Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
BMC Med Imaging ; 20(1): 86, 2020 07 29.
Artigo em Inglês | MEDLINE | ID: mdl-32727387

RESUMO

BACKGROUND: BRCA1/2 deleterious variants account for most of the hereditary breast and ovarian cancer cases. Prediction models and guidelines for the assessment of genetic risk rely heavily on criteria with high variability such as family cancer history. Here we investigated the efficacy of MRI (magnetic resonance imaging) texture features as a predictor for BRCA mutation status. METHODS: A total of 41 female breast cancer individuals at high genetic risk, sixteen with a BRCA1/2 pathogenic variant and twenty five controls were included. From each MRI 4225 computer-extracted voxels were analyzed. Non-imaging features including clinical, family cancer history variables and triple negative receptor status (TNBC) were complementarily used. Lasso-principal component regression (L-PCR) analysis was implemented to compare the predictive performance, assessed as area under the curve (AUC), when imaging features were used, and lasso logistic regression or conventional logistic regression for the remaining analyses. RESULTS: Lasso-selected imaging principal components showed the highest predictive value (AUC 0.86), surpassing family cancer history. Clinical variables comprising age at disease onset and bilateral breast cancer yielded a relatively poor AUC (~ 0.56). Combination of imaging with the non-imaging variables led to an improvement of predictive performance in all analyses, with TNBC along with the imaging components yielding the highest AUC (0.94). Replacing family history variables with imaging components yielded an improvement of classification performance of ~ 4%, suggesting that imaging compensates the predictive information arising from family cancer structure. CONCLUSIONS: The L-PCR model uncovered evidence for the utility of MRI texture features in distinguishing between BRCA1/2 positive and negative high-risk breast cancer individuals, which may suggest value to diagnostic routine. Integration of computer-extracted texture analysis from MRI modalities in prediction models and inclusion criteria might play a role in reducing false positives or missed cases especially when established risk variables such as family history are missing.


Assuntos
Proteína BRCA1/genética , Proteína BRCA2/genética , Síndrome Hereditária de Câncer de Mama e Ovário/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Neoplasias de Mama Triplo Negativas/diagnóstico por imagem , Adulto , Estudos de Casos e Controles , Feminino , Variação Genética , Síndrome Hereditária de Câncer de Mama e Ovário/genética , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes , Análise de Regressão , Medição de Risco , Neoplasias de Mama Triplo Negativas/genética
2.
Pediatr Radiol ; 50(9): 1240-1248, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32556576

RESUMO

BACKGROUND: Radiation dose at CT should be as low as possible without compromising diagnostic quality. OBJECTIVE: To assess the potential for maximum dose reduction of pediatric lung dual-source CT with spectral shaping and advanced iterative reconstruction (ADMIRE). MATERIALS AND METHODS: We retrospectively analyzed dual-source CT acquisitions in a full-dose group (FD: 100 kV, 64 reference mAs) and in three groups with spectral shaping and differing reference mAs values (Sn: 100 kV, 96/64/32 reference mAs), each group consisting of 16 patients (age mean 11.5 years, standard deviation 4.8 years, median 12.8 years, range 1.3-18 years). Advanced iterative reconstruction of images was performed with different strengths (FD: ADMIRE Level 2; Sn: ADMIRE Levels 2, 3 and 4). We analyzed dose parameters and measured noise. Diagnostic confidence and detectability of lung lesions as well as anatomical structures were assessed using a Likert scale (from 1 [unacceptable] to 4 [fully acceptable]). RESULTS: Compared to full dose, effective dose was reduced to 16.7% in the Sn 96 group, 11.1% in Sn64, and 5.5% in Sn32 (P<0.001). Noise values of Sn64ADM4 did not statistically differ from those in FDADM2 (45.7 vs. 38.9 Hounsfield units [HU]; P=0.132), whereas noise was significantly higher in Sn32ADM4 compared to Sn64ADM4 (61.5 HU; P<0.001). A Likert score >3 was reached in Sn64ADM4 regarding diagnostic confidence (3.2) and detectability of lung lesions (3.3). For detectability of most anatomical structures, no significant differences were found between FDAM2 and Sn64ADM4 (P≥0.05). CONCLUSION: In pediatric lung dual-source CT, spectral shaping together with ADMIRE 4 enable radiation dose reduction to about 10% of a full-dose protocol while maintaining an acceptable diagnostic quality.


Assuntos
Pneumopatias/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X/métodos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos
3.
BMC Med Imaging ; 19(1): 3, 2019 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-30612560

RESUMO

BACKGROUND: Peripherally inserted central catheters (PICCs) provide secure intravenous access for the delivery of life-sustaining medications and nutrition. They are commonly used in pediatrics. Confirmation of correct central catheter tip position is crucial. Verification is usually done by a radiograph. The aim of this study is to evaluate the ability of Fractional Multiscale image Processing (FMP) to detect PICC tips on the digital chest radiographs of neonates. METHODS: A total of 94 radiographs of 47 patients were included in the study. 29 patients were male, 18 were female. The mean age of all examined children was 9.2 days (range 0-99 days). In total, six readers (two radiologists, two residents in radiology, one last year medical student, one neonatologist) evaluated 94 unprocessed and catheter-enhanced radiographs using a 5-point Likert scale (1 = poor catheter tip visualization, 5 = excellent catheter tip visualization). Additionally, the two radiologists evaluated the diagnostic confidence for chest pathologies using a 5-point Likert scale (1 = poor diagnostic confidence, 5 = excellent diagnostic confidence). Radiographs were evaluated on a dedicated workstation. RESULTS: In all cases, the catheter-enhanced radiograph rated higher than (n = 471), or equal (n = 93) to, the unprocessed radiograph when visualizing catheter tips. 87% of the catheter-enhanced radiographs obtained a rating of 4 or higher, while only 42% of unprocessed radiographs received 4 or more points. Regarding diagnostic confidence for chest pathologies one radiologist rated two catheter-enhanced radiographs higher than the unprocessed radiographs, while all other 186 evaluations rated the catheter-enhanced radiographs equal to (n = 78) or lower than (n = 108) the unprocessed radiographs. Only 60% of the catheter-enhanced radiographs yielded a diagnostic confidence of 4 or higher, while 90% of the unprocessed images received 4 or more points. CONCLUSION: Catheter-enhanced digital chest radiographs demonstrate improved visualization of low contrast PICC tips in neonates compared to unprocessed radiographs. Furthermore, they enable detection of accompanying chest pathologies. However, definitive diagnosis of chest pathologies should be made on unprocessed radiographs.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Radiografia Torácica/instrumentação , Cateterismo Periférico , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Radiografia Torácica/métodos
4.
Kidney Int ; 93(5): 1191-1197, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29455909

RESUMO

Long-term elevated blood sugar levels result in tissue matrix compositional changes in patients with diabetes mellitus type 2 (T2DM). We hypothesized that hemodialysis patients with T2DM might accumulate more tissue sodium than control hemodialysis patients. To test this, 23Na magnetic resonance imaging (23Na MRI) was used to estimate sodium in skin and muscle tissue in hemodialysis patients with or without T2DM. Muscle fat content was estimated by 1H MRI and tissue sodium content by 23Na MRI pre- and post-hemodialysis in ten hemodialysis patients with T2DM and in 30 matched control hemodialysis patients. We also assessed body fluid distribution with the Body Composition Monitor. 1H MRI indicated a tendency to higher muscle fat content in hemodialysis patients with T2DM compared to non-diabetic hemodialysis patients. 23Na MRI indicated increased sodium content in muscle and skin tissue of hemodialysis patients with T2DM compared to control hemodialysis patients. Multi-frequency bioimpedance was used to estimate extracellular water (ECW), and excess ECW in T2DM hemodialysis patients correlated with HbA1c levels. Sodium mobilization during hemodialysis lowered muscle sodium content post-dialysis to a greater degree in T2DM hemodialysis patients than in control hemodialysis patients. Thus, our findings provide evidence that increased sodium accumulation occurs in hemodialysis patients with T2DM and that impaired serum glucose metabolism is associated with disturbances in tissue sodium and water content.


Assuntos
Composição Corporal , Diabetes Mellitus Tipo 2/diagnóstico por imagem , Nefropatias Diabéticas/terapia , Imageamento por Ressonância Magnética , Músculo Esquelético/diagnóstico por imagem , Compostos Radiofarmacêuticos/metabolismo , Diálise Renal , Pele/diagnóstico por imagem , Isótopos de Sódio/metabolismo , Adiposidade , Idoso , Glicemia/metabolismo , Compartimentos de Líquidos Corporais/diagnóstico por imagem , Compartimentos de Líquidos Corporais/metabolismo , Estudos de Casos e Controles , Diabetes Mellitus Tipo 2/metabolismo , Diabetes Mellitus Tipo 2/fisiopatologia , Nefropatias Diabéticas/diagnóstico por imagem , Nefropatias Diabéticas/metabolismo , Nefropatias Diabéticas/fisiopatologia , Impedância Elétrica , Feminino , Homeostase , Humanos , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/metabolismo , Músculo Esquelético/fisiopatologia , Valor Preditivo dos Testes , Pele/metabolismo , Pele/fisiopatologia , Distribuição Tecidual
5.
Eur Radiol ; 28(10): 4254-4264, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29675659

RESUMO

OBJECTIVES: We compared the interobserver agreement for the recently introduced contrast-enhanced ultrasound (CEUS)-based algorithm CEUS-LI-RADS (Liver Imaging Reporting and Data System) versus the well-established magnetic resonance imaging (MRI)-LI-RADS for non-invasive diagnosis of hepatocellular carcinoma (HCC) in high-risk patients. METHODS: Focal liver lesions in 50 high-risk patients (mean age 66.2 ± 11.8 years; 39 male) were assessed retrospectively with CEUS and MRI. Two independent observers reviewed CEUS and MRI examinations, separately, classifying observations according to CEUS-LI-RADSv.2016 and MRI-LI-RADSv.2014. Interobserver agreement was assessed with Cohen's kappa. RESULTS: Forty-three lesions were HCCs; two were intrahepatic cholangiocarcinomas; five were benign lesions. Arterial phase hyperenhancement was perceived less frequently with CEUS than with MRI (37/50 / 38/50 lesions = 74%/78% [CEUS; observer 1/observer 2] versus 46/50 / 44/50 lesions = 92%/88% [MRI; observer 1/observer 2]). Washout appearance was observed in 34/50 / 20/50 lesions = 68%/40% with CEUS and 31/50 / 31/50 lesions = 62%/62%) with MRI. Interobserver agreement was moderate for arterial hyperenhancement (ĸ = 0.511/0.565 [CEUS/MRI]) and "washout" (ĸ = 0.490/0.582 [CEUS/MRI]), fair for CEUS-LI-RADS category (ĸ = 0.309) and substantial for MRI-LI-RADS category (ĸ = 0.609). Intermodality agreement was fair for arterial hyperenhancement (ĸ = 0.329), slight to fair for "washout" (ĸ = 0.202) and LI-RADS category (ĸ = 0.218) CONCLUSION: Interobserver agreement is substantial for MRI-LI-RADS and only fair for CEUS-LI-RADS. This is mostly because interobserver agreement in the perception of washout appearance is better in MRI than in CEUS. Further refinement of the LI-RADS algorithms and increasing education and practice may be necessary to improve the concordance between CEUS and MRI for the final LI-RADS categorization. KEY POINTS: • CEUS-LI-RADS and MRI-LIRADS enable standardized non-invasive diagnosis of HCC in high-risk patients. • With CEUS, interobserver agreement is better for arterial hyperenhancement than for "washout". • Interobserver agreement for major features is moderate for both CEUS and MRI. • Interobserver agreement for LI-RADS category is substantial for MRI, and fair for CEUS. • Interobserver-agreement for CEUS-LI-RADS will presumably improve with ongoing use of the algorithm.


Assuntos
Algoritmos , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ultrassonografia/métodos , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/patologia , Colangiocarcinoma/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Feminino , Humanos , Cirrose Hepática/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
6.
Cardiol Young ; 28(5): 661-667, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29345604

RESUMO

BACKGROUND: Optimal imaging is essential for catheter-based interventions in CHD. The three-dimensional models in volume-rendering technique currently in use are not standardised. This paper investigates the feasibility and impact of novel three-dimensional guidance with segmented and tessellated three-dimensional heart models in catheterisation of CHD. In addition, a nearly radiation-free two- to three-dimensional registration and a biplane overlay were used.Methods and resultsWe analysed 60 consecutive cases in which segmented tessellated three-dimensional heart models were merged with live fluoroscopy images and aligned using the tracheal bifurcation as a fiducial mark. The models were generated from previous MRI or CT by dedicated medical software. We chose the stereo-lithography format, as this promises advantage over volume-rendering-technique models regarding visualisation. Prospects, potential benefits, and accuracy of the two- to three-dimensional registration were rated separately by two paediatric interventionalists on a five-point Likert scale. Fluoroscopy time, radiation dose, and contrast dye consumption were evaluated. Over a 10-month study period, two- to three-dimensional image fusion was applied to 60 out of 354 cases. Of the 60 catheterisations, 73.3% were performed in the context of interventions. The accuracy of two- to three-dimensional registration was sufficient in all cases. Three-dimensional guidance was rated superior to conventional biplane imaging in all 60 cases. We registered significantly smaller amounts of used contrast dye (p<0.01), lower levels of radiation dose (p<0.02), and less fluoroscopy time (p<0.01) during interventions concerning the aortic arch compared with a control group. CONCLUSIONS: Two- to three-dimensional image fusion can be applied successfully in most catheter-based interventions of CHD. Meshes in stereo-lithography format are accurate and base for standardised and reproducible three-dimensional models.


Assuntos
Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Simulação por Computador , Diagnóstico por Imagem/métodos , Cardiopatias Congênitas/cirurgia , Imageamento Tridimensional , Cirurgia Assistida por Computador/métodos , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Fluoroscopia/métodos , Seguimentos , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Lactente , Recém-Nascido , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
7.
J Sports Sci Med ; 17(3): 392-401, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30116112

RESUMO

Delayed-onset muscle soreness (DOMS), an ultrastructural muscle injury, is one of the most common reasons for impaired muscle performance. The purpose of this study was to investigate the influence of sport compression garments on the development of exercise-induced intramuscular edema in the context of DOMS. DOMS was induced in 15 healthy participants. The participants performed a standardized eccentric exercise of the calf muscles. Magnetic resonance imaging (MRI) was performed at baseline and 60h after exercise (T2-weighted signal intensity and T2 relaxation time was evaluated in each compartment and the intramuscular edema in the medial head of the gastrocnemius muscle was segmented). After the exercise, a conventional compression garment (18-21 mmHg) was placed on one randomized calf for 60h. The level of muscle soreness was evaluated using a visual analogue pain scale. T2-weighted signal intensity, T2 relaxation time and intramuscular edema showed a significant interaction for time with increased signal intensities/intramuscular edema in the medial head of the gastrocnemius muscle at follow-up compared to baseline. No significant main effect for compression or interaction between time and limb occurred. Further, no significant differences in the soleus muscle and the lateral head of the gastrocnemius muscle were noted between limbs or over time. After exercise, there was significantly increased muscle soreness in both lower legs in resting condition and when going downstairs and a decreased range of motion in the ankle joint. No significant difference was observed between the compressed and the non-compressed calf. Our results indicate that wearing conventional compression garments after DOMS has been induced has no significant effect on the development of muscle edema, muscle soreness, range of motion and calf circumference.


Assuntos
Edema/prevenção & controle , Músculo Esquelético/lesões , Mialgia/prevenção & controle , Meias de Compressão , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Medição da Dor , Amplitude de Movimento Articular , Adulto Jovem
8.
Rheumatology (Oxford) ; 56(4): 556-560, 2017 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-28013199

RESUMO

Objective: Skin fibrosis is the predominant feature of SSc and arises from excessive extracellular matrix deposition. Glycosaminoglycans are macromolecules of the extracellular matrix, which facilitate Na + accumulation in the skin. We used 23 Na-MRI to quantify Na + in skin. We hypothesized that skin Na + might accumulate in SSc and might be a biomarker for skin fibrosis. Methods: In this observational case-control study, skin Na + was determined by 23 Na-MRI using a Na + volume coil in 12 patients with diffuse cutaneous SSc and in 21 control subjects. We assessed skin fibrosis by the modified Rodnan skin score prior to 23 Na-MRI and on follow-up 12 months later. Results: 23 Na-MRI demonstrated increased Na + in the fibrotic skin of SSc patients compared with skin from controls [mean ( s . d .): 27.2 (5.6) vs 21.4 (5.3) mmol/l, P < 0.01]. Na + content was higher in fibrotic than in non-fibrotic SSc skin [26.2 (4.8) vs 19.2 (3.4) mmol/l, P < 0.01]. Furthermore, skin Na + amount was correlated with changes in follow-up modified Rodnan skin score (R 2 = 0.68). Conclusions: 23 Na-MRI detected increased Na + in the fibrotic SSc skin; high Na + content was associated with progressive skin disease. Our findings provide the first evidence that 23 Na-MRI might be a promising tool to assess skin Na + and thereby predict progression of skin fibrosis in SSc.


Assuntos
Escleroderma Sistêmico/metabolismo , Pele/patologia , Sódio/metabolismo , Estudos de Casos e Controles , Feminino , Fibrose/metabolismo , Antebraço , Humanos , Extremidade Inferior , Imageamento por Ressonância Magnética/métodos , Masculino , Pele/metabolismo , Isótopos de Sódio
9.
Pediatr Cardiol ; 38(8): 1540-1547, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28762166

RESUMO

Computed tomography (CT)-angiography is routinely performed prior to catheter-based and surgical treatment in congenital heart disease. To date, little is known about the accuracy and advantage of different 3D-reconstructions in CT-data. Exact anatomical information is crucial. We analyzed 35 consecutive CT-angiographies of infants with congenital heart disease. All datasets are reconstructed three-dimensionally using volume rendering technique (VRT) and threshold-based segmentation (stereolithographic model, STL). Additionally, the two-dimensional maximum intensity projection (MIP) reconstructs two-dimensional data. In each dataset and resulting image, measurements of vascular diameters for four different vessels were estimated and compared to the reference standard, measured via multiplanar reformation (MPR). The resulting measurements obtained via the STL-images, MIP-images, and the VRT-images were compared with the reference standard. There was a significant difference (p < 0.05) between measurements. The mean difference was 0.0 for STL-images, -0.1 for MIP-images, and -0.3 for VRT-images. The range of the differences was -0.7 to 1.0 mm for STL-images, -0.6 to 0.5 mm for MIP-images and -1.1 to 0.7 mm for VRT-images. There was an excellent correlation between the STL-, MIP-, VRT-measurements, and the reference standard. Inter-reader reliability was excellent (p < 0.01). STL-models of cardiovascular structures are more accurate than the traditional VRT-models. Additionally, they can be standardized and are reproducible.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Imageamento Tridimensional/métodos , Criança , Feminino , Coração/diagnóstico por imagem , Humanos , Lactente , Masculino , Modelos Cardiovasculares , Reprodutibilidade dos Testes
10.
J Digit Imaging ; 30(2): 244-254, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28025731

RESUMO

Volumetric analysis of the kidney parenchyma provides additional information for the detection and monitoring of various renal diseases. Therefore the purposes of the study were to develop and evaluate a semi-automated segmentation tool and a modified ellipsoid formula for volumetric analysis of the kidney in non-contrast T2-weighted magnetic resonance (MR)-images. Three readers performed semi-automated segmentation of the total kidney volume (TKV) in axial, non-contrast-enhanced T2-weighted MR-images of 24 healthy volunteers (48 kidneys) twice. A semi-automated threshold-based segmentation tool was developed to segment the kidney parenchyma. Furthermore, the three readers measured renal dimensions (length, width, depth) and applied different formulas to calculate the TKV. Manual segmentation served as a reference volume. Volumes of the different methods were compared and time required was recorded. There was no significant difference between the semi-automatically and manually segmented TKV (p = 0.31). The difference in mean volumes was 0.3 ml (95% confidence interval (CI), -10.1 to 10.7 ml). Semi-automated segmentation was significantly faster than manual segmentation, with a mean difference = 188 s (220 vs. 408 s); p < 0.05. Volumes did not differ significantly comparing the results of different readers. Calculation of TKV with a modified ellipsoid formula (ellipsoid volume × 0.85) did not differ significantly from the reference volume; however, the mean error was three times higher (difference of mean volumes -0.1 ml; CI -31.1 to 30.9 ml; p = 0.95). Applying the modified ellipsoid formula was the fastest way to get an estimation of the renal volume (41 s). Semi-automated segmentation and volumetric analysis of the kidney in native T2-weighted MR data delivers accurate and reproducible results and was significantly faster than manual segmentation. Applying a modified ellipsoid formula quickly provides an accurate kidney volume.


Assuntos
Nefropatias/diagnóstico por imagem , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Reprodutibilidade dos Testes
11.
BMC Med Imaging ; 16(1): 39, 2016 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-27198576

RESUMO

BACKGROUND: To evaluate screening and diagnostic accuracy for the detection of osteoblastic rib lesions using an advanced post-processing package enabling in-plane rib reading in CT-images. METHODS: We retrospectively assessed the CT-data of 60 consecutive prostate cancer patients by applying dedicated software enabling in-plane rib reading. Reading the conventional multiplanar reconstructions was considered to be the reference standard. To simulate clinical practice, the reader was given 10 s to screen for sclerotic rib lesions in each patient applying both approaches. Afterwards, every rib was evaluated individually with both approaches without a time limit. Sensitivities, specificities, positive/negative predictive values and the time needed for detection were calculated depending on the lesion's size (largest diameter < 5 mm, 5-10 mm, > 10 mm). RESULTS: In 53 of 60 patients, all ribs were properly displayed in plane, in five patients ribs were partially displayed correctly, and in two patients none of the ribs were displayed correctly. During the 10-s screening approach all patients with sclerotic rib lesions were correctly identified reading the in-plane images (including the patients without a correct rib segmentation), whereas 14 of 23 patients were correctly identified reading conventional multiplanar images. Overall screening sensitivity, specificity, and positive/negative predictive values were 100/27.0/46.0/100 %, respectively, for in-plane reading and 60.9/100/100/80.4 %, respectively, for multiplanar reading. Overall diagnostic (no time limit) sensitivity, specificity, and positive/negative predictive values of in-plane reading were 97.8/92.8/74.6/99.5 %, respectively. False positive results predominantly occurred for lesions <5 mm in size. CONCLUSIONS: In-plane reading of the ribs allows reliable detection of osteoblastic lesions for screening purposes. The limited specificity results from false positives predominantly occurring for small lesions.


Assuntos
Neoplasias Ósseas/secundário , Interpretação de Imagem Assistida por Computador/métodos , Osteoblastos/patologia , Neoplasias da Próstata/diagnóstico por imagem , Costelas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Neoplasias Ósseas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Costelas/patologia , Sensibilidade e Especificidade , Software
12.
Pediatr Radiol ; 46(4): 462-72, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26739141

RESUMO

BACKGROUND: Many technical updates have been made in multi-detector CT. OBJECTIVE: To evaluate image quality and radiation dose of high-pitch second- and third-generation dual-source chest CT angiography and to assess the effects of different levels of advanced modeled iterative reconstruction (ADMIRE) in newborns and children. MATERIALS AND METHODS: Chest CT angiography (70 kVp) was performed in 42 children (age 158 ± 267 days, range 1-1,194 days). We evaluated subjective and objective image quality, and radiation dose with filtered back projection (FBP) and different strength levels of ADMIRE. For comparison were 42 matched controls examined with a second-generation 128-slice dual-source CT-scanner (80 kVp). RESULTS: ADMIRE demonstrated improved objective and subjective image quality (P < .01). Mean signal/noise, contrast/noise and subjective image quality were 11.9, 10.0 and 1.9, respectively, for the 80 kVp mode and 11.2, 10.0 and 1.9 for the 70 kVp mode. With ADMIRE, the corresponding values for the 70 kVp mode were 13.7, 12.1 and 1.4 at strength level 2 and 17.6, 15.6 and 1.2 at strength level 4. Mean CTDIvol, DLP and effective dose were significantly lower with the 70-kVp mode (0.31 mGy, 5.33 mGy*cm, 0.36 mSv) compared to the 80-kVp mode (0.46 mGy, 9.17 mGy*cm, 0.62 mSv; P < .01). CONCLUSION: The third-generation dual-source CT at 70 kVp provided good objective and subjective image quality at lower radiation exposure. ADMIRE improved objective and subjective image quality.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Exposição à Radiação/prevenção & controle , Proteção Radiológica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Radiografia Torácica/métodos , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Doses de Radiação , Exposição à Radiação/análise , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
BMC Med Inform Decis Mak ; 16: 5, 2016 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-26801764

RESUMO

BACKGROUND: In radiology, a vast amount of diverse data is generated, and unstructured reporting is standard. Hence, much useful information is trapped in free-text form, and often lost in translation and transmission. One relevant source of free-text data consists of reports covering the assessment of changes in tumor burden, which are needed for the evaluation of cancer treatment success. Any change of lesion size is a critical factor in follow-up examinations. It is difficult to retrieve specific information from unstructured reports and to compare them over time. Therefore, a prototype was implemented that demonstrates the structured representation of findings, allowing selective review in consecutive examinations and thus more efficient comparison over time. METHODS: We developed a semantic Model for Clinical Information (MCI) based on existing ontologies from the Open Biological and Biomedical Ontologies (OBO) library. MCI is used for the integrated representation of measured image findings and medical knowledge about the normal size of anatomical entities. An integrated view of the radiology findings is realized by a prototype implementation of a ReportViewer. Further, RECIST (Response Evaluation Criteria In Solid Tumors) guidelines are implemented by SPARQL queries on MCI. The evaluation is based on two data sets of German radiology reports: An oncologic data set consisting of 2584 reports on 377 lymphoma patients and a mixed data set consisting of 6007 reports on diverse medical and surgical patients. All measurement findings were automatically classified as abnormal/normal using formalized medical background knowledge, i.e., knowledge that has been encoded into an ontology. A radiologist evaluated 813 classifications as correct or incorrect. All unclassified findings were evaluated as incorrect. RESULTS: The proposed approach allows the automatic classification of findings with an accuracy of 96.4 % for oncologic reports and 92.9 % for mixed reports. The ReportViewer permits efficient comparison of measured findings from consecutive examinations. The implementation of RECIST guidelines with SPARQL enhances the quality of the selection and comparison of target lesions as well as the corresponding treatment response evaluation. CONCLUSIONS: The developed MCI enables an accurate integrated representation of reported measurements and medical knowledge. Thus, measurements can be automatically classified and integrated in different decision processes. The structured representation is suitable for improved integration of clinical findings during decision-making. The proposed ReportViewer provides a longitudinal overview of the measurements.


Assuntos
Ontologias Biológicas , Processamento de Imagem Assistida por Computador/métodos , Aplicações da Informática Médica , Modelos Teóricos , Radiologia/métodos , Humanos , Semântica
14.
J Digit Imaging ; 29(2): 183-8, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26438423

RESUMO

To investigate whether abdominopelvic hemorrhage shown on computed tomography (CT) images can be diagnosed with the same accuracy on a tablet computer as on a dedicated reading display. One hundred patients with a clinical suspicion of abdominopelvic hemorrhage that underwent biphasic CT imaging were retrospectively read by two readers on a dedicated reading display (reference standard) and on a tablet computer (iPad Air). Reading was performed in a dedicated reading room with ambient light conditions. Image evaluation included signs of an active hemorrhage (extravasation of contrast media) and different signs indicating a condition after abdominopelvic hemorrhage (hematoma, intestinal clots, vessel stump, free abdominopelvic fluid with a mean Hounsfield unit value >20, and asymmetric muscle volume indicating intramuscular hemorrhage). Sensitivity, specificity, and positive and negative predictive values (PPV/NPV) were calculated for the tablet-based reading. Active abdominopelvic hemorrhage (n = 72) was diagnosed with the tablet computer with a sensitivity of 0.96, a specificity of 0.93, a PPV of 0.97, and an NPV of 0.90. The results for the detection of the signs indicating a condition after abdominopelvic hemorrhage range from 0.83 to 1.00 in the case of sensitivity, from 0.95 to 1.00 in the case of specificity, from 0.94 to 1.00 in the case of the PPV, and from 0.96 to 1.00 in the case of the NPV. Abdominopelvic hemorrhage shown on CT images can be diagnosed on a tablet computer with a high diagnostic accuracy allowing mobile on-call diagnoses. This may be helpful because an early and reliable diagnosis at any time is crucial for an adequate treatment strategy.


Assuntos
Computadores de Mão/normas , Hemorragia/diagnóstico por imagem , Pelve/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/normas , Tomografia Computadorizada por Raios X , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Estudos Retrospectivos
15.
Kidney Int ; 87(2): 434-41, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25100048

RESUMO

We have previously reported that sodium is stored in skin and muscle. The amounts stored in hemodialysis (HD) patients are unknown. We determined whether (23)Na magnetic resonance imaging (sodium-MRI) allows assessment of tissue sodium and its removal in 24 HD patients and 27 age-matched healthy controls. We also studied 20 HD patients before and shortly after HD with a batch dialysis system with direct measurement of sodium in dialysate and ultrafiltrate. Age was associated with higher tissue sodium content in controls. This increase was paralleled by an age-dependent decrease of circulating levels of vascular endothelial growth factor-C (VEGF-C). Older (>60 years) HD patients showed increased sodium and water in skin and muscle and lower VEGF-C levels compared with age-matched controls. After HD, patients with low VEGF-C levels had significantly higher skin sodium content compared with patients with high VEGF-C levels (low VEGF-C: 2.3 ng/ml and skin sodium: 24.3 mmol/l; high VEGF-C: 4.1 ng/ml and skin sodium: 18.2 mmol/l). Thus, sodium-MRI quantitatively detects sodium stored in skin and muscle in humans and allows studying sodium storage reduction in ESRD patients. Age and VEGF-C-related local tissue-specific clearance mechanisms may determine the efficacy of tissue sodium removal with HD. Prospective trials on the relationship between tissue sodium content and hard end points could provide new insights into sodium homeostasis, and clarify whether increased sodium storage is a cardiovascular risk factor.


Assuntos
Diálise Renal , Sódio/isolamento & purificação , Sódio/metabolismo , Adulto , Fatores Etários , Idoso , Estudos de Casos e Controles , Feminino , Soluções para Hemodiálise/análise , Humanos , Falência Renal Crônica/sangue , Falência Renal Crônica/metabolismo , Falência Renal Crônica/terapia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Distribuição Tecidual , Fator C de Crescimento do Endotélio Vascular/sangue
16.
BMC Womens Health ; 15: 114, 2015 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-26631071

RESUMO

BACKGROUND: Early detection of loco-regional breast cancer recurrence improves patients' overall survival, as treatment can be initiated or active treatment can be changed. If a suspicious lymph node is diagnosed during a follow-up exam, surgical excision is often performed. The aim of this study was to evaluate the diagnostic performance of the minor invasive ultrasound-guided fine-needle aspiration cytology (FNAC) in sonomorphologically suspicious lymph nodes in breast cancer follow-up. METHODS: Between April 2010 and November 2012, we performed ultrasound-guided FNAC in 38 sonographically suspicious lymph nodes of 37 breast cancer follow-up patients. Cytological specimens were evaluated if the sample material was sufficient for diagnosis and if they contained cancer cells. Patients with negative cytology were followed up clinically and sonographically. To evaluate the diagnostic performance we calculated sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for physical examination, the different sonomorphological malignancy criteria and FNAC. RESULTS: In 36/38 (94.7 %) lymph nodes, the pathologist had enough material to establish a final diagnosis; in 2/38 (5.3 %) lymph nodes, the probe material was non-evaluable during cytology, these 2 were excluded from further statistical evaluation. Cytology revealed malignancy in 21 lymph nodes and showed no evidence for malignancy in 15 lymph nodes. There was no evidence for malignant disease in follow-up exams in the 15 cytologically benign lymph nodes with an average follow-up time of 3 years. The diagnostic performances of physical examination and FNAC were: Sensitivity 52/100 %, specificity 88/100 %, PPV 85/100 %, NPV 60/100 %, respectively. CONCLUSIONS: Our preliminary results show that FNAC is a safe and fast diagnostic approach for the evaluation of suspicious lymph nodes in the follow-up of patients with breast cancer and, thus, together with follow-up represents a feasible alternative to surgery.


Assuntos
Biópsia por Agulha Fina/métodos , Neoplasias da Mama/diagnóstico , Citodiagnóstico/métodos , Biópsia de Linfonodo Sentinela/métodos , Adulto , Mama/patologia , Neoplasias da Mama/patologia , Citodiagnóstico/normas , Feminino , Seguimentos , Humanos , Excisão de Linfonodo/métodos , Excisão de Linfonodo/estatística & dados numéricos , Linfonodos/patologia , Pessoa de Meia-Idade , Conduta Expectante/normas
18.
Pediatr Radiol ; 45(5): 651-7, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25407955

RESUMO

BACKGROUND: Cardiac MRI is an accurate and reproducible technique for the assessment of left ventricular volumes and function. The accuracy of automated segmentation and the effects of manual adjustments have not been determined in children. OBJECTIVE: To evaluate automated segmentation and the effects of manual adjustments for left ventricular parameter quantification in pediatric cardiac MR images. MATERIALS AND METHODS: Left ventricular parameters were evaluated in 45 children with suspected myocarditis (age 13.4 ± 3.5 years, range 4-17 years) who underwent cardiac MRI. Dedicated software was used to automatically segment and adjust the parameters. Results of end-diastolic volume, end-systolic volume, stroke volume, myocardial mass, and ejection fraction were documented before and after apex/base adjustment and after apex/base/myocardial contour adjustment. RESULTS: The software successfully detected the left ventricle in 42 of 45 (93.3%) children; failures occurred in the smallest and youngest children. Of those 42 children, automatically segmented end-diastolic volume (EDV) was 151 ± 47 ml, and after apex/base adjustment it was 146 ± 45 ml, after apex/base/myocardial contour adjustment 146 ± 45 ml. The corresponding results for end-systolic volume (ESV) were 66 ± 32 ml, 63 ± 29 ml and 64 ± 28 ml; for stroke volume (SV) they were 85 ± 25 ml, 83 ± 23 ml and 83 ± 23 ml; for ejection fracture (EF) they were 57 ± 10%, 58 ± 9% and 58 ± 9%, and for myocardial mass (MM) they were 104 ± 31 g, 95 ± 31 g and 94 ± 30 g. Statistically significant differences were found when comparing the EDV/ESV/MM results, the EF results after apex/base adjustment and after apex/base/myocardial contour adjustment and the SV results (except for comparing the SVs after apex/base adjustment and after apex/base/myocardial contour adjustment). CONCLUSION: Automated segmentation for the evaluation of left ventricular parameters in pediatric MR images proved to be feasible. Automated segmentation + apex/base adjustment provided clinically acceptable parameters for the majority of cases.


Assuntos
Imageamento por Ressonância Magnética , Miocardite/patologia , Disfunção Ventricular Esquerda/patologia , Adolescente , Criança , Pré-Escolar , Feminino , Ventrículos do Coração/patologia , Humanos , Masculino , Miocardite/complicações , Tamanho do Órgão , Reprodutibilidade dos Testes , Volume Sistólico , Disfunção Ventricular Esquerda/complicações
20.
BMC Anesthesiol ; 14: 94, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25364301

RESUMO

BACKGROUND: To assess the value of a score-based system which allows standardized evaluation of pulmonary edema on bedside chest radiographs (CXRs) under routine clinical conditions. METHODS: Seven experienced readers assessed bedside CXRs of ten patients with an extravascular lung water (EVLW)-value of ≤ 8 mL/kg (range: 4-8 mL/kg; indicates no pulmonary edema) and a series of ten patients with an EVLW-value of ≥ 15 mL/kg (range: 15-21 mL/kg; = indicates a pulmonary edema) with and without customized software which would permit a standardized assessment of the various indications of pulmonary edema. The software provides a score that identifies patients with and without pulmonary edema. EVLW-values were measured instantly after bedside CXR imaging using a pulse contour cardiac output (PiCCO) system and served as a reference standard. The patients were non-traumatic and not treated with diuretics or dobutamine during bedside CXR imaging and the PiCCO measurements. Mean sensitivity, specificity, positive and negative predictive value, the percentage of overall agreement and the free-marginal multirater kappa value was calculated for both the standard and the standardized score-based approach. The net reclassification index was calculated for each reader as well as for all readers. RESULTS: Evaluation of bedside CXRs by means of the score-based approach took longer (23 ± 12 seconds versus 7 ± 3 seconds without the use of the software) but improved radiologists' sensitivity (from 57 to 77%), specificity (from 90 to 100%) and the free-marginal multirater kappa value (from 0.34 to 0.68). The positive predictive value was raised from 85 to 100% and the negative predictive value from 68 to 81%. A net reclassification index of 0.3 (all readers) demonstrates an improvement in prediction performance gained by the score-based approach. The percentage of overall agreement was 67% with the standard approach and 84% with the software-based approach. CONCLUSIONS: The diagnostic accuracy of bedside CXRs to discriminate patients with elevated EVLW-values from those with a normal value can be improved with the use of a standardized score-based approach. The investigated system is freely available as a web-based application (accessible via: http://www.radiologie.uk-erlangen.de/aerzte-und-zuweiser/edema).


Assuntos
Edema Pulmonar/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Débito Cardíaco/fisiologia , Água Extravascular Pulmonar/metabolismo , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Sistemas Automatizados de Assistência Junto ao Leito , Radiografia Torácica , Padrões de Referência , Reprodutibilidade dos Testes , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA