Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(3)2023 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-36772474

RESUMO

On average, arterial oxygen saturation measured by pulse oximetry (SpO2) is higher in hypoxemia than the true oxygen saturation measured invasively (SaO2), thereby increasing the risk of occult hypoxemia. In the current article, measurements of SpO2 on 17 cyanotic newborns were performed by means of a Nellcor pulse oximeter (POx), based on light with two wavelengths in the red and infrared regions (660 and 900 nm), and by means of a novel POx, based on two wavelengths in the infrared region (761 and 820 nm). The SpO2 readings from the two POxs showed higher values than the invasive SaO2 readings, and the disparity increased with decreasing SaO2. SpO2 measured using the two infrared wavelengths showed better correlation with SaO2 than SpO2 measured using the red and infrared wavelengths. After appropriate calibration, the standard deviation of the individual SpO2-SaO2 differences for the two-infrared POx was smaller (3.6%) than that for the red and infrared POx (6.5%, p < 0.05). The overestimation of SpO2 readings in hypoxemia was explained by the increase in hypoxemia of the optical pathlengths-ratio between the two wavelengths. The two-infrared POx can reduce the overestimation of SpO2 measurement in hypoxemia and the consequent risk of occult hypoxemia, owing to its smaller increase in pathlengths-ratio in hypoxemia.


Assuntos
Oximetria , Saturação de Oxigênio , Recém-Nascido , Humanos , Hipóxia , Oxigênio , Calibragem
2.
Abdom Radiol (NY) ; 46(6): 2647-2655, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33386909

RESUMO

PURPOSE: Partial obstruction of the upper urinary tract is a common urological pathology that leads to progressive atrophy and dysfunction of the kidney. Most methods for evaluating the urine drainage rate, to assess the severity of partial obstruction, involve injection of markers into the blood stream and therefore the filtration rate from the blood effects the drainage rate. This study presents a novel method for assessing the drainage rate from the upper urinary tract by analyzing sequential fluoroscopic images from a routine nephrostogram, in which contrast material is introduced directly into the renal collecting system. METHODS: Fluoroscopic images from 36 nephrostograms, following percutaneous nephrolithotomy, were retrospectively evaluated, 19 with a dilated renal pelvis. A radiological model for calculating the radiopacity of the renal pelvis, which reflects the amount of contrast material in each sequential image, was developed. Using this model, an algorithm was designed for generating a drainage curve and calculating the "drainage time" t1/2 in which half of the contrast material has drained from the renal pelvis. RESULTS: Analysis of images of a step-wedge phantom made of an increasing number of contrast material layers showed that the calculated radiopacity of each step was proportional to the amount of contrast material, independent of the background attenuation. Analysis of the nephrostograms showed that the drainage curves highly fitted an exponential function (R = 0.961), with a significantly higher t1/2 for dilated cases. CONCLUSION: The developed method may be used for a quantitative and accurate estimation of the urine drainage rate.


Assuntos
Drenagem , Pelve Renal , Meios de Contraste , Humanos , Pelve Renal/diagnóstico por imagem , Estudos Retrospectivos , Urografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA