AJR Am J Roentgenol ; 210(6): 1208-1215, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29667891

RESUMO

OBJECTIVE: Motion artifact can reduce the diagnostic accuracy of coronary CT angiography (CCTA) for coronary artery disease (CAD). The purpose of this study was to compare the diagnostic performance of an algorithm dedicated to correcting coronary motion artifact with the performance of standard reconstruction methods in a prospective international multicenter study. SUBJECTS AND METHODS: Patients referred for clinically indicated invasive coronary angiography (ICA) for suspected CAD prospectively underwent an investigational CCTA examination free from heart rate-lowering medications before they underwent ICA. Blinded core laboratory interpretations of motion-corrected and standard reconstructions for obstructive CAD (≥ 50% stenosis) were compared with ICA findings. Segments unevaluable owing to artifact were considered obstructive. The primary endpoint was per-subject diagnostic accuracy of the intracycle motion correction algorithm for obstructive CAD found at ICA. RESULTS: Among 230 patients who underwent CCTA with the motion correction algorithm and standard reconstruction, 92 (40.0%) had obstructive CAD on the basis of ICA findings. At a mean heart rate of 68.0 ± 11.7 beats/min, the motion correction algorithm reduced the number of nondiagnostic scans compared with standard reconstruction (20.4% vs 34.8%; p < 0.001). Diagnostic accuracy for obstructive CAD with the motion correction algorithm (62%; 95% CI, 56-68%) was not significantly different from that of standard reconstruction on a per-subject basis (59%; 95% CI, 53-66%; p = 0.28) but was superior on a per-vessel basis: 77% (95% CI, 74-80%) versus 72% (95% CI, 69-75%) (p = 0.02). The motion correction algorithm was superior in subgroups of patients with severely obstructive (≥ 70%) stenosis, heart rate ≥ 70 beats/min, and vessels in the atrioventricular groove. CONCLUSION: The motion correction algorithm studied reduces artifacts and improves diagnostic performance for obstructive CAD on a per-vessel basis and in selected subgroups on a per-subject basis.


Assuntos
Algoritmos , Técnicas de Imagem de Sincronização Cardíaca , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Artefatos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
2.
JACC Cardiovasc Imaging ; 12(7 Pt 2): 1303-1312, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30553687

RESUMO

OBJECTIVES: This study compared the safety and diagnostic yield of a selective referral strategy using coronary computed tomographic angiography (CCTA) compared with a direct referral strategy using invasive coronary angiography (ICA) as the index procedure. BACKGROUND: Among patients presenting with signs and symptoms suggestive of coronary artery disease (CAD), a sizeable proportion who are referred to ICA do not have a significant, obstructive stenosis. METHODS: In a multinational, randomized clinical trial of patients referred to ICA for nonemergent indications, a selective referral strategy was compared with a direct referral strategy. The primary endpoint was noninferiority with a multiplicative margin of 1.33 of composite major adverse cardiovascular events (blindly adjudicated death, myocardial infarction, unstable angina, stroke, urgent and/or emergent coronary revascularization or cardiac hospitalization) at a median follow-up of 1-year. RESULTS: At 22 sites, 823 subjects were randomized to a selective referral and 808 to a direct referral strategy. At 1 year, selective referral met the noninferiority margin of 1.33 (p = 0.026) with a similar event rate between the randomized arms of the trial (4.6% vs. 4.6%; hazard ratio: 0.99; 95% confidence interval: 0.66 to 1.47). Following CCTA, only 23% of the selective referral arm went on to ICA, which was a rate lower than that of the direct referral strategy. Coronary revascularization occurred less often in the selective referral group compared with the direct referral to ICA (13% vs. 18%; p < 0.001). Rates of normal ICA were 24.6% in the selective referral arm compared with 61.1% in the direct referral arm of the trial (p < 0.001). CONCLUSIONS: In stable patients with suspected CAD who are eligible for ICA, the comparable 1-year major adverse cardiovascular events rates following a selective referral and direct referral strategy suggests that both diagnostic approaches are similarly effective. In the selective referral strategy, the reduced use of ICA was associated with a greater diagnostic yield, which supported the usefulness of CCTA as an efficient and accurate method to guide decisions of ICA performance. (Coronary Computed Tomographic Angiography for Selective Cardiac Catheterization [CONSERVE]; NCT01810198).


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Encaminhamento e Consulta , Idoso , Ásia , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/terapia , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , América do Norte , Valor Preditivo dos Testes , Prognóstico , Fatores de Tempo
3.
J Med Imaging (Bellingham) ; 2(1): 016501, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26158090

RESUMO

Deidentification of medical images requires attention to both header information as well as the pixel data itself, in which burned-in text may be present. If the pixel data to be deidentified is stored in a compressed form, traditionally it is decompressed, identifying text is redacted, and if necessary, pixel data are recompressed. Decompression without recompression may result in images of excessive or intractable size. Recompression with an irreversible scheme is undesirable because it may cause additional loss in the diagnostically relevant regions of the images. The irreversible (lossy) JPEG compression scheme works on small blocks of the image independently, hence, redaction can selectively be confined only to those blocks containing identifying text, leaving all other blocks unchanged. An open source implementation of selective redaction and a demonstration of its applicability to multiframe color ultrasound images is described. The process can be applied either to standalone JPEG images or JPEG bit streams encapsulated in other formats, which in the case of medical images, is usually DICOM.

4.
Atherosclerosis ; 237(2): 494-8, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25463080

RESUMO

BACKGROUND: Previous studies have shown that computed tomography coronary angiography (CTA) in patients with suspected coronary artery disease (CAD) predicts short term adverse events. However, there is no current data on whether identifying atherosclerosis on CTA impacts outcomes. We performed a case-control study to assess whether information from CTA can improve outcomes. METHODS: 4244 symptomatic patients (mean age 58 ± 9, 62.5% male) without known CAD who underwent CTA (n = 2538) to rule out CAD were matched to 1706 patients who underwent standard of care in an academic cardiology clinic. Patients were propensity-matched by gender, age, ethnicity, CAD risk factors and follow-up duration. The primary outcome measure was all-cause mortality. Multivariable Cox proportional hazards models incorporated age, gender and traditional risk factors for coronary disease as well as pre-test probability of CAD. RESULTS: There were no significant differences in age, gender, conventional risk factors between groups (p > 0.05). During a mean follow up of 80 ± 11 months, the overall death rate was 6.3% (270 deaths). Death rate was significantly lower in CTA group (n = 106, 4.2%) as compared to the control group (n = 184, 10.8%, p = 0.001). Event free survival was 95.8% and 89.2% in CTA and standard of care groups, respectively. Risk-adjusted hazard ratio of death were 2.5 (95%CI: 1.6-6.7, p = 0.003) in standard of care cohort as compared to CTA group. Multivariate analysis demonstrated that undergoing coronary CTA resulted in a risk reduction of 32%, p = 0.0001. CONCLUSIONS: Improved knowledge of atherosclerosis or increased anti-atherosclerotic therapies among those undergoing CTA may have contributed to improved survival. Our results provide evidence of potential benefit from scanning for atherosclerosis with CTA in symptomatic patients. Large randomized trials are warranted.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico , Tomografia Computadorizada por Raios X , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Cooperação do Paciente , Modelos de Riscos Proporcionais , Estudos Prospectivos , Fatores de Risco , Padrão de Cuidado , Resultado do Tratamento
5.
Am J Cardiol ; 110(3): 337-44, 2012 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-22534053

RESUMO

The American College of Cardiology Appropriate Use Criteria (AUC) were developed to guide use of myocardial perfusion single-photon emission computed tomography (MPS), stress echocardiography, and cardiac computed tomographic angiography (CCTA). To date, cardiologist application of AUC from a patient-based multiprocedure perspective has not been evaluated. A Web-based survey of 15 clinical vignettes spanning a wide spectrum of indications for MPS, STE, and CCTA in coronary artery disease was administered to cardiologists who rated the ordered test as appropriate, inappropriate, or uncertain by AUC application and suggested a preferred alternative imaging procedure, if any. In total 129 cardiologists responded to the survey (mean age 49.5 years, board certification for MPS 65%, echocardiography 39%, CCTA 32%). Cardiologists agreed with published AUC ratings 65% of the time, with differences in all categories (appropriate, 50% vs 53%; inappropriate, 42% vs 20%; uncertain, 9% vs 27%, p <0.0001 for all comparisons). Physician age, practice type, or board certification in MPS or echocardiography had no effect on concordance with AUC ratings, with slightly higher agreement for those board certified in CCTA (68% vs 64%, p = 0.04). Cardiologist procedure preference was positively associated with active clinical interpretation of MPS and CCTA (p = 0.03 for the 2 comparisons) but not for ownership of the respective imaging equipment. In conclusion, cardiologist agreement with published AUC ratings is generally high, although physicians classify more uncertain indications as inappropriate. Active clinical interpretation of a procedure contributes most to increased procedure preference.


Assuntos
Cardiologia , Doença da Artéria Coronariana/diagnóstico , Testes de Função Cardíaca , Padrões de Prática Médica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto
6.
Int J Cardiovasc Imaging ; 26(1): 99-107, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19898955

RESUMO

Helical prospective ECG-gating (pECG) may reduce radiation dose while maintaining the advantages of helical image acquisition for coronary computed tomography angiography (CCTA). Aim of this study was to evaluate helical pECG-gating in CCTA in regards to radiation dose and image quality. 86 patients undergoing 64-multislice CCTA were enrolled. pECG-gating was performed in patients with regular heart rates (HR) < 65 bpm; with the gating window set at 70-85% of the cardiac cycle. All patients received oral and some received additional IV beta-blockers to achieve HR < 65 bpm. In patients with higher or irregular HR, or for functional evaluation, retrospective ECG-gating (rECG) was performed. The average X-ray dose was estimated from the dose length product. Each arterial segment (modified AHA/ACC 17-segment-model) was evaluated on a 4-point image quality scale (4 = excellent; 3 = good, mild artefact; 2 = acceptable, some artefact, 1 = uninterpretable). pECG-gating was applied in 57 patients, rECG-gating in 29 patients. There was no difference in age, gender, body mass index, scan length or tube output settings between both groups. HR in the pECG-group was 54.7 bpm (range, 43-64). The effective radiation dose was significantly lower for patients scanned with pECG-gating with mean 6.9 mSv +/- 1.9 (range, 2.9-10.7) compared to rECG with 16.9 mSv +/- 4.1 (P < 0.001), resulting in a mean dose reduction of 59.2%. For pECG-gating, out of 969 coronary segments, 99.3% were interpretable. Image quality was excellent in 90.2%, good in 7.8%, acceptable in 1.3% and non-interpretable in 0.7% (n = 7 segments). For patients with steady heart rates <65 bpm, helical prospective ECG-gating can significantly lower the radiation dose while maintaining high image quality.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Eletrocardiografia , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada Espiral , Idoso , Doença da Artéria Coronariana/fisiopatologia , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos