Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 2023 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-38009385

RESUMO

BACKGROUND: Blood flow signals may be a confounder in quantifying T1 values of plaque or thrombus and how to realize black-blood T1 mapping remains a challenge task. PURPOSE: To develop a fast and three-dimensional black-blood T1 mapping technique for quantitative assessment of atherosclerosis and venous thrombosis. STUDY TYPE: Sequence development and optimization via phantoms and volunteers as well as pilot prospective. PHANTOM AND SUBJECTS: Numerical simulations, a standard phantom, 8 healthy volunteers (mean age, 22 ± 1 years; 5 males), and 19 patients (mean age, 57 ± 14 years; 13 males) with atherosclerosis or venous thrombosis. FIELD STRENGTH/SEQUENCE: 3T/inversion recovery spin-echo sequence (IR-SE), magnetization prepared 2 rapid acquisition gradient echoes (MP2RAGE), and black-blood prepared MP2RAGE (BB-MP2RAGE). ASSESSMENT: The black-blood preparation (i.e., delay alternating with nutation for tailored excitation, DANTE) was incorporated into MP2RAGE for black-blood T1 mapping. The BB-MP2RAGE was optimized numerically based on the Bloch equation, and then the phantom study was performed to verify the accuracy of T1 mapping by BB-MP2RAGE against IR-SE and MP2RAGE. Preliminary clinical validation was prospectively performed to assess the flow suppression effect and its potential application in plaque and thrombosis identification. STATISTICAL TESTS: Pearson correlation test, Bland-Altman analysis, paired t-test, and intraclass correlation coefficient. A P value <0.05 indicates a statistically significant difference. RESULTS: Phantom experiments showed comparable accuracy of T1 maps by BB-MP2RAGE with IR-SE and MP2RAGE (all r2 > 0.99); Compared to MP2RAGE, BB-MP2RAGE effectively nulled the blood flow signals, and had a significant improvement in contrast-to-noise ratio between static tissue and blood (250.5 ± 66.6 vs. 91.9 ± 35.9). BB-MP2RAGE can quantify plaque or thrombus T1 relaxation time with blood flow signal suppression. DATA CONCLUSION: Accurate T1 mapping with sufficient blood flow suppression was achieved by BB-MP2RAGE. BB-MP2RAGE has the potential to quantitatively characterize atherosclerosis and venous thrombosis. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 1.

2.
Magn Reson Imaging ; 96: 17-26, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36375762

RESUMO

PURPOSE: To develop and evaluate a sequence in which water excitation with lipid insensitive binomial off-resonant radio frequency excitation (LIBRE) pulses is incorporated into three-dimensional (3D) variable flip angle fast spin echo (LIBRE-vf-FSE) for fat-free and large field of view imaging at 3 Tesla (T). MATERIALS AND METHODS: Numerical simulation was conducted to optimize the parameters of LIBRE pulses, including the flip angle, pulse duration, and frequency offset, for maximizing the fat suppression effect of the proposed LIBRE-vf-FSE sequence. The sequence was then implemented at 3 T and assessed in phantoms, lower extremity imaging of 8 healthy volunteers, and head/neck imaging of 5 healthy volunteers. Conventional water excitation (WE) and fat saturation (FatSat) were also performed for comparison. Signal-to-noise ratio (SNR) of fat and contrast-to-noise ratio (CNR) between fat and water were used to evaluate the level of fat suppression. Standard deviation (SD) of SNR was used to evaluate the uniformity of fat suppression. RESULTS: The numerical simulation demonstrated that LIBRE-vf-FSE enables large volume imaging with uniform fat suppression, which was further confirmed by phantom and healthy volunteer experiments. LIBRE provided the lowest fat SNR and offered more uniform fat suppression compared with the WE and FatSat. Specifically, average oil SNRs obtained by LIBRE (1.10 ms, 360 Hz, and 60°), WE, and FatSat were (180.1 vs. 280.2 vs. 811.2) in phantom experiments, and average fat SNRs and SDs in legs obtained by LIBRE (1.10 ms, 360 Hz, and 60°), WE, and FatSat were (85.1 vs. 105.0 vs. 105.1) and (22.4 vs. 27.4 vs. 56.4) in vivo experiments, respectively. CONCLUSION: The proposed LIBRE-vf-FSE sequence allows for fat suppression and large field of view imaging at 3 T. It could be an alternative approach for fat-free vf-FSE scan.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Água , Aumento da Imagem/métodos , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA