Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 17: 152, 2016 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-27060078

RESUMO

BACKGROUND: Animal models serve as an important tool to understand peri-implant infection. Most of the models use high bacterial loads (>10(4) colony forming units, CFU) to provide high infection rates. Therefore these animals evolve rather similarly, making comparison between groups and statistical analysis possible. On the other hand, to mimic clinical constellation of surgery-related infections the use of low amounts of bacteria would be more advantageous. METHODS: We developed a metaphyseal rat model of peri-implant bone infection with low amount of bacterial loads (10(2) and 10(3) CFU of Staphylococcus aureus) and investigated osseointegration of the implants coated with hydroxyapatite (HA) and low-dosed HA-silver (HA-Ag). Non-infected implants served as controls. After 6 weeks rats were sacrificed and implants evaluated for osseointegration and infection. RESULTS: Infection of implanted devices was reliably induced, independently whether 10(2) or 10(3) CFU of S. aureus were inoculated and HA or HA-Ag coated implants were used. No systemic infection was present in any of the animals at the time of sacrifice, and no animal developed acute infection requiring premature sacrifice. All CFU counts of the implant and the bone at sacrifice were significantly higher than the inoculated load (p < .05). All sterilely inserted implants showed excellent osseointegration and no infection. CONCLUSIONS: Our present study of a rat tibia model reliably induced osteomyelitis in the metaphysis with low-doses of bacteria. The addition of low-dosed Ag to the implant coating was not able to reduce the infection rates. The results demonstrate that it is possible to develop a model of implant-related osteomyelitis in rats with low amounts of bacteria to better mimic clinical constellations. No other promoters of infection besides insertion of the screw implant were used in this model.


Assuntos
Parafusos Ósseos/microbiologia , Modelos Animais de Doenças , Osteomielite/diagnóstico por imagem , Infecções Estafilocócicas/diagnóstico por imagem , Staphylococcus aureus , Animais , Parafusos Ósseos/efeitos adversos , Masculino , Osteomielite/etiologia , Osteomielite/patologia , Ratos , Ratos Wistar , Infecções Estafilocócicas/complicações , Infecções Estafilocócicas/patologia
3.
J Appl Biomater Funct Mater ; 14(4): e441-e448, 2016 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-27647385

RESUMO

BACKGROUND: Silver ions (Ag+) have strong antibacterial effects, and silver-coated materials are in widespread clinical use. However, the application of silver-coated medical devices is not without concerns: its use with direct bone contact is not established, and systemic toxic side effects of released Ag+ have been described. Therefore, alternative bactericidal coatings with a more localized way of acting - e.g., calcium dihydroxide, Ca(OH)2 (CH) - would be advantageous. METHODS: A new rat model of the animal's tibial metaphysis was developed. In the left proximal tibiae of 36 male Wistar rats, titanium screws were implanted. The screws were coated with hydroxyapatite (HA; 12 animals: group I), low-dosed HA silver (HA-Ag; 12 animals: group II) and CH (12 animals: group III). After 6 weeks, all rats were sacrificed. The implants were evaluated for morphological changes on their surfaces, by light microscopy, scanning electron microscopy and energy-dispersive X-ray spectroscopy; for osteointegration, by measurement of resistance to removal; and for bacterial colonization, by quantitative culture analysis. Additionally, the tibial bone was investigated histologically for signs of osteomyelitis and sonicated to detect bacterial loads. RESULTS: (i) No microbiological or histological signs of infection could be determined on any of the screws or the surrounding bone. (ii) The bone-implant interface analysis revealed extensive bone formation and direct bone-implant contact on all HA, HA-Ag and HA-CH coated screws. (iii) HA and HA-Ag were partially, and CH was fully, degraded on the screw coating, allowing host bone to osteointegrate.


Assuntos
Parafusos Ósseos , Hidróxido de Cálcio/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Prata/farmacologia , Tíbia/metabolismo , Animais , Masculino , Ratos , Ratos Wistar , Tíbia/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA