Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Opt Express ; 31(23): 38840-38853, 2023 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-38017978

RESUMO

Novel focusing optics composed of twin paraboloidal capillaries coated with Pt, for laboratory X-ray sources are presented and characterized. The optics are designed to focus the X-rays, resulting in an achromatic focused beam with photon energies up to 40 keV. The performance of the optics under different operational conditions is studied by comparing the energy-photon count spectra of the direct and focused beams. Based on these analyses, the optics gain and efficiency as a function of photon energy are determined. A focal spot of 8.5 µm with a divergence angle of 0.59° is observed. The obtained characteristics are discussed and related to theoretical considerations. Moreover, the suitability and advantages of the present optics for X-ray microdiffraction is demonstrated using polycrystalline aluminium. Finally, possibilities for further developments are suggested.

2.
J Exp Bot ; 74(21): 6677-6691, 2023 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-37668473

RESUMO

The vasculature along conifer needles is fundamentally different from that in angiosperm leaves as it contains a unique transfusion tissue inside the bundle sheath. In this study, we used specific tracers to identify the pathway of photoassimilates from mesophyll to phloem, and the opposing pathway of nutrients from xylem to mesophyll. For symplasmic transport we applied esculin to the tip of attached pine needles and followed its movement down the phloem. For apoplasmic transport we let detached needles take up a membrane-impermeable contrast agent and used micro-X-ray computed tomography to map critical water exchange interfaces and domain borders. Microscopy and segmentation of the X-ray data enabled us to render and quantify the functional 3D structure of the water-filled apoplasm and the complementary symplasmic domain. The transfusion tracheid system formed a sponge-like apoplasmic domain that was blocked at the bundle sheath. Transfusion parenchyma cell chains bridged this domain as tortuous symplasmic pathways with strong local anisotropy which, as evidenced by the accumulation of esculin, pointed to the phloem flanks as the preferred phloem-loading path. Simple estimates supported a pivotal role of the bundle sheath, showing that a bidirectional movement of nutrient ions and assimilates is feasible and emphasizing the role of the bundle sheath in nutrient and assimilate exchange.


Assuntos
Traqueófitas , Traqueófitas/metabolismo , Esculina/metabolismo , Transporte Biológico , Folhas de Planta/metabolismo , Nutrientes , Água/metabolismo , Floema/metabolismo
3.
Phys Rev Lett ; 131(18): 181401, 2023 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-37977635

RESUMO

Fine-tuning generic but smooth spherically symmetric initial data for general relativity to the threshold of dynamical black hole formation creates arbitrarily large curvatures, mediated by a universal self-similar solution that acts as an intermediate attractor. For vacuum gravitational waves, however, these critical phenomena have been elusive. We present, for the first time, excellent agreement among three independent numerical simulations of this collapse. Surprisingly, we find no universality, and observe approximate self-similarity for some families of initial data but not for others.

4.
Acta Orthop ; 92(5): 621-627, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34102950

RESUMO

Background and purpose - We noted several adverse events in patients in whom the first version of the STRYDE limb-lengthening nail (NuVasive Specialized Orthopaedics, San Diego, CA) had been implanted. Pain, osteolysis, periosteal reactions, and cortical hypertrophy at the nail junction were noted. Here, we present the analysis of 23 retrieved STRYDE implants.Materials and methods - We undertook visual inspection of the retrieved nails and screws, mechanical evaluation of the junction, micro-CT analyses, microscopic inspection of the bushing, screws, screw holes, and separated parts of the implants. Positive material identification (PMI) and energy-dispersive X-ray spectroscopy (EDS) were used to analyze the chemical composition. The hardness of the material was also investigated.Results - 20/23 retrieved nails had visible signs of corrosion, i.e., discoloration at the telescopic junction. Micro-CT verified corrosion attacks in 12/12 scanned bushings. Corrosion, predominantly mechanically assisted crevice corrosion, was observed at the locking screws and screw holes in 20/23 nails. Biological material inside the nail was observed in addition to oozing from the junction of 2 nails during hardware removal, which was experimentally reproducible. Notably, the mechanical construction of the bushing changed from PRECICE P2 to STRYDE nails.Interpretation - STRYDE nails are not hermetically sealed, and liquid can pass the bushing. Biodur 108 itself is corrosion resistant; however, mechanically assisted crevice corrosion of the bushing, locking screws, and screw holes may be aggravated due to manufacturing aiming for increased strength and hardness of the alloy.Observing several adverse events, we recently published a nationwide cross-sectional analysis of all 30 STRYDE limb- lengthening nails (NuVasive, Specialized Orthopedics, San Diego, CA) that were implanted in Denmark (Rölfing et al. 2021a). 27/30 STRYDE nails have now been removed and we present data from metallurgical analysis of 23 of the retrieved implants.


Assuntos
Alongamento Ósseo/instrumentação , Pinos Ortopédicos/efeitos adversos , Parafusos Ósseos/efeitos adversos , Adolescente , Adulto , Idoso , Criança , Corrosão , Estudos Transversais , Dinamarca , Remoção de Dispositivo , Fêmur/cirurgia , Humanos , Pessoa de Meia-Idade , Tíbia/cirurgia , Adulto Jovem
5.
Phys Rev Lett ; 123(17): 171103, 2019 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-31702276

RESUMO

We numerically investigate the threshold of black-hole formation in the gravitational collapse of electromagnetic waves in axisymmetry. We find approximate power-law scaling ρ_{max}∼(η_{*}-η)^{-2γ} of the maximum density in the time evolution of near-subcritical data with γ≃0.145, where η is the amplitude of the initial data. We directly observe approximate discrete self-similarity in near-critical time evolutions with a log-scale echoing period of Δ≃0.55. The critical solution is approximately the same for two families of initial data, providing some evidence of universality. Neither the discrete self-similarity nor the universality, however, are exact. We speculate that the absence of an exactly discrete self-similarity might be caused by the interplay of electromagnetic and gravitational wave degrees of freedom, or by the presence of higher-order angular multipoles, or both, and discuss implications of our findings for the critical collapse of vacuum gravitational waves.

6.
Appl Opt ; 56(27): 7679-7690, 2017 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-29047754

RESUMO

Transparent objects require acquisition modalities that are very different from the ones used for objects with more diffuse reflectance properties. Digitizing a scene where objects must be acquired with different modalities requires scene reassembly after reconstruction of the object surfaces. This reassembly of a scene that was picked apart for scanning seems unexplored. We contribute with a multimodal digitization pipeline for scenes that require this step of reassembly. Our pipeline includes measurement of bidirectional reflectance distribution functions and high dynamic range imaging of the lighting environment. This enables pixelwise comparison of photographs of the real scene with renderings of the digital version of the scene. Such quantitative evaluation is useful for verifying acquired material appearance and reconstructed surface geometry, which is an important aspect of digital content creation. It is also useful for identifying and improving issues in the different steps of the pipeline. In this work, we use it to improve reconstruction, apply analysis by synthesis to estimate optical properties, and to develop our method for scene reassembly.

7.
Phys Rev Lett ; 116(22): 221103, 2016 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-27314710

RESUMO

We present results from the first fully relativistic simulations of the critical collapse of rotating radiation fluids. We observe critical scaling both in subcritical evolutions-in which case the fluid disperses to infinity and leaves behind flat space-and in supercritical evolutions, which lead to the formation of black holes. We measure the mass and angular momentum of these black holes, and find that both show critical scaling with critical exponents that are consistent with perturbative results. The critical exponents are universal: they are not affected by angular momentum, and are independent of the direction in which the critical curve, which separates subcritical from supercritical evolutions in our two-dimensional parameter space, is crossed. In particular, these findings suggest that the angular momentum decreases more rapidly than the square of the mass, so that, as criticality is approached, the collapse leads to the formation of a nonspinning black hole. We also demonstrate excellent agreement of our numerical data with new closed-form extensions of power-law scalings that describe the mass and angular momentum of rotating black holes formed close to criticality.

8.
Artigo em Inglês | MEDLINE | ID: mdl-38857146

RESUMO

Super resolution ultrasound imaging using the erythrocytes (SURE) has recently been introduced. The method uses erythrocytes as targets instead of fragile microbubbles (MBs). The abundance of erythrocyte scatterers makes it possible to acquire SURE data in just a few seconds compared to several minutes in ultrasound localization microscopy (ULM) using MBs. A high number of scatterers can reduce the acquisition time, however, the tracking of uncorrelated and high-density scatterers is quite challenging. This paper hypothesizes that it is possible to detect and track erythrocytes as targets to obtain vascular flow images. A SURE tracking pipeline is used with modules for beamforming, recursive synthetic aperture imaging, motion estimation, echo canceling, peak detection, and recursive nearest neighbor tracker. The SURE tracking pipeline is capable of distinguishing the flow direction and separating tubes of a simulated Field II phantom with 125 to 25 µm wall-to-wall tube distances, as well as a 3D-printed hydrogel micro-flow phantom with 100 to 60 µm wall-to-wall channel distances. The comparison of an in-vivo SURE scan of a Sprague-Dawley rat kidney with ULM and micro-CT scans with voxel sizes of 26.5µm and 5µm demonstrated consistent findings. A microvascular structure composed of 16 vessels exhibited similarities across all imaging modalities. The flow direction and velocity profiles in the SURE scan were found to be concordant with those from ULM.

