Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Am Heart J ; 276: 60-69, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38996860

RESUMO

BACKGROUND: Black women with peripartum cardiomyopathy (PPCM) have a higher prevalence of hypertensive disorders of pregnancy (HDP) and worse clinical outcomes compared with non-Black women. We examined the impact of HDP on myocardial recovery in Black women with PPCM. METHODS: A total of 100 women were enrolled into the Investigation in Pregnancy Associated Cardiomyopathy (IPAC) study. Left ventricular ejection fraction (LVEF) was assessed by echocardiography at entry, 6, and 12-months post-partum (PP). Women were followed for 12 months postpartum and outcomes including persistent cardiomyopathy (LVEF ≤35%), left ventricular assist device, (LVAD), cardiac transplantation, or death were examined in subsets based on race and the presence of HDP. RESULTS: Black women with HDP were more likely to present earlier compared to Black women without HDP (days PP HDP: 34 ± 21 vs 54 ± 27 days, P = .03). There was no difference in LVEF at study entry for Black women based on HDP, but better recovery with HDP at 6 (HDP: 52 ± 11% vs no HDP: 40 ± 14%, P = .03) and 12-months (HDP:53 ± 10% vs no HDP:40 ± 16%, P = .02). At 12-months, Black women overall had a lower LVEF than non-Black women (P < .001), driven by less recovery in Black women without HDP compared to non-Black women (P < .001). In contrast, Black women with HDP had a similar LVEF at 12 months compared to non-Black women (P = .56). CONCLUSIONS: In women with PPCM, poorer outcomes evident in Black women were driven by women without a history of HDP. In Black women, a history of HDP was associated with earlier presentation and recovery which was comparable to non-Black women.

2.
Echocardiography ; 41(4): e15815, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38634182

RESUMO

BACKGROUND: Right ventricular (RV) systolic dysfunction has been identified as a prognostic marker for adverse clinical events in patients presenting with acute pulmonary embolism (PE). However, challenges exist in identifying RV dysfunction using conventional echocardiography techniques. Strain echocardiography is an evolving imaging modality which measures myocardial deformation and can be used as an objective index of RV systolic function. This study evaluated RV Global Longitudinal Strain (RVGLS) in patients with intermediate risk PE as a parameter of RV dysfunction, and compared to traditional echocardiographic and CT parameters evaluating short-term mortality. METHODS: Retrospective single center cohort study of 251 patients with intermediate-risk PE between 2010 and 2018. The primary outcome was all-cause mortality at 30 days. Statistical analysis evaluated each parameter comparing survivors versus non-survivors at 30 days. Receiver operating characteristic (ROC) curves and Kaplan-Meier curves were used for comparison of the two cohorts. RESULTS: Altogether 251 patients were evaluated. Overall mortality rate was 12.4%. Utilizing an ROC curve, an absolute cutoff value of 17.7 for RVGLS demonstrated a sensitivity of 93% and specificity of 70% for observed 30-day mortality. Individuals with an RVGLS ≤17.7 had a 25 times higher mortality rate than those with RVGLS above 17.7 (HR 25.24, 95% CI = 6.0-106.4, p < .001). Area under the curve was (.855), RVGLS outperformed traditional echocardiographic parameters, CT findings, and cardiac biomarkers on univariable and multivariable analysis. CONCLUSIONS: Reduced RVGLS values on initial echocardiographic assessment of patients with intermediate-risk PE identified patients at higher risk for mortality at 30 days.


Assuntos
Embolia Pulmonar , Disfunção Ventricular Direita , Humanos , Deformação Longitudinal Global , Estudos Retrospectivos , Estudos de Coortes , Volume Sistólico , Embolia Pulmonar/complicações , Função Ventricular Direita , Prognóstico
3.
ESC Heart Fail ; 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38984947

RESUMO

AIMS: One third of patients do not improve after cardiac resynchronization therapy (CRT). Septal flash (SF) and apical rocking (ApRock) are deformation patterns observed on echocardiography in most patients eligible for CRT. These markers of mechanical dyssynchrony have been associated to improved outcome after CRT in observational studies and may be useful to better select patients. The aim of this trial is to investigate whether the current guideline criteria for selecting patients for CRT should be modified and include SF and ApRock to improve therapy success rate, reduce excessive costs and prevent exposure to device-related complications in patients who would not benefit from CRT. METHODS: The AMEND-CRT trial is a multicentre, randomized, parallel-group, double-blind, sham-controlled trial with a non-inferiority design. The trial will include 578 patients scheduled for CRT according to the 2021 ESC guidelines who satisfy all inclusion criteria. The randomization is performed 1:1 to an active control arm ('guideline arm') or an experimental arm ('echo arm'). All participants receive a device, but in the echo arm, CRT is activated only when SF or ApRock or both are present. The outcome of both arms will be compared after 1 year. The primary outcome measures are the average change in left ventricular end-systolic volume and patient outcome assessed using a modified Packer Clinical Composite Score. CONCLUSIONS: The findings of this trial will redefine the role of echocardiography in CRT and potentially determine which patients with heart failure and a prolonged QRS duration should receive CRT, especially in patients who currently have a class IIa or class IIb recommendation.

4.
Eur J Heart Fail ; 26(4): 1078-1089, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38561314

RESUMO

AIMS: Heart failure (HF) outcomes remain poor despite optimal guideline-directed medical therapy (GDMT). We assessed safety, effectiveness, and transthoracic echocardiographic (TTE) outcomes during the 12 months after Ventura shunt implantation in the RELIEVE-HF open-label roll-in cohort. METHODS AND RESULTS: Eligibility required symptomatic HF despite optimal GDMT with ≥1 HF hospitalization in the prior year or elevated natriuretic peptides. The safety endpoint was device-related major adverse cardiovascular or neurological events at 30 days, compared to a prespecified performance goal. Effectiveness evaluations included the Kansas City Cardiomyopathy Questionnaire (KCCQ) at baseline, 1, 3, 6, and 12 months and TTE at baseline and 12 months. Overall, 97 patients were enrolled and implanted at 64 sites. Average age was 70 ± 11 years, 97% were in New York Heart Association class III, and half had left ventricular ejection fraction (LVEF) ≤40%. The safety endpoint was achieved (event rate 0%, p < 0.001). KCCQ overall summary score was improved by 12-16 points at all follow-up timepoints (all p < 0.004), with similar outcomes in patients with reduced and preserved LVEF. At 12 months, left ventricular end-systolic and end-diastolic volumes were reduced (p = 0.020 and p = 0.038, respectively), LVEF improved (p = 0.009), right ventricular end-systolic and end-diastolic areas were reduced (p = 0.001 and p = 0.030, respectively), and right ventricular fractional area change (p < 0.001) and tricuspid annular plane systolic excursion (p < 0.001) improved. CONCLUSION: Interatrial shunting with the Ventura device was safe and resulted in favourable clinical effects in patients with HF, regardless of LVEF. Improvements of left and right ventricular structure and function were consistent with reverse myocardial remodelling. These results would support the potential of this shunt device as a treatment for HF.


Assuntos
Ecocardiografia , Insuficiência Cardíaca , Volume Sistólico , Humanos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Feminino , Masculino , Idoso , Volume Sistólico/fisiologia , Ecocardiografia/métodos , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia , Átrios do Coração/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Pessoa de Meia-Idade
5.
ESC Heart Fail ; 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38773938

RESUMO

AIMS: Interatrial shunts are under evaluation as a treatment for heart failure (HF); however, their in vivo flow performance has not been quantitatively studied. We aimed to investigate the fluid dynamics properties of the 0.51 cm orifice diameter Ventura shunt and assess its lumen integrity with serial transesophageal echocardiography (TEE). METHODS AND RESULTS: Computational fluid dynamics (CFD) and bench flow tests were used to establish the flow-pressure relationship of the shunt. Open-label patients from the RELIEVE-HF trial underwent TEE at shunt implant and at 6 and 12 month follow-up. Shunt effective diameter (Deff) was derived from the vena contracta, and flow was determined by the continuity equation. CFD and bench studies independently validated that the shunt's discharge coefficient was 0.88 to 0.89. The device was successfully implanted in all 97 enrolled patients; mean age was 70 ± 11 years, 97% were NYHA class III, and 51% had LVEF ≤40%. Patency was confirmed in all instances, except for one stenotic shunt at 6 months. Deff remained unchanged from baseline at 12 months (0.47 ± 0.01 cm, P = 0.376), as did the trans-shunt mean pressure gradient (5.1 ± 3.9 mmHg, P = 0.316) and flow (1137 ± 463 mL/min, P = 0.384). TEE measured flow versus pressure closely correlated (R2 ≥ 0.98) with a fluid dynamics model. At 12 months, the pulmonary/systemic flow Qp/Qs ratio was 1.22 ± 0.12. CONCLUSIONS: When implanted in patients with advanced HF, this small interatrial shunt demonstrated predictable and durable patency and performance.

6.
Sci Transl Med ; 16(743): eadi0077, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630848

RESUMO

Peripartum cardiomyopathy (PPCM) is an idiopathic form of pregnancy-induced heart failure associated with preeclampsia. Circulating factors in late pregnancy are thought to contribute to both diseases, suggesting a common underlying pathophysiological process. However, what drives this process remains unclear. Using serum proteomics, we identified the senescence-associated secretory phenotype (SASP), a marker of cellular senescence associated with biological aging, as the most highly up-regulated pathway in young women with PPCM or preeclampsia. Placentas from women with preeclampsia displayed multiple markers of amplified senescence and tissue aging, as well as overall increased gene expression of 28 circulating proteins that contributed to SASP pathway enrichment in serum samples from patients with preeclampsia or PPCM. The most highly expressed placental SASP factor, activin A, was associated with cardiac dysfunction or heart failure severity in women with preeclampsia or PPCM. In a murine model of PPCM induced by cardiomyocyte-specific deletion of the gene encoding peroxisome proliferator-activated receptor γ coactivator-1α, inhibiting activin A signaling in the early postpartum period with a monoclonal antibody to the activin type II receptor improved heart function. In addition, attenuating placental senescence with the senolytic compound fisetin in late pregnancy improved cardiac function in these animals. These findings link senescence biology to cardiac dysfunction in pregnancy and help to elucidate the pathogenesis underlying cardiovascular diseases of pregnancy.


Assuntos
Cardiomiopatias , Cardiopatias , Insuficiência Cardíaca , Pré-Eclâmpsia , Humanos , Gravidez , Feminino , Camundongos , Animais , Período Periparto , Placenta , Fatores de Transcrição
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA