Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 87(4): 787-94, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26354821

RESUMO

OBJECTIVES: To evaluate the feasibility and safety of the fourth generation WATCHMAN device. BACKGROUND: The WATCHMAN left atrial appendage (LAA) closure device has been shown to be non-inferior to conventional oral anticoagulation with warfarin for stroke prevention in patients with non-valvular atrial fibrillation. A new (fourth) generation of the WATCHMAN device was designed to facilitate easier delivery and improve safety. METHODS: We conducted a prospective, non-randomized study of LAA closure with use of the 4(th) generation WATCHMAN device in 36 patients with non-valvular atrial fibrillation. Follow-up was performed at 45 days, 6 months and 12 months following implantation. RESULTS: The mean age of the population was 73 ± 6 years and 67% were male. The mean CHADS2 and CHA2 DS2-VASc Score were 2.5 and 4.5, respectively. The device was implanted successfully in 34/36 (94%). No serious hospital complications related to the device or procedure occurred. During 12 month follow-up, three ischemic strokes (8%), one hemorrhagic stroke (3%), one TIA (3%) and three deaths (9%) occurred. Device-associated thrombus formation was detected in one patient (3%) during six-month follow-up and was treated successfully with low molecular weight heparin. CONCLUSIONS: LAA closure with the 4(th) generation WATCHMAN device is feasible and safe. New technical features may contribute to a better performance of the occluder, particularly regarding the risk of pericardial effusions.


Assuntos
Apêndice Atrial , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Ataque Isquêmico Transitório/prevenção & controle , Desenho de Prótese , Implantação de Prótese/instrumentação , Acidente Vascular Cerebral/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/complicações , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Ecocardiografia Transesofagiana , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/mortalidade , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Implantação de Prótese/efeitos adversos , Implantação de Prótese/mortalidade , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 83(5): 805-10, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24259397

RESUMO

OBJECTIVES: To determine the procedural safety, safety, and efficacy of left atrial appendage (LAA) occlusion in octogenarians. BACKGROUND: Elderly patients with atrial fibrillation (AF) often do not receive appropriate anticoagulation. LAA occlusion is an option for patients with AF and contraindications to anticoagulation. Not much is known about the procedural safety and clinical efficacy of LAA occlusion in the very elderly. METHODS: A retrospective review of LAA cases at our institution between 2002 and 2013 in patients 80 years of age or older was performed. Demographic, echocardiographic, procedural, and clinical follow-up data were collected. RESULTS: Seventy-five cases were attempted in patients 80 years of age or older (average age 83.4 ± 2.8 years, 53.3% males). Hypertension, coronary artery disease, and heart failure were present in 96, 41.3, and 36%, respectively. Mean CHADS2 and CHA2DS-VASc scores were 3.3 and 5.2. Devices used included the WATCHMAN, ACP, PLAATO, Lariat, and Coherex devices, which were attempted in 34.7, 36, 17.3, 5.3, and 5.3%, respectively. Overall procedural success, safety endpoint, and 1-year device efficacy was 90.1, 3.9, and 97.4%, respectively. CONCLUSION: LAA closure is a safe and efficacious method of stroke prevention in the very elderly with AF.


Assuntos
Apêndice Atrial/fisiopatologia , Fibrilação Atrial/terapia , Cateterismo Cardíaco , Acidente Vascular Cerebral/prevenção & controle , Fatores Etários , Idoso de 80 Anos ou mais , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Desenho de Equipamento , Feminino , Alemanha , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA