RESUMO
BACKGROUND AND PURPOSE: Anticoagulant therapy with vitamin K antagonists is recommended within 3 to 6 months after bioprosthetic valve replacement to prevent thromboembolic events. However, data regarding whether direct oral anticoagulants can be an alternative to warfarin in such patients are limited. The purpose of this study is to compare the efficacy and safety of edoxaban versus warfarin within 3 months after bioprosthetic valve replacement. METHODS: The ENBALV trial is an investigator-initiated, phase 3, randomized, open-label, multicenter study. It involves patients aged 18 to 85 years undergoing bioprosthetic valve replacement at the aortic and/or mitral position. They are randomized 1:1 to receive either edoxaban or warfarin. Administration of edoxaban or warfarin is to be continued for 12 weeks after surgery. The primary outcome is the occurrence rate of stroke or systemic embolism at 12 weeks after surgery. The net clinical outcome is a composite of stroke, systemic embolism, or major bleeding, which is included in the secondary outcomes. CONCLUSION: The ENBALV trial demonstrates the efficacy and safety of edoxaban compared with warfarin in patients early after bioprosthetic valve replacement, including patients with sinus rhythm, which will bring a significant benefit to patients in clinical practice. TRIAL REGISTRATION: Japan Registry of Clinical Trials (jRCT) 2051210209. 30 Mar 2022 https://jrct.niph.go.jp/latest-detail/jRCT2051210209 .
RESUMO
Since 2011, implantable ventricular assist devices have been a standard treatment for severe heart failure alongside heart transplantation in Japan. However, the limited availability of donors has led to a prolonged wait for transplants, now averaging 1719 days, intensifying the issue of aortic insufficiency in patients with continuous flow ventricular assist devices. These devices limit the opening of the aortic valve, leading to sustained closure and increased shear stress, which accelerates valve degradation. Risk factors for aortic insufficiency include having a smaller body surface area, being of advanced age, and the presence of mild aortic insufficiency prior to device implantation. In patients presenting with mild or moderate aortic regurgitation at the time of ventricular assist device implantation, interventions such as aortic valve repair or bioprosthetic valve replacement are performed with the aim of halting its progression. The choice of surgical procedure should be tailored to each patient's individual condition. The management of de novo aortic insufficiency in patients with continuous flow ventricular assist devices remains challenging, with no clear consensus on when to intervene. Interventions for significant aortic insufficiency typically consider the patient's symptoms and aortic insufficiency severity. De novo aortic insufficiency progression in continuous flow ventricular assist devices patients necessitates careful monitoring and intervention based on individual patient assessments and valve condition. This review was created based on a translation of the Japanese review written in the Japanese Journal of Artificial Organs in 2023 (Vol. 52, No. 1, pp. 77-80), with some modifications.
Assuntos
Insuficiência da Valva Aórtica , Coração Auxiliar , Humanos , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/fisiopatologia , JapãoRESUMO
The mortality rate in patients with heart failure complicated by cardiogenic shock following acute myocardial infarction (AMI) remains high, prompting research on mechanical circulatory support. Improved mortality rates have been reported with the early introduction of EcMELLA (Impella combined with extracorporeal membrane oxygenation, ECMO). However, clear indications for this treatment have not been established, given the associated risks and limitations related to access routes. Left ventricular thrombosis is traditionally considered a contraindication for Impella use. A 74-year-old man without specific medical history or coronary risk factors was diagnosed with Forrester IV heart failure due to cardiogenic shock complicated by AMI and left ventricular thrombosis. The patient underwent emergency coronary artery bypass surgery, intracardiac thrombus removal, and Dor surgery. Following cardiopulmonary bypass, ongoing heart failure was observed, necessitating the implementation of EcMELLA for circulatory support. Preoperative computed tomography showed that the bilateral subclavian arteries were too narrow (< 7 mm) and anatomically unsuitable for traditional access methods. Thus, we introduced a single-access EcMELLA 5.5, through which the Impella was introduced and veno-arterial-ECMO blood was delivered from a single artificial vessel anastomosed to the brachiocephalic artery. The patient was weaned off veno-arterial-ECMO and extubated on postoperative day 3. By postoperative day 14, improved cardiac function allowed for Impella removal. The patient was discharged on postoperative day 31 with improved ambulation; thereafter, the patient returned to work. Thus, the single-access EcMELLA5.5 treatment strategy combined with Dor procedure was effective in left ventricular thrombosis in patients with heart failure with cardiogenic shock complicated by AMI.
RESUMO
There are no criteria for surgical mechanical circulatory system (MCS) selection for acute heart failure. Since 2021, we have utilized cardiopulmonary bypass system to assess patients' heart and lung condition to inform surgical MCS selection. we aimed to retrospectively analyze the outcomes of treatments administered using our protocol. We analyzed the data of 19 patients who underwent surgical MCS implantation. We compared patients' characteristics across the biventricular-assist device (BiVAD), central Y-Y extracorporeal membrane oxygenation (ECMO), central ECMO, and left VAD (LVAD) systems. Patients' diagnoses included fulminant myocarditis (47.4%), dilated cardiomyopathy (21.1%), acute myocardial infarction (15.8%), infarction from aortic dissection (5.3%), doxorubicin-related cardiomyopathy (5.3%), and tachycardia-induced myocarditis (5.3%). Eight patients (42.1%) underwent LVAD implantation, 1 (5.2%) underwent central ECMO, 4 (21.1%) underwent BiVAD implantation, and 6 (31.6%) underwent central Y-Y ECMO. 48 h after surgery, both the pulmonary arterial and right atrial pressures were effectively controlled, with median values being 19.0 mmHg and 9.0 mmHg, respectively. No patients transitioned from LVAD to BiVAD in the delayed period. Cerebrovascular events occurred in 21.1%. Successful weaning was achieved in 11 patients (57.9%), and 5 patients (26.3%) were converted to durable LVAD. Two-year cumulative survival was 84.2%. Our protocol showed good results for device selection in patients with heart failure, and device selection according to this protocol enabled good control of the pulmonary and systemic circulations.
RESUMO
BACKGROUND: Recent studies have reported atrial involvement and coexistence of aortic stenosis in transthyretin (ATTR) cardiac amyloidosis (CA). However, pathological reports of extraventricular ATTR amyloid deposits in atrial structures or heart valves are limited, and the clinical implications of ATTR amyloid deposits outside the ventricles are not fully elucidated. CASE PRESENTATION: We report 3 cases of extraventricular ATTR amyloid deposits confirmed in surgically resected aortic valves and left atrial structures, all of which were unlikely to have significant ATTR amyloidosis infiltrating the ventricles as determined by multimodality evaluation including 99mtechnetium-pyrophosphate scintigraphy, cardiac magnetic resonance, endomyocardial biopsy and their mid-term clinical course up to 5 years. These findings suggested that these were extraventricular ATTR amyloid deposits localized in the aortic valve and the left atrium. CONCLUSIONS: While long-term observation is required to fully clarify whether these extraventricular ATTR amyloid deposits are truly localized outside the ventricles or are early stages of ATTR-CA infiltrating the ventricles, our 3 cases with multimodality evaluations and mid-term follow up suggest the existence of extraventricular ATTR amyloid deposits localized in the aortic valve and left atrial structures.
