Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Radiology ; 307(5): e222878, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37249435

RESUMO

Background Cardiac cine can benefit from deep learning-based image reconstruction to reduce scan time and/or increase spatial and temporal resolution. Purpose To develop and evaluate a deep learning model that can be combined with parallel imaging or compressed sensing (CS). Materials and Methods The deep learning model was built on the enhanced super-resolution generative adversarial inline neural network, trained with use of retrospectively identified cine images and evaluated in participants prospectively enrolled from September 2021 to September 2022. The model was applied to breath-hold electrocardiography (ECG)-gated segmented and free-breathing real-time cine images collected with reduced spatial resolution with use of generalized autocalibrating partially parallel acquisitions (GRAPPA) or CS. The deep learning model subsequently restored spatial resolution. For comparison, GRAPPA-accelerated cine images were collected. Diagnostic quality and artifacts were evaluated by two readers with use of Likert scales and compared with use of Wilcoxon signed-rank tests. Agreement for left ventricle (LV) function, volume, and strain was assessed with Bland-Altman analysis. Results The deep learning model was trained on 1616 patients (mean age ± SD, 56 years ± 16; 920 men) and evaluated in 181 individuals, 126 patients (mean age, 57 years ± 16; 77 men) and 55 healthy subjects (mean age, 27 years ± 10; 15 men). In breath-hold ECG-gated segmented cine and free-breathing real-time cine, the deep learning model and GRAPPA showed similar diagnostic quality scores (2.9 vs 2.9, P = .41, deep learning vs GRAPPA) and artifact score (4.4 vs 4.3, P = .55, deep learning vs GRAPPA). Deep learning acquired more sections per breath-hold than GRAPPA (3.1 vs one section, P < .001). In free-breathing real-time cine, the deep learning showed a similar diagnostic quality score (2.9 vs 2.9, P = .21, deep learning vs GRAPPA) and lower artifact score (3.9 vs 4.3, P < .001, deep learning vs GRAPPA). For both sequences, the deep learning model showed excellent agreement for LV parameters, with near-zero mean differences and narrow limits of agreement compared with GRAPPA. Conclusion Deep learning-accelerated cardiac cine showed similarly accurate quantification of cardiac function, volume, and strain to a standardized parallel imaging method. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Vannier and Wang in this issue.


Assuntos
Imagem Cinética por Ressonância Magnética , Imageamento por Ressonância Magnética , Masculino , Humanos , Pessoa de Meia-Idade , Adulto , Estudos Retrospectivos , Imagem Cinética por Ressonância Magnética/métodos , Função Ventricular Esquerda , Suspensão da Respiração , Redes Neurais de Computação , Reprodutibilidade dos Testes
2.
Magn Reson Med ; 88(6): 2573-2582, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35916305

RESUMO

PURPOSE: To improve the accuracy and robustness of T1 estimation by MyoMapNet, a deep learning-based approach using 4 inversion-recovery T1 -weighted images for cardiac T1 mapping. METHODS: MyoMapNet is a fully connected neural network for T1 estimation of an accelerated cardiac T1 mapping sequence, which collects 4 T1 -weighted images by a single Look-Locker inversion-recovery experiment (LL4). MyoMapNet was originally trained using in vivo data from the modified Look-Locker inversion recovery sequence, which resulted in significant bias and sensitivity to various confounders. This study sought to train MyoMapNet using signals generated from numerical simulations and phantom MR data under multiple simulated confounders. The trained model was then evaluated by phantom data scanned using new phantom vials that differed from those used for training. The performance of the new model was compared with modified Look-Locker inversion recovery sequence and saturation-recovery single-shot acquisition for measuring native and postcontrast T1 in 25 subjects. RESULTS: In the phantom study, T1 values measured by LL4 with MyoMapNet were highly correlated with reference values from the spin-echo sequence. Furthermore, the estimated T1 had excellent robustness to changes in flip angle and off-resonance. Native and postcontrast myocardium T1 at 3 Tesla measured by saturation-recovery single-shot acquisition, modified Look-Locker inversion recovery sequence, and MyoMapNet were 1483 ± 46.6 ms and 791 ± 45.8 ms, 1169 ± 49.0 ms and 612 ± 36.0 ms, and 1443 ± 57.5 ms and 700 ± 57.5 ms, respectively. The corresponding extracellular volumes were 22.90% ± 3.20%, 28.88% ± 3.48%, and 30.65% ± 3.60%, respectively. CONCLUSION: Training MyoMapNet with numerical simulations and phantom data will improve the estimation of myocardial T1 values and increase its robustness to confounders while also reducing the overall T1 mapping estimation time to only 4 heartbeats.


Assuntos
Imageamento por Ressonância Magnética , Miocárdio , Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes
3.
Magn Reson Med ; 88(4): 1720-1733, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35691942

RESUMO

PURPOSE: To develop and evaluate a free breathing non-electrocardiograph (ECG) myocardial T1 * mapping sequence using radial imaging to quantify the changes in myocardial T1 * between rest and exercise (T1 *reactivity ) in exercise cardiac MRI (Ex-CMR). METHODS: A free-running T1 * sequence was developed using a saturation pulse followed by three Look-Locker inversion-recovery experiments. Each Look-Locker continuously acquired data as radial trajectory using a low flip-angle spoiled gradient-echo readout. Self-navigation was performed with a temporal resolution of ∼100 ms for retrospectively extracting respiratory motion. The mid-diastole phase for every cardiac cycle was retrospectively detected on the recorded electrocardiogram signal using an empirical model. Multiple measurements were performed to obtain mean value to reduce effects from the free-breathing acquisition. Finally, data acquired at both mid-diastole and end-expiration are picked and reconstructed by a low-rank plus sparsity constraint algorithm. The performance of this sequence was evaluated by simulations, phantoms, and in vivo studies at rest and after physiological exercise. RESULTS: Numerical simulation demonstrated that changes in T1 * are related to the changes in T1 ; however, other factors such as breathing motion could influence T1 * measurements. Phantom T1 * values measured using free-running T1 * mapping sequence had good correlation with spin-echo T1 values and was insensitive to heart rate. In the Ex-CMR study, the measured T1 * reactivity was 10% immediately after exercise and declined over time. CONCLUSION: The free-running T1 * mapping sequence allows free-breathing non-ECG quantification of changes in myocardial T1 * with physiological exercise. Although, absolute myocardial T1 * value is sensitive to various confounders such as B1 and B0 inhomogeneity, quantification of its change may be useful in revealing myocardial tissue properties with exercise.


Assuntos
Imageamento por Ressonância Magnética , Miocárdio , Eletrocardiografia , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Estudos Retrospectivos
4.
NMR Biomed ; 35(11): e4794, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35767308

RESUMO

The objective of the current study was to investigate the performance of various deep learning (DL) architectures for MyoMapNet, a DL model for T1 estimation using accelerated cardiac T1 mapping from four T1 -weighted images collected after a single inversion pulse (Look-Locker 4 [LL4]). We implemented and tested three DL architectures for MyoMapNet: (a) a fully connected neural network (FC), (b) convolutional neural networks (VGG19, ResNet50), and (c) encoder-decoder networks with skip connections (ResUNet, U-Net). Modified Look-Locker inversion recovery (MOLLI) images from 749 patients at 3 T were used for training, validation, and testing. The first four T1 -weighted images from MOLLI5(3)3 and/or MOLLI4(1)3(1)2 protocols were extracted to create accelerated cardiac T1 mapping data. We also prospectively collected data from 28 subjects using MOLLI and LL4 to further evaluate model performance. Despite rigorous training, conventional VGG19 and ResNet50 models failed to produce anatomically correct T1 maps, and T1 values had significant errors. While ResUNet yielded good quality maps, it significantly underestimated T1 . Both FC and U-Net, however, yielded excellent image quality with good T1 accuracy for both native (FC/U-Net/MOLLI = 1217 ± 64/1208 ± 61/1199 ± 61 ms, all p < 0.05) and postcontrast myocardial T1 (FC/U-Net/MOLLI = 578 ± 57/567 ± 54/574 ± 55 ms, all p < 0.05). In terms of precision, the U-Net model yielded better T1 precision compared with the FC architecture (standard deviation of 61 vs. 67 ms for the myocardium for native [p < 0.05], and 31 vs. 38 ms [p < 0.05], for postcontrast). Similar findings were observed in prospectively collected LL4 data. It was concluded that U-Net and FC DL models in MyoMapNet enable fast myocardial T1 mapping using only four T1 -weighted images collected from a single LL sequence with comparable accuracy. U-Net also provides a slight improvement in precision.


Assuntos
Aprendizado Profundo , Interpretação de Imagem Assistida por Computador , Coração/diagnóstico por imagem , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Miocárdio , Reprodutibilidade dos Testes
5.
J Cardiovasc Magn Reson ; 24(1): 6, 2022 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-34986850

RESUMO

PURPOSE: To develop and evaluate MyoMapNet, a rapid myocardial T1 mapping approach that uses fully connected neural networks (FCNN) to estimate T1 values from four T1-weighted images collected after a single inversion pulse in four heartbeats (Look-Locker, LL4). METHOD: We implemented an FCNN for MyoMapNet to estimate T1 values from a reduced number of T1-weighted images and corresponding inversion-recovery times. We studied MyoMapNet performance when trained using native, post-contrast T1, or a combination of both. We also explored the effects of number of T1-weighted images (four and five) for native T1. After rigorous training using in-vivo modified Look-Locker inversion recovery (MOLLI) T1 mapping data of 607 patients, MyoMapNet performance was evaluated using MOLLI T1 data from 61 patients by discarding the additional T1-weighted images. Subsequently, we implemented a prototype MyoMapNet and LL4 on a 3 T scanner. LL4 was used to collect T1 mapping data in 27 subjects with inline T1 map reconstruction by MyoMapNet. The resulting T1 values were compared to MOLLI. RESULTS: MyoMapNet trained using a combination of native and post-contrast T1-weighted images had excellent native and post-contrast T1 accuracy compared to MOLLI. The FCNN model using four T1-weighted images yields similar performance compared to five T1-weighted images, suggesting that four T1 weighted images may be sufficient. The inline implementation of LL4 and MyoMapNet enables successful acquisition and reconstruction of T1 maps on the scanner. Native and post-contrast myocardium T1 by MOLLI and MyoMapNet was 1170 ± 55 ms vs. 1183 ± 57 ms (P = 0.03), and 645 ± 26 ms vs. 630 ± 30 ms (P = 0.60), and native and post-contrast blood T1 was 1820 ± 29 ms vs. 1854 ± 34 ms (P = 0.14), and 508 ± 9 ms vs. 514 ± 15 ms (P = 0.02), respectively. CONCLUSION: A FCNN, trained using MOLLI data, can estimate T1 values from only four T1-weighted images. MyoMapNet enables myocardial T1 mapping in four heartbeats with similar accuracy as MOLLI with inline map reconstruction.


Assuntos
Aprendizado Profundo , Coração , Frequência Cardíaca , Humanos , Imageamento por Ressonância Magnética , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
6.
J Cardiovasc Magn Reson ; 24(1): 47, 2022 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-35948936

RESUMO

BACKGROUND: Exercise cardiovascular magnetic resonance (Ex-CMR) is a promising stress imaging test for coronary artery disease (CAD). However, Ex-CMR requires accelerated imaging techniques that result in significant aliasing artifacts. Our goal was to develop and evaluate a free-breathing and electrocardiogram (ECG)-free real-time cine with deep learning (DL)-based radial acceleration for Ex-CMR. METHODS: A 3D (2D + time) convolutional neural network was implemented to suppress artifacts from aliased radial cine images. The network was trained using synthetic real-time radial cine images simulated using breath-hold, ECG-gated segmented Cartesian k-space data acquired at 3 T from 503 patients at rest. A prototype real-time radial sequence with acceleration rate = 12 was used to collect images with inline DL reconstruction. Performance was evaluated in 8 healthy subjects in whom only rest images were collected. Subsequently, 14 subjects (6 healthy and 8 patients with suspected CAD) were prospectively recruited for an Ex-CMR to evaluate image quality. At rest (n = 22), standard breath-hold ECG-gated Cartesian segmented cine and free-breathing ECG-free real-time radial cine images were acquired. During post-exercise stress (n = 14), only real-time radial cine images were acquired. Three readers evaluated residual artifact level in all collected images on a 4-point Likert scale (1-non-diagnostic, 2-severe, 3-moderate, 4-minimal). RESULTS: The DL model substantially suppressed artifacts in real-time radial cine images acquired at rest and during post-exercise stress. In real-time images at rest, 89.4% of scores were moderate to minimal. The mean score was 3.3 ± 0.7, representing increased (P < 0.001) artifacts compared to standard cine (3.9 ± 0.3). In real-time images during post-exercise stress, 84.6% of scores were moderate to minimal, and the mean artifact level score was 3.1 ± 0.6. Comparison of left-ventricular (LV) measures derived from standard and real-time cine at rest showed differences in LV end-diastolic volume (3.0 mL [- 11.7, 17.8], P = 0.320) that were not significantly different from zero. Differences in measures of LV end-systolic volume (7.0 mL [- 1.3, 15.3], P < 0.001) and LV ejection fraction (- 5.0% [- 11.1, 1.0], P < 0.001) were significant. Total inline reconstruction time of real-time radial images was 16.6 ms per frame. CONCLUSIONS: Our proof-of-concept study demonstrated the feasibility of inline real-time cine with DL-based radial acceleration for Ex-CMR.


Assuntos
Doença da Artéria Coronariana , Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Técnicas de Imagem de Sincronização Respiratória , Doença da Artéria Coronariana/diagnóstico por imagem , Aprendizado Profundo , Teste de Esforço , Estudos de Viabilidade , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Técnicas de Imagem de Sincronização Respiratória/métodos
7.
Magn Reson Med ; 85(1): 89-102, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32662908

RESUMO

PURPOSE: To develop and validate a saturation-delay-inversion recovery preparation, slice tracking and multi-slice based sequence for measuring whole-heart native T1 . METHOD: The proposed free-breathing sequence performs T1 mapping of multiple left-ventricular slices by slice-interleaved acquisition to collect 10 electrocardiogram-triggered single-shot slice-selective images for each slice. A saturation-delay-inversion recovery pulse is used for T1 preparation. Prospective slice tracking by the diaphragm navigator and retrospective registration are used to reduce through-plane and in-plane motion, respectively. The proposed sequence was validated in both phantom and human subjects (12 healthy subjects and 15 patients who were referred for a clinical cardiac MR exam) and compared with saturation recovery single-shot acquisition (SASHA) and modified Look-Locker inversion recovery (MOLLI). RESULTS: Phantom T1 measured by the proposed sequence had excellent agreement (R2  = 0.99) with the ground-truth T1 and was insensitive to heart rate. In both healthy subjects and patients, the proposed sequence yielded nine left-ventricular T1 maps per volume in less than 2 minutes (healthy volunteers: 1.8 ± 0.4 minutes; patients: 1.9 ± 0.2 minutes). The average T1 of whole left ventricle for all healthy subjects and patients were 1560 ± 61 and 1535 ± 49 ms by SASHA, 1208 ± 42 and 1233 ± 56 ms by MOLLI5(3)3, and 1397 ± 34 and 1433 ± 56 ms by the proposed sequence, respectively. The corresponding coefficient of variation of T1 were 6.2 ± 1.4% and 5.8 ± 1.6%, 5.3 ± 1.1% and 5.1 ± 0.8%, and 4.9 ± 0.8% and 4.5 ± 0.8%, respectively. CONCLUSION: The proposed sequence enables quantification of whole heart T1 with good accuracy and precision in less than 2 minutes during free breathing.


Assuntos
Coração , Imageamento por Ressonância Magnética , Miocárdio , Coração/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos
8.
Magn Reson Med ; 86(2): 954-963, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33764599

RESUMO

PURPOSE: To reduce inflow and motion artifacts in free-breathing, free-running, steady-state spoiled gradient echo T1 -weighted (SPGR) myocardial perfusion imaging. METHOD: Unsaturated spins from inflowing blood or out-of-plane motion cause flashing artifacts in free-running SPGR myocardial perfusion. During free-running SPGR, 1 non-selective RF excitation was added after every 3 slice-selective RF excitations to suppress inflow artifacts by forcing magnetization in neighboring regions to steady-state. Bloch simulations and phantom experiments were performed to evaluate the impact of the flip angle and non-selective RF frequency on inflowing spins and tissue contrast. Free-running perfusion with (n = 11) interleaved non-selective RF or without (n = 11) were studied in 22 subjects (age = 60.2 ± 14.3 years, 11 male). Perfusion images were graded on a 5-point Likert scale for conspicuity of wall enhancement, inflow/motion artifact, and streaking artifact and compared using Wilcoxon sum-rank testing. RESULT: Numeric simulation showed that 1 non-selective RF excitation applied after every 3 slice-selective RF excitations produced superior out-of-plane signal suppression compared to 1 non-selective RF excitation applied after every 6 or 9 slice-selective RF excitations. In vitro experiments showed that a 30° flip angle produced near-optimal myocardial contrast. In vivo experiments demonstrated that the addition of interleaved non-selective RF significantly (P < .01) improved conspicuity of wall enhancement (mean score = 4.4 vs. 3.2) and reduced inflow/motion (mean score = 4.5 vs. 2.5) and streaking (mean score = 3.9 vs. 2.4) artifacts. CONCLUSION: Non-selective RF excitations interleaved between slice-selective excitations can reduce image artifacts in free-breathing, ungated perfusion images. Further studies are warranted to assess the diagnostic accuracy of the proposed solution for evaluating myocardial ischemia.


Assuntos
Artefatos , Imagem de Perfusão do Miocárdio , Idoso , Humanos , Aumento da Imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Respiração
9.
Magn Reson Med ; 85(3): 1308-1321, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33078443

RESUMO

PURPOSE: To develop a free-breathing sequence, that is, Multislice Joint T1 -T2 , for simultaneous measurement of myocardial T1 and T2 for multiple slices to achieve whole left-ventricular coverage. METHODS: Multislice Joint T1 -T2 adopts slice-interleaved acquisition to collect 10 single-shot electrocardiogram-triggered images for each slice prepared by saturation and T2 preparation to simultaneously estimate myocardial T1 and T2 and achieve whole left-ventricular coverage. Prospective slice-tracking using a respiratory navigator and retrospective image registration are used to reduce through-plane and in-plane motion, respectively. Multislice Joint T1 -T2 was validated through numerical simulations and phantom and in vivo experiments, and compared with saturation-recovery single-shot acquisition and T2 -prepared balanced Steady-State Free Precession (T2 -prep SSFP) sequences. RESULTS: Phantom T1 and T2 from Multislice Joint T1 -T2 had good accuracy and precision, and were insensitive to heart rate. Multislice Joint T1 -T2 yielded T1 and T2 maps of nine left-ventricular slices in 1.4 minutes. The mean left-ventricular T1 difference between saturation-recovery single-shot acquisition and Multislice Joint T1 -T2 across healthy subjects and patients was 191 ms (1564 ± 60 ms versus 1373 ± 50 ms; P < .05) and 111 ms (1535 ± 49 ms vs 1423 ± 49 ms; P < .05), respectively. The mean difference in left-ventricular T2 between T2 -prep SSFP and Multislice Joint T1 -T2 across healthy subjects and patients was -6.3 ms (42.4 ± 1.4 ms vs 48.7 ± 2.5; P < .05) and -5.7 ms (41.6 ± 2.5 ms vs 47.3 ± 2.7; P < .05), respectively. CONCLUSION: Multislice Joint T1 -T2 enables quantification of whole left-ventricular T1 and T2 during free breathing within a clinically feasible scan time of less than 2 minutes.


Assuntos
Ventrículos do Coração , Interpretação de Imagem Assistida por Computador , Coração , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos
10.
Magn Reson Med ; 86(2): 804-819, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33720465

RESUMO

PURPOSE: To develop and evaluate a real-time phase contrast (PC) MRI protocol via complex-difference deep learning (DL) framework. METHODS: DL used two 3D U-nets to separately filter aliasing artifact from radial real-time velocity-compensated and complex-difference images. U-nets were trained with synthetic real-time PC generated from electrocardiograph (ECG) -gated, breath-hold, segmented PC (ECG-gated segmented PC) acquired at the ascending aorta of 510 patients. In 21 patients, free-breathing, ungated real-time (acceleration rate = 28.8) and ECG-gated segmented (acceleration rate = 2) PC were prospectively acquired at the ascending aorta. Hemodynamic parameters (cardiac output [CO], stroke volume [SV], and mean velocity at peak systole [peak mean velocity]) were measured for ECG-gated segmented and DL-filtered synthetic real-time PC and compared using Bland-Altman and linear regression analyses. Additionally, hemodynamic parameters were quantified from DL-filtered, compressed-sensing (CS) -reconstructed, and gridding reconstructed prospective real-time PC and compared to ECG-gated segmented PC. RESULTS: Synthetic real-time PC with DL showed strong correlation (R > 0.98) and good agreement with ECG-gated segmented PC for quantified hemodynamic parameters (mean-difference: CO = -0.3 L/min, SV = -4.3 mL, peak mean velocity = -2.3 cm/s). On average, DL required 0.39 s/frame to filter prospective real-time PC, which was 4.6-fold faster than CS. Compared to CS, DL showed superior correlation, tighter limits of agreement (LOAs), better bias for peak mean velocity, and worse bias for CO and SV. Compared to gridding, DL showed similar correlation, tighter LOAs for CO and SV, similar bias for CO, and worse bias for SV and peak mean velocity. CONCLUSION: The complex-difference DL framework accelerated real-time PC-MRI by nearly 28-fold, enabling rapid free-running real-time assessment of flow hemodynamics.


Assuntos
Aprendizado Profundo , Velocidade do Fluxo Sanguíneo , Humanos , Imageamento por Ressonância Magnética , Estudos Prospectivos , Respiração , Volume Sistólico
11.
J Magn Reson Imaging ; 54(3): 787-794, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33650227

RESUMO

BACKGROUND: Cardiac magnetic resonance (MR) images are often collected with different imaging parameters, which may impact the calculated values of myocardial radiomic features. PURPOSE: To investigate the sensitivity of myocardial radiomic features to changes in imaging parameters in cardiac MR images. STUDY TYPE: Prospective. POPULATION: A total of 11 healthy participants/five patients. FIELD STRENGTH/ SEQUENCE: A 3 T/cine balanced steady-state free-precession, T1 -weighted spoiled gradient-echo, T2 -weighted turbo spin-echo, and quantitative T1 and T2 mapping. For each sequence, the flip angle, in-plane resolution, slice thickness, and parallel imaging technique were varied to study the sensitivity of radiomic features to alterations in imaging parameters. ASSESSMENT: Myocardial contours were manually delineated by experienced readers, and a total of 1023 radiomic features were extracted using PyRadiomics with 11 image filters and six feature families. STATISTICAL TESTS: Sensitivity was defined as the standardized mean difference (D effect size), and the robust features were defined at sensitivity < 0.2. Sensitivity analysis was performed on predefined sets of reproducible features. The analysis was performed using the entire cohort of 16 subejcts. RESULTS: 64% of radiomic features were robust (sensitivity < 0.2) to changes in any imaging parameter. In qualitative sequences, radiomic features were most sensitive to changes in in-plane spatial resolution (spatial resolution: 0.6 vs. flip angle: 0.19, parallel imaging: 0.18, slice thickness: 0.07; P < 0.01 for all); in quantitative sequences, radiomic features were least sensitive to changes in spatial resolution (spatial resolution: 0.07 vs. slice thickness: 0.16, flip angle: 0.24; P < 0.01 for all). In an individual feature level, no singular feature family/image filter was identified as robust (sensitivity < 0.2) across sequences; however, highly sensitive features were predominantly associated with high-frequency wavelet filters across all sequences (32/50 features). DATA CONCLUSION: In cardiac MR, a considerable number of radiomic features are sensitive to changes in sequence parameters. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 1.


Assuntos
Coração , Imageamento por Ressonância Magnética , Coração/diagnóstico por imagem , Humanos , Miocárdio , Estudos Prospectivos
12.
Magn Reson Med ; 81(1): 153-166, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30058162

RESUMO

PURPOSE: To develop a black blood heart-rate adaptive T2 -prepared balanced steady-state free-precession (BEATS) sequence for myocardial T2 mapping. METHODS: In BEATS, blood suppression is achieved by using a combination of preexcitation and double inversion recovery pulses. The timing and flip angles of the preexcitation pulse are auto-calculated in each patient based on heart rate. Numerical simulations, phantom studies, and in vivo studies were conducted to evaluate the performance of BEATS. BEATS T2 maps were acquired in 36 patients referred for clinical cardiac MRI and in 1 swine with recent myocardial infarction. Two readers assessed all images acquired in patients to identify the presence of artifacts associated with slow blood flow. RESULTS: Phantom experiments showed that the BEATS sequence provided accurate T2 values over a wide range of simulated heart rates. Black blood myocardial T2 maps were successfully obtained in all subjects. No significant difference was found between the average T2 measurements obtained from the BEATS and conventional bright-blood T2 ; however, there was a decrease in precision using the BEATS sequence. A suppression of the blood pool resulted in sharper definition of the blood-myocardium border and reduced partial voluming effect. The subjective assessment showed that 16% (18 out of 108) of short-axis slices have residual blood artifacts (12 in the apical slice, 4 in the midventricular slice, and 2 in the basal slice). CONCLUSION: The BEATS sequence yields dark blood myocardial T2 maps with better definition of the blood-myocardium border. Further studies are warranted to evaluate diagnostic accuracy of black blood T2 mapping.


Assuntos
Velocidade do Fluxo Sanguíneo , Imageamento por Ressonância Magnética , Miocárdio/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Animais , Artefatos , Simulação por Computador , Feminino , Coração , Frequência Cardíaca , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador , Suínos , Adulto Jovem
13.
J Cardiovasc Magn Reson ; 20(1): 66, 2018 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-30231875

RESUMO

BACKGROUND: Left bundle branch block (LBBB) is associated with abnormal left ventricular (LV) contraction, and is frequently associated with co-morbid cardiovascular disease, but the effect of an isolated (i.e. in the absence of cardiovascular dissease) LBBB on biventricular volumes and ejection fraction (EF) is not well characterized. The objective of this study was to compare LV and right ventricular (RV) volumes and EF in adults with an isolated LBBB to matched healthy controls and to population-derived normative values, using cardiovascular magnetic resonance (CMR) imaging. METHODS: We reviewed our clinical echocardiography database and the Framingham Heart Study Offspring cohort CMR database to identify adults with an isolated LBBB. Age-, sex-, hypertension-status, and body-surface area (BSA)-matched controls were identified from the Offspring cohort. All study subjects were scanned using the same CMR hardware and imaging sequence. Isolated-LBBB cases were compared with matched controls using Wilcoxon paired signed-rank test, and to normative reference values via Z-score. RESULTS: Isolated-LBBB subjects (n = 18, 10F) ranged in age from 37 to 82 years. An isolated LBBB was associated with larger LV end-diastolic and end-systolic volumes (both p < 0.01) and lower LVEF (56+/- 7% vs. 68+/- 6%; p <0.001) with similar myocardial contraction fraction. LVEF in isolated LBBB was nearly two standard deviations (Z = - 1.95) below mean sex and age-matched group values. LV stroke volume, cardiac output, and mass, and all RV parameters were similar (p = NS) between the groups. CONCLUSIONS: Adults with an isolated LBBB have greater LV volumes and markedly reduced LVEF, despite the absence of overt cardiovascular disease. These data may be useful toward the clinical interpretation of imaging studies performed on patients with an isolated LBBB.


Assuntos
Bloqueio de Ramo/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Imageamento por Ressonância Magnética , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Função Ventricular Direita , Adulto , Idoso , Idoso de 80 Anos ou mais , Bloqueio de Ramo/complicações , Bloqueio de Ramo/fisiopatologia , Estudos de Casos e Controles , Bases de Dados Factuais , Feminino , Humanos , Hipertrofia Ventricular Esquerda/etiologia , Hipertrofia Ventricular Esquerda/fisiopatologia , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Valor Preditivo dos Testes , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia
14.
J Cardiovasc Magn Reson ; 18(1): 79, 2016 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-27846845

RESUMO

BACKGROUND: Functional mitral regurgitation is one of the severe complications of non-ischemic dilated cardiomyopathy (DCM). Non-contrast native T1 mapping has emerged as a non-invasive method to evaluate myocardial fibrosis. We sought to evaluate the potential relationship between papillary muscle T1 time and mitral regurgitation in DCM patients. METHODS: Forty DCM patients (55 ± 13 years) and 20 healthy adult control subjects (54 ± 13 years) were studied. Native T1 mapping was performed using a slice interleaved T1 mapping sequence (STONE) which enables acquisition of 5 slices in the short-axis plane within a 90 s free-breathing scan. We measured papillary muscle diameter, length and shortening. DCM patients were allocated into 2 groups based on the presence or absence of functional mitral regurgitation. RESULTS: Papillary muscle T1 time was significantly elevated in DCM patients with mitral regurgitation (n = 22) in comparison to those without mitral regurgitation (n = 18) (anterior papillary muscle: 1127 ± 36 msec vs 1063 ± 16 msec, p < 0.05; posterior papillary muscle: 1124 ± 30 msec vs 1062 ± 19 msec, p < 0.05), but LV T1 time was similar (1129 ± 38 msec vs 1134 ± 58 msec, p = 0.93). Multivariate linear regression analysis showed that papillary muscle native T1 time (ß = 0.10, 95 % CI: 0.05-0.17, p < 0.05) is significantly correlated with mitral regurgitant fraction. Elevated papillary muscle T1 time was associated with larger diameter, longer length and decreased papillary muscle shortening (all p values <0.05). CONCLUSIONS: In DCM, papillary muscle native T1 time is significantly elevated and related to mitral regurgitant fraction.


Assuntos
Cardiomiopatia Dilatada/complicações , Imagem Cinética por Ressonância Magnética , Insuficiência da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Contração Miocárdica , Músculos Papilares/diagnóstico por imagem , Função Ventricular Esquerda , Adulto , Idoso , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/fisiopatologia , Estudos de Casos e Controles , Distribuição de Qui-Quadrado , Meios de Contraste/administração & dosagem , Feminino , Fibrose , Humanos , Modelos Lineares , Masculino , Meglumina/administração & dosagem , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/fisiopatologia , Análise Multivariada , Compostos Organometálicos/administração & dosagem , Músculos Papilares/patologia , Músculos Papilares/fisiopatologia , Valor Preditivo dos Testes , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo
15.
Magn Reson Med ; 74(2): 384-95, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25105469

RESUMO

PURPOSE: To evaluate the feasibility of accelerated cardiac MR (CMR) perfusion with radial sampling using nonlinear image reconstruction after exercise on an MR-compatible supine bike ergometer. METHODS: Eight healthy subjects were scanned on two separate days using radial and Cartesian CMR perfusion sequences in rest and exercise stress perfusion. Four different methods (standard gridding, conjugate gradient SENSE [CG-SENSE], nonlinear inversion with joint estimation of coil-sensitivity profiles [NLINV] and compressed sensing with a total variation constraint [TV]) were compared for the reconstruction of radial data. Cartesian data were reconstructed using SENSE. All images were assessed by two blinded readers in terms of image quality and diagnostic value. RESULTS: CG-SENSE and NLINV were scored more favorably than TV (in both rest and stress perfusion cases, P < 0.05) and gridding (for rest perfusion cases, P < 0.05). TV images showed patchy artifacts, which negatively influenced image quality especially in the stress perfusion images acquired with a low number of radial spokes. Although CG-SENSE and NLINV received better scores than Cartesian sampling in both rest and exercise stress perfusion cases, these differences were not statistically significant (P > 0.05). CONCLUSION: We have demonstrated the feasibility of accelerated CMR perfusion using radial sampling after physical exercise using a supine bicycle ergometer in healthy subjects. For reconstruction of undersampled radial perfusion, CG-SENSE and NLINV resulted in better image quality than standard gridding or TV reconstruction. Further technical improvements and clinical assessment are needed before using this approach in patients with suspected coronary artery disease.


Assuntos
Circulação Coronária/fisiologia , Vasos Coronários/fisiologia , Teste de Esforço/instrumentação , Teste de Esforço/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Adulto , Vasos Coronários/anatomia & histologia , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Masculino , Variações Dependentes do Observador , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Método Simples-Cego , Decúbito Dorsal
16.
Magn Reson Med ; 73(1): 214-22, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24554395

RESUMO

PURPOSE: To develop a three-dimensional (3D) free-breathing myocardial T1 mapping sequence for assessment of left ventricle diffuse fibrosis after contrast administration. METHODS: In the proposed sequence, multiple 3D inversion recovery images are acquired in an interleaved manner. A mixed prospective/retrospective navigator scheme is used to obtain the 3D Cartesian k-space data with fully sampled center and randomly undersampled outer k-space. The resulting undersampled 3D k-space data are then reconstructed using compressed sensing. Subsequently, T1 maps are generated by voxel-wise curve fitting of the individual interleaved images. In a phantom study, the accuracy of the 3D sequence was evaluated against two-dimensional (2D) modified Look-Locker inversion recovery (MOLLI) and spin-echo sequences. In vivo T1 times of the proposed method were compared with 2D multislice MOLLI T1 mapping. Subsequently, the feasibility of high-resolution 3D T1 mapping with spatial resolution of 1.7 × 1.7 × 4 mm(3) was demonstrated. RESULTS: The proposed method shows good agreement with 2D MOLLI and the spin-echo reference in phantom. No significant difference was found in the in vivo T1 times estimated using the proposed sequence and the 2D MOLLI technique (myocardium, 330 ± 66 ms versus 319 ± 93 ms; blood pools, 211 ± 68 ms versus 210 ± 98 ms). However, improved homogeneity, as measured using standard deviation of the T1 signal, was observed in the 3D T1 maps. CONCLUSION: The proposed sequence enables high-resolution 3D T1 mapping after contrast injection during free-breathing with volumetric left ventricle coverage.


Assuntos
Algoritmos , Ventrículos do Coração/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Disfunção Ventricular Esquerda/patologia , Adulto , Feminino , Fibrose , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Mecânica Respiratória , Sensibilidade e Especificidade
17.
NMR Biomed ; 28(1): 30-9, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25323208

RESUMO

The aim of this study was to implement and evaluate an accelerated three-dimensional (3D) cine phase contrast MRI sequence by combining a randomly sampled 3D k-space acquisition sequence with an echo planar imaging (EPI) readout. An accelerated 3D cine phase contrast MRI sequence was implemented by combining EPI readout with randomly undersampled 3D k-space data suitable for compressed sensing (CS) reconstruction. The undersampled data were then reconstructed using low-dimensional structural self-learning and thresholding (LOST). 3D phase contrast MRI was acquired in 11 healthy adults using an overall acceleration of 7 (EPI factor of 3 and CS rate of 3). For comparison, a single two-dimensional (2D) cine phase contrast scan was also performed with sensitivity encoding (SENSE) rate 2 and approximately at the level of the pulmonary artery bifurcation. The stroke volume and mean velocity in both the ascending and descending aorta were measured and compared between two sequences using Bland-Altman plots. An average scan time of 3 min and 30 s, corresponding to an acceleration rate of 7, was achieved for 3D cine phase contrast scan with one direction flow encoding, voxel size of 2 × 2 × 3 mm(3) , foot-head coverage of 6 cm and temporal resolution of 30 ms. The mean velocity and stroke volume in both the ascending and descending aorta were statistically equivalent between the proposed 3D sequence and the standard 2D cine phase contrast sequence. The combination of EPI with a randomly undersampled 3D k-space sampling sequence using LOST reconstruction allows a seven-fold reduction in scan time of 3D cine phase contrast MRI without compromising blood flow quantification.


Assuntos
Aceleração , Imagem Ecoplanar/métodos , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética/métodos , Adulto , Aorta/fisiologia , Meios de Contraste , Feminino , Humanos , Masculino
18.
Magn Reson Med ; 72(3): 689-98, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24123153

RESUMO

PURPOSE: To develop a free-breathing cardiac MR perfusion sequence with slice tracking for use after physical exercise. METHODS: We propose to use a leading navigator, placed immediately before each 2D slice acquisition, for tracking the respiratory motion and updating the slice location in real-time. The proposed sequence was used to acquire CMR perfusion datasets in 12 healthy adult subjects and 8 patients. Images were compared with the conventional perfusion (i.e., without slice tracking) results from the same subjects. The location and geometry of the myocardium were quantitatively analyzed, and the perfusion signal curves were calculated from both sequences to show the efficacy of the proposed sequence. RESULTS: The proposed sequence was significantly better compared with the conventional perfusion sequence in terms of qualitative image scores. Changes in the myocardial location and geometry decreased by 50% in the slice tracking sequence. Furthermore, the proposed sequence had signal curves that are smoother and less noisy. CONCLUSION: The proposed sequence significantly reduces the effect of the respiratory motion on the image acquisition in both rest and stress perfusion scans.


Assuntos
Doenças Cardiovasculares/fisiopatologia , Exercício Físico/fisiologia , Imageamento por Ressonância Magnética/métodos , Técnicas de Imagem de Sincronização Respiratória , Adulto , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Mecânica Respiratória
19.
Magn Reson Med ; 72(3): 850-7, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24186772

RESUMO

PURPOSE: To evaluate the feasibility of three-dimensional (3D) single breath-hold late gadolinium enhancement (LGE) of the left ventricle (LV) using supplemental oxygen and hyperventilation and compressed-sensing acceleration. METHODS: Breath-hold metrics [breath-hold duration, diaphragmatic/LV position drift, and maximum variation of R wave to R wave (RR) interval] without and with supplemental oxygen and hyperventilation were assessed in healthy adult subjects using a real-time single shot acquisition. Ten healthy subjects and 13 patients then underwent assessment of the proposed 3D breath-hold LGE acquisition (field of view = 320 × 320 × 100 mm(3) , resolution = 1.6 × 1.6 × 5.0 mm(3) , acceleration rate of 4) and a free-breathing acquisition with right hemidiaphragm navigator (NAV) respiratory gating. Semiquantitative grading of overall image quality, motion artifact, myocardial nulling, and diagnostic value was performed by consensus of two blinded observers. RESULTS: Supplemental oxygenation and hyperventilation increased the breath-hold duration (35 ± 11 s to 58 ± 21 s; P < 0.0125) without significant impact on diaphragmatic/LV position drift or maximum variation of RR interval (both P > 0.01). LGE images were of similar quality when compared with free-breathing acquisitions, but with reduced total scan time (85 ± 22 s to 35 ± 6 s; P < 0.001). CONCLUSIONS: Supplemental oxygenation and hyperventilation allow for prolonged breath-holding and enable single breath-hold 3D accelerated LGE with similar image quality as free breathing with NAV.


Assuntos
Suspensão da Respiração , Hiperventilação , Imageamento Tridimensional/métodos , Meglumina/análogos & derivados , Compostos Organometálicos/administração & dosagem , Oxigênio/administração & dosagem , Adulto , Artefatos , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste/administração & dosagem , Estudos de Viabilidade , Feminino , Voluntários Saudáveis , Humanos , Masculino , Meglumina/administração & dosagem
20.
Magn Reson Med ; 71(3): 1024-34, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23650078

RESUMO

PURPOSE: To develop arrhythmia-insensitive inversion recovery sequences for improved visualization of myocardial scar and quantification of diffuse fibrosis. METHODS: A novel preparation pre-pulse, called saturation pulse prepared heart-rate-independent inversion recovery, is introduced, which consists of a combination of saturation and inversion pulses to remove the magnetization history in each heartbeat in late gadolinium enhancement (LGE) imaging and eliminate the need for rest periods in T1 mapping. The proposed LGE and T1 mapping sequences were evaluated against conventional LGE and modified Look-Locker inversion sequences using numerical simulations, phantom and imaging in healthy subjects and patients with suspected or known cardiovascular disease. RESULTS: Simulations and phantom experiments show that the saturation pulse prepared heart-rate-independent inversion recovery pre-pulse in LGE reduces ghosting artifacts and results in perfect nulling of the healthy myocardium in the presence of arrhythmia. In T1 mapping, saturation pulse prepared heart-rate-independent inversion recovery results in (a) reduced scan time (17 vs. 9 heartbeats), (b) insensitivity to heart rate for long T1, and (c) increased signal homogeneity for short T1. LGE images in a patient in atrial fibrillation during the scan show improved myocardial nulling. In vivo T1 maps demonstrate increased signal homogeneity in blood pools and myocardium. CONCLUSION: The proposed sequences are insensitive to heart rate variability, yield improved LGE images in the presence of arrhythmias, as well as T1 mapping with shorter scan times.


Assuntos
Algoritmos , Fibrilação Atrial/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio Atordoado/patologia , Miocárdio/patologia , Adulto , Fibrilação Atrial/complicações , Fibrose , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Miocárdio Atordoado/etiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA