Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Am Heart J ; 255: 58-70, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36243111

RESUMO

BACKGROUND: We aimed to assess the diagnostic utility of the Dimension EXL LOCI High-Sensitivity Troponin I (hs-cTnI-EXL) assay. METHODS: This multicenter study included patients with chest discomfort presenting to the emergency department. Diagnoses were centrally and independently adjudicated by two cardiologists using all available clinical information. Adjudication was performed twice including serial measurements of high-sensitivity cardiac troponin (hs-cTn) I-Architect (primary analysis) and serial measurements of hs-cTnT-Elecsys (secondary analysis) in addition to the clinically used (hs)-cTn. The primary objective was to assess and compare the discriminatory performance of hs-cTnI-EXL, hs-cTnI-Architect and hs-cTnT-Elecsys for acute myocardial infarction (MI). Furthermore, we derived and validated a hs-cTnI-EXL-specific 0/1h-algorithm. RESULTS: Adjudicated MI was the diagnosis in 204/1454 (14%) patients. The area under the receiver operating characteristics curve for hs-cTnI-EXL was 0.94 (95%CI, 0.93-0.96), and comparable to hs-cTnI-Architect (0.95; 95%CI, 0.93-0.96) and hs-cTnT-Elecsys (0.93; 95%CI, 0.91-0.95). In the derivation cohort (n = 813), optimal criteria for rule-out of MI were <9ng/L at presentation (if chest pain onset >3h) or <9ng/L and 0h-1h-change <5ng/L, and for rule-in ≥160ng/L at presentation or 0h-1h-change ≥100ng/L. In the validation cohort (n = 345), these cut-offs ruled-out 56% of patients (negative predictive value 99.5% (95%CI, 97.1-99.9), sensitivity 97.8% (95%CI, 88.7-99.6)), and ruled-in 9% (positive predictive value 83.3% (95%CI, 66.4-92.7), specificity 98.3% (95%CI, 96.1-99.3)). Secondary analyses using adjudication based on hs-cTnT measurements confirmed the findings. CONCLUSIONS: The overall performance of the hs-cTnI-EXL was comparable to best-validated hs-cTnT/I assays and an assay-specific 0/1h-algorithm safely rules out and accurately rules in acute MI. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov number, NCT00470587.


Assuntos
Infarto do Miocárdio , Troponina I , Humanos , Estudos Prospectivos , Biomarcadores , Curva ROC , Infarto do Miocárdio/diagnóstico , Troponina T
2.
Respiration ; 102(1): 12-24, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36380628

RESUMO

BACKGROUND: Adequate management is crucial to reduce symptoms, hospitalization, and relapses in patients with asthma. Hospitals often struggle to meet treatment guidelines, and no recent data for Switzerland are available. OBJECTIVES: The aim of the study was to audit the asthma exacerbation management in the Cantonal Hospital of Baselland in order to evaluate the level of compliance with guidelines in a narrative discussion. METHOD: The study design is a retrospective observational cohort study. We evaluated all adult patients presenting to the hospital with a physician-diagnosed asthma exacerbation in 2018 and 2019. The asthma management patients received was compared to the Swiss guidelines and the international GINA guidelines. RESULTS: 160 patients were included (mean age: 50 years old, 57.5% female). SpO2 and heart rate were assessed at presentation in nearly all patients. Peak expiratory flow (PEF) was measured in only 14%. Adequate management of asthma exacerbation with inhaled bronchodilator medication in a combination of short-acting beta-agonists and short-acting anticholinergics was administered to 96% of the patients. Patients with severe symptoms received systemic glucocorticosteroids within 6 h in 55%. At discharge, a reliever medication was prescribed for 64% of the patients and 55% received a new or increased controller therapy with inhaled glucocorticosteroid (ICS). 49% of the patients had no follow-up organized. CONCLUSION: To increase the guideline conformity and quality of asthma exacerbation management, the severity should be better assessed, especially by routinely performing PEF measurements. Treatment needs to be intensified; in particular, the ICS dose should be increased significantly and systemic glucocorticosteroids should be given with a lower threshold.


Assuntos
Antiasmáticos , Asma , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Hospitais Gerais , Estudos Retrospectivos , Asma/tratamento farmacológico , Broncodilatadores/uso terapêutico , Hospitalização , Administração por Inalação , Antiasmáticos/uso terapêutico , Corticosteroides/uso terapêutico
3.
Circulation ; 139(21): 2403-2418, 2019 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-30798615

RESUMO

BACKGROUND: The utility of BNP (B-type natriuretic peptide), NT-proBNP (N-terminal proBNP), and hs-cTn (high-sensitivity cardiac troponin) concentrations for diagnosis and risk-stratification of syncope is incompletely understood. METHODS: We evaluated the diagnostic and prognostic accuracy of BNP, NT-proBNP, hs-cTnT, and hs-cTnI concentrations, alone and against those of clinical assessments, in patients >45-years old presenting with syncope to the emergency department in a prospective diagnostic multicenter study. BNP, NT-proBNP, hs-cTnT and hs-cTnI concentrations were measured in a blinded fashion. Cardiac syncope, as adjudicated by 2 physicians based on all information available including cardiac work-up and 1-year follow-up, was the diagnostic end point. EGSYS (Evaluation of Guidelines in Syncope Study), a syncope-specific diagnostic score, served as the diagnostic comparator. Death and major adverse cardiac events at 30 and 720 days were the prognostic end points. Major adverse cardiac events were defined as death, cardiopulmonary resuscitation, life-threatening arrhythmia, implantation of pacemaker/implantable cardioverter defibrillator, acute myocardial infarction, pulmonary embolism, stroke/transient ischemic attack, intracranial bleeding, or valvular surgery. ROSE (Risk Stratification of Syncope in the Emergency Department), OESIL (Osservatorio Epidemiologico della Sincope nel Lazio), SFSR (San Fransisco Syncope Rule), and CSRS (Canadian Syncope Risk Score) served as the prognostic comparators. RESULTS: Among 1538 patients eligible for diagnostic assessment, cardiac syncope was the adjudicated diagnosis in 234 patients (15.2%). BNP, NT-proBNP, hs-cTnT, and hs-cTnI were significantly higher in cardiac syncope versus other causes (P<0.01). The diagnostic accuracy for cardiac syncope, as quantified by the area under the curve, was 0.77 to 0.78 (95% CI, 0.74-0.81) for all 4 biomarkers, and superior to EGSYS (area under the curve, 0.68 [95%-CI 0.65-0.71], P<0.001). Combining BNP/NT-proBNP with hs-cTnT/hs-cTnI further improved diagnostic accuracy to an area under the curve of 0.81 (P<0.01). BNP, NT-proBNP, hs-cTnT, and hs-cTnI cut-offs, achieving predefined thresholds for sensitivity and specificity (95%), allowed for rule-in or rule-out of ≈30% of all patients. A total of 450 major adverse cardiac events occurred during follow-up. The prognostic accuracy of BNP, NT-proBNP, hs-cTnI, and hs-cTnT for major adverse cardiac events was moderate-to-good (area under the curve, 0.75-0.79), superior to ROSE, OESIL, and SFSR, and inferior to CSRS. CONCLUSIONS: BNP, NT-proBNP, hs-cTnT, and hs-cTnI concentrations provide useful diagnostic and prognostic information in emergency department patients with syncope. CLINICAL TRIAL REGISTRATION: URL: https://www. CLINICALTRIALS: gov. Unique identifier: NCT01548352.

4.
Europace ; 22(12): 1885-1895, 2020 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-33038231

RESUMO

AIMS: The aim of this study is to characterize recurrent syncope, including sex-specific aspects, and its impact on death and major adverse cardiovascular events (MACE). METHODS AND RESULTS: We characterized recurrent syncope in a large international multicentre study, enrolling patients ≥40 years presenting to the emergency department (ED) with a syncopal event within the last 12 h. Syncope aetiology was centrally adjudicated by two independent cardiologists using all information becoming available during syncope work-up and long-term follow-up. Overall, 1790 patients were eligible for this analysis. Incidence of recurrent syncope was 20% [95% confidence interval (CI) 18-22%] within the first 24 months. Patients with an adjudicated final diagnosis of cardiac syncope (hazard ratio (HR) 1.50, 95% CI 1.11-2.01) or syncope with an unknown aetiology even after central adjudication (HR 2.11, 95% CI 1.54-2.89) had an increased risk for syncope recurrence. Least Absolute Shrinkage and Selection Operator regression fit on all patient information available early in the ED identified >3 previous episodes of syncope as the only independent predictor for recurrent syncope (HR 2.13, 95% CI 1.64-2.75). Recurrent syncope carried an increased risk for death (HR 1.87, 95% CI 1.26-2.77) and MACE (HR 2.69, 95% CI 2.02-3.59) over 24 months of follow-up, however, with a time-dependent effect. These findings were confirmed in a sensitivity analysis excluding patients with syncope recurrence or MACE before or during ED evaluation. CONCLUSION: Recurrence rates of syncope are substantial and vary depending on syncope aetiology. Importantly, recurrent syncope carries a time-dependent increased risk for death and MACE. TRIAL REGISTRATION: BAsel Syncope EvaLuation (BASEL IX, ClinicalTrials.gov registry number NCT01548352).


Assuntos
Serviço Hospitalar de Emergência , Síncope , Feminino , Humanos , Incidência , Masculino , Prognóstico , Modelos de Riscos Proporcionais , Síncope/diagnóstico , Síncope/epidemiologia
5.
Circulation ; 137(5): 436-451, 2018 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-29101287

RESUMO

BACKGROUND: The European Society of Cardiology recommends a 0/1-hour algorithm for rapid rule-out and rule-in of non-ST-segment elevation myocardial infarction using high-sensitivity cardiac troponin (hs-cTn) concentrations irrespective of renal function. Because patients with renal dysfunction (RD) frequently present with increased hs-cTn concentrations even in the absence of non-ST-segment elevation myocardial infarction, concern has been raised regarding the performance of the 0/1-hour algorithm in RD. METHODS: In a prospective multicenter diagnostic study enrolling unselected patients presenting with suspected non-ST-segment elevation myocardial infarction to the emergency department, we assessed the diagnostic performance of the European Society of Cardiology 0/1-hour algorithm using hs-cTnT and hs-cTnI in patients with RD, defined as an estimated glomerular filtration rate <60 mL/min/1.73 m2, and compared it to patients with normal renal function. The final diagnosis was centrally adjudicated by 2 independent cardiologists using all available information, including cardiac imaging. Safety was quantified as sensitivity in the rule-out zone, accuracy as the specificity in the rule-in zone, and efficacy as the proportion of the overall cohort assigned to either rule-out or rule-in based on the 0- and 1-hour sample. RESULTS: Among 3254 patients, RD was present in 487 patients (15%). The prevalence of non-ST-segment elevation myocardial infarction was substantially higher in patients with RD compared with patients with normal renal function (31% versus 13%, P<0.001). Using hs-cTnT, patients with RD had comparable sensitivity of rule-out (100.0% [95% confidence interval {CI}, 97.6-100.0] versus 99.2% [95% CI, 97.6-99.8]; P=0.559), lower specificity of rule-in (88.7% [95% CI, 84.8-91.9] versus 96.5% [95% CI, 95.7-97.2]; P<0.001), and lower overall efficacy (51% versus 81%, P<0.001), mainly driven by a much lower percentage of patients eligible for rule-out (18% versus 68%, P<0.001) compared with patients with normal renal function. Using hs-cTnI, patients with RD had comparable sensitivity of rule-out (98.6% [95% CI, 95.0-99.8] versus 98.5% [95% CI, 96.5-99.5]; P=1.0), lower specificity of rule-in (84.4% [95% CI, 79.9-88.3] versus 91.7% [95% CI, 90.5-92.9]; P<0.001), and lower overall efficacy (54% versus 76%, P<0.001; proportion ruled out, 18% versus 58%, P<0.001) compared with patients with normal renal function. CONCLUSIONS: In patients with RD, the safety of the European Society of Cardiology 0/1-hour algorithm is high, but specificity of rule-in and overall efficacy are decreased. Modifications of the rule-in and rule-out thresholds did not improve the safety or overall efficacy of the 0/1-hour algorithm. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT00470587.


Assuntos
Algoritmos , Técnicas de Apoio para a Decisão , Taxa de Filtração Glomerular , Nefropatias/fisiopatologia , Rim/fisiopatologia , Infarto do Miocárdio sem Supradesnível do Segmento ST/sangue , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico , Triagem , Troponina/sangue , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Creatinina/sangue , Europa (Continente)/epidemiologia , Feminino , Humanos , Nefropatias/sangue , Nefropatias/diagnóstico , Nefropatias/epidemiologia , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio sem Supradesnível do Segmento ST/epidemiologia , Valor Preditivo dos Testes , Prevalência , Prognóstico , Estudos Prospectivos , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Fatores de Tempo , Regulação para Cima
6.
Clin Chem ; 65(11): 1426-1436, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31570633

RESUMO

BACKGROUND: We aimed to validate the clinical performance of the high-sensitivity cardiac troponin I [VITROS® Immunodiagnostic Products hs Troponin I (hs-cTnI-VITROS)] assay. METHODS: We enrolled patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction (AMI). Final diagnoses were centrally adjudicated by 2 independent cardiologists considering all clinical information, including cardiac imaging: first, using serial hs-cTnT-Elecsys (primary analysis) and, second, using hs-cTnI-Architect (secondary analysis) measurements in addition to the clinically used (hs)-cTn. hs-cTnI-VITROS was measured at presentation and at 1 h in a blinded fashion. The primary objective was direct comparison of diagnostic accuracy as quantified by the area under the ROC curve (AUC) of hs-cTnI-VITROS vs hs-cTnT-Elecsys and hs-cTnI-Architect, and in a subgroup also hs-cTnI-Centaur and hs-cTnI-Access. Secondary objectives included the derivation and validation of an hs-cTnI-VITROS-0/1-h algorithm. RESULTS: AMI was the adjudicated final diagnosis in 158 of 1231 (13%) patients. At presentation, the AUC for hs-cTnI-VITROS was 0.95 (95% CI, 0.93-0.96); for hs-cTnT-Elecsys, 0.94 (95% CI, 0.92-0.95); and for hs-cTnI-Architect, 0.92 (95% CI, 0.90-0.94). AUCs for hs-cTnI-Centaur and hs-cTnI-Access were 0.95 (95% CI, 0.94-0.97). Applying the derived hs-cTnI-VITROS-0/1-h algorithm (derivation cohort n = 519) to the validation cohort (n = 520), 53% of patients were ruled out [sensitivity, 100% (95% CI, 94.1-100)] and 14% of patients were ruled in [specificity, 95.6% (95% CI, 93.4-97.2)]. Patients ruled out by the 0/1-h algorithm had a survival rate of 99.8% at 30 days. Findings were confirmed in the secondary analyses using the adjudication including serial measurements of hs-cTnI-Architect. CONCLUSIONS: The hs-cTnI-VITROS assay has at least comparable diagnostic accuracy with the currently best validated hs-cTnT and hs-cTnI assays. CLINICALTRIALSGOV IDENTIFIER: NCT00470587.


Assuntos
Bioensaio/métodos , Infarto do Miocárdio/diagnóstico , Troponina I/sangue , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Biomarcadores/sangue , Feminino , Humanos , Limite de Detecção , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/sangue , Estudos Prospectivos , Curva ROC
7.
Clin Chem ; 65(2): 302-312, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30518662

RESUMO

BACKGROUND: The early diagnosis of urgent abdominal pain (UAP) is challenging. Most causes of UAP are associated with extensive inflammation. Therefore, we hypothesized that quantifying inflammation using interleukin-6 and/or procalcitonin would provide incremental value in the emergency diagnosis of UAP. METHODS: This was an investigator-initiated prospective, multicenter diagnostic study enrolling patients presenting to the emergency department (ED) with acute abdominal pain. Clinical judgment of the treating physician regarding the presence of UAP was quantified using a visual analog scale after initial clinical and physician-directed laboratory assessment, and again after imaging. Two independent specialists adjudicated the final diagnosis and the classification as UAP (life-threatening, needing urgent surgery and/or hospitalization for acute medical reasons) using all information including histology and follow-up. Interleukin-6 and procalcitonin were measured blinded in a central laboratory. RESULTS: UAP was adjudicated in 376 of 1038 (36%) patients. Diagnostic accuracy for UAP was higher for interleukin-6 [area under the ROC curve (AUC), 0.80; 95% CI, 0.77-0.82] vs procalcitonin (AUC, 0.65; 95% CI, 0.62-0.68) and clinical judgment (AUC, 0.69; 95% CI, 0.65-0.72; both P < 0.001). Combined assessment of interleukin-6 and clinical judgment increased the AUC at presentation to 0.83 (95% CI, 0.80-0.85) and after imaging to 0.87 (95% CI, 0.84-0.89) and improved the correct identification of patients with and without UAP (net improvement in mean predicted probability: presentation, +19%; after imaging, +15%; P < 0.001). Decision curve analysis documented incremental value across the full range of pretest probabilities. A clinical judgment/interleukin-6 algorithm ruled out UAP with a sensitivity of 97% and ruled in UAP with a specificity of 93%. CONCLUSIONS: Interleukin-6 significantly improves the early diagnosis of UAP in the ED.


Assuntos
Dor Abdominal/diagnóstico , Biomarcadores/sangue , Abdome/diagnóstico por imagem , Adulto , Idoso , Algoritmos , Área Sob a Curva , Serviço Hospitalar de Emergência , Feminino , Humanos , Interleucina-6/sangue , Julgamento , Masculino , Pessoa de Meia-Idade , Pró-Calcitonina/sangue , Estudos Prospectivos , Curva ROC , Tomografia Computadorizada por Raios X
8.
Europace ; 21(3): 511-521, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30137300

RESUMO

AIMS: It is unknown whether cardiac syncope, and possibly also other syncope aetiologies exhibit circadian, weekly, seasonal, and temperature-dependent patterns. METHODS AND RESULTS: We prospectively recorded the exact time, date, and outside temperature of syncope of patients >40 years old presenting with syncope to the emergency department in a diagnostic multicentre study. Two independent cardiologists/emergency physicians adjudicated the final diagnosis based on all information becoming available during clinical work-up including 1-year follow-up. Among 1230 patients, the adjudicated aetiology was cardiac in 14.6%, reflex in 39.2%, orthostatic in 25.7%, other non-cardiac in 9.7%, and unknown in 10.8% of patients. All syncope aetiologies occurred much more frequently during the day when compared with the night (P < 0.01). While reflex and orthostatic syncope showed a broad peak of prevalence with 80.9% of these events occurring between 4 am and 4 pm, cardiac syncope showed a narrow peak of prevalence with 70.1% of all events occurring between 8 am and 2 pm. A weekly pattern was present for most syncope aetiologies, with events occurring mainly from Monday to Friday (P < 0.01). Reflex syncope displayed a seasonal rhythm and was more common in winter (P < 0.01), while cardiac syncope stayed constant over the year. Syncope occurred most often when the outside temperature was coldest. Overall the patterns observed for cardiac syncope were similar to the patterns observed for its differential diagnosis. CONCLUSION: Syncope aetiologies in patients >40 years old display circadian, weekly, seasonal, and temperature-dependent patterns. Unfortunately, these patterns do not allow to reliably differentiate cardiac syncope from other aetiologies.


Assuntos
Ritmo Circadiano , Estações do Ano , Síncope/epidemiologia , Temperatura , Adulto , Idoso , Idoso de 80 Anos ou mais , Austrália/epidemiologia , Europa (Continente)/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nova Zelândia/epidemiologia , Prevalência , Estudos Prospectivos , Fatores de Risco , Síncope/diagnóstico , Síncope/fisiopatologia , Fatores de Tempo , Estados Unidos/epidemiologia
9.
Eur Heart J ; 39(42): 3780-3794, 2018 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-30169752

RESUMO

Aims: We aimed to evaluate the impact of age on the performance of the European Society of Cardiology (ESC) 0/1h-algorithms and to derive and externally validate alternative cut-offs specific to older patients. Methods and results: We prospectively enrolled patients presenting to the emergency department (ED) with symptoms suggestive of acute myocardial infarction in three large diagnostic studies. Final diagnoses were adjudicated by two independent cardiologists. High-sensitivity cardiac troponin (hs-cTn) T and I concentrations were measured at presentation and after 1 h. Patients were stratified according to age [<55 years (young), ≥55 to <70 years (middle-age), ≥70 years (old)]. Rule-out safety of the ESC hs-cTnT 0/1h-algorithm was very high in all age-strata: sensitivity 100% [95% confidence interval (95% CI) 94.9-100] in young, 99.3% (95% CI 96.0-99.9) in middle-age, and 99.3% (95% CI 97.5-99.8) in old patients. Accuracy of rule-in decreased with age: specificity 97.0% (95% CI 95.8-97.9) in young, 96.1% (95% CI 94.5-97.2) in middle-age, and 92.7% (95% CI 90.7-94.3) in older patients. Triage efficacy decreased with increasing age (young 93%, middle-age 80%, old 55%, P < 0.001). Similar results were found for the ESC hs-cTnT 0/1h-algorithm. Alternative, slightly higher cut-off concentrations optimized for older patients maintained very high safety of rule-out, increased specificity of rule-in (P < 0.01), reduced overall efficacy for hs-cTnT (P < 0.01), while maintaining efficacy for hs-cTnI. Findings were confirmed in two validation cohorts (n = 2767). Conclusion: While safety of the ESC 0/1h-algorithms remained very high, increasing age significantly reduced overall efficacy and the accuracy of rule-in. Alternative slightly higher cut-off concentrations may be considered for older patients, particularly if using hs-cTnI. Clinical Trial Registration: https://clinicaltrials.gov/ct2/show/NCT00470587, number NCT00470587 and NCT02355457 (BACC).


Assuntos
Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/epidemiologia , Adulto , Fatores Etários , Idoso , Algoritmos , Diagnóstico Precoce , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto , Estudos Prospectivos , Sensibilidade e Especificidade , Troponina/sangue
10.
Circulation ; 135(17): 1597-1611, 2017 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-28283497

RESUMO

BACKGROUND: Four strategies for very early rule-out of acute myocardial infarction using high-sensitivity cardiac troponin I (hs-cTnI) have been identified. It remains unclear which strategy is most attractive for clinical application. METHODS: We prospectively enrolled unselected patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction. The final diagnosis was adjudicated by 2 independent cardiologists. Hs-cTnI levels were measured at presentation and after 1 hour in a blinded fashion. We directly compared all 4 hs-cTnI-based rule-out strategies: limit of detection (LOD, hs-cTnI<2 ng/L), single cutoff (hs-cTnI<5 ng/L), 1-hour algorithm (hs-cTnI<5 ng/L and 1-hour change<2 ng/L), and the 0/1-hour algorithm recommended in the European Society of Cardiology guideline combining LOD and 1-hour algorithm. RESULTS: Among 2828 enrolled patients, acute myocardial infarction was the final diagnosis in 451 (16%) patients. The LOD approach ruled out 453 patients (16%) with a sensitivity of 100% (95% confidence interval [CI], 99.2%-100%), the single cutoff 1516 patients (54%) with a sensitivity of 97.1% (95% CI, 95.1%-98.3%), the 1-hour algorithm 1459 patients (52%) with a sensitivity of 98.4% (95% CI, 96.8%-99.2%), and the 0/1-hour algorithm 1463 patients (52%) with a sensitivity of 98.4% (95% CI, 96.8%-99.2%). Predefined subgroup analysis in early presenters (≤2 hours) revealed significantly lower sensitivity (94.2%, interaction P=0.03) of the single cutoff, but not the other strategies. Two-year survival was 100% with LOD and 98.1% with the other strategies (P<0.01 for LOD versus each of the other strategies). CONCLUSIONS: All 4 rule-out strategies balance effectiveness and safety equally well. The single cutoff should not be applied in early presenters, whereas the 3 other strategies seem to perform well in this challenging subgroup. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00470587.


Assuntos
Síndrome Coronariana Aguda/diagnóstico , Técnicas de Apoio para a Decisão , Infarto do Miocárdio/diagnóstico , Troponina I/sangue , Síndrome Coronariana Aguda/sangue , Síndrome Coronariana Aguda/mortalidade , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Biomarcadores/sangue , Eletrocardiografia , Europa (Continente) , Feminino , Nível de Saúde , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/sangue , Infarto do Miocárdio/mortalidade , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Regulação para Cima
11.
Clin Chem ; 64(3): 515-525, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29343534

RESUMO

BACKGROUND: There is concern that high-sensitivity cardiac troponin (hs-cTn) may have low diagnostic accuracy in patients with low acute coronary syndrome (ACS) probability. METHODS: We prospectively stratified patients presenting with acute chest discomfort to the emergency department (ED) into 3 groups according to their probability for ACS as assessed by the treating ED physician using a visual analog scale: ≤10%, 11% to 79%, and ≥80%, reviewing all information available at 90 min. hs-cTnT and hs-cTnI concentrations were determined in a blinded fashion. Two independent cardiologists adjudicated the final diagnosis. RESULTS: Among 3828 patients eligible for analysis, 1189 patients had low (≤10%) probability for ACS. The incidence of non-ST-segment elevation myocardial infarction (NSTEMI) increased from 1.3% to 12.2% and 54.8% in patients with low, intermediate, and high ACS probability, respectively. The positive predictive value of hs-cTnT and hs-cTnI was low in patients with low ACS probability and increased with the incidence of NSTEMI, whereas the diagnostic accuracy of hs-cTnT and hs-cTnI for NSTEMI as quantified by the area under the curve (AUC) was very high and comparable among all 3 strata, e.g., AUC hs-cTnI, 0.96 (95% CI, 0.94-0.97); 0.87 (95% CI, 0.85-0.89); and 0.89 (95% CI, 0.87-0.92), respectively. Findings were validated using bootstrap analysis as an alternative methodology to define ACS probability. Similarly, higher hs-cTnT/I concentrations independently predicted all-cause mortality within 2 years (e.g., hs-cTnT hazard ratio, 1.39; 95% CI, 1.27-1.52), irrespective of ACS probability. CONCLUSIONS: Diagnostic and prognostic accuracy and utility of hs-cTnT and hs-cTnI remain high in patients with acute chest discomfort and low ACS probability.ClinicalTrials.gov Identifier: NCT00470587.


Assuntos
Síndrome Coronariana Aguda/diagnóstico , Troponina I/sangue , Troponina T/sangue , Síndrome Coronariana Aguda/sangue , Adulto , Idoso , Biomarcadores/sangue , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/sangue , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/epidemiologia , Probabilidade , Sensibilidade e Especificidade
12.
Clin Chem ; 64(9): 1347-1360, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29941469

RESUMO

BACKGROUND: Clinical performance of the novel high-sensitivity cardiac troponin I (Siemens-hs-cTnI-Centaur) assay is unknown. We aimed to clinically validate the Siemens-hs-cTnI-Centaur assay and develop 0/1-h and 0/2-h algorithms. METHODS: We enrolled patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction (AMI). Final diagnoses were centrally adjudicated by 2 independent cardiologists including all clinical information twice: first, using serial hs-cTnT (Roche-Elecsys, primary analysis); second, using hs-cTnI (Abbott-Architect, secondary analysis) measurements in addition to the clinically applied (hs)-cTn. Siemens-hs-cTnI-Centaur was measured at presentation, 1 h, and 2 h. The primary objective was a direct comparison of diagnostic accuracy, quantified by the area under the ROC curve (AUC), of Siemens-hs-cTnI-Centaur vs the 2 established hs-cTn assays (Roche-hs-cTnT-Elecsys, Abbott-hs-cTnI-Architect). Secondary objectives included the development of Siemens-hs-cTnI-Centaur-specific 0/1-h and 0/2-h algorithms. RESULTS: AMI was the final diagnosis in 318 of 1755 (18%) patients (using Roche-hs-cTnT-Elecsys for adjudication). The AUC at presentation for Siemens-hs-cTnI-Centaur was 0.94 (95% CI, 0.92-0.96) and comparable with 0.95 (95% CI, 0.93-0.97) for Roche-hs-cTnT-Elecsys and 0.93 (95% CI, 0.90-0.96) for Abbott-hs-cTnI-Architect. Applying the derived Siemens-hs-cTnI-Centaur 0/1-h algorithm to the validation cohort, 46% of patients were ruled out (sensitivity, 99.1%; 95% CI, 95.3-100), and 18% of patients were ruled in (specificity, 94.1%; 95% CI, 91.8-95.9). The Siemens-hs-cTnI-Centaur 0/2-h algorithm ruled out 55% of patients (sensitivity, 100%; 95% CI, 94.1-100), and ruled in 18% of patients (specificity, 96.0%; 95% CI, 93.1-97.9). Findings were confirmed in the secondary analyses using serial measurements of Abbott-hs-cTnI-Architect for adjudication. CONCLUSIONS: Diagnostic accuracy and clinical utility of the novel Siemens-hs-cTnI-Centaur assay are high and comparable with the established hs-cTn assays. ClinicalTrials.gov Identifier: NCT00470587.


Assuntos
Infarto do Miocárdio/diagnóstico , Troponina I/sangue , Algoritmos , Dor no Peito , Diagnóstico Precoce , Eletrocardiografia , Feminino , Humanos , Masculino , Infarto do Miocárdio/fisiopatologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Eur J Intern Med ; 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38604939

RESUMO

BACKGROUND: Cognitive impairment (CI) is common among older patients presenting to the emergency department (ED). The failure to recognize CI at ED presentation constitutes a high risk of additional morbidity, mortality, and functional decline. The Clock Drawing Test (CDT) is a well-established cognitive screening test. AIM: In patients presenting to the ED with non-specific complaints (NSCs), we aimed to investigate the usability of the CDT and its prognostic value regarding length of hospital stay (LOS) and mortality. METHOD: Secondary analysis of the Basel Non-specific Complaints (BANC) trial, a prospective delayed type cross-sectional study with a 30-day follow-up. In three EDs, patients presenting with NSCs were enrolled. The CDT was administered at enrollment. RESULTS: In the 1,278 patients enrolled, median age was 81 [74, 87] years and 782 were female (61.19%). A valid CDT was obtained in 737 (57.7%) patients. In patients without a valid CDT median LOS was higher (29 [9, 49] days vs. 22 [9, 45] days), and 30-day mortality was significantly higher than in patients with a valid CDT (n = 45 (8.32%) vs. n = 39 (5.29%)). Of all valid CDTs, 154 clocks (20.9%) were classified as normal, 55 (7.5%) as mildly deficient, 297 (40.3%) as moderately deficient, and 231 (31.3%) as severely deficient. Mortality and LOS increased along with the CDT deficits (p = 0.012 for 30-day mortality; p < 0.001 for LOS). CONCLUSION: The early identification of patients with CI may lead to improved patient management and resource allocation. The CDT could be used as a risk stratification tool for older ED patients presenting with NSCs, as it is a predictor for 30-day mortality and LOS.

14.
Acad Emerg Med ; 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38532263

RESUMO

BACKGROUND: Emergency department (ED) presentations after a ground-level fall (GLF) are common. Falls were suggested to be another possible presenting feature of a myocardial infarction (MI), as unrecognized MIs are common in older adults. Elevated high-sensitivity cardiac troponin (hs-cTn) concentrations could help determine the etiology of a GLF in ED. We investigated the prevalence of both MI and elevated high-sensitivity cardiac troponin T (hs-cTnT) and I (hs-cTnI), as well as the diagnostic accuracy of hs-cTnT and hs-cTnI regarding MI, and their prognostic value in older ED patients presenting after a GLF. METHODS: This was a prospective, international, multicenter, cohort study with a follow-up of up to 1 year. Patients aged 65 years or older presenting to the ED after a GLF were prospectively enrolled. Two outcome assessors independently reviewed all discharge records to ascertain final gold standard diagnoses. Hs-cTnT and hs-cTnI levels were determined from thawed samples for every patient. RESULTS: In total, 558 patients were included. Median (IQR) age was 83 (77-89) years, and 67.7% were female. Elevated hs-cTnT levels were found in 384 (68.8%) patients, and elevated hs-cTnI levels in 86 (15.4%) patients. Three patients (0.5%) were ascertained the gold standard diagnosis MI. Within 30 days, 18 (3.2%) patients had died. Nonsurvivors had higher hs-cTnT and hs-cTnI levels compared with survivors (hs-cTnT 40 [23-85] ng/L in nonsurvivors and 20 [13-33] ng/L in survivors; hs-cTnI 25 [14-54] ng/L in nonsurvivors and 8 [4-16] ng/L in survivors; p < 0.001 for both). CONCLUSIONS: A majority of patients (n = 364, 68.8%) presenting to the ED after a fall had elevated hs-cTnT levels and 86 (15.4%) elevated hs-cTnI levels. However, the incidence of MI in these patients was low (n = 3, 0.5%). Our data do not support the opinion that falls may be a common presenting feature of MI. We discourage routine troponin testing in this population. However, hs-cTnT and hs-cTnI were both found to have prognostic properties for mortality prediction up to 1 year.

15.
Trials ; 25(1): 86, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38273319

RESUMO

BACKGROUND: Lower respiratory tract infections (LRTIs) are among the most frequent infections and a significant contributor to inappropriate antibiotic prescription. Currently, no single diagnostic tool can reliably identify bacterial pneumonia. We thus evaluate a multimodal approach based on a clinical score, lung ultrasound (LUS), and the inflammatory biomarker, procalcitonin (PCT) to guide prescription of antibiotics. LUS outperforms chest X-ray in the identification of pneumonia, while PCT is known to be elevated in bacterial and/or severe infections. We propose a trial to test their synergistic potential in reducing antibiotic prescription while preserving patient safety in emergency departments (ED). METHODS: The PLUS-IS-LESS study is a pragmatic, stepped-wedge cluster-randomized, clinical trial conducted in 10 Swiss EDs. It assesses the PLUS algorithm, which combines a clinical prediction score, LUS, PCT, and a clinical severity score to guide antibiotics among adults with LRTIs, compared with usual care. The co-primary endpoints are the proportion of patients prescribed antibiotics and the proportion of patients with clinical failure by day 28. Secondary endpoints include measurement of change in quality of life, length of hospital stay, antibiotic-related side effects, barriers and facilitators to the implementation of the algorithm, cost-effectiveness of the intervention, and identification of patterns of pneumonia in LUS using machine learning. DISCUSSION: The PLUS algorithm aims to optimize prescription of antibiotics through improved diagnostic performance and maximization of physician adherence, while ensuring safety. It is based on previously validated tests and does therefore not expose participants to unforeseeable risks. Cluster randomization prevents cross-contamination between study groups, as physicians are not exposed to the intervention during or before the control period. The stepped-wedge implementation of the intervention allows effect calculation from both between- and within-cluster comparisons, which enhances statistical power and allows smaller sample size than a parallel cluster design. Moreover, it enables the training of all centers for the intervention, simplifying implementation if the results prove successful. The PLUS algorithm has the potential to improve the identification of LRTIs that would benefit from antibiotics. When scaled, the expected reduction in the proportion of antibiotics prescribed has the potential to not only decrease side effects and costs but also mitigate antibiotic resistance. TRIAL REGISTRATION: This study was registered on July 19, 2022, on the ClinicalTrials.gov registry using reference number: NCT05463406. TRIAL STATUS: Recruitment started on December 5, 2022, and will be completed on November 3, 2024. Current protocol version is version 3.0, dated April 3, 2023.


Assuntos
Pneumonia , Infecções Respiratórias , Adulto , Humanos , Pró-Calcitonina , Qualidade de Vida , Suíça , Infecções Respiratórias/diagnóstico por imagem , Infecções Respiratórias/tratamento farmacológico , Pneumonia/diagnóstico por imagem , Pneumonia/tratamento farmacológico , Pulmão/diagnóstico por imagem , Antibacterianos/efeitos adversos , Ultrassonografia , Serviço Hospitalar de Emergência , Ensaios Clínicos Controlados Aleatórios como Assunto
16.
Eur Heart J Acute Cardiovasc Care ; 11(1): 62-74, 2022 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-34195803

RESUMO

AIMS: To directly compare the diagnostic accuracy of high-sensitivity cardiac troponin (hs-cTn) T vs. hs-cTnI in the early non-invasive differentiation of Type 1 myocardial infarction (T1MI) due to plaque rupture and atherothrombosis from Type 2 myocardial infarction (T2MI) due to supply-demand mismatch. METHODS AND RESULTS: In a prospective multicentre diagnostic study, two independent cardiologists centrally adjudicated the final diagnosis of T1MI vs. T2MI according to the fourth universal definition of myocardial infarction (MI), using all available clinical information including cardiac imaging in patients presenting with acute chest pain. Diagnostic accuracy was quantified by the area under the receiver operating characteristics curve (AUC). The most extensively validated hs-cTnT-Elecsys and hs-cTnI-Architect assays were measured at presentation, 1 h, and 2 h. Among 5887 patients, 1106 (19%) had a final diagnosis of MI, including 860 (78%) T1MI and 246 (22%) T2MI. The AUC of hs-cTnT-Elecsys to differentiate T1MI from T2MI was moderate and comparable to that provided by hs-cTnI-Architect: hs-cTnT-Elecsys AUC-presentation 0.67 [95% confidence interval (CI) 0.64-0.71], AUC-1 h 0.70 (95% CI 0.66-0.74), and AUC-2 h 0.71 (95% CI 0.66-0.75) vs. hs-cTnI-Architect AUC-presentation 0.71 (95% CI 0.67-0.74), AUC-1 h 0.72 (95% CI 0.68-0.76), and AUC-2 h 0.74 (95% CI 0.69-0.78), all P = not significant (NS). Similarly, the AUC of absolute changes was moderate and comparable for hs-cTnT-Elecsys and hs-cTnI-Architect (all P = NS). Cut-off concentrations achieving at least 90% specificity for the differentiation of T1MI vs. T2MI were >114 ng/L for hs-cTnT-Elecsys [odds ratio (OR) 4.2, 95% CI 2.7-6.6] and >371 ng/L for hs-cTnI-Architect (OR 4.0, 95% CI 2.6-6.2). CONCLUSION: hs-cTnT-Elecsys and hs-cTnI-Architect provided comparable, albeit only moderate, diagnostic accuracy for the early differentiation of T1MI vs. T2MI. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov number, NCT00470587, https://clinicaltrials.gov/ct2/show/NCT00470587.


Assuntos
Infarto do Miocárdio , Troponina T , Biomarcadores , Diagnóstico Precoce , Humanos , Infarto do Miocárdio/diagnóstico , Estudos Prospectivos
17.
Heart ; 107(22): 1796-1804, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33504514

RESUMO

OBJECTIVE: To develop an ECG-based tool for rapid risk assessment of a cardiac cause of syncope in patients ≥40 years. METHODS: In a prospective international multicentre study, 2007 patients ≥40 years presenting with syncope were recruited in the emergency department (ED) of participating centres ranging from large university hospitals to smaller rural hospitals in eight countries from May 2010 to July 2017. 12-Lead ECG recordings were obtained at ED presentation following the syncopal event. The primary diagnostic outcome, a cardiac cause of syncope, was centrally adjudicated by two independent cardiologists using all available clinical information including 12-month follow-up. ECG predictors for a cardiac cause of syncope were identified using penalised backward selection and a continuous-scale likelihood was calculated based on regression analysis coefficients. Findings were validated in an independent US multicentre cohort including 2269 patients. RESULTS: In the derivation cohort, a cardiac cause of syncope was adjudicated in 267 patients (16%). Seven ECG criteria were identified as predictors for this outcome: heart rate and QTc-interval (continuous predictors), rhythm, atrioventricular block, ST-segment depression, bundle branch block and ventricular extrasystole/non-sustained ventricular tachycardia (categorical predictors). Diagnostic accuracy of these combined predictors for a cardiac cause of syncope was high (area under the curve 0.80, 95% CI 0.77 to 0.83). Overall, 138 patients (8%) were rapidly triaged towards rule-out and 181 patients (11%) towards rule-in of a cardiac cause of syncope. External validation showed similar performance. CONCLUSION: In patients ≥40 years with a syncopal event, a combination of seven ECG criteria enabled rapid assessment of the likelihood that syncope was due to a cardiac cause. TRIAL REGISTRATION NUMBER: NCT01548352 (BASEL IX), NCT01802398 (SRS study).


Assuntos
Eletrocardiografia/métodos , Frequência Cardíaca/fisiologia , Medição de Risco/métodos , Síncope/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Serviço Hospitalar de Emergência , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Síncope/epidemiologia , Síncope/etiologia , Fatores de Tempo
18.
Eur Heart J Acute Cardiovasc Care ; 9(8): 857-868, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31976746

RESUMO

BACKGROUND: Recent advances in digital electrocardiography technology allow evaluating ST-segment deviations in all 12 leads as quantitative variables and calculating summed ST-segment deviation scores. The diagnostic and prognostic utility of summed ST-segment deviation scores is largely unknown. METHODS: We aimed to explore the diagnostic and prognostic utility of the conventional and the modified ST-segment deviation score (Better Analysis of ST-segment Elevations and Depressions in a 12- Lead-ECG-Score (BASEL-Score): sum of elevations in the augmented voltage right - lead (aVR) plus absolute, unsigned ST-segment depressions in the remaining leads) in patients presenting with suspected non-ST-segment elevation myocardial infarction. The diagnostic endpoint was non-ST-segment elevation myocardial infarction, adjudicated by two independent cardiologists. Prognostic endpoint was mortality during two-year follow up. RESULTS: Among 1330 patients, non-ST-segment elevation myocardial infarction was present in 200 (15%) patients. Diagnostic accuracy for non-ST-segment elevation myocardial infarction as quantified by the area under the receiver-operating-characteristics curve was significantly higher for the BASEL-Score (0.73; 95% confidence interval 0.69-0.77) as compared to the conventional ST-segment deviation score (0.53; 95% confidence interval 0.49-0.57, p<0.001). The BASEL-Score provided additional independent diagnostic value to dichotomous electrocardiogram variables (ST-segment depression, T-inversion, both p<0.001) and to high-sensitivity cardiac troponin (p<0.001) as well as clinical judgment at 90 min (p<0.001). Similarly, only the BASEL-Score proved to be an independent predictor of two year mortality. CONCLUSIONS: The modified ST-segment deviation score BASEL-Score focusing on ST-segment elevation in aVR and ST-segment depressions in the remaining leads provides incremental diagnostic and prognostic information.


Assuntos
Eletrocardiografia , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Idoso , Progressão da Doença , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Curva ROC , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico
19.
West J Emerg Med ; 20(4): 633-640, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31316703

RESUMO

INTRODUCTION: Older patients frequently present to the emergency department (ED) with nonspecific complaints (NSC), such as generalized weakness. They are at risk of adverse outcomes, and early risk stratification is crucial. Triage using Emergency Severity Index (ESI) is reliable and valid, but older patients are prone to undertriage, most often at decision point D. The aim of this study was to assess the predictive power of additional clinical parameters in NSC patients. METHODS: Baseline demographics, vital signs, and deterioration of activity of daily living (ADL) in patients with NSC were prospectively assessed at four EDs. Physicians scored the coherence of history and their first impression. For prediction of 30-day mortality, we combined vital signs at decision point D (heart rate, respiratory rate, oxygen saturation) as "ESI vital," and added "ADL deterioration," "incoherence of history," or "first impression," using logistic regression models. RESULTS: We included 948 patients with a median age of 81 years, 62% of whom were female. The baseline parameters at decision point D (ESI vital) showed an area under the curve (AUC) of 0.64 for predicting 30-day mortality in NSC patients. AUCs increased to 0.67 by adding ADL deterioration to 0.66 by adding incoherence of history, and to 0.71 by adding first impression. Maximal AUC was 0.73, combining all parameters. CONCLUSION: Adding the physicians' first impressions to vital signs at decision point D increases predictive power of 30-day mortality significantly. Therefore, a modified ESI could improve predictive power of triage in older patients presenting with NSCs.


Assuntos
Serviço Hospitalar de Emergência , Mortalidade , Índice de Gravidade de Doença , Triagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estudos Prospectivos , Taxa Respiratória , Fatores Sexuais , Sinais Vitais
20.
Int J Cardiol ; 292: 1-12, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31056411

RESUMO

BACKGROUND: Rapid and reliable diagnosis of ST-elevation myocardial infarction (STEMI) as a surrogate for acute coronary occlusion is critical for early reperfusion therapy. OBJECTIVES: We aimed to examine the diagnostic performance of current guideline-recommended Electrocardiogram (ECG) STEMI criteria. METHODS: In a prospective diagnostic multicenter study, we objectively quantified the extent of ST-segment elevation in all ECG leads using an automated software-based analysis of the digital 12-lead-ECG in adult patients presenting to the emergency department (ED) with suspected myocardial infarction (MI). Classification according to current guideline-recommended ECG criteria for STEMI at ED presentation was compared against a final diagnosis adjudicated by two independent cardiologists after reviewing all available medical records including serial ECGs, cardiac imaging and coronary angiograms. RESULTS: Among 2486 patients, 52 (2%) were found to have significant ST-segment elevation on ECG at ED presentation according to current guideline-recommended ECG criteria for STEMI. Eighty-one (3%) patients received a final adjudicated diagnosis of STEMI. Only 35% (28 of 81) of all patients with a final diagnosis of STEMI were correctly identified (PPV 54% (95% CI 41-66%), sensitivity 35% (95% Cl 24-46%), NPV 97.8% (95% CI 97.5-98.1%). Four reasons for missing STEMIs emerged: timing (significant STE at an earlier/later time point) in 25%, incorrect measurement points in 30%, non or borderline-significant STE in 36% and inferoposterior MI localisation in 9%. CONCLUSIONS: A computerized analysis of current guideline-recommended ECG criteria for STEMI showed suboptimal diagnostic performance when applied to a single 12­lead ECG performed at ED presentation. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00470587.


Assuntos
Eletrocardiografia , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA