Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 141
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Am J Epidemiol ; 192(2): 296-304, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35872598

RESUMO

We considered methods for transporting a prediction model for use in a new target population, both when outcome and covariate data for model development are available from a source population that has a different covariate distribution compared with the target population and when covariate data (but not outcome data) are available from the target population. We discuss how to tailor the prediction model to account for differences in the data distribution between the source population and the target population. We also discuss how to assess the model's performance (e.g., by estimating the mean squared prediction error) in the target population. We provide identifiability results for measures of model performance in the target population for a potentially misspecified prediction model under a sampling design where the source and the target population samples are obtained separately. We introduce the concept of prediction error modifiers that can be used to reason about tailoring measures of model performance to the target population. We illustrate the methods in simulated data and apply them to transport a prediction model for lung cancer diagnosis from the National Lung Screening Trial to the nationally representative target population of trial-eligible individuals in the National Health and Nutrition Examination Survey.


Assuntos
Modelos Teóricos , Inquéritos Nutricionais , Humanos , Neoplasias Pulmonares/diagnóstico
2.
J Natl Compr Canc Netw ; 21(9): 915-923.e1, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37673107

RESUMO

BACKGROUND: Observational data investigating the relationship between body habitus and outcomes in breast cancer have been variable and inconsistent, largely centered in the curative setting and focused on weight-based metrics. This study evaluated the impact of muscle measures on outcomes in patients with metastatic breast cancer receiving endocrine-based therapy. METHODS: Baseline CT scans were collected from ECOG-ACRIN E2112, a randomized phase III placebo-controlled study of exemestane with or without entinostat. A CT cross-sectional image at the L3 level was extracted to obtain skeletal muscle mass and attenuation. Low muscle mass (LMM) was defined as skeletal muscle index <41 cm2/m2 and low muscle attenuation (LMA) as muscle density <25 HU or <33 HU if overweight/obese by body mass index (BMI). Multivariable Cox proportional hazard models determined the association between LMM or LMA and progression-free survival (PFS) and overall survival (OS). Correlations between LMM, LMA, and patient-reported outcomes were determined using 2-sample t tests. RESULTS: Analyzable CT scans and follow-up data were available for 540 of 608 patients. LMM was present in 39% (n=212) of patients and LMA in 56% (n=301). Those with LMA were more likely to have obesity and worse performance status. LMM was not associated with survival (PFS hazard ratio [HR]: 1.13, P=.23; OS HR: 1.05, P=.68), nor was LMA (PFS HR: 1.01, P=.93; OS HR: 1.00, P=.99). BMI was not associated with survival. LMA, but not LMM, was associated with increased frequency of patient-reported muscle aches. CONCLUSIONS: Both low muscle mass and density are prevalent in patients with hormone receptor-positive metastatic breast cancer. Muscle measures correlated with obesity and performance status; however, neither muscle mass nor attenuation were associated with prognosis. Further work is needed to refine body composition measurements and select optimal cutoffs with meaningful endpoints in specific breast cancer populations, particularly those living with metastatic disease.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/tratamento farmacológico , Músculo Esquelético/diagnóstico por imagem , Benchmarking , Índice de Massa Corporal , Obesidade/complicações
3.
Biometrics ; 79(3): 2382-2393, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36385607

RESUMO

We propose methods for estimating the area under the receiver operating characteristic (ROC) curve (AUC) of a prediction model in a target population that differs from the source population that provided the data used for original model development. If covariates that are associated with model performance, as measured by the AUC, have a different distribution in the source and target populations, then AUC estimators that only use data from the source population will not reflect model performance in the target population. Here, we provide identification results for the AUC in the target population when outcome and covariate data are available from the sample of the source population, but only covariate data are available from the sample of the target population. In this setting, we propose three estimators for the AUC in the target population and show that they are consistent and asymptotically normal. We evaluate the finite-sample performance of the estimators using simulations and use them to estimate the AUC in a nationally representative target population from the National Health and Nutrition Examination Survey for a lung cancer risk prediction model developed using source population data from the National Lung Screening Trial.


Assuntos
Modelos Estatísticos , Curva ROC , Inquéritos Nutricionais , Área Sob a Curva
4.
Neuroimage ; 246: 118775, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34890793

RESUMO

The reference standard for amyloid-PET quantification requires structural MRI (sMRI) for preprocessing in both multi-site research studies and clinical trials. Here we describe rPOP (robust PET-Only Processing), a MATLAB-based MRI-free pipeline implementing non-linear warping and differential smoothing of amyloid-PET scans performed with any of the FDA-approved radiotracers (18F-florbetapir/FBP, 18F-florbetaben/FBB or 18F-flutemetamol/FLUTE). Each image undergoes spatial normalization based on weighted PET templates and data-driven differential smoothing, then allowing users to perform their quantification of choice. Prior to normalization, users can choose whether to automatically reset the origin of the image to the center of mass or proceed with the pipeline with the image as it is. We validate rPOP with n = 740 (514 FBP, 182 FBB, 44 FLUTE) amyloid-PET scans from the Imaging Dementia-Evidence for Amyloid Scanning - Brain Health Registry sub-study (IDEAS-BHR) and n = 1,518 scans from the Alzheimer's Disease Neuroimaging Initiative (n = 1,249 FBP, n = 269 FBB), including heterogeneous acquisition and reconstruction protocols. After running rPOP, a standard quantification to extract Standardized Uptake Value ratios and the respective Centiloids conversion was performed. rPOP-based amyloid status (using an independent pathology-based threshold of ≥24.4 Centiloid units) was compared with either local visual reads (IDEAS-BHR, n = 663 with complete valid data and reads available) or with amyloid status derived from an MRI-based PET processing pipeline (ADNI, thresholds of >20/>18 Centiloids for FBP/FBB). Finally, within the ADNI dataset, we tested the linear associations between rPOP- and MRI-based Centiloid values. rPOP achieved accurate warping for N = 2,233/2,258 (98.9%) in the first pass. Of the N = 25 warping failures, 24 were rescued with manual reorientation and origin reset prior to warping. We observed high concordance between rPOP-based amyloid status and both visual reads (IDEAS-BHR, Cohen's k = 0.72 [0.7-0.74], ∼86% concordance) or MRI-pipeline based amyloid status (ADNI, k = 0.88 [0.87-0.89], ∼94% concordance). rPOP- and MRI-pipeline based Centiloids were strongly linearly related (R2:0.95, p<0.001), with this association being significantly modulated by estimated PET resolution (ß= -0.016, p<0.001). rPOP provides reliable MRI-free amyloid-PET warping and quantification, leveraging widely available software and only requiring an attenuation-corrected amyloid-PET image as input. The rPOP pipeline enables the comparison and merging of heterogeneous datasets and is publicly available at https://github.com/leoiacca/rPOP.


Assuntos
Peptídeos beta-Amiloides/metabolismo , Encéfalo/diagnóstico por imagem , Disfunção Cognitiva/diagnóstico por imagem , Demência/diagnóstico por imagem , Neuroimagem/métodos , Tomografia por Emissão de Pósitrons/métodos , Idoso , Idoso de 80 Anos ou mais , Encéfalo/metabolismo , Disfunção Cognitiva/metabolismo , Demência/metabolismo , Feminino , Humanos , Masculino
5.
Radiology ; 301(1): 66-77, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34342501

RESUMO

Background There are limited data from clinical trials describing preoperative MRI features and performance in the evaluation of mammographically detected ductal carcinoma in situ (DCIS). Purpose To report qualitative MRI features of DCIS, MRI performance in the identification of additional disease, and associations of imaging features with pathologic, genomic, and surgical outcomes from the Eastern Cooperative Oncology Group-American College of Radiology Imaging Network (ECOG-ACRIN) E4112 trial. Materials and Methods Secondary analyses of a multicenter prospective clinical trial from the ECOG-ACRIN Cancer Research Group included women with DCIS diagnosed with conventional imaging techniques (mammography and US), confirmed via core-needle biopsy (CNB), and enrolled between March 2015 and April 2016 who were candidates for wide local excision (WLE) based on conventional imaging and clinical examination results. DCIS MRI features and pathologic features from CNB and excision were recorded. Each woman without invasive upgrade of the index DCIS at WLE received a 12-gene DCIS score. MRI performance metrics were calculated. Associations of imaging features with invasive upgrade, dichotomized DCIS score (<39 vs ≥39), and single WLE success were estimated in uni- and multivariable analyses. Results Among 339 women (median age, 60 years; interquartile range, 51-66 years), most DCIS cases showed nonmass enhancement (NME) (195 of 339 [58%]) on MRI scans with larger median size than on mammograms (19 mm vs 12 mm; P < .001). Positive predictive value of MRI-prompted CNBs was 32% (21 of 66) (95% CI: 22, 44), yielding an additional cancer detection rate of 6.2% (21 of 339) (95% CI: 4.1, 9.3). MRI false-positive rate was 14.2% (45 of 318) (95% CI: 10.7, 18.4). No imaging features were associated with invasive upgrade or DCIS score (P = .05 to P = .95). Smaller size and focal NME distribution at MRI were linked to single WLE success (P < .001). Conclusion Preoperative MRI depicted ductal carcinoma in situ (DCIS) diagnosed with conventional imaging most commonly as nonmass enhancement, with larger median span than mammography, and additional cancer detection rate of 6.2%. MRI features of this subset of DCIS did not enable prediction of pathologic or genomic outcomes. Clinical trial registration no. NCT02352883 © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Kuhl in this issue. An earlier incorrect version of this article appeared online. This article was corrected on August 4, 2021.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Cuidados Pré-Operatórios/métodos , Idoso , Mama/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
7.
Alzheimers Dement ; 17(12): 2043-2055, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34018654

RESUMO

Patients with early-onset Alzheimer's disease (EOAD) are commonly excluded from large-scale observational and therapeutic studies due to their young age, atypical presentation, or absence of pathogenic mutations. The goals of the Longitudinal EOAD Study (LEADS) are to (1) define the clinical, imaging, and fluid biomarker characteristics of EOAD; (2) develop sensitive cognitive and biomarker measures for future clinical and research use; and (3) establish a trial-ready network. LEADS will follow 400 amyloid beta (Aß)-positive EOAD, 200 Aß-negative EOnonAD that meet National Institute on Aging-Alzheimer's Association (NIA-AA) criteria for mild cognitive impairment (MCI) or AD dementia, and 100 age-matched controls. Participants will undergo clinical and cognitive assessments, magnetic resonance imaging (MRI), [18 F]Florbetaben and [18 F]Flortaucipir positron emission tomography (PET), lumbar puncture, and blood draw for DNA, RNA, plasma, serum and peripheral blood mononuclear cells, and post-mortem assessment. To develop more effective AD treatments, scientists need to understand the genetic, biological, and clinical processes involved in EOAD. LEADS will develop a public resource that will enable future planning and implementation of EOAD clinical trials.


Assuntos
Doença de Alzheimer , Biomarcadores , Encéfalo , Diagnóstico Precoce , Doença de Alzheimer/genética , Doença de Alzheimer/patologia , Compostos de Anilina , Autopsia , Biomarcadores/sangue , Biomarcadores/líquido cefalorraquidiano , Biomarcadores/metabolismo , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Disfunção Cognitiva/genética , Disfunção Cognitiva/patologia , Feminino , Humanos , Estudos Longitudinais , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , National Institute on Aging (U.S.) , Tomografia por Emissão de Pósitrons , Estilbenos , Estados Unidos
8.
JAMA ; 323(8): 746-756, 2020 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-32096852

RESUMO

Importance: Improved screening methods for women with dense breasts are needed because of their increased risk of breast cancer and of failed early diagnosis by screening mammography. Objective: To compare the screening performance of abbreviated breast magnetic resonance imaging (MRI) and digital breast tomosynthesis (DBT) in women with dense breasts. Design, Setting, and Participants: Cross-sectional study with longitudinal follow-up at 48 academic, community hospital, and private practice sites in the United States and Germany, conducted between December 2016 and November 2017 among average-risk women aged 40 to 75 years with heterogeneously dense or extremely dense breasts undergoing routine screening. Follow-up ascertainment of cancer diagnoses was complete through September 12, 2019. Exposures: All women underwent screening by both DBT and abbreviated breast MRI, performed in randomized order and read independently to avoid interpretation bias. Main Outcomes and Measures: The primary end point was the invasive cancer detection rate. Secondary outcomes included sensitivity, specificity, additional imaging recommendation rate, and positive predictive value (PPV) of biopsy, using invasive cancer and ductal carcinoma in situ (DCIS) to define a positive reference standard. All outcomes are reported at the participant level. Pathology of core or surgical biopsy was the reference standard for cancer detection rate and PPV; interval cancers reported until the next annual screen were included in the reference standard for sensitivity and specificity. Results: Among 1516 enrolled women, 1444 (median age, 54 [range, 40-75] years) completed both examinations and were included in the analysis. The reference standard was positive for invasive cancer with or without DCIS in 17 women and for DCIS alone in another 6. No interval cancers were observed during follow-up. Abbreviated breast MRI detected all 17 women with invasive cancer and 5 of 6 women with DCIS. Digital breast tomosynthesis detected 7 of 17 women with invasive cancer and 2 of 6 women with DCIS. The invasive cancer detection rate was 11.8 (95% CI, 7.4-18.8) per 1000 women for abbreviated breast MRI vs 4.8 (95% CI, 2.4-10.0) per 1000 women for DBT, a difference of 7 (95% CI, 2.2-11.6) per 1000 women (exact McNemar P = .002). For detection of invasive cancer and DCIS, sensitivity was 95.7% (95% CI, 79.0%-99.2%) with abbreviated breast MRI vs 39.1% (95% CI, 22.2%-59.2%) with DBT (P = .001) and specificity was 86.7% (95% CI, 84.8%-88.4%) vs 97.4% (95% CI, 96.5%-98.1%), respectively (P < .001). The additional imaging recommendation rate was 7.5% (95% CI, 6.2%-9.0%) with abbreviated breast MRI vs 10.1% (95% CI, 8.7%-11.8%) with DBT (P = .02) and the PPV was 19.6% (95% CI, 13.2%-28.2%) vs 31.0% (95% CI, 17.0%-49.7%), respectively (P = .15). Conclusions and Relevance: Among women with dense breasts undergoing screening, abbreviated breast MRI, compared with DBT, was associated with a significantly higher rate of invasive breast cancer detection. Further research is needed to better understand the relationship between screening methods and clinical outcome. Trial Registration: ClinicalTrials.gov Identifier: NCT02933489.


Assuntos
Densidade da Mama , Neoplasias da Mama/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Imageamento por Ressonância Magnética , Mamografia , Invasividade Neoplásica/diagnóstico por imagem , Adulto , Idoso , Mama/diagnóstico por imagem , Estudos Transversais , Feminino , Seguimentos , Humanos , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Pessoa de Meia-Idade , Sensibilidade e Especificidade
9.
Stat Med ; 38(11): 1968-1990, 2019 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-30590870

RESUMO

In this paper, we develop methods to combine multiple biomarker trajectories into a composite diagnostic marker using functional data analysis (FDA) to achieve better diagnostic accuracy in monitoring disease recurrence in the setting of a prospective cohort study. In such studies, the disease status is usually verified only for patients with a positive test result in any biomarker and is missing in patients with negative test results in all biomarkers. Thus, the test result will affect disease verification, which leads to verification bias if the analysis is restricted only to the verified cases. We treat verification bias as a missing data problem. Under both missing at random (MAR) and missing not at random (MNAR) assumptions, we derive the optimal classification rules using the Neyman-Pearson lemma based on the composite diagnostic marker. We estimate thresholds adjusted for verification bias to dichotomize patients as test positive or test negative, and we evaluate the diagnostic accuracy using the verification bias corrected area under the ROC curves (AUCs). We evaluate the performance and robustness of the FDA combination approach and assess the consistency of the approach through simulation studies. In addition, we perform a sensitivity analysis of the dependency between the verification process and disease status for the approach under the MNAR assumption. We apply the proposed method on data from the Religious Orders Study and from a non-small cell lung cancer trial.


Assuntos
Viés , Biomarcadores , Testes Diagnósticos de Rotina/normas , Algoritmos , Área Sob a Curva , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Humanos , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes
10.
JAMA ; 321(13): 1286-1294, 2019 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-30938796

RESUMO

Importance: Amyloid positron emission tomography (PET) detects amyloid plaques in the brain, a core neuropathological feature of Alzheimer disease. Objective: To determine if amyloid PET is associated with subsequent changes in the management of patients with mild cognitive impairment (MCI) or dementia of uncertain etiology. Design, Setting, and Participants: The Imaging Dementia-Evidence for Amyloid Scanning (IDEAS) study was a single-group, multisite longitudinal study that assessed the association between amyloid PET and subsequent changes in clinical management for Medicare beneficiaries with MCI or dementia. Participants were required to meet published appropriate use criteria stating that etiology of cognitive impairment was unknown, Alzheimer disease was a diagnostic consideration, and knowledge of PET results was expected to change diagnosis and management. A total of 946 dementia specialists at 595 US sites enrolled 16 008 patients between February 2016 and September 2017. Patients were followed up through January 2018. Dementia specialists documented their diagnosis and management plan before PET and again 90 (±30) days after PET. Exposures: Participants underwent amyloid PET at 343 imaging centers. Main Outcomes and Measures: The primary end point was change in management between the pre- and post-PET visits, as assessed by a composite outcome that included Alzheimer disease drug therapy, other drug therapy, and counseling about safety and future planning. The study was powered to detect a 30% or greater change in the MCI and dementia groups. One of 2 secondary end points is reported: the proportion of changes in diagnosis (from Alzheimer disease to non-Alzheimer disease and vice versa) between pre- and post-PET visits. Results: Among 16 008 registered participants, 11 409 (71.3%) completed study procedures and were included in the analysis (median age, 75 years [interquartile range, 71-80]; 50.9% women; 60.5% with MCI). Amyloid PET results were positive in 3817 patients with MCI (55.3%) and 3154 patients with dementia (70.1%). The composite end point changed in 4159 of 6905 patients with MCI (60.2% [95% CI, 59.1%-61.4%]) and 2859 of 4504 patients with dementia (63.5% [95% CI, 62.1%-64.9%]), significantly exceeding the 30% threshold in each group (P < .001, 1-sided). The etiologic diagnosis changed from Alzheimer disease to non-Alzheimer disease in 2860 of 11 409 patients (25.1% [95% CI, 24.3%-25.9%]) and from non-Alzheimer disease to Alzheimer disease in 1201 of 11 409 (10.5% [95% CI, 10.0%-11.1%]). Conclusions and Relevance: Among Medicare beneficiaries with MCI or dementia of uncertain etiology evaluated by dementia specialists, the use of amyloid PET was associated with changes in clinical management within 90 days. Further research is needed to determine whether amyloid PET is associated with improved clinical outcomes. Trial Registration: ClinicalTrials.gov Identifier: NCT02420756.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Disfunção Cognitiva/diagnóstico por imagem , Demência/diagnóstico por imagem , Nootrópicos/uso terapêutico , Placa Amiloide/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/tratamento farmacológico , Amiloide , Disfunção Cognitiva/terapia , Demência/etiologia , Demência/terapia , Diagnóstico Diferencial , Feminino , Humanos , Estudos Longitudinais , Masculino , Medicare , Estados Unidos
12.
JAMA ; 319(4): 388-396, 2018 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-29362800

RESUMO

Importance: Systematic reviews of diagnostic test accuracy synthesize data from primary diagnostic studies that have evaluated the accuracy of 1 or more index tests against a reference standard, provide estimates of test performance, allow comparisons of the accuracy of different tests, and facilitate the identification of sources of variability in test accuracy. Objective: To develop the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) diagnostic test accuracy guideline as a stand-alone extension of the PRISMA statement. Modifications to the PRISMA statement reflect the specific requirements for reporting of systematic reviews and meta-analyses of diagnostic test accuracy studies and the abstracts for these reviews. Design: Established standards from the Enhancing the Quality and Transparency of Health Research (EQUATOR) Network were followed for the development of the guideline. The original PRISMA statement was used as a framework on which to modify and add items. A group of 24 multidisciplinary experts used a systematic review of articles on existing reporting guidelines and methods, a 3-round Delphi process, a consensus meeting, pilot testing, and iterative refinement to develop the PRISMA diagnostic test accuracy guideline. The final version of the PRISMA diagnostic test accuracy guideline checklist was approved by the group. Findings: The systematic review (produced 64 items) and the Delphi process (provided feedback on 7 proposed items; 1 item was later split into 2 items) identified 71 potentially relevant items for consideration. The Delphi process reduced these to 60 items that were discussed at the consensus meeting. Following the meeting, pilot testing and iterative feedback were used to generate the 27-item PRISMA diagnostic test accuracy checklist. To reflect specific or optimal contemporary systematic review methods for diagnostic test accuracy, 8 of the 27 original PRISMA items were left unchanged, 17 were modified, 2 were added, and 2 were omitted. Conclusions and Relevance: The 27-item PRISMA diagnostic test accuracy checklist provides specific guidance for reporting of systematic reviews. The PRISMA diagnostic test accuracy guideline can facilitate the transparent reporting of reviews, and may assist in the evaluation of validity and applicability, enhance replicability of reviews, and make the results from systematic reviews of diagnostic test accuracy studies more useful.


Assuntos
Lista de Checagem , Técnicas e Procedimentos Diagnósticos , Guias como Assunto , Metanálise como Assunto , Revisões Sistemáticas como Assunto , Conferências de Consenso como Assunto , Técnica Delphi , Técnicas e Procedimentos Diagnósticos/normas , Reprodutibilidade dos Testes
14.
N Engl J Med ; 371(19): 1793-802, 2014 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-25372087

RESUMO

BACKGROUND: The National Lung Screening Trial (NLST) showed that screening with low-dose computed tomography (CT) as compared with chest radiography reduced lung-cancer mortality. We examined the cost-effectiveness of screening with low-dose CT in the NLST. METHODS: We estimated mean life-years, quality-adjusted life-years (QALYs), costs per person, and incremental cost-effectiveness ratios (ICERs) for three alternative strategies: screening with low-dose CT, screening with radiography, and no screening. Estimations of life-years were based on the number of observed deaths that occurred during the trial and the projected survival of persons who were alive at the end of the trial. Quality adjustments were derived from a subgroup of participants who were selected to complete quality-of-life surveys. Costs were based on utilization rates and Medicare reimbursements. We also performed analyses of subgroups defined according to age, sex, smoking history, and risk of lung cancer and performed sensitivity analyses based on several assumptions. RESULTS: As compared with no screening, screening with low-dose CT cost an additional $1,631 per person (95% confidence interval [CI], 1,557 to 1,709) and provided an additional 0.0316 life-years per person (95% CI, 0.0154 to 0.0478) and 0.0201 QALYs per person (95% CI, 0.0088 to 0.0314). The corresponding ICERs were $52,000 per life-year gained (95% CI, 34,000 to 106,000) and $81,000 per QALY gained (95% CI, 52,000 to 186,000). However, the ICERs varied widely in subgroup and sensitivity analyses. CONCLUSIONS: We estimated that screening for lung cancer with low-dose CT would cost $81,000 per QALY gained, but we also determined that modest changes in our assumptions would greatly alter this figure. The determination of whether screening outside the trial will be cost-effective will depend on how screening is implemented. (Funded by the National Cancer Institute; NLST ClinicalTrials.gov number, NCT00047385.).


Assuntos
Detecção Precoce de Câncer/economia , Expectativa de Vida , Neoplasias Pulmonares/mortalidade , Pulmão/diagnóstico por imagem , Anos de Vida Ajustados por Qualidade de Vida , Radiografia Torácica/economia , Tomografia Computadorizada por Raios X/economia , Idoso , Análise Custo-Benefício , Feminino , Custos de Cuidados de Saúde , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/economia , Neoplasias Pulmonares/cirurgia , Masculino , Pessoa de Meia-Idade , Fumar , Inquéritos e Questionários , Estados Unidos
15.
J Magn Reson Imaging ; 46(1): 290-302, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-27981651

RESUMO

PURPOSE: To estimate the accuracy of predicting response to neoadjuvant chemotherapy (NACT) in patients with locally advanced breast cancer using MR spectroscopy (MRS) measurements made very early in treatment. MATERIALS AND METHODS: This prospective Health Insurance Portability and Accountability Act (HIPAA)-compliant protocol was approved by the American College of Radiology and local-site institutional review boards. One hundred nineteen women with invasive breast cancer of ≥3 cm undergoing NACT were enrolled between September 2007 and April 2010. MRS measurements of the concentration of choline-containing compounds ([tCho]) were performed before the first chemotherapy regimen (time point 1, TP1) and 20-96 h after the first cycle of treatment (TP2). The change in [tCho] was assessed for its ability to predict pathologic complete response (pCR) and radiologic response using the area under the receiver operating characteristic curve (AUC) and logistic regression models. RESULTS: Of the 119 subjects enrolled, only 29 cases (24%) with eight pCRs provided usable data for the primary analysis. Technical challenges in acquiring quantitative MRS data in a multi-site trial setting limited the capture of usable data. In this limited data set, the decrease in tCho from TP1 to TP2 had poor ability to predict either pCR (AUC = 0.53, 95% confidence interval [CI]: 0.27-0.79) or radiologic response (AUC = 0.51, 95% CI: 0.27-0.75). CONCLUSION: The technical difficulty of acquiring quantitative MRS data in a multi-site clinical trial setting led to a low yield of analyzable data, which was insufficient to accurately measure the ability of early MRS measurements to predict response to NACT. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:290-302.


Assuntos
Algoritmos , Biomarcadores Tumorais/análise , Neoplasias da Mama/química , Neoplasias da Mama/terapia , Colina/análise , Espectroscopia de Ressonância Magnética/métodos , Prevenção Secundária/métodos , Adulto , Idoso , Neoplasias da Mama/diagnóstico , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Molecular/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Clin Trials ; 14(2): 140-151, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28068789

RESUMO

Background/Aims Nursing homes are complex healthcare systems serving an increasingly sick population. Nursing homes must engage patients in advance care planning, but do so inconsistently. Video decision support tools improved advance care planning in small randomized controlled trials. Pragmatic trials are increasingly employed in health services research, although not commonly in the nursing home setting to which they are well-suited. This report presents the design and rationale for a pragmatic cluster randomized controlled trial that evaluated the "real world" application of an Advance Care Planning Video Program in two large US nursing home healthcare systems. Methods PRagmatic trial Of Video Education in Nursing homes was conducted in 360 nursing homes (N = 119 intervention/N = 241 control) owned by two healthcare systems. Over an 18-month implementation period, intervention facilities were instructed to offer the Advance Care Planning Video Program to all patients. Control facilities employed usual advance care planning practices. Patient characteristics and outcomes were ascertained from Medicare Claims, Minimum Data Set assessments, and facility electronic medical record data. Intervention adherence was measured using a Video Status Report embedded into electronic medical record systems. The primary outcome was the number of hospitalizations/person-day alive among long-stay patients with advanced dementia or cardiopulmonary disease. The rationale for the approaches to facility randomization and recruitment, intervention implementation, population selection, data acquisition, regulatory issues, and statistical analyses are discussed. Results The large number of well-characterized candidate facilities enabled several unique design features including stratification on historical hospitalization rates, randomization prior to recruitment, and 2:1 control to intervention facilities ratio. Strong endorsement from corporate leadership made randomization prior to recruitment feasible with 100% participation of facilities randomized to the intervention arm. Critical regulatory issues included minimal risk determination, waiver of informed consent, and determination that nursing home providers were not engaged in human subjects research. Intervention training and implementation were initiated on 5 January 2016 using corporate infrastructures for new program roll-out guided by standardized training elements designed by the research team. Video Status Reports in facilities' electronic medical records permitted "real-time" adherence monitoring and corrective actions. The Centers for Medicare and Medicaid Services Virtual Research Data Center allowed for rapid outcomes ascertainment. Conclusion We must rigorously evaluate interventions to deliver more patient-focused care to an increasingly frail nursing home population. Video decision support is a practical approach to improve advance care planning. PRagmatic trial Of Video Education in Nursing homes has the potential to promote goal-directed care among millions of older Americans in nursing homes and establish a methodology for future pragmatic randomized controlled trials in this complex healthcare setting.


Assuntos
Planejamento Antecipado de Cuidados , Recursos Audiovisuais , Técnicas de Apoio para a Decisão , Casas de Saúde , Educação de Pacientes como Assunto , Demência/terapia , Cardiopatias/terapia , Hospitalização , Humanos , Pneumopatias/terapia , Índice de Gravidade de Doença , Gravação em Vídeo
17.
Lancet Oncol ; 17(5): 590-9, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27009070

RESUMO

BACKGROUND: Annual low-dose CT screening for lung cancer has been recommended for high-risk individuals, but the necessity of yearly low-dose CT in all eligible individuals is uncertain. This study examined rates of lung cancer in National Lung Screening Trial (NLST) participants who had a negative prevalence (initial) low-dose CT screen to explore whether less frequent screening could be justified in some lower-risk subpopulations. METHODS: We did a retrospective cohort analysis of data from the NLST, a randomised, multicentre screening trial comparing three annual low-dose CT assessments with three annual chest radiographs for the early detection of lung cancer in high-risk, eligible individuals (aged 55-74 years with at least a 30 pack-year history of cigarette smoking, and, if a former smoker, had quit within the past 15 years), recruited from US medical centres between Aug 5, 2002, and April 26, 2004. Participants were followed up for up to 5 years after their last annual screen. For the purposes of this analysis, our cohort consisted of all NLST participants who had received a low-dose CT prevalence (T0) screen. We determined the frequency, stage, histology, study year of diagnosis, and incidence of lung cancer, as well as overall and lung cancer-specific mortality, and whether lung cancers were detected as a result of screening or within 1 year of a negative screen. We also estimated the effect on mortality if the first annual (T1) screen in participants with a negative T0 screen had not been done. The NLST is registered with ClinicalTrials.gov, number NCT00047385. FINDINGS: Our cohort consisted of 26 231 participants assigned to the low-dose CT screening group who had undergone their T0 screen. The 19 066 participants with a negative T0 screen had a lower incidence of lung cancer than did all 26 231 T0-screened participants (371·88 [95% CI 337·97-408·26] per 100 000 person-years vs 661·23 [622·07-702·21]) and had lower lung cancer-related mortality (185·82 [95% CI 162·17-211·93] per 100 000 person-years vs 277·20 [252·28-303·90]). The yield of lung cancer at the T1 screen among participants with a negative T0 screen was 0·34% (62 screen-detected cancers out of 18 121 screened participants), compared with a yield at the T0 screen among all T0-screened participants of 1·0% (267 of 26 231). We estimated that if the T1 screen had not been done in the T0 negative group, at most, an additional 28 participants in the T0 negative group would have died from lung cancer (a rise in mortality from 185·82 [95% CI 162·17-211·93] per 100 000 person-years to 212·14 [186·80-239·96]) over the course of the trial. INTERPRETATION: Participants with a negative low-dose CT prevalence screen had a lower incidence of lung cancer and lung cancer-specific mortality than did all participants who underwent a prevalence screen. Because overly frequent screening has associated harms, increasing the interval between screens in participants with a negative low-dose CT prevalence screen might be warranted. FUNDING: None.


Assuntos
Detecção Precoce de Câncer , Neoplasias Pulmonares/diagnóstico , Pulmão/patologia , Tomografia Computadorizada por Raios X , Idoso , Feminino , Humanos , Pulmão/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Fumar
18.
N Engl J Med ; 369(10): 920-31, 2013 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-24004119

RESUMO

BACKGROUND: The National Lung Screening Trial was conducted to determine whether three annual screenings (rounds T0, T1, and T2) with low-dose helical computed tomography (CT), as compared with chest radiography, could reduce mortality from lung cancer. We present detailed findings from the first two incidence screenings (rounds T1 and T2). METHODS: We evaluated the rate of adherence of the participants to the screening protocol, the results of screening and downstream diagnostic tests, features of the lung-cancer cases, and first-line treatments, and we estimated the performance characteristics of both screening methods. RESULTS: At the T1 and T2 rounds, positive screening results were observed in 27.9% and 16.8% of participants in the low-dose CT group and in 6.2% and 5.0% of participants in the radiography group, respectively. In the low-dose CT group, the sensitivity was 94.4%, the specificity was 72.6%, the positive predictive value was 2.4%, and the negative predictive value was 99.9% at T1; at T2, the positive predictive value increased to 5.2%. In the radiography group, the sensitivity was 59.6%, the specificity was 94.1%, the positive predictive value was 4.4%, and the negative predictive value was 99.8% at T1; both the sensitivity and the positive predictive value increased at T2. Among lung cancers of known stage, 87 (47.5%) were stage IA and 57 (31.1%) were stage III or IV in the low-dose CT group at T1; in the radiography group, 31 (23.5%) were stage IA and 78 (59.1%) were stage III or IV at T1. These differences in stage distribution between groups persisted at T2. CONCLUSIONS: Low-dose CT was more sensitive in detecting early-stage lung cancers, but its measured positive predictive value was lower than that of radiography. As compared with radiography, the two annual incidence screenings with low-dose CT resulted in a decrease in the number of advanced-stage cancers diagnosed and an increase in the number of early-stage lung cancers diagnosed. (Funded by the National Cancer Institute; NLST ClinicalTrials.gov number, NCT00047385.).


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Nódulo Pulmonar Solitário/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Valor Preditivo dos Testes , Radiografia Torácica , Sensibilidade e Especificidade , Tomografia Computadorizada Espiral
19.
Radiology ; 279(1): 44-55, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26624971

RESUMO

PURPOSE: To evaluate volumetric magnetic resonance (MR) imaging for predicting recurrence-free survival (RFS) after neoadjuvant chemotherapy (NACT) of breast cancer and to consider its predictive performance relative to pathologic complete response (PCR). MATERIALS AND METHODS: This HIPAA-compliant prospective multicenter study was approved by institutional review boards with written informed consent. Women with breast tumors 3 cm or larger scheduled for NACT underwent dynamic contrast-enhanced MR imaging before treatment (examination 1), after one cycle (examination 2), midtherapy (examination 3), and before surgery (examination 4). Functional tumor volume (FTV), computed from MR images by using enhancement thresholds, and change from baseline (ΔFTV) were measured after one cycle and before surgery. Association of RFS with FTV was assessed by Cox regression and compared with association of RFS with PCR and residual cancer burden (RCB), while controlling for age, race, and hormone receptor (HR)/ human epidermal growth factor receptor type 2 (HER2) status. Predictive performance of models was evaluated by C statistics. RESULTS: Female patients (n = 162) with FTV and RFS were included. At univariate analysis, FTV2, FTV4, and ΔFTV4 had significant association with RFS, as did HR/HER2 status and RCB class. PCR approached significance at univariate analysis and was not significant at multivariate analysis. At univariate analysis, FTV2 and RCB class had the strongest predictive performance (C statistic = 0.67; 95% confidence interval [CI]: 0.58, 0.76), greater than for FTV4 (0.64; 95% CI: 0.53, 0.74) and PCR (0.57; 95% CI: 0.39, 0.74). At multivariate analysis, a model with FTV2, ΔFTV2, RCB class, HR/HER2 status, age, and race had the highest C statistic (0.72; 95% CI: 0.60, 0.84). CONCLUSION: Breast tumor FTV measured by MR imaging is a strong predictor of RFS, even in the presence of PCR and RCB class. Models combining MR imaging, histopathology, and breast cancer subtype demonstrated the strongest predictive performance in this study.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Biópsia com Agulha de Grande Calibre , Ensaios Clínicos como Assunto , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Terapia Neoadjuvante , Valor Preditivo dos Testes , Resultado do Tratamento , Carga Tumoral , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA