Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Shoulder Elbow Surg ; 33(8): 1771-1780, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38281677

RESUMO

BACKGROUND: We aim to predict a clinical difference in the postoperative range of motion (RoM) between 2 reverse shoulder arthroplasty (RSA) stem designs (Inlay-155° and Onlay-145°) using preoperative planning software. We hypothesized that preoperative 3D planning could anticipate the differences in postoperative clinical RoM between 2 humeral stem designs and by keeping the same glenoid implant. METHODS: Thirty-seven patients (14 men and 23 women, 76 ± 7 years) underwent a BIO-RSA (bony increased offset-RSA) with the use of preoperative planning and an intraoperative 3-dimensional-printed patient-specific guide for glenoid component implantation between January 2014 and September 2019 with a minimum follow-up of 2 years. Two types of humeral implants were used: Inlay with a 155° inclination (Inlay-155°) and Onlay with a 145°inclination (Onlay-145°). Glenoid implants remained unchanged. The postoperative RSA angle (inclination of the area in which the glenoid component of the RSA is implanted) and the lateralization shoulder angle were measured to confirm the good positioning of the glenoid implant and the global lateralization on postoperative X-rays. A correlation between simulated and clinical RoM was studied. Simulated and last follow-up active forward flexion (AFE), abduction, and external rotation (ER) were compared between the 2 types of implants. RESULTS: No significant difference in RSA and lateralization shoulder angle was found between planned and postoperative radiological implants' position. Clinical RoM at the last follow-up was always significantly different from simulated preoperative RoM. A low-to-moderate but significant correlation existed for AFE, abduction, and ER (r = 0.45, r = 0.47, and r = 0.57, respectively; P < .01). AFE and abduction were systematically underestimated (126° ± 16° and 95° ± 13° simulated vs. 150° ± 24° and 114° ± 13° postoperatively; P < .001), whereas ER was systematically overestimated (50° ± 19° simulated vs. 36° ± 19° postoperatively; P < .001). Simulated abduction and ER highlighted a significant difference between Inlay-155° and Onlay-145° (12° ± 2°, P = .01, and 23° ± 3°, P < .001), and this was also retrieved clinically at the last follow-up (23° ± 2°, P = .02, and 22° ± 2°, P < .001). CONCLUSIONS: This study is the first to evaluate the clinical relevance of predicted RoM for RSA preoperative planning. Motion that involves the scapulothoracic joint (AFE and abduction) is underestimated, while ER is overestimated. However, preoperative planning provides clinically relevant RoM prediction with a significant correlation between both and brings reliable data when comparing 2 different types of humeral implants (Inlay-155° and Onlay-145°) for abduction and ER. Thus, RoM simulation is a valuable tool to optimize implant selection and choose RSA implants to reach the optimal RoM.


Assuntos
Artroplastia do Ombro , Desenho de Prótese , Amplitude de Movimento Articular , Articulação do Ombro , Prótese de Ombro , Humanos , Artroplastia do Ombro/métodos , Feminino , Amplitude de Movimento Articular/fisiologia , Masculino , Idoso , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Idoso de 80 Anos ou mais , Imageamento Tridimensional , Estudos Retrospectivos , Cuidados Pré-Operatórios/métodos , Impressão Tridimensional
2.
J Shoulder Elbow Surg ; 33(7): e347-e355, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38182028

RESUMO

BACKGROUND: Primary glenohumeral osteoarthritis is associated with both excessive posterior humeral subluxation (PHS) and excessive glenoid retroversion in 40% of cases. These morphometric abnormalities are a particular issue because they may be responsible for a deterioration in long-term clinical and radiologic outcomes. The aim of this study was to perform a computed tomographic (CT) analysis of patients who underwent total shoulder arthroplasty (TSA) for primary osteoarthritis (OA) with B2-, B3-, or C-type glenoids in whom an attempt was made to correct for excessive glenoid retroversion and excessive posterior humeral subluxation intraoperatively. MATERIAL: We performed a retrospective, single-center study including 62 TSA patients with a preoperative PHS of the glenohumeral joint (31 men, 31 women, 70 ± 9 years) between January 2000 and January 2014. Glenoids were classified as B2 (32 cases), B3 (13 cases), or C (17 cases). Glenoid retroversion was corrected by anterior asymmetric reaming. Patients were reviewed for clinical and CT scan assessment with a mean follow-up of 8.3 years (minimum 5 years). At final follow-up, the CT images were reconstructed in the scapular plane. A PHS index >65% defined persistence. RESULTS: The revision-free rate was estimated at 93%. Correlation between PHS and retroversion was moderate preoperatively (ρ = 0.58) and strong at final follow-up (ρ = 0.73). Postoperative CT scans on average showed a surgical correction of PHS compared to preoperatively (79% vs. 65% respectively, P < .05) and retroversion (20° vs. 10° respectively, P < .05). At final follow-up, 25 of 62 patients had a persistence in the 2-dimensional (2D) model and 41 of 62 in the corrected 2D model. Persistence of PHS had no influence on clinical outcomes but did demonstrate a significantly higher glenoid loosening rate (20% vs. 59%, P < .05). CONCLUSION: Correlation between PHS and retroversion was moderate preoperatively and strengthened at long-term follow-up. Anterior asymmetric reaming allowed for a surgical improvement of both PHS and retroversion, but it was not sufficient to maintain a correction over time. Glenoid loosening was more frequent in case of PHS persistence but seemingly without clinical relevance.


Assuntos
Artroplastia do Ombro , Osteoartrite , Articulação do Ombro , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Artroplastia do Ombro/métodos , Osteoartrite/cirurgia , Osteoartrite/diagnóstico por imagem , Idoso , Estudos Retrospectivos , Articulação do Ombro/cirurgia , Articulação do Ombro/diagnóstico por imagem , Pessoa de Meia-Idade , Seguimentos , Resultado do Tratamento , Amplitude de Movimento Articular , Fatores de Tempo , Idoso de 80 Anos ou mais , Luxação do Ombro/cirurgia , Luxação do Ombro/diagnóstico por imagem
3.
J Shoulder Elbow Surg ; 33(7): 1493-1502, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38242526

RESUMO

BACKGROUND: The etiology of humeral posterior subluxation remains unknown, and it has been hypothesized that horizontal muscle imbalance could cause this condition. The objective of this study was to compare the ratio of anterior-to-posterior rotator cuff and deltoid muscle volume as a function of humeral subluxation and glenoid morphology when analyzed as a continuous variable in arthritic shoulders. METHODS: In total, 333 computed tomography scans of shoulders (273 arthritic shoulders and 60 healthy controls) were included in this study and were segmented automatically. For each muscle, the volume of muscle fibers without intramuscular fat was measured. The ratio between the volume of the subscapularis and the volume of the infraspinatus plus teres minor (AP ratio) and the ratio between the anterior and posterior deltoids (APdeltoid) were calculated. Statistical analyses were performed to determine whether a correlation could be found between these ratios and glenoid version, humeral subluxation, and/or glenoid type per the Walch classification. RESULTS: Within the arthritic cohort, no statistically significant difference in the AP ratio was found between type A glenoids (1.09 ± 0.22) and type B glenoids (1.03 ± 0.16, P = .09), type D glenoids (1.12 ± 0.27, P = .77), or type C glenoids (1.10 ± 0.19, P > .999). No correlation was found between the AP ratio and glenoid version (ρ = -0.0360, P = .55) or humeral subluxation (ρ = 0.076, P = .21). The APdeltoid ratio of type A glenoids (0.48 ± 0.15) was significantly greater than that of type B glenoids (0.35 ± 0.16, P < .01) and type C glenoids (0.21 ± 0.10, P < .01) but was not significantly different from that of type D glenoids (0.64 ± 0.34, P > .999). When evaluating both healthy control and arthritic shoulders, moderate correlations were found between the APdeltoid ratio and both glenoid version (ρ = 0.55, P < .01) and humeral subluxation (ρ = -0.61, P < .01). CONCLUSION: This in vitro study supports the use of software for fully automated 3-dimensional reconstruction of the 4 rotator cuff muscles and the deltoid. Compared with previous 2-dimensional computed tomography scan studies, our study did not find any correlation between the anteroposterior muscle volume ratio and glenoid parameters in arthritic shoulders. However, once deformity occurred, the observed APdeltoid ratio was lower with type B and C glenoids. These findings suggest that rotator cuff muscle imbalance may not be the precipitating etiology for the posterior humeral subluxation and secondary posterior glenoid erosion characteristic of Walch type B glenoids.


Assuntos
Músculo Deltoide , Manguito Rotador , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Manguito Rotador/diagnóstico por imagem , Músculo Deltoide/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Luxação do Ombro/diagnóstico por imagem , Adulto , Estudos de Casos e Controles , Cavidade Glenoide/diagnóstico por imagem , Cavidade Glenoide/patologia , Úmero/diagnóstico por imagem , Retroversão Óssea/diagnóstico por imagem , Estudos Retrospectivos
4.
Int Orthop ; 48(2): 505-511, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37853140

RESUMO

PURPOSE: One-stage bilateral shoulder arthroplasty has the advantage of requiring a single hospital stay and a single anaesthesia. The topic has been little reported, unlike one stage bilateral hip and knee arthroplasty, which have demonstrated their interest. The aim of the present study was to determine peri- and early post-operative morbidity and mortality after this procedure. The study hypothesis was that peri- and early post-operative morbidity and mortality in one stage bilateral shoulder arthroplasty is low in selected patients and that satisfaction is high. METHODS: A single-centre retrospective study assessed peri- and early post-operative morbidity and mortality in one stage bilateral shoulder arthroplasty. Twenty-one patients, aged < 80 years, with ASA score ≤ 3, were consecutively operated on between 1999 and 2020. Indications comprised primary osteoarthritis, aseptic osteonecrosis, inflammatory arthritis, massive rotator cuff tear, and dislocation fracture, involving both shoulders. RESULTS: There were no early deaths. The complication rate was 10% (4/21 cases). No prosthesis dislocation or sepsis was reported. Mean blood loss was 145 ± 40 cc, mean surgery time 164 ± 63 min, and mean hospital stay five ± four days. Only one patient required postoperative transfusion. Functional results at six months showed significantly improved range of motion and good patient satisfaction. CONCLUSIONS: One-stage bilateral shoulder arthroplasty was feasible in selected patients. Mortality was zero, and morbidity was low. Surgery time was reasonable and required no repositioning. Postoperative home help is indispensable for patient satisfaction during rehabilitation.


Assuntos
Artroplastia do Joelho , Artroplastia do Ombro , Osteoartrite , Articulação do Ombro , Humanos , Osteoartrite/cirurgia , Estudos Retrospectivos , Artroplastia do Ombro/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Artroplastia do Joelho/efeitos adversos , Amplitude de Movimento Articular , Articulação do Ombro/cirurgia , Resultado do Tratamento
5.
Artigo em Inglês | MEDLINE | ID: mdl-38158039

RESUMO

INTRODUCTION: The etiology of humeral posterior subluxation remains unknown, and it has been hypothesized that horizontal muscle imbalance could cause this condition. The objective of this study was to compare the ratio of anterior to posterior rotator cuff muscle and deltoid volumes as a function of humeral subluxation and glenoid morphology when analyzed as continuous variable in arthritic shoulders. METHODS: Three hundred and thirty-three (273 arthritic and 60 healthy controls) CT scans of shoulders were included in this study and were segmented automatically. For each muscle, the volume of muscle fibers without intra-muscular fat was then measured. The ratio between the volume of the subscapularis and the volume of the infraspinatus + teres minor (AP ratio) and the ratio between the anterior and posterior deltoid (APdeltoid) were calculated. Statistical analyses were performed to determine whether a correlation could be found between these ratios and glenoid version/ humeral subluxation/glenoid type in the Walch classification. RESULTS: Within the arthritic cohort, no statistically significant difference was found between the AP ratio between A and type B glenoids (1.09 ± 0.22 versus 1.03 ± 0.16 p=0.09), between A and D type glenoids (1.09 ± 0.22 versus 1.12 ± 0.27, p=0.77) nor between the A and C type glenoids (1.09 ± 0.22 versus 1.10 ± 0.19, p=1). No correlation was found between AP ratio and glenoid version/humeral subluxation (rho =-0.0360, p=0.55; rho = 0.076; p=0.21). The APdeltoid ratio of type A glenoids was significantly greater than that of type B glenoids (0.48 ± 0.15 versus 0.35 ± 0.16, p< 0.01), and type C glenoids (0.48 ± 0.15 versus 0.21±0.10, p < 0.01) but not significantly different from the APdeltoid ratio of type D glenoids (0.48 ± 0.15 versus 0.64 ± 0.34, p=1). When evaluating both healthy control and arthritic shoulders, moderate correlations were found between APdeltoid ratio and glenoid version/humeral subluxation (rho=0.55, p<0.01; rho=-0.61, p<0.01). CONCLUSION: As opposed to previous two-dimensional CT scan studies, we did not find any correlation between AP muscle volume ratio and glenoid parameters in arthritic shoulders. Therefore, rotator cuff muscle imbalance does not seem to be associated with posterior humeral subluxation leading to posterior glenoid erosion and subsequent retroversion characteristic of Walch B glenoids. However, our results could suggest that a larger posterior deltoid pulls the humerus posteriorly into posterior subluxation, but this requires further evaluation as the deltoid follows the humerus possibly leading to secondary asymmetry between the anterior and the posterior deltoid.

6.
Int Orthop ; 47(2): 299-307, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36574021

RESUMO

PURPOSE: Clinical evaluation of the shoulder range of motion (RoM) may vary significantly depending on the surgeon. We aim to validate an automatic shoulder RoM measurement system associating image acquisition by an RGB-D (red/green/blue-depth) video camera to an artificial intelligence (AI) algorithm. METHODS: Thirty healthy volunteers were included. A 3D RGB-D sensor that simultaneously generated a colour image and a depth map was used. Then, an open-access convolutional neural network algorithm that was programmed for shoulder recognition provided a 3D motion measure. Each volunteer adopted a randomized position successively. For each position, two observers made a visual (EyeREF) and goniometric measurement (GonioREF), blind to the automated software which was implemented by an orthopaedic surgeon. We evaluated the inter-tester intra-class correlation (ICC) between observers and the concordance correlation coefficient (CCC) between the three methods. RESULTS: For manual evaluations EyeREF and GonioREF, ICC remained constantly excellent for the widest motions in the vertical plane (i.e., abduction and flexion). It was very good for ER1 and IR2 and fairly good for adduction, extension, and ER2. Differences between the measurements' means of EyeREF and shoulder RoM was significant for all motions. Compared to GonioREF, shoulder RoM provided similar results for abduction, adduction, and flexion and EyeREF provided similar results for adduction, ER1, and ER2. The three methods showed an overall good to excellent CCC. The mean bias between the three methods remained under 10° and clinically acceptable. CONCLUSION: RGB-D/AI combination is reliable in measuring shoulder RoM in consultation, compared to classic goniometry and visual observation.


Assuntos
Articulação do Ombro , Ombro , Humanos , Inteligência Artificial , Amplitude de Movimento Articular , Encaminhamento e Consulta , Reprodutibilidade dos Testes , Articulação do Ombro/cirurgia , Software
7.
J Shoulder Elbow Surg ; 31(1): 113-122, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34280573

RESUMO

HYPOTHESIS: The purpose was to report the short-term outcomes and survival of hemiarthroplasty with a pyrocarbon head (HA-PYC) for the treatment of shoulder osteoarthritis in patients aged ≤ 60 years. We hypothesized that HA-PYC could be an alternative to hemi-metal (avoiding the risk of rapid glenoid erosion) and total shoulder arthroplasty (TSA) (avoiding the risk of rapid glenoid loosening) in an active patient population. METHODS: Sixty-four consecutive patients (mean age, 53 years) who underwent HA-PYC for glenohumeral osteoarthritis were included. The primary outcome was revision to TSA or reverse shoulder arthroplasty. Secondary outcome measures included functional outcome scores; return to work and sports; and radiographic evaluation of humeral reconstruction quality using the "circle method" of Mears, as well as glenoid erosion severity and progression using the Sperling classification. Patients were reviewed and underwent radiography at an average follow-up of 33 months (range, 24-60 months). RESULTS: At last follow-up, the rate of survival of the HA-PYC prosthesis was 92%. Revision was performed in 5 patients, with a mean delay of 24 months (range, 15-37 months): 1 conversion to TSA and 4 conversions to reverse shoulder arthroplasty. The Constant score and Subjective Shoulder Value increased from 36 points (range, 26-50 points) to 75 points (range, 69-81 points) and from 35% (range, 20%-50%) to 80% (range, 75%-90%), respectively (P < .001). Postoperatively, 91% of the patients (42 of 46) returned to work and 88% (15 of 17) returned to sport. The severity of preoperative and postoperative glenoid wear (Sperling grade 3 or 4) had no influence on the functional results. Patients who underwent associated concentric glenoid reaming (n = 23) had similar Constant scores and Subjective Shoulder Values (P = .95) to other patients and did not show more progression of glenoid wear. Nonanatomic reconstruction of the proximal humerus (center of rotation of the prosthesis > 3 mm from the anatomic center) occurred in 29% (18 of 62 patients) and was associated with significantly lower functional and subjective results, more complications (subscapularis insufficiency and/or symptomatic glenoid erosion), and a higher risk of revision. The additional 1.5-mm thickness of the metal disc under the pyrocarbon head was found to be the main reason for oversizing of the prosthetic head. CONCLUSION: HA-PYC is a reliable procedure to treat shoulder osteoarthritis and allows return to work and sports in a young (≤60 years) and active patient population. The severity of glenoid bone erosion or the association with glenoid reaming does not affect functional outcomes and failure risk. By contrast, nonanatomic reconstruction of the proximal humerus after HA-PYC (because of humeral head oversizing) occurred in one-third of the cases and is associated with lower functional outcomes, as well as higher risks of complications and revision.


Assuntos
Artroplastia do Ombro , Hemiartroplastia , Articulação do Ombro , Prótese de Ombro , Carbono , Seguimentos , Humanos , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Estudos Retrospectivos , Ombro , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Resultado do Tratamento
8.
J Shoulder Elbow Surg ; 31(7): 1515-1523, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35085600

RESUMO

BACKGROUND: Variations in humeral component designs in hemiarthroplasty and anatomic total shoulder arthroplasty cases can impact the degree of difficulty during a revision surgery that necessitates the removal of the humeral stem. However, no metric exists to define stem extraction effort nor to identify associated factors that contribute to extraction difficulty. The purpose of this study is to describe a method to quantify stem extraction difficulty and to define features that will impact the effort during stem removal. METHODS: This was a retrospective review of 58 patients undergoing revision of hemiarthroplasty or anatomic total shoulder arthroplasty requiring stem extraction. Each included patient had existing preoperative radiographic examination, an intraoperative video of the stem removal process, and explants available for analysis by 3 surgeons. The following factors were assessed for the impact on extraction difficulty: (1) preoperative features such as cement use, fill of proximal humerus, and stem design features; (2) intraoperative data on extraction time and bone removal; and (3) postoperative findings related to extraction artifacts (EAs). A scoring system was established to distinguish easy (Easy group) and difficult (Difficult group) stem removal cases and further used to identify the features that may affect intraoperative difficulty of stem removal. RESULTS: The Difficult group accounted for 26% (15/58) of the study population with an 18-minute average stem extraction time, average EA count of 69, and 35 mm of bone removed. The Easy group accounted for 74% (43/58) of patients, with a 4-minute average extraction time, average EA count of 23, and 10 mm of bone removed. Logistic regression model was able to correctly classify 82% of the cases, explaining 26.7% of the variance in humeral stem removal with cement and proximal coating variables. The likelihood of cemented stem removal being difficult is 5 times greater compared to an uncemented stem, and having proximal coating doubles the likelihood of a difficult stem removal compared to cases with no coating. CONCLUSIONS: Quantifying stem extraction difficulty is possible with intraoperative video as well as explant analysis. Preoperative features of the fixation type and specific features of stem design such as proximal coating will impact difficulty of stem extraction.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Artroplastia do Ombro/métodos , Cimentos Ósseos , Humanos , Úmero/diagnóstico por imagem , Úmero/cirurgia , Reoperação/métodos , Estudos Retrospectivos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Resultado do Tratamento
9.
Int Orthop ; 46(11): 2577-2583, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35701591

RESUMO

PURPOSE: There is no consensus on the type of surgical treatment of congenital pseudarthrosis of the clavicle due to its rarity. The purpose of this study is to provide evidence in favor of a surgical technique and to explore factors correlated with bone consolidation. METHODS: Systematic review of the literature and an analysis of the data for each subject, including all available subjects from the published series and clinical cases since 1990. Fisher's exact tests or T-tests were used to evaluate the effect of independent variables (age at surgery and type of treatment) on bone healing. RESULTS: The literature search provides 305 articles; 30 were selected, reporting 191 patients and 194 clavicles. One hundred and fifty-one clavicles were operated on at a mean age of nine years and four months (from 8 months to 21 years). Thirteen clavicles (8, 6%) had not consolidated at the last follow-up. Concerning the type of fixation, the rate of healing was similar for plates and pins (p = 0.27). The rate of consolidation was higher with autograft than with allograft, xenograft, or no graft (p = 0.00001), and was 100% for vascularized graft. The mean age at surgery was higher for patients who healed at the last follow-up (118 vs. 61 months, p = 0.001). CONCLUSION: In the event of surgical indication for congenital pseudarthrosis of the clavicle, it is recommended to perform autograft and stable fixation (level 4) after seven years old (level 4).


Assuntos
Pseudoartrose , Transplante Ósseo/métodos , Criança , Clavícula/cirurgia , Humanos , Pseudoartrose/congênito , Pseudoartrose/cirurgia , Transplante Autólogo
10.
J Shoulder Elbow Surg ; 30(12): 2886-2894, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34175466

RESUMO

BACKGROUND: Several studies have already reported good short-term results with a pyrocarbon unipolar radial head prosthesis (Pyc-uRHP). The aim was to evaluate the evolution from mid- to long-term clinical and radiographic outcomes of a Pyc-uRHP. METHODS: This was a retrospective, single-center study. We followed up all the patients who underwent Pyc-uRHP surgery in our original study at 2 years of follow-up (52 patients), reaching a minimum of 7 years of clinical and radiologic follow-up. This study included 26 patients who underwent a clinical examination assessing mobility, the Mayo Elbow Performance Score, and the visual analog scale score and radiologic evaluation with anteroposterior and profile radiographs at a mean follow-up of 110 months (range, 78-162 months). The radiologic study analyzed signs of proximal osteolysis, stem loosening, capitellar wear, and humeroulnar osteoarthritis. RESULTS: No patients required revision. Eight patients required reoperation: coronoid screw removal in 1 and arthrolysis for stiffness in 7. The mean time to reoperation was 11 months. The mean Mayo Elbow Performance Score at last follow-up was 96 ± 9 (of 100), with a pain score of 42 ± 7 (of 45), mobility score of 19 ± 2 (of 20), stability score of 10 (of 10), and function score of 25 (of 25). Comparison with clinical data from the mid-term delay did not reveal any significant difference. All patients presented with proximal osteolysis around the neck but without progression. No stem loosening was noted. The rates of humeroulnar osteoarthritis (12% at mid-term vs. 80% at last follow-up, P < .0001) and capitellar lesions (34% at mid-term vs. 80% at last follow-up, P = .001) increased significantly. CONCLUSION: We have shown that a Pyc-uRHP at 9 years' follow-up provided stable and satisfactory clinical results. Osteolysis of the radial neck was always present but it did not evolve, and no stem loosening was noted. Finally, we have shown a clear worsening of radiologic humeroulnar osteoarthritis and capitellar lesions that remained asymptomatic.


Assuntos
Articulação do Cotovelo , Prótese de Cotovelo , Fraturas do Rádio , Carbono , Articulação do Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/cirurgia , Seguimentos , Humanos , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento
11.
J Shoulder Elbow Surg ; 30(10): 2270-2282, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33813011

RESUMO

BACKGROUND: An assessment of the pathoanatomic parameters of the arthritic glenohumeral joint (GHJ) has the potential to identify discriminating metrics to differentiate glenoid types in shoulders with primary glenohumeral osteoarthritis (PGHOA). The aim was to identify the morphometric differences and threshold values between glenoid types including normal and arthritic glenoids with the various types in the Walch classification. We hypothesized that there would be clear morphometric discriminators between the various glenoid types and that specific numeric threshold values would allow identification of each glenoid type. METHODS: The computed tomography scans of 707 shoulders were analyzed: 585 obtained from shoulders with PGHOA and 122 from shoulders without glenohumeral pathology. Glenoid morphology was classified according to the Walch classification. All computed tomography scans were imported in a dedicated automatic 3D-software program that referenced measurements to the scapular body plane. Glenoid and humeral modeling was performed using the best-fit sphere method, and the root-mean-square error was calculated. The direction and orientation of the glenoid and humerus described glenohumeral relationships. RESULTS: Among shoulders with PGHOA, 90% of the glenoids and 85% of the humeral heads were directed posteriorly in reference to the scapular body plane. Several discriminatory pathoanatomic parameters were identified: GHJ narrowing < 3 mm was a discriminatory metric for type A glenoids. Posterior humeral subluxation > 70% discriminated type B1 from normal GHJs. The root-mean-square error was a discriminatory metric to distinguish type B2 from type A, type B3, and normal GHJs. Type B3 glenoids differed from type A2 by greater retroversion (>13°) and subluxation (>71%). The type C glenoid retroversion inferior limit was 21°, whereas normal glenoids never presented with retroversion > 16°. CONCLUSION: Pathoanatomic metrics with the identified threshold values can be used to discriminate glenoid types in shoulders with PGHOA.


Assuntos
Osteoartrite , Articulação do Ombro , Benchmarking , Humanos , Cabeça do Úmero , Osteoartrite/diagnóstico por imagem , Escápula/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem
12.
Int Orthop ; 45(10): 2653-2661, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34383105

RESUMO

AIM: To demonstrate how reverse shoulder arthroplasty (RSA) planning software could be used to improve how the trainees position glenoid and humeral implants and obtain optimal simulated range of motion (ROM). METHODS: We selected four groups of five various level participants: medical student (MS), junior resident (JR), senior resident (SR), and shoulder expert (SE). Thereafter, the 20 participants planned five cases of arthritic shoulders for a RSA on a validated planning software following three phases: (1) no guidelines and no ROM feedback, (2) guidelines but no ROM feedback, and (3) guidelines and ROM feedback. We evaluated the final simulated impingement-free ROM, the choice of the implant (baseplate size, graft, glenosphere), and the glenoid implant positioning. RESULTS: MS planning were significantly improved by the ROM feedback only. JR took the best advantage of both guidelines and ROM in final results. SR planning were less performant than SE into phase 1 regarding flexion, external rotation, and adduction (respectively - 10°, p = 0.03; - 11°, p = 0.003; and - 3°, p = 0,03), but reached similar results into phase 3 (respectively - 2°, p = 0.329; - 4°, p = 0.44; - 2°, p = 0.319). For MS, JR, and SR, we observed a systematic improvement in the agreement over the study course. The glenoid diameter remained highly variable even for SE. Comparing glenoid implant position to SE, the distance error decreased with advancing phases. CONCLUSION: Planning software can be used as a simulation training tool to improve implant positioning in shoulder arthroplasty procedures.


Assuntos
Artroplastia do Ombro , Cavidade Glenoide , Articulação do Ombro , Cavidade Glenoide/diagnóstico por imagem , Cavidade Glenoide/cirurgia , Humanos , Amplitude de Movimento Articular , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Software
13.
Int Orthop ; 45(7): 1775-1781, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33893521

RESUMO

PURPOSE: The goal of this study was to assess the clinical outcomes associated with anatomic healing of the greater tuberosity in patients treated for proximal humerus fractures with reverse shoulder arthroplasty. Our hypothesis was that anatomic healing of the greater tuberosity leads to less complications and better functional outcomes. METHODS: RESULTS: Patients from the GT+ group presented better functional outcomes than the GT- group in all evaluated outcomes. Mean constant score was 61 ± 14 versus 56 ± 15, and the subjective shoulder value (SSV) was 77 ± 14 versus 64 ± 21 (p < 0.001). Forward elevation was 128° ± 28° versus 107° ± 30° and external rotation was 23° ± 17° versus 14° ± 17° (p < 0.001). Twenty patients presented with at least one prosthetic dislocation (7 GT+ vs 13 GT-) while nine patients were revised for humeral loosening (1 GT+ vs 8 GT-). The use of a fracture specific humeral stem was associated with a higher rate of greater tuberosity healing. CONCLUSIONS: Non-anatomic healing of the greater tuberosity was associated with a higher dislocation and humeral loosening rate. Anatomic healing of the greater tuberosity lead to better functional outcomes, less humeral-sided complications, and fewer re-operations.


Assuntos
Artroplastia do Ombro , Fraturas do Ombro , Articulação do Ombro , Idoso , Artroplastia do Ombro/efeitos adversos , Humanos , Amplitude de Movimento Articular , Estudos Retrospectivos , Fraturas do Ombro/diagnóstico por imagem , Fraturas do Ombro/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Resultado do Tratamento
14.
J Shoulder Elbow Surg ; 29(8): e306-e312, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32713470

RESUMO

We report a case of a pyrocarbon humeral head resurfacing implant fracture, occurring 6 years after its implantation, without any obvious trauma or dislocation. Initial radiographs showed a proud and oversized pyrocarbon resurfacing implant. On clinical examination, the patient had a painful and pseudoparalyzed shoulder with subscapularis insufficiency. Imaging studies confirmed implant fracture and severe fatty infiltration (Goutallier, grade 4) of the subscapularis muscle. Intraoperatively, the implant was found to be fractured with multiple pyrocarbon debris in the glenohumeral joint. The implant was loose, and gross inspection showed no visible bony adhesion or ongrowth. Histologic analysis showed multiple seats of metallosis in the synovial tissue and cancellous bone of the humeral head. Successful management of this complication was managed with a thorough débridement and irrigation and revision to reverse shoulder arthroplasty. Our observation put into question the use of pyrocarbon as a humeral head resurfacing implant. The material seems to be too fragile to be used as a resurfacing implant and cannot achieve fixation of the implant to bone.


Assuntos
Artroplastia de Substituição/métodos , Carbono , Fraturas Ósseas/cirurgia , Cabeça do Úmero/cirurgia , Articulação do Ombro/cirurgia , Fraturas Ósseas/diagnóstico , Humanos , Cabeça do Úmero/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Radiografia , Articulação do Ombro/diagnóstico por imagem
15.
J Shoulder Elbow Surg ; 29(12): 2446-2458, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33190752

RESUMO

HYPOTHESIS: The aim was to evaluate risk factors for complications, revision, and mid- to long-term outcomes after reverse shoulder arthroplasty (RSA) implanted for proximal humeral fracture sequelae (PHFS). METHODS: The radiographs of 98 patients (mean age, 68 years) who underwent RSA for the treatment of PHFS were reviewed at a minimum 5-year follow-up. PHFS were divided into 4 types according to the Boileau classification: type 1 (46 cases), type 2 (6 cases), type 3 (12 cases), and type 4 (34 cases). The tuberosities underwent osteotomy in 28 cases and excision in 12 (all type 3 or 4 PHFS). The mean follow-up period was 8.4 years (range, 5-14 years). RESULTS: The functional results and rate of RSA survival without revision (85% vs. 100% at 10 years, P = .007) were significantly lower for types 3 and 4 vs. types 1 and 2. Overall, our findings showed that RSA for PHFS is not the panacea that surgeons once believed: At a mean follow-up of 8.5 years (range, 5-14 years), 59% of the patients in our series had fair or poor results. Patients who underwent tuberosity osteotomy or excision had lower functional results (adjusted Constant score, 69% vs. 88%; P < .001), more postoperative complications (32% vs. 9%, P = .003), and a higher revision rate (15% vs. 2%, P = .017). Patients who underwent tuberosity osteotomy or excision at the time of RSA were at risk of postoperative prosthetic instability and humeral stem loosening. The absence of the greater tuberosity at last radiographic follow-up was predictive of higher rates of complications and revisions, as well as a poorer final outcome. Previous fracture fixation was associated with a higher rate of complete tuberosity resorption (56% vs. 33%, P = .026) and with higher rates of postoperative complications (27% vs. 13%, P = .099) and reinterventions (17% vs. 2%, P = .018). CONCLUSION: The functional results and rates of complications and revision depend on the type of fracture sequelae and tuberosity management. Patients with more severe (type 3 and 4) fracture sequelae who undergo tuberosity osteotomy or excision are at risk of having a poorer functional result and higher rates of complications and revision with lower survival. Previous fracture fixation is also a prejudicial factor.


Assuntos
Artroplastia do Ombro , Úmero/cirurgia , Osteotomia/efeitos adversos , Fraturas do Ombro , Articulação do Ombro , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Ombro/efeitos adversos , Artroplastia do Ombro/métodos , Distinções e Prêmios , Europa (Continente) , Feminino , Seguimentos , Humanos , Úmero/diagnóstico por imagem , Úmero/lesões , Masculino , Pessoa de Meia-Idade , Ortopedia , Falha de Prótese , Recuperação de Função Fisiológica , Reoperação , Estudos Retrospectivos , Fatores de Risco , Fraturas do Ombro/classificação , Fraturas do Ombro/complicações , Fraturas do Ombro/diagnóstico por imagem , Fraturas do Ombro/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Sociedades Médicas , Resultado do Tratamento
16.
J Shoulder Elbow Surg ; 29(10): 2111-2122, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32505414

RESUMO

BACKGROUND: Glenoid lateralization has been shown to be the most imortant factor in maximizing passive range of motion and shoulder stability while preventing scapular impingement and notching. We aimed to evaluate mid- to long-term functional and radiologic outcomes after bony increased-offset-reverse shoulder arthroplasty (BIO-RSA) using a Grammont-style (medialized) humeral implant. METHODS: The study included 143 consecutive shoulders (140 patients; mean age, 72 years) treated with a BIO-RSA for rotator cuff deficiency. A cylinder of autologous cancellous bone graft, harvested from the humeral head, was placed between the reamed glenoid surface and baseplate; fixation was achieved using a long central peg (25 mm) and 4 screws. A large baseplate (29 mm) with a small baseplate sphere (36 mm) was used in 77% of cases, and a Grammont-style (medialized) humeral implant with 155° of inclination was used in all cases. All patients underwent clinical and radiographic assessment at a minimum of 5 years after surgery; in addition, 86 cases (60%) underwent computed tomography scan assessment. RESULTS: At a mean follow-up of 75 months (range, 60-126 months), the survivorship of the BIO-RSA using revision as an endpoint was 96%. No cases of dislocation or humeral loosening were observed. Overall, 118 patients (83%) were either very satisfied (61%) or satisfied (22%). The adjusted Constant score improved from 40% ± 18% to 93% ± 23%, and the Subjective Shoulder Value improved from 31% ± 15% to 77% ± 18% (P < .001). The humeral bone graft incorporated completely in 96% of cases (137 of 143). Severe inferior scapular notching (grade 3 or 4) occurred in 18% (24 of 136). The risk of postoperative notching correlated to a lower body mass index (P < .05), superior glenosphere inclination (P = .02), and high or flush glenosphere positioning (P = .035). CONCLUSIONS: BIO-RSA is a safe and effective technique to lateralize the glenoid, providing consistent bone graft healing, excellent functional outcomes, a low revision rate, and a high rate of patient satisfaction. Thin patients (with a low body mass index) and glenosphere malposition (with persistent superior inclination and/or insufficient lowering of the baseplate and sphere) are associated with higher risk of scapular notching.Our data confirm the importance of implanting the baseplate with a neutral inclination (reverse shoulder arthroplasty angle < 5°) and with sufficient glenosphere inferior overhang (>5 mm) in preventing scapular notching. The use of a less medialized humeral implant (135° or 145° inclined) and smaller (25-mm) baseplate (when using a small, 36-mm sphere) should allow reduction in the incidence of scapular notching.


Assuntos
Artroplastia do Ombro/métodos , Transplante Ósseo , Falha de Prótese , Articulação do Ombro/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Ombro/efeitos adversos , Artroplastia do Ombro/instrumentação , Feminino , Seguimentos , Cavidade Glenoide/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Amplitude de Movimento Articular , Reoperação , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Prótese de Ombro/efeitos adversos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
17.
J Shoulder Elbow Surg ; 29(1): e1-e10, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31451348

RESUMO

BACKGROUND: We evaluated survival and midterm results of pyrocarbon interposition shoulder arthroplasty (PISA) in arthritic patients younger than 65 years. METHODS: Fifty-eight PISAs (InSpyre; Tornier-Wright, Bloomington, MN, USA), implanted in 56 patients between 2010 and 2015, were prospectively observed. The mean age at surgery was 52 ± 13 years. The cause was primary osteoarthritis (18), fracture sequelae (16), post-instability arthritis (15), aseptic necrosis (3), inflammatory disease (2), and failed hemiarthroplasty (4); 34 shoulders (61%) had previously undergone surgery. Glenoid erosion was assessed in 4 grades according to the Sperling classification. Humeral erosion was also assessed in 4 grades. Multivariate analysis was used to determine predisposing risk factors for both humeral and glenoid erosion. RESULTS: At a mean follow-up of 47 ± 15 months, survival rate was 90%. Six patients (10%) required conversion to reverse total shoulder prosthesis for painful glenoid erosion (n = 2) and humeral erosion with greater tuberosity stress fractures (n = 4). The mean Constant score and subjective shoulder value significantly increased from 36 ± 14 points to 70 ± 15 points and 32% ± 14% to 75% ± 19%, respectively (P < .001). Humeral medialization was observed in 78% of the cases with increased pain score. Uncorrected anteroposterior implant subluxation (12 cases) was associated with lower Constant score (50 points vs. 72 points; P = .02) and lower subjective shoulder value (53% vs. 78%; P = .002). On multivariate analysis, no risk factors for glenoid or humeral erosion were found. CONCLUSION: At midterm follow-up, PISA does not protect from progressive glenoid erosion and can lead to greater tuberosity erosion and stress fractures. Longer follow-up is required to see whether PISA survival will be superior to that of hemiarthroplasty.


Assuntos
Artroplastia do Ombro/instrumentação , Osteoartrite/cirurgia , Articulação do Ombro/fisiopatologia , Prótese de Ombro , Adulto , Idoso , Artroplastia do Ombro/efeitos adversos , Carbono , Feminino , Seguimentos , Fraturas de Estresse/etiologia , Cavidade Glenoide/diagnóstico por imagem , Humanos , Úmero/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Radiografia , Amplitude de Movimento Articular , Reoperação/instrumentação , Fatores de Risco , Luxação do Ombro/etiologia , Fraturas do Ombro/etiologia , Articulação do Ombro/cirurgia , Prótese de Ombro/efeitos adversos
18.
J Shoulder Elbow Surg ; 29(3): 541-549, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31594726

RESUMO

BACKGROUND: Our aim was to analyze the epidemiology, etiologies, and revision options for failed shoulder arthroplasty from 2 tertiary centers. METHODS: From 1993 to 2013, 542 failed arthroplasties were revised in 540 patients (65% women): 224 hemiarthroplasties (HAs, 41%), 237 anatomic total shoulder arthroplasties (TSAs, 44%) and 81 reverse total arthroplasties (RSAs, 15%). Data about patients, pathology, and reintervention procedures, as well as intraoperative data, were analyzed from our 2 local registries that prospectively captured all the revision procedures. Patients had an average follow-up period of 8.7 years. RESULTS: The revision rate was 12.7% for HAs, 6.7% for TSAs, and 3.9% for RSAs. HAs were revised earlier (33 ± 40 months) than RSAs (47 ± 150 months) and TSAs (69 ± 61 months). Glenoid failure was a major cause of reintervention: erosion in HAs (29%) or loosening in TSAs (37%) and RSAs (24%). Instability was another major cause of reintervention: 32% in RSAs, 20% in TSAs, and 13% in HAs. Humeral implant loosening led to revision in 10% of RSAs, 6% of HAs, and 6% of TSAs. Multiple reinterventions were required in 21% of patients, mainly for instability (26%) and/or infection (25%). The final implant was an RSA in 48%, especially when associated with cuff insufficiency, instability, and/or bone loss. Final reimplantation was possible in 90% of cases, with the remaining 10% treated with a resection or spacer. CONCLUSION: Glenoid failure and instability are the most common causes of revision. Soft-tissue insufficiency and/or infection results in multiple revisions. Surgeons must recognize all complications so that they can be addressed at the first revision operation and avoid further reinterventions. RSA was the most common final revision implant.


Assuntos
Artroplastia do Ombro/efeitos adversos , Hemiartroplastia/efeitos adversos , Artropatias/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Reoperação , Articulação do Ombro/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Artropatias/diagnóstico , Artropatias/cirurgia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/cirurgia , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
19.
J Shoulder Elbow Surg ; 29(12): e468-e477, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32807728

RESUMO

BACKGROUND: Three-dimensional (3D) geometry of the normal glenohumeral bone anatomy and relations is poorly documented. Our aims were (1) to determine the 3D geometry of the normal glenohumeral joint (GHJ) with reference to the scapular body plane and (2) to identify spatial correlations between the orientation and direction of the humeral head and the glenoid. METHODS: Computed tomographies (CTs) of the normal, noninjured GHJ were collected from patients who had undergone CTs in the setting of (1) polytrauma, (2) traumatic head injury, (3) chronic acromioclavicular joint dislocations, and (4) unilateral trauma with a contralateral normal shoulder. We performed 3D segmentation and measurements with a fully automatic software (Glenosys; Imascap). Measurements were made in reference to the scapular body plane and its transverse axis. Geometric measurements included version, inclination, direction, orientation, best-fit sphere radius (BFSR), humeral subluxation, critical shoulder angle, reverse shoulder angle, glenoid area, and glenohumeral distance. Statistical correlations were sought between glenoid and humeral 3D measurements (Pearson correlation). RESULTS: A total of 122 normal GHJs (64 men, 58 women, age: 52 ± 17 years) were studied. The glenoid BFSR was always larger than the humerus BFSR (constant factor of 1.5, standard deviation = 0.2). The mean glenoid version and inclination were -6° ± 4° and 7° ± 5°, respectively. Men and women were found to have significantly different values for inclination (6° vs. 9°, P = .02), but not for version. Humeral subluxation was 59% ± 7%, with a linear correlation with glenoid retroversion (r = -0.70, P < .001) regardless of age. There was a significant and linear correlation between glenoid and humeral orientation and direction (r = 0.72 and r = 0.70, P < .001). CONCLUSION: The 3D geometry of the glenoid and humeral head present distinct limits in normal shoulders that can be set as references in daily practice: version and inclination are -6° and 7°, respectively, and humeral posterior subluxation is 59%; interindividual variations, regardless of the size, are relative to the scapular plane. There exists a strong correlation between the position of the humeral head and the glenoid orientation and direction.


Assuntos
Cavidade Glenoide , Cabeça do Úmero , Escápula , Articulação do Ombro , Adulto , Idoso , Feminino , Cavidade Glenoide/diagnóstico por imagem , Humanos , Cabeça do Úmero/diagnóstico por imagem , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Escápula/diagnóstico por imagem , Articulação do Ombro/anatomia & histologia , Articulação do Ombro/diagnóstico por imagem , Software , Tomografia Computadorizada por Raios X/métodos
20.
J Shoulder Elbow Surg ; 29(5): 931-940, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31982337

RESUMO

BACKGROUND: Scapulothoracic arthrodesis (STA) has been proposed for the treatment of painful scapular winging in patients with facioscapulohumeral muscular dystrophy (FSHD). However, the rate of osseous fusion is variable, and there is a theoretical risk of reduced respiratory function after bilateral STA. METHODS: This was a retrospective study of 10 STAs, performed sequentially, in 5 FSHD patients. The surgical technique involved use of a semitubular plate and wire construct with autograft (iliac crest) interposed between the scapula and rib cage. Osseous fusion, respiratory function, and shoulder function were evaluated. The mean follow-up period was 141 ± 67 months (range, 24-225 months). RESULTS: Early complications included 1 pneumothorax and 1 pleural effusion. No late complications occurred, and no patients underwent reoperation. On postoperative computed tomography images, complete bony union of the scapula to the ribs was observed in 90% of shoulders (9 of 10). Comparison of preoperative and postoperative pulmonary function test results showed no significant difference in vital capacity (from 87% ± 14% to 85% ± 12%) and forced vital capacity (from 86% ± 16% to 77% ± 15%). Patients gained on average 40° of active forward elevation (from 62° ± 20° to 102° ± 4°) and 22° of abduction (from 58° ± 21° to 89° ± 7°) (P < .001). The mean Subjective Shoulder Value increased from 25% ± 8% to 72% ± 18% (P < .001). All patients were pleased with the results and would recommend the procedure to other persons. CONCLUSION: In patients with FSHD, bilateral STA provides satisfactory shoulder function with a high rate of scapulothoracic fusion and few or no significant respiratory repercussions.


Assuntos
Artrodese , Distrofia Muscular Facioescapuloumeral/fisiopatologia , Distrofia Muscular Facioescapuloumeral/cirurgia , Costelas/cirurgia , Escápula/cirurgia , Adolescente , Adulto , Placas Ósseas , Fios Ortopédicos , Criança , Feminino , Seguimentos , Humanos , Ílio/transplante , Osseointegração , Amplitude de Movimento Articular/fisiologia , Testes de Função Respiratória , Estudos Retrospectivos , Articulação do Ombro/fisiopatologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA