Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Endocrinol Invest ; 42(7): 859-865, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30519958

RESUMO

PURPOSE: Chronic GC administration has numerous side effects, but little is known about the side effects of their short-term use (< 3 months)-particularly, when high doses are involved, as in the treatment of Graves' orbitopathy (GO). We investigated the effects of short-term, high-dose GC on bone turnover markers, bone mineral density (BMD), and trabecular bone scores (TBS). METHODS: Eleven patients (10 females and 1 male; median age 56 years) with active GO who were candidates for treatment with intravenous (iv) methylprednisone were consecutively enrolled. All patients were pretreated with a loading dose of 300,000 units of cholecalciferol, then given a median cumulative dose of 4.5 g (range 1.5-5.25 g) iv methylprednisone. Biochemical parameters of bone metabolism (25OHD3, PTH, P1NP, CTX and bALP) were measured at the baseline, and then 1 week and 1, 3, 6 and 12 months. BMD and TBS were obtained by X-ray absorptiometry (DXA) at the baseline and at 6 and 12 months. On DXA image, morphometric vertebral fracture assessment (VFA) was done. RESULTS: There were no significant changes in PTH, bALP or P1NP. A significant drop in CTX was seen at 1 month (down Δ49.31% from the baseline, p = 0.02), with a return to the baseline at the 3-month measurement. There was a moderate (not significant), but persistent reduction in P1NP. No changes in BMD or TBS came to light. No vertebral fractures were documented. CONCLUSIONS: Short-term, high-dose GC treatment caused a rapid, transient suppression of bone resorption, with no effects on BMD or bone micro-architecture (TBS).


Assuntos
Biomarcadores/análise , Densidade Óssea/efeitos dos fármacos , Reabsorção Óssea/prevenção & controle , Osso Esponjoso/efeitos dos fármacos , Glucocorticoides/administração & dosagem , Oftalmopatia de Graves/tratamento farmacológico , Adulto , Idoso , Reabsorção Óssea/metabolismo , Feminino , Seguimentos , Glucocorticoides/farmacologia , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Prognóstico , Estudos Prospectivos
2.
Blood Coagul Fibrinolysis ; 10(5): 245-50, 1999 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10456615

RESUMO

A new diagnostic test has recently become available which is highly specific for plasma soluble fibrin polymers, the thrombus precursor protein (TpP) enzyme immunoassay. In order to evaluate the diagnostic accuracy of this test and that of a new rapid and automated test for the determination of D-dimers, the BC D-dimer test, in patients with clinically suspected deep vein thrombosis (DVT), 70 consecutive symptomatic patients underwent laboratory analysis with both tests and with the classic enzyme-linked immunosorbent assay (ELISA) D-dimer test, followed by the execution of a compression ultrasound (CUS) test of the affected limb. Patients with a positive CUS test were considered to have DVT (20 of 70), whereas those with a serially negative test and an uneventful 3-month follow-up test were regarded as not having DVT (50 of 70). The sensitivity of the TpP test (45.0%) was significantly lower than that of both the BC D-dimer test (80.0%; P = 0.02) and the classic ELISA test (90.0%; P = 0.002). The specificity of the TpP test (66.0%) did not differ from that of either D-dimer test (60.0 and 64.0%, respectively). The negative predictive value of the TpP test (75.0%) was significantly lower than that of the classic ELISA D-dimer test (94.1%; P = 0.02), which in turn did not differ from that of the BC D-dimer test (88.2%). The positive predictive value was similarly low for each investigated test (34.6, 44.4, and 50.0%, respectively). In conclusion, the TpP test can neither be used to detect a DVT nor to exclude its development in patients with the clinical suspicion of this disease. By contrast, the BC D-dimer might safely replace the classic ELISA test for excluding DVT in symptomatic patients.


Assuntos
Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Tromboflebite/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Ensaio de Imunoadsorção Enzimática , Feminino , Fibrina/química , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Tromboflebite/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA