Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 97(3): 411-420, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-32198845

RESUMO

OBJECTIVES: We aimed to evaluate the use of bare metal stent (BMS) implantation in current percutaneous coronary intervention (PCI) era, focusing on indications for use and clinical outcomes. BACKGROUND: Limited data on BMS usage in current clinical practice are available. METHODS: All patients who underwent PCI with at least one BMS implantation in 18 Italian centers from January 1, 2013 to December 31, 2017, were included in our registry. Rates of BMS use and reasons for BMS implantations were reported for the overall study period and for each year. Primary outcomes were mortality, bleeding (Bleeding Academic Research Consortium-BARC and Thrombolysis in Myocardial Infarction-TIMI non-CABG definitions), and major adverse cardiac events (MACE) defined as the composite of all-cause and cardiac death, any myocardial infarction, target vessel revascularization, or any stent thrombosis. RESULTS: Among 58,879 patients undergoing PCI in the study period, 2,117 (3.6%) patients (mean age 73 years, 69.7% males, 73.3% acute coronary syndrome) were treated with BMS implantation (2,353 treated lesions). The rate of BMS implantation progressively decreased from 10.1% (2013) to 0.3% (2017). Main reasons for BMS implantation were: ST-elevation myocardial infarction (STEMI) (23.1%), advanced age (24.4%), and physician's perception of high-bleeding risk (34.0%). At a mean follow-up of 2.2 ± 1.5 years, all-cause and cardiac mortality were 25.6 and 12.7%, respectively; MACE rate was 35.3%, any bleeding rate was 13.0% (BARC 3-5 bleeding 6.3%, TIMI non-CABG major bleeding 6.1%). CONCLUSION: In a large, contemporary, real-world, multicenter registry, BMS use progressively reduced over the last 5 years. Main reasons for BMS implantation were STEMI, advanced age, and physician's perception of high-bleeding risk. High rates of mortality and MACE were observed in this real-world high-risk population.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Feminino , Humanos , Itália , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Stents , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 97(2): E227-E236, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32438488

RESUMO

BACKGROUND: The PARIS risk score (PARIS-rs) and percutaneous coronary intervention complexity (PCI-c) predict clinical and procedural residual ischemic risk following PCI. Their accuracy in patients undergoing unprotected left main (ULM) or bifurcation PCI has not been assessed. METHODS: The predictive performances of the PARIS-rs (categorized as low, intermediate, and high) and PCI-c (according to guideline-endorsed criteria) were evaluated in 3,002 patients undergoing ULM/bifurcation PCI with very thin strut stents. RESULTS: After 16 (12-22) months, increasing PARIS-rs (8.8% vs. 14.1% vs. 27.4%, p < .001) and PCI-c (15.2% vs. 11%, p = .025) were associated with higher rates of major adverse cardiac events ([MACE], a composite of death, myocardial infarction [MI], and target vessel revascularization), driven by MI/death for PARIS-rs and target lesion revascularization/stent thrombosis for PCI-c (area under the curves for MACE: PARIS-rs 0.60 vs. PCI-c 0.52, p-for-difference < .001). PCI-c accuracy for MACE was higher in low-clinical-risk patients; while PARIS-rs was more accurate in low-procedural-risk patients. ≥12-month dual antiplatelet therapy (DAPT) was associated with a lower MACE rate in high PARIS-rs patients, (adjusted-hazard ratio 0.42 [95% CI: 0.22-0.83], p = .012), with no benefit in low to intermediate PARIS-rs patients. No incremental benefit with longer DAPT was observed in complex PCI. CONCLUSIONS: In the setting of ULM/bifurcation PCI, the residual ischemic risk is better predicted by a clinical risk estimator than by PCI complexity, which rather appears to reflect stent/procedure-related events. Careful procedural risk estimation is warranted in patients at low clinical risk, where PCI complexity may substantially contribute to the overall residual ischemic risk.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Fatores de Risco , Stents , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 96(1): 1-9, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31860158

RESUMO

OBJECTIVES: To evaluate the independent clinical impact of stent structural features in a large cohort of patients undergoing unprotected left main (ULM) or coronary bifurcation percutaneous coronary intervention (PCI) with a range of very thin strut stents. BACKGROUND: Clinical impact of structural features of contemporary stents remains to be defined. METHODS: All consecutive patients enrolled in the veRy thin stents for patients with left mAIn or bifurcatioN in real life (RAIN) registry were included. The following stent structural features were studied: antiproliferative drugs (everolimus vs. sirolimus vs. zotarolimus), strut material (platinum-chromium vs. cobalt-chromium), polymer (bioresorbable vs. durable), number of crowns (<8 vs. ≥8) and number of connectors (<3 vs. ≥3). For small diameter stents (≤2.5 mm), struct thickness (74 vs. 80/81 µm) was also tested. Target lesion failure (TLF), a composite of target lesion revascularization and stent thrombosis, was the primary endpoint. Multivariate analysis was performed with Cox regression models. RESULTS: Out of 2,707 patients, 110 (4.1%) experienced a TLF event after 16 months (12-18). After adjustment for confounders, an increased number of connectors (adjusted hazard ratio [adj-HR] 0.62, 95% confidence interval (CI) 0.39-0.99, p = .04) reduced risk of TLF, driven by stents with ≥2.5 mm diameter (HR 0.54, 95% CI 0.32-0.93, p = .02). This independent relationship was lost for stents with diameter <2.5 mm, where only strut thickness appeared to impact. Conversely, no independent relationship of polymer type, number of crowns, and the specific limus-family eluted drug with outcomes was observed. CONCLUSIONS: Among a range of contemporary very thin stent models, an increased number of connectors improved device-related outcomes in this investigated high-risk procedural setting.


Assuntos
Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 89(4): 763-772, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27567013

RESUMO

OBJECTIVES: To compare indications and clinical outcomes of two contemporary left atrial appendage (LAA) percutaneous closure systems in a "real-world" population. BACKGROUND: Percutaneous LAA occlusion is an emerging therapeutic option for stroke prevention in atrial fibrillation. Some questions however remain unanswered, such as the applicability of results of randomized trials to current clinical practice. Moreover, currently available devices have never been directly compared. METHODS: We retrospectively analyzed consecutive patients who underwent LAA closure at San Raffaele Hospital, Milan, Italy between 2009 and 2015. Clinical indications and device selection were left to operators' decision; routine clinical and transesophageal echocardiography (TEE) follow-up was performed. RESULTS: One-hundred and sixty-five patients were included in the study, of which 99 were treated with the Amplatzer Cardiac Plug (ACP) and 66 with the Watchman system. During the follow-up period (median 15 months, interquartile range 6-26 months) five patients died. The incidence of ischemic events was low, with one patient suffering a transient ischemic attack and no episodes recorded of definitive strokes. Twenty-six leaks ≥1 mm were detected (23%); leaks were less common with the ACP and with periprocedural three-dimensional TEE evaluation, but were not found to correlate with clinical events. Clinical outcomes were comparable between the two devices. CONCLUSIONS: Our data show excellent safety and efficacy of LAA closure, irrespectively of the device utilized, in a population at high ischemic and hemorrhagic risk. The use of ACP and 3D-TEE minimized the incidence of residual leaks; however, the clinical relevance of small peri-device flow warrants further investigation. © 2016 Wiley Periodicals, Inc.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral/prevenção & controle , Cirurgia Assistida por Computador/métodos , Idoso , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Incidência , Itália/epidemiologia , Masculino , Desenho de Prótese , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 87(5): 884-92, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26308750

RESUMO

OBJECTIVES: To identify predictors of restenosis after recanalization of chronic total occlusions (CTOs) with the Subintimal Tracking And Reentry (STAR) technique. BACKGROUND: STAR is associated with high rates of restenosis but the associated factors are not clear. Understanding the underlying mechanisms may be important to improve STAR outcomes and possibly other contemporary CTO recanalization techniques utilizing extensive subintimal dissection and stenting. METHODS: We retrospectively analyzed 211 lesions that underwent a STAR procedure (between 2002 and 2013) with a final Thrombolysis in Myocardial Infarction (TIMI) flow grade 2 or 3. One-hundred and nineteen lesions that received drug eluting stents (DES) and underwent follow-up angiography were included in the final analysis. RESULTS: Of the 119 lesions treated with DES following STAR, 75 restenoses were observed (63.0%). Utilizing multivariate analysis, TIMI flow grade in the recanalized artery following stent implantation at the end of the index procedure was the only independent predictor of restenosis. CONCLUSIONS: Following recanalization of a CTO with STAR, final TIMI flow predicted future restenosis or reocclusion. As a bailout technique, STAR resulted in a high acute success rate with good safety and acceptable long-term results. When poor flow is observed following recanalization, and prior to stent implantation, a two-step strategy whereby a second procedure is performed at an interval to maximize coronary flow at the end of the procedure may be considered with the goal to reduce the risk of future restenosis or total vessel occlusion following STAR.


Assuntos
Circulação Coronária , Oclusão Coronária/terapia , Reestenose Coronária/etiologia , Vasos Coronários/fisiopatologia , Intervenção Coronária Percutânea/efeitos adversos , Idoso , Velocidade do Fluxo Sanguíneo , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/fisiopatologia , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/fisiopatologia , Reestenose Coronária/prevenção & controle , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/instrumentação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 87(5): 832-6, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26331577

RESUMO

OBJECTIVES: To investigate clinical outcomes following target lesion revascularization (TLR) for bioresorbable scaffold (BRS) failure in a real world population. BACKGROUND: BRS has become a new option in percutaneous coronary intervention, and may be potentially advantages because of the absence of a permanent metallic cage and the possibility for restoration of vasomotion and endothelial function. However, the requirement for TLR following BRS has been reported, but data on outcomes following reintervention are currently lacking. METHODS: Eighteen patients (20 lesions) who underwent TLR for BRS failure were identified at two high-volume centers in Milan, Italy. Clinical outcomes including all cause death, myocardial infarction, and repeat TLR after TLR for BRS failure were examined. RESULTS: The type of scaffold failure at TLR was classified into focal pattern in 15 lesions, diffuse pattern in two lesions, restenosis at side branch ostium in one lesion and scaffold thrombosis in two lesions. TLR was treated with plain old balloon angioplasty (POBA) in two lesions, with drug-coating balloon in three lesions, drug eluting stent implantation in 11 lesions, further BRS implantation in four lesions. During the followup (median: 345 days after TLR), one sudden death and three repeat TLRs were observed. CONCLUSION: In our series, we observed an adverse event rate of 20% of during the followup period following TLR for BRS failure. The optimal treatment option for these patients remains to be determined.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão , Doença da Artéria Coronariana/terapia , Reestenose Coronária/terapia , Trombose Coronária/terapia , Intervenção Coronária Percutânea/instrumentação , Falha de Prótese , Adulto , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/mortalidade , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/etiologia , Trombose Coronária/mortalidade , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Feminino , Hospitais com Alto Volume de Atendimentos , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Retratamento , Fatores de Risco , Fatores de Tempo , Falha de Tratamento
7.
Catheter Cardiovasc Interv ; 87(7): 1306-13, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26945697

RESUMO

OBJECTIVES: The aim of this study was to assess the effect of a novel hourglass-shaped balloon on reduction of paravalvular leak (PVL) in patients undergoing transcatheter aortic valve replacement (TAVR) with self-expanding prostheses. BACKGROUND: An important limitation of TAVR compared with surgical aortic valve replacement remains the higher incidence of PVL. A commonly used strategy to treat PVL is balloon postdilatation (BPD); however, the optimal technique for treating PVL after TAVR is unknown. METHODS: We examined consecutive patients with severe, symptomatic aortic stenosis who underwent TAVR with the Medtronic CoreValve followed by BPD with an InterValve V8 balloon for PVL grade ≥2+. Data from echocardiographic, multidetector computed tomographic, and angiographic images were reviewed. The primary endpoint was successful reduction in PVL to grade 1+ or less as assessed by intraprocedural echocardiography. RESULTS: Eleven patients were studied (median age, 82 years; 64% female). Ten patients (91%) demonstrated successful reduction in PVL after V8 BPD. In three patients, PVL was reduced to zero or trace. PVL remained unchanged in one patient (2+). Two patients had complete heart block associated with valve deployment and received permanent pacemakers. There were no occurrences of annular injury or major adverse clinical events. CONCLUSIONS: BPD with the V8 hourglass-shaped balloon was feasible in reducing PVL from self-expanding TAVR prostheses. © 2016 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/terapia , Valvuloplastia com Balão/instrumentação , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Falha de Prótese , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Angiografia por Tomografia Computadorizada , Ecocardiografia Doppler em Cores , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Retratamento , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 85(1): E10-5, 2015 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-24909303

RESUMO

OBJECTIVES: To compare the early clinical outcomes between ABSORB bioresorbable vascular scaffold (BVS) (Abbott Vascular, Santa Clara, CA) and cobalt chromium everolimus-eluting stents in real-world patients with mostly complex disease. BACKGROUND: BVS represents the most interesting development in the drug-eluting stent field over recent years with promising results emerging from clinical trials. Available data however on the use of the ABSORB in real-world patients is limited. METHODS: All patients (n = 92) treated with BVS and 1296 patients treated with EES were included in this study. Propensity score matching was performed to adjust for differences in baseline clinical characteristics, yielding 92 patient pairs (BVS = 92 patients with 137 lesions and EES = 92 patients with 124 lesions). Clinical outcomes were examined between the 2 groups at 6-months. RESULTS: In both groups, most lesions were classified as either B2 or C (83.9% vs. 77.4%, P = 0.19). Predilatation (97.8% vs. 75.8%, P < 0.01) as well as postdilation (99.3% vs. 77.4%, P < 0.01) was more common in the BVS group. Clinical outcomes at 6-months were similar between the two groups with respect to both target lesion revascularization (3.3% vs. 5.4%, P = 0.41) and major adverse cardiac events (defined as the composite of target vessel revascularization, follow-up myocardial infraction and all-cause death) (3.3% vs. 7.6%, P = 0.19). CONCLUSIONS: ABSORB BVS for the treatment of complex lesions appears to be associated with good procedural and early clinical outcomes similar to those observed with conventional drug-eluting stents. Larger studies with long-term follow-up are required in order to fully assess the role of BVS in the treatment of such lesions and how this compares with that of conventional stents. © 2014 Wiley Periodicals, Inc.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Sirolimo/análogos & derivados , Stents , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Distribuição de Qui-Quadrado , Ligas de Cromo , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Everolimo , Feminino , Humanos , Itália , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Pontuação de Propensão , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Sirolimo/administração & dosagem , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento , Ultrassonografia de Intervenção
9.
Catheter Cardiovasc Interv ; 86(4): 644-52, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26013748

RESUMO

The aim of this study was to investigate clinical outcomes of patients treated with a provisional stenting (PS) versus a double stenting (DS) strategy for coronary bifurcation lesions with bioresorbable scaffolds (BRS). There are limited data available with regards to outcomes following BRS implantation for bifurcation lesions. A total of 132 bifurcation lesions treated with BRS between 2012 and 2014 were analyzed. Of the total of 132 bifurcation lesions, 10 lesions were treated without crossover stenting. 99 lesions (81%) were treated with a PS strategy and 23 lesions (19%) with a DS strategy. The DS group consisted of patients with a greater number of true bifurcation lesions (PS 52.0% vs. DS 91.3%: P < 0.001). In the PS group, seven lesions (7.1%) were crossed-over to T-stenting. In the DS group, 13 lesions (57%) were treated with BRS to the side branch (SB). A hybrid stenting technique [BRS to the main branch, and metallic drug-eluting stent (DES) to the SB] was utilized in 10 (43%) lesions. Target lesion revascularization (TLR) rates were 5.5% for PS and 11.2% for DS (P = 0.49) at 1-year follow-up. Definite scaffold thrombosis did not occur at the site of any bifurcation lesion. These findings suggest that BRS implantation for bifurcation lesions is technically feasible. The rates of TLR tended to be higher in the DS group compared to when a PS strategy was employed. Larger studies are eagerly awaited to determine longer-term follow-up of this treatment strategy.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/métodos , Estenose Coronária/terapia , Stents , Idoso , Angioplastia Coronária com Balão/mortalidade , Distribuição de Qui-Quadrado , Estudos de Coortes , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Estatísticas não Paramétricas , Taxa de Sobrevida , Alicerces Teciduais , Resultado do Tratamento , Ultrassonografia de Intervenção
10.
Catheter Cardiovasc Interv ; 83(4): 530-8, 2014 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-23983065

RESUMO

BACKGROUND: Unprotected distal left main trifurcation (ULMT) lesion represents a challenge for interventional cardiologists with the potential for peri-procedural complications and adverse events at follow-up especially when the main branch and the side branches are concomitantly diseased. METHODS: A retrospective cohort analysis was performed on consecutive patients with ULMT stenosis who electively underwent percutaneous coronary intervention (PCI) with drug-eluting stent (DES) implantation in order to assess the technical feasibility and long-term outcomes according to the disease distribution in the trifurcation branches (true vs. non-true ULMT). Primary endpoint of the study was a composite of major adverse cardiovascular events (MACE) defined as cardiac-death, myocardial infarction (MI), and target lesion revascularization (TLR) during follow-up. RESULTS: Eighty-four patients underwent PCI with DES for ULMT disease during the study period (40 true trifurcation and 44 non-true trifurcation). Angiographic and procedural success were obtained in 94% and 92.8% of cases. At 3-years follow-up, the occurrence of MACE was significantly higher in patients with true ULMT than in those with non-true ULMT (HR 2.801 [confidence interval; CI 1.164-7.896], P = 0.025) due to a higher TLR rate (HR 3.032 [CI 1.164-7.896], P = 0.023). No episodes of late and very late definite/probable stent thrombosis (ST) occurred. On multivariable analysis, a true-ULMT lesion was the only independent predictor of MACE (HR 2.344 [C.I. 1.006-5.461], P = 0.049). CONCLUSIONS: PCI with DES for ULMT stenosis is feasible with a high procedural success rate and no definite/probable ST reported at follow-up. A true trifurcation lesion is associated with enhanced risk of MACE mainly driven by TLR.


Assuntos
Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Idoso , Distribuição de Qui-Quadrado , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Intervalo Livre de Doença , Estudos de Viabilidade , Feminino , Humanos , Itália , Japão , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Modelos de Riscos Proporcionais , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 83(6): 889-95, 2014 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-23804318

RESUMO

OBJECTIVES: To compare biodegradable polymer biolimus-eluting (BES) with abluminal drug elution and durable polymer everolimus-eluting (EES) stents in the treatment of bifurcation lesions. BACKGROUND: The persistence of a polymer in drug-eluting stents (DES) following drug elution has been viewed as a possible culprit for restenosis. DES with biodegradable polymer may thus be associated with improved clinical outcomes, especially in high-risk lesions such as those at bifurcation sites. METHODS: We performed a retrospective study of consecutive de novo bifurcation lesions treated with EES between October 2006 and October 2011 and BES between February 2008 and March 2012. Study endpoints included major adverse cardiac events (MACE) defined as all-cause death, myocardial infarction (MI), including peri-procedural MI, and target vessel revascularization (TVR) as well as target lesion revascularization (TLR) separately. RESULTS: We analyzed 236 bifurcation lesions treated with either BES (79 lesions in 69 patients) or EES (157 lesions in 154 patients). Patient and procedural characteristics were broadly similar between the two groups. Estimated MACE and TVR rates at 2-year follow-up were similar between the BES and EES groups (MACE = 13.6 ± 4.6% vs. 14.6 ± 3.2% (P = 0.871); TVR = 6.9 ± 3.5% vs. 8.0 ± 2.7% (P = 0.889). No significant differences were noted between the two groups following propensity-score matched analysis. There was no probable or definite stent thrombosis. CONCLUSION: BES use in the treatment of bifurcation lesions appears to be associated with good clinical outcomes, comparable to those seen with EES, at long-term follow-up. These results are hypothesis-generating and need to be validated with larger studies.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Polímeros , Sirolimo/análogos & derivados , Idoso , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Everolimo , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento
12.
Catheter Cardiovasc Interv ; 83(1): 156-61, 2014 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-23475626

RESUMO

OBJECTIVE: To compare radial and femoral crossover techniques (CT) for vascular access management in transcatheter aortic valve implantation (TAVI). BACKGROUND: Femoral crossover for controlled angiography and balloon inflation of the therapeutic access site to facilitate safe vascular closure is beneficial but technically challenging in patients with complex femoral anatomy. An alternative approach should be available. METHODS: Between June 2011 and March 2012, 41 transfemoral TAVI patients receiving the femoral CT were compared to 46 transfemoral TAVI patients receiving the radial CT. Outcomes were 30-day valve academic research consortium (VARC) endpoints. RESULTS: Patients undergoing the radial CT received higher median contrast volumes (150 interquartile range [IQR]: 105-180 vs. 111 IQR: 90-139 ml; P = 0.025) but procedural radiation dose and fluoroscopy times were comparable. Thirty day all cause and cardiovascular death were similar between radial and femoral CT groups (respectively 2.4% vs. 7.9%, P = 0.258 and 0% vs. 7.9%, P = 0.063). There were no differences in major vascular complications (4.3% vs. 7.3%, P = 0.553), life threatening or major bleeding events (respectively 9.1% vs. 19.5%, P = 0.168 and 13.6% vs. 22%, P = 0.315). CONCLUSION: In TAVI cases with unfavorable contralateral femoral anatomy, radial CT for vascular access management is a reasonable alternative to the femoral CT.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco , Cateterismo Periférico , Artéria Femoral , Implante de Prótese de Valva Cardíaca , Hemorragia/prevenção & controle , Técnicas Hemostáticas , Artéria Radial , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemorragia/etiologia , Técnicas Hemostáticas/efeitos adversos , Técnicas Hemostáticas/mortalidade , Humanos , Masculino , Punções , Radiografia Intervencionista , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
13.
J Interv Cardiol ; 27(4): 348-55, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24815951

RESUMO

OBJECTIVES: To report a single-center experience of drug-eluting balloons (DEB) in the treatment of in-stent restenosis (ISR) and de novo coronary artery disease. BACKGROUND: DEB are emerging as an alternative treatment for coronary stenosis especially when metal scaffolding is undesirable (in-stent restenosis and small-vessel de novo disease). Although there are various randomized trials and registry studies, the data from real-world cohorts are lacking. METHODS: Consecutive patients treated with the In.Pact Falcon™ (Medtronic Inc., Minneapolis, MN, USA) paclitaxel-eluting balloon between January 2009 and December 2011 were retrospectively studied. The measured end-points were cardiac death, myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), and major adverse cardiac events (MACE) defined as combination of cardiac death, MI, and TVR. RESULTS: A total of 275 lesions were successfully treated in 184 patients. The mean age was 66.2 ± 9.6 years, and 87% were males. The predominant indication for DEB use was ISR (62%), with de novo lesions accounting for the remainder (38%). A mean of 1.48 ± 0.9 DEB were used per patient. Bailout stenting was required in 24% of lesions. The median clinical follow-up was 14.6 months (IQR 12-23). The overall rates of cardiac death, MI, TLR, TVR, and MACE were 3.8%, 1.6%, 16.8%, 17.9%, and 21.7%, respectively. The overall rate of stent thrombosis was 0.5% (n = 1). CONCLUSION: Our results suggests that DEB can be considered in lesions where the use of stents is not desirable, especially restenotic lesions. Further long-term follow-up of these patients will provide us more insights on the long-term outcomes.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/terapia , Reestenose Coronária/terapia , Stents/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Fármacos Cardiovasculares/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Paclitaxel/administração & dosagem , Avaliação de Resultados da Assistência ao Paciente , Sistema de Registros , Estudos Retrospectivos
14.
J Am Coll Cardiol ; 2024 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-39480378

RESUMO

BACKGROUND: Side branch stenting is often required during provisional stenting, leading to suboptimal results. Drug-coated balloons (DCB) for the compromised side branch have emerged as an attractive strategy. However, the benefit of DCB for coronary bifurcations remains unclear. OBJECTIVES: This study aimed to investigate whether DCB, compared with a noncompliant balloon (NCB), for the pinched side branch improves the outcomes of provisional stenting in patients with simple, true coronary bifurcations. METHODS: In this multicenter, randomized controlled trial, patients with true coronary bifurcations who had side branch diameter stenosis of ≥70% after main vessel stenting at 22 centers in China, Indonesia, Italy, and Korea were randomly assigned to either DCB or NCB intervention. The primary endpoint was major adverse cardiac events, a composite of cardiac death, target vessel myocardial infarction, or clinically driven target-lesion revascularization at the 1-year follow-up. RESULTS: Between September 8, 2020, and June 2, 2023, 784 patients with true coronary bifurcation lesions undergoing main vessel stenting and having a severely compromised side branch were randomly assigned to the DCB (n = 391) or NCB (n = 393) group. One-year follow-up was completed in all patients. The primary endpoint occurred in 28 patients in the DCB group and 49 patients in the NCB group (Kaplan-Meier rate: 7.2% vs 12.5%; HR: 0.56; 95% CI: 0.35-0.88; P = 0.013), driven by a reduction in myocardial infarction. There were no significant differences between groups in procedural success, crossover to a 2-stent approach, all-cause death, revascularization, or stent thrombosis. CONCLUSIONS: In patients with simple and true coronary bifurcation lesions undergoing provisional stenting, main vessel stenting with a DCB for the compromised side branch resulted in a lower 1-year rate of the composite outcome compared with an NCB intervention for the side branch. The high rates of periprocedural myocardial infarction, which occurred early and did not lead to revascularization, are of unclear clinical significance.

15.
Catheter Cardiovasc Interv ; 81(5): 810-7, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22899552

RESUMO

This case series raises further awareness of the potential for longitudinal shortening with the Promus Element™ (Boston Scientific, MN) drug-eluting stent (DES) platform. With safety at the forefront of DES development, newer generation systems are utilizing thinner platforms with little or no polymer. Although these contemporary, ultrathin platforms also improve conformability and deliverability, specific design characteristics might inadvertently reduce longitudinal strength. To date, there are no randomized data addressing this issue in vivo for any stent platform, with opinion based on individual experience and bench testing. We report five cases of longitudinal shortening with the Promus Element stent occurring in our institution over a 15-month period. During the same period, we experienced only isolated cases with other second generation DES platforms. Our experience supports recently published bench-top data correlating the two-link design of this platform with the risk of compression.


Assuntos
Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Falha de Prótese , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Risco , Estresse Mecânico , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção
16.
J Interv Cardiol ; 26(3): 259-63, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23373592

RESUMO

OBJECTIVES: To assess the safety and efficacy of combining drug-eluting balloon (DEB) and drug-eluting stents (DES) in the same coronary lesion. BACKGROUND: Use of DEB may not always produce optimal results or even result in dissection, compelling the operators to consider bailout stenting with bare metal stents (BMS). However, BMS may not be ideal in patients who have significant risk-profile for restenosis. We have opted for DES over BMS in such situations and present our follow-up data. METHODS: Between 2009 and 2011, 46 patients (57 lesions) requiring bailout stenting following DEB use were treated with second-generation DES. All patients had at-least one or more risk-factors that made them vulnerable for restenosis (diabetes, chronic kidney disease, previous in-stent restenosis [ISR], and/or long diffuse lesions ≥ 30 mm). RESULTS: Of the 57 lesions, 34 (60%) were previous ISR. The mean length of the DEB was: 36.2 ± 5.6 mm. All patients had TIMI-3 flow post PCI with no in-lab complications. At median follow-up of 12.3 months (interquartile range [IQR]: 7.5-18.1), the rates target lesion revascularization (TLR) and target vessel revascularization (TVR) were 3 (5.3%) and 4 (7%), respectively. One patient had died 3 months following treatment. There were no episodes of myocardial infarction, definite or probable stent thrombosis. The major adverse cardiovascular events (MACE) rate defined as cardiac-death, MI, and TVR occurred in 11% of patients. CONCLUSION: The results from this novel strategy of combining "Paclitaxel" eluting balloon and "Limus" eluting stent in a same lesion are encouraging. Dual drug-elution acting on two different pathways may provide potential synergy that may explain the favorable outcome.


Assuntos
Angioplastia Coronária com Balão , Implante de Prótese Vascular , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Paclitaxel/uso terapêutico , Intervenção Coronária Percutânea/métodos , Moduladores de Tubulina/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Taxa de Sobrevida , Resultado do Tratamento
17.
J Clin Ultrasound ; 41(3): 195-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-22457261

RESUMO

Inherited connective tissue diseases such as Marfan syndrome are frequently associated with cardiovascular manifestations. Aortic involvement with dilation and dissection is the most common finding and the major cause of death in Marfan syndrome patients. We report the echocardiographic study of a 53-year-old male patient with uncommon coexistence of cardiovascular abnormalities typical of connective tissue disease at first clinical presentation in acute clinical setting: dissection of the descending aorta associated with severe mitral regurgitation due to leaflet flail and massive aortic insufficiency due to ascending aortic enlargement, leading to left ventricular dilation and dysfunction.


Assuntos
Aneurisma da Aorta Torácica/diagnóstico por imagem , Dissecção Aórtica/diagnóstico por imagem , Ecocardiografia Doppler em Cores , Síndrome de Marfan/complicações , Insuficiência da Valva Mitral/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , Dissecção Aórtica/etiologia , Aneurisma da Aorta Torácica/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/etiologia , Disfunção Ventricular Esquerda/etiologia
18.
Am Heart J ; 164(6): 910-7, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23194492

RESUMO

BACKGROUND: Limited real-world data comparing outcomes after transcatheter (TAVR) and surgical aortic valve replacement (SAVR) in intermediate-surgical-risk patients with aortic stenosis are available. METHODS: We identified 182 consecutive patients who underwent TAVR via the transfemoral (TF) route (November 2007-February 2011) and 111 moderate-to-high-risk historical case controls undergoing SAVR (August 2003-July 2008). Using propensity score matching based on clinical characteristics and surgical risk scores, we compared clinical outcomes in 111 matched patients. Valve Academic Research Consortium definitions were applied for end point adjudication. RESULTS: Baseline clinical characteristics, in particular Logistic European System for Cardiac Operative Risk Evaluation (23.2 ± 15.1 vs 24.4 ± 13.4) and Society of Thoracic Surgeons score (4.6 ± 2.3 vs 4.6 ± 2.6), were well matched between groups. Transfemoral TAVR was associated with more vascular complications (33.3% vs 0.9%, P < .001). On the other hand, acute kidney injury was more frequent after SAVR (8.1% vs 26.1%, P < .001). The rates of all-cause mortality in both TF-TAVR and SAVR groups was1.8% at 30 days (P = 1.00) and 6.4% and 8.1%, respectively, at 1 year (P = .80). At 1 year, the rate of cerebrovascular events was similar in the 2 groups (4.6% vs 9.1%, P = .19). CONCLUSIONS: In this real-world cohort of intermediate-surgical-risk patients with aortic stenosis, TF-TAVR and SAVR were associated with similar mortality rates during follow-up but with a different spectrum of periprocedural complications. Furthermore, the survival rate after TF-TAVR in this group of elderly patients with intermediate Society of Thoracic Surgeons score was encouraging.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco , Estudos de Casos e Controles , Estudos de Coortes , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Complicações Pós-Operatórias , Pontuação de Propensão , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento
19.
Catheter Cardiovasc Interv ; 79(1): 20-7, 2012 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-21805559

RESUMO

AIM: There are limited data on the mid-term safety following the use of the guided-subintimal tracking and re-entry (guided-STAR) technique for the treatment of chronic total occlusions (CTO) and concerns have arisen about a potential increased risk of stent thrombosis (ST). OBJECTIVES: The aim of this study was to evaluate the mid-term safety in terms of cardiac death and ST after recanalization using the contrast guided-STAR technique when compared to conventional anterograde CTO recanalization (CA-CTO). METHODS AND RESULTS: This retrospective study analyzed 355 consecutive patients with successful angiographic recanalization (residual stenosis <20% and TIMI flow grade ≥2) of CTO lesion. Seventy-four (20.8%) underwent guided-STAR and 281 (79.2%) had CA-CTO. Survival rates were estimated using the Kaplan-Meier method. Compared to CA-CTO patients, the rate of the following clinical, angiographic, and procedural characteristics were significantly higher in guided-STAR patients: hypercholesterolemia (84 vs. 67%, P = 0.004), previous CABG (41.3 vs. 15.7%, P < 0.0001), three-vessel disease, (62.7 vs. 47%, P = 0.019), right coronary artery CTO (62.7 vs. 41.6%, P = 0.002), stent length (68.15 vs. 54.05 mm, P < 0.0001). A drug-eluting stent was implanted in the majority of cases (89.2% guided-STAR vs. 93.5% CA-CTO). At a median follow-up of 779 days (IQR 495-1035), there were no significant differences in cardiac survival (97.2 vs. 97.5%, Log-rank P = 0.912) and cumulative ARC ST rates (2.8 vs. 1.8%, Log-rank P = 0.610) for guided-STAR and CA-CTO patients, respectively. The rate of restenosis was significantly higher in the guided-STAR group compared to the CA-CTO group (54 vs. 30%, Log-rank P < 0.0001). The adjusted Cox proportional-hazard analysis for procedural technique showed that the only significant independent predictor of restenosis was the stent length (HR, 1.017; 95% CI, 1.008-1.027; P < 0.0001). CONCLUSION: At mid-term follow-up, the guided-STAR was not inferior to CA-CTO in terms of safety. The only significant independent predictor of restenosis was the stent length.


Assuntos
Angioplastia Coronária com Balão/métodos , Oclusão Coronária/terapia , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/mortalidade , Distribuição de Qui-Quadrado , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/mortalidade , Reestenose Coronária/etiologia , Stents Farmacológicos , Feminino , Humanos , Itália , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
20.
Am J Cardiol ; 172: 18-25, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35365291

RESUMO

The association of left ventricular ejection fraction (LVEF) with procedural and long-term outcomes after state-of-the-art percutaneous coronary intervention (PCI) of bifurcation lesions remains unsettled. A total of 5,333 patients who underwent contemporary coronary bifurcation PCI were included in the intercontinental retrospective combined insights from the unified RAIN (veRy thin stents for patients with left mAIn or bifurcatioN in real life) and COBIS (COronary BIfurcation Stenting) III bifurcation registries. Of 5,003 patients (93.8%) with known baseline LVEF, 244 (4.9%) had LVEF <40% (bifurcation with reduced ejection fraction [BIFrEF] group), 430 (8.6%) had LVEF 40% to 49% (bifurcation with mildly reduced ejection fraction [BIFmEF] group) and 4,329 (86.5%) had ejection fraction (EF) ≥50% (bifurcation with preserved ejection fraction [BIFpEF] group). The primary end point was the Kaplan-Meier estimate of major adverse cardiac events (MACEs) (a composite of all-cause death, myocardial infarction, and target vessel revascularization). Patients with BIFrEF had a more complex clinical profile and coronary anatomy. No difference in procedural (30 days) MACE was observed across EF categories, also after adjustment for in-study outcome predictors (BIFrEF vs BIFmEF: adjusted hazard ratio [adj-HR] 1.39, 95% confidence interval [CI] 0.37 to 5.21, p = 0.626; BIFrEF vs BIFpEF: adj-HR 1.11, 95% CI 0.25 to 2.87, p = 0.883; BIFmEF vs BIFpEF: adj-HR 0.81, 95% CI 0.29 to 2.27, p = 0.683). BIFrEF was independently associated with long-term MACE (median follow-up 21 months, interquartile range 10 to 21 months) than both BIFmEF (adj-HR 2.20, 95% CI 1.41 to 3.41, p <0.001) and BIFpEF (adj-HR 1.91, 95% CI 1.41 to 2.60, p <0.001) groups, although no difference was observed between BIFmEF and BIFpEF groups (adj-HR 0.87, 95% CI 0.61 to 1.24, p = 0.449). In conclusion, in patients who underwent PCI of a coronary bifurcation lesion according to contemporary clinical practice, reduced LVEF (<40%), although a strong predictor of long-term MACEs, does not affect procedural outcomes.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Disfunção Ventricular Esquerda , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA