Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Xray Sci Technol ; 20(3): 351-62, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22948356

RESUMO

A mathematical derivation was conducted to illustrate that exact 3D image reconstruction could be achieved for z-homogeneous phantoms from data acquired with 2D general trajectories using the back projection filtration (BPF) algorithm. The conclusion was verified by computer simulation and experimental result with a circular scanning trajectory. Furthermore, the effect of the non-uniform degree along z-axis of the phantoms on the accuracy of the 3D reconstruction by BPF algorithm was investigated by numerical simulation with a gradual-phantom and a disk-phantom. The preliminary result showed that the performance of BPF algorithm improved with the z-axis homogeneity of the scanned object.


Assuntos
Algoritmos , Tomografia Computadorizada de Feixe Cônico/métodos , Simulação por Computador , Tomografia Computadorizada de Feixe Cônico/instrumentação , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas
2.
IEEE Trans Inf Technol Biomed ; 15(4): 655-60, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21659036

RESUMO

Micro-CT with a high spatial resolution in combination with computer-based-reconstruction techniques is considered a powerful tool for morphological study of insects. The quality of CT images crucially depends on the precise knowledge of the scan geometry of the micro-CT system. In this paper, we have proposed a method to calculate the deviation of rotating axis for compensating deficiency of existing methods. A practical application of this geometric calibration method of the micro-CT system for insect imaging is presented. We have performed the computer-simulation study and experimental study with our prototype micro-CT system. The results demonstrate that the proposed technique is accurate and robust. In addition, we have evaluated the imaging characteristics of the detector in terms of modulation-transfer function (MTF). Finally, insect imaging performance and image reconstruction from data acquired with different energies are presented.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Insetos/anatomia & histologia , Microtomografia por Raio-X/normas , Algoritmos , Animais , Calibragem , Imagens de Fantasmas , Microtomografia por Raio-X/instrumentação , Microtomografia por Raio-X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA