Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Radiol Med ; 2024 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-39287697

RESUMO

PURPOSE: Preliminary dual-energy CT studies have shown that low-energy virtual monoenergetic (VMI) + reconstructions can provide superior image quality compared to standard 120 kV CTA series. The purpose of this study is to evaluate the impact of low-energy VMI reconstructions on quantitative and qualitative image quality, vascular contrast, and diagnostic assessability of the carotid artery in patients undergoing photon-counting CTA examinations. MATERIALS AND METHODS: A total of 122 patients (67 male) who had undergone dual-source photon-counting CTA scans of the carotid artery were retrospectively analyzed in this study. Standard 120 kV CT images and low-keV VMI series from 40 to 100 keV with an interval of 15 keV were reconstructed. Quantitative analyses included the evaluation of vascular CT numbers, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). CT number measurements were performed in the common, external, and internal carotid arteries. Qualitative analyses were performed by three board-certified radiologists independently using five-point scales to evaluate image quality, vascular contrast, and diagnostic assessability of the carotid artery. RESULTS: Mean attenuation, CNR and SNR values were highest in 40 keV VMI reconstructions (HU, 1362.32 ± 457.81; CNR, 33.19 ± 12.86; SNR, 34.37 ± 12.89) followed by 55-keV VMI reconstructions (HU, 736.94 ± 150.09; CNR, 24.49 ± 7.11; SNR, 26.25 ± 7.34); all three mean values at these keV levels were significantly higher compared with the remaining VMI series and standard 120 kV CT series (HU, 154.43 ± 23.69; CNR, 16.34 ± 5.47; SNR, 24.44 ± 7.14) (p < 0.0001). The qualitative analysis showed the highest rating scores for 55 keV VMI reconstructions followed by 40 keV and 70 keV VMI series with a significant difference compared to standard 120 kV CT images series regarding image quality, vascular contrast, and diagnostic assessability of the carotid artery (all comparisons, p < 0.01). CONCLUSIONS: Low-keV VMI reconstructions at a level of 40-55 keV significantly improve image quality, vascular contrast, and the diagnostic assessability of the carotid artery compared with standard CT series in photon-counting CTA.

2.
Diagnostics (Basel) ; 14(7)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38611654

RESUMO

OBJECTIVES: The aim of this study is to evaluate the diagnostic accuracy of dual-energy computed tomography (DECT)-based Rho/Z maps in differentiating between metastases and benign liver lesions in patients diagnosed with malignant melanoma compared to conventional CT value measurements. METHODS: This retrospective study included 73 patients (mean age, 70 ± 13 years; 43 m/30 w) suffering from malignant melanoma who had undergone third-generation DECT as part of tumor staging between December 2017 and December 2021. For this study, we measured Rho (electron density) and Z (effective atomic number) values as well as Hounsfield units (HUs) in hypodense liver lesions. Values were compared, and diagnostic accuracy for differentiation was computed using receiver operating characteristic (ROC) curve analyses. Additional performed MRI or biopsies served as a standard of reference. RESULTS: A total of 136 lesions (51 metastases, 71 cysts, and 14 hemangiomas) in contrast-enhanced DECT images were evaluated. The most notable discrepancy (p < 0.001) between measured values and the highest diagnostic accuracy for distinguishing melanoma metastases from benign cysts was observed for the Z (0.992; 95% CI, 0.956-1) parameters, followed by Rho (0.908; 95% CI, 0.842-0.953) and finally HU120kV (0.829; 95% CI, 0.751-0.891). Conversely, when discriminating between liver metastases and hemangiomas, the HU120kV parameters showed the most significant difference (p < 0.001) and yielded the highest values for diagnostic accuracy (0.859; 95% CI, 0.740-0.937), followed by the Z parameters (0.790; 95% CI, 0.681-0.876) and finally the Rho values (0.621; 95% CI, 0.501-0.730). CONCLUSIONS: Rho and Z measurements derived from DECT allow for improved differentiation of liver metastases and benign liver cysts in patients with malignant melanoma compared to conventional CT value measurements. In contrast, in differentiation between liver hemangiomas and metastases, Rho/Z maps show inferior diagnostic accuracy. Therefore, differentiation between these two lesions remains a challenge for CT imaging.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA