Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 47(1): 167-171, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38041413

RESUMO

BACKGROUND: Atrial esophageal fistula (AEF) is a lethal complication that can occur post atrial fibrillation (AF) ablation. Esophageal injury (EI) is likely to be the initial lesion leading to AEF. Endoscopic examination is the gold standard for a diagnosis of EI but extensive endoscopic screening is invasive and costly. This study was conducted to determine whether fecal calprotectin (Fcal), a marker of inflammation throughout the intestinal tract, may be associated with the existence of esophageal injury. METHODS: This diagnostic study was conducted in a cohort of 166 patients with symptomatic AF undergoing radiofrequency catheter ablation from May 2020 to June 2021. Fcal tests were performed 1-7 days after ablation. All patients underwent endoscopic ultrasonography 1 or 2 days after ablation. RESULTS: The levels of Fcal were significantly different between the EI and non-EI groups (404.9 µg/g (IQR 129.6-723.6) vs. 40.4 µg/g (IQR 15.0-246.2), p < .001). Analysis of ROC curves revealed that a Fcal level of 125 µg/g might be the optimal cut-off value for a diagnosis of EI, giving a 78.8% sensitivity and a 65.4% specificity. The negative predictive value of Fcal was 100% for ulcerated EI. CONCLUSIONS: The level of Fcal is associated with EI post AF catheter ablation. 125 µg/g might be the optimal cut-off value for a diagnosis of EI. Negative Fcal could predict the absence of ulcerated EI, which could be considered a precursor to AEF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fístula Esofágica , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Complexo Antígeno L1 Leucocitário , Átrios do Coração , Fístula Esofágica/etiologia , Ablação por Cateter/efeitos adversos
2.
Pacing Clin Electrophysiol ; 46(6): 548-557, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36516139

RESUMO

Permanent pacemakers are used for symptomatic bradycardia and biventricular pacing (BVP)-cardiac resynchronization therapy (BVP-CRT) is established for heart failure (HF) patients traditionally. According to guidelines, patients' selection for CRT is based on QRS duration (QRSd) and morphology by surface electrocardiogram (ECG). Cardiovascular imaging techniques evaluate cardiac structure and function as well as identify pathophysiological substrate changes including the presence of scar. Cardiovascular imaging helps by improving the selection of candidates, guiding left ventricular (LV) lead placement, and optimization devices during the follow-up. Conduction system pacing (CSP) includes His bundle pacing (HBP) and left bundle branch pacing (LBBP) which is screwed into the interventricular septum. CSP maintains and restores ventricular synchrony in patients with native narrow QRSd and left bundle branch block (LBBB), respectively. LBBP is more feasible than HBP due to a wider target area. This review highlights the role of multimodality cardiovascular imaging including fluoroscopy, echocardiography, cardiac magnetic resonance (CMR), myocardial scintigraphy, and computed tomography (CT) in the pre-procedure assessment for CSP, better selection for CSP candidates, the guidance of CSP lead implantation, and the optimization of devices programming after the procedure. We also compare the different characteristics of multimodality imaging and discuss their potential roles in future CSP implantation.


Assuntos
Fascículo Atrioventricular , Terapia de Ressincronização Cardíaca , Humanos , Estimulação Cardíaca Artificial/métodos , Sistema de Condução Cardíaco , Doença do Sistema de Condução Cardíaco , Bloqueio de Ramo/diagnóstico por imagem , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia/métodos , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
3.
Catheter Cardiovasc Interv ; 99 Suppl 1: 1440-1447, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35077596

RESUMO

OBJECTIVES: To investigate the potential predictors and clinical significance of periprocedural myocardial infarction (PMI), as defined by the latest Fourth Universal Definition of Myocardial Infarction (2018), following rotational atherectomy (RA). BACKGROUND: PMI is not uncommon in patients undergoing RA, although the predictors and prognostic impact are unknown. METHODS: Data from 229 consecutive patients who had undergone RA before drug-eluting stent (DES) implantation in a single center were analyzed. Patients' demographic information, clinical, angiographic, and procedural characteristics, and 1-year follow-up outcomes were collected retrospectively. RESULTS: The overall incidence of PMI in patients undergoing RA was 48.5%. Age (adjusted odds ratio [OR]: 1.024, 95% confidence interval [CI]: 1.001-1.047, p = 0.043) and ejection fraction (adjusted OR: 0.977, 95% CI: 0.962-0.993, p = 0.004) were independent predictors of PMI in RA, although PMI was not associated with an increased risk of major adverse cardiovascular and cerebrovascular events (MACCEs) at the 1-year follow-up in patients undergoing RA. CONCLUSION: Age and ejection fraction were independently associated with an elevated risk of PMI in patients undergoing RA. However, post-RA microinfarcts were not associated with an increased risk of MACCEs over the short-term follow-up period.


Assuntos
Aterectomia Coronária , Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Aterectomia Coronária/efeitos adversos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos/efeitos adversos , Humanos , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
4.
Pacing Clin Electrophysiol ; 44(9): 1523-1531, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34337768

RESUMO

BACKGROUND: His bundle pacing (HBP) is a physiological pacing strategy to preserve the electrical synchrony of ventricular conduction and left ventricular (LV) function. Left bundle branch pacing (LBBP) has emerged as an alternative physiological pacing technique. OBJECTIVE: To evaluate cardiac electrical and mechanical synchrony comparing LBBP and HBP in patients with permanent atrial fibrillation (AF). METHODS: Consecutive patients with symptomatic bradycardia and AF were enrolled from January to June of 2019. The cardiac electrical and mechanical synchrony in different pacing mode were evaluated at baseline and after implantation. RESULTS: Both HBP and LBBP were performed in 20 patients. LBBP significantly widened the QRS duration compared with the intrinsic conduction (113.2 ± 14.5  vs. 96.5 ± 16.2 ms; p = .01), while HBP did not (104.5 ± 22.3  vs. 96.5 ± 16.2 ms; p = .12). Both LBBP and HBP patients had similar LV myocardial strain measurements for the mechanical synchrony evaluation without significant change compared with baseline. There was no significant difference in right ventricular synchrony measurement between LBBP and HBP. Compared to HBP, LBBP had less interventricular synchrony (IMVD, 14.7 ± 9.2  vs. 3.1 ± 12.7 ms, p < .01; Ts-LV-RV, 37.9 ± 10.7  vs. 18.5 ± 10.8 ms, p < .001). CONCLUSIONS: Although LBBP's a physiological pacing mode can achieve a similar cardiac electrical and mechanical synchronization when compared to HBP, LBBP results in modest delay in RV activation, and the clinical implication remains to be studied.


Assuntos
Fibrilação Atrial/terapia , Bradicardia/terapia , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Idoso , Fibrilação Atrial/fisiopatologia , Bradicardia/fisiopatologia , Fascículo Atrioventricular/fisiopatologia , Bloqueio de Ramo/fisiopatologia , Feminino , Humanos , Masculino
5.
J Cardiovasc Electrophysiol ; 31(2): 401-409, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31828884

RESUMO

INTRODUCTION: Repeat ablation strategy for atrial fibrillation (AF) recurrence after multiple ablation procedures is known to be challenging. This study evaluated the insights of adjunctive ablation for epicardial arrhythmogenic substrates in those patients via a percutaneous epicardial approach. METHODS AND RESULTS: Thirty-five consecutive patients with AF/atrial tachycardia (AT) recurrence, who had two or more prior ablation procedures, were enrolled from September 2016 to December 2018. In addition to a standard endocardial approach, epicardial mapping and ablation were performed via a percutaneous subxiphoid access in the electrophysiology lab. Adjunctive epicardial ablations for left lateral ridge (LLR) were performed in 31 of 35 patients (88.6%) for efficient transmural lesions with pacing capture loss. Marshall Bundle (MB) potentials were documented on epicardial LLR in three patients and abolished by direct epicardial ablation. Bachmann's bundle (BB) was ablated as an epicardial conduction gap in four patients with a refractory anterior wall line. Two epicardial AT/AF triggers were detected followed by successful termination with epicardial ablation. No periprocedural complications occurred. About 23 of 35 patients (65.7%) remained free from AF/AT after 23.2 ± 9 months of the procedure. CONCLUSIONS: Patients with multiple failed prior AF procedures refractory to antiarrhythmic therapy might warrant a percutaneous epicardial mapping and ablation strategy, with adjunctive therapy for targeting LLR/MB, BB, and underlying epicardial triggers in addition to a standard endocardial approach.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Frequência Cardíaca , Pericárdio/cirurgia , Taquicardia Supraventricular/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pericárdio/fisiopatologia , Estudos Prospectivos , Recidiva , Reoperação , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
6.
Pacing Clin Electrophysiol ; 43(7): 633-639, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32419141

RESUMO

BACKGROUND: During ablation for atrial fibrillation (AF), energy delivery toward the left atrial posterior wall may cause esophageal injury (EI). Ablation index (AI) was introduced to estimate ablation lesion size, however, the impact of AI technology on the risk of EI has not been explored. METHOD: From March 2019 to December 2019, 60 patients with paroxysmal AF undergoing first-time ablation were prospectively enrolled. The first 30 consecutive patients were ablated with the AI target value of 400 (AI-400 group), and the later 30 consecutive patients were ablated with the AI target value of 350 at the posterior wall (AI-350 group). Endoscopic ultrasonography was used to evaluate EI postablation. EI was classified as a category 1 (erythema or erosion) or a category 2 (hematoma or ulceration). RESULTS: Compared with the AI-400 group (59.9 ± 8.4 years; male, 60%), the AI-350 group (59.1 ± 9.9 years; male, 50%) had a lower incidence of EI (3.3% vs 26.7%, P = .03). There was no significant difference in the percentage of first-pass PVI between the AI-400 group and the AI-350 group (left PVI: 80% vs 73.4%, P = .54; right PVI: 80% vs 60%, P = .1). Neither ablation time nor fluoroscopy time was significantly different between the AI-400 group and the AI-350 group. CONCLUSIONS: AF ablation guide by AI target value of 350 may reduce esophageal thermal injury and has a similar efficiency on the acute success rate of first-pass PVI compared with an AI target value of 400 at the posterior wall.


Assuntos
Fibrilação Atrial/cirurgia , Queimaduras/etiologia , Ablação por Cateter/efeitos adversos , Esôfago/lesões , Endossonografia , Esôfago/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
7.
N Engl J Med ; 372(13): 1204-12, 2015 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-25774645

RESUMO

BACKGROUND: Most trials comparing percutaneous coronary intervention (PCI) with coronary-artery bypass grafting (CABG) have not made use of second-generation drug-eluting stents. METHODS: We conducted a randomized noninferiority trial at 27 centers in East Asia. We planned to randomly assign 1776 patients with multivessel coronary artery disease to PCI with everolimus-eluting stents or to CABG. The primary end point was a composite of death, myocardial infarction, or target-vessel revascularization at 2 years after randomization. Event rates during longer-term follow-up were also compared between groups. RESULTS: After the enrollment of 880 patients (438 patients randomly assigned to the PCI group and 442 randomly assigned to the CABG group), the study was terminated early owing to slow enrollment. At 2 years, the primary end point had occurred in 11.0% of the patients in the PCI group and in 7.9% of those in the CABG group (absolute risk difference, 3.1 percentage points; 95% confidence interval [CI], -0.8 to 6.9; P=0.32 for noninferiority). At longer-term follow-up (median, 4.6 years), the primary end point had occurred in 15.3% of the patients in the PCI group and in 10.6% of those in the CABG group (hazard ratio, 1.47; 95% CI, 1.01 to 2.13; P=0.04). No significant differences were seen between the two groups in the occurrence of a composite safety end point of death, myocardial infarction, or stroke. However, the rates of any repeat revascularization and spontaneous myocardial infarction were significantly higher after PCI than after CABG. CONCLUSIONS: Among patients with multivessel coronary artery disease, the rate of major adverse cardiovascular events was higher among those who had undergone PCI with the use of everolimus-eluting stents than among those who had undergone CABG. (Funded by CardioVascular Research Foundation and others; BEST ClinicalTrials.gov number, NCT00997828.).


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea , Sirolimo/análogos & derivados , Idoso , Doença da Artéria Coronariana/cirurgia , Reestenose Coronária/epidemiologia , Complicações do Diabetes/terapia , Everolimo , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/prevenção & controle , Complicações Pós-Operatórias , Estudos Prospectivos , Sirolimo/administração & dosagem , Acidente Vascular Cerebral/epidemiologia
8.
Catheter Cardiovasc Interv ; 91(S1): 617-622, 2018 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-29392879

RESUMO

BACKGROUND: Tremendous efforts have been made to establish the concept of vascular restoration therapy with a fully bioresorbable scaffold for coronary artery disease. With an improved scaffold design and technologies, the novel NeoVas scaffold has shown promising clinical performance at 6 months follow-up. OBJECTIVE: The aim of this study was to investigate the 1 year clinical outcomes and multislice computed tomography (MSCT) angiographic results after implantation of the NeoVas scaffold in patients with single de novo coronary artery lesions. METHODS: The NeoVas first-in-man study was a prospective, two-center, single-arm study enrolling 31 patients who were eligible for the treatment. The composite endpoint of target lesion failure (TLF)-defined as cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularization (TLR)-was assessed. Of the 31 patients scheduled for 1 year clinical follow-up, 29 patients received MSCT examinations. RESULTS: At 1 year follow-up, there was only 1 (3.2%) TLF, attributed to 1 patient who suffered ischemia-driven TLR at 181 days postprocedure. No cardiac deaths or scaffold thrombosis were observed. MSCT analysis demonstrated excellent vessel patency, with a median in-scaffold lumen area of 10.6 mm2 (interquartile range [IQR]: 8.2-11.7 mm2 ) and a minimal lumen diameter of 2.7 mm (IQR: 2.4-3.0 mm). CONCLUSIONS: This study demonstrated the safety and efficacy of the NeoVas scaffold for patients with single de novo coronary artery lesions at 1 year of follow-up. Noninvasive MSCT data confirmed vessel patency and the maintenance of vessel dimensions following implantation of the NeoVas bioresorbable sirolimus-eluting scaffold.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Tomografia Computadorizada Multidetectores , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Idoso , Fármacos Cardiovasculares/efeitos adversos , China , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Sirolimo/efeitos adversos , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento , Ultrassonografia de Intervenção , Grau de Desobstrução Vascular
9.
Clin Exp Pharmacol Physiol ; 45(3): 303-311, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29047162

RESUMO

Baicalin, a flavonoid glycoside separated from Scutellaria baicalensis, has cardioprotection against ischaemia/reperfusion (I/R) injury. Mitochondrial aldehyde dehydrogenase 2 (ALDH2) is considered as an endogenous protective mechanism against I/R injury depending on its anti-oxidant and anti-apoptotic characteristics. The present study demonstrates whether ALDH2 contributes to the cardioprotection of baicalin against hypoxia/reoxygenation (H/R)-inudced H9c2 cardiomyocytes injury. Our results observed that H/R treatment resulted in a significant decrease in cells viability and obvious increases in caspase-3 activity and apoptosis rate in H9c2 cells, while these alterations were evidently reversed by baicalin pretreatment. Simultaneously, baicalin mitigated H/R-induced the decreases in the levels of ALDH2 mRNA and protein as well as the activity of ALDH2 in H9c2 cells. However, we found that daidzin, an ALDH2 antagonist, remarkably attenuated baicalin-elicited inhibitory action on H/R-induced the downregulation of cells viability and Bcl-2 protein expression, and the upregulations of caspase-3 activity, apoptosis rate, cytochrome c and Bax proteins expressions in H9c2 cells. In addition, baicalin reversed H/R-induced oxidative stress as evidenced by the downregulation of malondialdehyde (MAD) and 4-hydroxy aldehydes (4-HNE) levels, the inhibition of endogenous reactive oxygen species (ROS) generation, and the downregulation of superoxide dismutase (SOD) activity induced by H/R treatment, while these effects were also blocked by daidzin. Furthermore, we found that Alda-1, an ALDH2 agonist, also abolished H/R-induced cytotoxicity, apoptosis, and oxidative stress, indicating that ALDH2 mediated H/R-induced H9c2 cell injury. Overall, these results suggested that baicalin prevents H/R-induced apoptosis and oxidative stress through enhancing ALDH activity and expression in H9c2 cardiomyocytes.


Assuntos
Aldeído-Desidrogenase Mitocondrial/metabolismo , Hipóxia Celular/efeitos dos fármacos , Flavonoides/farmacologia , Miócitos Cardíacos/efeitos dos fármacos , Estresse Oxidativo/efeitos dos fármacos , Oxigênio/metabolismo , Aldeído-Desidrogenase Mitocondrial/genética , Animais , Apoptose/efeitos dos fármacos , Cardiotônicos/farmacologia , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Regulação para Baixo , Inibidores Enzimáticos/farmacologia , Regulação Enzimológica da Expressão Gênica/efeitos dos fármacos , Ratos
10.
Pacing Clin Electrophysiol ; 39(12): 1351-1358, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27723101

RESUMO

BACKGROUND: The mechanisms underlying atrial fibrillation (AF) initiation and pulmonary vein isolation (PVI) effectiveness remain unclear. Ganglionated plexus (GPs) have been implicated in AF initiation and maintenance. In this study, we evaluated the impact of GP ablation in patients with pulmonary vein (PV) firing after PVI. METHODS: Patients with drug-refractory paroxysmal AF undergoing radiofrequency catheter ablation therapy with PVI were screened. Among 840 cases over a 3.75-year period, 12 cases were identified with persistent PV firing (left = 4 and right = 8) after PVI was achieved and left atrial sinus rhythm restored. Adjacent GP ablation was performed anatomically and followed if necessary by additional PV ablation. RESULTS: In eight patients, PV firing was terminated during GP ablation outside of the circumferential ablation line. In one patient, additional PV ablation resulted in cessation of PV firing and in the remaining three patients, firing could not be terminated by GP ablation or additional PVI. CONCLUSION: GP ablation outside of wide antral circumferential line frequently results in the cessation of rapid firing from electrically isolated PVs. These observations suggest that interactions between left atrium and PV beyond electrical conduction warrant consideration in AF mechanisms.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Gânglios Autônomos/cirurgia , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Cirurgia Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Mapeamento Potencial de Superfície Corporal/métodos , Feminino , Gânglios Autônomos/diagnóstico por imagem , Sistema de Condução Cardíaco/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Resultado do Tratamento
11.
J Pharmacol Sci ; 129(4): 205-9, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26627555

RESUMO

Collagen I is the main component of extracellular matrix in cardiac fibrosis. Our previous studies have reported inhibition of farnesylpyrophosphate synthase prevents angiotensin II-induced cardiac fibrosis, while the exact molecular mechanism was still unclear. This paper was designed to investigate the effect of alendronate, a farnesylpyrophosphate synthase inhibitor, on regulating angiotensin II-induced collagen I expression in cultured cardiac fibroblasts and to explore the underlying mechanism. By measuring the mRNA and protein levels of collagen I, we found that alendronate prevented angiotensin II-induced collagen I production in a dose-dependent manner. The inhibitory effect on collagen I expression was reversed by geranylgeraniol, and mimicked by inhibitors of RhoA/Rho kinase pathway including C3 exoenzyme and GGTI-286. Thus we suggested geranylgeranylation-dependent RhoA/Rho kinase activation was involved in alendronate-mediated anti-collagen I synthetic effect. Furthermore, we accessed the activation status of RhoA in alendronate-, geranylgeraniol- and GGTI-286-treated cardiac fibroblasts and gave an indirect evidence for RhoA activation via geranylgeranylation. Then we came to the conclusion that in cardiac fibroblasts, alendronate could protect against angiotensin II-induced collagen I synthesis through inhibition of geranylgeranylation and inactivation of RhoA/Rho kinase signaling. Targeting geranylgeranylation and RhoA/Rho kinase signaling will hopefully serve as therapeutic strategies to reduce fibrosis in heart remodeling.


Assuntos
Alendronato/farmacologia , Angiotensina II/fisiologia , Colágeno Tipo I/biossíntese , Fibroblastos/metabolismo , Miocárdio/citologia , Quinases Associadas a rho/metabolismo , Quinases Associadas a rho/fisiologia , Animais , Células Cultivadas , Depressão Química , Diterpenos/farmacologia , Relação Dose-Resposta a Droga , Ativação Enzimática/efeitos dos fármacos , Fibrose/tratamento farmacológico , Masculino , Terapia de Alvo Molecular , Miocárdio/patologia , Ratos Wistar , Transdução de Sinais/efeitos dos fármacos
12.
Cell Physiol Biochem ; 33(4): 1058-74, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24732710

RESUMO

BACKGROUNDS: Autophagy is an important process in the pathogenesis of diabetes and plays a critical role in maintaining cellular homeostasis. However, the autophagic response and its mechanism in diabetic vascular endothelium remain unclear. METHODS AND RESULTS: We studied high-glucose-induced renin-angiotensin system (RAS)-mitochondrial damage and its effect on endothelial cells. With regard to therapeutics, we investigated the beneficial effect of angiotensin-converting enzyme inhibitors (ACEIs) or angiotensin II type 1 receptor blockers (ARBs) against high-glucose-induced endothelial responses. High glucose activated RAS, enhanced mitochondrial damage and increased senescence, apoptosis and autophagic-responses in endothelial cells, and these effects were mimicked by using angiotensin II (Ang). The use of an ACEI or ARB, however, inhibited the negative effects of high glucose. Direct mitochondrial injury caused by carbonyl cyanide 3-chlorophenylhydrazone (CCCP) resulted in similar negative effects of high glucose or Ang and abrogated the protective effects of an ACEI or ARB. Additionally, by impairing autophagy, high-glucose-induced senescence and apoptosis were accelerated and the ACEI- or ARB-mediated beneficial effects were abolished. Furthermore, increases in FragEL™ DNA Fragmentation (TUNEL)-positive cells, ß-galactosidase activation and the expression of autophagic biomarkers were revealed in diabetic patients and rats, and the treatment with an ACEI or ARB decreased these responses. CONCLUSIONS: These data suggest that autophagy protects against senescence and apoptosis via RAS-mitochondria in high-glucose-induced endothelial cells.


Assuntos
Apoptose/efeitos dos fármacos , Autofagia , Glucose/farmacologia , Mitocôndrias/efeitos dos fármacos , Sistema Renina-Angiotensina/efeitos dos fármacos , Angiotensina II/farmacologia , Bloqueadores do Receptor Tipo 1 de Angiotensina II/farmacologia , Inibidores da Enzima Conversora de Angiotensina/farmacologia , Animais , Senescência Celular/efeitos dos fármacos , Fragmentação do DNA/efeitos dos fármacos , Células Endoteliais/citologia , Células Endoteliais/efeitos dos fármacos , Células Endoteliais/metabolismo , Células Endoteliais da Veia Umbilical Humana , Humanos , Hidrazonas/farmacologia , Potencial da Membrana Mitocondrial/efeitos dos fármacos , Mitocôndrias/metabolismo , Ratos , Ratos Sprague-Dawley , Receptor Tipo 1 de Angiotensina/metabolismo , beta-Galactosidase/metabolismo
13.
J Cardiovasc Electrophysiol ; 25(2): 111-8, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24118531

RESUMO

INTRODUCTION: Rapid firing in pulmonary veins (PVs) is a leading cause of paroxysmal atrial fibrillation. We hypothesized that PV firing (PV-F) should continue after circumferential PV isolation (CPVI) because the PV tissue responsible for PV-F remains intact. METHODS AND RESULTS: In Group-1 (n = 92), isoproterenol (ISP) and adenosine triphosphate (ATP) were co-administered to provoke PV-F before and after CPVI. The site of rapid focal discharge that initiated atrial fibrillation (AF) defined PV-F versus non-PV-F. Additional 17 patients with PV-F induced by ISP+ATP before CPVI were enrolled into Group-2 and various pacing maneuvers were used in conjunction to ISP+ATP to provoke PV-F after CPVI. In Group-1, AF was induced in 47/81 (58.0%) and 16/88 (18.2%) patients before and after CPVI, respectively (P < 0.01). Before CPVI, 43/47 (91.5%) of the rapid firing originated from PV. After successful CPVI, 88/92 patients were in sinus rhythm and non-PV-F was induced in 14/88 patients. PV-F was induced in 2/88 patients, which was eliminated by ganglionated plexus ablation outside the CPVI line. In Group-2, various pacing maneuvers with ISP+ATP only induced PV-F in 1/17 patients after CPVI. CONCLUSION: Marked suppression of PV-F after CPVI strongly suggests that the real source of PV-F is located in the atrium. PV-F may be an epiphenomenon.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/fisiopatologia , Potenciais de Ação , Feminino , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
14.
Adv Sci (Weinh) ; 11(23): e2401301, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38544484

RESUMO

The left atrial appendage (LAA) occluder is an important medical device for closing the LAA and preventing stroke. The device-related thrombus (DRT) prevents the implantation of the occluder in exerting the desired therapeutic effect, which is primarily caused by the delayed endothelialization of the occluder. Functional coatings are an effective strategy for accelerating the endothelialization of occluders. However, the occluder surface area is particularly large and structurally complex, and the device is subjected to a large shear friction in the sheath during implantation, which poses a significant challenge to the coating. Herein, a hydrogel coating by the in situ UV-triggered polymerization of double-network polyelectrolytes is reported. The findings reveal that the double network and electrostatic interactions between the networks resulted in excellent mechanical properties of the hydrogel coating. The sulfonate and Arg-Gly-Asp (RGD) groups in the coating promoted hemocompatibility and endothelial growth of the occluder, respectively. The coating significantly accelerated the endothelialization of the LAA occluder in a canine model is further demonstrated. This study has potential clinical benefits in reducing both the incidence of DRT and the postoperative anticoagulant course for LAA closure.


Assuntos
Hidrogéis , Polieletrólitos , Animais , Hidrogéis/química , Polieletrólitos/química , Cães , Apêndice Atrial/cirurgia , Raios Ultravioleta , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia
15.
Biomaterials ; 296: 122069, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36893653

RESUMO

The valid management of inflammation and precise inhibition of smooth muscle cells (SMCs) is regarded as a promising strategy for regulating vascular responses after stent implantation, yet posing huge challenges to current coating constructions. Herein, we proposed a spongy cardiovascular stent for the protective delivery of 4-octyl itaconate (OI) based on a "spongy skin" approach, and revealed the dual-regulation effects of OI for improving vascular remolding. We first constructed a "spongy skin" onto poly-l-lactic acid (PLLA) substrates, and realized the protective loading of OI with the highest dosage of 47.9 µg/cm2. Then, we verified the remarkable inflammation mediation of OI, and surprisingly revealed that the OI incorporation specifically inhibited SMC proliferation and phenotype switching, which contributed to the competitive growth of endothelial cells (EC/SMC ratio âˆ¼ 5.1). We further demonstrated that OI at a concentration of 25 µg/mL showed significant suppression of the TGF-ß/Smad pathway of SMCs, leading to the promotion of contractile phenotype and reduction of extracellular matrix. In vivo evaluation indicated that the successful delivery of OI fulfilled the inflammation regulation and SMCs inhibition, therefore suppressing the in-stent restenosis. This "spongy skin" based OI eluting system may serve as a new strategy for improving vascular remolding, and provides a potential concept for the treatment of cardiovascular diseases.


Assuntos
Reestenose Coronária , Humanos , Reestenose Coronária/prevenção & controle , Células Endoteliais/metabolismo , Stents , Inflamação/metabolismo
16.
Biomed Environ Sci ; 36(4): 324-333, 2023 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-37105907

RESUMO

Objective: Foreign studies have reported that coronary artery disease (CAD) patients with high baseline low-density lipoprotein cholesterol (LDL-C) may have a good prognosis, which is called the "cholesterol paradox". This study aimed to examine whether the "cholesterol paradox" also exists in the Chinese population. Methods: A total of 2,056 patients who underwent the first percutaneous coronary intervention (PCI) between 2014 and 2016 were enrolled in this retrospective cohort study and classified into two groups based on baseline LDL-C = 2.6 mmol/L (100 mg/dL). The outcomes of interest included major adverse cardiovascular events (MACE), all-cause mortality, recurrent nonfatal myocardial infarction, unexpected coronary revascularization, or any nonfatal stroke. Results: All-cause mortality occurred in 8 patients (0.7%) from the low-LDL-C group and 12 patients (2.4%) in the high-LDL-C group, with a significant difference between the two groups (adjusted hazard ratio: 4.030, 95% confidence interval: 1.088-14.934; P = 0.037). However, no significant differences existed for the risk of MACE or other secondary endpoints, such as unexpected revascularization, nor any nonfatal stroke in the two groups. Conclusion: In this study, a high baseline LDL-C was not associated with a low risk of clinical outcomes in CAD patients undergoing first PCI, which suggested that the "cholesterol paradox" may be inapplicable to Chinese populations.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Acidente Vascular Cerebral , Humanos , LDL-Colesterol , Estudos Retrospectivos , Intervenção Coronária Percutânea/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Colesterol , HDL-Colesterol , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento , Fatores de Risco
17.
J Mater Chem B ; 11(22): 4882-4889, 2023 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-37222145

RESUMO

Drug-coated balloon (DCB) is a therapeutic method that can effectively deliver antiproliferative drugs such as paclitaxel and rapamycin (RAPA) with no permanent implants left behind. However, delayed reendothelialization due to the toxicity of the delivered drugs leads to poor therapeutic effects. Here, we propose a new design of DCB coating, which incorporates both vascular endothelial growth factor (VEGF)-encoding plasmid DNA (pDNA) that can promote endothelial repair and RAPA into protamine sulfate (PrS). We demonstrate that the PrS/pDNA/RAPA coating had stability and good anticoagulation properties in vitro. We further show that the coating exhibited excellent transfer capacity from balloon substrates to vessel walls both in vitro and in vivo. Furthermore, the PrS/pDNA/RAPA coating effectively inhibited neointimal hyperplasia after balloon-induced vascular injuries through the down-regulation of the mammalian target of Rapamycin (mTOR) and promoted endothelium regeneration through increased expression of VEGF in vivo. These data indicate that our nanocomposite coating has great potential for use as a novel coating of DCB to treat neointimal hyperplasia after vascular injuries.


Assuntos
Fator A de Crescimento do Endotélio Vascular , Lesões do Sistema Vascular , Humanos , Sirolimo/farmacologia , Hiperplasia/tratamento farmacológico , Plasmídeos , DNA , Fatores de Crescimento do Endotélio Vascular
18.
J Geriatr Cardiol ; 20(4): 256-267, 2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37122993

RESUMO

OBJECTIVE: To evaluate the feasibility and tolerability of metoprolol standard dosing pathway (MSDP) in Chinese patients with acute coronary syndrome (ACS). METHODS: In this multicenter, prospective, open label, single-arm and interventional study that was conducted from February 2018 to April 2019 in fifteen Chinese hospitals. A total of 998 hospitalized patients aged ≥ 18 years and diagnosed with ACS were included. The MSDP was applied to all eligible ACS patients based on the standard treatment recommended by international guidelines. The primary endpoint was the percentage of patients achieving the target dose at discharge (V2). The secondary endpoints included the heart rate and blood pressure at V2 and four weeks after discharge (V4), and percentage of patients experiencing bradycardia (heart rate < 50 beats/min), hypotension (blood pressure < 90/60 mmHg) and transient cardiac dysfunction at V2 and V4. RESULTS: Of the 998 patients, 29.46% of patients achieved the target dose (≥ 95 mg/d) at V2. The total population was divided into two groups: target group (patients achieving the target dose at V2) and non-target group (patients not achieving the target dose at V2). There was significant difference in the reduction of heart rate from baseline to discharge in the two groups (-4.97 ± 11.90 beats/min vs. -2.70 ± 9.47 beats/min, P = 0.034). There was no significant difference in the proportion of bradycardia that occurred in the two groups at V2 (0 vs. 0, P = 1.000) and V4 (0.81% vs. 0.33%, P = 0.715). There was no significant difference in the proportion of hypotension between the two groups at V2 (0.004% vs. 0.004%, P = 1.000) and V4 (0 vs. 0.005%, P = 0.560). No transient cardiac dysfunction occurred in two groups during the study. A total of five adverse events (1.70%) and one serious adverse event (0.34%) were related to the pathway in target group. CONCLUSIONS: In Chinese ACS patients, the feasibility and tolerability of the MSDP have been proved to be acceptable.

19.
J Geriatr Cardiol ; 20(1): 51-60, 2023 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-36875168

RESUMO

BACKGROUND: His bundle pacing (HBP) and left bundle branch pacing (LBBP) both provide physiologic pacing which maintain left ventricular synchrony. They both improve heart failure (HF) symptoms in atrial fibrillation (AF) patients. We aimed to assess the intra-patient comparison of ventricular function and remodeling as well as leads parameters corresponding to two pacing modalities in AF patients referred for pacing in intermediate term. METHODS: Uncontrolled tachycardia AF patients with both leads implantation successfully were randomized to either modality. Echocardiographic measurements, New York Heart Association (NYHA) classification, quality-of-life assessments and leads parameters were obtained at baseline and at each 6-month follow up. Left ventricular function including the left ventricular endo-systolic volume (LVESV), left ventricular ejection fraction (LVEF) and right ventricular (RV) function quantified by tricuspid annular plane systolic excursion (TAPSE) were all assessed. RESULTS: Consecutively twenty-eight patients implanted with both HBP and LBBP leads successfully were enrolled (69.1 ± 8.1 years, 53.6% male, LVEF 59.2% ± 13.7%). The LVESV was improved by both pacing modalities in all patients (n = 23) and the LVEF was improved in patients with baseline LVEF at less than 50% (n = 6). The TAPSE was improved by HBP but not LBBP (n = 23). CONCLUSION: In this crossover comparison between HBP and LBBP, LBBP was found to have an equivalent effect on LV function and remodeling but better and more stable parameters in AF patients with uncontrolled ventricular rates referred for atrioventricular node (AVN) ablation. HBP could be preferred in patients with reduced TAPSE at baseline rather than LBBP.

20.
Zhejiang Da Xue Xue Bao Yi Xue Ban ; 41(6): 672-6, 2012 11.
Artigo em Zh | MEDLINE | ID: mdl-23239660

RESUMO

OBJECTIVE: To investigate the safety, medium-term and long-term efficacy of transradial percutaneous coronary intervention for unprotected left main coronary artery lesions with 6 French guiding catheter. METHODS: Sixty-one patients with unprotected left main coronary artery lesions were treated by 6 French transradial percutaneous coronary intervention between January 2008 and December 2009. The mean age of patients was (66.03 ±10.02)years (44-87). Among 61 cases, 40 had hypertension and 14 had diabetes mellitus; 22 had a history of smoking. The average left ventricle ejection fraction was (62.96 ±12.15)% (range: 28-86) and the average plasma creatinine level was (82.92 ±18.30)µmol/L (range: 44-130). The major adverse cardiac events (MACE) after the procedure were evaluated. RESULTS: Procedural success was achieved in all cases. A total of 67 stents were implanted. No in-hospital death occurred. Mean clinical follow-up period was (26.25 ±5.92) months (range: 19-44 months). MACE developed in 6 cases (9.8%) during the follow-up period, including 2 death (3.3%) and 4 case of target lesion revascularization (6.6%). Compared with low-risk group (SYNTAX score<33), MACE was increased in the high-risk group (SYNTAX score>32). CONCLUSION: 6 French transradial percutaneous coronary intervention for patients with unprotected left main coronary artery lesions is safe and feasible procedure with desirable medium-and long-term outcomes.


Assuntos
Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea/métodos , Artéria Radial , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA