Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Am J Obstet Gynecol ; 222(6): 604.e1-604.e10, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31954157

RESUMO

BACKGROUND: Over the years, there has been an increasing interest in the assessment of maternal hemodynamic responses during pregnancy. With the use of both noninvasive devices and/or maternal echocardiography, it has been shown that mothers who have pregnancy complications have altered hemodynamics compared with those who have uncomplicated pregnancies. It also has been suggested that preexisting maternal cardiac changes might drive the development of complications in pregnancy that are associated with impaired placentation. To understand, however, this potential link in complicated pregnancies, it is important to clarify whether placental function is associated with maternal cardiac functional indices in normal pregnancies. OBJECTIVE: To determine whether placental function, perfusion, and fetal weight are associated with maternal cardiac hemodynamic responses at 35-36 weeks of gestation in normal pregnancies. STUDY DESIGN: Prospective screening of women attending Kings' College Hospital for routine hospital visit at 35-37 weeks' gestation. We recorded maternal characteristics and measured mean arterial pressure, uterine artery pulsatility index, sonographic estimated fetal weight, and serum placental growth factor and soluble fms-like tyrosine kinase 1. We also performed maternal echocardiogram to assess cardiac output and peripheral vascular resistance as well as indices of diastolic and systolic function, including global longitudinal systolic function and left ventricular mass indexed to body surface area. RESULTS: We studied 1386 women. Maternal characteristics were associated with both maternal hemodynamics and functional and structural indices. Uterine artery pulsatility index was associated with left ventricular mass (P=.03) and global longitudinal systolic function (P=.017). There were significant nonlinear associations between placental growth factor and cardiac output and peripheral vascular resistance (P<.001 for both) and between soluble fms-like tyrosine kinase 1 and peripheral vascular resistance (P=.018). Estimated fetal weight was associated with maternal cardiac output (mean increase=0.186, 95% confidence interval, 0.133-0.238, P<.001) and peripheral vascular resistance (mean decrease=-0.164, 95% confidence interval, -0.217 to -0.111, P<.001). No association was noted between placental and fetal parameters and maternal cardiac functional and structural indices. In multivariable analysis, placental growth factor remained strongly associated with maternal cardiac output and peripheral vascular resistance (P=.002 for both) over and above maternal characteristics and estimated fetal weight. Estimated fetal weight was associated with left ventricular mass (0.102, 95% confidence interval, 0.044-0.162, P=.001). CONCLUSION: The results of this study suggest a strong link between maternal hemodynamic responses and fetoplacental needs across the whole spectrum in normal pregnancies. These findings would also indicate that to diagnose maternal cardiac dysfunction in pregnancies complicated by impaired placentation a more extensive echocardiographic assessment might be needed rather than relying on hemodynamics which are strongly associated with fetoplacental indices.


Assuntos
Pressão Arterial/fisiologia , Débito Cardíaco/fisiologia , Peso Fetal/fisiologia , Fator de Crescimento Placentário/metabolismo , Artéria Uterina/diagnóstico por imagem , Resistência Vascular/fisiologia , Adulto , Ecocardiografia , Ecocardiografia Doppler , Feminino , Idade Gestacional , Ventrículos do Coração/diagnóstico por imagem , Hemodinâmica , Humanos , Placenta/diagnóstico por imagem , Placenta/fisiologia , Gravidez , Terceiro Trimestre da Gravidez , Fluxo Pulsátil , Ultrassonografia Doppler , Ultrassonografia Pré-Natal , Artéria Uterina/fisiologia , Receptor 1 de Fatores de Crescimento do Endotélio Vascular/metabolismo , Função Ventricular/fisiologia
2.
Diagnostics (Basel) ; 13(12)2023 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-37370902

RESUMO

BACKGROUND: Hypertensive disorders of pregnancy (HDP) have been associated with increased cardiovascular risk for the mother and her offspring. However, it remains unknown whether cardiovascular changes are present in the postpartum period. METHODS: This was a cross-sectional study of women with singleton pregnancies. We recruited 33 women (20 following preeclampsia and 13 following gestational hypertension) and an equal number of women with uncomplicated pregnancy. Conventional and more advanced echocardiographic modalities such as speckle tracking were used to assess maternal and offspring cardiac function at 3-9 months postpartum. RESULTS: In women with HDP compared to those without, there was higher mean arterial pressure (mean 92.3 (SD 7.3) vs. 86.8 (8.3) mmHg, p = 0.007), left-ventricular mass indexed for body-surface area (64.5 (10.5) vs. 56.8 (10.03), p < 0.003), and E/e' (3.6 (0.8) vs. 3.1 (0.9), p = 0.022). There were no significant differences between groups in maternal left-ventricular systolic-functional indices and in offspring cardiac function between groups. CONCLUSIONS: At 3-9 months postpartum, mothers with HDP had higher blood pressure, higher left-ventricular mass, and reduced left-ventricular diastolic function. However, in their offspring, cardiac function was preserved. These findings suggest that mothers who experienced an HDP would benefit from cardio-obstetric follow-up in the postpartum period.

3.
Viruses ; 15(12)2023 12 05.
Artigo em Inglês | MEDLINE | ID: mdl-38140627

RESUMO

Pregnant women are especially vulnerable to respiratory diseases. We aimed to study seroconversion rates during pregnancy in a cohort of consecutive pregnancies tested in the first and third trimesters and to compare the maternal and obstetric complications in the women who seroconverted in the first trimester and those who did so in the third. This was an observational cohort study carried out at the Hospital Universitario de Torrejón, in Madrid, Spain, during the first peak of the COVID-19 pandemic. All consecutive singleton pregnancies with a viable fetus attending their 11-13-week scan between 1 January and 15 May 2020 were included and seropositive women for SARS-CoV2 were monthly follow up until delivery. Antibodies against SARS-CoV-2 (IgA and IgG) were analyzed on stored serum samples obtained from first- and third-trimester routine antenatal bloods in 470 pregnant women. Antibodies against SARS-CoV-2 were detected in 31 (6.6%) women in the first trimester and in 66 (14.0%) in the third trimester, including 48 (10.2%) that were negative in the first trimester (seroconversion during pregnancy). Although the rate of infection was significantly higher in the third versus the first trimester (p = 0.003), no significant differences in maternal or obstetric complications were observed in women testing positive in the first versus the third trimester.


Assuntos
COVID-19 , Soropositividade para HIV , Complicações Infecciosas na Gravidez , Feminino , Humanos , Gravidez , Estudos de Coortes , Pandemias , Complicações Infecciosas na Gravidez/epidemiologia , Terceiro Trimestre da Gravidez , RNA Viral , SARS-CoV-2 , Soroconversão
4.
Hypertension ; 76(2): 514-522, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32564692

RESUMO

Preeclampsia at term accounts for half of maternal deaths from hypertensive disorders. We aimed to assess differences in maternal cardiac indices at 35+0 to 36+6 weeks' gestation between women who subsequently developed preeclampsia at term compared with those with uncomplicated pregnancy and to evaluate whether cardiac indices offer incremental prognostic value to the available screening algorithm for preeclampsia. We recruited 1602 women with singleton pregnancies who attended for a routine hospital visit at 35+0 to 36+6 weeks' gestation between April and November 2018. We recorded maternal characteristics and preeclampsia-risk-score derived from a competing risks model and measured cardiac indices. Preeclampsia developed in 3.12% (50/1602) of participants. Women with preeclampsia, compared with those without, had increased mean arterial pressure (97.6, SD, 5.53 versus 87.9, SD, 6.82 mm Hg), systemic vascular resistance (1500, interquartile range, 1393-1831 versus 1400, interquartile range, 1202-1630 PRU) and preeclampsia-risk-score (23.4, interquartile range, 9.13-40 versus 0.9, interquartile range, 0.32-3.25). Multivariable analysis demonstrated independent association between the incidence of preeclampsia and E/e' (hazard ratio, 1.19/unit [95% CI, 1.03-1.37]; P=0.018) as well as left ventricular mass indexed for body surface area (hazard ratio, 1.03/[g·m2] [95% CI, 1.003-1.051]; P=0.029). Women with E/e' ≥7.3 and left ventricular mass indexed for body surface area ≥63.2 g/m2 had an increased risk for developing preeclampsia, despite low preeclampsia-risk-score <5% (hazard ratio, 20.1 [95% CI, 10.5-38.7], P<0.001). Increased left ventricular mass and E/e' offer incremental information to available scoring systems and better stratify women at risk of developing preeclampsia at term.


Assuntos
Pressão Arterial/fisiologia , Pré-Eclâmpsia/diagnóstico , Adulto , Feminino , Humanos , Programas de Rastreamento , Pré-Eclâmpsia/fisiopatologia , Gravidez , Terceiro Trimestre da Gravidez , Prognóstico , Medição de Risco , Fatores de Risco
5.
J Am Soc Echocardiogr ; 33(9): 1141-1146.e2, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32423727

RESUMO

BACKGROUND: There is a growing body of research on fetal speckle-tracking echocardiography because it is considered to be an angle-independent modality. The primary aim of this study was to investigate whether angle of insonation and acquisition frame rate (FR) influence left ventricular endocardial global longitudinal peak strain (GLS) in the fetus. METHODS: Four-chamber views of 122 healthy fetuses were studied at three different angles of insonation (apex up/down, apex oblique, and apex perpendicular) at high and low acoustic FRs. GLS was calculated, and a linear mixed-model analysis was used for analysis. Six hundred fifty-six fetal echocardiographic clips were analyzed (288 in the second trimester, at a median gestation of 21 weeks [interquartile range (IQR), 1 week], and 368 in the third trimester, at a median gestation of 36 weeks [IQR, 2 weeks]). RESULTS: Angle of insonation and FRs were significant determinants of GLS. Ventricular septum perpendicular to the ultrasound beam was associated with higher (more negative) GLS compared with apex up/down (at high FR: -21.8% vs -19.7%, P < .001; at low FR: -24.1% vs -21.4%, P < .001). Higher frames per second (FPS; median 149 FPS [IQR, 33 FPS] = 61 frames per cycle [FPC] [IQR, 17 FPC]) compared with lower FPS (median 51 FPS [IQR, 15 FPS] = 22 FPC [IQR, 7 FPC]) at the same insonation angle resulted in lower GLS (apex up/down: -19.7% vs -21.4%, P < .001; apex oblique: -21.2% vs -22.7%, P < .001; apex perpendicular: -21.8% vs -24.1%, P < .001). CONCLUSIONS: The present findings show that insonation angle and FR influence GLS significantly. These factors need to be considered when comparing studies with different acquisition protocols, when establishing normative values, and when interpreting pathology. Speckle-tracking echocardiography cannot be considered an angle-independent modality during fetal life.


Assuntos
Ecocardiografia , Ventrículos do Coração , Feminino , Feto , Ventrículos do Coração/diagnóstico por imagem , Humanos , Gravidez , Terceiro Trimestre da Gravidez , Reprodutibilidade dos Testes , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA