Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38696701

RESUMO

AIMS: Women have been historically underrepresented in implantable cardioverter-defibrillator (ICD) trials. No data on sex differences regarding subcutaneous ICDs (S-ICD) carriers have been described. Aim of our study was to investigate sex-related differences among unselected S-ICD recipients. METHODS AND RESULTS: Consecutive patients enrolled in the multicentre, international i-SUSI registry were analysed. Comparisons between sexes were performed using a 1:1 propensity matching adjusted analysis for age, body mass index (BMI), left ventricular function, and substrate. The primary outcome was the rate of appropriate shocks during follow-up. Inappropriate shocks and other device-related complications were deemed secondary outcomes. A total of 1698 patients were extracted from the i-SUSI registry; 399 (23.5%) were females. After propensity matching, two cohorts of 374 patients presenting similar baseline characteristics were analysed. Despite similar periprocedural characteristics and a matched BMI, women resulted at lower risk of conversion failure as per PRAETORIAN score (73.4% vs. 81.3%, P = 0.049). Over a median follow-up time of 26.5 [12.7-42.5] months, appropriate shocks were more common in the male cohort (rate/year 3.4% vs. 1.7%; log-rank P = 0.049), while no significant differences in device-related complications (rate/year: 6.3% vs. 5.8%; log-rank P = 0.595) and inappropriate shocks (rate/year: 4.3% vs. 3.1%; log-rank P = 0.375) were observed. After controlling for confounders, sex remained significantly associated with the primary outcome (aHR 1.648; CI 0.999-2.655, P = 0.048), while not resulting predictor of inappropriate shocks and device-related complications. CONCLUSION: In a propensity-matched cohort of S-ICD recipients, women are less likely to experience appropriate ICD therapy, while not showing higher risk of device-related complications. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT0473876.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Pontuação de Propensão , Sistema de Registros , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Fatores Sexuais , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Arritmias Cardíacas/terapia , Medição de Risco , Europa (Continente) , Fatores de Tempo , Morte Súbita Cardíaca/prevenção & controle
2.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584394

RESUMO

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cardioversão Elétrica/efeitos adversos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
3.
Artif Organs ; 48(5): 525-535, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38213270

RESUMO

BACKGROUND: Left ventricular assist device (L-VAD) implantation is increasingly used in patients with heart failure (HF) and most patients also have an implantable cardioverter defibrillator (ICD). Limited data are available on the incidence of ICD therapies and complications in this special setting. The aim of this study was to analyze the real-world incidence and predictors of ICD therapies, complications and interactions between ICD and L-VAD. METHODS: We conducted a multicenter retrospective observational study in patients with advanced HF implanted with ICD and a continuous-flow L-VAD, followed-up in five advanced HF centers in Northern Italy. RESULTS: A total of 234 patients (89.7% male, median age 59, 48.3% with ischemic etiology) were enrolled. After a median follow-up of 21 months, 66 patients (28.2%) experienced an appropriate ICD therapy, 22 patients (9.4%) an inappropriate ICD therapy, and 17 patients (7.3%) suffered from an interaction between ICD and L-VAD. The composite outcome of all ICD-related complications was reported in 41 patients (17.5%), and 121 (51.7%) experienced an L-VAD-related complication. At multivariable analysis, an active ventricular tachycardia (VT) zone and a prior ICD generator replacement were independent predictors of ICD therapies and of total ICD-related complications, respectively. CONCLUSIONS: Real-world patients with both L-VAD and ICD experience a high rate of ICD therapies and complications. Our findings suggest the importance of tailoring device programming in order to minimize the incidence of unnecessary ICD therapies, thus sparing the need for ICD generator replacement, a procedure associated to a high risk of complications.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Coração Auxiliar , Taquicardia Ventricular , Feminino , Humanos , Masculino , Arritmias Cardíacas/etiologia , Desfibriladores Implantáveis/efeitos adversos , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/etiologia , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Taquicardia Ventricular/etiologia , Resultado do Tratamento , Pessoa de Meia-Idade
4.
Pacing Clin Electrophysiol ; 45(6): 752-760, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35403246

RESUMO

BACKGROUND: Little is known regarding the characterization of electrical substrate in both atria in patients with atrial fibrillation (AF). METHODS: Eight consecutive patients undergoing AF ablation (five paroxysmal, three persistent) underwent electrical substrate characterization during sinus rhythm. Mapping of the left (LA) and right atrium (RA) was performed with the use of the HD Grid catheter (Abbott). Bipolar voltage maps were analyzed to search for low voltage areas (LVA), the following electrophysiological phenomena were assessed: (1) slow conduction corridors, and (2) lines of block. EGMs were characterized to search for fractionation. Electrical characteristics were compared between atria and between paroxysmal versus persistent AF patients. RESULTS: In the RA, LVAs were present in 60% of patients with paroxysmal AF and 100% of patients with persistent AF. In the LA, LVAs were present in 40% of patients with paroxysmal AF and 66% of patients with persistent AF. The areas of LVA in the RA and LA were 4.8±7.3 cm2 and 7.8±13.6 cm2 in patients with paroxysmal AF versus 11.7±3.0 cm2 and 2.1±1.8 cm2 in patients with persistent AF. In the RA, slow conduction corridors were present in 40.0% (paroxysmal AF) versus 66.7% (persistent AF) whereas in the LA, slow conduction corridors occurred in 20.0% versus 33.3% respectively (p = ns). EGM analysis showed more fractionation in persistent AF patients than paroxysmal (RA: persistent AF 10.8 vs. paroxysmal AF 4.7%, p = .036, LA: 10.3 vs. 4.1%, p = .108). CONCLUSION: Bi-atrial involvement is present in patients with paroxysmal and persistent AF. This is expressed by low voltage areas and slow conduction corridors whose extension progresses as the arrhythmia becomes persistent. This electrophysiological substrate demonstrates the important interplay with the pulmonary vein triggers to constitute the substrate for persistent arrhythmia.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração , Humanos , Veias Pulmonares/cirurgia
5.
Artif Organs ; 46(8): 1608-1615, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35292988

RESUMO

BACKGROUND: Ventricular arrhythmias (VAs) are observed in 25%-50% of continuous-flow left ventricular assist device (CF-LVAD) recipients, but their role on mortality is debated. METHODS: Sixty-nine consecutive patients with a CF-LVAD were retrospectively analyzed. Study endpoints were death and occurrence of first episode of VAs post CF-LVAD implantation. Early VAs were defined as VAs in the first month after CF-LVAD implantation. RESULTS: During a median follow-up of 29.0 months, 19 patients (27.5%) died and 18 patients (26.1%) experienced VAs. Three patients experienced early VAs, and one of them died. Patients with cardiac resynchronization therapy (CRT-D) showed a trend toward more VAs (p = 0.076), compared to patients without CRT-D; no significant difference in mortality was found between patients with and without CRT-D (p = 0.63). Patients with biventricular (BiV) pacing ≥98% experienced more frequently VAs (p = 0.046), with no difference in mortality (p = 0.56), compared to patients experiencing BiV pacing <98%. There was no difference in mortality among patients with or without VAs after CF-LVAD [5 patients (27.8%) vs. 14 patients (27.5%), p = 0.18)], and patients with or without previous history of VAs (p = 0.95). Also, there was no difference in mortality among patients with a different timing of implant of implantable cardioverter-defibrillator (ICD), before and after CF-LVAD (p = 0.11). CONCLUSIONS: VAs in CF-LVAD are a common clinical problem, but they do not impact mortality. Timing of ICD implantation does not have a significant impact on patients' survival. Patients with BiV pacing ≥98% experienced more frequently VAs.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Coração Auxiliar , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Terapia de Ressincronização Cardíaca/efeitos adversos , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Resultado do Tratamento
6.
Medicina (Kaunas) ; 59(1)2022 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-36676690

RESUMO

Background. Data on leadless pacemaker (LPM) implantation in an emergency setting are currently lacking. Objective. We aimed to investigate the feasibility of LPM implantation for emergency bradyarrhythmia, in patients referred for urgent PM implantation, in a large, multicenter, real-world cohort of LPM recipients. Methods. Two cohorts of LPM patients, stratified according to the LPM implantation scenario (patients admitted from the emergency department (ED+) vs. elective patients (ED−)) were retrieved from the iLEAPER registry. The primary outcome of the study was a comparison of the peri-procedural complications between the groups. The rates of peri-procedural characteristics (overall procedural and fluoroscopic duration) were deemed secondary outcomes. Results. A total of 1154 patients were enrolled in this project, with patients implanted due to an urgent bradyarrhythmia (ED+) representing 6.2% of the entire cohort. Slow atrial fibrillation and complete + advanced atrioventricular blocks were more frequent in the ED+ cohort (76.3% for ED+ vs. 49.7% for ED−, p = 0.025; 37.5% vs. 27.3%, p = 0.027, respectively). The overall procedural times were longer in the ED+ cohort (60 (45−80) mins vs. 50 (40−65) mins, p < 0.001), showing higher rates of temporary pacing (94.4% for ED+ vs. 28.9% for ED−, p < 0.001). Emergency LPM implantation was not correlated with an increase in the rate of major complications compared to the control group (6.9% ED+ vs. 4.2% ED−, p = 0.244). Conclusion. LPM implantation is a feasible procedure for the treatment of severe bradyarrhythmia in an urgent setting. Urgent LPM implantation was not correlated with an increase in the rate of major complications compared to the control group, but it was associated with longer procedural times.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Humanos , Bradicardia/terapia , Fibrilação Atrial/terapia , Resultado do Tratamento
7.
J Cardiovasc Electrophysiol ; 32(5): 1337-1345, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33682256

RESUMO

BACKGROUND: Ventricular arrhythmias (VAs) are rare in pediatric patients, especially in absence of structural heart disease (SHD). Few data are available regarding the invasive VAs treatment with catheter ablation (CA) in pediatric patients and predictors of outcomes have not been fully investigated. OBJECTIVE: To describe the clinical presentation, procedural characteristics, and outcomes in pediatric patients undergoing CA for VAs. METHODS: Eighty-one consecutive pediatric patients (58 male [72%], 15.5 ± 2.2 years) treated by CA for ventricular tachycardia (VT) or premature ventricular beats (PVBs) were retrospectively evaluated. Study endpoints were VAs recurrence and mortality for any cause. RESULTS: Ninety-five procedures were performed in 81 patients, 52 (55%) PVBs and 43 (45%) VT ablations. During a follow-up of 35.0 months (interquartile range = 13.0-71.0), 14 patients (14.7%) had a VA recurrence: 11 (33.3%) patients treated with CA for VT and 3 (6.2%) patients treated for PVBs (p < .001). One patient (1%) died 26 months after the procedure during an electrical storm. Patients with SHD had higher VAs recurrence rate, as compared with idiopathic VAs (pairwise log-rank p < .001). Patients treated with CA for VT had higher VA recurrence rate, as compared with PVB patients (pairwise log-rank p = .002). At Cox multivariate analysis only SHD was an independent predictor of VAs recurrence (hazard ratio = 5.56, 95% confidence interval = 2.68-11.54, p < .001). CONCLUSION: CA of VAs is effective and safe in a pediatric population. CA of idiopathic and fascicular VAs are associated with lower recurrence rate, than VAs in the setting of SHD.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Ablação por Cateter/efeitos adversos , Criança , Humanos , Masculino , Recidiva , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
8.
J Cardiovasc Electrophysiol ; 32(12): 3179-3186, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34664762

RESUMO

BACKGROUND: Myxomatous mitral valve prolapse (MVP) and mitral-annular disjunction (Barlow disease) are at-risk for ventricular arrhythmias (VA). Fibrosis involving the papillary muscles and/or the infero-basal left ventricular (LV) wall was reported at autopsy in sudden cardiac death (SCD) patients with MVP. OBJECTIVES: We investigated the electrophysiological substrate subtending VA in MVP patients with Barlow disease phenotype. METHODS: Twenty-three patients with VA were enrolled, including five with syncope and four with a history of SCD. Unipolar (Uni < 8.3 mV) and bipolar (Bi < 1.5 mV) low-voltage areas were analyzed with electro-anatomical mapping (EAM), and VA inducibility was evaluated with programmed ventricular stimulation (PES). Electrophysiological parameters were correlated with VA patterns, electrocardiogram (ECG) inferior negative T wave (nTW), and late gadolinium enhancement (LGE) assessed by cardiac magnetic resonance. RESULTS: Premature ventricular complex (PVC) burden was 12 061.9 ± 12 994.6/24 h with a papillary-muscle type (PM-PVC) in 18 patients (68%). Twelve-lead ECG showed nTW in 12 patients (43.5%). A large Uni less than 8.3 mV area (62.4 ± 45.5 cm2 ) was detected in the basal infero-lateral LV region in 12 (73%) patients, and in the papillary muscles (2.2 ± 2.9 cm2 ) in 5 (30%) of 15 patients undergoing EAM. A concomitant Bi less than 1.5 mV area (5.0 ± 1.0 cm2 ) was identified in two patients. A history of SCD, and the presence of nTW, and LGE were associated with a greater Uni less than 8.3 mV extension: (32.8 ± 3.1 cm2 vs. 9.2 ± 8.7 cm2 ), nTW (20.1 ± 11.0 vs. 4.1 ± 3.8 cm2 ), and LGE (19.2 ± 11.7 cm2 vs. 1.0 ± 2.0 cm2 , p = .013), respectively. All patients with PM-PVC had a Uni less than 8.3 mV area. Sustained VA (ventricular tachycardia 2 and VF 2) were induced by PES only in four patients (one with resuscitated SCD). CONCLUSIONS: Low unipolar low voltage areas can be identified with EAM in the basal inferolateral LV region and in the papillary muscles as a potential electrophysiological substrate for VA and SCD in patients with MVP and Barlow disease phenotype.


Assuntos
Prolapso da Valva Mitral , Complexos Ventriculares Prematuros , Meios de Contraste , Gadolínio , Humanos , Prolapso da Valva Mitral/complicações , Músculos Papilares
9.
Rev Cardiovasc Med ; 22(4): 1383-1392, 2021 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-34957778

RESUMO

Ventricular arrhythmias still represent an important cause of morbidity and mortality, especially in patients with heart failure and reduced left ventricular ejection fraction. Amiodarone is a Class III Vaughan-Williams anti-arrhythmic drug widely used in ventricular arrhythmias for its efficacy and low pro-arrhythmogenic effect. On the other hand, a significant limitation in its use is represented by toxicity. In this review, the pharmacology of the drug is discussed to provide the mechanistic basis for its clinical use. Moreover, all the latest evidence on its role in different clinical settings is provided, including the prevention of sudden cardiac death, implanted cardioverter defibrillators, ischemic and non-ischemic cardiomyopathies. A special focus is placed on everyday clinical practice learning points, such as dosage, indications, and contraindications from the latest guidelines.


Assuntos
Amiodarona , Desfibriladores Implantáveis , Amiodarona/efeitos adversos , Antiarrítmicos/efeitos adversos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/tratamento farmacológico , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Humanos , Volume Sistólico , Função Ventricular Esquerda
10.
Europace ; 23(3): 431-440, 2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-33227133

RESUMO

AIMS: Contemporary data from prospective multicentre registries on catheter ablation in pediatric patients are sparse. Aim of the European Pediatric Catheter Ablation Registry EUROPA was to contribute data to fill this gap of knowledge. METHODS AND RESULTS: From July 2012 to June 2017, data on catheter ablation in pediatric patients (≤18 years of age) including a 1-year follow-up from five European pediatric EP centres were collected prospectively. A total of 683 patients (mean age 12.4 ± 3.9 years, mean body weight 50.2 ± 19 kg) were enrolled. Target tachycardia was WPW/atrioventricular-nodal re-entrant tachycardia (AVRT) in 380 (55.7%) patients, AVNRT in 230 (33.8%) patients, ventricular tachycardia (VT) in 24 (3.5) patients, focal atrial tachycardia (FAT) in 20 (2.9%) patients, IART in 14 (2%) patients, and junctional ectopic tachycardia in 3 (0.45) patients. Overall procedural success was 95.6%. Compared with all other substrates, success was significantly lower in FAT patients (80%, n = 16, P = 0.001). Mean procedure duration was 136 ± 67 min and mean fluoroscopy time was 4.9 ± 6.8 min. Major complications occurred in 0.7% of the patients. No persisting AV block requiring permanent pacing was reported. At 1-year follow-up (605/683 patients, 95%), tachycardia recurrence was reported in 7.8% of patients. Recurrence after VT ablation (33%) was significantly higher (P = 0.001) than after ablation of all other substrates. CONCLUSION: The present study proves overall high efficacy and safety of catheter ablation of various tachycardia substrates in pediatric patients. Of note, complication rate was exceptionally low. Long-term success was high except for patients after VT ablation.


Assuntos
Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Ventricular , Adolescente , Ablação por Cateter/efeitos adversos , Criança , Humanos , Estudos Prospectivos , Sistema de Registros , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Resultado do Tratamento
11.
Pacing Clin Electrophysiol ; 44(3): 552-556, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33372694

RESUMO

We present, to our knowledge, the first case of immunosuppressive therapy (IST) application in a 12-year-old child with arrhythmogenic inflammatory cardiomyopathy resulting from the overlap between autoimmune myocarditis and primary arrhythmogenic cardiomyopathy. Indication to off-lable IST was compelling, because of recurrent drug-refractory ventricular arrhythmias (VAs). We show that IST was feasible, safe, and effective on multiple clinical endpoints, including symptoms, VA recurrences, and T-troponin release. Remarkably, all diagnostic and therapeutic strategies were worked out by a dedicated multidisciplinary team, including specialized pediatric immunologists.


Assuntos
Displasia Arritmogênica Ventricular Direita/tratamento farmacológico , Displasia Arritmogênica Ventricular Direita/imunologia , Terapia de Imunossupressão , Azatioprina/uso terapêutico , Biomarcadores/sangue , Criança , Ecocardiografia , Eletrocardiografia , Humanos , Imageamento por Ressonância Magnética , Masculino , Miocardite/tratamento farmacológico , Miocardite/imunologia , Prednisona/uso terapêutico , Recidiva , Fatores de Risco
12.
Pacing Clin Electrophysiol ; 43(8): 891-893, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32543745

RESUMO

BACKGROUND: No studies investigated the prevalence of arrhythmias among clinically-stable patients affected by COVID-19 infection. METHODS: We assessed prevalence, type, and burden of arrhythmias, by a single-day snapshot in seven non-intensive COVID Units at a third-level center. RESULTS: We enrolled 132 inhospital patients (mean age 65±14y; 66% males) newly diagnosed with COVID-19 infection. Arrhythmic episodes were detected in 12 patients (9%). In detail, 8 had atrial fibrillation, and 4 self-limiting supraventricular tachyarrhythmias. There were no cases of ventricular arrhythmias or new-onset atrioventricular blocks. In addition, we report no patients with QTc interval >450 ms. CONCLUSIONS: Our single-day snapshot survey suggests that the prevalence of arrhythmias among clinically stable COVID-19 patients is low. In particular, no life-threatening arrhythmic events occurred.


Assuntos
Arritmias Cardíacas/epidemiologia , COVID-19/complicações , Idoso , COVID-19/epidemiologia , Feminino , Humanos , Itália/epidemiologia , Masculino , Pandemias , Prevalência , SARS-CoV-2
13.
Pediatr Cardiol ; 40(4): 713-718, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30666358

RESUMO

The current approach for catheter ablation (CA) of accessory pathways (AP) includes the use of standard catheters under fluoroscopic visualization. We hypothesize that use of contact force (CF) irrigated tip catheters might increase procedural safety in pediatric patients compared to standard irrigated tip catheters, by decreasing the number of radiofrequency (RF) pulses required to obtain AP elimination. Seventy-one pediatric patients (13.7 ± 2.5 years, 45 male) with ventricular pre-excitation were enrolled in the study. CA was performed with a standard irrigated tip catheter up to June 2013 in 41 patients (Group S) and with a CF sensing irrigated tip catheter later on in 30 patients (Group CF). In the Group CF, RF was applied with a minimal CF of 5 g; CF > 35 g was avoided. Group CF procedures required less fluoroscopy (6.8 ± 4.8 min), compared to Group S (12.2 ± 10.8 min, p = 0.007). The number of RF pulses was smaller in Group CF compared to Group S (2.5 ± 2.0 vs 5.5 ± 1.9, p < 0.01). The mean CF during the effective RF pulse was 18 ± 7.7 g, force-time integral was 1040.7 ± 955.9 gs, Ablation Index was 513.0 ± 214.2. The procedure was acutely successful in 70 patients; at 12 months follow-up 2 patients had AP recurrence, one for each group. No major complications were reported. The use of CF irrigated tip catheters was associated with a smaller number of RF pulses and less fluoroscopy, as compared to mapping and ablation with standard irrigated tip catheters.


Assuntos
Feixe Acessório Atrioventricular/diagnóstico por imagem , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Fluoroscopia/métodos , Adolescente , Estudos de Casos e Controles , Criança , Feminino , Humanos , Masculino , Síndromes de Pré-Excitação/cirurgia , Estudos Prospectivos , Resultado do Tratamento
14.
J Cardiovasc Electrophysiol ; 29(8): 1119-1124, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29543365

RESUMO

INTRODUCTION: Late potentials (LP) abolition is recognized as an effective strategy for substrate ablation of ventricular tachycardia (VT). The presence of a chronic total occlusion in a coronary artery responsible for a previous myocardial infarction (infarct related artery CTO, IRA-CTO) is emerging as a predictor of ventricular arrhythmias and VT recurrence after ablation. We sought to analyze the effects of LP abolition, focusing on the high-risk subgroup of patients with IRA-CTO. METHODS AND RESULTS: This was a single-center, observational study that screened all patients with prior myocardial infarction and clinical VT, referred for VT ablation at San Raffaele Hospital between 2010 and June 2013. Patients were then included in the study if they had a coronary diagnostic angiography (without revascularization) performed during the index hospitalization. The main endpoint was VT recurrence after ablation. Eighty-four patients formed the population of the study. An IRA-CTO was present in 47 patients (56%) and the presence of an IRA-CTO was a predictor of VT recurrence (HR 3.7, P = 0.005). LP were observed in 51 patients and successfully abolished in 38 cases. LP abolition was associated with lower VT recurrence especially among patients with IRA-CTO (24% vs. 65%, P = 0.005). The presence of an IRA-CTO, in combination with no LP abolition, was the strongest predictor of VT recurrence (HR 4.4, P < 0.001). CONCLUSIONS: Late potentials abolition is an effective strategy for substrate ablation of ventricular tachycardia. The additional reduction of VT recurrence achieved with LP abolition on top of noninducibility is especially significant among high-risk patients with IRA-CTO.


Assuntos
Ablação por Cateter/tendências , Oclusão Coronária/cirurgia , Eletrocardiografia/tendências , Infarto do Miocárdio/cirurgia , Taquicardia Ventricular/cirurgia , Idoso , Oclusão Coronária/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Estudos Prospectivos , Fatores de Risco , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento
16.
J Clin Anesth ; 93: 111361, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38118231

RESUMO

Every year, 80,000-100,000 ablation procedures take place in the United States and approximately 1% of these involve paediatric patients. As the paediatric population undergoing catheter ablation to treat dysrhythmia is constantly growing, involvement of anaesthesiologists in the cardiac electrophysiology laboratory is simultaneously increasing. Compared with the adult population, paediatric patients need deeper sedation or general anaesthesia (GA) to guarantee motionlessness and preserve comfort. As a result, the anaesthesiologist working in this setting should keep in mind heart physiopathology as well as possible interactions between anaesthetic drugs and arrhythmia. In fact, drug-induced suppression of accessory pathways (APs) conduction capacity is a major concern for completing a successful electrophysiology study (EPS). Nevertheless, the literature on this topic is scarce and the optimal type of anaesthesia in EPS and ablation procedures in children is still controversial. Thus, the main goal of the present review is to collect the literature published so far on the effects on cardiac conduction tissue of the drugs commonly employed for sedation/GA in the cath lab for EPS and ablation procedures to treat supraventricular tachycardia in patients aged <18 years.


Assuntos
Anestésicos , Ablação por Cateter , Taquicardia Supraventricular , Adulto , Humanos , Criança , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Supraventricular/cirurgia , Frequência Cardíaca , Eletrofisiologia , Ablação por Cateter/efeitos adversos
17.
Int J Cardiol ; 400: 131807, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38272130

RESUMO

BACKGROUND: Left ventricular assist devices (LVADs) are an increasingly used strategy for the management of patients with advanced heart failure (HF). Subcutaneous implantable cardioverter defibrillator (S-ICD) might be a viable alternative to conventional ICDs with a lower risk of short- and long-term of device-related complications and infections.The aim of this multicenter study was to evaluate the outcomes and management of S-ICD recipients who underwent LVAD implantation. METHODS: The study population included patients with a preexisting S-ICD who underwent LVAD implantation for advanced HF despite optimal medical therapy. RESULTS: The study population included 30 patients (25 male; median age 45 [38-52] years).The HeartMate III was the most common LVAD type. Median follow-up in the setting of concomitant use of S-ICDs and LVADs was 7 months (1-20).There were no reports of inability to interrogate S-ICD systems in this population. Electromagnetic interference (EMI) occurred in 21 (70%) patients. The primary sensing vector was the one most significantly involved in determining EMI. Twenty-seven patients (90%) remained eligible for S-ICD implantation with at least one optimal sensing vector. The remaining 3 patients (10%) were ineligible for S-ICD after attempts of reprogramming of sensing vectors. Six patients (20%) experienced inappropriate shocks (IS) due to EMI. Six patients (20%) experienced appropriate shocks. No S-ICD extraction because of need for antitachycardia pacing, ineffective therapy or infection was reported. CONCLUSIONS: Concomitant use of LVAD and S-ICD is feasible in most patients. However, the potential risk of EMI oversensing, IS and undersensing in the post-operative period following LVAD implantation should be considered. Careful screening for EMI should be performed in all sensing vectors after LVAD implantation.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Coração Auxiliar , Marca-Passo Artificial , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações , Coração Auxiliar/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Resultado do Tratamento
18.
Heart Rhythm ; 21(4): 410-418, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38246594

RESUMO

BACKGROUND: Outcome comparisons among subcutaneous implantable cardioverter-defibrillator (S-ICD) recipients with nonischemic cardiomyopathies are scarce. OBJECTIVE: The aim of this study was to evaluate differences in device-related outcomes among S-ICD recipients with different structural substrates. METHODS: Patients enrolled in the i-SUSI (International SUbcutaneouS Implantable cardioverter defibrillator registry) project were grouped according to the underlying substrate (ischemic vs nonischemic) and subgrouped into dilated cardiomyopathy, hypertrophic cardiomyopathy, Brugada syndrome (BrS), arrhythmogenic right ventricular cardiomyopathy (ARVC). The main outcome of our study was to compare the rates of appropriate and inappropriate shocks and device-related complications. RESULTS: Among 1698 patients, the most common underlying substrate was ischemic (31.7%), followed by dilated cardiomyopathy (20.5%), BrS (10.8%), hypertrophic cardiomyopathy (8.5%), and ARVC (4.4%). S-ICD for primary prevention was more common in the nonischemic cohort (70.9% vs 65.4%; P = .037). Over a median (interquartile range) follow-up of 26.5 (12.6-42.8) months, no differences were observed in appropriate shocks between ischemic and nonischemic patients (4.8%/y vs 3.9%/y; log-rank, P = .282). ARVC (9.0%/y; hazard ratio [HR] 2.492; P = .001) and BrS (1.8%/y; HR 0.396; P = .008) constituted the groups with the highest and lowest rates of appropriate shocks, respectively. Device-related complications did not differ between groups (ischemic: 6.4%/y vs nonischemic: 6.1%/y; log-rank, P = .666), nor among underlying substrates (log-rank, P = .089). Nonischemic patients experienced higher rates of inappropriate shocks than did ischemic S-ICD recipients (4.4%/y vs 3.0%/y; log-rank, P = .043), with patients with ARVC (9.9%/y; P = .001) having the highest risk, even after controlling for confounders (adjusted HR 2.243; confidence interval 1.338-4.267; P = .002). CONCLUSION: Most S-ICD recipients were primary prevention nonischemic cardiomyopathy patients. Among those, patients with ARVC tend to receive the most frequent appropriate and inappropriate shocks and patients with BrS the least frequent appropriate shocks.


Assuntos
Displasia Arritmogênica Ventricular Direita , Cardiomiopatias , Cardiomiopatia Dilatada , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Cardioversão Elétrica/efeitos adversos , Displasia Arritmogênica Ventricular Direita/complicações , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/terapia , Sistema de Registros , Resultado do Tratamento
19.
Europace ; 15(12): 1771-6, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23645529

RESUMO

AIM: The evolution mechanical dilator sheath has been reported to be an effective tool for chronic lead extraction (LE). We examined safety and efficacy of evolution system as compared with laser system. METHODS AND RESULTS: From 2005 to 2009, all extractions requiring the use of a powered sheath were performed using the excimer laser system (n = 73). Since 2009, laser system was no longer available and the evolution system was introduced as the first-line method for powered extraction (n = 48). All procedures were performed by a single first operator. Success and complications were defined according to the current guidelines. Patients of the evolution group compared with those of the laser group had a greater number of extracted leads per patient (2.77 vs. 2.4, P = 0.049) and a longer implant duration (101.1 vs. 62.4 months, P = 0.001). Additional use of snare was required in 27.1% of the evolution group and 8.2% of the laser group (P = 0.005). Complete procedural success was achieved in 91.7% of the evolution group and 97.3% of the laser group (P = 0.16). There was also no difference between evolution and laser groups in clinical success (97.9 vs. 98.6%, P = 0.76), as well as regarding major (4.2 vs. 2.7%, P = 0.66) or minor complications (4.2 vs. 5.5%, P = 0.76). CONCLUSION: Use of the recently introduced evolution system for LE exhibit acceptably high levels of safety, as well as of procedural and clinical success, although additional use of snare was required more frequently in the evolution compared with the laser group.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo/métodos , Dilatação , Terapia a Laser , Marca-Passo Artificial , Idoso , Cateteres Cardíacos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/instrumentação , Dilatação/efeitos adversos , Dilatação/instrumentação , Desenho de Equipamento , Feminino , Humanos , Terapia a Laser/efeitos adversos , Terapia a Laser/instrumentação , Lasers de Excimer , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
20.
Pacing Clin Electrophysiol ; 36(4): 486-90, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23356212

RESUMO

BACKGROUND: Irrigated-tip catheter technology has been used for the elimination of resistant accessory pathways (AP) in adults with Wolff-Parkinson-White (WPW) syndrome. However, there are persistent concerns regarding the safety of irrigated catheters in the pediatric population. In this report we present our experience, in terms of effectiveness and safety, of irrigated catheter technology in children and adolescents who underwent ablation of WPW. METHODS: We prospectively followed up all patients less than 18 years old (n = 41, mean age of 12.8 years old) who were referred to our center for radiofrequency (RF) catheter ablation of WPW between January 2010 and July 2011. Catheter ablation was performed in all patients using an open irrigated-tip catheter (Celsius Thermocool 3.5 mm, 7F, B-type, Biosense Webster, Diamond Bar, CA, USA). Power was started from 15 W up to 30 W in right-sided AP; RF pulses in left-sided APs were delivered at 40 W while 20 W was delivered inside the coronary sinus. RESULTS: Mean procedure time was 26.4 minutes and mean fluoroscopy time was 12.2 minutes. Overall procedural success was obtained in 39/41 (95.1%) patients after the first procedure. No complications were observed after the procedure. All patients attended their scheduled follow-up visit at 3, 6, and 12 months and no recurrences were observed based on 12-lead electrocardiogram and 24-hour Holter monitoring. CONCLUSIONS: RF ablation of APs using open irrigated-tip catheters can be performed in children and adolescents with a high acute and long-term success rate, very short procedure times, and acceptable fluoroscopy times.


Assuntos
Ablação por Cateter/instrumentação , Síndrome de Wolff-Parkinson-White/cirurgia , Adolescente , Criança , Eletrocardiografia , Eletrocardiografia Ambulatorial , Feminino , Fluoroscopia , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Irrigação Terapêutica , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA