Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 32(12): 8597-8607, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35612663

RESUMO

OBJECTIVES: 4D flow MRI enables quantitative assessment of helical flow. We sought to generate normal values and elucidate changes of helical flow (duration, volume, length, velocities and rotational direction) and flow jet (displacement, flow angle) as well as wall shear stress (WSS). METHODS: We assessed the temporal helical existence (THEX), maximum helical volume (HVmax), accumulated helical volume (HVacc), accumulated helical volume length (HVLacc), maximum forward velocity (maxVfor), maximum circumferential velocity (maxVcirc), rotational direction (RD) and maximum wall shear stress (WSS) as reported elsewhere using the software tool Bloodline in 86 healthy volunteers (46 females, mean age 41 ± 13 years). RESULTS: WSS decreased by 42.1% and maxVfor by 55.7% across age. There was no link between age and gender regarding the other parameters. CONCLUSION: This study provides age-dependent normal values regarding WSS and maxVfor and age- and gender-independent normal values regarding THEX, HVmax, HVacc, HVLacc, RD and maxVcirc. KEY POINTS: • 4D flow provides numerous new parameters; therefore, normal values are mandatory. • Wall shear stress decreases over age. • Maximum helical forward velocity decreases over age.


Assuntos
Aorta , Hemodinâmica , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Velocidade do Fluxo Sanguíneo , Valores de Referência , Voluntários Saudáveis , Estresse Mecânico
2.
Eur Radiol ; 29(7): 3686-3695, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31041566

RESUMO

OBJECTIVES: To assess the incidence of acute adverse events (AAEs) in gadolinium-enhanced cardiac magnetic resonance (CMR) imaging. METHODS: Gadolinium-based contrast agent (GBCA)-enhanced CMR data from the multinational, multicenter European Society of Cardiovascular Radiology MRCT Registry was included. AAE severity was classified according to the American College of Radiology Manual on Contrast Media (mild, moderate, severe). Multivariable generalized linear mixed effect models were used to assess the likelihood of AAEs in various GBCA, adjusting for pharmacological stressor, main indications (i.e., suspected or known coronary artery disease or myocarditis), age, sex, and submitting center as a random effect. RESULTS: In the study population of 72,839 GBCA-enhanced CMRs, a total of 260 AAEs were reported (0.36%), with a minority of severe AAEs (n = 24, 0.033%). Allergic-like AAEs were less likely than physiologic AAEs (29% versus 71%). Patients without pharmacological stress imaging had a lower AAE rate (0.22%) compared to stress imaging (0.75%), with the highest AAE rates for regadenoson (2.95%). AAE rates also varied by GBCA subtype (overall p < 0.001). There was significant interaction between GBCA and pharmacological stressor (interaction p = 0.025), with AAE rates ranging between 0 and 10% for certain GBCA/stressor combinations. There was further marginal evidence that higher GBCA volume was associated with higher AAE incidence (OR = 1.02, p = 0.05). CONCLUSION: GBCA-enhanced CMR imaging demonstrates low AAE rates comparable to those of other body regions. AAE likelihood correlates with GBCA subtype, pharmacological stressor, and imaging indication. Intravenous fluid administration in patients with cardiac impairment might contribute to these findings. KEY POINTS: • Acute adverse event rates in cardiac magnetic resonance (CMR) imaging with gadolinium-based contrast agents (GBCAs) are low (0.36%), especially for severe adverse events (0.033%). • Mild and moderate adverse events are more frequent during stress CMR imaging. • Physiologic AAEs are more common than allergic AAEs in CMR imaging.


Assuntos
Doenças Cardiovasculares/diagnóstico , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/etiologia , Imagem Cinética por Ressonância Magnética/efeitos adversos , Compostos Organometálicos/efeitos adversos , Radiologia , Sistema de Registros , Sociedades Médicas , Doença Aguda , Administração Intravenosa , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/epidemiologia , Europa (Continente)/epidemiologia , Feminino , Humanos , Incidência , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos/administração & dosagem , Estudos Retrospectivos
3.
BMC Pregnancy Childbirth ; 19(1): 160, 2019 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-31068180

RESUMO

BACKGROUND: Prenatal risk stratification of women with previous cesarean section (CS) by ultrasound thickness measurement of the lower uterine segment (LUS) is challenging. There is a wide range of proposed cutoff values and a valuable algorithm for selection before birth is not available. Using 3 T magnetic resonance imaging (MRI), we aimed to identify possible shortcomings of the current protocols used for birth selection after CS. Therefore, we evaluated anatomic and morphologic differences of the LUS and its thickness in patients with CS and those without. Possible impact factors on LUS thickness were studied. METHODS: We retrospectively analyzed 3 T MRI scans of 164 pregnant women in their second or third trimester, with (patient group, n = 60) and without previous CS (control group, n = 104). Sagittal T2-weighted images were studied. Normal findings of the LUS in MRI, reliability of MRI measurements, as well as factors influencing LUS thickness were assessed. MRI findings were compared to intraoperative findings. RESULTS: MRI provided good intra- (ICC 0.872) and fair inter-rater reliability (ICC 0.643). The relationship of the LUS and the cesarean scar to the surrounding anatomical structures and also its morphology varied strongly in patients and controls. Scar identification was possible in only 9/60 (15.0%) patients. The LUS was thinner in patients (1.9 ± 0.7 mm) than in controls (2.7 ± 1.3 mm). An LUS thinning up to 1 mm was observed in 23% of women without a previous CS and in 34% of women with normal intraoperative findings. Suspicion of a uterine dehiscence (LUS thickness < 1 mm) was only found in the patient group (5/59 (8.5%)) and was intraoperatively confirmed. In controls, LUS thickness was influenced by fetal weight, gestational age and amniotic fluid amounts. CONCLUSION: Variability in anatomy, thickness and morphology seem to limit common prenatal LUS imaging diagnostics. Therefore, we consider that diagnostic protocols must be re-evaluated and imaging should be adjusted to the individual patient conditions. Due to its independency of ultrasound limitations, an additional MRI might be useful for altered anatomy and impaired ultrasound conditions. An LUS thinning up to 1 mm might be a normal finding and should be further investigated as reference value.


Assuntos
Cesárea , Imageamento por Ressonância Magnética , Útero/anatomia & histologia , Útero/diagnóstico por imagem , Adulto , Cesárea/efeitos adversos , Cicatriz/diagnóstico por imagem , Cicatriz/etiologia , Feminino , Peso Fetal , Idade Gestacional , Humanos , Imageamento por Ressonância Magnética/métodos , Tamanho do Órgão , Seleção de Pacientes , Gravidez , Estudos Retrospectivos , Medição de Risco
4.
Arch Gynecol Obstet ; 299(2): 439-449, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30519750

RESUMO

PURPOSE: Uterine rupture during labor is a rare but life-threatening complication after previous cesarean section (CS). Prenatal risk is assessed using ultrasound thickness measurement of the lower uterine segment (LUS). Due to inhomogeneous study results, however, clinical obstetrics still lacks for standard protocols and reliable reference values. As 3 T magnetic resonance imaging (MRI) has not yet been sufficiently studied regarding LUS diagnostics after previous CS, we sought to evaluate its feasibility focusing on thickness measurements and typical characteristics of the CS-scar region in comparison to ultrasound and the intraoperative status. METHODS: In this prospective study, 25 asymptomatic patients with one previous CS and inconspicuous ultrasound findings were included. An additional 3 T MRI with either a T2-weighted Turbo-Spin-Echo or a Half Fourier-Acquired-Single-shot-Turbo-spin-Echo sequence in a sagittal orientation was performed. We analyzed categorical image quality, inter- and intra-rater reliability as well as anatomy, morphology and thickness of the LUS. Results were compared to ultrasound and intraoperative findings. RESULTS: MRI provided good to excellent image quality in all patients. The imaged structures presented with a high variability in anatomy and morphology. Image characteristics indicating the uterine scar were only found in 11/25 (44%) patients. LUS thickness measurements with MRI showed good inter- and intra-rater reliability but poor agreement with ultrasound. CONCLUSIONS: MRI is appropriate for additional LUS diagnostics in patients with previous CS. The strong individual variability of LUS-anatomy and morphology might explain the difficulties in establishing uniform diagnostic standards after CS.


Assuntos
Cesárea/instrumentação , Cicatriz/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ultrassonografia/métodos , Ruptura Uterina/diagnóstico por imagem , Adulto , Feminino , Humanos , Gravidez , Estudos Prospectivos
5.
Eur Radiol ; 27(5): 1954-1962, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27553931

RESUMO

OBJECTIVES: To evaluate the feasibility of performing comprehensive Cardiac Magnetic resonance (CMR) guided electrophysiological (EP) interventions in a porcine model encompassing left atrial access. METHODS: After introduction of two femoral sheaths 14 swine (41 ± 3.6 kg) were transferred to a 1.5 T MR scanner. A three-dimensional whole-heart sequence was acquired followed by segmentation and the visualization of all heart chambers using an image-guidance platform. Two MR conditional catheters were inserted. The interventional protocol consisted of intubation of the coronary sinus, activation mapping, transseptal left atrial access (n = 4), generation of ablation lesions and eventually ablation of the atrioventricular (AV) node. For visualization of the catheter tip active tracking was used. Catheter positions were confirmed by passive real-time imaging. RESULTS: Total procedure time was 169 ± 51 minutes. The protocol could be completed in 12 swine. Two swine died from AV-ablation induced ventricular fibrillation. Catheters could be visualized and navigated under active tracking almost exclusively. The position of the catheter tips as visualized by active tracking could reliably be confirmed with passive catheter imaging. CONCLUSIONS: Comprehensive CMR-guided EP interventions including left atrial access are feasible in swine using active catheter tracking. KEY POINTS: • Comprehensive CMR-guided electrophysiological interventions including LA access were conducted in swine. • Active catheter-tracking allows efficient catheter navigation also in a transseptal approach. • More MR-conditional tools are needed to facilitate left atrial interventions in humans.


Assuntos
Técnicas Eletrofisiológicas Cardíacas/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Animais , Catéteres , Átrios do Coração , Imageamento por Ressonância Magnética/métodos , Suínos
6.
Europace ; 18(4): 572-7, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26316146

RESUMO

AIMS: Recently cardiac magnetic resonance (CMR) imaging has been found feasible for the visualization of the underlying substrate for cardiac arrhythmias as well as for the visualization of cardiac catheters for diagnostic and ablation procedures. Real-time CMR-guided cavotricuspid isthmus ablation was performed in a series of six patients using a combination of active catheter tracking and catheter visualization using real-time MR imaging. METHODS AND RESULTS: Cardiac magnetic resonance utilizing a 1.5 T system was performed in patients under deep propofol sedation. A three-dimensional-whole-heart sequence with navigator technique and a fast automated segmentation algorithm was used for online segmentation of all cardiac chambers, which were thereafter displayed on a dedicated image guidance platform. In three out of six patients complete isthmus block could be achieved in the MR scanner, two of these patients did not need any additional fluoroscopy. In the first patient technical issues called for a completion of the procedure in a conventional laboratory, in another two patients the isthmus was partially blocked by magnetic resonance imaging (MRI)-guided ablation. The mean procedural time for the MR procedure was 109 ± 58 min. The intubation of the CS was performed within a mean time of 2.75 ± 2.21 min. Total fluoroscopy time for completion of the isthmus block ranged from 0 to 7.5 min. CONCLUSION: The combination of active catheter tracking and passive real-time visualization in CMR-guided electrophysiologic (EP) studies using advanced interventional hardware and software was safe and enabled efficient navigation, mapping, and ablation. These cases demonstrate significant progress in the development of MR-guided EP procedures.


Assuntos
Flutter Atrial/cirurgia , Função do Átrio Direito , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Átrios do Coração/cirurgia , Imagem por Ressonância Magnética Intervencionista , Adulto , Idoso , Algoritmos , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Sedação Profunda/métodos , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Fluoroscopia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Humanos , Hipnóticos e Sedativos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Valor Preditivo dos Testes , Propofol , Fatores de Tempo , Resultado do Tratamento
7.
Cardiol Young ; 25(7): 1268-75, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25382031

RESUMO

OBJECTIVE: To test the hypothesis that myocardial scars after repair of tetralogy of Fallot are related to impaired cardiac function and adverse clinical outcome. METHODS: A total of 53 patients were retrospectively analysed after repair of tetralogy of Fallot. The median patient age was 20 years (range 2-48). Cardiac MRI with a 1.5 T magnet included cine sequences to obtain volumes and function, phase-sensitive inversion recovery delayed enhancement imaging to detect myocardial scars, and flow measurements to determine pulmonary regurgitation fraction. In addition, clinical parameters were obtained. RESULTS: An overall 83% of patients were in NYHA class I. All patients with the exception of 2 (96%) had pulmonary insufficiency. Mean ejection fraction and end-diastolic volume index were 46% and 128 ml/m2 for the right ventricle and 54% and 82 ml/m² for the left ventricle, respectively. Excluding enhancement of the septal insertion and prosthetic patches, delayed enhancement was seen in 11/53 cases (21%). Delayed enhancement of the right ventricle was detected in 6/53 patients (11%) and of the left ventricle in 5/53 patients (9%). The patient group with delayed enhancement was significantly older (p=0.003), had later repair (p=0.007), and higher left ventricular myocardial mass index (p=0.009) compared with the group without delayed enhancement. CONCLUSIONS: This study reveals that scarring is common in patients after surgical repair of tetralogy of Fallot and is associated with older age and late repair. However, there was no difference in right ventricular function, NYHA class, or occurrence of clinically relevant arrhythmias between patients with and those without myocardial scars.


Assuntos
Cicatriz/fisiopatologia , Ventrículos do Coração/fisiopatologia , Complicações Pós-Operatórias/fisiopatologia , Insuficiência da Valva Pulmonar/cirurgia , Tetralogia de Fallot/diagnóstico , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Direita/fisiopatologia , Adolescente , Adulto , Procedimentos Cirúrgicos Cardíacos/métodos , Criança , Pré-Escolar , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Estudos Retrospectivos , Adulto Jovem
8.
Radiology ; 271(3): 695-702, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24484059

RESUMO

PURPOSE: To assess if real-time magnetic resonance (MR) imaging-guided radiofrequency (RF) ablation for atrial flutter is feasible in patients. MATERIALS AND METHODS: The study complied with the Declaration of Helsinki and was approved by the local ethics committee. All patients were informed about the investigational nature of the procedures and provided written informed consent. Ten patients (six men; mean age ± standard deviation, 68 years ± 10) with symptomatic atrial flutter underwent isthmus ablation. In all patients, two MR imaging conditional steerable diagnostic and ablation catheters were inserted into the coronary sinus via femoral sheaths and into the right atrium with fluoroscopic guidance. The patients were then transferred to a 1.5-T whole-body MR imager for an ablation procedure, in which the catheters were manipulated by an electrophysiologist by using a commercially available interactive real-time steady-state free precession MR imaging sequence. RESULTS: All catheters were placed in standard positions successfully. Furthermore, simple programmed stimulation maneuvers were performed. In one of 10 patients, a complete conduction block was performed with MR imaging guidance. In nine of 10 patients, creating only a small number of additional touch-up lesions was necessary to complete the isthmus block with conventional fluoroscopy (median, three lesions; interquartile range, two to four lesions). CONCLUSION: Real-time MR imaging-guided placement of multiple catheters is feasible in patients, with subsequent performance of stimulation maneuvers and occasional complete isthmus ablation.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Imagem por Ressonância Magnética Intervencionista , Idoso , Flutter Atrial/fisiopatologia , Meios de Contraste , Eletrocardiografia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Compostos Organometálicos
9.
Eur Radiol ; 24(10): 2360-71, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24895035

RESUMO

OBJECTIVE: Comparing the diagnostic value of multi-sequential cardiac magnetic resonance imaging (CMR) with endomyocardial biopsy (EMB) for sub-clinical cardiac allograft rejection. METHODS: One hundred and forty-six examinations in 73 patients (mean age 53 ± 12 years, 58 men) were performed using a 1.5 Tesla system and compared to EMB. Examinations included a STIR (short tau inversion recovery) sequence for calculation of edema ratio (ER), a T1-weighted spin-echo sequence for assessment of global relative enhancement (gRE), and inversion-recovery sequences to visualize late gadolinium enhancement (LGE). Histological grade ≥1B was considered relevant rejection. RESULTS: One hundred and twenty-seven (127/146 = 87 %) EMBs demonstrated no or mild signs of rejection (grades ≤1A) and 19/146 (13 %) a relevant rejection (grade ≥1B). Sensitivity, specificity, positive predictive, and negative predictive values were as follows: ER: 63 %, 78 %, 30 %, and 93 %; gRE: 63 %, 70 %, 24 %, and 93 %; LGE: 68 %, 36 %, 13 %, and 87 %; with the combination of ER and gRE with at least one out of two positive: 84 %, 57 %, 23 %, and 96 %. ROC analysis revealed an area under the curve of 0.724 for ER and 0.659 for gRE. CONCLUSION: CMR parameters for myocarditis are useful to detect sub-clinical acute cellular rejection after heart transplantation. Comparable results to myocarditis can be achieved with a combination of parameters. KEY POINTS: • Magnetic resonance imaging is useful for the assessment of cardiac allograft rejection. • CMR has a high negative predictive value for exclusion of allograft rejection. • Diagnostic performance is not yet good enough to replace endomyocardial biopsy.


Assuntos
Biópsia/métodos , Rejeição de Enxerto/diagnóstico , Transplante de Coração , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio/patologia , Doença Aguda , Aloenxertos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos
10.
Eur Radiol ; 24(12): 3277-88, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25097126

RESUMO

BACKGROUND: Intramyocardial haemorrhage (IMH) and microvascular obstruction (MVO) represent reperfusion injury after reperfused ST-elevation myocardial infarction (STEMI) with prognostic impact and "hypointense core" (HIC) appearance in T2-weighted images. We aimed to distinguish between IMH and MVO by using T2 (*)-weighted cardiovascular magnetic resonance imaging (CMR) and analysed influencing factors for IMH development. METHODS AND RESULTS: A total of 151 patients with acute STEMI underwent CMR after primary angioplasty. T2-STIR sequences were used to identify HIC, late gadolinium enhancement to visualise MVO and T2 (*)-weighted sequences to detect IMH. IMH(+)/IMH(-) patients were compared considering infarct size, myocardial salvage, thrombolysis in myocardial infarction (TIMI) flow, reperfusion time, ventricular volumes, function and pre-interventional medication. Seventy-six patients (50%) were IMH(+), 82 (54%) demonstrated HIC and 100 (66%) MVO. IMH was detectable without HIC in 16 %, without MVO in 5% and HIC without MVO in 6%. Multivariable analyses revealed that IMH was associated with significant lower left ventricular ejection fraction and myocardial salvage index, larger left ventricular volume and infarct size. Patients with TIMI flow grade ≤1 before angioplasty demonstrated IMH significantly more often. CONCLUSIONS: IMH is associated with impaired left ventricular function and higher infarct size. T2 and HIC imaging showed moderate agreement for IMH detection. T2 (*) imaging might be the preferred CMR imaging method for comprehensive IMH assessment. KEY POINTS: Intramyocardial haemorrhage is a common finding in patients with acute reperfused myocardial-infarction. T 2 (*) imaging should be the preferred CMR method for assessment of intramyocardial haemorrhage. Intramyocardial haemorrhage can be considered as an important influencing factor on patient's outcome.


Assuntos
Circulação Coronária/fisiologia , Ventrículos do Coração/patologia , Hemorragia/diagnóstico , Imagem Cinética por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico , Reperfusão Miocárdica/métodos , Miocárdio/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/cirurgia , Estudos Retrospectivos , Função Ventricular Esquerda
11.
Curr Cardiol Rep ; 16(8): 511, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24952899

RESUMO

Real-time magnetic resonance imaging (MRI) combines the advantages of excellent soft-tissue characterization in a true 3D anatomical and functional model with the possibility of lesion and gap visualization without the need of any radiation. Therefore, real-time MRI presents a particularly attractive imaging technology to guide electrophysiology studies and catheter ablation procedures. This article aims to provide an overview on current routine clinical application of MRI in the setting of interventional electrophysiology. Furthermore, development of real-time MRI guided electrophysiology studies and first experiences with MRI guided catheter ablation procedures are depicted. In this context advantages, challenges and limitations of real-time MRI guided catheter ablation as well as future perspectives are discussed.


Assuntos
Arritmias Cardíacas/cirurgia , Ablação por Cateter/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Animais , Arritmias Cardíacas/diagnóstico , Ablação por Cateter/tendências , Sistemas Computacionais , Humanos , Imagem por Ressonância Magnética Intervencionista/tendências
12.
Rofo ; 196(3): 273-282, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37944940

RESUMO

PURPOSE: To utilize 4 D flow MRI to acquire normal values of "conventional 2 D flow MRI parameters" in healthy volunteers in order to replace multiple single 2 D flow measurements with a single 4 D flow acquisition. MATERIALS AND METHODS: A kt-GRAPPA accelerated 4 D flow sequence was used. Flow volumes were assessed by forward (FFV), backward (BFV), and net flow volumes (NFV) [ml/heartbeat] and flow velocities by axial (VAX) and absolute velocity (VABS) [m/s] in 116 volunteers (58 females, 43 ±â€Š13 years). The aortic regurgitant fraction (RF) was calculated. RESULTS: The sex-neutral mean FFV, BFV, NFV, and RF in the ascending aorta were 93.5 ±â€Š14.8, 3.6 ±â€Š2.8, 89.9 ±â€Š0.6 ml/heartbeat, and 3.9 ±â€Š2.9 %, respectively. Significantly higher values were seen in males regarding FFV, BFV, NFV and RF, but there was no sex dependency regarding VAX and VABS. The mean maximum VAX was lower (1.01 ±â€Š0.31 m/s) than VABS (1.23 ±â€Š0.35 m/s). We were able to determine normal ranges for all intended parameters. CONCLUSION: This study provides quantitative 4 D flow-derived thoracic aortic normal values of 2 D flow parameters in healthy volunteers. FFV, BFV, NFV, and VAX did not differ significantly from single 2 D flow acquisitions and could therefore replace time-consuming multiple single 2 D flow acquisitions. VABS should not be used interchangeably. KEY POINTS: · 4 D flow MRI can be used to replace 2 D flow MRI measurements.. · The parameter absolute velocities can be assessed by 4 D flow MRI.. · There are sex-dependent differences regarding forward, backward, net aortic blood flow and the aortic valve regurgitant fraction..


Assuntos
Aorta , Imageamento por Ressonância Magnética , Masculino , Feminino , Humanos , Valores de Referência , Voluntários Saudáveis , Velocidade do Fluxo Sanguíneo/fisiologia , Aorta/diagnóstico por imagem , Imageamento Tridimensional , Reprodutibilidade dos Testes , Aorta Torácica/diagnóstico por imagem
13.
Radiology ; 268(3): 890-9, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23579050

RESUMO

PURPOSE: To determine the time course of enhancement patterns in the aorta and endoleaks at dynamic computed tomographic (CT) angiography as well as their effect on the endoleak detection rate in patients who have undergone abdominal aortic endovascular aneurysm repair (EVAR). MATERIALS AND METHODS: This retrospective study was approved by the local ethics committee and compliant with the Declaration of Helsinki. All patients gave written informed consent for the scientific analysis of their data. Seventy-one patients (mean age, 72 years ± 8 [standard deviation]) were retrospectively included after EVAR of the abdominal aorta. All patients underwent dynamic CT angiography with 10 unidirectional scan phases, followed by a venous phase. Endoleaks were detected visually in all scan phases; the magnitude of enhancement was assessed by using region-of-interest measurements in the aorta and the detectable endoleaks. Statistical analysis was performed with the χ(2) test, the paired t test, and analysis of variance with repeated measurements. RESULTS: The highest mean aortic enhancement was achieved 12 seconds after the bolus-tracking threshold, and the highest mean endoleak enhancement was achieved 22 seconds after the bolus-tracking threshold. In total, 44 endoleaks were detected. The detection rates differed significantly in between the dynamic CT angiography phases (minimum, seven endoleaks at 2 seconds after the bolus-tracking threshold; maximum, 44 endoleaks at 27 seconds after the bolus-tracking threshold; P = .001). The highest detection rate was achieved when the contrast between aortic and endoleak enhancement reached its maximum. CONCLUSION: Dynamic CT angiography revealed that the peak enhancement of endoleaks is significantly different than that of the aorta and that endoleaks may not be adequately evaluated with conventional biphasic CT protocols. The use of dynamic CT angiography is associated with a significantly increased detection rate of endoleaks compared with the detection rates at the time points of conventional biphasic CT.


Assuntos
Angiografia/métodos , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/cirurgia , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Iopamidol/análogos & derivados , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/administração & dosagem , Feminino , Humanos , Iopamidol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento
14.
Europace ; 15(1): 101-8, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22849974

RESUMO

AIMS: Magnetic resonance imaging (MRI) in the context of electrophysiology (EP) studies facilitates visualization of complex three-dimensional anatomy and the underlying arrhythmogenic substrate, real-time passive visualization of catheters, atrial and ventricular function and complications, as well as lesion visualization during the ablation without radiation. In the following we report on our first experience of a real-time MRI-guided EP study demonstrating current possibilities and drawbacks. METHODS AND RESULTS: Five consecutive patients (one male, four female; mean age 66 ± 11 years) with symptomatic arrhythmias, three patients with highly symptomatic typical atrial flutter, presented to our hospital for isthmus ablation, one patient for an EP study and one for slow pathway ablation in atrioventricular node re-entry tachychardia. The four ablations were performed successfully in a conventional EP laboratory and complete bidirectional isthmus block was confirmed in three patients with atrial flutter. After the procedure in the EP laboratory all five patients were transferred to a 1.5 T whole-body MRI scanner (Intera) for a diagnostic EP procedure. Two MRI compatible steerable diagnostic/ablation catheters (Vision) were inserted via the femoral sheaths and manipulated by an experienced electrophysiologist using a commercially available interactive real-time steady-state free precession sequence (repetition time = 3 ms, echo time = 1 ms, flip angle = 35°, slice thickness = 10 mm, frame rate = 8/s). All catheters could be placed successfully in the right atrium and ventricle, confirmed by intracardiac electrograms, using passive catheter tracking. Furthermore, simple programmed stimulation maneuvers were performed. During and after the procedure, no adverse effects were observed in any patients. CONCLUSION: To our knowledge, this is the first series of patients with real-time MRI-guided placement of multiple catheters with subsequent performance of stimulation maneuvers. Besides the mentioned benefits, this technology still encounters several limitations, which have to be solved before application in a routine clinical setting. Challenges arise from delineation of precise surface electrocardiogram recordings in the MRI setting along with intracardiac electrograms, easier handling and visualization of catheters, facilitation of immediate defibrillation in the MRI setting and implementation of an active catheter tracking system.


Assuntos
Arritmias Cardíacas/diagnóstico , Mapeamento Potencial de Superfície Corporal/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Idoso , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Cardiol Young ; 23(2): 239-47, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22694856

RESUMO

BACKGROUND: Patients with a congenitally corrected transposition of the great arteries show an increasing incidence of cardiac failure with age. In other systemic right ventricles, such as in dextro-transposition after atrial switch, excessive hypertrophy is a potential risk factor for impaired systolic function. In this trial, we sought to compare systemic function and volumes between patients with congenitally corrected transposition and those with dextro-transposition after atrial switch by using cardiac magnetic resonance imaging. METHODS AND RESULTS: A total of 19 patients (nine male) with congenitally corrected transposition and 31 patients (21 male) with dextro-transposition after atrial switch were studied using a 1.5-Tesla scanner. Cine steady-state free-precession sequences in standard orientations were acquired for volumetric and functional imaging. Patient parameters were compared with those of a group of 25 healthy volunteers. Although patients with congenitally corrected transposition were older, they presented with higher right ventricular ejection fractions (p = 0.04) compared with patients with dextro-transposition. Patients with congenitally corrected transposition showed a weak negative correlation between age at examination and systemic ejection fraction (r = −0.18, p = 0.04) but no correlation between right ventricular myocardial mass index and ejection fraction. There was no significant difference in the right ventricular end-diastolic volumes between both patient groups. CONCLUSION: Although patients with congenitally corrected transposition had a longer pressure load of the systemic right ventricle, ventricular function was better compared with that in patients with dextro-transposition after atrial switch. The results suggest that the systemic ventricles might have partly different physiologies. One difference could be the post-operative situation after atrial switch, which results in impaired atrial contribution to ventricular filling.


Assuntos
Ventrículos do Coração/fisiopatologia , Hipertrofia Ventricular Direita/fisiopatologia , Transposição dos Grandes Vasos/fisiopatologia , Disfunção Ventricular Direita/fisiopatologia , Adolescente , Adulto , Estudos de Casos e Controles , Transposição das Grandes Artérias Corrigida Congenitamente , Feminino , Átrios do Coração/cirurgia , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/patologia , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/patologia , Humanos , Hipertrofia Ventricular Direita/etiologia , Hipertrofia Ventricular Direita/patologia , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Transposição dos Grandes Vasos/complicações , Transposição dos Grandes Vasos/patologia , Transposição dos Grandes Vasos/cirurgia , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/patologia , Adulto Jovem
16.
Quant Imaging Med Surg ; 13(12): 7973-7986, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38106267

RESUMO

Background: The rotational direction (RD) of helical blood flow can be classified as either a clockwise (RD+) or counter-clockwise (RD-) flow. We hypothesized that this simple classification might not be sufficient for analysis in vivo and a simultaneous existence of RD+/- may occur. We utilized volumetric velocity-sensitive cardiovascular magnetic resonance imaging (4D flow MRI) to analyze rotational blood flow in the thoracic aorta. Methods: Forty volunteers (22 females; mean age, 41±16 years) and seventeen patients with bicuspid aortic valves (BAVs) (9 females; mean age, 42±14 years) were prospectively included. The RDs and the calculation of the rotating blood volumes (RBVs) in the thoracic aorta were performed using a pathline-projection strategy. Results: We could confirm a mainly clockwise RD in the ascending, descending aorta and in the aortic arch. Furthermore, we found a simultaneous existence of RD+/RD-. The RD+/--volume in the ascending aorta was significantly higher in BAV patients, the mean RD+/RD- percentage was approximately 80%/20% vs. 60%/40% in volunteers (P<0.01). The maximum RBV always occurred during systole. There was significantly more clockwise than counter-clockwise rotational flow in the ascending aorta (P<0.01) and the aortic arch (P<0.01), but no significant differences in the descending aorta (P=0.48). Conclusions: A simultaneous occurrence of RD+/RD- indicates that a simple categorization in either of both is insufficient to describe blood flow in vivo. Rotational flow in the ascending aorta and in the aortic arch differs significantly from flow in the descending aorta. BAV patients show significantly more clockwise rotating volume in the ascending aorta compared to healthy volunteers.

17.
Geburtshilfe Frauenheilkd ; 83(4): 410-436, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37034416

RESUMO

Aim This completely revised interdisciplinary S2k-guideline on the diagnosis, therapy, and follow-up care of female patients with urinary incontinence (AWMF registry number: 015-091) was published in December 2021. This guideline combines and summarizes earlier guidelines such as "Female stress urinary incontinence," "Female urge incontinence" and "Use of Ultrasonography in Urogynecological Diagnostics" for the first time. The guideline was coordinated by the German Society for Gynecology and Obstetrics (Deutsche Gesellschaft für Gynäkologie und Geburtshilfe, DGGG) and the Working Group for Urogynecology and Plastic Pelvic Floor Reconstruction (Arbeitsgemeinschaft für Urogynäkologie und plastische Beckenbodenrekonstruktion e. V., AGUB). Methods This S2k-guideline was developed using a structured consensus process involving representative members from different medical specialties and was commissioned by the Guidelines Commission of the DGGG, OEGGG and SGGG. The guideline is based on the current version of the guideline "Urinary Incontinence in Adults" published by the European Association of Urology (EAU). Country-specific items associated with the respective healthcare systems in Germany, Austria and Switzerland were also incorporated. Recommendations The short version of this guideline consists of recommendations and statements on the surgical treatment of female patients with stress urinary incontinence and urge incontinence. Specific solutions for the diagnostic workup and treatment of uncomplicated and complicated urinary incontinence are discussed. The diagnostics and surgical treatment of iatrogenic urogenital fistula are presented.

18.
Geburtshilfe Frauenheilkd ; 83(4): 377-409, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37034417

RESUMO

Aim This completely revised interdisciplinary S2k-guideline on the diagnosis, therapy, and follow-up care of female patients with urinary incontinence (AWMF registry number: 015-091) was published in December 2021. This guideline combines and summarizes earlier guidelines such as "Female stress urinary incontinence," "Female urge incontinence" and "Use of Ultrasonography in Urogynecological Diagnostics" for the first time. The guideline was coordinated by the German Society for Gynecology and Obstetrics (Deutsche Gesellschaft für Gynäkologie und Geburtshilfe, DGGG) and the Working Group for Urogynecology and Plastic Pelvic Floor Reconstruction (Arbeitsgemeinschaft für Urogynäkologie und plastische Beckenbodenrekonstruktion e. V., AGUB). Methods This S2k-guideline was developed using a structured consensus process involving representative members from different medical specialties and was commissioned by the Guidelines Commission of the DGGG, OEGGG and SGGG. The guideline is based on the current version of the guideline "Urinary Incontinence in Adults" published by the European Association of Urology (EAU). Country-specific items associated with the respective healthcare systems in Germany, Austria and Switzerland were also incorporated. Recommendations The short version of this guideline consists of recommendations and statements on the epidemiology, etiology, classification, symptoms, diagnostics, and treatment of female patients with urinary incontinence. Specific solutions for the diagnostic workup and appropriate conservative and medical therapies for uncomplicated and complication urinary incontinence are discussed.

19.
Eur Radiol ; 22(12): 2699-709, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22772366

RESUMO

OBJECTIVES: To analyse the value of cardiovascular magnetic resonance (CMR)-derived myocardial parameters to differentiate left ventricular non-compaction cardiomyopathy (LVNC) from other cardiomyopathies and controls. METHODS: We retrospectively analysed 12 patients with LVNC, 11 with dilated and 10 with hypertrophic cardiomyopathy and compared them to 24 controls. LVNC patients had to fulfil standard echocardiographic criteria as well as additional clinical and imaging criteria. Cine steady-state free precession and late gadolinium enhancement (LGE) imaging was performed. The total LV myocardial mass index (LV-MMI), compacted (LV-MMI(compacted)), non-compacted (LV-MMI(non-compacted)), percentage LV-MM(non-compacted), ventricular volumes and function were calculated. Data were compared using analysis of variance and Dunnett's test. Additionally, semi-quantitative segmental analyses of the occurrence of increased trabeculation were performed. RESULTS: Total LV-MMI(non-compacted) and percentage LV-MM(non-compacted) were discriminators between patients with LVCN, healthy controls and those with other cardiomyopathies with cut-offs of 15 g/m(2) and 25 %, respectively. Furthermore, trabeculation in basal segments and a ratio of non-compacted/compacted myocardium of ≥3:1 were criteria for LVNC. A combination of these criteria provided sensitivities and specificities of up to 100 %. None of the LVNC patients demonstrated LGE. CONCLUSIONS: Absolute CMR quantification of the LV-MMI(non-compacted) or the percentage LV-MM(non-compacted) and increased trabeculation in basal segments allows one to reliably diagnose LVNC and to differentiate it from other cardiomyopathies. KEY POINTS: Cardiac magnetic resonance imaging can reliably diagnose left ventricular non-compaction cardiomyopathy. Differentiation of LVNC from other cardiomyopathies and normal hearts is possible. The best diagnostic performance can be achieved if combined MRI criteria for the diagnosis are used.


Assuntos
Cardiomiopatias/diagnóstico , Miocárdio Ventricular não Compactado Isolado/diagnóstico , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Análise de Variância , Estudos de Casos e Controles , Distribuição de Qui-Quadrado , Criança , Meios de Contraste , Diagnóstico Diferencial , Ecocardiografia , Feminino , Gadolínio DTPA , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
20.
J Vasc Interv Radiol ; 23(6): 744-50, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22494657

RESUMO

PURPOSE: To assess differences in aortic and endoleak enhancement in patients after endovascular aneurysm repair (EVAR) with dynamic computed tomography (CT) angiography. MATERIALS AND METHODS: Twenty-one consecutive patients (mean age, 74.5 y ± 6; range, 61-88 y) with endoleaks after EVAR of the abdominal aorta were examined on a second-generation dual-source CT unit with 10 unidirectional scan phases (temporal resolution, 5 s; 80 kV; 120 reference-mAs; z-axis field of view, 283 mm), followed by a venous scan phase. Enhancement was assessed in aorta and endoleaks for all phases by density measurements. The diagnostic reliability of endoleak detection was assessed on a five-point confidence scale. RESULTS: In total, 26 endoleaks (type I, n = 1; type II, n = 25) were detected. The highest detection rate was found in phase 5 (22 s after threshold; P < .01 vs other dynamic phases). Mean peak aortic enhancement (560 HU ± 96) was present in an early arterial phase (phase 3, 12 s after threshold), whereas the mean peak endoleak enhancement (398 HU ± 174) for type II endoleaks was present later, in phase 4 (17 s after threshold). Despite perceived high diagnostic confidence in phases 1 and 2 (ie, typical arterial phase of biphasic CT protocol), only 23% and 62% of endoleaks were detected, respectively, whereas peak diagnostic confidence (phases 4 and 5) corresponded well with the maximum endoleak detection rate but decreased significantly in later phases (ie, 6-10). CONCLUSIONS: Preliminary dynamic CT angiography results in post-EVAR follow-up revealed notably different peaks of endoleak and aortic enhancement, which are not covered sufficiently by conventional biphasic CT protocols. Phase 5 demonstrated the highest type II endoleak detection rate, with high diagnostic confidence.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Meios de Contraste , Endoleak/diagnóstico por imagem , Procedimentos Endovasculares/efeitos adversos , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Distribuição de Qui-Quadrado , Endoleak/etiologia , Feminino , Alemanha , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA