Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Mais filtros

País/Região como assunto
País de afiliação
Intervalo de ano de publicação
1.
Genet Mol Biol ; 43(1): e20180237, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31644681

RESUMO

Hepatitis C virus (HCV) infection is a worldwide health problem. Nowadays, direct-acting antiviral agents (DAAs) are the main treatment for HCV; however, the high level of virus variability leads to the development of resistance-associated variants (RAVs). Thus, assessing RAVs in infected patients is important for monitoring treatment efficacy. The aim of our study was to investigate the presence of naturally occurring resistance mutations in HCV NS3 and NS5 regions in treatment-naïve patients. Ninety-six anti-HCV positive serum samples from blood donors at the Center of Hematology and Hemotherapy of Santa Catarina State (HEMOSC) were collected retrospectively in 2013 and evaluated in this study. HCV 1a (37.9%), 1b (25.3%), and 3a (36.8%) subtypes were found. The frequency of patients with RAVs in our study was 6.9%. The HCV NS5b sequencing reveled 1 sample with L320F mutation and 4 samples with the C316N/R polymorphism. The analysis of the NS3 region revealed the D168A/G/T (3.45%), S122G (1.15%), and V55A (2.3%) mutations. All samples from genotype 3a (36.8%) presented the V170 I/V non-synonymous mutation. In conclusion, we have shown that mutations in NS3 and NS5b genes are present in Brazilian isolates from therapy-naïve HCV patients.

2.
Transfusion ; 58(4): 862-870, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29383720

RESUMO

BACKGROUND: The history of the development and implementation of the Brazilian nucleic acid testing (NAT) platform to detect and discriminate among human immunodeficiency virus (HIV), hepatitis C virus (HCV), and hepatitis B virus (HBV) infections in blood donors is described here. The results for the sensitivity, reproducibility, and NAT yield of the platform since program implementation are provided. STUDY DESIGN AND METHODS: The Brazilian NAT HIV, HCV, and HBV kit was developed and evaluated with regard to analytical sensitivity, specificity, intralot and interlot reproducibility, interfering substances, and genotype and diagnostic sensitivity. Additionally, a sample of identified NAT-yield cases was characterized with regard to viral load. RESULTS: The 95% limits of detection for HIV, HCV, and HBV were 68.02, 102.35, and 9.08 IU/mL, respectively. All replicates were detected with reproducibility assays between the acceptable values. A total of 13,610,536 blood donors was screened from 2010 to 2016, and 63 HIV-yield cases and 28 HCV-yield cases were detected. Among 5,795,424 blood donors screened for HBV from 2014 to 2016, 42 yield cases were found. CONCLUSION: The Brazilian NAT HIV, HCV, and HBV kit is an automated NAT system suitable for routine blood donor screening in a completely traceable process. The analytical sensitivity as well as the diagnostic sensitivity fulfilled all requirements set by the health ministry for blood donor screening. A significant number of transmission cases were prevented by the implementation of this important program.


Assuntos
Doadores de Sangue , Segurança do Sangue , DNA Viral/sangue , Infecções por HIV/diagnóstico , Hepatite B/diagnóstico , Hepatite C/diagnóstico , Reação em Cadeia da Polimerase em Tempo Real , Viremia/diagnóstico , Automação , Segurança do Sangue/instrumentação , Segurança do Sangue/métodos , Segurança do Sangue/normas , Brasil , Infecções por HIV/sangue , Hepatite B/sangue , Hepatite C/sangue , Humanos , Programas de Rastreamento/métodos , Reação em Cadeia da Polimerase em Tempo Real/instrumentação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reação em Cadeia da Polimerase em Tempo Real/normas , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Carga Viral , Viremia/transmissão
3.
J Clin Virol Plus ; 2(3): 100101, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35959109

RESUMO

There is a massive demand to identify alternative methods to detect new cases of COVID-19 as well as to investigate the epidemiology of the disease. In many countries, importation of commercial kits poses a significant impact on their testing capacity and increases the costs for the public health system. We have developed an ELISA to detect IgG antibodies against SARS-CoV-2 using a recombinant viral nucleocapsid (rN) protein expressed in E. coli. Using a total of 894 clinical samples we showed that the rN-ELISA was able to detect IgG antibodies against SARS-CoV-2 with high sensitivity (97.5%) and specificity (96.3%) when compared to a commercial antibody test. After three external validation studies, we showed that the test accuracy was higher than 90%. The rN-ELISA IgG kit constitutes a convenient and specific method for the large-scale determination of SARS-CoV-2 antibodies in human sera with high reliability.

4.
J Clin Virol Plus ; : 100103, 2022 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-35993012

RESUMO

There is a massive demand to identify alternative methods to detect new cases of COVID-19 as well as to investigate the epidemiology of the disease. In many countries, importation of commercial kits poses a significant impact on their testing capacity and increases the costs for the public health system. We have developed an ELISA to detect IgG antibodies against SARS-CoV-2 using a recombinant viral nucleocapsid (rN) protein expressed in E. coli. Using a total of 894 clinical samples we showed that the rN-ELISA was able to detect IgG antibodies against SARS-CoV-2 with high sensitivity (97.5%) and specificity (96.3%) when compared to a commercial antibody test. After three external validation studies, we showed that the test accuracy was higher than 90%. The rN-ELISA IgG kit constitutes a convenient and specific method for the large-scale determination of SARS-CoV-2 antibodies in human sera with high reliability.

5.
Braz J Infect Dis ; 25(2): 101542, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33587923

RESUMO

In response to the Zika epidemics in Brazil, the ZDC molecular assay (Bio-Manguinhos) was developed and registered at the Brazilian Regulatory Agency of Health Surveillance - ANVISA. The circulation of Zika (ZIKV) Dengue (DENV) and Chikungunya (CHIKV) viruses and their clinical similarities are challenges to correctly diagnose these viruses. The simultaneous detection of ZIKV, DENV and CHIKV is an important tool for diagnosis and surveillance. Here, we present the analytical and clinical performance evaluation of ZDC molecular assay (Bio-Manguinhos) at the public health laboratories three years after its registration at ANVISA. The clinical performance demonstrates the ZDC molecular assay (Bio-Manguinhos) has 100% sensitivity and 100% specificity to detect and discriminate ZIKV, CHIKV, and DENV from clinical plasma samples. The ZDC molecular assay (Bio-Manguinhos) results were highly reproducible and no cross-reactivity was seen during testing with a panel of other infectious agents. In conclusion, the ZDC molecular assay (Bio-Manguinhos) is an accurate and reliable tool to monitor Zika, dengue and chikungunya infections in countries like Brazil with simultaneous circulation of the three viruses.


Assuntos
Febre de Chikungunya , Vírus Chikungunya , Vírus da Dengue , Dengue , Infecção por Zika virus , Zika virus , Brasil , Febre de Chikungunya/diagnóstico , Vírus Chikungunya/genética , Dengue/diagnóstico , Vírus da Dengue/genética , Humanos , Laboratórios , Zika virus/genética , Infecção por Zika virus/diagnóstico
6.
Biomed Res Int ; 2020: 1803515, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32908871

RESUMO

Despite several available methodologies for Chagas disease (CD) serological screening, the main limitation of chronic CD diagnosis is the lack of effective tools for large-scale screening and point-of-care diagnosis to be used in different CD epidemiological scenarios. Taking into account that developing such a diagnostic tool will significantly improve the ability to identify CD carriers, we aimed at performing a proof-of-concept study (phase I study) to assess the use of these proteins in a point-of-care platform using serum samples from different geographical settings of Brazil and distinct clinical presentations. The diagnostic accuracy study was conducted on a panel of two WHO International Standards (IS) and 14 sera from T. cruzi-positive and 16 from T. cruzi-negative individuals. The results obtained with the test strips were converted to digital images, allowing quantitative comparison expressed as a relative band intensity ratio (RBI). The diagnostic potential and performance were also determined. Regardless of the geographical origin or clinical presentation, all sera with T. cruzi antibodies returned positive both for IBMP-8.1 and IBMP-8.4 chimeric antigens. The area under the ROC curve (AUC) values was 100% for both antigens, demonstrating an outstanding overall diagnostic accuracy (100%). Based on the data, we believe that the lateral flow assays based on these antigens are promising methodologies for screening CD.


Assuntos
Anticorpos Antiprotozoários/sangue , Antígenos de Protozoários/imunologia , Doença de Chagas/diagnóstico , Imunoensaio/métodos , Trypanosoma cruzi/imunologia , Antígenos de Protozoários/genética , Brasil , Doença de Chagas/imunologia , Doença de Chagas/parasitologia , Cromatografia de Afinidade/instrumentação , Cromatografia de Afinidade/métodos , Ensaio de Imunoadsorção Enzimática/instrumentação , Ensaio de Imunoadsorção Enzimática/métodos , Desenho de Equipamento , Humanos , Imunoensaio/instrumentação , Testes Imediatos , Estudo de Prova de Conceito , Proteínas de Protozoários/genética , Proteínas de Protozoários/imunologia , Proteínas Recombinantes de Fusão/genética , Proteínas Recombinantes de Fusão/imunologia , Trypanosoma cruzi/genética
7.
Braz J Infect Dis ; 22(5): 418-423, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30243981

RESUMO

The Brazilian Public Health Service provides freely αPEG-IFN to treat patients infected with HCV. The primary goal of HCV therapy is the long-term elimination of HCV from the blood to reduce the risk of HCV associated complications and death. Patient viremia affects the treatment duration and response, thus influencing clinical decisions. We developed a high-throughput method to perform the quantification of RNA hepatitis C virus (HCV) virus load in plasma samples to monitor patients under treatment. The method is based on a duplex detection, in a one-step real-time RT-PCR assay and it has been validated according to the rules established by the official Brazilian regulatory agency (ANVISA). This new method was compared to a commercial kit (Cobas/Taqman HCV Test v2.0 - Roche), showing virus load results with significant correlation between them (p = 0,012) using commercial and clinical panels. In addition, 611 samples from patients treated with peguilated alfa-interferon (αPEG-IFN) from different regions of Brazil were analyzed. Our one-step real-time RT-PCR assay demonstrated good performance in viral load measurement and in treatment course monitoring, with acceptable sensitivity and specificity values.


Assuntos
Hepacivirus/isolamento & purificação , Hepatite C/virologia , RNA Viral/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Carga Viral/métodos , Antivirais/uso terapêutico , Brasil , Genótipo , Técnicas de Genotipagem , Hepacivirus/genética , Hepatite C/sangue , Hepatite C/tratamento farmacológico , Humanos , Interferon-alfa/uso terapêutico , Polietilenoglicóis/uso terapêutico , Estudos Prospectivos , RNA Viral/sangue , RNA Viral/genética , Proteínas Recombinantes/uso terapêutico , Reprodutibilidade dos Testes , Fatores de Tempo , Viremia
8.
Acta Trop ; 102(3): 206-11, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17618860

RESUMO

Access to low-cost, effective diagnosis for leptospirosis is urgently needed in developing countries. The EIE-IgM-Leptospirose, a kit produced for public health laboratories in Brazil, was shown to have a sensitivity of 76% (77 of 102 patients) and 100% (102 of 102 patients) during acute and convalescent-phase leptospirosis, respectively, and a specificity of 93-100% (total healthy and patient control subjects evaluated, 486). These findings indicate that the assay will be useful for diagnosis of this emerging infectious disease in Brazil and other developing countries.


Assuntos
Ensaio de Imunoadsorção Enzimática , Imunoglobulina M/análise , Leptospirose/diagnóstico , Leptospirose/imunologia , Kit de Reagentes para Diagnóstico , Brasil/epidemiologia , Humanos , Leptospirose/epidemiologia , Sensibilidade e Especificidade , Testes Sorológicos
9.
Braz. j. infect. dis ; 25(2): 101542, 2021. tab
Artigo em Inglês | LILACS | ID: biblio-1278571

RESUMO

ABSTRACT In response to the Zika epidemics in Brazil, the ZDC molecular assay (Bio-Manguinhos) was developed and registered at the Brazilian Regulatory Agency of Health Surveillance - ANVISA. The circulation of Zika (ZIKV) Dengue (DENV) and Chikungunya (CHIKV) viruses and their clinical similarities are challenges to correctly diagnose these viruses. The simultaneous detection of ZIKV, DENV and CHIKV is an important tool for diagnosis and surveillance. Here, we present the analytical and clinical performance evaluation of ZDC molecular assay (Bio-Manguinhos) at the public health laboratories three years after its registration at ANVISA. The clinical performance demonstrates the ZDC molecular assay (Bio-Manguinhos) has 100% sensitivity and 100% specificity to detect and discriminate ZIKV, CHIKV, and DENV from clinical plasma samples. The ZDC molecular assay (Bio-Manguinhos) results were highly reproducible and no cross-reactivity was seen during testing with a panel of other infectious agents. In conclusion, the ZDC molecular assay (Bio-Manguinhos) is an accurate and reliable tool to monitor Zika, dengue and chikungunya infections in countries like Brazil with simultaneous circulation of the three viruses.


Assuntos
Humanos , Zika virus/genética , Infecção por Zika virus/diagnóstico , Brasil , Vírus Chikungunya/genética , Dengue/diagnóstico , Vírus da Dengue/genética , Febre de Chikungunya/diagnóstico , Laboratórios
10.
Biosens Bioelectron ; 19(2): 79-84, 2003 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-14568706

RESUMO

A polypeptide chain formed by recombinant antigens, cytoplasmic repetitive antigen (CRA) and flagellar repetitive antigen (FRA) (CF-Chimera) of Trypanosoma cruzi, was adsorbed on gold and platinum electrodes and investigated by electrochemical impedance spectroscopy on phosphate buffer saline solutions (PBS) containing a redox couple. It was found that the adsorption is strongly sensitive to the oxide layer on the electrode surface. In the majority of the experiments the antigens retained their activity as observed through their interaction with sera from chronic chagasic patients. The results expressed in terms of the charge transfer resistance across the interface, indicate the viability of using the impedance methodology for the development of a biosensor for serological diagnosis of Chagas' disease.


Assuntos
Anticorpos/sangue , Complexo Antígeno-Anticorpo/sangue , Técnicas Biossensoriais/instrumentação , Doença de Chagas/sangue , Doença de Chagas/diagnóstico , Impedância Elétrica , Eletrodos , Imunoensaio/instrumentação , Anticorpos/imunologia , Complexo Antígeno-Anticorpo/imunologia , Técnicas Biossensoriais/métodos , Doença de Chagas/imunologia , Materiais Revestidos Biocompatíveis/síntese química , Materiais Revestidos Biocompatíveis/química , Eletroquímica/instrumentação , Eletroquímica/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Ouro , Humanos , Imunoensaio/métodos , Metais , Platina , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Testes Sorológicos/instrumentação , Testes Sorológicos/métodos
11.
Braz. j. infect. dis ; 22(5): 418-423, Sept.-Oct. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-974233

RESUMO

ABSTRACT The Brazilian Public Health Service provides freely αPEG-IFN to treat patients infected with HCV. The primary goal of HCV therapy is the long-term elimination of HCV from the blood to reduce the risk of HCV associated complications and death. Patient viremia affects the treatment duration and response, thus influencing clinical decisions. We developed a high-throughput method to perform the quantification of RNA hepatitis C virus (HCV) virus load in plasma samples to monitor patients under treatment. The method is based on a duplex detection, in a one-step real-time RT-PCR assay and it has been validated according to the rules established by the official Brazilian regulatory agency (ANVISA). This new method was compared to a commercial kit (Cobas/Taqman HCV Test v2.0 - Roche), showing virus load results with significant correlation between them (p= 0,012) using commercial and clinical panels. In addition, 611 samples from patients treated with peguilated alfa-interferon (αPEG-IFN) from different regions of Brazil were analyzed. Our one-step real-time RT-PCR assay demonstrated good performance in viral load measurement and in treatment course monitoring, with acceptable sensitivity and specificity values.


Assuntos
Humanos , RNA Viral/isolamento & purificação , Hepatite C/virologia , Hepacivirus/isolamento & purificação , Carga Viral/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Antivirais/uso terapêutico , Polietilenoglicóis/uso terapêutico , Fatores de Tempo , Viremia , Proteínas Recombinantes/uso terapêutico , Brasil , RNA Viral/genética , RNA Viral/sangue , Estudos Prospectivos , Reprodutibilidade dos Testes , Interferon-alfa/uso terapêutico , Hepatite C/tratamento farmacológico , Hepatite C/sangue , Hepacivirus/genética , Técnicas de Genotipagem , Genótipo
12.
Artigo em Inglês | Arca: Repositório institucional da Fiocruz | ID: arc-39352

RESUMO

O Serviço de Saúde Pública do Brasil fornece αPEG-IFN gratuitamente para tratar pacientes infectados pelo HCV. O objetivo principal da terapia com HCV é a eliminação a longo prazo do HCV do sangue para reduzir o risco de complicações e morte associadas ao HCV. A viremia do paciente afeta a duração e a resposta do tratamento, influenciando assim as decisões clínicas. Desenvolvemos um método de alto rendimento para realizar a quantificação da carga do vírus do RNA da hepatite C (HCV) em amostras de plasma para monitorar pacientes em tratamento. O método baseia-se na detecção duplex, em um teste de RT-PCR em tempo real de uma etapa, e foi validado de acordo com as regras estabelecidas pela agência reguladora oficial do Brasil (ANVISA). Esse novo método foi comparado a um kit comercial (Teste Cobas / Taqman HCV v2.0 - Roche), mostrando resultados de carga de vírus com correlação significativa entre eles (p = 0,012) usando painéis comerciais e clínicos. Além disso, foram analisadas 611 amostras de pacientes tratados com interferon alfa peguilado (αPEG-IFN) de diferentes regiões do Brasil. Nosso teste de RT-PCR em tempo real de uma etapa demonstrou bom desempenho na medição da carga viral e no monitoramento do curso do tratamento, com valores aceitáveis ​​de sensibilidade e especificidade.


Assuntos
Anticorpos Anti-Hepatite C , Carga Viral , Reação em Cadeia da Polimerase em Tempo Real
14.
Hum Immunol ; 72(5): 402-5, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21371515

RESUMO

Previous works of our research group have demonstrated aspects of the humoral immune response of chronic Chagas disease using the cytoplasmatic repetitive antigen (CRA) and the flagellar repetitive antigen (FRA) of Trypanosoma cruzi. The aim of this work was to analyze the presence of specific immunoglobulin M (IgM) antibodies in chronic chagasic patients using these recombinant antigens of T. cruzi. The positivity of IgM in chronic chagasic patients against CRA and FRA antigens was determined by indirect enzyme-linked immunosorbent assay. We reported no statistical significant differences between the levels of IgM for both recombinant antigens and the different chronic clinical forms of Chagas disease. However, a small proportion of chronic chagasic patients analyzed in this study was positive for this antibody isotype. The findings of this study indicate that the IgM antibodies cannot be used to elucidate the differences in the profile of humoral immune response among chronic chagasic patients with different clinical forms using the CRA and FRA recombinant antigens of T. cruzi.


Assuntos
Antígenos de Protozoários/metabolismo , Doença de Chagas/diagnóstico , Doença de Chagas/imunologia , Imunoglobulina M/sangue , Proteínas de Protozoários/metabolismo , Trypanosoma cruzi/imunologia , Antígenos de Protozoários/genética , Antígenos de Protozoários/imunologia , Cardiomiopatia Chagásica , Doença de Chagas/classificação , Doença de Chagas/fisiopatologia , Doença Crônica , Progressão da Doença , Ensaio de Imunoadsorção Enzimática , Humanos , Prognóstico , Proteínas de Protozoários/genética , Proteínas de Protozoários/imunologia , Proteínas Recombinantes/genética , Trypanosoma cruzi/patogenicidade
15.
Clin Vaccine Immunol ; 18(5): 802-6, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21346054

RESUMO

Hepatitis C virus (HCV) infection is a major burden to public health worldwide, affecting approximately 3% of the human population. Although HCV detection is currently based on reliable tests, the field of medical diagnostics has a growing need for inexpensive, accurate, and quick high-throughput assays. By using the recombinant HCV antigens NS3, NS4, NS5, and Combined, we describe a new bead-based multiplex test capable of detecting HCV infection in human serum samples. The first analysis, made in a singleplex format, showed that each antigen coupled to an individual bead set presented high-level responses for anti-HCV-positive reference serum pools and lower-level responses for the HCV-negative pools. Our next approach was to determine the sensitivity and specificity of each antigen by testing 93 HCV-positive and 93 HCV-negative sera. When assayed in the singleplex format, the NS3, NS4, and NS5 antigens presented lower sensitivity values (50.5%, 51.6%, and 55.9%, respectively) than did the Combined antigen, which presented a sensitivity of 93.5%. All antigens presented 100% specificity. These antigens were then multiplexed in a 4-plex assay, which resulted in increased sensitivity and specificity values, performing with 100% sensitivity and 100% specificity. The positive and negative predictive values for the 4-plex assay were 100%. Although preliminary, this 4-plex assay showed robust results that, aligned with its small-sample-volume requirements and also its cost- and time-effectiveness, make it a reasonable alternative to tests currently used for HCV screening of potentially infected individuals.


Assuntos
Técnicas de Laboratório Clínico/métodos , Hepacivirus/imunologia , Anticorpos Anti-Hepatite C/sangue , Hepatite C/diagnóstico , Virologia/métodos , Antígenos Virais , Hepatite C/virologia , Humanos , Microesferas , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Soro/imunologia
16.
Hum Immunol ; 71(10): 964-7, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20659514

RESUMO

In the chronic phase of Chagas disease, individuals infected by Trypanosoma cruzi may be asymptomatic or may present cardiac and/or digestive complications. Our aim here was to analyze the relationship between the presence of specific immunoglobulin A antibodies and the different chronic clinical forms of Chagas disease using two recombinant antigens of Trypanosoma cruzi, cytoplasmatic repetitive antigen and flagellar repetitive antigen. The association of this immunoglobulin isotype with the digestive and cardio-digestive forms of the disease determined by indirect enzyme-linked immunosorbent assay, strongly suggests that IgA antibodies against these recombinant antigens of T. cruzi can be used as an immunological marker of the digestive alterations caused by Chagas disease. The tests performed in this study show that it is possible to differentiate digestive forms of Chagas disease. The knowledge provided by these results may help physicians to manage early alterations in the digestive tract of patients with the indeterminate or cardiac forms of Chagas disease. Prospective studies, however, with follow-up of the patients that presenting with high levels of immunoglobulin A against cytoplasmatic repetitive antigen and flagellar repetitive antigen recombinant antigens, need to be conducted to confirm this hypothesis.


Assuntos
Biomarcadores/sangue , Doença de Chagas/diagnóstico , Doença de Chagas/imunologia , Imunoglobulina A/sangue , Trypanosoma cruzi/imunologia , Adulto , Idoso , Antígenos de Protozoários/imunologia , Antígenos de Protozoários/metabolismo , Doença de Chagas/sangue , Doença de Chagas/fisiopatologia , Doença Crônica , Diagnóstico Diferencial , Doenças do Sistema Digestório , Progressão da Doença , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Proteínas de Protozoários/imunologia , Proteínas de Protozoários/metabolismo , Proteínas Recombinantes/metabolismo , Trypanosoma cruzi/patogenicidade
19.
J Clin Lab Anal ; 22(2): 91-8, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18348314

RESUMO

We propose to analyze the relation between the cellular immune response of Chagas' disease patients after in vitro stimulation of peripheral blood mononuclear cells (PBMC) with recombinant antigens cytoplasmatic repetitive antigen (CRA) or flagellar repetitive antigen (FRA) of T. cruzi and the chronic clinical forms of disease. Cells were stimulated using phytohemagglutinin, CRA, FRA, or a soluble antigen of Epimastigota (Ag-Epi) for 24 hr, 72 hr, or 6 days. The proliferation of cells was evaluated after 6 days of culture by quantification of incorporated 3H-thymidine. Cytokines were measured in the supernatants obtained after 24 hr (tumor necrosis factor [TNF]-alpha and interleukin [IL]-4), 72 hr (IL-10), and 6 days (interferon [IFN]-gamma) using enzyme-linked immunosorbent assay (ELISA). Cells of the Chagas patients stimulated with the recombinant antigens exhibited higher proliferation responses compared with that of non-Chagas (NC) individuals. However, when proliferation was compared between patients with the cardiac form (CF) or indeterminate form (IF), it was not possible to establish a difference in the response. So far as the cytokines secreted in the culture supernatants after stimulation in vitro with T. cruzi antigens were concerned, the results showed that CRA, as well as Epi-Ag, were able to stimulate the production of TNF-alpha and IFN-gamma in Chagas patients as compared with NC individuals. However, the cytokine levels after stimulation with the T. cruzi antigens were not different between the patients with CF and IF. CRA was capable of inducing a T helper type 1 (Th1) immune response, with elevated production of TNF-alpha and IFN-gamma in Chagas patients that are carriers of CF and IF clinical forms.


Assuntos
Antígenos de Protozoários/imunologia , Doença de Chagas/imunologia , Doença de Chagas/parasitologia , Imunidade Celular/imunologia , Proteínas Recombinantes/imunologia , Trypanosoma cruzi/imunologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Animais , Portador Sadio/parasitologia , Células Cultivadas , Feminino , Humanos , Imunidade Celular/efeitos dos fármacos , Interferon gama/imunologia , Interleucina-10/imunologia , Linfócitos/efeitos dos fármacos , Linfócitos/imunologia , Linfócitos/parasitologia , Masculino , Pessoa de Meia-Idade , Mitógenos/farmacologia , Frações Subcelulares/efeitos dos fármacos , Frações Subcelulares/parasitologia , Trypanosoma cruzi/efeitos dos fármacos , Fator de Necrose Tumoral alfa/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA