Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Nature ; 577(7788): 89-94, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31894144

RESUMO

Screening mammography aims to identify breast cancer at earlier stages of the disease, when treatment can be more successful1. Despite the existence of screening programmes worldwide, the interpretation of mammograms is affected by high rates of false positives and false negatives2. Here we present an artificial intelligence (AI) system that is capable of surpassing human experts in breast cancer prediction. To assess its performance in the clinical setting, we curated a large representative dataset from the UK and a large enriched dataset from the USA. We show an absolute reduction of 5.7% and 1.2% (USA and UK) in false positives and 9.4% and 2.7% in false negatives. We provide evidence of the ability of the system to generalize from the UK to the USA. In an independent study of six radiologists, the AI system outperformed all of the human readers: the area under the receiver operating characteristic curve (AUC-ROC) for the AI system was greater than the AUC-ROC for the average radiologist by an absolute margin of 11.5%. We ran a simulation in which the AI system participated in the double-reading process that is used in the UK, and found that the AI system maintained non-inferior performance and reduced the workload of the second reader by 88%. This robust assessment of the AI system paves the way for clinical trials to improve the accuracy and efficiency of breast cancer screening.


Assuntos
Inteligência Artificial/normas , Neoplasias da Mama/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Detecção Precoce de Câncer/normas , Feminino , Humanos , Mamografia/normas , Reprodutibilidade dos Testes , Reino Unido , Estados Unidos
2.
Breast Cancer Res ; 26(1): 85, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38807211

RESUMO

BACKGROUND: Abbreviated breast MRI (FAST MRI) is being introduced into clinical practice to screen women with mammographically dense breasts or with a personal history of breast cancer. This study aimed to optimise diagnostic accuracy through the adaptation of interpretation-training. METHODS: A FAST MRI interpretation-training programme (short presentations and guided hands-on workstation teaching) was adapted to provide additional training during the assessment task (interpretation of an enriched dataset of 125 FAST MRI scans) by giving readers feedback about the true outcome of each scan immediately after each scan was interpreted (formative assessment). Reader interaction with the FAST MRI scans used developed software (RiViewer) that recorded reader opinions and reading times for each scan. The training programme was additionally adapted for remote e-learning delivery. STUDY DESIGN: Prospective, blinded interpretation of an enriched dataset by multiple readers. RESULTS: 43 mammogram readers completed the training, 22 who interpreted breast MRI in their clinical role (Group 1) and 21 who did not (Group 2). Overall sensitivity was 83% (95%CI 81-84%; 1994/2408), specificity 94% (95%CI 93-94%; 7806/8338), readers' agreement with the true outcome kappa = 0.75 (95%CI 0.74-0.77) and diagnostic odds ratio = 70.67 (95%CI 61.59-81.09). Group 1 readers showed similar sensitivity (84%) to Group 2 (82% p = 0.14), but slightly higher specificity (94% v. 93%, p = 0.001). Concordance with the ground truth increased significantly with the number of FAST MRI scans read through the formative assessment task (p = 0.002) but by differing amounts depending on whether or not a reader had previously attended FAST MRI training (interaction p = 0.02). Concordance with the ground truth was significantly associated with reading batch size (p = 0.02), tending to worsen when more than 50 scans were read per batch. Group 1 took a median of 56 seconds (range 8-47,466) to interpret each FAST MRI scan compared with 78 (14-22,830, p < 0.0001) for Group 2. CONCLUSIONS: Provision of immediate feedback to mammogram readers during the assessment test set reading task increased specificity for FAST MRI interpretation and achieved high diagnostic accuracy. Optimal reading-batch size for FAST MRI was 50 reads per batch. Trial registration (25/09/2019): ISRCTN16624917.


Assuntos
Neoplasias da Mama , Curva de Aprendizado , Imageamento por Ressonância Magnética , Mamografia , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Pessoa de Meia-Idade , Detecção Precoce de Câncer/métodos , Estudos Prospectivos , Idoso , Sensibilidade e Especificidade , Interpretação de Imagem Assistida por Computador/métodos , Mama/diagnóstico por imagem , Mama/patologia
3.
Breast Cancer Res ; 24(1): 55, 2022 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-35907862

RESUMO

BACKGROUND: Abbreviated breast MRI (abMRI) is being introduced in breast screening trials and clinical practice, particularly for women with dense breasts. Upscaling abMRI provision requires the workforce of mammogram readers to learn to effectively interpret abMRI. The purpose of this study was to examine the diagnostic accuracy of mammogram readers to interpret abMRI after a single day of standardised small-group training and to compare diagnostic performance of mammogram readers experienced in full-protocol breast MRI (fpMRI) interpretation (Group 1) with that of those without fpMRI interpretation experience (Group 2). METHODS: Mammogram readers were recruited from six NHS Breast Screening Programme sites. Small-group hands-on workstation training was provided, with subsequent prospective, independent, blinded interpretation of an enriched dataset with known outcome. A simplified form of abMRI (first post-contrast subtracted images (FAST MRI), displayed as maximum-intensity projection (MIP) and subtracted slice stack) was used. Per-breast and per-lesion diagnostic accuracy analysis was undertaken, with comparison across groups, and double-reading simulation of a consecutive screening subset. RESULTS: 37 readers (Group 1: 17, Group 2: 20) completed the reading task of 125 scans (250 breasts) (total = 9250 reads). Overall sensitivity was 86% (95% confidence interval (CI) 84-87%; 1776/2072) and specificity 86% (95%CI 85-86%; 6140/7178). Group 1 showed significantly higher sensitivity (843/952; 89%; 95%CI 86-91%) and higher specificity (2957/3298; 90%; 95%CI 89-91%) than Group 2 (sensitivity = 83%; 95%CI 81-85% (933/1120) p < 0.0001; specificity = 82%; 95%CI 81-83% (3183/3880) p < 0.0001). Inter-reader agreement was higher for Group 1 (kappa = 0.73; 95%CI 0.68-0.79) than for Group 2 (kappa = 0.51; 95%CI 0.45-0.56). Specificity improved for Group 2, from the first 55 cases (81%) to the remaining 70 (83%) (p = 0.02) but not for Group 1 (90-89% p = 0.44), whereas sensitivity remained consistent for both Group 1 (88-89%) and Group 2 (83-84%). CONCLUSIONS: Single-day abMRI interpretation training for mammogram readers achieved an overall diagnostic performance within benchmarks published for fpMRI but was insufficient for diagnostic accuracy of mammogram readers new to breast MRI to match that of experienced fpMRI readers. Novice MRI reader performance improved during the reading task, suggesting that additional training could further narrow this performance gap.


Assuntos
Neoplasias da Mama , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Estudos Prospectivos , Sensibilidade e Especificidade
5.
Eur Radiol ; 26(3): 874-83, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26105023

RESUMO

OBJECTIVE: To compare the performance of different types of detectors in breast cancer detection. METHODS: A mammography image set containing subtle malignant non-calcification lesions, biopsy-proven benign lesions, simulated malignant calcification clusters and normals was acquired using amorphous-selenium (a-Se) detectors. The images were adapted to simulate four types of detectors at the same radiation dose: digital radiography (DR) detectors with a-Se and caesium iodide (CsI) convertors, and computed radiography (CR) detectors with a powder phosphor (PIP) and a needle phosphor (NIP). Seven observers marked suspicious and benign lesions. Analysis was undertaken using jackknife alternative free-response receiver operating characteristics weighted figure of merit (FoM). The cancer detection fraction (CDF) was estimated for a representative image set from screening. RESULTS: No significant differences in the FoMs between the DR detectors were measured. For calcification clusters and non-calcification lesions, both CR detectors' FoMs were significantly lower than for DR detectors. The calcification cluster's FoM for CR NIP was significantly better than for CR PIP. The estimated CDFs with CR PIP and CR NIP detectors were up to 15% and 22% lower, respectively, than for DR detectors. CONCLUSION: Cancer detection is affected by detector type, and the use of CR in mammography should be reconsidered. KEY POINTS: The type of mammography detector can affect the cancer detection rates. CR detectors performed worse than DR detectors in mammography. Needle phosphor CR performed better than powder phosphor CR. Calcification clusters detection is more sensitive to detector type than other cancers.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Mamografia/instrumentação , Idoso , Detecção Precoce de Câncer/instrumentação , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Mamografia/métodos , Programas de Rastreamento/instrumentação , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Agulhas , Variações Dependentes do Observador , Curva ROC , Intensificação de Imagem Radiográfica/métodos
6.
Eur Respir J ; 56(2)2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32616598
7.
AJR Am J Roentgenol ; 203(2): 387-93, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25055275

RESUMO

OBJECTIVE. The objective of our study was to investigate the effect of image processing on the detection of cancers in digital mammography images. MATERIALS AND METHODS. Two hundred seventy pairs of breast images (both breasts, one view) were collected from eight systems using Hologic amorphous selenium detectors: 80 image pairs showed breasts containing subtle malignant masses; 30 image pairs, biopsy-proven benign lesions; 80 image pairs, simulated calcification clusters; and 80 image pairs, no cancer (normal). The 270 image pairs were processed with three types of image processing: standard (full enhancement), low contrast (intermediate enhancement), and pseudo-film-screen (no enhancement). Seven experienced observers inspected the images, locating and rating regions they suspected to be cancer for likelihood of malignancy. The results were analyzed using a jackknife-alternative free-response receiver operating characteristic (JAFROC) analysis. RESULTS. The detection of calcification clusters was significantly affected by the type of image processing: The JAFROC figure of merit (FOM) decreased from 0.65 with standard image processing to 0.63 with low-contrast image processing (p = 0.04) and from 0.65 with standard image processing to 0.61 with film-screen image processing (p = 0.0005). The detection of noncalcification cancers was not significantly different among the image-processing types investigated (p > 0.40). CONCLUSION. These results suggest that image processing has a significant impact on the detection of calcification clusters in digital mammography. For the three image-processing versions and the system investigated, standard image processing was optimal for the detection of calcification clusters. The effect on cancer detection should be considered when selecting the type of image processing in the future.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Biópsia , Feminino , Humanos , Pessoa de Meia-Idade , Reino Unido
8.
Nucleic Acids Res ; 40(Database issue): D947-56, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22013161

RESUMO

canSAR is a fully integrated cancer research and drug discovery resource developed to utilize the growing publicly available biological annotation, chemical screening, RNA interference screening, expression, amplification and 3D structural data. Scientists can, in a single place, rapidly identify biological annotation of a target, its structural characterization, expression levels and protein interaction data, as well as suitable cell lines for experiments, potential tool compounds and similarity to known drug targets. canSAR has, from the outset, been completely use-case driven which has dramatically influenced the design of the back-end and the functionality provided through the interfaces. The Web interface at http://cansar.icr.ac.uk provides flexible, multipoint entry into canSAR. This allows easy access to the multidisciplinary data within, including target and compound synopses, bioactivity views and expert tools for chemogenomic, expression and protein interaction network data.


Assuntos
Antineoplásicos/química , Bases de Dados Genéticas , Neoplasias/genética , Neoplasias/metabolismo , Antineoplásicos/farmacologia , Linhagem Celular Tumoral , Descoberta de Drogas , Expressão Gênica , Variação Genética , Humanos , Internet , Modelos Moleculares , Mapas de Interação de Proteínas , Interferência de RNA , Integração de Sistemas , Pesquisa Translacional Biomédica
9.
Radiol Artif Intell ; : e230431, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38775671

RESUMO

"Just Accepted" papers have undergone full peer review and have been accepted for publication in Radiology: Artificial Intelligence. This article will undergo copyediting, layout, and proof review before it is published in its final version. Please note that during production of the final copyedited article, errors may be discovered which could affect the content. Purpose To develop an artificial intelligence (AI) deep learning tool capable of predicting future breast cancer risk from a current negative screening mammographic examination and to evaluate the model on data from the UK National Health Service Breast Screening Program. Materials and Methods The OPTIMAM Mammography Imaging Database contains screening data, including mammograms and information on interval cancers, for > 300,000 women who attended screening at three different sites in the UK from 2012 onward. Cancer-free screening examinations from women aged 50-70 years were obtained and classified as risk-positive or risk-negative based on the occurrence of cancer within 3 years of the original examination. Examinations with confirmed cancer and images containing implants were excluded. From the resulting 5264 risk-positive and 191488 risk-negative examinations, training (n = 89285) validation (n = 2106) and test (n = 39351) datasets were produced for model development and evaluation. The AI model was trained to predict future cancer occurrence based on screening mammograms and patient age. Performance was evaluated on the test dataset using the area under the receiver operating characteristic curve (AUC) and compared across subpopulations to assess potential biases. Interpretability of the model was explored, including with saliency maps. Results On the hold-out test set, the AI model achieved an overall AUC of 0.70 (95% CI: 0.69, 0.72). There was no evidence of a difference in performance across the three sites, between patient ethnicities or across age-groups Visualization of saliency maps and sample images provided insights into the mammographic features associated with AI-predicted cancer risk. Conclusion The developed AI tool showed good performance on a multisite, UK-specific dataset. ©RSNA, 2024.

10.
Br J Radiol ; 96(1143): 20211104, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36607283

RESUMO

OBJECTIVE: To pilot a process for the independent external validation of an artificial intelligence (AI) tool to detect breast cancer using data from the NHS breast screening programme (NHSBSP). METHODS: A representative data set of mammography images from 26,000 women attending 2 NHS screening centres, and an enriched data set of 2054 positive cases were used from the OPTIMAM image database. The use case of the AI tool was the replacement of the first or second human reader. The performance of the AI tool was compared to that of human readers in the NHSBSP. RESULTS: Recommendations for future external validations of AI tools to detect breast cancer are provided. The tool recalled different breast cancers to the human readers. This study showed the importance of testing AI tools on all types of cases (including non-standard) and the clarity of any warning messages. The acceptable difference in sensitivity and specificity between the AI tool and human readers should be determined. Any information vital for the clinical application should be a required output for the AI tool. It is recommended that the interaction of radiologists with the AI tool, and the effect of the AI tool on arbitration be investigated prior to clinical use. CONCLUSION: This pilot demonstrated several lessons for future independent external validation of AI tools for breast cancer detection. ADVANCES IN KNOWLEDGE: Knowledge has been gained towards best practice procedures for performing independent external validations of AI tools for the detection of breast cancer using data from the NHS Breast Screening Programme.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Neoplasias da Mama/diagnóstico por imagem , Inteligência Artificial , Mamografia/métodos , Mama/diagnóstico por imagem , Reino Unido , Detecção Precoce de Câncer/métodos , Estudos Retrospectivos
11.
Phys Med ; 98: 113-121, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35526372

RESUMO

PURPOSE: To investigate the relationship between age of mammographic x-ray equipment, and number of reported faults and related consequences. METHODS: A centralised online fault reporting database is used by all UK breast screening programmes to collate faults with mammography equipment. Data on faults occurring in 2018 and 2019 for digital x-ray imaging systems were analysed. The effect of the age of mammography systems on the number of equipment faults, and the consequences of these faults was examined. The number of days downtime, number of cancelled appointments, number of repeated images, and number of recalled participants were used to quantify the severity of faults. RESULTS: This analysis covers a two year period and includes 4271 faults and 522 individual x-ray sets. On average, an x-ray set was 6.1 years old at the time when a fault occurred. 77% of x-ray sets experienced five of fewer annual faults. X-ray sets of nine years old had the highest average number of annual faults. Systems of ten years old had the highest average number of days downtime per year, and the highest average number of cancellations per year. The indicated primary use of 48% of the x-ray sets included in this analysis was screening, but a disproportionate 87% of cancelled appointments occurred due to faults on these units compared to those used primarily for assessment, or for a mixture of assessment and screening. CONCLUSIONS: Information from this unique dataset can be used to support guidance on equipment replacement programmes for mammographic x-ray sets.


Assuntos
Neoplasias da Mama , Mamografia , Mama , Criança , Feminino , Humanos , Mamografia/métodos , Programas de Rastreamento , Intensificação de Imagem Radiográfica , Raios X
12.
Brief Bioinform ; 10(3): 330-40, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19383844

RESUMO

Vaccine research is a combinatorial science requiring computational analysis of vaccine components, formulations and optimization. We have developed a framework that combines computational tools for the study of immune function and vaccine development. This framework, named ImmunoGrid combines conceptual models of the immune system, models of antigen processing and presentation, system-level models of the immune system, Grid computing, and database technology to facilitate discovery, formulation and optimization of vaccines. ImmunoGrid modules share common conceptual models and ontologies. The ImmunoGrid portal offers access to educational simulators where previously defined cases can be displayed, and to research simulators that allow the development of new, or tuning of existing, computational models. The portal is accessible at .


Assuntos
Sistemas Computacionais , Desenho de Fármacos , Sistema Imunitário/fisiologia , Modelos Biológicos , Vacinas , Biologia Computacional/métodos , Sistemas de Gerenciamento de Base de Dados , Bases de Dados Factuais , Humanos , Complexo Principal de Histocompatibilidade , Integração de Sistemas
13.
Gigascience ; 10(11)2021 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-34849869

RESUMO

BACKGROUND: The National COVID-19 Chest Imaging Database (NCCID) is a centralized database containing mainly chest X-rays and computed tomography scans from patients across the UK. The objective of the initiative is to support a better understanding of the coronavirus SARS-CoV-2 disease (COVID-19) and the development of machine learning technologies that will improve care for patients hospitalized with a severe COVID-19 infection. This article introduces the training dataset, including a snapshot analysis covering the completeness of clinical data, and availability of image data for the various use-cases (diagnosis, prognosis, longitudinal risk). An additional cohort analysis measures how well the NCCID represents the wider COVID-19-affected UK population in terms of geographic, demographic, and temporal coverage. FINDINGS: The NCCID offers high-quality DICOM images acquired across a variety of imaging machinery; multiple time points including historical images are available for a subset of patients. This volume and variety make the database well suited to development of diagnostic/prognostic models for COVID-associated respiratory conditions. Historical images and clinical data may aid long-term risk stratification, particularly as availability of comorbidity data increases through linkage to other resources. The cohort analysis revealed good alignment to general UK COVID-19 statistics for some categories, e.g., sex, whilst identifying areas for improvements to data collection methods, particularly geographic coverage. CONCLUSION: The NCCID is a growing resource that provides researchers with a large, high-quality database that can be leveraged both to support the response to the COVID-19 pandemic and as a test bed for building clinically viable medical imaging models.


Assuntos
COVID-19 , Estudos de Coortes , Confiabilidade dos Dados , Humanos , Pandemias , SARS-CoV-2 , Tomografia Computadorizada por Raios X
15.
Digit Health ; 7: 20552076211048654, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34868617

RESUMO

The prevalence of the coronavirus SARS-CoV-2 disease has resulted in the unprecedented collection of health data to support research. Historically, coordinating the collation of such datasets on a national scale has been challenging to execute for several reasons, including issues with data privacy, the lack of data reporting standards, interoperable technologies, and distribution methods. The coronavirus SARS-CoV-2 disease pandemic has highlighted the importance of collaboration between government bodies, healthcare institutions, academic researchers and commercial companies in overcoming these issues during times of urgency. The National COVID-19 Chest Imaging Database, led by NHSX, British Society of Thoracic Imaging, Royal Surrey NHS Foundation Trust and Faculty, is an example of such a national initiative. Here, we summarise the experiences and challenges of setting up the National COVID-19 Chest Imaging Database, and the implications for future ambitions of national data curation in medical imaging to advance the safe adoption of artificial intelligence in healthcare.

16.
BMC Bioinformatics ; 9: 407, 2008 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-18831735

RESUMO

BACKGROUND: An increasing number of scientific research projects require access to large-scale computational resources. This is particularly true in the biological field, whether to facilitate the analysis of large high-throughput data sets, or to perform large numbers of complex simulations - a characteristic of the emerging field of systems biology. RESULTS: In this paper we present a lightweight generic framework for combining disparate computational resources at multiple sites (ranging from local computers and clusters to established national Grid services). A detailed guide describing how to set up the framework is available from the following URL: http://igrid-ext.cryst.bbk.ac.uk/portal_guide/. CONCLUSION: This approach is particularly (but not exclusively) appropriate for large-scale biology projects with multiple collaborators working at different national or international sites. The framework is relatively easy to set up, hides the complexity of Grid middleware from the user, and provides access to resources through a single, uniform interface. It has been developed as part of the European ImmunoGrid project.


Assuntos
Biologia/métodos , Sistema Imunitário/imunologia , Internet , Modelos Imunológicos , Projetos de Pesquisa , Biologia de Sistemas/métodos , Simulação por Computador
17.
J Mol Graph Model ; 26(6): 957-61, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17766153

RESUMO

Epitopes mediated by T cells lie at the heart of the adaptive immune response and form the essential nucleus of anti-tumour peptide or epitope-based vaccines. Antigenic T cell epitopes are mediated by major histocompatibility complex (MHC) molecules, which present them to T cell receptors. Calculating the affinity between a given MHC molecule and an antigenic peptide using experimental approaches is both difficult and time consuming, thus various computational methods have been developed for this purpose. A server has been developed to allow a structural approach to the problem by generating specific MHC:peptide complex structures and providing configuration files to run molecular modelling simulations upon them. A system has been produced which allows the automated construction of MHC:peptide structure files and the corresponding configuration files required to execute a molecular dynamics simulation using NAMD. The system has been made available through a web-based front end and stand-alone scripts. Previous attempts at structural prediction of MHC:peptide affinity have been limited due to the paucity of structures and the computational expense in running large scale molecular dynamics simulations. The MHCsim server (http://igrid-ext.cryst.bbk.ac.uk/MHCsim) allows the user to rapidly generate any desired MHC:peptide complex and will facilitate molecular modelling simulation of MHC complexes on an unprecedented scale.


Assuntos
Simulação por Computador , Epitopos de Linfócito T/imunologia , Complexo Principal de Histocompatibilidade/imunologia , Peptídeos/química , Termodinâmica , Animais , Cristalografia por Raios X , Humanos , Modelos Moleculares , Reprodutibilidade dos Testes , Design de Software
18.
Methods Mol Biol ; 453: 451-70, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18712319

RESUMO

Many bioinformatics tasks involve creating a computational pipeline from existing software components and algorithms. The traditional approach is to glue components together using scripts written in a programming language such as Perl. However, a new, more powerful approach is emerging that promises to revolutionise the way bioinformaticians create applications from existing components, an approach based on the concept of the scientific workflow. Scientific workflows are created in graphical environments known as workflow management systems. They have many benefits over traditional program scripts, including speed of development, portability, and their suitability for developing complex, distributed applications. This chapter explains how to design and implement bioinformatics workflows using free, Open Source software tools, such as the Taverna workflow management system. We also demonstrate how new and existing tools can be deployed as Web services so that they can be easily integrated into novel computational pipelines using the scientific workflow paradigm.


Assuntos
Biologia Computacional/métodos , Metodologias Computacionais , Armazenamento e Recuperação da Informação , Software , Interface Usuário-Computador
19.
Nucleic Acids Res ; 32(8): 2618-22, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15141032

RESUMO

A web server has been developed to access annotation and graphical reports of synteny and gene order between the Fugu genome and human genes. In this system, the assembled Fugu genomic sequences (also known as scaffolds) are annotated. The annotations for each Fugu scaffold are computed, stored and made publicly available. The annotations describe matches to human homologous genes. For each significant human gene match on the Fugu scaffold, the corresponding human chromosome map and measures of the significance of each match are given. The web-based server provides public access to these annotations and graphical displays of the results. The user is provided with a selection of views including a chromosome-colour-coded image and a table containing the details of the matches. The Fugu-Human Genome Synteny Viewer has been tested by comparing results with examples from a paper that includes a study of transcription factors, Fos and Jun encoding regions. The Fugu-human genome synteny views are available for each Fugu scaffold through the clonesearch web page located at the Fugu Genomics website (http://fugu.rfcgr.mrc.ac.uk/).


Assuntos
Genoma Humano , Software , Sintenia , Takifugu/genética , Animais , Sequência de Bases , Gráficos por Computador , Ordem dos Genes , Genes jun , Genoma , Humanos , Internet
20.
Phys Med ; 32(4): 568-74, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27061872

RESUMO

PURPOSE: To investigate the relationship between image quality measurements and the clinical performance of digital mammographic systems. METHODS: Mammograms containing subtle malignant non-calcification lesions and simulated malignant calcification clusters were adapted to appear as if acquired by four types of detector. Observers searched for suspicious lesions and gave these a malignancy score. Analysis was undertaken using jackknife alternative free-response receiver operating characteristics weighted figure of merit (FoM). Images of a CDMAM contrast-detail phantom were adapted to appear as if acquired using the same four detectors as the clinical images. The resultant threshold gold thicknesses were compared to the FoMs using a linear regression model and an F-test was used to find if the gradient of the relationship was significantly non-zero. RESULTS: The detectors with the best image quality measurement also had the highest FoM values. The gradient of the inverse relationship between FoMs and threshold gold thickness for the 0.25mm diameter disk was significantly different from zero for calcification clusters (p=0.027), but not for non-calcification lesions (p=0.11). Systems performing just above the minimum image quality level set in the European Guidelines for Quality Assurance in Breast Cancer Screening and Diagnosis resulted in reduced cancer detection rates compared to systems performing at the achievable level. CONCLUSIONS: The clinical effectiveness of mammography for the task of detecting calcification clusters was found to be linked to image quality assessment using the CDMAM phantom. The European Guidelines should be reviewed as the current minimum image quality standards may be too low.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Neoplasias da Mama/metabolismo , Neoplasias da Mama/patologia , Calcinose/diagnóstico por imagem , Calcinose/metabolismo , Calcinose/patologia , Feminino , Guias como Assunto , Humanos , Mamografia/normas , Intensificação de Imagem Radiográfica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA