RESUMO
OBJECTIVES: To determine a level of oxygen desaturation from baseline that is associated with increased risk of tracheal intubation associated events in children with cyanotic and noncyanotic heart disease. DESIGN: Retrospective analysis of prospectively collected data from the National Emergency Airway Registry for Children, an international multicenter quality improvement collaborative for airway management in critically ill children. SETTING: Thirty-eight PICUs from July 2012 to December 2016. PATIENTS: Children with cyanotic and noncyanotic heart disease who underwent tracheal intubation in a pediatric or cardiac ICU. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Our exposure of interest was oxygen desaturation measured by a fall in pulse oximetry from baseline after preoxygenation. Primary outcome was the occurrence of hemodynamic tracheal intubation associated events defined as cardiac arrest, hypotension or dysrhythmia. One-thousand nine-hundred ten children (cyanotic, 999; noncyanotic, 911) were included. Patients with cyanotic heart disease who underwent tracheal intubations were younger (p < 0.001) with higher Pediatric Index of Mortality 2 scores (p < 0.001), more likely to have a cardiac surgical diagnosis (p < 0.001), and less likely to have hemodynamic instability (p = 0.009) or neurologic failure as an indication (p = 0.008). Oxygen desaturation was observed more often in children with cyanotic versus noncyanotic heart disease (desaturation of 15% to < 30%: 23% vs 16%, desaturation ≥ 30%: 23% vs 17%; p < 0.001), with no significant difference in occurrence of hemodynamic tracheal intubation associated events (7.5% vs 6.9%; p = 0.618). After adjusting for confounders, oxygen desaturation by 30% or more is associated with increased odds for adverse hemodynamic events (odds ratio, 4.03; 95% CI, 2.12-7.67) for children with cyanotic heart disease and (odds ratio, 3.80; 95% CI, 1.96-7.37) for children with noncyanotic heart disease. CONCLUSIONS: Oxygen desaturation was more commonly observed during tracheal intubation in children with cyanotic versus noncyanotic heart disease. However, hemodynamic tracheal intubation associated event rates were similar. In both groups, oxygen desaturation greater than or equal to 30% was significantly associated with increased occurrence of hemodynamic tracheal intubation associated events.
Assuntos
Cianose/fisiopatologia , Cardiopatias/fisiopatologia , Hemodinâmica/fisiologia , Intubação Intratraqueal/estatística & dados numéricos , Oxigênio/sangue , Adolescente , Fatores Etários , Arritmias Cardíacas/etiologia , Criança , Pré-Escolar , Estado Terminal , Cianose/epidemiologia , Feminino , Parada Cardíaca/etiologia , Cardiopatias/epidemiologia , Humanos , Hipotensão/etiologia , Lactente , Recém-Nascido , Unidades de Terapia Intensiva Pediátrica , Intubação Intratraqueal/efeitos adversos , Masculino , Oximetria , Estudos RetrospectivosRESUMO
INTRODUCTION: Reliable predictors of extubation readiness are needed and may reduce morbidity related to extubation failure. We aimed to examine the relationship between changes in pre-extubation near-infrared spectroscopy measurements from baseline and extubation outcomes after neonatal cardiac surgery. MATERIALS AND METHODS: In this retrospective cross-sectional multi-centre study, a secondary analysis of prospectively collected data from neonates who underwent cardiac surgery at seven tertiary-care children's hospitals in 2015 was performed. Extubation failure was defined as need for re-intubation within 72 hours of the first planned extubation attempt. Near-infrared spectroscopy measurements obtained before surgery and before extubation in patients who failed extubation were compared to those of patients who extubated successfully using t-tests. RESULTS: Near-infrared spectroscopy measurements were available for 159 neonates, including 52 with single ventricle physiology. Median age at surgery was 6 days (range: 1-29 days). A total of 15 patients (9.4 %) failed extubation. Baseline cerebral and renal near-infrared spectroscopy measurements were not statistically different between those who were successfully extubated and those who failed, but pre-extubation cerebral and renal values were significantly higher in neonates who extubated successfully. An increase from baseline to time of extubation values in cerebral oximetry saturation by ≥ 5 % had a positive predictive value for extubation success of 98.6 % (95%CI: 91.1-99.8 %). CONCLUSION: Pre-extubation cerebral near-infrared spectroscopy measurements, when compared to baseline, were significantly associated with extubation outcomes. These findings demonstrate the potential of this tool as a valuable adjunct in assessing extubation readiness after paediatric cardiac surgery and warrant further evaluation in a larger prospective study.
Assuntos
Extubação , Procedimentos Cirúrgicos Cardíacos , Circulação Cerebrovascular/fisiologia , Cuidados Pós-Operatórios/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Estudos Transversais , Feminino , Cardiopatias Congênitas/cirurgia , Humanos , Recém-Nascido , Masculino , Oximetria , Valor Preditivo dos Testes , Estudos Retrospectivos , Falha de Tratamento , Desmame do Respirador/métodosRESUMO
OBJECTIVES: Cricoid pressure is often used to prevent regurgitation during induction and mask ventilation prior to high-risk tracheal intubation in critically ill children. Clinical data in children showing benefit are limited. Our objective was to evaluate the association between cricoid pressure use and the occurrence of regurgitation during tracheal intubation for critically ill children in PICU. DESIGN: A retrospective cohort study of a multicenter pediatric airway quality improvement registry. SETTINGS: Thirty-five PICUs within general and children's hospitals (29 in the United States, three in Canada, one in Japan, one in Singapore, and one in New Zealand). PATIENTS: Children (< 18 yr) with initial tracheal intubation using direct laryngoscopy in PICUs between July 2010 and December 2015. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Multivariable logistic regression analysis was used to evaluate the association between cricoid pressure use and the occurrence of regurgitation while adjusting for underlying differences in patient and clinical care factors. Of 7,825 events, cricoid pressure was used in 1,819 (23%). Regurgitation was reported in 106 of 7,825 (1.4%) and clinical aspiration in 51 of 7,825 (0.7%). Regurgitation was reported in 35 of 1,819 (1.9%) with cricoid pressure, and 71 of 6,006 (1.2%) without cricoid pressure (unadjusted odds ratio, 1.64; 95% CI, 1.09-2.47; p = 0.018). On multivariable analysis, cricoid pressure was not associated with the occurrence of regurgitation after adjusting for patient, practice, and known regurgitation risk factors (adjusted odds ratio, 1.57; 95% CI, 0.99-2.47; p = 0.054). A sensitivity analysis in propensity score-matched cohorts showed cricoid pressure was associated with a higher regurgitation rate (adjusted odds ratio, 1.01; 95% CI, 1.00-1.02; p = 0.036). CONCLUSIONS: Cricoid pressure during induction and mask ventilation before tracheal intubation in the current ICU practice was not associated with a lower regurgitation rate after adjusting for previously reported confounders. Further studies are needed to determine whether cricoid pressure for specific indication with proper maneuver would be effective in reducing regurgitation events.
Assuntos
Cartilagem Cricoide/fisiopatologia , Estado Terminal/terapia , Intubação Intratraqueal/efeitos adversos , Refluxo Laringofaríngeo/epidemiologia , Canadá , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Humanos , Lactente , Unidades de Terapia Intensiva Pediátrica , Intubação Intratraqueal/métodos , Japão , Refluxo Laringofaríngeo/etiologia , Refluxo Laringofaríngeo/prevenção & controle , Laringoscopia/efeitos adversos , Masculino , Nova Zelândia , Pressão , Pontuação de Propensão , Melhoria de Qualidade , Sistema de Registros , Estudos Retrospectivos , Singapura , Estados UnidosRESUMO
OBJECTIVES: External laryngeal manipulation is a commonly used maneuver to improve visualization of the glottis during tracheal intubation in children. However, the effectiveness to improve tracheal intubation attempt success rate in the nonanesthesia setting is not clear. The study objective was to evaluate the association between external laryngeal manipulation use and initial tracheal intubation attempt success in PICUs. DESIGN: A retrospective observational study using a multicenter emergency airway quality improvement registry. SETTING: Thirty-five PICUs within general and children's hospitals (29 in the United States, three in Canada, one in Japan, one in Singapore, and one in New Zealand). PATIENTS: Critically ill children (< 18 years) undergoing initial tracheal intubation with direct laryngoscopy in PICUs between July 1, 2010, and December 31, 2015. MEASUREMENTS AND MAIN RESULTS: Propensity score-matched analysis was performed to evaluate the association between external laryngeal manipulation and initial attempt success while adjusting for underlying differences in patient and clinical care factors: age, obesity, tracheal intubation indications, difficult airway features, provider training level, and neuromuscular blockade use. External laryngeal manipulation was defined as any external force to the neck during laryngoscopy. Of the 7,825 tracheal intubations, the initial tracheal intubation attempt was successful in 1,935/3,274 intubations (59%) with external laryngeal manipulation and 3,086/4,551 (68%) without external laryngeal manipulation (unadjusted odds ratio, 0.69; 95% CI, 0.62-0.75; p < 0.001). In propensity score-matched analysis, external laryngeal manipulation remained associated with lower initial tracheal intubation attempt success (adjusted odds ratio, 0.93; 95% CI, 0.90-0.95; p < 0.001). CONCLUSIONS: External laryngeal manipulation during direct laryngoscopy was associated with lower initial tracheal intubation attempt success in critically ill children, even after adjusting for underlying differences in patient factors and provider levels. The indiscriminate use of external laryngeal manipulation cannot be recommended.
Assuntos
Estado Terminal/terapia , Intubação Intratraqueal/métodos , Laringoscopia/métodos , Canadá , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Unidades de Terapia Intensiva Pediátrica , Japão , Laringe , Masculino , Nova Zelândia , Pontuação de Propensão , Melhoria de Qualidade , Sistema de Registros , Estudos Retrospectivos , Singapura , Estados UnidosRESUMO
OBJECTIVES: Evaluate differences in tracheal intubation-associated events and process variances (i.e., multiple intubation attempts and oxygen desaturation) between pediatric cardiac ICUs and noncardiac PICUs in children with underlying cardiac disease. DESIGN: Retrospective cohort study using a multicenter tracheal intubation quality improvement database (National Emergency Airway Registry for Children). SETTING: Thirty-six PICUs (five cardiac ICUs, 31 noncardiac ICUs) from July 2012 to March 2016. PATIENTS: Children with medical or surgical cardiac disease who underwent intubation in an ICU. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Our primary outcome was the rate of any adverse tracheal intubation-associated event. Secondary outcomes were severe tracheal intubation-associated events, multiple tracheal intubation attempt rates, and oxygen desaturation. There were 1,502 tracheal intubations in children with underlying cardiac disease (751 in cardiac ICUs, 751 in noncardiac ICUs) reported. Cardiac ICUs and noncardiac ICUs had similar proportions of patients with surgical cardiac disease. Patients undergoing intubation in cardiac ICUs were younger (median age, 1 mo [interquartile range, 0-6 mo]) compared with noncardiac ICUs (median 3 mo [interquartile range, 1-11 mo]; p < 0.001). Tracheal intubation-associated event rates were not different between cardiac ICUs and noncardiac ICUs (16% vs 19%; adjusted odds ratio, 0.74; 95% CI, 0.54-1.02; p = 0.069). However, in a sensitivity analysis comparing cardiac ICUs with mixed ICUs (i.e., ICUs caring for children with either general pediatric or cardiac diseases), cardiac ICUs had decreased odds of adverse events (adjusted odds ratio, 0.71; 95% CI, 0.52-0.97; p = 0.033). Rates of severe tracheal intubation-associated events and multiple attempts were similar. Desaturations occurred more often during intubation in cardiac ICUs (adjusted odds ratio, 1.61; 95% CI, 1.04-1.15; p = 0.002). CONCLUSIONS: In children with underlying cardiac disease, rates of adverse tracheal intubation-associated events were not lower in cardiac ICUs as compared to noncardiac ICUs, even after adjusting for differences in patient characteristics and care models.
Assuntos
Estado Terminal/terapia , Cardiopatias/terapia , Unidades de Terapia Intensiva Pediátrica/estatística & dados numéricos , Intubação Intratraqueal/efeitos adversos , Padrões de Prática Médica/estatística & dados numéricos , Adolescente , Criança , Pré-Escolar , Estudos de Coortes , Bases de Dados Factuais , Feminino , Humanos , Lactente , Recém-Nascido , Intubação Intratraqueal/estatística & dados numéricos , Masculino , Oximetria/estatística & dados numéricos , Melhoria de Qualidade , Estudos RetrospectivosRESUMO
IntroductionChildren with CHD and acquired heart disease have unique, high-risk physiology. They may have a higher risk of adverse tracheal-intubation-associated events, as compared with children with non-cardiac disease.Materials and methodsWe sought to evaluate the occurrence of adverse tracheal-intubation-associated events in children with cardiac disease compared to children with non-cardiac disease. A retrospective analysis of tracheal intubations from 38 international paediatric ICUs was performed using the National Emergency Airway Registry for Children (NEAR4KIDS) quality improvement registry. The primary outcome was the occurrence of any tracheal-intubation-associated event. Secondary outcomes included the occurrence of severe tracheal-intubation-associated events, multiple intubation attempts, and oxygen desaturation. RESULTS: A total of 8851 intubations were reported between July, 2012 and March, 2016. Cardiac patients were younger, more likely to have haemodynamic instability, and less likely to have respiratory failure as an indication. The overall frequency of tracheal-intubation-associated events was not different (cardiac: 17% versus non-cardiac: 16%, p=0.13), nor was the rate of severe tracheal-intubation-associated events (cardiac: 7% versus non-cardiac: 6%, p=0.11). Tracheal-intubation-associated cardiac arrest occurred more often in cardiac patients (2.80 versus 1.28%; p<0.001), even after adjusting for patient and provider differences (adjusted odds ratio 1.79; p=0.03). Multiple intubation attempts occurred less often in cardiac patients (p=0.04), and oxygen desaturations occurred more often, even after excluding patients with cyanotic heart disease. CONCLUSIONS: The overall incidence of adverse tracheal-intubation-associated events in cardiac patients was not different from that in non-cardiac patients. However, the presence of a cardiac diagnosis was associated with a higher occurrence of both tracheal-intubation-associated cardiac arrest and oxygen desaturation.