9.
Artigo em Inglês | MEDLINE | ID: mdl-38857145

RESUMO

A new approach for vascular super resolution imaging using the erythrocytes as targets (SURE imaging) is described and investigated. SURE imaging does not require fragile contrast agent bubbles, making it possible to use the maximum allowable mechanical index for ultrasound scanning for an increased penetration depth. A synthetic aperture ultrasound sequence was employed with 12 virtual sources using a 10 MHz GE L8-18i-D linear array hockey stick probe. The axial resolution was 1.20λ,(185.0µm) and the lateral resolution was 1.50λ,(231.3µm). Field IIpro simulations were conducted on 12.5 µm radius vessel pairs with varying separations. A vessel pair with a separation of 70 µm could be resolved, indicating a SURE image resolution below half a wavelength. A Verasonics research scanner was used for the in vivo experiments to scan the kidneys of Sprague-Dawley rats for up to 46 s to visualize their microvasculature by processing from 0.1 up to 45 s of data for SURE imaging, and for 46.8 s for super resolution (SR) imaging with a SonoVue contrast agent. Afterward, the renal vasculature was filled with the ex vivo micro-CT contrast agent Microfil, excised, and scanned in a micro-CT scanner at both a 22.6 µm voxel size for 11 hours, and for 20 hours in a 5 µm voxel size for validating the SURE images. Comparing the SURE and micro-CT images revealed that vessels with a diameter of 28 µm, five times smaller than the ultrasound wavelength, could be detected, and the dense grid of microvessels in the full kidney was shown for scan times between 1 to 10 s. The vessel structure in the cortex was also similar for the SURE and SR images. Fourier ring correlation indicated a resolution capability of 29 µm. SURE images are acquired in seconds rather than minutes without any patient preparation or contrast injection, making the method translatable to clinical use.

10.
Neuroinformatics ; 21(2): 269-286, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36809643

RESUMO

Magnetic resonance imaging (MRI) and light-sheet fluorescence microscopy (LSFM) are technologies that enable non-disruptive 3-dimensional imaging of whole mouse brains. A combination of complementary information from both modalities is desirable for studying neuroscience in general, disease progression and drug efficacy. Although both technologies rely on atlas mapping for quantitative analyses, the translation of LSFM recorded data to MRI templates has been complicated by the morphological changes inflicted by tissue clearing and the enormous size of the raw data sets. Consequently, there is an unmet need for tools that will facilitate fast and accurate translation of LSFM recorded brains to in vivo, non-distorted templates. In this study, we have developed a bidirectional multimodal atlas framework that includes brain templates based on both imaging modalities, region delineations from the Allen's Common Coordinate Framework, and a skull-derived stereotaxic coordinate system. The framework also provides algorithms for bidirectional transformation of results obtained using either MR or LSFM (iDISCO cleared) mouse brain imaging while the coordinate system enables users to easily assign in vivo coordinates across the different brain templates.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Animais , Camundongos , Encéfalo/diagnóstico por imagem , Encéfalo/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Mapeamento Encefálico/métodos , Crânio/diagnóstico por imagem
11.
Sci Rep ; 13(1): 7569, 2023 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-37160979

RESUMO

The renal vasculature, acting as a resource distribution network, plays an important role in both the physiology and pathophysiology of the kidney. However, no imaging techniques allow an assessment of the structure and function of the renal vasculature due to limited spatial and temporal resolution. To develop realistic computer simulations of renal function, and to develop new image-based diagnostic methods based on artificial intelligence, it is necessary to have a realistic full-scale model of the renal vasculature. We propose a hybrid framework to build subject-specific models of the renal vascular network by using semi-automated segmentation of large arteries and estimation of cortex area from a micro-CT scan as a starting point, and by adopting the Global Constructive Optimization algorithm for generating smaller vessels. Our results show a close agreement between the reconstructed vasculature and existing anatomical data obtained from a rat kidney with respect to morphometric and hemodynamic parameters.


Assuntos
Terapia de Aceitação e Compromisso , Inteligência Artificial , Animais , Ratos , Artérias , Rim/diagnóstico por imagem , Rim/fisiologia , Microtomografia por Raio-X
12.
Bioelectrochemistry ; 149: 108306, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36345111

RESUMO

The pathophysiological progress of Parkinson's disease leads through degeneration of dopaminergic neurons in the substantia nigra to complete cell death and lack of dopamine in the striatum where it modulates motor functions. Transplantation of dopaminergic stem cell-derived neurons is a possible therapy to restore dopamine levels. We have previously presented multifunctional pyrolytic carbon coated leaky optoelectrical fibers (LOEFs) with laser ablated micro-optical windows (µOWs) as carriers for channelrhodopsin-2 modified optogenetically active neurons for light-induced on-demand dopamine release and amperometric real-time detection. To increase the dopamine release by stimulating a larger neuronal population with light, we present here a novel approach to generate µOWs through laser ablation around the entire circumference of optical fibers to obtain Omni-LOEFs. Cyclic voltammetric characterization of the pyrolytic carbon showed that despite the increased number of µOWs, the electrochemical properties were not deteriorated. Finally, we demonstrate that the current recorded during real-time detection of dopamine upon light-induced stimulation of neurons differentiated on Omni-LOEFs is significantly higher compared to recordings from the same number of cells seeded on LOEFs with µOWs only on one side. Moreover, by varying the cell seeding density, we show that the recorded current is proportional to the dimension of the cell population.


Assuntos
Dopamina , Optogenética , Neurônios/fisiologia , Carbono/metabolismo
13.
Diagnostics (Basel) ; 13(20)2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37892017

RESUMO

Individuals with diabetes at risk of developing diabetic kidney disease (DKD) are challenging to identify using currently available clinical methods. Prognostic accuracy and initiation of treatment could be improved by a quantification of the renal microvascular rarefaction and the increased vascular tortuosity during the development of DKD. Super-resolution ultrasound (SRUS) imaging is an in vivo technique capable of visualizing blood vessels at sizes below 75 µm. This preclinical study aimed to investigate the alterations in renal blood vessels' density and tortuosity in a type 2 diabetes rat model, Zucker diabetic fatty (ZDF) rats, as a prediction of DKD. Lean age-matched Zucker rats were used as controls. A total of 36 rats were studied, subdivided into ages of 12, 22, and 40 weeks. Measured albuminuria indicated the early stage of DKD, and the SRUS was compared with the ex vivo micro-computed tomography (µCT) of the same kidneys. Assessed using the SRUS imaging, a significantly decreased cortical vascular density was detected in the ZDF rats from 22 weeks of age compared to the healthy controls, concomitant with a significantly increased albuminuria. Already by week 12, a trend towards a decreased cortical vascular density was found prior to the increased albuminuria. The quantified vascular density in µCT corresponded with the in vivo SRUS imaging, presenting a consistently lower vascular density in the ZDF rats. Regarding vessel tortuosity, an overall trend towards an increased tortuosity was present in the ZDF rats. SRUS shows promise for becoming an additional tool for monitoring and prognosing DKD. In the future, large-scale animal studies and human trials are needed for confirmation.

14.
Animals (Basel) ; 13(11)2023 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-37889740

RESUMO

Traditional methods for age determination of wildlife include either slicing thin sections off or grinding a tooth, both of which are laborious and invasive. Especially when it comes to ancient and valuable museum samples of rare or extinct species, non-invasive methods are preferable. In this study, X-ray micro-computed tomography (µ-CT) was verified as an alternative non-invasive method for age determination of three species within the order of Carnivora and suborders Odontoceti. Teeth from 13 red foxes (Vulpes vulpes), 2 American mink (Neogale vison), and 2 harbor porpoises (Phocoena phocoena) of known age were studied using µ-CT. The number of visible dental growth layers in the µ-CT were highly correlated with true age for all three species (R2 = 96%, p < 0.001). In addition, the Bland-Altman plot showed high agreement between the age of individuals and visible dental layers represented in 2D slices of the 3D µ-CT images. The true age of individuals was on average 0.3 (±0.6 SD) years higher than the age interpreted by the µ-CT image, and there was a 95% agreement between the true age and the age interpreted from visible dental layers in the µ-CT.

15.
ACS Biomater Sci Eng ; 7(6): 2538-2547, 2021 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-33856194

RESUMO

Microscale devices are promising tools to overcome specific challenges within oral drug delivery. Despite the availability of advanced high-quality imaging techniques, visualization and tracking of microscale devices in the gastrointestinal (GI) tract is still a challenge. This work explores the possibilities of applying planar X-ray imaging and computed tomography (CT) scanning for visualization and tracking of microscale devices in the GI tract of rats. Microcontainers (MCs) are an example of microscale devices that have shown great potential as an oral drug delivery system. Barium sulfate (BaSO4) loaded into the cavity of the MCs increases their overall X-ray contrast, which allows them to be easily tracked. The BaSO4-loaded MCs are quantitatively tracked throughout the entire GI tract of rats by planar X-ray imaging and visualized in 3D by CT scanning. The majority of the BaSO4-loaded MCs are observed to retain in the stomach for 0.5-2 h, enter the cecum after 3-4 h, and leave the cecum and colon 8-10 h post-administration. The imaging approaches can be adopted and used with other types of microscale devices when investigating GI behavior in, for example, preclinical trials and potential clinical studies.


Assuntos
Preparações Farmacêuticas , Tomografia Computadorizada por Raios X , Administração Oral , Animais , Sistemas de Liberação de Medicamentos , Trato Gastrointestinal/diagnóstico por imagem , Ratos , Raios X
16.
Sci Rep ; 11(1): 24335, 2021 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-34934089

RESUMO

Super-resolution ultrasound imaging (SRUS) enables in vivo microvascular imaging of deeper-lying tissues and organs, such as the kidneys or liver. The technique allows new insights into microvascular anatomy and physiology and the development of disease-related microvascular abnormalities. However, the microvascular anatomy is intricate and challenging to depict with the currently available imaging techniques, and validation of the microvascular structures of deeper-lying organs obtained with SRUS remains difficult. Our study aimed to directly compare the vascular anatomy in two in vivo 2D SRUS images of a Sprague-Dawley rat kidney with ex vivo µCT of the same kidney. Co-registering the SRUS images to the µCT volume revealed visually very similar vascular features of vessels ranging from ~ 100 to 1300 µm in diameter and illustrated a high level of vessel branching complexity captured in the 2D SRUS images. Additionally, it was shown that it is difficult to use µCT data of a whole rat kidney specimen to validate the super-resolution capability of our ultrasound scans, i.e., validating the actual microvasculature of the rat kidney. Lastly, by comparing the two imaging modalities, fundamental challenges for 2D SRUS were demonstrated, including the complexity of projecting a 3D vessel network into 2D. These challenges should be considered when interpreting clinical or preclinical SRUS data in future studies.


Assuntos
Imageamento Tridimensional/métodos , Rim/irrigação sanguínea , Rim/diagnóstico por imagem , Ultrassonografia/métodos , Microtomografia por Raio-X/métodos , Animais , Masculino , Microvasos , Ratos , Ratos Sprague-Dawley
17.
PeerJ ; 8: e8850, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32296601

RESUMO

Climate change and invasive species threaten biodiversity, yet rigorous monitoring of their impact can be costly. Citizen science is increasingly used as a tool for monitoring exotic species, because citizens are geographically and temporally dispersed, whereas scientists tend to cluster in museums and at universities. Here we report on the establishment of the first exotic ant taxon (Tetramorium immigrans) in Denmark, which was discovered by children participating in The Ant Hunt. The Ant Hunt is a citizen science project for children that we ran in 2017 and 2018, with a pilot study in 2015. T. immigrans was discovered in the Botanical Garden of the Natural History Museum of Denmark in 2015 and confirmed as established in 2018. This finding extends the northern range boundary of T. immigrans by almost 460 km. Using climatic niche modelling, we compared the climatic niche of T. immigrans in Europe with that of T. caespitum based on confirmed observations from 2006 to 2019. T. immigrans and T. caespitum had a 13% niche overlap, with T. immigrans showing stronger occurrence in warmer and drier areas compared to T. caespitum. Mapping the environmental niches onto geographic space identified several, currently uninhabited, areas as climatically suitable for the establishment of T. immigrans. Tetramorium immigrans was sampled almost three times as often in areas with artificial surfaces compared to T. caespitum, suggesting that T. immigrans may not be native to all of Europe and is being accidentally introduced by humans. Overall, citizen scientists collected data on ants closer to cities and harbours than scientists did and had a stronger bias towards areas of human disturbance. This increased sampling effort in areas of likely introduction of exotic species naturally increases the likelihood of discovering species sooner, making citizen science an excellent tool for exotic species monitoring, as long as trained scientists are involved in the identification process.

18.
ACS Appl Mater Interfaces ; 12(42): 48027-48039, 2020 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-33035422

RESUMO

Today's consumer electronics are made from nonrenewable and toxic components. They are also rigid, bulky, and manufactured in an energy-inefficient manner via CO2-generating routes. Though petroleum-based polymers such as polyethylene terephthalate and polyethylene naphthalate can address the rigidity issue, they have a large carbon footprint and generate harmful waste. Scalable routes for manufacturing electronics that are both flexible and ecofriendly (Fleco) could address the challenges in the field. Ideally, such substrates must incorporate into electronics without compromising device performance. In this work, we demonstrate that a new type of wood-based [nanocellulose (NC)] material made via nanosilicate (NS) reinforcement can yield flexible electronics that can bend and roll without loss of electrical function. Specifically, the NSs interact electrostatically with NC to reinforce thermal and mechanical properties. For instance, films containing 34 wt % of NS displayed an increased young's modulus (1.5 times), thermal stability (290 → 310 °C), and a low coefficient of thermal expansion (40 ppm/K). These films can also easily be separated and renewed into new devices through simple and low-energy processes. Moreover, we used very cheap and environmentally friendly NC from American Value Added Pulping (AVAP) technology, American Process, and therefore, the manufacturing cost of our NS-reinforced NC paper is much cheaper ($0.016 per dm-2) than that of conventional NC-based substrates. Looking forward, the methodology highlighted herein is highly attractive as it can unlock the secrets of Fleco electronics and transform otherwise bulky, rigid, and "difficult-to-process" rigid circuits into more aesthetic and flexible ones while simultaneously bringing relief to an already-overburdened ecosystem.

19.
RSC Adv ; 10(31): 18487-18495, 2020 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-35517184

RESUMO

Monolithic silicon carbide supported ionic liquid-phase (SILP) Rh-catalysts have very recently been introduced for gas-phase hydroformylation as an important step toward industrial upscaling. This study investigates the monolithic catalyst system in combination with different impregnation procedures with non-invasive magnetic resonance imaging (MRI). The findings were supported by X-ray microtomography (micro-CT) data of the monolithic pore structure and a catalytic performance test of the catalyst system for 1-butene gas-phase hydroformylation. MRI confirmed a homogeneous impregnation of the liquid phase throughout the full cross-section of the cylindrical monoliths. Consistent impregnations from one side to the other of the monoliths were achieved with a stabilizer in the system that helped preventing inhomogeneous rim formation. External influences relevant for industrial application, such as long-term storage and temperature exposure, did not affect the homogeneous liquid-phase distribution of the catalyst. The work elucidates important parameters to improve liquid-phase catalyst impregnation to obtain efficient monolithic catalysts for industrial exploitation in gas-phase hydroformylation as well as other important industrial processes.

20.
Lab Chip ; 19(17): 2905-2914, 2019 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-31367713

RESUMO

Microfabrication techniques have been applied to develop micron-scale devices for oral drug delivery with a high degree of control over size, shape and material composition. Recently, microcontainers have been introduced as a novel approach to obtain unidirectional release to avoid luminal drug loss, enhance drug permeation, protect drug payload from the harsh environment of the stomach, and explore the ability for targeted drug delivery. However, in order to eventually pave the way for real life applications of these microfabricated drug delivery systems, it is necessary to fabricate them in biodegradable materials approved for similar applications and with strategies that potentially allow for large scale production. In this study, we for the first time evaluate biodegradable microcontainers for oral drug delivery. Asymmetric poly-ε-caprolactone (PCL) microcontainers with a diameter of 300 µm and a volume of 2.7 nL are fabricated with a novel single-step fabrication process. The microcontainers are loaded with the model drug paracetamol and coated with an enteric pH-sensitive Eudragit® S100 coating to protect the drug until it reaches the desired location in the small intestine. In vitro dissolution studies are performed to assess the drug load and release profile of the PCL microcontainers. Finally, in vivo studies in rats showed a higher bioavailability compared to conventional dosage forms and confirm the potential of biodegradable microcontainers for oral drug delivery.


Assuntos
Acetaminofen/farmacocinética , Sistemas de Liberação de Medicamentos , Microtecnologia , Poliésteres/química , Acetaminofen/administração & dosagem , Acetaminofen/química , Administração Oral , Animais , Liberação Controlada de Fármacos , Masculino , Microtecnologia/instrumentação , Tamanho da Partícula , Poliésteres/administração & dosagem , Ratos , Ratos Sprague-Dawley
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA