RESUMO
OBJECTIVES: This study assesses the feasibility of acute type A dissections treatment with a dedicated aortic root endograft concept and introduces a new aortic classification. SUMMARY BACKGROUND DATA: Acute type A aortic dissection (ATAAD) remains a catastrophic aortic condition with perioperative mortality ranging from 12% and 20%. Total Aortic root endovascular repair, "Endobentall concept", has been explored as an alternative but only documented on case report. METHODS: Imaging study of all consecutive patients treated in three French centers were achieved. The study introduces an adapted aortic classification to report entry tear locations. Measurements included aortic annulus mensuration, coronary height, and several aortic lengths. Two treatment concepts were described "fenestrated Endobentall" and "branched Endobentall". Patients were eligible to the "fenestrated endobentall" design if their aortic root dimensions fitted the Edwards Sapien® and Corevalve Medtronic® instruction for use. Eligibility for the "branched Endobentall" required meeting the criteria for a "fenestrated Endobentall" and having a left coronary main stem length exceeding 5 mm. "Branched Endobentall" was mandatory when the entry was located in the aortic root. RESULTS: A total of 250 CT scans for acute type A aortic dissection were reviewed, 116 were finally included for analysis. The primary entry tear was found in the aortic root in 9% of patients, and in 31% of cases, it was located within the first centimeter distal to the sinotubular junction (STJ). 63.7% of the patients were eligible for an Endobentall procedure, even 73.3% when considering extended criterion. Fenestrated Endobentall accounted for 2/3 of cases. CONCLUSION: In our study, 63.7% of patients with aortic type A dissections are deemed eligible to an "Endobentall repair", increasing to 73.3% when considering extended anatomical criteria.
RESUMO
BACKGROUND: No randomized study powered to compare balloon expandable (BE) with self expanding (SE) transcatheter heart valves (THVs) on individual end points after transcatheter aortic valve replacement has been conducted to date. METHODS: From January 2013 to December 2015, the FRANCE-TAVI nationwide registry (Registry of Aortic Valve Bioprostheses Established by Catheter) included 12 141 patients undergoing BE-THV (Edwards, n=8038) or SE-THV (Medtronic, n=4103) for treatment of native aortic stenosis. Long term mortality status was available in all patients (median 20 months; interquartile range, 14 to 30). Patients treated with BE-THV (n=3910) were successfully matched 1:1 with 3910 patients treated with SE-THV by using propensity score (25 clinical, anatomical, and procedural variables) and by date of the procedure (within 3 months). The first coprimary outcome was ≥ moderate occurrence of paravalvular regurgitation or in-hospital mortality, or both. The second coprimary outcome was 2-year all-cause mortality. RESULTS: In propensity-matched analyses, the incidence of the first coprimary outcome was higher with SE-THV (19.8%) compared with BE-THV (11.9%; relative risk, 1.68 [95% CI, 1.46-1.91]; P<0.0001). Each component of the outcome was also higher in patients receiving SE-THV: ≥ moderate paravalvular regurgitation (15.5% versus 8.3%; relative risk, 1.90 [95% CI, 1.63-2.22]; P<0.0001) and in hospital mortality (5.6% versus 4.2%; relative risk, 1.34 [95% CI, 1.07-1.66]; P=0.01). During follow up, all cause mortality occurred in 899 patients treated with SE-THV (2-year mortality, 29.8%) and in 801 patients treated with BE-THV (2-year mortality, 26.6%; hazard ratio, 1.17 [95% CI, 1.06-1.29]; P=0.003). Similar results were found using inverse probability of treatment weighting using propensity score analysis. CONCLUSION: The present study suggests that use of SE-THV was associated with a higher risk of paravalvular regurgitation and higher in-hospital and 2-year mortality compared with use of BE-THV. These data strongly support the need for a randomized trial sufficiently powered to compare the latest generation of SE-THV and BE-THV. CLINICAL TRIAL REGISTRATION: https://www.clinicaltrials.gov. Unique identifier: NCT01777828.
Assuntos
Próteses Valvulares Cardíacas , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Intervalo Livre de Doença , Feminino , Seguimentos , França/epidemiologia , Humanos , Masculino , Taxa de SobrevidaRESUMO
BACKGROUND: The FRANCE-2 registry (French Aortic National Corevalve and Edwards) previously reported good early- and medium-term clinical and echocardiographic efficacy for transcatheter aortic valve replacement. We here report 5-year follow-up results from the registry. METHODS: The registry includes all consecutive patients undergoing transcatheter aortic valve replacement for severe aortic stenosis in France. Follow-up is scheduled at 30 days, 6 months, then annually from 1 to 5 years. Clinical events were defined according to the Valve Academic Research Consortium criteria, and hemodynamic structural valve deterioration (SVD) was defined according to the consensus statement by the European Association of Percutaneous Cardiovascular Interventions. RESULTS: Between January 2010 and January 2012, 4201 patients were enrolled in 34 centers. Five-year vital status was available for 95.5% of patients; 88.1% had clinical evaluation or died. Overall, at 5 years, all-cause mortality was 60.8% (n=2478; 95% CI, 59.3% to 62.3%). The majority of cardiovascular events occurred in the first month after valve implantation, and incidence remained low thereafter, at <2% per year up to 5 years, except for heart failure. The rate of heart failure was 14.3% at 1 year, then decreased over time to <5% per year. In cumulative incidence function, the rates of severe SVD and moderate/severe SVD at 5 years were 2.5% and 13.3%, respectively. Mortality did not differ between patients with or without severe SVD (hazard ratio, 0.71; 95% CI, 0.47-1.07; P=0.1). Finally, in the population of patients with severe SVD, 1 patient (1.7%) experienced a stroke, and 8 patients presented ≥1 heart failure event (13.3%). CONCLUSIONS: The 5-year follow-up results of the FRANCE-2 registry represent the largest long-term data set available in a high-risk population. In surviving patients, the low rate of clinical events and the low level of SVD after 1 year support the long-term efficacy of transcatheter aortic valve replacement in both types of transcatheter prosthesis featuring in the registry.
Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Falha de Equipamento , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Hemodinâmica , Humanos , Masculino , Modelos de Riscos Proporcionais , Sistema de Registros , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Análise de Sobrevida , Fatores de Tempo , Resultado do TratamentoRESUMO
The original version of this article, published on 19 March 2018, unfortunately contained a mistake. The following correction has therefore been made in the original: The names of the authors Philipp A. Kaufmann, Ronny Ralf Buechel and Bernhard A. Herzog were presented incorrectly.
RESUMO
OBJECTIVES: To analyse the implementation, applicability and accuracy of the pretest probability calculation provided by NICE clinical guideline 95 for decision making about imaging in patients with chest pain of recent onset. METHODS: The definitions for pretest probability calculation in the original Duke clinical score and the NICE guideline were compared. We also calculated the agreement and disagreement in pretest probability and the resulting imaging and management groups based on individual patient data from the Collaborative Meta-Analysis of Cardiac CT (CoMe-CCT). RESULTS: 4,673 individual patient data from the CoMe-CCT Consortium were analysed. Major differences in definitions in the Duke clinical score and NICE guideline were found for the predictors age and number of risk factors. Pretest probability calculation using guideline criteria was only possible for 30.8 % (1,439/4,673) of patients despite availability of all required data due to ambiguity in guideline definitions for risk factors and age groups. Agreement regarding patient management groups was found in only 70 % (366/523) of patients in whom pretest probability calculation was possible according to both models. CONCLUSIONS: Our results suggest that pretest probability calculation for clinical decision making about cardiac imaging as implemented in the NICE clinical guideline for patients has relevant limitations. KEY POINTS: ⢠Duke clinical score is not implemented correctly in NICE guideline 95. ⢠Pretest probability assessment in NICE guideline 95 is impossible for most patients. ⢠Improved clinical decision making requires accurate pretest probability calculation. ⢠These refinements are essential for appropriate use of cardiac CT.
Assuntos
Técnicas de Imagem Cardíaca , Dor no Peito/diagnóstico por imagem , Tomada de Decisão Clínica , Fidelidade a Diretrizes , Guias de Prática Clínica como Assunto , Tomografia Computadorizada por Raios X , Adulto , Idoso , Dor no Peito/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Probabilidade , Fatores de RiscoRESUMO
BACKGROUND: Experimental studies suggest that morphine may protect the myocardium against ischemia-reperfusion injury by activating salvage kinase pathways. The objective of this two-center, randomized, double-blind, controlled trial was to assess potential cardioprotective effects of intra-coronary morphine in patients with ST-segment elevation myocardial infarction (STEMI) referred for primary percutaneous intervention. METHODS: Ninety-one patients with STEMI were randomly assigned to intracoronary morphine (1 mg) or placebo at reperfusion of the culprit coronary artery. The primary endpoint was infarct size/left ventricular mass ratio assessed by magnetic resonance imaging on day 3-5. Secondary endpoints included the areas under the curve (AUC) for troponin T and creatine kinase over three days, left ventricular ejection fraction assessed by echocardiography on days 1 and 6, and clinical outcomes. RESULTS: Infarct size/left ventricular mass ratio was not significantly reduced by intracoronary morphine compared to placebo (27.2% ± 15.0% vs. 30.5% ± 10.6%, respectively, p = 0.28). Troponin T and creatine kinase AUCs were similar in the two groups. Morphine did not improve left ventricular ejection fraction on day 1 (49.7 ± 10.3% vs. 49.3 ± 9.3% with placebo, p = 0.84) or day 6 (48.5 ± 10.2% vs. 49.0 ± 8.5% with placebo, p = 0.86). The number of major adverse cardiac events, including stent thrombosis, during the one-year follow-up was similar in the two groups. CONCLUSIONS: Intracoronary morphine at reperfusion did not significantly reduce infarct size or improve left ventricular systolic function in patients with STEMI. Presence of comorbidities in some patients may contribute to explain these results. TRIAL REGISTRATION: ClinicalTrials.gov, NCT01186445 (date of registration: August 23, 2010).
Assuntos
Morfina/administração & dosagem , Intervenção Coronária Percutânea , Substâncias Protetoras/administração & dosagem , Idoso , Método Duplo-Cego , Feminino , França , Humanos , Injeções Intra-Arteriais , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Morfina/efeitos adversos , Traumatismo por Reperfusão Miocárdica/diagnóstico por imagem , Traumatismo por Reperfusão Miocárdica/etiologia , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Miocárdio/patologia , Intervenção Coronária Percutânea/efeitos adversos , Substâncias Protetoras/efeitos adversos , Recuperação de Função Fisiológica , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Volume Sistólico/efeitos dos fármacos , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda/efeitos dos fármacosRESUMO
PURPOSE: To assess the feasibility of exercise perfusion computed tomography (CT) in patients suspected of having hemodynamically significant coronary stenosis. MATERIALS AND METHODS: This study had institutional review board approval, and all patients gave informed consent. Thirty-two consecutive patients (26 men [mean age, 63 years] and six women [mean age, 71 years]) with 55 coronary stenoses of at least 50% underwent coronary CT angiography (one stenosis in 13 patients, two stenoses in 15 patients, and three stenoses in four patients). CT myocardial perfusion imaging was performed within 1 minute after patients performed supine exercise on an ergometer secured to the CT table. The pressure-rate product was computed to assess level of exercise. The myocardial enhancement ratio between stenotic and normally perfused territories was determined for each stenosis. Fractional flow reserve less than 0.8, as measured during invasive coronary angiography, was the reference for defining significant stenoses. Receiver operating characteristic curves were constructed to determine the myocardial enhancement ratio cutoff value. RESULTS: In the per-patient analysis, a myocardial enhancement ratio cutoff of 0.8 performed best for identifying functionally significant stenosis: Sensitivity was 95% (21 of 22 patients), specificity was 90% (nine of 10 patients), positive predictive value was 95% (21 of 22 patients), negative predictive value was 90% (nine of 10 patients), and accuracy was 94% (30 of 32 patients). Corresponding values in the per-stenosis analysis were 97% (29 of 30 stenoses), 96% (23 of 24 stenoses), 97% (29 of 30 stenoses), 96% (23 of 24 stenoses), and 96% (52 of 54 stenoses), respectively. CONCLUSION: Exercise CT myocardial perfusion imaging is feasible and accurate for assessment of the functional significance of coronary stenosis.
Assuntos
Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Teste de Esforço/métodos , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos ProspectivosRESUMO
AIMS: As transcatheter mitral valve (MV) interventions are expanding and more device types and sizes become available, a tool supporting operators in pre-procedural planning and the clinical decision-making process is highly desirable. We sought to develop a finite element computational simulation model to predict the results of transcatheter edge-to-edge repair (TEER) interventions. METHODS AND RESULTS: We prospectively enrolled patients with secondary mitral regurgitation (MR) referred for a clinically indicated TEER. The 3D trans-oesophageal echocardiograms performed at the beginning of the procedure were used to perform the simulation. On the 3D dynamic model of the MV that was first obtained, we simulated the clip implantation using the same clip type, size, number, and implantation location that was used during the intervention. The 3D model of the MV obtained after the simulation of the clip implantation was compared with the clinical results obtained at the end of the intervention. We analysed the degree and location of residual MR and the shape and area of the diastolic MV area. We performed computational simulation on five patients. Overall, the simulated models predicted well the degree and location of the residual regurgitant orifice(s) but tended to underestimate the diastolic mitral orifice area. CONCLUSION: In this proof-of-concept study, we present preliminary results on our algorithm simulating clip implantation in five patients with functional MR. We show promising results regarding the feasibility and accuracy in terms of predicting residual MR and the need to improve the estimation of the diastolic MV area.
Assuntos
Cateterismo Cardíaco , Simulação por Computador , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Insuficiência da Valva Mitral , Estudo de Prova de Conceito , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Feminino , Masculino , Estudos Prospectivos , Idoso , Cateterismo Cardíaco/métodos , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgiaRESUMO
AIM: To determine the effectiveness of functional stress testing and computed tomography angiography (CTA) for diagnosis of obstructive coronary artery disease (CAD). METHODS AND RESULTS: Two-thousand nine-hundred twenty symptomatic stable chest pain patients were included in the international Collaborative Meta-Analysis of Cardiac CT consortium to compare CTA with exercise electrocardiography (exercise-ECG) and single-photon emission computed tomography (SPECT) for diagnosis of CAD defined as ≥ 50% diameter stenosis by invasive coronary angiography (ICA) as reference standard. Generalised linear mixed models were used for calculating the diagnostic accuracy of each diagnostic test including non-diagnostic results as dependent variables in a logistic regression model with random intercepts and slopes. Covariates were the reference standard ICA, the type of diagnostic method, and their interactions. CTA showed significantly better diagnostic performance (p < 0.0001) with a sensitivity of 94.6% (95% CI 92.7-96) and a specificity of 76.3% (72.2-80) compared to exercise-ECG with 54.9% (47.9-61.7) and 60.9% (53.4-66.3), SPECT with 72.9% (65-79.6) and 44.9% (36.8-53.4), respectively. The positive predictive value of CTA was ≥ 50% in patients with a clinical pretest probability of 10% or more while this was the case for ECG and SPECT at pretest probabilities of ≥ 40 and 28%. CTA reliably excluded obstructive CAD with a post-test probability of below 15% in patients with a pretest probability of up to 74%. CONCLUSION: In patients with stable chest pain, CTA is more effective than functional testing for the diagnosis as well as for reliable exclusion of obstructive CAD. CTA should become widely adopted in patients with intermediate pretest probability. SYSTEMATIC REVIEW REGISTRATION: PROSPERO Database for Systematic Reviews-CRD42012002780. CRITICAL RELEVANCE STATEMENT: In symptomatic stable chest pain patients, coronary CTA is more effective than functional testing for diagnosis and reliable exclusion of obstructive CAD in intermediate pretest probability of CAD. KEY POINTS: Coronary computed tomography angiography showed significantly better diagnostic performance (p < 0.0001) for diagnosis of coronary artery disease compared to exercise-ECG and SPECT. The positive predictive value of coronary computed tomography angiography was ≥ 50% in patients with a clinical pretest probability of at least 10%, for ECG ≥ 40%, and for SPECT 28%. Coronary computed tomography angiography reliably excluded obstructive coronary artery disease with a post-test probability of below 15% in patients with a pretest probability of up to 74%.
RESUMO
BACKGROUND: Randomized trials comparing the first-generation absorb bioresorbable vascular scaffold (BVS) (Abbott Vascular, Santa Clara, CA, USA) with a drug-eluting stent showed a moderate but significant increase in the rate of 3-year major adverse cardiac events and scaffold thrombosis, followed by a decrease in adverse events after 3 years. AIM: The objective of this study was to assess the 5-year outcomes of patients treated with at least one absorb BVS and included in the FRANCE ABSORB registry. METHODS: All patients treated in France with an absorb BVS were prospectively included in a large nationwide multicentre registry. The primary efficacy outcome was the occurrence of 5-year major adverse cardiac events. Secondary efficacy outcomes were the rates of 5-year target vessel revascularization and definite/probable scaffold thrombosis. RESULTS: Between September 2014 and April 2016, 2,070 patients were included in 86 centres (mean age 55±11 years; 80% men; 49% with acute coronary syndrome). The rates of 1-, 3- and 5-year major adverse cardiac events were 3.9%, 9.4% and 12.1%, respectively (including cardiac death in 2.5% and target vessel revascularization in 10.4%). By multivariable analysis, diabetes, oral anticoagulation, the use of multiple Absorb BVSs and the use of a 2.5mm diameter absorb BVS were associated with 5-year major adverse cardiac events. The rates of 1-, 3- and 5-year definite/probable scaffold thrombosis were 1.5%, 3.1% and 3.6%, respectively. By multivariable analysis, older age, diabetes, anticoagulation at discharge and the use of a 2.5mm diameter absorb BVS were associated with 5-year scaffold thrombosis. CONCLUSIONS: Absorb BVS implantation was associated with low rates of 1-year major adverse cardiac events, which increased significantly at 3-year follow-up. There was a clear decrease in the rates of scaffold thrombosis and major adverse cardiac events after 3 years.
Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Implantes Absorvíveis , Everolimo , Resultado do Tratamento , Desenho de Prótese , Fatores de Tempo , Sistema de Registros , Anticoagulantes , Intervenção Coronária Percutânea/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgiaRESUMO
Three-dimensionally (3D) printed models have been increasingly used in medicine. Few reports have focused on prototype experiments, especially in aortic surgery. Although endovascular repairs are routinely performed for thoracoabdominal aortic aneurysms and lesions involving the aortic arch, endovascular treatment of the ascending aorta is still at an early stage of development. Using a 3D model, based on patient computed tomography scans and manufactured by Biomodex (Paris, France), we performed a patient-specific rehearsal of an endovascular Bentall repair to treat an ascending aorta aneurysm involving the aortic root. We achieved a patient-specific proof of concept of a new technique using an in vitro 3D model.
RESUMO
OBJECTIVES: Using French transcatheter aortic valve replacement (TAVR) registries linked with the nationwide administrative databases, the study compared the rates of long-term mortality, bleeding, and ischemic events after TAVR in patients requiring oral anticoagulation with direct oral anticoagulants (DOACs) or vitamin K antagonists (VKAs). BACKGROUND: The choice of optimal drug for anticoagulation after TAVR remains debated. METHODS: Data from the France-TAVI and FRANCE-2 registries were linked to the French national health single-payer claims database, from 2010 to 2017. Propensity score matching was used to reduce treatment-selection bias. Two primary endpoints were death from any cause (efficacy) and major bleeding (safety). RESULTS: A total of 24,581 patients who underwent TAVR were included and 8,962 (36.4%) were treated with OAC. Among anticoagulated patients, 2,180 (24.3%) were on DOACs. After propensity matching, at 3 years, mortality (hazard ratio [HR]: 1.37; 95% confidence interval [CI]: 1.12-1.67; P < 0.005) and major bleeding including hemorrhagic stroke (HR: 1.64; 95% CI: 1.17-2.29; P < 0.005) were lower in patients on DOACs compared with those on VKAs. The rates of ischemic stroke (HR: 1.32; 95% CI: 0.81-2.15; P = 0.27) and acute coronary syndrome (HR: 1.17; 95% CI: 0.68-1.99; P = 0.57) did not differ among groups. CONCLUSIONS: In these large multicenter French TAVR registries with an exhaustive clinical follow-up, the long-term mortality and major bleeding were lower with DOACs than VKAs at discharge. The present study supports preferential use of DOACs rather than VKAs in patients requiring oral anticoagulation therapy after TAVR.
Assuntos
Fibrilação Atrial , Substituição da Valva Aórtica Transcateter , Administração Oral , Anticoagulantes/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Vitamina KRESUMO
OBJECTIVES: We aimed to assess the efficiency of a long hydrophilic sheath in reducing radial spasm for transradial approach. BACKGROUND: Despite a lower access site complication rate, cardiac catheterization using transradial approach is not widely used. Radial spasm is one of the main issues for transradial angiography and percutaneous interventions. We assumed that radial artery protection using a long hydrophilic-coated sheath would reduce radial spasm compared to a bare short sheath. METHODS: Three hundred and fifty one patients (pts) admitted for transradial coronary angiography ± percutaneous coronary interventions were randomly assigned to a long hydrophilic-coated or a short sheath (control group). Primary end point was the occurrence of a radial spasm defined by significant patient pain evaluated by scale score (>4) or significant catheter frictions during manipulation. Procedure failure, radial occlusion, and local complications were also assessed. RESULTS: Radial spasm was significantly reduced when using the long-coated compared to the short sheath in 7 (4%) vs. 32 pts (18%) P < 0.001. No difference was found regarding procedure failure respectively 1.2% vs. 0.6%, local complication 0.6% vs. 1.2%, and radial occlusion 3.5% vs. 3.5%. CONCLUSION: Radial artery protection using the long hydrophilic-coated sheath was efficient in the prevention of radial spasm for transradial approach. © 2010 Wiley-Liss, Inc.
Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Arteriopatias Oclusivas/prevenção & controle , Cateterismo Cardíaco/efeitos adversos , Angiografia Coronária/efeitos adversos , Artéria Radial , Espasmo/prevenção & controle , Idoso , Angioplastia Coronária com Balão/instrumentação , Arteriopatias Oclusivas/etiologia , Cateterismo Cardíaco/instrumentação , Distribuição de Qui-Quadrado , Angiografia Coronária/instrumentação , Desenho de Equipamento , Feminino , França , Fricção , Humanos , Masculino , Pessoa de Meia-Idade , Dor/etiologia , Dor/prevenção & controle , Medição da Dor , Punções , Medição de Risco , Fatores de Risco , Espasmo/etiologiaRESUMO
AIMS: No randomised study comparing the outcomes of transcarotid (TC) and transaxillary (TAx) TAVR has been conducted to date. The purpose of this study was to understand which approach should be the preferred alternative by comparing their outcomes using a propensity-matched comparison in a French multicentre registry. METHODS AND RESULTS: From 2010 to 2018, a French multicentre prospective registry included 502 patients, with 374 undergoing TC-TAVR and 128 TAx-TAVR for symptomatic aortic stenosis. Patients treated through TAx access were matched 1:2 with patients treated through the TC route by using a propensity score (20 clinical, anatomical and procedural variables) and by date of the procedure. The first outcome was mortality at one-month follow-up. The second outcome was one-month stroke/transient ischaemic attack (TIA). In propensity-matched analyses, the incidence of the primary outcome was similar in the TAx and TC groups (TAx 5.5% vs TC 4.5%, OR 1.23, 95% CI: 0.40-3.70). The secondary outcome was similar in TAx (3.2%) and TC (6.8%, OR 0.52, 95% CI: 0.14-1.84). Minor bleeding (2.7% vs 9.3%, OR 0.26, 95% CI: 0.07-0.92) and main access haematoma (3.6% vs 10.3%, OR 0.034, 95% CI: 0.09-0.92) were significantly more frequent with the TC access. One-month clinical efficacy and safety and one-year mortality did not differ according to the different routes. CONCLUSIONS: One-month mortality, one-month stroke/TIA and one-year mortality are similar with TAx-TAVR and TC-TAVR. However, TC-TAVR is accompanied by more minor bleeding and main access haematoma compared with the transaxillary route.
Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
AIMS: We evaluated the accuracy of 64-slice computed tomography (CT) to identify ischaemic aetiology of heart failure (IHF). METHODS AND RESULTS: Ninety-three consecutive patients in sinus rhythm with dilated cardiomyopathy but without suspicion of coronary artery disease (CAD) were enrolled when admitted for angiography. Accuracy of CT to detect significant stenosis (>50% lumen narrowing) was compared with quantitative coronary angiography. IHF was defined as a significant stenosis on left main or proximal left anterior descending artery or two or more vessels. Forty-three out of 1395 segments (3%) were heavily calcified and excluded. CT correctly assessed 103 of 142 (73%) significant stenosis and identified 46 of 50 (92%) patients without and 42 of 43 (98%) patients with CAD, 60 of 62 (97%) patients without and 28 of 31 (90%) patients with IHF. Overall, accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of CT for identifying CAD by segment was 96, 73, 99, 92, and 97%, respectively; by patient was 95, 98, 92, 91, and 98%, respectively; and for identifying IHF was 95, 90, 97, 93, and 95%, respectively. CONCLUSION: Non-invasive 64-slice CT assessment of the extent of CAD may offer a valid alternative to angiography for the diagnosis of IHF.
Assuntos
Estenose Coronária/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Calcinose/diagnóstico por imagem , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/etiologia , Angiografia Coronária/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e EspecificidadeRESUMO
BACKGROUND: Several randomized studies have shown that bioresorbable vascular scaffold (BVS) technology is associated with an increased risk of stent thrombosis. AIM: This study aimed to assess the rates of adverse outcomes at 1 year in patients treated with the Absorb BVS (Abbott Vascular, Santa Clara, CA, USA), using data from a large nationwide prospective multicentre registry (FRANCE ABSORB). METHODS: All patients receiving the Absorb BVS in France were included prospectively in the study. Predilatation, optimal sizing and postdilatation were recommended systematically. The primary endpoint was a composite of cardiovascular death, myocardial infarction and target lesion revascularization at 1 year. Secondary endpoints were scaffold thrombosis and target vessel revascularization at 1 year. RESULTS: A total of 2072 patients at 86 centres were included: mean age 55±11 years; 80% men. The indication was acute coronary syndrome (ACS) in 49% of cases. Predilatation and postdilatation were done in 93% and 83% of lesions, respectively. At 1 year, the primary endpoint occurred in 3.9% of patients, the rate of scaffold thrombosis was 1.5% and the rate of target vessel revascularization was 3.3%. In a multivariable analysis, diabetes and total Absorb BVS length>30mm were independently associated with the occurrence of the primary endpoint, whereas oral anticoagulation and total Absorb BVS length>30mm were independently associated with occurrence of scaffold thrombosis. CONCLUSIONS: The Absorb BVS was implanted in a relatively young population, half of whom had ACS. Predilatation and postdilatation rates were high, and 1-year outcomes were acceptable.
Assuntos
Implantes Absorvíveis , Síndrome Coronariana Aguda/cirurgia , Angina Instável/cirurgia , Angioplastia Coronária com Balão/instrumentação , Infarto do Miocárdio/cirurgia , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Adulto , Idoso , Angina Instável/diagnóstico por imagem , Angina Instável/mortalidade , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Trombose Coronária/etiologia , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/mortalidade , Estudos Prospectivos , Desenho de Prótese , Recidiva , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
OBJECTIVES: This study sought to describe the procedural and clinical outcomes of patients undergoing transcarotid (TC) transcatheter aortic valve replacement (TAVR) with the Edwards Sapien 3 device. BACKGROUND: The TC approach for TAVR holds the potential to become the optimal alternative to the transfemoral gold standard. Limited data exist regarding safety and efficacy of TC-TAVR using the Edwards Sapien 3 device. METHODS: The French Transcarotid TAVR prospective multicenter registry included patients between 2014 and 2018. Consecutive patients treated in 1 of the 13 participating centers ineligible for transfemoral TAVR were screened for TC-TAVR. Clinical and echocardiographic data were prospectively collected. Perioperative and 30-day outcomes were reported according to the updated Valve Academic Research Consortium (VARC-2). RESULTS: A total of 314 patients were included with a median (interquartile range) age of 83 (78 to 88) years, 63% were males, Society of Thoracic Surgeons mortality risk score 5.8% (4% to 8.3%). Most patients presented with peripheral artery disease (64%). TC-TAVR was performed under general anesthesia in 91% of cases, mostly using the left carotid artery (73.6%) with a procedural success of 97%. Three annulus ruptures were reported, all resulting in patient death. At 30 days, rates of major bleeding, new permanent pacemaker, and stroke or transient ischemic attack were 4.1%, 16%, and 1.6%, respectively. The 30-day mortality was 3.2%. CONCLUSIONS: TC-TAVR using the Edwards Sapien 3 device was safe and effective in this prospective multicenter registry. The TC approach might be considered, in selected patients, as the first-line alternative approach for TAVR whenever the transfemoral access is prohibited. Sapien 3 device was safe and effective in our multicenter cohort.
Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Artérias Carótidas , Cateterismo Periférico , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Feminino , França , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Estudos Prospectivos , Desenho de Prótese , Punções , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do TratamentoRESUMO
OBJECTIVE: To determine whether coronary computed tomography angiography (CTA) should be performed in patients with any clinical probability of coronary artery disease (CAD), and whether the diagnostic performance differs between subgroups of patients. DESIGN: Prospectively designed meta-analysis of individual patient data from prospective diagnostic accuracy studies. DATA SOURCES: Medline, Embase, and Web of Science for published studies. Unpublished studies were identified via direct contact with participating investigators. ELIGIBILITY CRITERIA FOR SELECTING STUDIES: Prospective diagnostic accuracy studies that compared coronary CTA with coronary angiography as the reference standard, using at least a 50% diameter reduction as a cutoff value for obstructive CAD. All patients needed to have a clinical indication for coronary angiography due to suspected CAD, and both tests had to be performed in all patients. Results had to be provided using 2×2 or 3×2 cross tabulations for the comparison of CTA with coronary angiography. Primary outcomes were the positive and negative predictive values of CTA as a function of clinical pretest probability of obstructive CAD, analysed by a generalised linear mixed model; calculations were performed including and excluding non-diagnostic CTA results. The no-treat/treat threshold model was used to determine the range of appropriate pretest probabilities for CTA. The threshold model was based on obtained post-test probabilities of less than 15% in case of negative CTA and above 50% in case of positive CTA. Sex, angina pectoris type, age, and number of computed tomography detector rows were used as clinical variables to analyse the diagnostic performance in relevant subgroups. RESULTS: Individual patient data from 5332 patients from 65 prospective diagnostic accuracy studies were retrieved. For a pretest probability range of 7-67%, the treat threshold of more than 50% and the no-treat threshold of less than 15% post-test probability were obtained using CTA. At a pretest probability of 7%, the positive predictive value of CTA was 50.9% (95% confidence interval 43.3% to 57.7%) and the negative predictive value of CTA was 97.8% (96.4% to 98.7%); corresponding values at a pretest probability of 67% were 82.7% (78.3% to 86.2%) and 85.0% (80.2% to 88.9%), respectively. The overall sensitivity of CTA was 95.2% (92.6% to 96.9%) and the specificity was 79.2% (74.9% to 82.9%). CTA using more than 64 detector rows was associated with a higher empirical sensitivity than CTA using up to 64 rows (93.4% v 86.5%, P=0.002) and specificity (84.4% v 72.6%, P<0.001). The area under the receiver-operating-characteristic curve for CTA was 0.897 (0.889 to 0.906), and the diagnostic performance of CTA was slightly lower in women than in with men (area under the curve 0.874 (0.858 to 0.890) v 0.907 (0.897 to 0.916), P<0.001). The diagnostic performance of CTA was slightly lower in patients older than 75 (0.864 (0.834 to 0.894), P=0.018 v all other age groups) and was not significantly influenced by angina pectoris type (typical angina 0.895 (0.873 to 0.917), atypical angina 0.898 (0.884 to 0.913), non-anginal chest pain 0.884 (0.870 to 0.899), other chest discomfort 0.915 (0.897 to 0.934)). CONCLUSIONS: In a no-treat/treat threshold model, the diagnosis of obstructive CAD using coronary CTA in patients with stable chest pain was most accurate when the clinical pretest probability was between 7% and 67%. Performance of CTA was not influenced by the angina pectoris type and was slightly higher in men and lower in older patients. SYSTEMATIC REVIEW REGISTRATION: PROSPERO CRD42012002780.
Assuntos
Angina Pectoris/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Angina Pectoris/etiologia , Doença da Artéria Coronariana/complicações , Estudos de Viabilidade , Humanos , Valor Preditivo dos Testes , ProbabilidadeRESUMO
BACKGROUND AND AIM OF THE STUDY: The study aim was to compare, prospectively, the planimetry of aortic stenosis on 64-slice computed tomography (CT), with the area calculated by Doppler transthoracic echocardiography (TTE) in symptomatic patients evaluated before potential aortic valve replacement. METHODS: Fifty-two consecutive patients (27 males, 25 females; mean age 74 +/- 10 years) admitted to the authors' institution during 2005 were evaluated with 64-slice CT and Doppler TTE. The time interval between the two evaluations was 2 +/- 1 weeks. Planimetry of the anatomic orifice area (AOA) drawn on 64-slice CT was compared to the effective area determined by Doppler TTE by Bland and Altman analysis, and the anatomic area threshold value corresponding to a significant effective aortic stenosis (50.75 cm2) was determined by receiver operating characteristic (ROC) analysis. RESULTS: The aortic orifice area measured by 64-slice CT correlated well with the effective area (r = 0.76; p <0.0001), but was significantly greater, with a systematic overestimation (0.132 cm(2)) and a variability of 0.239 cm(2). There was good agreement between planimetry determined by two independent radiologists (difference = 0.002, variability = 0.115 cm(2)). ROC analysis showed that a threshold value of 0.95 cm(2) as measured by 64-slice CT planimetry identifies significant aortic stenosis with sensitivity, specificity, accuracy, positive and negative predictive values of 82%, 77%, 81%, 91% and 59%, respectively. CONCLUSION: 64-slice CT is a reproducible and reliable non-invasive method to evaluate aortic valve stenosis compared to the reference method of Doppler TTE. Indeed, the CT approach could replace the latter evaluation when measurements used in the continuity equation are inadequate.