Assuntos
Neuropatias Amiloides Familiares , Fibrilação Atrial , Cardiomiopatias , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Neuropatias Amiloides Familiares/diagnóstico por imagem , Seguimentos , Placa Amiloide , Pré-Albumina/genética , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Cardiomiopatias/diagnóstico por imagemRESUMO
BACKGROUND: Pulmonary complications often occur in patients receiving veno-arterial extracorporeal membrane oxygenation (VA ECMO). However, the prognostic impact of lung damage has not been fully elucidated. METHODS: This single-center retrospective observational study targeted patients with cardiogenic shock who received VA ECMO between 2012 and 2021. This study included 65 patients who underwent chest computed tomography (CT) on VA ECMO, followed by escalation to central mechanical circulatory support (MCS) with left ventricular venting. The average density of lung CT images was measured using region-of-interest methods, and the primary endpoint was 180-day all-cause death after escalation to the central MCS. RESULTS: Twenty-two patients (34%) developed 180-day all-cause death. According to the Cox regression analysis, age (hazard ratio [HR], 1.08; 95% confidence interval [CI], 1.03-1.14; p = 0.001), ischemic etiology (HR, 5.53; 95% CI, 2.09-14.62; p < 0.001), duration of VA ECMO support (HR, 1.19; 95% CI, 1.00-1.40; p = 0.045), and lung CT density (≥ -481 Hounsfield unit [HU]) (HR, 6.33; 95% CI, 2.26-17.72; p < 0.001) were independently associated with all-cause death. Receiver operating characteristic curve analysis determined that lung CT density ≥ -481 HU is an optimal cutoff value for predicting all-cause death (area under the curve [AUC], 0.72). The 180-day overall survival rate for patients with high lung CT density (≥ -481 HU) was significantly lower than that for those with low lung CT density (< -481 HU) (44.4% vs. 81.6%, respectively, p = 0.002). CONCLUSIONS: Higher lung CT density could be a useful predictor of death in patients with VA ECMO requiring central MCS escalation.
Assuntos
Oxigenação por Membrana Extracorpórea , Choque Cardiogênico , Humanos , Prognóstico , Choque Cardiogênico/diagnóstico por imagem , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Oxigenação por Membrana Extracorpórea/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Pulmão/diagnóstico por imagemRESUMO
OBJECTIVES: Placement of the Impella 5.0 percutaneous left ventricular assist device may cause aortic regurgitation (AR) due to malcoaptation of the aortic leaflets. The authors investigated the prevalence and severity of AR during Impella 5.0 support. DESIGN: Retrospective observational study. SETTING: An academic hospital. PARTICIPANTS: A total of forty-two consecutive patients who underwent Impella 5.0 implantation from April 2018 to March 2022. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: To investigate AR prevalence, the authors calculated the AR volume by subtracting left ventricular inflow from left-sided systemic flow, the latter of which consisted of flow through the Impella 5.0 cannula and across the aortic valve. Because it is challenging to estimate flow across the aortic valve as distinct from that through Impella 5.0, the authors analyzed 19 of 42 patients whose aortic valves were closed (ie, those with no spontaneous cardiac output). AR due to Impella 5.0 was considered present if the AR fraction was ≥7%. The median AR volume was 0.6 L/min (interquartile range: 0.4-1.5 L/min), which was 13.5% (interquartile range: 11.0 to 30.6%) of the median Impella 5.0 flow. Seventeen of the 19 patients (89.5%) were diagnosed with AR during Impella 5.0 support, and the severity of AR was mild in 11 patients (57.9%) and moderate in 6 (31.6%). CONCLUSIONS: The authors revealed a high prevalence of AR during Impella 5.0 support in patients with no spontaneous cardiac output. Moreover, 31.6% of patients had moderate AR.
Assuntos
Insuficiência da Valva Aórtica , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/epidemiologia , Insuficiência da Valva Aórtica/etiologia , Prevalência , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estudos Retrospectivos , Resultado do TratamentoRESUMO
Implantation of left ventricular assist device (LVAD) for arrhythmogenic right ventricular (RV) cardiomyopathy is challenging associated with small LV cavity, laterally dislocated LV apex, thin and fragile RV free wall. A 43-year-old male with more than 10 years of medical treatment developed congestive heart failure related to biventricular failure. Durable LVAD was indicated to prevent further deterioration of the RV function, which would be exacerbated by progression of LV dysfunction. To simulate surgery, we printed-out a 3D heart model based on enhanced CT scanning study to identify the optimal coring position in the LV apex, by which the inflow directs the mitral valve. We then found that the mini-cuff of the HeartMate3 should be fixed in the paper-thin RV free wall by the usual cuff-sewing method. In the surgery, after the coring as planned, 5 pairs of interrupted sutures on the medial side were passed from the luminal side of the LV and then to the mini-cuff, and the lateral side of the mini-cuff was fixed with a continuous sutures, not to sew into the RV wall. The surgery was completed without complications with a good hemodynamics. The 3D heart model facilitated this unique method, indicating a usefulness of printed-out heart model for cases with unusual cardiac anatomy, which needs implantation of durable LVAD.
Assuntos
Displasia Arritmogênica Ventricular Direita , Insuficiência Cardíaca , Coração Auxiliar , Disfunção Ventricular Esquerda , Disfunção Ventricular Direita , Masculino , Humanos , Adulto , Displasia Arritmogênica Ventricular Direita/cirurgia , Displasia Arritmogênica Ventricular Direita/complicações , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/cirurgia , Disfunção Ventricular Esquerda/complicações , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Disfunção Ventricular Direita/etiologia , Função Ventricular DireitaRESUMO
BACKGROUND: Chronic postsurgical pain (CPSP) worsens patients' mortality, morbidity, and quality of life. Cardiopulmonary bypass is mandatory for cardiac surgery, but it induces intense inflammation. The presence of inflammation is a crucial part of pain sensitization. An extreme inflammatory response due to cardiopulmonary bypass might cause a high prevalence of CPSP after cardiac surgery. We hypothesized that the prevalence and severity of CPSP are higher in patients after on-pump coronary artery bypass graft (CABG) surgery than in those after off-pump CABG surgery. METHODS: This prospective, observational study was performed on a cohort from a randomized trial (on-pump CABG: 81 patients, off-pump CABG: 86 patients). A questionnaire about the severity of surgical wound pain that evaluated pain with the numerical rating scale (NRS) was filled out by the patients. NRS responses for current pain, peak pain in the last 4 weeks, and average pain in the last 4 weeks were evaluated. The main outcomes were the severity of CPSP as evaluated using the NRS and the prevalence of CPSP. CPSP was defined as pain with an NRS score > 0. Differences in severity between groups were analyzed using multivariate ordinal logistic regression models adjusted for age and sex, and differences in prevalence between groups were analyzed using multivariate logistic regression models adjusted for age and sex. RESULTS: The questionnaire return rate was 77.0%. During a median follow-up of 17 years, 26 patients complained of CPSP (on-pump CABG: 20 patients, off-pump CABG: 6 patients). Ordinal logistic regression showed that the NRS response for current pain (odds ratio [OR] 2.34; 95% CI 1.12-4.92; P = 0.024) and the NRS response for peak pain in the last 4 weeks (OR 2.71; 95% CI 1.35-5.42; P = 0.005) were significantly higher in patients who underwent on-pump CABG surgery than in those who underwent off-pump CABG. Logistic regression showed that on-pump CABG surgery was an independent predictor of CPSP (OR 2.59; 95% CI 1.06-6.31; P = 0.036). CONCLUSIONS: The prevalence and severity of CPSP are higher in patients with on-pump CABG surgery than in those with off-pump CABG surgery.
Assuntos
Ponte Cardiopulmonar , Ponte de Artéria Coronária sem Circulação Extracorpórea , Humanos , Seguimentos , Estudos Prospectivos , Ponte Cardiopulmonar/efeitos adversos , Qualidade de Vida , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Dor Pós-Operatória/epidemiologia , Dor Pós-Operatória/etiologia , Inflamação , Resultado do TratamentoRESUMO
Patients with cirrhosis have increased mortality and complication rates with increasing severity. The hyperdynamic circulatory state is associated with vasodilatation, and drastic changes in circulatory dynamics can induce multiple organ failures, including renal failure. Intensive perioperative systemic management is essential.
Assuntos
Ponte Cardiopulmonar , Cirrose Hepática , Humanos , Ponte Cardiopulmonar/efeitos adversos , Cirrose Hepática/complicações , Cirrose Hepática/cirurgia , Insuficiência de Múltiplos Órgãos/complicaçõesRESUMO
BACKGROUND: It is unknown whether early atrial tachyarrhythmia (ATA) recurrence occurring within 3 months after the Maze procedure predicts late ATA recurrence.MethodsâandâResults: This study involved 610 patients who underwent the modified Cryo-Maze procedure in conjunction with other cardiac surgery. The primary outcomes were late ATA recurrence, defined as occurring ≥3 months after surgery. The effects of early ATA recurrence on late ATA recurrence were analyzed using a Cox proportional hazards model. The following 11 covariates were considered explanatory variables: early ATA recurrence, age, sex, body surface area, preoperative duration of atrial fibrillation, preoperative left atrial diameter, and concomitant surgery (mitral valve replacement, mitral valve repair, aortic valve replacement, tricuspid annuloplasty, and left atrial appendage closure). Statistical analyses were performed with a 2-sided 5% significance level. Early ATA recurrence occurred in 174 patients (28.5%). Late ATA recurrence occurred in 167 patients (27.5%), with 595 events identified in these patients. The Cox proportional hazards model showed that early ATA recurrence was an independent predictor of late ATA recurrence (hazard ratio, 4.14; 95% confidence interval, 3.00-5.70; P<0.001)Conclusions: Early ATA recurrence was an independent predictor of late ATA recurrence among patients undergoing the modified Cryo-Maze procedure. The blanking period might not be applied to patients undergoing the modified Cryo-Maze procedure.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Resultado do Tratamento , Procedimento do Labirinto , Átrios do Coração , Taquicardia/diagnóstico , Recidiva , Ablação por Cateter/efeitos adversosRESUMO
BACKGROUND: This study aimed to elucidate the short-term surgical outcomes and hemodynamics of the Intuity valve compared to the standard bioprosthesis in Japanese patients.MethodsâandâResults: Among the 307 consecutive patients who underwent aortic valve replacement (AVR) between February 2019 and March 2021, the Intuity valve was implanted in 95 patients (Intuity group) and a conventional stented bioprosthesis was implanted in 193 patients (conventional group). After propensity score matching, there was no significant difference in in-hospital mortality between the Intuity (n=2, 3%) and conventional groups (n=0, P=0.490). Operation, cardiopulmonary bypass, and aortic cross-clamping times were significantly shorter in the Intuity group. Although the effective orifice area index, trans-prosthetic mean pressure gradient, and peak velocity were similar between the 2 groups at 1 week postoperatively, the Intuity group showed a better mean pressure gradient and peak velocity at 1 year postoperatively. Complete atrioventricular block requiring permanent pacemaker implantation developed in 2 patients (3%) in the Intuity group and none in the conventional group (P=0.476). Mild or greater paravalvular leakage was present in 8 patients (13%) in the Intuity group and 2 patients (3%) in the conventional group (P=0.095). CONCLUSIONS: AVR using the Intuity valve in Japanese patients is satisfactory, with a better valve performance and a low incidence of complete atrioventricular block at 1 year postoperatively.
Assuntos
Estenose da Valva Aórtica , Bloqueio Atrioventricular , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Valva Aórtica/cirurgia , Japão , Desenho de Prótese , Resultado do TratamentoRESUMO
BACKGROUND: Transaortic transcatheter aortic valve replacement (TAo-TAVR) is an alternative to peripheral or transapical TAVR. The procedural feasibility, safety, and midterm outcomes of TAo-TAVR were investigated in this study.MethodsâandâResults:Eighty-four consecutive patients underwent TAo-TAVR from 2011 to 2021. Their median age was 83 years (interquartile range, 80-87 years). The Edwards SAPIEN and Medtronic CoreValve devices were used in 45 (53.6%) and 38 (45.2%) patients, respectively. The surgical approach was a right mini-thoracotomy in 43 patients (51.2%) and partial sternotomy in 4 patients (4.8%). The remaining 37 patients (44.0%) underwent full sternotomy because of concomitant off-pump coronary artery bypass grafting. VARC-3 device success was achieved in 77 patients (91.7%). Valve migration occurred in 3 patients (3.6%) using a first-generation CoreValve device, necessitating implantation of a second valve. No aortic annulus rupture, aortic dissection, or coronary orifice occlusion occurred. Conversion to surgery was required for 1 patient because of uncontrollable bleeding. Only 1 in-hospital death occurred. New pacemaker implantation was required in 6 patients (7.1%). Echocardiography at discharge showed no or trivial paravalvular leak (PVL) in 58 patients (69.0%), mild PVL in 23 (27.4%), and mild to moderate PVL in 2 (2.4%) patients. The 1- and 3-year incidence of cardiovascular death was 1.6% and 4.8%, respectively, with no structural valve deterioration. CONCLUSIONS: TAo-TAVR is feasible and safe with satisfactory midterm outcomes using both currently available devices.
Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos de Viabilidade , Mortalidade Hospitalar , Humanos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Resultado do TratamentoRESUMO
BACKGROUND: The superiority of a fully magnetically levitated centrifugal-flow left ventricular assist device (LVAD) in terms of overall survival, stroke events and pump thrombosis has been demonstrated in previous international analyses, so we evaluated a Japanese cohort for the same.MethodsâandâResults: This retrospective observational study was conducted at Osaka University Medical Hospital and the National Cerebral and Cardiovascular Center in Japan. A total of 75 consecutive patients who underwent HeartMate3 (HM3) implantation were included. The primary endpoint was on-device survival, and the secondary endpoint was the incidence of LVAD-related complications at 2 years. All parameters were compared with those of the previously performed HeartMate II (HMII) implantation in 197 cases. The on-device survival rates were 94.7% and 92.3% in the HM3 and HMII groups, respectively, at the 2-year follow-up (P=0.62). The rehospitalization-free rate after implantation was 61.8% in the HM3 group, which was significantly higher than that in the HMII group (relative risk, 0.35; 95% confidence interval [CI], 0.23-0.55; P<0.0001). Event-free survival rates from cerebral cerebrovascular events and pump thrombosis in the HM3 group were significantly higher than those in the HMII group, at 97.2% and 100%, respectively (relative risk, 0.14; 95% CI 0.03-0.58); P=0.0015 and relative risk, not calculated; P=0.049, respectively). CONCLUSIONS: Satisfactory short-term outcomes were observed after HM3 implantation in a Japanese cohort.
Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Trombose , Humanos , Coração Auxiliar/efeitos adversos , Japão/epidemiologia , Acidente Vascular Cerebral/complicações , Trombose/etiologia , Estudos Retrospectivos , Resultado do TratamentoRESUMO
A bridging strategy from extracorporeal life support (ECLS) is effective in salvage and a bridge to recovery or to a durable left ventricular assist device (LVAD) for acute refractory heart failure. However, the correlation of this strategy with adverse events after durable LVAD implantation has not been fully investigated. This study enrolled 158 consecutive patients who had either the HeartMate II or HeartMate 3 and were implanted for bridge-to-transplantation. These devices were implanted as the primary mechanical support device in 115 patients, whereas the remaining 43 underwent LVAD implantation as the bridge from central ECLS. The primary study endpoint was all-cause mortality and cerebrovascular accidents (CVAs) after durable LVAD implantation, and the secondary endpoints were adverse events. Overall survival was not significantly different between the two groups. In contrast, the probability of CVAs was significantly greater in the bridge group than in the primary group (probability of CVAs, P = 0.002; log-rank test). In Cox multivariate logistic regression analysis, a bridge from central ECLS was an independent predictive factor of CVAs (hazard ratio 4.27, 95% confidence interval 1.43-12.8; P = 0.0095). Patients who are bridged from central ECLS are more frequently complicated by CVAs compared with those who undergo primary implantation of a durable LVAD, but survival is not significantly different between the two groups. A bridge from central ECLS is an independent predictive factor of CVAs post-implantation of an LVAD.
Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Humanos , Estudos Retrospectivos , Fatores de Risco , Resultado do TratamentoRESUMO
Sleep-disordered breathing (SDB) is associated with an increased risk of adverse events in patients with heart failure (HF); however, its impact in patients implanted with a left ventricular assist device (LVAD) remains unclear. We aimed to investigate the prevalence of SDB in patients with LVAD and its impact on their clinical outcomes. Fifty consecutive patients with LVAD who underwent portable sleep monitoring between September 2017 and April 2018 were prospectively enrolled, and they were followed up for 170 ± 36 days. According to their respiratory disturbance indexes (RDIs), they were categorized into the SDB group (RDI ≥ 15, n = 12) and the non-SDB group (RDI < 15, n = 38). The incidence of adverse events during the follow-up period was investigated after enrollment. Multivariate logistic regression analysis revealed significant differences in SDB in LVAD-implanted patients in terms of the logarithmic transformation brain natriuretic peptide (BNP) values (p = 0.005). The optimal BNP cut-off value for SDB prediction in LVAD-implanted patients was 300 pg/mL (sensitivity: 58.3%, specificity: 94.7%). During follow-up, ventricular tachyarrhythmias (VTas) occurred significantly more frequently in the SDB group (4 [33%] vs. 2 [5%] patients, p = 0.02); Atrial tachyarrhythmia (ATa) also tended to occur more frequently in the SDB group (2 [25%] vs. 2 [2%] patients, p = 0.07). SBD was prevalent in 24% of the LVAD-implanted patients with advanced HF. Furthermore, SDB was significantly associated with high BNP levels and was also potentially associated with subsequent incidence of VTa in patients with LVAD.
Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Síndromes da Apneia do Sono , Taquicardia Ventricular , Humanos , IncidênciaRESUMO
AIM: This study aimed to evaluate the early and intermediate-term outcomes of patients who underwent concomitant off-pump coronary artery bypass grafting (CABG) and transcatheter aortic valve replacement (TAVR). METHOD: Between January 2014 and June 2021, 49 patients underwent concomitant off-pump CABG and TAVR via median sternotomy (TAVRCAB group) and 143 underwent concomitant on-pump CABG and surgical aortic replacement. Of the 143 patients who underwent on-pump surgery, 80 (SAVRCAB group) were eligible for comparison. The composite event included all-cause death, heart failure rehospitalisation, repeat revascularisation, brain infarction, and repeat aortic valve replacement. RESULTS: The Society of Thoracic Surgeons' predicted risk for mortality and age were higher in the TAVRCAB group than in the SAVRCAB group (7.1% vs 3.1% [p<0.001]; 81 yrs vs 75 years [p<0.001], respectively), while the surgical time was shorter (289 min vs 352 min; p<0.001). There was no conversion to on-pump surgery in the TAVRCAB group. The postoperative maximum creatinine kinase-MB value was lower in the TAVRCAB group. There was no deep sternal wound infection or repeat revascularisation in either group. Hospital death and brain infarction developed in one patient (1.3%) each in the SAVRCAB group, but in no patients in the TAVRCAB group. The rates of freedom from the composite event were similar between the two groups during the follow-up period. CONCLUSIONS: Concomitant off-pump CABG and TAVR would be a less-invasive alternative procedure for treating intermediate or high surgical risk patients with aortic stenosis and coronary artery disease unsuitable for percutaneous coronary intervention.
Assuntos
Estenose da Valva Aórtica , Ponte de Artéria Coronária sem Circulação Extracorpórea , Doença da Artéria Coronariana , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Valva Aórtica/cirurgia , Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/cirurgiaRESUMO
BACKGROUND: Size-mismatched heart transplantation( HTx) is associated with a risk of stenosis of the caval anastomosis site or low cardiac output syndrome. We developed a modified bicaval anastomosis technique( mBCAT) that achieved an adjustable caval anastomosis to compensate for the size mismatch. This study clarified clinical outcomes of HTx with mBCAT technique according to the degree of the size mismatch. METHODS AND RESULTS: This study consisted of 130 adult patients who underwent HTx with the mBCAT during a 22-year period and were followed up for at least 1 year. The cohort was divided into three groups according to the donor-to-recipient body weight ratio:<0.8, undersized group (n=19);0.8 ~1.3, size-matched group( n=89);and >1.3, oversized group( n=22). The undersized, size-matched, and oversized groups showed no significant differences in the rate of mild or worse tricuspid regurgitation on echocardiography at 1 month [ 1( 5.3%), 8( 9.0%), and 1( 4.6%), respectively;p=0.683] or the survival rate at 10 years( 100%, 96%, and 95%, respectively;p=0.452). The right heart catheter study revealed no pressure gradient across the orifices of both cavae in any patient. Additionally, the cardiac index immediately post-HTx was low in the undersized group, but improved over time in all groups, achieving the comparable value at 6 and 12 months post-HTx. CONCLUSIONS: The mBCAT prevented caval anastomosis-related complications in size-mismatched HTx and achieved excellent hemodynamics regardless of donor size.
Assuntos
Transplante de Coração , Insuficiência da Valva Tricúspide , Adulto , Anastomose Cirúrgica/métodos , Tamanho Corporal , Ecocardiografia , Transplante de Coração/métodos , Hemodinâmica , Humanos , Doadores de TecidosRESUMO
BACKGROUND: Implantable left ventricular assist devices (LVAD) have improved quality of life and survival in patients with advanced heart failure. However, LVAD-specific infections and predicting which patients will develop infections remain challenging. This study investigated whether changes in body mass index (BMI) during hospitalization following LVAD implantation are associated with LVAD-specific infections within 1 year of implantation.MethodsâandâResults:Patients (n=135) undergoing LVAD implantation were retrospectively divided into 2 groups based on changes in BMI from LVAD implantation to discharge: those with and without decreases in BMI. Each group was further subdivided according to baseline albumin concentrations (high [>3.7 g/dL] and low [≤3.7 g/dL]). Twenty patients developed LVAD-specific infections within 1 year. Receiver operating characteristic curve analysis resulted in a ∆BMI cut-off of less than -0.128 kg/m2. In multivariate analysis, younger patients and those with decreases in BMI had significantly higher rates of LVAD-specific infection (P=0.010 and P=0.035, respectively). LVAD-specific infection rates were significantly higher for patients with low albumin and decreases in BMI than for patients with low albumin but no decrease in BMI. CONCLUSIONS: Decreases in BMI during hospitalization after LVAD implantation and younger age were independently associated with LVAD-specific infection within 1 year. Strict patient management may be needed to avoid decreases in BMI during hospitalization after LVAD implantation, particularly in patients with low baseline albumin concentrations.
Assuntos
Coração Auxiliar , Índice de Massa Corporal , Coração Auxiliar/efeitos adversos , Humanos , Incidência , Qualidade de Vida , Estudos RetrospectivosRESUMO
Atrial tachycardia (AT) and atrial fibrillation (AF) commonly occur after cardiac surgeries (CSs). This study investigated the mechanisms and long-term outcomes of AT and AF ablation after various Maze procedures, particularly whether atrial tachyarrhythmias after the Maze procedure occur due to gaps in the Maze lines. We analyzed 37 consecutive cases with atrial tachyarrhythmias after the Maze procedures and concomitant CSs between 2007 and 2019. Fifty-nine atrial tachyarrhythmias were induced in 37 consecutive cases, and 49 of those atrial tachyarrhythmias were mappable ATs. Forty ATs were related to the Maze procedures in the 49 mappable ATs (81.6%). All 37 consecutive cases had residual electrical conductions (gaps) in the Maze lines (88 gaps; 2.4 ± 1.2 gaps/patient). Forty of 88 gaps (45.5%) were associated with gap-related ATs. The common ATs in this study were 1. peri-mitral atrial flutter due to gaps at pulmonary vein isolation (PVI) line to mitral valve annulus (MVA) (20 cases), and 2. peri-tricuspid atrial flutter due to gaps at right atrial incision to the tricuspid valve annulus (TVA) (10 cases). Forty-seven of 49 ATs (95.9%) were successfully ablated at the first session, and there were no complications. The mean follow-up period after ablation was 3.6 ± 3.2 (median, 2.1; interquartile range, 0.89-6.84) years. The Kaplan-Meier analysis of freedom from recurrent atrial tachyarrhythmias after Maze procedure was 82.7% at 1-year follow-up and 75.5% at 4-year follow-up after a single procedure. Reentry was the main mechanism of ATs after Maze procedures and concomitant CSs, and ATs were largely related to the gaps on the Maze lines between the PVI line and the MVA or those on the lines between right atrial incision to the TVA. Long-term follow-up data suggest that catheter ablation of atrial tachyarrhythmias after various Maze procedures is effective and safe.