Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 112
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 390(21): 1959-1971, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38587261

RESUMO

BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Bioprótese/efeitos adversos , Insuficiência Cardíaca , Estimativa de Kaplan-Meier , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Falha de Prótese , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos
2.
Eur Heart J ; 45(28): 2519-2532, 2024 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-38820201

RESUMO

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.


Assuntos
Endocardite , Falha de Prótese , Infecções Relacionadas à Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/mortalidade , Endocardite/cirurgia , Endocardite/mortalidade , Remoção de Dispositivo , Próteses Valvulares Cardíacas/efeitos adversos , Bioprótese/efeitos adversos , Resultado do Tratamento , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
3.
J Cardiovasc Electrophysiol ; 34(11): 2225-2232, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37702135

RESUMO

INTRODUCTION: The need for pacemaker is a common complication after transcatheter aortic valve replacement (TAVR). We previously described the Emory Risk Score (ERS) to predict the need for new pacemaker implant (PPM) after TAVR. Metrics included in the score are a history of syncope, pre-existing RBBB, QRS duration ≥140 ms, and prosthesis oversizing ≥16%. To prospectively validate the previously described risk score. METHODS: We prospectively evaluated all patients without pre-existing pacemakers, ICD, or pre-existing indications for pacing undergoing TAVR with the Edwards SAPIEN 3 prosthesis at our institution from March 2019 to December 2020 (n = 661). Patients were scored prospectively; however, results were blinded from clinical decision-making. The primary endpoint was PPM at 30 days after TAVR. Performance of the ERS was evaluated using logistic regression, a calibration curve to prior performance, and receiver operating characteristic (ROC) analysis. RESULTS: A total of 48 patients (7.3%) had PPM after TAVR. A higher ERS predicted an increased likelihood of PPM (OR 2.61, 95% CI: 2.05-3.25 per point, p < 0.001). There was good correlation between observed and expected values on the calibration curve (slope = 1.04, calibration at large = 0.001). The area under the ROC curve was 0.81 (95% CI [0.74-0.88], p < 0.001). CONCLUSIONS: The ERS prospectively predicted the need for PPM in a serial, real-world cohort of patients undergoing TAVR with a balloon-expandable prosthesis, confirming findings previously described in retrospective cohorts. Notably, the prospective performance of the score was comparable with that of the initial cohorts. The risk score could serve as a framework for preprocedural risk stratification for PPM after TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
4.
J Card Fail ; 29(7): 1046-1055, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36958391

RESUMO

BACKGROUND: Left ventricular (LV) volume reshaping reduces myocardial wall stress and may induce reverse remodeling in patients with heart failure with reduced ejection fraction. The AccuCinch Transcatheter Left Ventricular Restoration system consists of a series of anchors connected by a cable implanted along the LV base that is cinched to the basal free wall radius. We evaluated the echocardiographic and clinical outcomes following transcatheter left ventricular restoration. METHODS AND RESULTS: We analyzed 51 heart failure patients with a left ventricular ejection fraction between 20% and 40%, with no more than 2+ mitral regurgitation treated with optimal medical therapy, who subsequently underwent transcatheter left ventricular restoration. Serial echocardiograms, Kansas City Cardiomyopathy Questionnaire scores, and 6-minute walk test distances were measured at baseline through 12 months. Primary analysis end point was change in end-diastolic volume at 12 months compared with baseline. Patients (n = 51) were predominantly male (86%) with a mean age of 56.3 ± 13.1 years. Fluoroscopy showed LV free wall radius decreased by a median of 9.2 mm amounting to a 29.6% decrease in the free wall arc length. At 12 months, the LV end-diastolic volume decreased by 33.6 ± 34.8 mL (P < .01), with comparable decreases in the LV end-systolic volume. These decreases were associated with significant improvements in the overall Kansas City Cardiomyopathy Questionnaire score (16.4 ± 18.7 points; P < .01) and 6-minute hall walk test distance (45.9 ± 83.9 m; P < .01). There were no periprocedural deaths; through the 1-year follow-up, 1 patient died (day 280) and 1 patient received a left ventricular assist device (day 13). CONCLUSIONS: In patients with heart failure with reduced ejection fraction without significant mitral regurgitation receiving optimal medical therapy, the AccuCinch System resulted in decreases of LV volume, as well as improved quality of life and exercise endurance. A randomized trial is ongoing (NCT04331769).


Assuntos
Cardiomiopatias , Insuficiência Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Qualidade de Vida , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Remodelação Ventricular
5.
Catheter Cardiovasc Interv ; 102(7): 1291-1300, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37890015

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is as an alternative treatment to surgical AVR, but the long-term outcomes of TAVR remain unclear. AIMS: This study aimed to analyze long-term outcomes following TAVR using meta-analysis. METHODS: A literature search was performed with MEDLINE, EMBASE, Cochrane Library, Web of Science, and Google Scholar through November 2022; studies reporting clinical outcomes of TAVR with follow-up periods of ≥8 years were included. The outcomes of interest were overall survival and/or freedom from structural valve deterioration (SVD). Surgical risk was assessed with the Society of Thoracic Surgeons (STS) predicted risk of mortality (PROM) score. A subgroup analysis was conducted for intermediate-/high-surgical risk patients only. RESULTS: Eleven studies including 5458 patients were identified and analyzed. The mean age was 82.0 ± 6.5 years, and mean STS PROM score ranged from 2.9 to 10.6%. Survival rate at 5 and 10 years was 47.7% ± 1.4% and 12.1 ± 2.0%. Five studies including 1509 patients were analyzed for SVD. Freedom from SVD at 5 and 8 years was 95.5 ± 0.7% and 85.1 ± 3.1%. Similar results for survival and SVD were noted in the subgroup analysis of intermediate-/high-risk patients. CONCLUSIONS: Following TAVR, approximately 88% of patients died within 10 years, whereas 85% were free from SVD at 8 years. These date suggest that baseline patient demographic have the greatest impact on survival, and SVD does not seem to have a prognostic impact in this population. Further investigations on longer-term outcomes of younger and lower-risk patients are warranted.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco
6.
Catheter Cardiovasc Interv ; 99(3): 924-931, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34626449

RESUMO

OBJECTIVES: We assessed the impact of conventional delivery system (DS) insertion technique on "Hat-marker" orientation/commissural alignment in patients who underwent transcatheter aortic valve replacement (TAVR) in the Evolut Low Risk Trial CT substudy versus a modified technique. BACKGROUND: Unlike surgical aortic valve replacement, where alignment of the surgical valve commissures with native commissures can be achieved virtually 100% of the time, commissural alignment during TAVR is not achieved consistently. This may subsequently impact the feasibility of both coronary access and reintervention after TAVR. METHODS: "Hat-marker" orientations during deployment were characterized as outer curve (OC), center front (CF), inner curve, and center back. Severe commissure-to-CA overlap was 0-20°. "Hat-marker" orientations and CA overlap were compared to 240 patients from a single center using the modified 3-o'clock flush port DS technique. RESULTS: In the CT substudy in which conventional DS insertion was performed (flush port at 12 o'clock); 154/249 had both analyzable CT and procedural fluoroscopy to validate "Hat-marker" to C-tab/commissural orientation. On post-TAVR CT, Evolut valve commissural orientation and coronary artery (CA) ostia were identified. Compared to conventional DS technique in the CT substudy, the modified technique had higher rates of "Hat-marker" at OC/CF orientation, improved commissural alignment and reduced severe CA overlap; (left main, 14.2 vs. 27.9%; right coronary artery, 11.7 vs. 27.3% both, 5.0 vs. 13.6%; 1 or both CA, 20.8 vs. 41.6%, all p < 0.01). CONCLUSIONS: The modified technique improved initial "Hat-marker" orientation during Evolut deployment and resulted in better commissural alignment and reduced CA overlap.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
J Interv Cardiol ; 2022: 9737245, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36101865

RESUMO

The use of bioprosthetic prostheses during surgical aortic valve replacements has increased dramatically over the last two decades, accounting for over 85% of surgical implantations. Given limited long-term durability, there has been an increase in aortic valve reoperations and reinterventions. With the advent of new technologies, multiple treatment strategies are available to treat bioprosthetic valve failure, including valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR). However, ViV TAVR has an increased risk of higher gradients and patient prosthesis mismatch (PPM) secondary to placing the new valve within the rigid frame of the prior valve, especially in patients with a small surgical bioprosthesis in situ. Bioprosthetic valve fracture allows for placement of a larger transcatheter valve, as well as a fully expanded transcatheter valve, decreasing postoperative gradients and the risk of PPM.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
8.
Curr Cardiol Rep ; 24(9): 1179-1187, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35767177

RESUMO

PURPOSE OF REVIEW: This review summarizes current data supporting a minimalist TAVR approach and identifies the need for additional study to optimize TAVR care. The authors discuss future directions of the TAVR landscape and how this necessitates evolution of minimalist care pathways. RECENT FINDINGS: Transcatheter aortic valve replacement (TAVR) has become a mainstay in the treatment of aortic stenosis since the initial procedure in 2002. Recently, attention has shifted to TAVR optimization and the minimalist approach with a focus on minimizing procedural sedation, protocolization of perioperative management, and prioritization on early discharge. This approach has been shown to be safe and reduce procedure time, length of stay, and overall cost for hospital systems. The minimalist care pathway avoids general anesthesia, shortens procedure time and length of stay, and reduces cost without changing mortality or readmission rates at 30 days. A variety of protocols have been proposed without a clear consensus on specific components or patient eligibility. There is a continued need for data regarding patient risk stratification, valve selection, and discharge strategy as TAVR becomes increasingly common.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Procedimentos Clínicos , Humanos , Tempo de Internação , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
9.
J Card Surg ; 37(12): 4124-4132, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36168827

RESUMO

Transcatheter aortic valve replacement (TAVR) has transformed the treatment of aortic stenosis and pre-procedure planning relies heavily on advanced imaging. Multidetector computed tomography angiography, the "TAVR CT," facilitates essential planning steps of measuring the aortic root for valve sizing and feasibility and assessment of potential access vessels, making it the guideline gold standard in preprocedural TAVR work up. This Impact of Advanced Imaging Techniques on Cardiac Surgery article will examine the development of TAVR CT, illustrate the current impact and utility, and highlight potential areas of future growth. Clinicians who keep informed of these changes and can become proficient with TAVR CT analyses will offer patients the most optimal results and fuel future therapeutic growth.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Tomografia Computadorizada Multidetectores/métodos , Angiografia , Valor Preditivo dos Testes , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 97(5): 940-947, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33382519

RESUMO

OBJECTIVES: We sought to evaluate the safety, efficacy and feasibility of same-day discharge after uncomplicated, minimalist TAVR. BACKGROUND: At the start of the COVID-19 pandemic, we created a same-day discharge (SDD) pathway after conscious sedation, transfemoral (minimalist) TAVR to help minimize risk of viral transmission and conserve hospital resources. Studies support that next-day discharge (NDD) for carefully selected patients following minimalist TAVR is safe and feasible. There is a paucity of data regarding the safety of SDD after TAVR. METHODS: In-hospital and 30 day outcomes of consecutive patients meeting pre-specified criteria for SDD after minimalist TAVR at our institution between March and July of 2020 were reviewed. Outcomes were compared to a NDD cohort from July 2018 through July 2020 that would have met SDD criteria. Primary endpoints were mortality, delayed pacemaker placement, stroke and cardiovascular readmission at 30 days. RESULTS: Twenty nine patients were discharged via the SDD pathway after TAVR. 128 prior NDD patients were identified who met all criteria for SDD. The STS scores were similar between the two groups (SDD 2.6% ±1.5 vs. NDD 2.3% ± 1.2). There were no deaths at 30 days in either group. There was no significant difference in delayed pacemaker placement (SDD 0% vs. NDD 0.8%, p > .99) or cardiovascular readmission (SDD 0% vs. NDD 5.5%, p = .35) at 30 days. CONCLUSIONS: Same day discharge following uncomplicated, minimalist TAVR in selected patients appears to be safe, achieving similar 30 day outcomes as a cohort of next day discharge patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , COVID-19/epidemiologia , Pandemias , Alta do Paciente/tendências , Medição de Risco/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Comorbidade , Feminino , Seguimentos , Humanos , Tempo de Internação/tendências , Masculino , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
11.
Catheter Cardiovasc Interv ; 97(3): 529-539, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-32845036

RESUMO

BACKGROUND: There is a paucity of data regarding the optimum timing of PCI in relation to TAVR. OBJECTIVE: We compared the major adverse cardiovascular and cerebrovascular events (MACCE) rates among patients who underwent percutaneous coronary intervention (PCI) before transcatheter aortic valve replacement (TAVR) with those who received PCI with/after TAVR. METHODS: In this multicenter study, we pooled all consecutive patients who underwent TAVR at three high volume centers. RESULTS: Among 3,982 patients who underwent TAVR, 327 (8%) patients underwent PCI within 1 year before TAVR, 38 (1%) had PCI the same day as TAVR and 15 (0.5%) had PCI within 2 months after TAVR. Overall, among patients who received both PCI and TAVR (n = 380), history of previous CABG (HR:0.501; p = .001), higher BMI at TAVR (HR:0.970; p = .038), and statin therapy after TAVR (HR:0.660, p = .037) were independently associated with lower MACCE while warfarin therapy after TAVR was associated with a higher risk of MACCE (HR:1.779, p = .017). Patients who received PCI within 1 year before TAVR had similar baseline demographics, STS scores, clinical risk factors when compared to patients receiving PCI with/after TAVR. Both groups were similar in PCI (Syntax Score, ACC/AHA lesion class) and TAVR (valve types, access) related variables. There were no significant differences in terms of MACCE (log rank p = .550), all-cause mortality (log rank p = .433), strokes (log rank p = .153), and repeat PCI (log rank p = .054) in patients who underwent PCI with/after TAVR when compared to patients who received PCI before TAVR. CONCLUSION: Among patients who underwent both PCI and TAVR, history of CABG, higher BMI, and statin therapy had lower, while those discharged on warfarin, had higher adverse event rates. Adverse events rates were similar regardless of timing of PCI.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/terapia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
13.
Basic Res Cardiol ; 110(5): 503, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26150250

RESUMO

It is commonly thought that the optimal method for intracoronary administration of cells is to stop coronary flow during cell infusion, in order to prolong cell/vascular wall contact, enhance adhesion, and promote extravasation of cells into the interstitial space. However, occlusion of a coronary artery with a balloon involves serious risks of vascular damage and/or dissection, particularly in non-stented segments such as those commonly found in patients with heart failure. It remains unknown whether the use of the stop-flow technique results in improved donor cell retention. Acute myocardial infarction was produced in 14 pigs. One to two months later, pigs received 10 million indium-111 oxyquinoline (oxine)-labeled c-kit(pos) human cardiac stem cells (hCSCs) via intracoronary infusion with (n = 7) or without (n = 7) balloon inflation. Pigs received cyclosporine to prevent acute graft rejection. Animals were euthanized 24 h later and hearts harvested for radioactivity measurements. With the stop-flow technique, the retention of hCSCs at 24 h was 5.41 ± 0.80 % of the injected dose (n = 7), compared with 4.87 ± 0.62 % without coronary occlusion (n = 7), (P = 0.60). When cells are delivered intracoronarily in a clinically relevant porcine model of chronic ischemic cardiomyopathy, the use of the stop-flow technique does not result in greater myocardial cell retention at 24 h compared with non-occlusive infusion. These results have practical implications for the design of cell therapy trials. Our observations suggest that the increased risk of complications secondary to coronary manipulation and occlusion is not warranted.


Assuntos
Isquemia Miocárdica/cirurgia , Miócitos Cardíacos/transplante , Transplante de Células-Tronco/métodos , Animais , Separação Celular , Modelos Animais de Doenças , Feminino , Citometria de Fluxo , Humanos , Proteínas Proto-Oncogênicas c-kit , Sus scrofa
14.
Catheter Cardiovasc Interv ; 85(1): 118-29, 2015 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-25204308

RESUMO

BACKGROUND: Data are limited regarding transcatheter aortic valve replacement (TAVR)-related thrombocytopenia (TP). We sought to thoroughly characterize the presence, clinical impact, and severity of TP associated with TAVR. METHODS AND RESULTS: Data were collected from 90 patients who underwent TAVR using the Edwards SAPIEN valve (59 TF, 29 TA, 2 Tao). Platelet counts were evaluated peri-procedurally and for 8 days following TAVR. Platelet levels were compared and patients were divided into a no TP (No-TP) group 1, acquired (new) TP (NTP) group 2, pre-existing (pre-TAVR) TP (PTP) group 3, and further stratified based on the severity of TP: mild (M) TP (100-149 × 10(3) cell/µL) and moderate-severe (MS) TP (<100 × 10(3) cell/µL). Pre-TAVR point prevalence and post-TAVR incidence of TP were 40% and 79%, respectively (P < 0.001); nadir platelet count in all groups occurred day 4 post-TAVR. Baseline predictors for developing MS TP in groups 2-3 included baseline TP, leaner body mass, smaller pre-procedural aortic valve area, higher peak aortic jet velocity, and worsening baseline renal function. Development of "major" TP (nadir platelet count <100 × 103 cell/µL, ≥50% decrease) predicted a higher risk of major vascular complications (OR 2.78 [95% CI, 1.58-3.82]) and major bleeding (OR 3.18 [95% CI, 1.33-5.42]) in group 3. CONCLUSION: TAVR-related TP is predictable and classification by PTP and TP severity prior to TAVR allows for better risk stratification in predicting in-hospital clinical outcomes. Major TP in the presence of worsening TP is predictable and is associated with worse clinical outcomes. © 2014 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Trombocitopenia/etiologia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Distribuição de Qui-Quadrado , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Kentucky , Modelos Logísticos , Masculino , Análise Multivariada , Razão de Chances , Contagem de Plaquetas , Valor Preditivo dos Testes , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Trombocitopenia/sangue , Trombocitopenia/diagnóstico , Fatores de Tempo , Resultado do Tratamento
15.
Eur Heart J ; 35(31): 2069-82, 2014 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-24970334

RESUMO

Aortic valve stenosis is the most common form of valvular heart disease in the elderly population and occurs frequently in conjunction with coronary artery disease. The standard treatment option for patients with these two conditions has been surgical aortic valve replacement and coronary artery bypass grafting. The arrival of transcatheter aortic valve replacement has considerably shifted the treatment paradigms. Nevertheless, a lot of questions remain unanswered regarding the management of coronary artery disease in the setting of the transcatheter options for severe aortic stenosis. This article includes a comprehensive review of the literature and seeks to describe the actual knowledge on the topic of aortic stenosis and concomitant coronary artery disease.


Assuntos
Estenose da Valva Aórtica/complicações , Doença da Artéria Coronariana/complicações , Adulto , Idoso , Algoritmos , Estenose da Valva Aórtica/cirurgia , Terapia Combinada , Doença da Artéria Coronariana/cirurgia , Circulação Coronária/fisiologia , Implante de Prótese de Valva Cardíaca , Humanos , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea , Complicações Pós-Operatórias/etiologia , Tempo para o Tratamento , Substituição da Valva Aórtica Transcateter , Resultado do Tratamento , Calcificação Vascular/complicações
16.
Ann Cardiothorac Surg ; 13(3): 236-243, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38841088

RESUMO

For decades, surgeons have recognized the risk of prosthesis-patient mismatch (PPM) when treating aortic stenosis (AS) with surgical aortic valve replacement (SAVR). The concept of PPM-or placing a valve that is too small for the cardiac output requirements of the patient-has been associated with worse patient outcomes, including increased risk of death. Transcatheter aortic valve replacement (TAVR) has become the standard treatment for most patients with severe symptomatic AS and is associated with improved hemodynamics and lower risks of PPM. Larger surgical valves, stentless, and sutureless technology, and surgical aortic annulus enlargement (AAE) have been employed to avoid severe PPM. However, especially in the small aortic annulus (SAA), TAVR may provide a benefit. Understanding who is at risk for PPM requires preplanning, and cardiac-gated computed tomography (CT) imaging is the standard of care when considering TAVR. It should be standard for all patients with AS. Once SAA is identified, the risk of PPM can be calculated, and an informed decision made on whether to proceed with SAVR or TAVR. In the current TAVR era, younger patients are treated with TAVR driven by patient preference, but with little long-term data to support the practice. Selecting the best valve for the patient is a multifactorial decision often nuanced by anatomical considerations, hemodynamic and durability expectations, and decisions regarding lifetime management that may include placing a second valve. Although PPM may be only one of the factors to consider, the association with elevated mean gradients and worse outcomes certainly makes TAVR a good solution for many patients.

17.
Interv Cardiol ; 19: e10, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39081829

RESUMO

Mitral regurgitation is the most common valvular disease in the developed world, with approximately 24.2 million people being affected worldwide and a higher prevalence in older age groups. Surgical correction of degenerative mitral regurgitation is the standard of care and can restore cardiac function and provide a lasting result, especially when the mitral valve can be repaired. Secondary mitral regurgitation, or functional mitral regurgitation (FMR), describes atrial or ventricular factors leading to poor coaptation of an otherwise non-diseased valve. For FMR, traditional surgery has not produced the same level of benefit. Transcatheter mitral repair and replacement techniques that mimic surgical correction are under investigation. Transcatheter edge-to-edge repair is the only approved catheter-based therapy for FMR in the US. Here, the transcatheter treatment options for FMR are reviewed.

18.
Artigo em Inglês | MEDLINE | ID: mdl-39095289

RESUMO

BACKGROUND: Transfemoral transcatheter aortic valve replacement (TF-TAVR) has proven superior to alternative access. However, some patients evaluated for TF-TAVR are unfit secondary to peripheral arterial disease (PAD). Peripheral intravascular lithotripsy (IVL) can facilitate femoral access. This study aimed to characterize optimal lesions that can be treated with IVL. METHODS: Single-center, retrospective analysis of an institutional database, queried from 1/2018 through 7/2023 for all patients who underwent TAVR. Patients who received IVL-facilitated transfemoral access were analyzed. RESULTS: Of 2862 TAVR cases identified, 92 (3.2 %) underwent lithotripsy. The IVL-facilitated cohort had a mean age of 78 ± 9.2 years and 45 % were female. The right common iliac artery was most treated (47). Most IVL was performed with 7-mm balloons (73.9 %). All cases were successful. 30-day mortality was 1.1 % (1/92). CONCLUSIONS: In our cohort, complications after IVL-facilitated TF-TAVR were more common with small vessel diameter (≤4.7 mm), significant luminal loss (>50 % stenosis), and heavy calcium burden (arc calcification >180°). The findings support the use of IVL to expand the population of patients who can undergo TF-TAVR without the increased risks associated with the various forms of alternative access. SUMMARY FOR ANNOTATED TABLE OF CONTENTS: IVL-facilitated TF-TAVR is safe and feasible. Despite its introduction to TAVR clinical practice in 2018, IVL-facilitated TF-TAVR is not regularly performed and could increase the population of patients eligible for TF-TAVR.

19.
J Am Heart Assoc ; 13(9): e033846, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38639328

RESUMO

BACKGROUND: Next-day discharge (NDD) outcomes following uncomplicated self-expanding transcatheter aortic valve replacement have not been studied. Here, we compare readmission rates and clinical outcomes in NDD versus non-NDD transcatheter aortic valve replacement with Evolut. METHODS AND RESULTS: Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry patients (n=29 597) undergoing elective transcatheter aortic valve replacement with self-expanding supra-annular valves (Evolut R, PRO, and PRO+) from July 2019 to June 2021 were stratified by postprocedure length of stay: ≤1 day (NDD) versus >1 day (non-NDD). Propensity score matching was used to compare risk adjusted 30-day readmission rates and 1-year outcomes in NDD versus non-NDD, and multivariable regression to determine predictors of NDD and readmission. Between the first and last calendar quarter, the rate of NDD increased from 45.4% to 62.1% and median length of stay decreased from 2 days to 1. Propensity score matching produced relatively well-matched NDD and non-NDD cohorts (n=10 549 each). After matching, NDD was associated with lower 30-day readmission rates (6.3% versus 8.4%; P<0.001) and 1-year adverse outcomes (death, 7.0% versus 9.3%; life threatening/major bleeding, 1.6% versus 3.4%; new permanent pacemaker implantation/implantable cardioverter-defibrillator, 3.6 versus 11.0%; [all P<0.001]). Predictors of NDD included non-Hispanic ethnicity, preexisting permanent pacemaker implantation/implantable cardioverter-defibrillator, and previous surgical aortic valve replacement. CONCLUSIONS: Most patients undergoing uncomplicated self-expanding Evolut transcatheter aortic valve replacement are discharged the next day. This study found that NDD can be predicted from baseline patient characteristics and was associated with favorable 30-day and 1-year outcomes, including low rates of permanent pacemaker implantation and readmission.


Assuntos
Estenose da Valva Aórtica , Alta do Paciente , Readmissão do Paciente , Pontuação de Propensão , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/tendências , Readmissão do Paciente/estatística & dados numéricos , Readmissão do Paciente/tendências , Masculino , Feminino , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Idoso , Alta do Paciente/tendências , Sistema de Registros , Tempo de Internação/estatística & dados numéricos , Tempo de Internação/tendências , Fatores de Tempo , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento , Estados Unidos/epidemiologia , Fatores de Risco , Valva Aórtica/cirurgia , Estudos Retrospectivos , Desenho de Prótese , Medição de Risco
20.
J Soc Cardiovasc Angiogr Interv ; 3(1): 101066, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-39131970

RESUMO

Background: Lack of standardization in posttranscatheter aortic valve replacement (TAVR) conduction disturbance (CD) identification and treatment may affect permanent pacemaker implantation (PPI) rates and clinical outcomes. The safety and efficacy of a standardized TAVR CD algorithm has not been analyzed. This study analyzes the Optimize PRO post-TAVR CD management algorithm with Evolut PRO/PRO+ valves. Methods: Optimize PRO is a prospective, postmarket study implementing 2 strategies to reduce pacemaker rates: TAVR with cusp overlap technique and a post-TAVR CD algorithm. The 2-hour postprocedural electrocardiogram (ECG) stratified patients to early discharge in the absence of new ECG changes or to CD algorithms for (1) ECG changes with preexisting right or left bundle branch block (LBBB), interventricular conduction delay or first-degree atrioventricular block, (2) new LBBB, or (3) high-degree atrioventricular block (HAVB). Results: The interim analysis of the CD cohort consisted of 125/400 TAVR recipients. In the CD cohort, the 30-day new PPI rate was higher (28.1% vs 1.5%; P <.001), and 60 (48%) patients were discharged with a 30-day continuous ECG monitor. At 30 days, 90% of patients discharged with a monitor did not require PPI. Clinical outcomes, including mortality, stroke, bleeding, and reintervention, were similar in patients with and without CDs. No patient experienced sudden cardiac death. Conclusions: Effective management of CDs using a standard algorithm following Evolut TAVR provides similar 30-day safety outcomes to patients without CDs who undergo routine next day discharge. The CD algorithm may provide an effective strategy to recognize arrhythmias early, improve PPI utilization, and facilitate safe monitoring of patients after discharge.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA