Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Arch Gynecol Obstet ; 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38709269

RESUMO

PURPOSE: Evaluate maternal and neonatal outcomes in peripartum coronavirus disease 2019 (COVID-19) positive women. METHODS: A retrospective cohort study was conducted, comparing outcomes between women with and without peripartum COVID-19. All singleton deliveries from June 2020 to January 2022 were included. Univariate analysis was followed by multivariate analysis. RESULTS: Of 26,827 singleton deliveries, 563 women had peripartum COVID-19, associated with preterm deliveries both near-term and remote from term [adjusted odds ratio (aOR) 1.6 and 2.0, respectively, p = 0.007 and 0.003]. Women with peripartum COVID-19 had a significantly higher rate of disseminated intravascular coagulation (DIC) (aOR 23.0, p < 0.001). Conversely, peripartum COVID-19 peripartum COVID-19 was negatively associated with premature rupture of membranes and prolonged maternal length of stay (aOR 0.7 and 0.5, respectively, p = 0.006 and <0.001). In cesarean delivery (CDs), patients with COVID-19 had higher rate of urgent CDs (75.5 vs. 56.1%, p < 0.001), higher rate of regional anesthesia (74.5 vs. 64.9%, p = 0.049), and longer anesthesia duration (86.1 vs. 53.4 min, p < 0.001). CD rate due to non-reassuring fetal heart rate (NRFHR) was significantly higher in women with COVID-19 (29.6 vs. 17.4%, p = 0.002). Conversely, CDs rate due to history of previous single CD was significantly higher in patients without COVID-19 diagnosis (13.6 vs. 4.1%, p = 0.006). Concerning neonatal outcomes, an association has been observed between COVID-19 and low one-minute APGAR score <5, as well as neonatal COVID-19 infection (aOR 61.8 and 1.7 respectively, p < 0.001 and p = 0.037). CONCLUSIONS: Peripartum COVID-19 is associated with preterm deliveries, urgent CDs and DIC, potentially aligning with the infection's pathophysiology and coagulation alterations.

2.
Arch Gynecol Obstet ; 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38225432

RESUMO

PURPOSE: Fetal cardiotocography is the most common method to assess fetal well-being during labor. Nevertheless, its predictive ability for acidemia is limited, both in low-risk and high-risk pregnancies (Nelson et al. in N Engl J Med 334: 613-9, 1996; Rinciples P et al. in Health and Human Development Workshop Report on Electronic Fetal Monitoring : Update on Definitions. no. 2007, 510-515, 2008), especially in high-risk pregnancies, such as those complicated by growth restriction. In this study we aim examine the association between deceleration and acceleration areas and other measure of fetal heart rate in intrapartum fetal monitoring and neonatal arterial cord blood pH in pregnancies complicated by growth restriction. MATERIALS AND METHODS: A retrospective cohort study of 100 deliveries complicated by growth restriction, delivered during 2018, was conducted. Known major fetal anomalies, non-vertex presentation and elective cesarean deliveries were excluded. Total deceleration and acceleration areas were calculated as the sum of the areas within the deceleration and acceleration, respectively. RESULTS: In deliveries complicated by growth restriction, cord blood pH is significantly associated with total deceleration area (p = 0.05) and correlates with cumulative duration of the decelerations (Spearman's rank -0.363, p < 0.05), and total acceleration area (-0.358, p < 0.05). By comparing the cord blood pH in deliveries with a total deceleration area that was above and below the median total deceleration area, we demonstrated a significant difference between the categories. CONCLUSIONS: Cord blood pH significantly correlates with total deceleration area and other fetal monitoring characteristics in neonates with growth restriction. Future studies using real-time, machine-learning based techniques of fetal heart rate monitoring, may provide population specific threshold values that will support bedside clinical decision making and perhaps achieve better outcomes.

3.
Pediatr Res ; 94(3): 1119-1124, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36964444

RESUMO

BACKGROUND: Hypoxic-ischemic encephalopathy (HIE) is an important contributor to disability worldwide. The current cardiotocography (CTG) predictive value for neonatal outcome is limited. OBJECTIVE: To assess the association of intrapartum CTG deceleration and acceleration areas with early MRI cerebral pathology in infants with HIE. METHODS: Term and near-term low-risk pregnancies that resulted in HIE, treated with therapeutic hypothermia with sufficient CTG records from a single, tertiary hospital between 2013 and 2021 were enrolled. Accelerations and decelerations areas, their minimum and maximum depths, and duration were calculated as well as the acceleration-to-deceleration area ratio during the 120 min prior to delivery. These data were assessed for associations with higher degrees of abnormality on early MRI scans. RESULTS: A total of 77 infants were included in the final analysis. Significant associations between increased total acceleration area (p = 0.007) and between a higher acceleration-to-deceleration area ratio (p = 0.003) and better MRI results were detected. CONCLUSION: In neonates treated for HIE, acceleration area and acceleration-to-deceleration ratio are associated with the risk of neonatal brain MRI abnormalities. To increase the role of these measurements as a relevant clinical tool, larger, more powered prospective trials are needed, using computerized real-time analysis. IMPACT: The current cardiotocography predictive value for neonatal outcome is limited. This study aimed to assess the association of intrapartum deceleration and acceleration areas with the degree of cerebral injury in early cerebral MRI of neonates with encephalopathy. Lower acceleration area and acceleration-to-deceleration ratio were found to be associated with a higher degree of neonatal brain injury. Brain MRI is a marker of long-term outcome; its association with cardiotocography indices supports their association with long-term outcome in these neonates. Future computer-based CTG area analysis could assist in delivery room decision making to better time interventions and prevent hypoxic-ischemic encephalopathy.


Assuntos
Lesões Encefálicas , Hipóxia-Isquemia Encefálica , Doenças do Recém-Nascido , Gravidez , Recém-Nascido , Feminino , Humanos , Desaceleração , Estudos Prospectivos , Hipóxia-Isquemia Encefálica/diagnóstico por imagem , Hipóxia-Isquemia Encefálica/terapia , Imageamento por Ressonância Magnética/métodos
4.
Int J Gynaecol Obstet ; 161(3): 1061-1068, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36572017

RESUMO

OBJECTIVE: To investigate whether an association exists between deceleration and acceleration areas on continuous fetal cardiotocography (CTG) and neonatal encephalopathy (NE). METHODS: A single center, retrospective case-control study was conducted to compare CTG characteristics of low-risk pregnancies (35 weeks of gestation or more), complicated by moderate to severe NE with two matched controls for every case. Controls were matched by gestational age and cord blood pH. We analyzed the intrapartum CTG recordings by calculation of the deceleration and acceleration areas and the ratio between the two. RESULTS: During the period between 2013 and 2019, we identified 95 cases of low-risk pregnancies that were complicated by moderate to severe NE in our center. Thirty-three (34.7%) deliveries were excluded, mostly because of an insufficient duration of the CTG recordings. The remaining 62 cases were matched with 123 controls. We found that NE was significantly associated with an increased total deceleration area, a decreased total acceleration area, and a lower acceleration-to-deceleration ratio. CONCLUSIONS: NE was significantly associated with increased total deceleration area, decreased total acceleration area, and a lower acceleration-to-deceleration ratio, independent of cord blood pH. Development of a computerized real-time analysis of fetal heart rate tracings may contribute to making these measurements a more valid clinical tool.


Assuntos
Encefalopatias , Doenças do Recém-Nascido , Gravidez , Recém-Nascido , Feminino , Humanos , Estudos Retrospectivos , Estudos de Casos e Controles , Desaceleração , Cardiotocografia , Frequência Cardíaca Fetal/fisiologia
5.
Int J Gynaecol Obstet ; 159(3): 974-978, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35598120

RESUMO

OBJECTIVE: To assess the correlation between total area under the Curve (AUC) of decelerations and accelerations and neonatal acidemia in pregnancies complicated with meconium-stained amniotic fluid (MSAF). METHODS: A retrospective cohort study was conducted among women who delivered with a diagnosis of MSAF. Electronic fetal monitoring (EFM) patterns 120 min before delivery were interpreted by a researcher blinded to fetal outcomes. The primary outcome was fetal acidemia, defined as umbilical artery pH below 7.10. The correlation was tested using the Spearman correlation coefficient. RESULTS: A total of 102 women were included; 24 delivered infants with cord blood pH < 7.20, and only five delivered infants with cord blood pH < 7.10. A significant correlation was demonstrated between total AUC of decelerations and accelerations and cord blood pH (P = 0.02). A sub-analysis according to gestational age at delivery (up to and beyond 40 weeks) was conducted. A significant correlation was demonstrated (P = 0.02) only in the term group(n = 37). CONCLUSION: A correlation was demonstrated between total AUC of decelerations and accelerations and cord blood pH in neonates with MSAF. This correlation was significant for neonates delivered before 40 weeks of gestation, but not for those delivered after 40 weeks of gestation.


Assuntos
Acidose , Doenças do Recém-Nascido , Complicações na Gravidez , Recém-Nascido , Gravidez , Feminino , Humanos , Sangue Fetal , Mecônio , Líquido Amniótico , Estudos Retrospectivos , Desaceleração , Concentração de Íons de Hidrogênio
6.
J Matern Fetal Neonatal Med ; 33(6): 999-1003, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30231781

RESUMO

Introduction: Instrumental delivery is a well-known risk factor for obstetric anal sphincter injuries (OASIS). The specific characteristics among patient undergoing vacuum extraction delivery (VE) are less studied. Therefore, we aimed to evaluate risk factors for OASIS among parturient that underwent a VE delivery in a large university affiliated maternity hospital.Material and methods: The study population contained 9116 women who delivered by VE in tertiary medical center from 1988 to 2015. Inclusion criteria included deliveries beyond 24-week gestation. Multiple gestations and pregnancies complicated with stillbirth were excluded from the analysis. Maternal obstetric variables were compared between parturient with and without OASIS. Independent risk factors for OASIS were assessed by multivariable logistic regression modeling.Results: OASIS was diagnosed in 94 women (1.03%) following vacuum extraction. Among patients who underwent a VE delivery, gravidity and parity were found to be significantly lower in patients with OASIS. A multivariable logistic regression model with OASIS as the outcome variable revealed that among women who underwent VE, while episiotomy and delivery of a macrosomic neonate were not independently associated with OASIS, a strong association between nulliparity and OASIS was found (OR 3.34; 95% CI 1.93-5.78; p < .001).Conclusions: OASIS is uncommon in our population. Vacuum extraction in nulliparous parturient is a significant risk factor for OASIS. Our results should be taken into account when managing nulliparous deliveries.


Assuntos
Canal Anal/lesões , Complicações do Trabalho de Parto/etiologia , Vácuo-Extração/efeitos adversos , Adulto , Feminino , Maternidades , Hospitais Universitários , Humanos , Modelos Logísticos , Paridade , Gravidez , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA