Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Microsurgery ; 44(1): e31088, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37665032

RESUMO

BACKGROUND: Lymphedema constitutes a major unsolved problem in plastic surgery. To identify novel lymphedema treatments, preclinical studies are vital. The surgical mouse lymphedema model is popular and cost-effective; nonetheless, a synthesis and overview of the literature with evidence-based guidelines is needed. The aim of this review was to perform a systematic review to establish best practice and support future high-quality animal studies exploring lymphedema treatments. METHODS: We performed a systematic review following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, searching four databases (PubMed, Embase, Web of Science, and Scopus) from inception-September 2022. The Animals in Research Reporting In Vivo Experiments 2.0 (ARRIVE 2.0) guidelines were used to evaluate reporting quality. Studies claiming to surgically induce lymphedema in the hindlimb of mice were included. RESULTS: Thirty-seven studies were included. Four main models were used. (1) Irradiation+surgery. (2) A variation of the surgery used by (1) + irradiation. (3) Surgery only (SPDF-model). (4) Surgery only (PLND-model). Remaining studies used other techniques. The most common measurement modality was the caliper. Mean quality coefficient was 0.57. Eighteen studies (49%) successfully induced sustained lymphedema. Combination of methods seemed to yield the best results, with an overrepresentation of irradiation, the removal of two lymph nodes, and the disruption of both the deep and superficial lymph vessels in the 18 studies. CONCLUSION: Surgical mouse hindlimb lymphedema models are challenged by two related problems: (1) retaining lymphedema for an extended period, that is, establishing a (chronic) lymphedema model (2) distinguishing lymphedema from post-operative edema. Most studies failed to induce lymphedema and used error-prone measurements. We provide an overview of studies claiming to induce lymphedema and advocate improved research via five evidence-based recommendations to use: (1) a proven lymphedema model; (2) sufficient follow-up time, (3) validated measurement methods; (4) ARRIVE-guidelines; (5) contralateral hindlimb as control.


Assuntos
Vasos Linfáticos , Linfedema , Camundongos , Animais , Linfedema/etiologia , Linfedema/cirurgia , Linfedema/patologia , Linfonodos/cirurgia , Vasos Linfáticos/patologia , Membro Posterior/cirurgia , Extremidade Inferior , Modelos Animais de Doenças
2.
Eur Arch Otorhinolaryngol ; 280(1): 97-103, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35612611

RESUMO

PURPOSE: Temporal bone surgery requires excellent surgical skills and simulation-based training can aid novices' skills acquisition. However, simulation-based training is challenged by early stagnation of performance after few performances. Structured self-assessment during practice might enhance learning by inducing reflection and engagement in the learning task. In this study, structured self-assessment was introduced during virtual reality (VR) simulation of mastoidectomy to investigate the effects on subsequent performance during cadaveric dissection. METHODS: A prospective educational study with comparison with historical controls (reference cohort). At a temporal bone dissection course, eighteen participants performed structured self-assessment during 3 h of VR simulation mastoidectomy training before proceeding to cadaver dissection (intervention cohort). At a previous course, eighteen participants received identical VR simulation training but without the structured self-assessment (reference cohort). Final products from VR simulation and cadaveric dissection were recorded and assessed by two blinded raters using a 19-point modified Welling Scale. RESULTS: The intervention cohort completed fewer procedures (average 4.2) during VR simulation training than the reference cohort (average 5.7). Nevertheless, the intervention cohort achieved a significantly higher average performance score both in VR simulation (11.1 points, 95% CI [10.6-11.5]) and subsequent cadaveric dissection (11.8 points, 95% CI [10.7-12.8]) compared with the reference cohort, who scored 9.1 points (95% CI [8.7-9.5]) during VR simulation and 5.8 points (95% CI [4.8-6.8]) during cadaveric dissection. CONCLUSIONS: Structured self-assessment is a valuable learning support during self-directed VR simulation training of mastoidectomy and the positive effect on performance transfers to subsequent cadaveric dissection performance.


Assuntos
Otolaringologia , Treinamento por Simulação , Humanos , Mastoidectomia/educação , Estudos Prospectivos , Processo Mastoide/cirurgia , Autoavaliação (Psicologia) , Otolaringologia/educação , Simulação por Computador , Treinamento por Simulação/métodos , Cadáver , Competência Clínica
3.
Eur Arch Otorhinolaryngol ; 279(7): 3269-3288, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35166908

RESUMO

PURPOSE: 3D-printing (three-dimensional printing) is an emerging technology with promising applications for patient-specific interventions. Nonetheless, knowledge on the clinical applicability of 3D-printing in otology and research on its use remains scattered. Understanding these new treatment options is a prerequisite for clinical implementation, which could improve patient outcomes. This review aims to explore current applications of 3D-printed patient-specific otologic interventions, including state of the evidence, strengths, limitations, and future possibilities. METHODS: Following the PRISMA statement, relevant studies were identified through Pubmed, EMBASE, the Cochrane Library, and Web of Science. Data on the manufacturing process and interventions were extracted by two reviewers. Study quality was assessed using Joanna Briggs Institute's critical appraisal tools. RESULTS: Screening yielded 590 studies; 63 were found eligible and included for analysis. 3D-printed models were used as guides, templates, implants, and devices. Outer ear interventions comprised 73% of the studies. Overall, optimistic sentiments on 3D-printed models were reported, including increased surgical precision/confidence, faster manufacturing/operation time, and reduced costs/complications. Nevertheless, study quality was low as most studies failed to use relevant objective outcomes, compare new interventions with conventional treatment, and sufficiently describe manufacturing. CONCLUSION: Several clinical interventions using patient-specific 3D-printing in otology are considered promising. However, it remains unclear whether these interventions actually improve patient outcomes due to lack of comparison with conventional methods and low levels of evidence. Further, the reproducibility of the 3D-printed interventions is compromised by insufficient reporting. Future efforts should focus on objective, comparative outcomes evaluated in large-scale studies.


Assuntos
Otolaringologia , Impressão Tridimensional , Humanos , Próteses e Implantes , Reprodutibilidade dos Testes
4.
Eur Arch Otorhinolaryngol ; 279(1): 127-136, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33604749

RESUMO

PURPOSE: To develop and gather validity evidence for a novel tool for assessment of cochlear implant (CI) surgery, including virtual reality CI surgery training. METHODS: Prospective study gathering validity evidence according to Messick's framework. Four experts developed the CI Surgery Assessment Tool (CISAT). A total of 35 true novices (medical students), trained novices (residents) and CI surgeons performed two CI-procedures each in the Visible Ear Simulator, which were rated by three blinded experts. Classical test theory and generalizability theory were used for reliability analysis. RESULTS: The CISAT significantly discriminated between the three groups (p < 0.001). The generalizability coefficient was 0.76 and most of the score variance (53.3%) was attributable to the participant and only 6.8% to the raters. When exploring a standard setting for CI surgery, the contrasting groups method suggested a pass/fail score of 36.0 points (out of 55), but since the trained novices performed above this, we propose using the mean CI surgeon performance score (45.3 points). CONCLUSION: Validity evidence for simulation-based assessment of CI performance supports the CISAT. Together with the standard setting, the CISAT might be used to monitor progress in competency-based training of CI surgery and to determine when the trainee can advance to further training.


Assuntos
Implantes Cocleares , Realidade Virtual , Competência Clínica , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes
5.
Eur Arch Otorhinolaryngol ; 278(7): 2313-2320, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32909062

RESUMO

PURPOSE: At graduation from medical school, competency in otoscopy is often insufficient. Simulation-based training can be used to improve technical skills, but the suitability of the training model and assessment must be supported by validity evidence. The purpose of this study was to collect content validity evidence for a simulation-based test of handheld otoscopy skills. METHODS: First, a three-round Delphi study was conducted with a panel of nine clinical teachers in otorhinolaryngology (ORL) to determine the content requirements in our educational context. Next, the authenticity of relevant cases in a commercially available technology-enhanced simulator (Earsi, VR Magic, Germany) was evaluated by specialists in ORL. Finally, an integrated course was developed for the simulator based on these results. RESULTS: The Delphi study resulted in nine essential diagnoses of normal variations and pathologies that all junior doctors should be able to diagnose with a handheld otoscope. Twelve out of 15 tested simulator cases were correctly recognized by at least one ORL specialist. Fifteen cases from the simulator case library matched the essential diagnoses determined by the Delphi study and were integrated into the course. CONCLUSION: Content validity evidence for a simulation-based test of handheld otoscopy skills was collected. This informed a simulation-based course that can be used for undergraduate training. The course needs to be further investigated in relation to other aspects of validity and for future self-directed training.


Assuntos
Competência Clínica , Treinamento por Simulação , Simulação por Computador , Alemanha , Humanos , Otoscopia
6.
Eur Arch Otorhinolaryngol ; 277(5): 1335-1341, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32067096

RESUMO

PURPOSE: Ultra-high-fidelity (UHF) graphics in virtual reality (VR) simulation might improve surgical skill acquisition in temporal bone training. This study aims to compare UHF VR simulation training with conventional, screen-based VR simulation training (cVR) with respect to performance and cognitive load (CL). METHODS: In a randomized trial with a cross-over design, 24 students completed a total of four mastoidectomies in a VR temporal bone surgical simulator: two performances under UHF conditions using a digital microscope and two performances under conventional conditions using screen-based VR simulation. Performances were assessed by two blinded raters using an established assessment tool. In addition, CL was estimated as the relative change in secondary-task reaction time during simulation when compared with individual baseline measurements. Data were analyzed using linear mixed model analysis for repeated measurements. RESULTS: The mean final-product performance score was significantly lower in UHF VR simulation compared to cVR simulation [mean difference 1.0 points out of 17 points, 95% CI (0.2-1.7), p = 0.02]. The most important factor for performance during UHF simulation was the ability to achieve stereovision (mean difference = 3.4 points, p < 0.001). Under the UHF VR condition, CL was significantly higher than during cVR (28% vs. 18%, respectively, p < 0.001). CONCLUSION: UHF graphics in VR simulation training reduced performance and induced a higher CL in novices than conventional, screen-based VR simulation training. Consequently, UHF VR simulation training should be preceded by cVR training and might be better suited for the training of intermediates or experienced surgeons.


Assuntos
Mastoidectomia , Treinamento por Simulação , Realidade Virtual , Competência Clínica , Simulação por Computador , Feminino , Humanos , Masculino , Processo Mastoide/cirurgia , Interface Usuário-Computador
7.
Eur Arch Otorhinolaryngol ; 276(10): 2783-2789, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31350598

RESUMO

PURPOSE: Virtual reality (VR) training of mastoidectomy is effective in surgical training-particularly if organized as distributed practice. However, centralization of practice facilities is a barrier to implementation of distributed simulation training. Decentralized training could be a potential solution. Here, we aim to assess the feasibility, use, and barriers to decentralized VR mastoidectomy training using a freeware, high-fidelity temporal bone simulator. METHODS: In a prospective, mixed-methods study, 20 otorhinolaryngology residents were given three months of local access to a VR mastoidectomy simulator. Additionally, trainees were provided a range of learning supports for directed, self-regulated learning. Questionnaire data were collected and focus group interviews conducted. The interviews were analyzed using thematic analysis and compared with quantitative findings. RESULTS: Participants trained 48.5 h combined and mainly towards the end of the trial. Most participants used between two and four different learning supports. Qualitative analysis revealed five main themes regarding implementation of decentralized simulation training: convenience, time for training, ease of use, evidence for training, and testing. CONCLUSIONS: Decentralized VR training using a freeware, high-fidelity mastoidectomy simulator is feasible but did not lead to a high training volume or truly distributed practice. Evidence for training was found motivational. Access to training, educational designs, and the role of testing are important for participant motivation and require further evaluation.


Assuntos
Simulação por Computador , Mastoidectomia/educação , Treinamento por Simulação/métodos , Realidade Virtual , Adulto , Competência Clínica , Humanos , Internato e Residência , Otolaringologia/educação , Estudos Prospectivos
9.
Simul Healthc ; 18(4): 219-225, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-36260767

RESUMO

INTRODUCTION: Reliability is pivotal in surgical skills assessment. Video-based assessment can be used for objective assessment without physical presence of assessors. However, its reliability for surgical assessments remains largely unexplored. In this study, we evaluated the reliability of video-based versus physical assessments of novices' surgical performances on human cadavers and 3D-printed models-an emerging simulation modality. METHODS: Eighteen otorhinolaryngology residents performed 2 to 3 mastoidectomies on a 3D-printed model and 1 procedure on a human cadaver. Performances were rated by 3 experts evaluating the final surgical result using a well-known assessment tool. Performances were rated both hands-on/physically and by video recordings. Interrater reliability and intrarater reliability were explored using κ statistics and the optimal number of raters and performances required in either assessment modality was determined using generalizability theory. RESULTS: Interrater reliability was moderate with a mean κ score of 0.58 (range 0.53-0.62) for video-based assessment and 0.60 (range, 0.55-0.69) for physical assessment. Video-based and physical assessments were equally reliable (G coefficient 0.85 vs. 0.80 for 3D-printed models and 0.86 vs 0.87 for cadaver dissections). The interaction between rater and assessment modality contributed to 8.1% to 9.1% of the estimated variance. For the 3D-printed models, 2 raters evaluating 2 video-recorded performances or 3 raters physically assessing 2 performances yielded sufficient reliability for high-stakes assessment (G coefficient >0.8). CONCLUSIONS: Video-based and physical assessments were equally reliable. Some raters were affected by changing from physical to video-based assessment; consequently, assessment should be either physical or video based, not a combination.


Assuntos
Competência Clínica , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Gravação em Vídeo , Simulação por Computador , Cadáver
10.
Otol Neurotol ; 44(7): e497-e503, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37442608

RESUMO

OBJECTIVE: 3-D printing offers convenient and low-cost mastoidectomy training; nonetheless, training benefits using 3-D-printed temporal bones remain largely unexplored. In this study, we have collected validity evidence for a low-cost, 3-D-printed temporal bone for mastoidectomy training and established a credible pass/fail score for performance on the model. STUDY DESIGN: A prospective educational study gathering validity evidence using Messick's validity framework. SETTING: Seven Danish otorhinolaryngology training institutions. PARTICIPANTS: Eighteen otorhinolaryngology residents (novices) and 11 experienced otosurgeons (experts). INTERVENTION: Residents and experienced otosurgeons each performed two to three anatomical mastoidectomies on a low-cost, 3-D-printed temporal bone model produced in-house. After drilling, mastoidectomy performances were rated by three blinded experts using a 25-item modified Welling scale (WS). MAIN OUTCOME MEASURE: Validity evidence using Messick's framework including reliability assessment applying both classical test theory and Generalizability theory. RESULTS: Novices achieved a mean score of 13.9 points; experienced otosurgeons achieved 23.2 points. Using the contrasting groups method, we established a 21/25-point pass/fail level. The Generalizability coefficient was 0.91, and 75% of the score variance was attributable to participant performance, indicating a high level of assessment reliability. Subsequent D studies revealed that two raters rating one performance or one rater rating two performances were sufficiently reliable for high-stakes assessment. CONCLUSION: Validity evidence supports using a low-cost, 3-D-printed model for mastoidectomy training. The model can be printed in-house using consumer-grade 3-D printers and serves as an additional training tool in the temporal bone curriculum. For competency-based training, we established a cut-off score of 21 of 25 WS points using the contrasting groups method.


Assuntos
Otolaringologia , Treinamento por Simulação , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Osso Temporal/cirurgia , Mastoidectomia/métodos , Otolaringologia/educação , Treinamento por Simulação/métodos , Competência Clínica
11.
3D Print Med ; 9(1): 12, 2023 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-37062800

RESUMO

BACKGROUND: 3D-printed temporal bone models can potentially provide a cost-effective alternative to cadaver surgery that can be manufactured locally at the training department. The objective of this study was to create a cost-effective 3D-printed model suitable for mastoidectomy training using entry level and commercially available print technologies, enabling individuals, without prior experience on 3D-printing, to manufacture their own models for basic temporal bone training. METHODS: Expert technical professionals and an experienced otosurgeon identified the best material for replicating the temporal bone and created a cost-effective printing routine for the model using entry-level print technologies. Eleven participants at a temporal bone dissection course evaluated the model using a questionnaire. RESULTS: The 3D-printed temporal bone model was printed using a material extrusion 3D-printer with a heat resistant filament, reducing melting during drilling. After printing, a few simple post-processing steps were designed to replicate the dura, sigmoid sinus and facial nerve. Modifying the 3D-printer by installing a direct-drive and ruby nozzle resulted in more successful prints and less need for maintenance. Upon evaluation by otorhinolaryngology trainees, unanimous feedback was that the model provided a good introduction to the mastoidectomy procedure, and supplementing practice to cadaveric temporal bones. CONCLUSION: In-house production of a cost-effective 3D-printed model for temporal bone training is feasible and enables training institutions to manufacture their own models. Further, this work demonstrates the feasibility of creating new temporal bone models with anatomical variation to provide ample training opportunity.

12.
Injury ; 54(5): 1321-1329, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36907823

RESUMO

BACKGROUND: Resuscitative endovascular balloon occlusion of the aorta (REBOA) is an emerging and potentially life-saving procedure, necessitating qualified operators in an increasing number of centres. The procedure shares technical elements with other vascular access procedures using the Seldinger technique, which is mastered by doctors not only in endovascular specialties but also in trauma surgery, emergency medicine, and anaesthesiology. We hypothesised that doctors mastering the Seldinger technique (experienced anaesthesiologist) would learn the technical aspects of REBOA with limited training and remain technically superior to doctors unfamiliar with the Seldinger technique (novice residents) given similar training. METHODS: This was a prospective trial of an educational intervention. Three groups of doctors were enroled: novice residents, experienced anaesthesiologists, and endovascular experts. The novices and the anaesthesiologists completed 2.5 h of simulation-based REBOA training. Their skills were tested before and 8-12 weeks after training using a standardised simulated scenario. The endovascular experts, constituting a reference group, were equivalently tested. All performances were video recorded and rated by three blinded experts using a validated assessment tool for REBOA (REBOA-RATE). Performances were compared between groups and with a previously published pass/fail cutoff. RESULTS: Sixteen novices, 13 board-certified specialists in anaesthesiology, and 13 endovascular experts participated. Before training, the anaesthesiologists outperformed the novices by 30 percentage points of the maximum REBOA-RATE score (56% (SD 14.0) vs 26% (SD 17%), p<0.01). After training, there was no difference in skills between the two groups (78% (SD 11%) vs 78 (SD 14%), p = 0.93). Neither group reached the endovascular experts' skill level (89% (SD 7%), p<0.05). CONCLUSION: For doctors mastering the Seldinger technique, there was an initial inter-procedural transfer of skills advantage when performing REBOA. However, after identical simulation-based training, novices performed equally well to anaesthesiologists, indicating that vascular access experience is not a prerequisite to learning the technical aspects of REBOA. Both groups would need more training to reach technical proficiency.


Assuntos
Oclusão com Balão , Procedimentos Endovasculares , Choque Hemorrágico , Humanos , Estudos Prospectivos , Hemorragia/terapia , Procedimentos Endovasculares/métodos , Aorta/cirurgia , Oclusão com Balão/métodos , Ressuscitação/métodos , Catéteres
13.
Arch Plast Surg ; 49(4): 538-542, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35919550

RESUMO

Performing the first peer review of a plastic surgical research article can be an overwhelming task. However, it is an essential scholarly skill and peer review is used in a multitude of settings: evaluation of journal articles, conference abstracts, and research proposals. Furthermore, peer reviewing provides more than just the opportunity to read and help improve other's work: peer reviewing can improve your own scientific writing. A structured approach is possible and recommended. In these ten tips, we provide guidance on how to successfully conduct the first peer reviews. The ten tips on peer reviewing concern: 1) Appropriateness: are you qualified and prepared to perform the peer review? 2) Familiarization with the journal and its reviewing guidelines; 3) Gathering first impressions of the paper followed by specific tips for reviewing; 4) the abstract and introduction; 5) Materials, methods, and results (including statistical considerations); and 6) discussion, conclusion, and references. Tip 7 concerns writing and structuring the review; Tips 7 and 8 describe how to provide constructive criticism and understanding the limits of your expertise. Finally, Tip 10 details why-and how-you become a peer reviewer. Peer review can be done by any plastic surgeon, not just those interested in an academic career. These ten tips provide useful insights for both the aspiring and the experienced peer reviewer. In conclusion, a systematic approach to peer reviewing is possible and recommended, and can help you getting started to provide quality peer reviews that contribute to moving the field of plastic surgery forward.

14.
J Int Adv Otol ; 18(3): 219-224, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35608490

RESUMO

BACKGROUND: Cochlear implantation requires excellent surgical skills; virtual reality simulation training is an effective method for acquiring basic competency in temporal bone surgery before progression to cadaver dissection. However, cochlear implantation virtual reality simulation training remains largely unexplored and only one simulator currently supports the training of the cochlear implantation electrode insertion. Here, we aim to evaluate the effect of cochlear implantation virtual reality simulation training on subsequent cadaver dissection performance and self-directedness. METHODS: This was a randomized, controlled trial. Eighteen otolaryngology residents were randomized to either mastoidectomy including cochlear implantation virtual reality simulation training (intervention) or mastoidectomy virtual reality simulation training alone (controls) before cadaver cochlear implantation surgery. Surgical performance was evaluated by two blinded expert raters using a validated, structured assess- ment tool. The need for supervision (reflecting self-directedness) was assessed via post-dissection questionnaires. RESULTS: The intervention group achieved a mean score of 22.9 points of a maximum of 44 points, which was 5.4% higher than the control group's 21.8 points (P = .51). On average, the intervention group required assistance 1.3 times during cadaver drilling; this was 41% more frequent in the control group who received assistance 1.9 times (P = .21). CONCLUSION: Cochlear implantation virtual reality simulation training is feasible in the context of a cadaver dissection course. The addition of cochlear implantation virtual reality training to basic mastoidectomy virtual reality simulation training did not lead to a significant improvement of performance or self-directedness in this study. Our findings suggest that learning an advanced temporal bone procedure such as cochlear implantation surgery requires much more training than learning mastoidectomy.


Assuntos
Implante Coclear , Implantes Cocleares , Treinamento por Simulação , Realidade Virtual , Cadáver , Competência Clínica , Humanos , Estudos Prospectivos , Treinamento por Simulação/métodos
15.
Cochlear Implants Int ; 23(2): 80-86, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34852727

RESUMO

In cochlear implantation (CI), excellent surgical technique is critical for hearing outcomes. Recent advances in temporal bone Virtual Reality (VR) training allow for specific training of CI and through introduction of new digital microscopes with ultra-high-fidelity (UHF) graphics. This study aims to investigate whether UHF increases performance in VR simulation training of CI electrode insertion compared with conventional, screen-based VR (cVR). METHODS: Twenty-four medical students completed a randomized, controlled trial of an educational intervention. They performed a total of eight CI electrode insertions each in blocks of four using either UHF-VR or cVR, in randomized order. CI electrode insertion performances were rated by two blinded expert raters using a structured assessment tool supported by validity evidence. RESULTS: Performance scores in cVR were higher than in the UHF-VR simulation although this was not significant (19.8 points, 95% CI [19.3-20.3] vs. 18.8 points, 95% CI [18.2-19.4]; P = 0.09). The decisive factor for performance was participants' ability to achieve stereovision (mean difference = 1.1 points, 95% CI [0.15-2.08], P = 0.02). DISCUSSION: No additional benefit was found from UHF-VR over cVR training of CI electrode insertion for novices. Consequently, standard cVR simulation should be used for novices' basic skills acquisition in CI surgery. Future studies should instead explore the effects of other improvements in CI surgery training and if the lacking benefit of UHF-VR also applies for more experienced learners. CONCLUSION: The increased graphical perception and the superior lifelikeness of UHF-VR does not improve early skills acquisition of CI insertion for novices.


Assuntos
Implante Coclear , Treinamento por Simulação , Realidade Virtual , Competência Clínica , Simulação por Computador , Humanos , Treinamento por Simulação/métodos
16.
Otol Neurotol ; 43(8): 900-907, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35941694

RESUMO

OBJECTIVE: Virtual reality (VR) simulation-based training effectively improves novices' mastoidectomy skills. Unfortunately, learning plateaus at an insufficient level and knowledge on optimizing mastoidectomy training to overcome this plateau is needed. In this study, we aim to investigate how training on anatomically different temporal bone cases affects learning, including the effect on retention and transfer of skills. STUDY DESIGN: Randomized controlled trial of an educational intervention. SETTING: The Simulation Center at Copenhagen Academy for Medical Education and Simulation. PARTICIPANTS: Twenty-four medical students from the University of Copenhagen. INTERVENTION: Participants were randomized to practice mastoidectomy on either 12 anatomically varying (intervention group) or 12 identical (control group) cases in a VR simulator. At the end of training and again ~ 3 weeks after training (retention), learners were tested on a new VR patient case and a three-dimensional printed model. MAIN OUTCOME MEASURE: Mastoidectomy performance evaluated by blinded expert raters using a 26-item modified Welling Scale. RESULTS: The intervention and control groups' performance results were comparable at the end of training. Likewise, retention and transfer performances were similar between groups. The overall mean score at the end of training corresponded to approximately 70% of the possible maximum score. CONCLUSIONS: Simulation-based training using anatomical variation was equivalent to training on a single case with respect to acquisition, retention, and transfer of mastoidectomy skills. This suggests that efforts to expose novices to variation during initial training are unnecessary as this variation has limited effect, and-conversely-that educators can expose novices to naturally different anatomical variations without worry of hindered learning.


Assuntos
Otolaringologia , Treinamento por Simulação , Realidade Virtual , Competência Clínica , Simulação por Computador , Humanos , Processo Mastoide/cirurgia , Mastoidectomia/educação , Otolaringologia/educação , Treinamento por Simulação/métodos
17.
Int J Pediatr Otorhinolaryngol ; 154: 111044, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35091201

RESUMO

BACKGROUND: Hearing loss (HL) in childhood is a significant disability with severe consequences for educational, cognitive, and social-emotional success. Nevertheless, prevalence estimates for HL in Sub-Saharan Africa (SSA) are based on scarce data. Therefore, we aimed to estimate the prevalence of HL in a sample of primary school children from a rural province of Zimbabwe. METHODS: A cross-sectional study was performed on primary school children aged 4-13 years from a rural Zimbabwean province. In the quietest room available, participants underwent audiometry, video otoscopy, and tympanometry. Hearing loss was defined as a pure-tone average > 25 dB. Risk factors of hearing loss were evaluated via a questionnaire. Furthermore, to enable comparison with similar studies, HL prevalence was calculated according to two other commonly used definitions. RESULTS: A total of 451 pupils were included, of which 10.6% (95% CI 7.8-13.5) met the study criteria for HL. Conductive HL (95.1%) was nineteen times more prevalent than sensorineural HL (4.9%). Otitis media was the underlying cause in 40% of all cases of HL. The prevalence of clinically significant HL varied depending on the definition applied, i.e., 0.4% (95% CI -0.2-1.0) in the worst World Health Organisation category as opposed to 4.2% (95% CI 2.4-4.1) in the worst American Speech-Hearing Association category. CONCLUSIONS: Hearing loss was common in this sample of primary school children from a rural province in Zimbabwe.


Assuntos
Perda Auditiva , Testes de Impedância Acústica , Adolescente , Audiometria de Tons Puros , Criança , Pré-Escolar , Estudos Transversais , Perda Auditiva/diagnóstico , Perda Auditiva/epidemiologia , Perda Auditiva/etiologia , Humanos , Prevalência , Zimbábue/epidemiologia
18.
Cochlear Implants Int ; 22(6): 330-337, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34151753

RESUMO

OBJECTIVE: Mastering Cochlear Implant (CI) surgery requires repeated practice, preferably initiated in a safe - i.e. simulated - environment. Mastoidectomy Virtual Reality (VR) simulation-based training (SBT) is effective, but SBT of CI surgery largely uninvestigated. The learning curve is imperative for understanding surgical skills acquisition and developing competency-based training. Here, we explore learning curves in VR SBT of CI surgery and transfer of skills to a 3D-printed model. METHODS: Prospective, single-arm trial. Twenty-four novice medical students completed a pre-training CI inserting test on a commercially available pre-drilled 3D-printed temporal bone. A training program of 18 VR simulation CI procedures was completed in the Visual Ear Simulator over four sessions. Finally, a post-training test similar to the pre-training test was completed. Two blinded experts rated performances using the validated Cochlear Implant Surgery Assessment Tool (CISAT). Performance scores were analyzed using linear mixed models. RESULTS: Learning curves were highly individual with primary performance improvement initially, and small but steady improvements throughout the 18 procedures. CI VR simulation performance improved 33% (p < 0.001). Insertion performance on a 3D-printed temporal bone improved 21% (p < 0.001), demonstrating skills transfer. DISCUSSION: VR SBT of CI surgery improves novices' performance. It is useful for introducing the procedure and acquiring basic skills. CI surgery training should pivot on objective performance assessment for reaching pre-defined competency before cadaver - or real-life surgery. Simulation-based training provides a structured and safe learning environment for initial training. CONCLUSION: CI surgery skills improve from VR SBT, which can be used to learn the fundamentals of CI surgery.


Assuntos
Implante Coclear , Implantes Cocleares , Treinamento por Simulação , Realidade Virtual , Competência Clínica , Humanos , Curva de Aprendizado , Impressão Tridimensional , Estudos Prospectivos , Osso Temporal/cirurgia
19.
Otolaryngol Head Neck Surg ; 165(5): 617-625, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33650897

RESUMO

OBJECTIVE: 3D-printed models hold great potential for temporal bone surgical training as a supplement to cadaveric dissection. Nevertheless, critical knowledge on manufacturing remains scattered, and little is known about whether use of these models improves surgical performance. This systematic review aims to explore (1) methods used for manufacturing and (2) how educational evidence supports using 3D-printed temporal bone models. DATA SOURCES: PubMed, Embase, the Cochrane Library, and Web of Science. REVIEW METHODS: Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, relevant studies were identified and data on manufacturing and validation and/or training extracted by 2 reviewers. Quality assessment was performed using the Medical Education Research Study Quality Instrument tool; educational outcomes were determined according to Kirkpatrick's model. RESULTS: The search yielded 595 studies; 36 studies were found eligible and included for analysis. The described 3D-printed models were based on computed tomography scans from patients or cadavers. Processing included manual segmentation of key structures such as the facial nerve; postprocessing, for example, consisted of removal of print material inside the model. Overall, educational quality was low, and most studies evaluated their models using only expert and/or trainee opinion (ie, Kirkpatrick level 1). Most studies reported positive attitudes toward the models and their potential for training. CONCLUSION: Manufacturing and use of 3D-printed temporal bones for surgical training are widely reported in the literature. However, evidence to support their use and knowledge about both manufacturing and the effects on subsequent surgical performance are currently lacking. Therefore, stronger educational evidence and manufacturing knowhow are needed for widespread implementation of 3D-printed temporal bones in surgical curricula.


Assuntos
Otolaringologia/educação , Modelagem Computacional Específica para o Paciente , Impressão Tridimensional , Cadáver , Humanos , Osso Temporal/cirurgia
20.
OTO Open ; 5(4): 2473974X211065012, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34926973

RESUMO

OBJECTIVE: Mastoidectomy is a cornerstone in the surgical management of middle and inner ear diseases. Unfortunately, training is challenged by insufficient access to human cadavers. Three-dimensional (3D) printing of temporal bones could alleviate this problem, but evidence on their educational effectiveness is lacking. It is largely unknown whether training on 3D-printed temporal bones improves mastoidectomy performance, including on cadavers, and how this training compares with virtual reality (VR) simulation. To address this knowledge gap, this study investigated whether training on 3D-printed temporal bones improves cadaveric dissection performance, and it compared this training with the already-established VR simulation. STUDY DESIGN: Prospective cohort study of an educational intervention. SETTING: Tertiary university hospital, cadaver dissection laboratory, and simulation center in Copenhagen, Denmark. METHODS: Eighteen otorhinolaryngology residents (intervention) attending the national temporal bone dissection course received 3 hours of mastoidectomy training on 3D-printed temporal bones. Posttraining cadaver mastoidectomy performances were rated by 3 experts using a validated assessment tool and compared with those of 66 previous course participants (control) who had received time-equivalent VR training prior to dissection. RESULTS: The intervention cohort outperformed the controls during cadaver dissection by 29% (P < .001); their performances were largely similar across training modalities but remained at a modest level (~50% of the maximum score). CONCLUSION: Mastoidectomy skills improved from training on 3D-printed temporal bone and seemingly more so than on time-equivalent VR simulation. Importantly, these skills transferred to cadaveric dissection. Training on 3D-printed temporal bones can effectively supplement cadaver training when learning mastoidectomy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA