 5 pharmaceutical products were detected at concentration ranges from 0.1 to 1.2 ng/g (d.w) and from 0.1 to 2.0 ng/g (d.w), respectively.

13.
Anal Methods ; 13(36): 4131-4142, 2021 09 23.
Artigo em Inglês | MEDLINE | ID: mdl-34554152

RESUMO

In this study, we aimed to validate and apply a quick and easy extraction method for the simultaneous determination of 27 pesticide residues at trace levels in agricultural samples (soil, fruit, and leaf) to monitor the presence of these contaminants released from reclaimed water. The procedure was based on a salting-out extraction method with acidified acetonitrile, followed by a dispersive solid-phase extraction (d-SPE) clean-up step applying the C18 sorbent. Ultra-performance liquid chromatography coupled with electrospray tandem mass spectrometry (LC-MS/MS) was used for identification and quantification of the target analytes. This methodology provided recovery values higher than 70%, for all pesticides and matrices evaluated in the study, except for propamocarb in soil samples (35%). Repeatability and reproducibility results, calculated as relative standard deviations (RSD, %), ranged between 1% and 18% in both cases. No remarkable matrix effects were observed for vegetable samples, except for thiamethoxam in red cabbage, and hexythiazox in carrot and leaves (between 30 and 40%). Soil samples showed a moderate matrix effect (between 21 and 35%) for more than 80% of the compounds. Monitoring pesticide residues found in agricultural samples irrigated with contaminated reclaimed water under controlled conditions revealed the efficacy of the proposed method. Three common vegetables were grown to evaluate the different migration and distribution rates in crops and soil. Pesticide accumulation in the different parts of the crop (soil, fruit, and leaves) and the potential human exposure to pesticides through daily intake were also discussed.


Assuntos
Resíduos de Praguicidas , Cromatografia Líquida , Humanos , Resíduos de Praguicidas/análise , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem , Água
14.
Anal Bioanal Chem ; 397(7): 3061-70, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20571782

RESUMO

The obligation for accredited laboratories to participate in proficiency tests under ISO 17025, performing multiresidue methods (MRMs) for pesticide residues, involves the reporting of a large number of individual z scores making the evaluation of the overall performance of the laboratories difficult. It entails, time and again, the need for ways to summarise the laboratory's overall assessment into a unique combined index. In addition, the need for ways to continually evaluate the performance of the laboratory over the years is equally acknowledged. For these reasons, following 14 years of the European Union Reference Laboratory for Pesticide Residues in Fruits and Vegetables (EUPT-FV), useful formulas have been designed to globally evaluate the assessment of the participating laboratories. The aim is to achieve a formula which is easy to understand, which can be applied and which fits the purposes of long-term evaluation detecting positive and negative trends. Moreover, consideration is needed for a fair compensation of bad results in MRM, taking into account the large number of compounds that are covered. It is therefore important to be aware of the difficulties in getting satisfactory values from a wide range of compounds. This work presents an evaluation of the main well-established combined z score formulas together with those new ones developed here which have been applied to the European proficiency test results (EUPTs) over the years. Previous formulas such as the rescaled sum of z score (RSZ), the sum squared of z score (SSZ) and the relative laboratory performance (RLP) are compared with the newer ones: the sum of weighted z scores (SWZ) and the sum of squared z scores (SZ2). By means of formula comparisons, conclusions on the advantages, drawbacks and the most fit-for-purpose approach are achieved.


Assuntos
Técnicas de Laboratório Clínico/normas , Contaminação de Alimentos/análise , Frutas/química , Resíduos de Praguicidas/análise , Verduras/química , União Europeia , Estudos de Avaliação como Assunto
15.
Anal Bioanal Chem ; 397(1): 93-107, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20225064

RESUMO

Based on several alerts from European countries over the last years concerning spices, we have been encouraged to establish an accurate method for the determination of dyes, aflatoxins and pesticides in various types of spices using reversed-phase (RP) liquid chromatography-tandem mass spectrometry interfaced with electrospray (LC-ESI-MS/MS). A simple sample treatment procedure entailing the use of an extraction step with acetonitrile without further cleanup has been developed. A C18 column with an aqueous ammonium formate/methanol mixture as the mobile phase was used, and gradient elution was performed. Mass spectral acquisition was done in positive ion mode by applying multiple reaction monitoring of at least two fragmentation transitions per compound to provide a high degree of selectivity. The method was in-house validated in terms of linearity, sensitivity, repeatability, recovery and selectivity on six kinds of spices. Satisfactory results in the majority of the cases were obtained for all analytes and matrices, with practical limits of quantitation acceptable for routine monitoring purposes. Extraction recoveries for most of the compounds ranged from 60% to 140% at spiking levels of 0.05 and 0.5 mg kg(-1). The applicability of the method for the simultaneous determination of dyes, aflatoxins and pesticides in several types of spices was demonstrated, and the method successfully applied to a limited number of products from the local market.


Assuntos
Aflatoxinas/análise , Cromatografia Líquida de Alta Pressão , Corantes/análise , Praguicidas/análise , Espectrometria de Massas por Ionização por Electrospray , Especiarias/análise , Espectrometria de Massas em Tandem , Estudos de Validação como Assunto
16.
Anal Bioanal Chem ; 398(5): 2299-306, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20725716

RESUMO

This work reports a method for extraction and analysis of thiosultap sodium, thiocyclam, and nereistoxin in pepper. Different extraction methods were tested to attain the best recoveries. The final extraction method combines acetonitrile extraction in an acidic medium with ultrasonic extraction followed by a cleanup step with anhydrous MgSO(4). The analyses were performed on a Linear Ion Trap Quadrupole LC-MS/MS in negative mode for thiosultap sodium and in positive mode for thiocyclam and nereistoxin. Recovery studies carried out on peppers spiked at different fortification levels (20 and 200 µg∙kg(-1)) yielded average recoveries in the range 58-87% with RSD (%) values below 20%. Calibration curves covering two orders of magnitude were performed and they were linear over the concentration range studied (0.001-0.5 mg∙l(-1)). Instrumental detection limits were in the low µg∙kg(-1) range. Stability studies of thiosultap sodium in water were performed by evaluating a 100-µg∙l(-1) solution of this compound in water. It was analyzed over 7 days, after which more than 80% degradation of thiosultap sodium could be observed.


Assuntos
Cromatografia Líquida , Dissulfetos/análise , Compostos Heterocíclicos com 1 Anel/análise , Toxinas Marinhas/análise , Piper nigrum/química , Ácidos Sulfônicos/análise , Espectrometria de Massas em Tandem , Cromatografia Líquida/métodos , Inseticidas/análise , Espectrometria de Massas em Tandem/métodos
17.
Food Chem ; 274: 61-70, 2019 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-30372985

RESUMO

There is an increasing concern about the negative impacts of veterinary drugs in beehive compartments. This study evaluates the presence and distribution of chemical residues in beeswax, bee bread and honey and determinates in what extension honeybees are exposed to them. Samples were analyzed by LC-MS/MS and GC-MS/MS with a wide scope of 322 chemical residues. Samples were collected from apiaries located in rural and forest areas, showing no difference in contamination of phytosanitary applications. Residues of acaricides used for sanitary treatments, coumaphos and two transformation products of amitraz (DMF and DMPF), were quantified at higher levels in wax and bee bread than in honey in most cases. Coumaphos, DMF and DMPF were detected in honey in the range 6-36 µg.kg-1; 45-541 µg.kg-1; 15-107 µg.kg-1, respectively. All, except one sample, were below the EU MRLs, 396/2005 Regulation. Other pesticide residues were detected in beeswax and bee bread at various levels.


Assuntos
Análise de Alimentos/métodos , Mel/análise , Drogas Veterinárias/análise , Acaricidas/análise , Cromatografia Líquida/métodos , Cumafos/análise , Resíduos de Drogas/análise , Contaminação de Alimentos/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Resíduos de Praguicidas/análise , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos , Toluidinas/análise , Ceras/análise
18.
Sci Total Environ ; 647: 232-244, 2019 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-30081361

RESUMO

This study reports an analytical approach by gas chromatography and high-resolution mass spectrometry (HRMS) intended to be used for investigation of non-targeted environmental contaminants in honeybees. The approach involves a generic extraction and analysis with two GC-HRMS systems: time-of-flight and Orbitrap analyzers, GC-TOF-MS, and GC-Orbitrap-MS operated in electron-impact ionization (EI) mode. The workflow for screening of non-targeted contaminants consisted of initial peak detection by deconvolution and matching the first-stage mass spectra EI-MS with a nominal mass spectral library. To gain further confidence in the structural characterization of the contaminants under investigation, molecular formula of representative ions (molecular and fragment ions) was provided for those with an accurate mass scoring (error < 5 ppm). This methology was applied for screening environmental contaminants in 75 samples of adult honeybee. This approach has provided the tentative identification of environmental contaminants belonging to different chemical groups, among them, PAHs, phthalates and synthetic musks. Residues of veterinary treatments used in apiculture were also detected in the honeybee samples.


Assuntos
Abelhas/química , Monitoramento Ambiental/métodos , Poluentes Ambientais/análise , Animais , Cromatografia Gasosa-Espectrometria de Massas , Espectrometria de Massas , Compostos Orgânicos/análise , Hidrocarbonetos Policíclicos Aromáticos/análise
19.
J Chromatogr A ; 1215(1-2): 37-50, 2008 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-19036377

RESUMO

A rapid and sensitive liquid chromatography-tandem mass spectrometry method, in electrospray ionization positive mode, has been developed for the determination of 160 selected multi-class pesticides over a 33-min run time. Extracts were obtained using the acetonitrile-based QuEChERS (quick, easy, cheap, effective, rugged and safe) sample preparation technique. The validation study was carried out on tomato, pear and orange matrices following DG SANCO/2007/3131 of the European Quality Control Guidelines. These matrices represent high water, high sugar and high acidic content commodities, respectively. Matrix influence on recoveries and its effects on ionization were evaluated for the three matrices. Ten out of the 160 pesticides showed very low intensity, linearity and/or sensitivity problems. Linearity was studied in the 5-500 microg kg(-1) concentration range. Soft (<20%), medium (20-50%), and strong (>50%) matrix effects were obtained for 69%, 20%, and 11% of the studied compounds, respectively. Recoveries were investigated at the 10 and 100 microg kg(-1) levels, and depending on the commodity, 97%, 98% and 97% of the compounds in tomato, pear and orange, respectively, were in the 70-120% range. More than 90% of the investigated compounds had less or equal to a 5 microg kg(-1) limit of detection in the studied matrices. The relative standard deviations obtained exceeded 20% in only very few cases. The overall standard deviation obtained in the survey study (0.1551) was used for the method's uncertainty estimation. The expanded uncertainty resulted as being 0.3002 (coverage factor K=2, confidence level 95%). The method was applied on 59 real samples from 14 different kinds of fruits and vegetables. Thirty-three compounds were detected in 50 positive samples.


Assuntos
Cromatografia Líquida/métodos , Resíduos de Praguicidas/análise , Espectrometria de Massas em Tandem/métodos , Incerteza , Verduras/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
J Chromatogr A ; 1183(1-2): 38-48, 2008 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-18241873

RESUMO

In the present study the photocatalytic degradation of bezafibrate (BZF), a lipid regulator agent, has been investigated using TiO(2) suspensions and simulated solar light. The study focus on the identification of degradation products (DPs) using powerful analytical techniques such as liquid chromatography time of flight mass spectrometry (LC-TOF-MS), gas chromatography mass spectrometry (GC-MS), and high-performance liquid chromatography with diode-array detection (HPLC-DAD). Each technique provided complementary information that enabled the identification of 21 DPs. Accurate mass measurements obtained by LC-TOF-MS provided the elucidation of 17 DPs. Mass errors lower than 2mDa, allowed the assignment of empirical formula for the mayor DPs to be determined confidently. Three DPs were identified by GC-MS through the structural information provided by full scan mass spectra obtained by electron impact (EI) ionization and two more by HPLC-DAD by comparing the retention times (t(R)) and the UV spectra of the unknown DPs with those of commercial standards. Based on this by-product identification a possible multi-step degradation scheme was proposed. The pathways include single or multiple hydroxylation of BZF with subsequent phenoxy ring opening and the cleavage of the amide and ether bonds.


Assuntos
Bezafibrato/efeitos da radiação , Catálise , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida , Cromatografia Gasosa-Espectrometria de Massas , Fotoquímica , Espectrometria de Massas por Ionização por Electrospray , Titânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA