Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Can J Urol ; 22(5): 8009-11, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26432975

RESUMO

Ureteral stenosis due to reactivation of the BK virus (BKV) in a state of immunodeficiency is very rare. More common is the appearance of a hemorrhagic cystitis. This report not only shows bilateral ureteral stenosis after bone marrow transplantation, but also presents severe complications as chronic pelvic pain and impaired kidney function as well as irreparable damage to the whole urinary tract leading to nephroureterectomy, subtrigonal cystectomy and orthotopic ileal neobladder. Finally renal transplantation was required. To our knowledge this is the first case in the literature where such a severe course of BKV associated hemorrhagic cystoureteritis is described.


Assuntos
Vírus BK/fisiologia , Transplante de Medula Óssea/efeitos adversos , Cistite/virologia , Infecções por Polyomavirus/complicações , Infecções Tumorais por Vírus/complicações , Ativação Viral , Adolescente , Criança , Constrição Patológica/terapia , Constrição Patológica/virologia , Cistectomia , Cistite/terapia , Feminino , Transtornos Hemorrágicos/terapia , Transtornos Hemorrágicos/virologia , Humanos , Transplante de Rim , Nefrectomia , Ureter/cirurgia , Doenças Ureterais/terapia , Doenças Ureterais/virologia , Obstrução Ureteral/terapia , Obstrução Ureteral/virologia , Coletores de Urina , Adulto Jovem
2.
SAGE Open Med Case Rep ; 7: 2050313X19851379, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31205716

RESUMO

The AMS-800™ artificial urinary sphincter has become the 'gold standard' in the treatment of male stress urinary incontinence. In 2006, the novel artificial urinary sphincter FlowSecure™ containing a stress relief balloon providing low cuff pressures at rest with conditional pressure elevation during periods of stress has been launched. We assessed the intraurethral pressure in the cuff area of the AMS-800 and the FlowSecure by urethral pressure profile in four patients each. Urethral pressure profile was performed at rest and during coughing. In addition, continence situation and patient satisfaction after artificial urinary sphincter implantation was assessed. At rest, median pressure in the cuff region was 74 (38-117, FlowSecure) cm H2O and 102 (95-110, AMS-800) cm H2O. During coughing, pressure peaks rose to 135 (54-162, FlowSecure) cm H2O and 202 (128-216, AMS-800) cm H2O. Median pad usage before artificial urinary sphincter implantation in the FlowSecure and the AMS-800 group was 4 (3-4) and 4.5 (2-6) pads/24 h, respectively. At the time of urodynamic investigation, median pad usage declined to 1.5 (0-4) pads/24 h in the FlowSecure and to 1 (1-2) pads/24 h in the AMS-800 group. Seven of eight patients reported on a satisfactory quality of life, and one patient remained unhappy after FlowSecure implantation. It remains unclear if the trade-off in favour of lower cuff pressures, and consecutively lower intraurethral pressures, holds truly long-term benefits regarding device revision, explantation and patient satisfaction.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA