Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
BMC Pulm Med ; 23(1): 477, 2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-38017501

RESUMO

BACKGROUND: Continuous positive airway pressure (CPAP) therapy has profound effects in obesity hypoventilation syndrome (OHS). Current therapy initiation focuses on upper airway patency rather than the assessment of altered respiratory mechanics due to increased extrapulmonary mechanical load. METHODS: We aimed to examine the viability of intra-breath oscillometry in optimizing CPAP therapy for OHS. We performed intra-breath oscillometry at 10 Hz in the sitting and supine positions, followed by measurements at increasing CPAP levels (none-5-10-15-20 cmH2O) in awake OHS patients. We plotted intra-breath resistance and reactance (Xrs) values against flow (V') and volume (V) to identify tidal expiratory flow limitation (tEFL). RESULTS: Thirty-five patients (65.7% male) completed the study. We found a characteristic looping of the Xrs vs V' plot in all patients in the supine position revealing tEFL: Xrs fell with decreasing flow at end-expiration. Intra-breath variables representing expiratory decrease of Xrs became more negative in the supine position [end-expiratory Xrs (mean ± SD): -1.9 ± 1.8 cmH2O·s·L- 1 sitting vs. -4.2 ± 2.2 cmH2O·s·L- 1 supine; difference between end-expiratory and end-inspiratory Xrs: -1.3 ± 1.7 cmH2O·s·L- 1 sitting vs. -3.6 ± 2.0 cmH2O·s·L- 1 supine, p < 0.001]. Increasing CPAP altered expiratory Xrs values and loop areas, suggesting diminished tEFL (p < 0.001). 'Optimal CPAP' value (able to cease tEFL) was 14.8 ± 4.1 cmH2O in our cohort, close to the long-term support average of 13.01(± 2.97) cmH2O but not correlated. We found no correlation between forced spirometry values, patient characteristics, apnea-hypopnea index and intra-breath oscillometry variables. CONCLUSIONS: tEFL, worsened by the supine position, can be diminished by stepwise CPAP application in most patients. Intra-breath oscillometry is a viable method to detect tEFL during CPAP initiation in OHS patients and tEFL is a possible target for optimizing therapy in OHS patients.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Síndrome de Hipoventilação por Obesidade , Humanos , Masculino , Feminino , Síndrome de Hipoventilação por Obesidade/terapia , Oscilometria/métodos , Expiração , Mecânica Respiratória
2.
Sensors (Basel) ; 23(2)2023 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-36679755

RESUMO

(1) Background and Goal: Several studies have investigated the association of sleep, diurnal patterns, and circadian rhythms with the presence and with the risk states of mental illnesses such as schizophrenia and bipolar disorder. The goal of our study was to examine actigraphic measures to identify features that can be extracted from them so that a machine learning model can detect premorbid latent liabilities for schizotypy and bipolarity. (2) Methods: Our team developed a small wrist-worn measurement device that collects and identifies actigraphic data based on an accelerometer. The sensors were used by carefully selected healthy participants who were divided into three groups: Control Group (C), Cyclothymia Factor Group (CFG), and Positive Schizotypy Factor Group (PSF). From the data they collected, our team performed data cleaning operations and then used the extracted metrics to generate the feature combinations deemed most effective, along with three machine learning algorithms for categorization. (3) Results: By conducting the training, we were able to identify a set of mildly correlated traits and their order of importance based on the Shapley value that had the greatest impact on the detection of bipolarity and schizotypy according to the logistic regression, Light Gradient Boost, and Random Forest algorithms. (4) Conclusions: These results were successfully compared to the results of other researchers; we had a similar differentiation in features used by others, and successfully developed new ones that might be a good complement for further research. In the future, identifying these traits may help us identify people at risk from mental disorders early in a cost-effective, automated way.


Assuntos
Transtorno Bipolar , Esquizofrenia , Humanos , Transtorno Bipolar/diagnóstico , Actigrafia/métodos , Esquizofrenia/diagnóstico , Sono , Ritmo Circadiano
3.
Eur Respir J ; 53(2)2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30464010

RESUMO

Lower respiratory tract illness (LRTI) is a leading cause of mortality and morbidity in children. Sensitive and noninvasive infant lung function techniques are needed to measure risk for and impact of LRTI on lung health. The objective of this study was to investigate whether lung function derived from the intra-breath forced oscillation technique (FOT) was able to identify healthy infants at risk of LRTI in the first year of life.Lung function was measured with the novel intra-breath FOT, in 6-week-old infants in a South African birth cohort (Drakenstein Child Health Study). LRTI during the first year was confirmed by study staff. The association between baseline lung function and LRTI was assessed with logistic regression and odds ratios determined using optimal cut-off values.Of the 627 healthy infants with successful lung function testing, 161 (24%) had 238 LRTI episodes subsequently during the first year. Volume dependence of respiratory resistance (ΔR) and reactance (ΔX) was associated with LRTI. The predictive value was stronger if LRTI was recurrent (n=50 (31%): OR 2.5, ΔX), required hospitalisation (n=38 (16%): OR 5.4, ΔR) or was associated with wheeze (n=87 (37%): OR 3.9, ΔX).Intra-breath FOT can identify healthy infants at risk of developing LRTI, wheezing or severe illness in the first year of life.


Assuntos
Pulmão/fisiopatologia , Testes de Função Respiratória , Mecânica Respiratória , Infecções Respiratórias/fisiopatologia , Antropometria , Feminino , Humanos , Lactente , Masculino , Morbidade , Razão de Chances , Oscilometria , Valor Preditivo dos Testes , Análise de Regressão , Sons Respiratórios/fisiopatologia , Risco , África do Sul/epidemiologia
4.
Eur Respir J ; 49(2)2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28202552

RESUMO

Tracking of the within-breath changes of respiratory mechanics using the forced oscillation technique may provide outcomes that characterise the dynamic behaviour of the airways during normal breathing.We measured respiratory resistance (Rrs) and reactance (Xrs) at 8 Hz in 55 chronic obstructive pulmonary disease (COPD) patients and 20 healthy controls, and evaluated Rrs and Xrs as functions of gas flow (V') and volume (V) during normal breathing cycles. In 12 COPD patients, additional measurements were made at continuous positive airway pressure (CPAP) levels of 4, 8, 14 and 20 hPa.The Rrs and Xrsversus V' and V relationships displayed a variety of loop patterns, allowing characterisation of physiological and pathological processes. The main outcomes emerging from the within-breath analysis were the Xrsversus V loop area (AXV) quantifying expiratory flow limitation, and the tidal change in Xrs during inspiration (ΔXI) reflecting alteration in lung inhomogeneity in COPD. With increasing CPAP, AXV and ΔXI approached the normal ranges, although with a large variability between individuals, whereas mean Rrs remained unchanged.Within-breath tracking of Rrs and Xrs allows an improved assessment of expiratory flow limitation and functional inhomogeneity in COPD; thereby it may help identify the physiological phenotypes of COPD and determine the optimal level of respiratory support.


Assuntos
Resistência das Vias Respiratórias , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/terapia , Idoso , Estudos de Casos e Controles , Pressão Positiva Contínua nas Vias Aéreas , Impedância Elétrica , Expiração , Feminino , Humanos , Hungria , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Respiração , Testes de Função Respiratória/métodos
5.
Thorax ; 71(10): 907-15, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27178219

RESUMO

RATIONALE: Individual assessment of airway obstruction in preschool-age children requires sensitive and specific lung function methods with low demand of cooperation. Although the forced oscillation technique (FOT) is feasible in young children, conventional measurements of respiratory impedance (Zrs) have limited diagnostic power in individuals. OBJECTIVE: To find descriptors of within-breath Zrs that are sensitive indicators of airway obstruction during tidal breathing in children. METHODS: Zrs was measured with (i) a standard multifrequency FOT (4-26 Hz) to assess the mean values of resistance and reactance for whole breaths and (ii) a 10 Hz signal to track the within-breath changes. Various Zrs measures obtained in healthy children (n=75) and those with acute wheeze (n=31) were investigated with receiver operator characteristic (ROC) analysis. The cut-off values obtained for airway obstruction were then tested in children with recurrent wheeze (n=20) before and after administration of salbutamol. RESULTS: The largest area under the ROC curve (0.95) was observed for the tidal changes of resistance between the zero-flow values (ΔR). The ΔR cut-off value of 1.42 hPa s/L detected airway obstruction with sensitivity of 92% and specificity of 89% in children with acute wheeze and distinguished children with recurrent wheeze (16/20 above the cut-off value) from healthy children (22/23 below the cut-off value). Furthermore, ΔR significantly decreased after salbutamol in wheezy children but remained unchanged in healthy children. CONCLUSIONS: New lung function measure ΔR is able to detect airway obstruction with high sensitivity and specificity and is suitable for use in lung function testing in young children.


Assuntos
Resistência das Vias Respiratórias/fisiologia , Pneumopatias Obstrutivas/diagnóstico , Volume de Ventilação Pulmonar/fisiologia , Resistência das Vias Respiratórias/efeitos dos fármacos , Albuterol/farmacologia , Antropometria/métodos , Asma/complicações , Asma/diagnóstico , Asma/fisiopatologia , Broncodilatadores/farmacologia , Criança , Pré-Escolar , Feminino , Humanos , Pneumopatias Obstrutivas/complicações , Pneumopatias Obstrutivas/fisiopatologia , Masculino , Curva ROC , Recidiva , Testes de Função Respiratória/métodos , Sons Respiratórios/etiologia , Sons Respiratórios/fisiopatologia , Sensibilidade e Especificidade
6.
Respirology ; 20(3): 467-73, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25581268

RESUMO

BACKGROUND AND OBJECTIVE: Non-invasive techniques for measuring lung mechanics in infants are needed for a better understanding of lung growth and function, and to study the effects of prenatal factors on subsequent lung growth in healthy infants. The forced oscillation technique requires minimal cooperation from the individual but has rarely been used in infants. The study aims to assess the use of the forced oscillation technique to measure the influence of antenatal exposures on respiratory mechanics in unsedated infants enrolled in a birth cohort study in Cape Town, South Africa. METHODS: Healthy term infants were studied at 6-10 weeks of age using the forced oscillation technique. Respiratory impedance was measured in the frequency range 8-48 Hz via a face mask during natural sleep. Respiratory system resistance, compliance and inertance were calculated from the impedance spectra. RESULTS: Of 177 infants tested, successful measurements were obtained in 164 (93%). Median (25-75%) values for resistance, compliance and inertance were 50.2 (39.5-60.6) cmH2 O.s.L(-1), 0.78 (0.61-0.99) mL.cmH2 O(-1) and 0.062 (0.050-0.086) cmH2 O.s(2) .L(-1), respectively. As a group, male infants had 16% higher resistance (P = 0.006) and 18% lower compliance (P = 0.02) than females. Infants whose mothers smoked during pregnancy had a 19% lower compliance than infants not exposed to tobacco smoke during pregnancy (P = 0.005). Neither maternal HIV infection nor ethnicity had a significant effect on respiratory mechanics. CONCLUSIONS: The forced oscillation technique is sensitive enough to demonstrate the effects of tobacco smoke exposure and sex in respiratory mechanics in healthy infants. This technique will facilitate assessing perinatal influences of lung function in infancy.


Assuntos
Exposição Materna/efeitos adversos , Testes de Função Respiratória/métodos , Fenômenos Fisiológicos Respiratórios , Fumar/efeitos adversos , Impedância Elétrica , Feminino , Humanos , Recém-Nascido , Masculino , Gravidez , Valores de Referência , Sistema Respiratório , África do Sul
7.
Sci Rep ; 14(1): 2604, 2024 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-38297022

RESUMO

The scale-free nature of daily human activity has been observed in different aspects; however, the description of its spectral characteristics is incomplete. General findings are complicated by the fact that-although actigraphy is commonly used in many research areas-the activity calculation methods are not standardized; therefore, activity signals can be different. The presence of 1/f noise in activity or acceleration signals was mostly analysed for short time windows, and the complete spectral characteristic has only been examined in the case of certain types of them. To explore the general spectral nature of human activity in greater detail, we have performed Power Spectral Density (PSD) based examination and Detrended Fluctuation Analysis (DFA) on several-day-long, triaxial actigraphic acceleration signals of 42 healthy, free-living individuals. We generated different types of activity signals from these, using different acceleration preprocessing techniques and activity metrics. We revealed that the spectra of different types of activity signals generally follow a universal characteristic including 1/f noise over frequencies above the circadian rhythmicity. Moreover, we discovered that the PSD of the raw acceleration signal has the same characteristic. Our findings prove that the spectral scale-free nature is generally inherent to the motor activity of healthy, free-living humans, and is not limited to any particular activity calculation method.


Assuntos
Atividades Cotidianas , Ritmo Circadiano , Humanos , Ruído , Actigrafia , Aceleração
8.
Pacing Clin Electrophysiol ; 36(7): 845-54, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23510088

RESUMO

BACKGROUND: Triggers from thoracic veins have been implicated not only in the initiation, but also in the perpetuation of paroxysmal atrial fibrillation (PAF). To investigate their role we studied the distribution and stability of dominant frequencies (DFs) during PAF and the response to isolation of the triggering pulmonary vein (PV). METHODS AND RESULTS: Triggering structures inducing PAF were identified during isoproterenol challenge in 26 patients (15 males, 55 ± 8.5 years). During sustained PAF, sequential recordings were made with a decapolar circular mapping catheter from each PV and the left atrial posterior wall (LAPW), together with coronary sinus (CS) and right atrium (RA) recordings. DF was determined using fast Fourier transformation. Recordings were repeated after ≥15 minutes of PAF. Radiofrequency ablation was directed first at the triggering PVs. PAF initiated from the PVs in 24 patients and from RA in two. There was a significant frequency gradient from the triggering structure to the PVs, CS, LAPW, and RA (P < 0.0001). During the second recording, DF decreased at all sites (P < 0.02), but the frequency gradient remained unchanged. Despite isolation of the triggering PV, PAF continued in 53% of patients, although DF measured in the CS was lower. AF termination occurred with contralateral PV isolation in half of the remaining patients and further AF slowing was noted in the rest. CONCLUSIONS: Triggering structures harbor the fastest activity during sustained PAF pointing to their leading role in arrhythmia perpetuation. However, nontriggering PVs also seem to contribute to PAF maintenance.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Mapeamento Potencial de Superfície Corporal/métodos , Estimulação Cardíaca Artificial/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Sistema de Condução Cardíaco/fisiopatologia , Veias Pulmonares/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Doença Crônica , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento
9.
Physiol Meas ; 43(4)2022 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-35263717

RESUMO

Objective. Recent studies in respiratory system impedance (Zrs) with single-frequency oscillometry have demonstrated the utility of novel intra-breath measures of Zrs in the detection of pathological alterations in respiratory mechanics. In the present work, we addressed the feasibility of extracting intra-breath information from Zrs data sets obtained with conventional oscillometry.Approach. Multi-frequency recordings obtained in a pulmonology practice were re-analysed to track the 11 Hz component of Zrs during normal breathing and compare the intra-breath measures to that obtained with a single 10 Hz signal in the same subjects. A nonlinear model was employed to simulate changes in Zrs in the breathing cycle. The values of resistance (R) and reactance (X) at end expiration and end inspiration and their corresponding differences (ΔRand ΔX) were compared.Main results. All intra-breath measures exhibited similar mean values at 10 and 11 Hz in each subject; however, the variabilities were higher at 11 Hz, especially for ΔRand ΔX. The poorer quality of the 11 Hz data was primarily caused by the overlapping of modulation side lobes of adjacent oscillation frequencies. This cross-talk was enhanced by double breathing frequency components due to flow nonlinearities.Significance. Retrospective intra-breath assessment of large or special data bases of conventional oscillometry can be performed to better characterise respiratory mechanics in different populations and disease groups. The results also have implications in the optimum design of multiple-frequency oscillometry (avoidance of densely spaced frequencies) and the use of filtering procedures that preserve the intra-breath modulation information.


Assuntos
Mecânica Respiratória , Sistema Respiratório , Impedância Elétrica , Humanos , Oscilometria/métodos , Estudos Retrospectivos
10.
J Interv Card Electrophysiol ; 63(2): 323-331, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33871788

RESUMO

PURPOSE: Various ventricular pacing maneuvers have been developed to differentiate orthodromic reciprocating tachycardia (ORT) from atrioventricular nodal reentry tachycardia (AVNRT). We aimed to evaluate the diagnostic value of ventricular pacing maneuvers in patients undergoing catheter ablation for AVNRT/ORT. METHODS: Sixty patients with supraventricular tachycardia (SVT) undergoing invasive EP study were included (ORT: 31, typical AVNRT: 18, atypical AVNRT: 11). Ventricular overdrive pacing (VOP) and resetting by premature ventricular stimulation (PVS) during SVT were analyzed by 3 independent observers blinded to the ultimate diagnosis. We determined intraclass correlation coefficient (ICC) for interobserver agreement and the diagnostic accuracy of consensual results. RESULTS: Although specificity of all parameters was high (96-100%) for ORT, semi-quantitative parameters of VOP (requiring the recognition of specific ECG patterns) had lower interobserver reliability (ICC: 0.32-0.66) and sensitivity (16.1-77.4%). In contrast, most quantitative measurements of VOP and PVS showed good reproducibility (ICC: 0.93-0.95) and sensitivity (74.2-89.3%), but post-pacing interval after VOP needed correction with AV nodal conduction slowing. False negative results for diagnosing ORT were more common with left free wall vs. right free wall or septal, and slowly vs. fast-conducting septal APs. False positivity was only seen with a bystander, concealed nodo-fascicular/nodo-ventricular (NF/NV) AP in a case of AVNRT. CONCLUSIONS: No single maneuver is 100% sensitive for ORT. Semi-quantitative features have limited reproducibility and all parameters can be misleading in the case of rate-dependent delay during VOP/PVS, ORT circuits remote from the pacing site, or a bystander, concealed NF/NV AP.


Assuntos
Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Reciprocante , Estimulação Cardíaca Artificial/métodos , Diagnóstico Diferencial , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/cirurgia , Humanos , Reprodutibilidade dos Testes , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Reciprocante/diagnóstico , Taquicardia Reciprocante/cirurgia
11.
Front Pediatr ; 10: 867883, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35444964

RESUMO

Background: Oscillometry has been employed widely as a non-invasive and standardized measurement of respiratory function in children and adults; however, limited information is available on infants. Aims: To establish the within-session variability of respiratory impedance (Zrs), to characterize the degree and profile of intra-breath changes in Zrs and to assess their impact on conventional oscillometry in newborns. Methods: 109 healthy newborns were enrolled in the study conducted in the first 5 postpartum days during natural sleep. A custom-made wave-tube oscillometry setup was used, with an 8-48 Hz pseudorandom and a 16 Hz sinusoidal signal used for spectral and intra-breath oscillometry, respectively. A resistance-compliance-inertance (R-C-L) model was fitted to average Zrs spectra obtained from successive 30-s recordings. Intra-breath measures, such as resistance (Rrs) and reactance (Xrs) at the end-expiratory, end-inspiratory and maximum-flow points were estimated from three 90-s recordings. All natural and artifact-free breaths were included in the analysis. Results: Within-session changes in the mean R, C and L values, respectively, were large (mean coefficients of variation: 10.3, 20.3, and 26.6%); the fluctuations of the intra-breath measures were of similar degree (20-24%). Intra-breath analysis also revealed large swings in Rrs and Xrs within the breathing cycle: the peak-to-peak changes amounted to 93% (range: 32-218%) and 41% (9-212%), respectively, of the zero-flow Zrs magnitude. Discussion: Intra-breath tracking of Zrs provides new insight into the determinants of the dynamics of respiratory system, and highlights the biasing effects of mechanical non-linearities on the average Zrs data obtained from the conventional spectral oscillometry.

12.
PLoS One ; 16(12): e0261718, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34932595

RESUMO

Actigraphic measurements are an important part of research in different disciplines, yet the procedure of determining activity values is unexpectedly not standardized in the literature. Although the measured raw acceleration signal can be diversely processed, and then the activity values can be calculated by different activity calculation methods, the documentations of them are generally incomplete or vary by manufacturer. These numerous activity metrics may require different types of preprocessing of the acceleration signal. For example, digital filtering of the acceleration signals can have various parameters; moreover, both the filter and the activity metrics can also be applied per axis or on the magnitudes of the acceleration vector. Level crossing-based activity metrics also depend on threshold level values, yet the determination of their exact values is unclear as well. Due to the serious inconsistency of determining activity values, we created a detailed and comprehensive comparison of the different available activity calculation procedures because, up to the present, it was lacking in the literature. We assessed the different methods by analysing the triaxial acceleration signals measured during a 10-day movement of 42 subjects. We calculated 148 different activity signals for each subject's movement using the combinations of various types of preprocessing and 7 different activity metrics applied on both axial and magnitude data. We determined the strength of the linear relationship between the metrics by correlation analysis, while we also examined the effects of the preprocessing steps. Moreover, we established that the standard deviation of the data series can be used as an appropriate, adaptive and generalized threshold level for the level intersection-based metrics. On the basis of these results, our work also serves as a general guide on how to proceed if one wants to determine activity from the raw acceleration data. All of the analysed raw acceleration signals are also publicly available.


Assuntos
Actigrafia/estatística & dados numéricos , Exercício Físico/estatística & dados numéricos , Actigrafia/instrumentação , Adolescente , Adulto , Interpretação Estatística de Dados , Feminino , Humanos , Masculino , Modelos Estatísticos , Adulto Jovem
13.
Photosynth Res ; 105(1): 73-82, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20454858

RESUMO

A pump and probe fluorometer with a laser diode as single light source has been constructed for measurement of fast induction and relaxation of the fluorescence yield in intact cells, chromatophores and isolated reaction centers of photosynthetic bacteria. The time resolution of the fluorometer is limited by the repetition time of the probing flashes to 20 micros. The apparatus offers high sensitivity, excellent performance and can become a versatile device for a range of demanding applications. Some of them are demonstrated here including fast and easy investigation of the (1) organization and redox state of the photosynthetic apparatus of the intact cells of different bacterial strains and mutants and (2) electron transfer reactions on donor and acceptor sides of isolated reaction centers. The compact design of the mechanics, optics, electronics, and data processing makes the device easy to use as outdoor instrument or to integrate into larger measuring systems.


Assuntos
Bacterioclorofilas/metabolismo , Fluorometria/instrumentação , Fluorometria/métodos , Bactérias/metabolismo , Fotossíntese/fisiologia
14.
J Appl Physiol (1985) ; 129(3): 591-598, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32702268

RESUMO

Oscillometric measurements of respiratory system resistance (Rrs) in infants are usually made via the nasal pathways, which not only significantly contribute to overall Rrs but also introduce marked flow (V')-dependent changes. We employed intrabreath oscillometry in casts of the upper airways constructed from head CT images of 46 infants. We examined oscillometric nasal resistance (Rn) in upper airway casts with no respiratory flow (R0) and the effect of varying V' on Rn by simulating tidal breathing. A characteristic nonlinear relationship was found between Rn and V', exhibiting segmental linearity and a prominent breakpoint (V'bp) after log-log transformation. V'bp was linearly related to the preceding value of end-expiratory volume acceleration (V″eE; on average r2 = 0.96, P < 0.001). Rn depended on V', and R at end-expiration (ReE) showed a strong dependence on V″eE in every cast (r2 = 0.994, P < 001) with considerable interindividual variability. The intercept of the linear regression of ReE versus V″eE was found to be a close estimate of R0. These findings were utilized in reanalyzed Rrs data acquired in vivo in a small group of infants (n = 15). Using a graphical method to estimate R0 from ReE, we found a relative contribution of V'-dependent nonlinearity to total resistance of up to 33%. In conclusion, we propose a method for correcting the acceleration-dependent nonlinearity error in ReE. This correction can be adapted to estimate R0 from a single intrabreath oscillometric measurement, which would reduce the masking effects of the upper airways on the changes in the intrathoracic resistance.NEW & NOTEWORTHY Oscillometric measurements of respiratory system resistance (Rrs) in infants are usually made via the nasal pathways, which not only significantly contribute to overall Rrs but also introduce marked flow acceleration-dependent distortions. Here, we propose a method for correcting flow acceleration-dependent nonlinearity error based on in vitro measurements in 3D-printed upper airway casts of infants as well as in vivo measurements. This correction can be adapted to estimate Rrs from a single intrabreath oscillometric measurement.


Assuntos
Resistência das Vias Respiratórias , Respiração , Humanos , Lactente , Modelos Lineares , Oscilometria , Respiração Artificial
15.
J Healthc Eng ; 2018: 4038034, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29666670

RESUMO

Background: Heart rate variability (HRV) provides information about the activity of the autonomic nervous system. Because of the small amount of data collected, the importance of HRV has not yet been proven in clinical practice. To collect population-level data, smartphone applications leveraging photoplethysmography (PPG) and some medical knowledge could provide the means for it. Objective: To assess the capabilities of our smartphone application, we compared PPG (pulse rate variability (PRV)) with ECG (HRV). To have a baseline, we also compared the differences among ECG channels. Method: We took fifty parallel measurements using iPhone 6 at a 240 Hz sampling frequency and Cardiax PC-ECG devices. The correspondence between the PRV and HRV indices was investigated using correlation, linear regression, and Bland-Altman analysis. Results: High PPG accuracy: the deviation of PPG-ECG is comparable to that of ECG channels. Mean deviation between PPG-ECG and two ECG channels: RR: 0.01 ms-0.06 ms, SDNN: 0.78 ms-0.46 ms, RMSSD: 1.79 ms-1.21 ms, and pNN50: 2.43%-1.63%. Conclusions: Our iPhone application yielded good results on PPG-based PRV indices compared to ECG-based HRV indices and to differences among ECG channels. We plan to extend our results on the PPG-ECG correspondence with a deeper analysis of the different ECG channels.


Assuntos
Frequência Cardíaca/fisiologia , Pulso Arterial/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Smartphone , Adulto , Eletrocardiografia/instrumentação , Eletrocardiografia/métodos , Feminino , Humanos , Masculino , Fotopletismografia/instrumentação , Fotopletismografia/métodos , Pulso Arterial/métodos
16.
Clin Physiol Funct Imaging ; 27(4): 205-10, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17564668

RESUMO

The aim of this study was to assess the influence of breathing pattern on the reproducibility of the most commonly used heart rate and blood pressure variability parameters and baroreflex indices. 5-5 min ECG and blood pressure recordings were made and repeated for 10 healthy volunteers in supine rest on 10 consecutive days during spontaneous and 6 min(-1) patterned breathing. We investigated the following parameters: mean RR interval (RRI); the standard deviation of RR intervals (SDRR); the root mean square of successive differences in RRI (RMSSD); the percentage of RRIs which differed by 50% from the proceeding RRI (PNN50); mean systolic arterial pressure (SAP); the standard deviation of SAP (SAP SD); mean mean arterial pressure (MAP); mean diastolic blood pressure (DAP) and baroreflex indices from spontaneous sequence method (upBRS and downBRS) and from cross spectral analysis (LF alpha, HF alpha). To assess reproducibility for each parameter within- and between-subject variability values were calculated and the ratio of within- and between-subject variability was assessed. In addition, we calculated intraclass correlation coefficient (ICC). Compared to spontaneous respiration during 6 min(-1) patterned breathing the heart rate and blood pressure variability increased; upBRS, LF alpha and HF alpha increased, downBRS did not change. However, ICC showed good reproducibility for most parameters, which did not improve further with controlled breathing. In conclusion, respiration had a strong influence on the most widely used cardiovascular autonomic parameters. The controlling of breathing did not result in consistent improvement in their reproducibility.


Assuntos
Sistema Nervoso Autônomo/fisiologia , Fenômenos Fisiológicos Cardiovasculares , Mecânica Respiratória/fisiologia , Adulto , Análise de Variância , Barorreflexo/fisiologia , Pressão Sanguínea/fisiologia , Eletrocardiografia , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Decúbito Dorsal/fisiologia
17.
Orv Hetil ; 147(52): 2515-21, 2006 Dec 31.
Artigo em Húngaro | MEDLINE | ID: mdl-17294576

RESUMO

UNLABELLED: Intravascular stent implantation is an attractive therapy for carotid artery stenosis. Severe complications of the interventional procedure however include stroke and death. AIMS: It has been suggested, that episodes of temporary bradycardia and hypotension upon balloon inflation could be related to adverse outcome. METHODS: In order to assess the significance of episodic haemodynamic instability 24 consecutive patients were continuously monitored during intravascular intervention. Heart rate and blood pressure variability parameters of the patients, and indices of spontaneous baroreflex sensitivity were determined prior to the procedures. The authors have assessed the potential correlation between the autonomic markers recorded on baseline and the subsequent occurrence of reflex mediated haemodynamic instability. RESULTS: The authors observations confirmed that bradycardia and hypotension occurs frequently at the time of stent after-dilation. Pauses in excess of 3 seconds occurred in 29% of patients. Atropine was administered at 7 instances. The magnitude of systolic blood pressure drop was greater among patients with pauses, however substantial pressure drop was seen among those without pauses as well. No severe complications were seen. Heart rate variability and spontaneous baroreflex sensitivity were reduced in the whole studied population, allowing no prediction of episodes with bradycardia and hypotension. CONCLUSION: The authors findings indicate that reflex mediated haemodynamic instability induced by carotid artery intervention is a benign phenomenon. Analysis of autonomic markers is of limited value in this patient population.


Assuntos
Pressão Sanguínea , Estenose das Carótidas/fisiopatologia , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas/efeitos adversos , Frequência Cardíaca , Stents , Idoso , Bradicardia/etiologia , Bradicardia/fisiopatologia , Eletrocardiografia , Endarterectomia das Carótidas/métodos , Feminino , Humanos , Hipotensão/etiologia , Hipotensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
18.
R Soc Open Sci ; 3(2): 150548, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26998325

RESUMO

Recently, we have reported on a compact microcontroller-based unit developed to accurately synchronize excimer laser pulses (Mingesz et al. 2012 Fluct. Noise Lett. 11, 1240007 (doi:10.1142/S021947751240007X)). We have shown that dithering based on random jitter noise plus pseudorandom numbers can be used in the digital control system to radically reduce the long-term drift of the laser pulse from the trigger and to improve the accuracy of the synchronization. In this update paper, we present our new experimental results obtained by the use of the delay-controller unit to tune the timing of a KrF excimer laser as an addition to our previous numerical simulation results. The hardware was interfaced to the laser using optical signal paths in order to reduce sensitivity to electromagnetic interference and the control algorithm tested by simulations was applied in the experiments. We have found that the system is able to reduce the delay uncertainty very close to the theoretical limit and performs well in real applications. The simple, compact and flexible system is universal enough to also be used in various multidisciplinary applications.

19.
J Phys Chem B ; 109(37): 17474-8, 2005 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-16853234

RESUMO

Conducting polypyrrole (PPy) powder synthesized by using FeCl3 x 6 H2O and/or Fe(NO3)3 oxidants was impregnated in silver salt solutions. The stability and decomposition of the material was followed by thermogravimetric measurements. The total silver content was determined by atom absorption spectroscopy (ICP-AAS). The heat and electric conductivities of the composites were measured and correlated with the silver content. The incorporated silver was speciated and measured by X-ray diffraction (XRD). The spectra proved that the chemical state of the silver incorporated into the composite depends on the anion used in the polymerization process. In the case of the polymerization in a nitrate ion containing solution, the impregnation leads exclusively to the formation of metallic silver. The size distribution of the AgCl and Ag nanoparticles, determined from transmission electron microscopy (TEM) pictures in the different composites, proves the formation of a rather uniform species below 10 and 7 nm, respectively. The observations can be correlated with the different interactions in the PPy-chloride/nitrate-silver systems. The redox type interaction based conclusions can be considered as a guide during the preparation of other metal-conducting polymer composites.

20.
Sci Rep ; 5: 13653, 2015 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-26333562

RESUMO

The Kirchhoff-Law-Johnson-Noise (KLJN) secure key exchange system has been introduced as a simple, very low cost and efficient classical physical alternative to quantum key distribution systems. The ideal system uses only a few electronic components-identical resistor pairs, switches and interconnecting wires-in order to guarantee perfectly protected data transmission. We show that a generalized KLJN system can provide unconditional security even if it is used with significantly less limitations. The more universal conditions ease practical realizations considerably and support more robust protection against attacks. Our theoretical results are confirmed by numerical simulations.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA