Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Med Internet Res ; 26: e46857, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38289669

RESUMO

BACKGROUND: Decision support systems (DSSs) for suggesting optimal treatments for individual patients with low back pain (LBP) are currently insufficiently accurate for clinical application. Most of the input provided to train these systems is based on patient-reported outcome measures. However, with the appearance of electronic health records (EHRs), additional qualitative data on reasons for referrals and patients' goals become available for DSSs. Currently, no decision support tools cover a wide range of biopsychosocial factors, including referral letter information to help clinicians triage patients to the optimal LBP treatment. OBJECTIVE: The objective of this study was to investigate the added value of including qualitative data from EHRs and referral letters to the accuracy of a quantitative DSS for patients with LBP. METHODS: A retrospective study was conducted in a clinical cohort of Dutch patients with LBP. Patients filled out a baseline questionnaire about demographics, pain, disability, work status, quality of life, medication, psychosocial functioning, comorbidity, history, and duration of pain. Referral reasons and patient requests for help (patient goals) were extracted via natural language processing (NLP) and enriched in the data set. For decision support, these data were considered independent factors for triage to neurosurgery, anesthesiology, rehabilitation, or minimal intervention. Support vector machine, k-nearest neighbor, and multilayer perceptron models were trained for 2 conditions: with and without consideration of the referral letter content. The models' accuracies were evaluated via F1-scores, and confusion matrices were used to predict the treatment path (out of 4 paths) with and without additional referral parameters. RESULTS: Data from 1608 patients were evaluated. The evaluation indicated that 2 referral reasons from the referral letters (for anesthesiology and rehabilitation intervention) increased the F1-score accuracy by up to 19.5% for triaging. The confusion matrices confirmed the results. CONCLUSIONS: This study indicates that data enriching by adding NLP-based extraction of the content of referral letters increases the model accuracy of DSSs in suggesting optimal treatments for individual patients with LBP. Overall model accuracies were considered low and insufficient for clinical application.


Assuntos
Dor Lombar , Humanos , Dor Lombar/diagnóstico , Dor Lombar/terapia , Estudos Retrospectivos , Processamento de Linguagem Natural , Qualidade de Vida , Triagem , Aprendizado de Máquina
2.
Sensors (Basel) ; 24(10)2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38794026

RESUMO

Participant movement is a major source of artifacts in functional near-infrared spectroscopy (fNIRS) experiments. Mitigating the impact of motion artifacts (MAs) is crucial to estimate brain activity robustly. Here, we suggest and evaluate a novel application of the nonlinear Hammerstein-Wiener model to estimate and mitigate MAs in fNIRS signals from direct-movement recordings through IMU sensors mounted on the participant's head (head-IMU) and the fNIRS probe (probe-IMU). To this end, we analyzed the hemodynamic responses of single-channel oxyhemoglobin (HbO) and deoxyhemoglobin (HbR) signals from 17 participants who performed a hand tapping task with different levels of concurrent head movement. Additionally, the tapping task was performed without head movements to estimate the ground-truth brain activation. We compared the performance of our novel approach with the probe-IMU and head-IMU to eight established methods (PCA, tPCA, spline, spline Savitzky-Golay, wavelet, CBSI, RLOESS, and WCBSI) on four quality metrics: SNR, △AUC, RMSE, and R. Our proposed nonlinear Hammerstein-Wiener method achieved the best SNR increase (p < 0.001) among all methods. Visual inspection revealed that our approach mitigated MA contaminations that other techniques could not remove effectively. MA correction quality was comparable with head- and probe-IMUs.


Assuntos
Artefatos , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Masculino , Adulto , Feminino , Movimento/fisiologia , Movimento (Física) , Oxiemoglobinas/análise , Encéfalo/fisiologia , Adulto Jovem , Hemoglobinas/análise , Algoritmos , Processamento de Sinais Assistido por Computador , Hemodinâmica/fisiologia
3.
Mov Disord ; 38(7): 1327-1335, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37166278

RESUMO

BACKGROUND: Video-based tic detection and scoring is useful to independently and objectively assess tic frequency and severity in patients with Tourette syndrome. In trained raters, interrater reliability is good. However, video ratings are time-consuming and cumbersome, particularly in large-scale studies. Therefore, we developed two machine learning (ML) algorithms for automatic tic detection. OBJECTIVE: The aim of this study was to evaluate the performances of state-of-the-art ML approaches for automatic video-based tic detection in patients with Tourette syndrome. METHODS: We used 64 videos of n = 35 patients with Tourette syndrome. The data of six subjects (15 videos with ratings) were used as a validation set for hyperparameter optimization. For the binary classification task to distinguish between tic and no-tic segments, we established two different supervised learning approaches. First, we manually extracted features based on landmarks, which served as input for a Random Forest classifier (Random Forest). Second, a fully automated deep learning approach was used, where regions of interest in video snippets were input to a convolutional neural network (deep neural network). RESULTS: Tic detection F1 scores (and accuracy) were 82.0% (88.4%) in the Random Forest and 79.5% (88.5%) in the deep neural network approach. CONCLUSIONS: ML algorithms for automatic tic detection based on video recordings are feasible and reliable and could thus become a valuable assessment tool, for example, for objective tic measurements in clinical trials. ML algorithms might also be useful for the differential diagnosis of tics. © 2023 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.


Assuntos
Transtornos de Tique , Tiques , Síndrome de Tourette , Humanos , Tiques/diagnóstico , Síndrome de Tourette/diagnóstico , Reprodutibilidade dos Testes , Transtornos de Tique/diagnóstico , Aprendizado de Máquina
4.
Sensors (Basel) ; 23(8)2023 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-37112320

RESUMO

Functional near-infrared spectroscopy (fNIRS) is an optical non-invasive neuroimaging technique that allows participants to move relatively freely. However, head movements frequently cause optode movements relative to the head, leading to motion artifacts (MA) in the measured signal. Here, we propose an improved algorithmic approach for MA correction that combines wavelet and correlation-based signal improvement (WCBSI). We compare its MA correction accuracy to multiple established correction approaches (spline interpolation, spline-Savitzky-Golay filter, principal component analysis, targeted principal component analysis, robust locally weighted regression smoothing filter, wavelet filter, and correlation-based signal improvement) on real data. Therefore, we measured brain activity in 20 participants performing a hand-tapping task and simultaneously moving their head to produce MAs at different levels of severity. In order to obtain a "ground truth" brain activation, we added a condition in which only the tapping task was performed. We compared the MA correction performance among the algorithms on four predefined metrics (R, RMSE, MAPE, and ΔAUC) and ranked the performances. The suggested WCBSI algorithm was the only one exceeding average performance (p < 0.001), and it had the highest probability to be the best ranked algorithm (78.8% probability). Together, our results indicate that among all algorithms tested, our suggested WCBSI approach performed consistently favorably across all measures.


Assuntos
Artefatos , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Movimento (Física) , Neuroimagem/métodos , Movimentos da Cabeça , Algoritmos
5.
Gesundheitswesen ; 85(10): 895-903, 2023 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-37253366

RESUMO

BACKGROUND: Although digital approaches for disease prevention in older people have a high potential and are being used more often, there are still inequalities in access and use. One reason could be that in technology development future users are insufficiently taken into consideration, or involved very late in the process using inappropriate methods. The aim of this work was to analyze the motivation of older people participating, and their perceptions of future participation in the research and development process of health technologies aimed at health care for older people. METHODOLOGY: Quantitative and qualitative data from one needs assessment and two evaluation studies were analyzed. The quantitative data were analyzed descriptively and the qualitative data were analyzed content-analytically with inductive-deductive category formation. RESULTS: The median age of the 103 participants (50 female) was 75 years (64-90), most of whom were interested in using technology and had prior experience of study participation. Nine categories for participation motivation were derived. A common motivation for participation was to promote and support their own health. Respondents were able to envision participation both at the beginning of the research process and at its end. In terms of technique development, different ideas were expressed, but there was a general interest in technological development. Methods that would enable exchange with others were favored most. CONCLUSIONS: Differences in motivation to participate and ideas about participation were identified. The results provide important information from the perspective of older people and complement the existing state of research.


Assuntos
Motivação , Humanos , Feminino , Idoso , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Alemanha , Pesquisa Qualitativa , Seleção de Pacientes
6.
Sensors (Basel) ; 22(3)2022 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-35161478

RESUMO

Comprehensive measurements are needed in older populations to detect physical changes, initiate prompt interventions, and prevent functional decline. While established instruments such as the Timed Up and Go (TUG) and 5 Times Chair Rise Test (5CRT) require trained clinicians to assess corresponding functional parameters, the unsupervised screening system (USS), developed in a two-stage participatory design process, has since been introduced to community-dwelling older adults. In a previous article, we investigated the USS's measurement of the TUG and 5CRT in comparison to conventional stop-watch methods and found a high sensitivity with significant correlations and coefficients ranging from 0.73 to 0.89. This article reports insights into the design process and evaluates the usability of the USS interface. Our analysis showed high acceptance with qualitative and quantitative methods. From participant discussions, suggestions for improvement and functions for further development could be derived and discussed. The evaluated prototype offers a high potential for early detection of functional limitations in elderly people and should be tested with other target groups in other locations.


Assuntos
Programas de Rastreamento , Equilíbrio Postural , Idoso , Avaliação Geriátrica , Humanos , Modalidades de Fisioterapia , Estudos de Tempo e Movimento
7.
Sensors (Basel) ; 21(4)2021 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-33672984

RESUMO

With approaches for the detection of joint positions in color images such as HRNet and OpenPose being available, consideration of corresponding approaches for depth images is limited even though depth images have several advantages over color images like robustness to light variation or color- and texture invariance. Correspondingly, we introduce High- Resolution Depth Net (HRDepthNet)-a machine learning driven approach to detect human joints (body, head, and upper and lower extremities) in purely depth images. HRDepthNet retrains the original HRNet for depth images. Therefore, a dataset is created holding depth (and RGB) images recorded with subjects conducting the timed up and go test-an established geriatric assessment. The images were manually annotated RGB images. The training and evaluation were conducted with this dataset. For accuracy evaluation, detection of body joints was evaluated via COCO's evaluation metrics and indicated that the resulting depth image-based model achieved better results than the HRNet trained and applied on corresponding RGB images. An additional evaluation of the position errors showed a median deviation of 1.619 cm (x-axis), 2.342 cm (y-axis) and 2.4 cm (z-axis).


Assuntos
Aprendizado de Máquina , Equilíbrio Postural , Idoso , Cor , Humanos , Articulações , Estudos de Tempo e Movimento
8.
Sensors (Basel) ; 21(4)2021 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-33668682

RESUMO

This article covers the suitability to measure gait-parameters via a Laser Range Scanner (LRS) that was placed below a chair during the walking phase of the Timed Up&Go Test in a cohort of 92 older adults (mean age 73.5). The results of our study demonstrated a high concordance of gait measurements using a LRS in comparison to the reference GAITRite walkway. Most of aTUG's gait parameters demonstrate a strong correlation coefficient with the GAITRite, indicating high measurement accuracy for the spatial gait parameters. Measurements of velocity had a correlation coefficient of 99%, which can be interpreted as an excellent measurement accuracy. Cadence showed a slightly lower correlation coefficient of 96%, which is still an exceptionally good result, while step length demonstrated a correlation coefficient of 98% per leg and stride length with an accuracy of 99% per leg. In addition to confirming the technical validation of the aTUG regarding its ability to measure gait parameters, we compared results from the GAITRite and the aTUG for several parameters (cadence, velocity, and step length) with results from the Berg Balance Scale (BBS) and the Activities-Specific Balance Confidence-(ABC)-Scale assessments. With confidence coefficients for BBS and velocity, cadence and step length ranging from 0.595 to 0.798 and for ABC ranging from 0.395 to 0.541, both scales demonstrated only a medium-sized correlation. Thus, we found an association of better walking ability (represented by the measured gait parameters) with better balance (BBC) and balance confidence (ABC) overall scores via linear regression. This results from the fact that the BBS incorporates both static and dynamic balance measures and thus, only partly reflects functional requirements for walking. For the ABC score, this effect was even more pronounced. As this is to our best knowledge the first evaluation of the association between gait parameters and these balance scores, we will further investigate this phenomenon and aim to integrate further measures into the aTUG to achieve an increased sensitivity for balance ability.

9.
Sensors (Basel) ; 20(10)2020 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-32429306

RESUMO

Comprehensive and repetitive assessments are needed to detect physical changes in an older population to prevent functional decline at the earliest possible stage and to initiate preventive interventions. Established instruments like the Timed "Up & Go" (TUG) Test and the Sit-to-Stand Test (SST) require a trained person (e.g., physiotherapist) to assess physical performance. More often, these tests are only applied to a selected group of persons already functionally impaired and not to those who are at potential risk of functional decline. The article introduces the Unsupervised Screening System (USS) for unsupervised self-assessments by older adults and evaluates its validity for the TUG and SST. The USS included ambient and wearable movement sensors to measure the user's test performance. Sensor datasets of the USS's light barriers and Inertial Measurement Units (IMU) were analyzed for 91 users aged 73 to 89 years compared to conventional stopwatch measurement. A significant correlation coefficient of 0.89 for the TUG test and of 0.73 for the SST were confirmed among USS's light barriers. Correspondingly, for the inertial data-based measures, a high and significant correlation of 0.78 for the TUG test and of 0.87 for SST were also found. The USS was a validated and reliable tool to assess TUG and SST.


Assuntos
Programas de Rastreamento , Movimento , Desempenho Físico Funcional , Idoso , Idoso de 80 Anos ou mais , Humanos , Reprodutibilidade dos Testes , Postura Sentada , Posição Ortostática
10.
Sensors (Basel) ; 19(6)2019 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-30917520

RESUMO

The nematode Caenorhabditis elegans (C. elegans) is often used as an alternative animal model due to several advantages such as morphological changes that can be seen directly under a microscope. Limitations of the model include the usage of expensive and cumbersome microscopes, and restrictions of the comprehensive use of C. elegans for toxicological trials. With the general applicability of the detection of C. elegans from microscope images via machine learning, as well as of smartphone-based microscopes, this article investigates the suitability of smartphone-based microscopy to detect C. elegans in a complete Petri dish. Thereby, the article introduces a smartphone-based microscope (including optics, lighting, and housing) for monitoring C. elegans and the corresponding classification via a trained Histogram of Oriented Gradients (HOG) feature-based Support Vector Machine for the automatic detection of C. elegans. Evaluation showed classification sensitivity of 0.90 and specificity of 0.85, and thereby confirms the general practicability of the chosen approach.


Assuntos
Caenorhabditis elegans/fisiologia , Aprendizado de Máquina , Microscopia , Animais , Caenorhabditis elegans/isolamento & purificação , Processamento de Imagem Assistida por Computador , Smartphone
11.
Sensors (Basel) ; 19(6)2019 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-30893819

RESUMO

An early detection of functional decline with age is important to start interventions at an early state and to prolong the functional fitness. In order to assure such an early detection, functional assessments must be conducted on a frequent and regular basis. Since the five time chair rise test (5CRT) is a well-established test in the geriatric field, this test should be supported by technology. We introduce an approach that automatically detects the execution of the chair rise test via an inertial sensor integrated into a belt. The system's suitability was evaluated via 20 subjects aged 72⁻89 years (78.2 ± 4.6 years) and was measured by a stopwatch, the inertial measurement unit (IMU), a Kinect® camera and a force plate. A Multilayer Perceptrons-based classifier detects transitions in the IMU data with an F1-Score of around 94.8%. Valid executions of the 5CRT are detected based on the correct occurrence of sequential movements via a rule-based model. The results of the automatically calculated test durations are in good agreement with the stopwatch measurements (correlation coefficient r = 0.93 (p < 0.001)). The analysis of the duration of single test cycles indicates a beginning fatigue at the end of the test. The comparison of the movement pattern within one person shows similar movement patterns, which differ only slightly in form and duration, whereby different subjects indicate variations regarding their performance strategies.

12.
Sensors (Basel) ; 18(10)2018 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-30322042

RESUMO

Since variations in common gait parameters (such as cadence, velocity and stride-length) of elderly people are a reliable indicator of functional and cognitive decline in aging and increased fall risks, such gait parameters have to be monitored continuously to enable preventive interventions as early as possible. With scanning laser rangefinders (SLR) having been shown to be suitable for standardised (frontal) gait assessments, this article introduces an unobtrusive gait monitoring (UGMO) system for lateral gait monitoring in homes for the elderly. The system has been evaluated in comparison to a GAITRite (as reference system) with 86 participants (ranging from 21 to 82 years) passing the 6-min walk test twice. Within the considered 56,351 steps within an overall 7877 walks and approximately 34 km distance travelled, it has been shown that the SLR Hokuyo UST10-LX is more sensitive than the cheaper URG-04LX version in regard to the correct (automatic) detection of lateral steps (98% compared to 77%) and walks (97% compared to 66%). Furthermore, it has been confirmed that the UGMO (with the SLR UST10-LX) can measure gait parameters such as gait velocity and stride length with sufficient sensitivity to determine age- and disease-related functional (and cognitive) decline.


Assuntos
Marcha/fisiologia , Monitorização Ambulatorial/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos , Lasers , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial/instrumentação , Processamento de Sinais Assistido por Computador , Software , Caminhada
13.
Sensors (Basel) ; 18(10)2018 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-30279374

RESUMO

One of the most common assessments for the mobility of older people is the Timed Up and Go test (TUG). Due to its sensitivity regarding the indication of Parkinson's disease (PD) or increased fall risk in elderly people, this assessment test becomes increasingly relevant, should be automated and should become applicable for unsupervised self-assessments to enable regular examinations of the functional status. With Inertial Measurement Units (IMU) being well suited for automated analyses, we evaluate an IMU-based analysis-system, which automatically detects the TUG execution via machine learning and calculates the test duration. as well as the duration of its single components. The complete TUG was classified with an accuracy of 96% via a rule-based model in a study with 157 participants aged over 70 years. A comparison between the TUG durations determined by IMU and criterion standard measurements (stopwatch and automated/ambient TUG (aTUG) system) showed significant correlations of 0.97 and 0.99, respectively. The classification of the instrumented TUG (iTUG)-components achieved accuracies over 96%, as well. Additionally, the system's suitability for self-assessments was investigated within a semi-unsupervised situation where a similar movement sequence to the TUG was executed. This preliminary analysis confirmed that the self-selected speed correlates moderately with the speed in the test situation, but differed significantly from each other.

15.
Front Neurogenom ; 4: 1201702, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38234473

RESUMO

Introduction: Against the background of demographic change and the need for enhancement techniques for an aging society, we set out to repeat a study that utilized 40-Hz transcranial alternating current stimulation (tACS) to counteract the slowdown of reaction times in a vigilance experiment but with participants aged 65 years and older. On an oscillatory level, vigilance decrement is linked to rising occipital alpha power, which has been shown to be downregulated using gamma-tACS. Method: We applied tACS on the visual cortex and compared reaction times, error rates, and alpha power of a group stimulated with 40 Hz to a sham and a 5-Hz-stimulated control group. All groups executed two 30-min-long blocks of a visual task and were stimulated according to group in the second block. We hypothesized that the expected increase in reaction times and alpha power would be reduced in the 40-Hz group compared to the control groups in the second block (INTERVENTION). Results: Statistical analysis with linear mixed models showed that reaction times increased significantly over time in the first block (BASELINE) with approximately 3 ms/min for the SHAM and 2 ms/min for the 5-Hz and 40-Hz groups, with no difference between the groups. The increase was less pronounced in the INTERVENTION block (1 ms/min for SHAM and 5-Hz groups, 3 ms/min for the 40-Hz group). Differences among groups in the INTERVENTION block were not significant if the 5-Hz or the 40-Hz group was used as the base group for the linear mixed model. Statistical analysis with a generalized linear mixed model showed that alpha power was significantly higher after the experiment (1.37 µV2) compared to before (1 µV2). No influence of stimulation (40 Hz, 5 Hz, or sham) could be detected. Discussion: Although the literature has shown that tACS offers potential for older adults, our results indicate that findings from general studies cannot simply be transferred to an old-aged group. We suggest adjusting stimulation parameters to the neurophysiological features expected in this group. Next to heterogeneity and cognitive fitness, the influence of motivation and medication should be considered.

16.
Front Public Health ; 10: 832922, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36339229

RESUMO

Almost all Western societies are facing the challenge that their population structure is changing very dynamically. Already in 2019, ten countries had a population share of at least 20 percent in the age group of 64 years and older. Today's society aims to improve population health and help older people live active and independent lives by developing, establishing, and promoting safe and effective interventions. Modern technological approaches offer tremendous opportunities but pose challenges when preventing functional decline. As part of the AEQUIPA Prevention Research Network, the use of technology to promote physical activity in older people over 65 years of age was investigated in different settings and from various interdisciplinary perspectives, including technology development and evaluation for older adults. We present our findings in three main areas: (a) design processes for developing technology interventions, (b) older adults as a user group, and (c) implications for the use of technology in interventions. We find that cross-cutting issues such as time and project management, supervision of participants, ethics, and interdisciplinary collaboration are of vital importance to the success of the work. The lessons learned are discussed based on the experiences gained in the overall AEQUIPA network while building, particularly on the experiences from the AEQUIPA sub-projects TECHNOLOGY and PROMOTE. Our experiences can help researchers of all disciplines, industries, and practices design, study and implement novel technology-based interventions for older adults to avoid pitfalls and create compelling and meaningful solutions.


Assuntos
Exercício Físico , Pesquisadores , Humanos , Idoso , Pessoa de Meia-Idade , Tecnologia
17.
Appl Ergon ; 93: 103357, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33524664

RESUMO

The Ovako Working posture Assessment System (OWAS) is a commonly used observational assessment method for determining the risk of work-related musculoskeletal disorders. OWAS claims to be suitable in the application for untrained persons but there is not enough evidence for this assumption. In this paper, inter-rater (inter-observer) reliability (agreement) is examined down to the level of individual postures and categories. For this purpose, the postures of 20 volunteers have been observed by 3 varying human raters in a laboratory setting and the inter-rater agreement against reference values was determined. A high agreement of over 98%(κ=0.98) was found for the postures of the arms but lower agreements were found for posture classification of the legs (66-97%,κ=0.85) and the upper body (80-96%,κ=0.85). No significant difference was found between raters with and without intense prior training in physical therapy. Consequently, the results confirm the general reliability of the OWAS method especially for raters with non-specialized background but suggests weaknesses in the reliable detection of a few particular postures.


Assuntos
Ergonomia , Doenças Musculoesqueléticas , Humanos , Doenças Musculoesqueléticas/etiologia , Variações Dependentes do Observador , Postura , Reprodutibilidade dos Testes
18.
Biosensors (Basel) ; 11(8)2021 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-34436059

RESUMO

Caenorhabditis elegans (C. elegans) is an important model organism for studying molecular genetics, developmental biology, neuroscience, and cell biology. Advantages of the model organism include its rapid development and aging, easy cultivation, and genetic tractability. C. elegans has been proven to be a well-suited model to study toxicity with identified toxic compounds closely matching those observed in mammals. For phenotypic screening, especially the worm number and the locomotion are of central importance. Traditional methods such as human counting or analyzing high-resolution microscope images are time-consuming and rather low throughput. The article explores the feasibility of low-cost, low-resolution do-it-yourself microscopes for image acquisition and automated evaluation by deep learning methods to reduce cost and allow high-throughput screening strategies. An image acquisition system is proposed within these constraints and used to create a large data-set of whole Petri dishes containing C. elegans. By utilizing the object detection framework Mask R-CNN, the nematodes are located, classified, and their contours predicted. The system has a precision of 0.96 and a recall of 0.956, resulting in an F1-Score of 0.958. Considering only correctly located C. elegans with an AP@0.5 IoU, the system achieved an average precision of 0.902 and a corresponding F1 Score of 0.906.


Assuntos
Caenorhabditis elegans , Microscopia , Animais , Ensaios de Triagem em Larga Escala , Humanos
19.
Assist Technol ; 32(1): 1-8, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-29482463

RESUMO

To initiate appropriate interventions and avoid physical decline, comprehensive measurements are needed to detect functional changes in elderly people at the earliest possible stage. The established Timed Up&Go (TUG) test takes little time and, due to its standardized and easy procedure, can be conducted by elderly people in their own homes without clinical guidance. Therefore, cheap light barriers (LBs) and force sensors (FSs) are well suited ambient sensors that could easily be attached to existing (arm)chairs to measure and report TUG times in order to identify functional decline. We validated the sensitivity of these sensors in a clinical trial with 100 elderlies aged 58-92 years with a mean of 74 (±6.78) years by comparing the sensor-based results with standard TUG measurements using a stopwatch. We further evaluated the accuracy enhancement when calibrating the algorithm via a mixed linear model. With calibration, the LBs achieved a root mean square error (RMSE) of 0.83 s, compared to 1.90 s without, and the FSs achieved 0.90 s compared to 2.12 s without. The suitability of measuring accurate TUG times with each of the ambient sensors and of measuring TUG regularly in the homes of elderly people could be confirmed.


Assuntos
Avaliação Geriátrica/métodos , Locomoção , Acidentes por Quedas/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Tempo de Reação/fisiologia , Reprodutibilidade dos Testes
20.
Stud Health Technol Inform ; 253: 225-229, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30147079

RESUMO

In this paper, we show how the XML dialect SKAML (Skeletal Assessment Markup Language) can be used to use data from one or more Motion Capture systems to perform human posture assessments with multiple assessment methods. We show an implementation example using an inertial measuring suit and both OWAS and REBA assessment methods. SKAML makes it possible to implement classifiers for a Motion Capture system once and adapt the classifier by-configuration to various ergonomics assessment methods. We anticipate our work as help for researchers and developers that implement new assessment methods or motion capture systems.


Assuntos
Ergonomia , Postura , Software , Humanos , Movimento (Física) , Linguagens de Programação , Estatística como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA