RESUMO
OBJECTIVE: The aim of this study was to report further experience with transcatheter closure of the patent ductus arteriosus (PDA) using the Amplatzer duct occluder (ADO). BACKGROUND: The design of previously used devices is not ideal for this purpose, and their use has been associated with several drawbacks, especially in large PDAs. METHODS: Forty-three patients, aged 0.3 to 33 years (mean 6.4+/-6.7 years), with a moderate to large, type A to E PDA, underwent attempted transcatheter closure using the ADO. The device is a plug-shaped repositionable occluder made of 0.004-in. nitinol wire mesh. It is delivered through a 5F to 6F long sheath. The mean PDA diameter (at the pulmonary end) was 3.9+/-1.2 mm (range 2.2 to 8 mm). All patients had color flow echocardiographic follow-up (6 to 24 months) at 24 h, 1 and 3 months after closure, and at 6-month intervals thereafter. RESULTS: The mean ADO diameter was 6.1+/-1.4 mm (range 4 to 10 mm). Complete angiographic closure was seen in 40 of 43 patients (93%; 95% confidence interval [CI] 85.4% to 100%). The remaining three patients had a trivial angiographic shunt through the ADO. At 24 h, color flow mapping revealed no shunt in all patients. A 9F long sheath was required for repositioning of a misplaced 8-mm device into the pulmonary artery. The mean fluoroscopy time was 7.9+/-1.6 min (range 4.6 to 12 min). There were no complications. No obstruction of the descending aorta or the pulmonary artery branches was noted on Doppler follow-up studies. Neither thromboembolization nor hemolysis or device failure was encountered. CONCLUSIONS: Transcatheter closure using the ADO is an effective and safe therapy for the majority of patients with patency of the arterial duct. Further studies are required to establish long-term results in a larger patient population.
Assuntos
Ligas , Permeabilidade do Canal Arterial/terapia , Embolização Terapêutica/instrumentação , Adolescente , Adulto , Aortografia , Criança , Pré-Escolar , Permeabilidade do Canal Arterial/diagnóstico por imagem , Desenho de Equipamento , Feminino , Humanos , Lactente , Masculino , RetratamentoRESUMO
Adenovirus is a frequent cause of mild self-limiting upper respiratory tract infection, gastroenteritis, and conjunctivitis in infants and young children. Fatal infections (severe pneumonia progressing to respiratory failure, septic shock and/or encephalitis) are rare among immunocompetent adults. We report a case of severe adenovirus pneumonia in a young immunocompetent male who presented with sudden onset respiratory distress that progressed rapidly to respiratory failure and made a successful recovery on supportive measures. Systematic review of the literature identified 14 cases of severe adenovirus pneumonia (defined as respiratory failure requiring ventilatory support at any point during the course of illness) in otherwise healthy immunocompetent adults both in epidemic and community settings. We describe the clinical characteristics, radiological features, and outcome of identified cases.
Assuntos
Infecções por Adenoviridae/virologia , Adenoviridae/isolamento & purificação , Pneumonia Viral/virologia , Infecções por Adenoviridae/complicações , Infecções por Adenoviridae/terapia , Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pneumonia Viral/complicações , Pneumonia Viral/terapia , Respiração Artificial , Insuficiência Respiratória , Ventiladores MecânicosRESUMO
Between May 1997 and June 2000, 69 patients, ages 0.1 to 34 years, underwent attempted anterograde transcatheter closure of a patent ductus arteriosus (PDA) using the Amplatzer Duct Occluder (ADO). The ADO is a cone-shaped, self-centering, and repositionable occluder made of nitinol wire mesh. A 5Fr to 7Fr sheath was used for the delivery of the device. The mean PDA diameter (at the pulmonary end) was 4.6 +/- 1.9 mm (range 1 mm-8.5 mm). Sixty-seven of the 69 patients had successful device placement. The mean ADO smallest diameter was 6.9 +/- 1.8 mm (range 4 mm-12 mm). Complete angiographic closure occurred in 62 (92.5%) of 67 patients (95% confidence interval, 88.22%-98.77%). In five patients, there was a trivial residual shunt immediately after the procedure. At 24 hours, color Doppler flow imaging revealed complete closure in all 67 (100%) patients. The unsuccessful attempts occurred in two patients with a small, 1-mm diameter native PDA and residual PDA after surgical occlusion. Fluoroscopy time was 7.6 +/- 1.8 minutes (4 min-18 min). No complications were observed. At a median follow-up of 1.5 years (range 0.25 to 3.2 years), all patients had complete closure without complications. We conclude that transcatheter closure using the ADO is a highly effective and safe treatment for most patients with PDA.
Assuntos
Permeabilidade do Canal Arterial/terapia , Embolização Terapêutica/instrumentação , Embolização Terapêutica/métodos , Adolescente , Adulto , Criança , Pré-Escolar , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Lactente , Recém-Nascido , MasculinoRESUMO
Nutritional deficiency continues to be an important cause of rickets in the underdeveloped and developing parts of the world. In the western hemisphere, predominantly non-nutritional forms of rickets and osteomalacia are now seen. In this report we discuss a family with X-linked hypophosphataemic rickets from the Kashmir region of the Indian subcontinent (which is an uncommon entity here).