Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 27(4): 1377-1385, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27510627

RESUMO

OBJECTIVES: To evaluate the use of dual-energy CT imaging of the lung perfused blood volume (PBV) for the detection of pulmonary fat embolism (PFE). METHODS: Dual-energy CT was performed in 24 rabbits before and 1 hour, 1 day, 4 days and 7 days after artificial induction of PFE via the right ear vein. CT pulmonary angiography (CTPA) and lung PBV images were evaluated by two radiologists, who recorded the presence, number, and location of PFE on a per-lobe basis. Sensitivity, specificity, and accuracy of CTPA and lung PBV for detecting PFE were calculated using histopathological evaluation as the reference standard. RESULTS: A total of 144 lung lobes in 24 rabbits were evaluated and 70 fat emboli were detected on histopathological analysis. The overall sensitivity, specificity and accuracy were 25.4 %, 98.6 %, and 62.5 % for CTPA, and 82.6 %, 76.0 %, and 79.2 % for lung PBV. Higher sensitivity (p < 0.001) and accuracy (p < 0.01), but lower specificity (p < 0.001), were found for lung PBV compared with CTPA. Dual-energy CT can detect PFE earlier than CTPA (all p < 0.01). CONCLUSION: Dual-energy CT provided higher sensitivity and accuracy in the detection of PFE as well as earlier detection compared with conventional CTPA in this animal model study. KEY POINTS: • Fat embolism occurs commonly in patients with traumatic bone injury. • Dual-energy CT improves diagnostic performance for pulmonary fat embolism detection. • Dual-energy CT can detect pulmonary fat embolism earlier than CTPA.


Assuntos
Embolia Gordurosa/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Angiografia/métodos , Animais , Modelos Animais de Doenças , Humanos , Artéria Pulmonar/diagnóstico por imagem , Coelhos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
World J Clin Cases ; 9(25): 7484-7489, 2021 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-34616816

RESUMO

BACKGROUND: Octreotide is widely used for the treatment of acromegaly, neuroendocrine tumors, and secretory diarrhea. However, long-term octreotide treatment can increase the incidence of gallstones. Vicarious contrast medium excretion (VCME) through the hepatobiliary system is well known. However, few studies have reported octreotide-induced acute gallstones following VCME. CASE SUMMARY: A 69-year-old man presented with left lower back pain and hematuria caused by a fall. The patient had a history of polycystic kidney disease. VCME occurred following renal artery embolization for a ruptured polycystic kidney. After 5 d of treatment with octreotide, the patient developed acute gallstones and intrahepatic cholestasis which further induced pancreatitis and cholangitis. He was discharged after hemodialysis, antibiotics, and supportive treatments. CONCLUSION: For patients with a high-risk of VCME, octreotide should be cautiously administered and carefully monitored.

3.
Exp Ther Med ; 20(2): 1353-1358, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32742370

RESUMO

The present study aimed to assess the usefulness of Dyna CT during transarterial uterine artery embolization (UAE) of fibroids. A total of 65 patients with symptomatic submucosal and intramural fibroids scheduled for transarterial UAE at the First People's Hospital of Changhou between May 2016 and September 2018 were included. Dyna CT and routine digital subtraction angiography (DSA) were performed in all patients during angiographic embolization of the bilateral internal iliac arteries. The visualization qualities of uterine artery origin and fibroids, as imaged by Dyna CT, were compared with DSA anterior-posterior images. Dyna CT provided excellent 3-dimensional visualization of vascular structures of the bilateral internal iliac arteries and uterine artery origin. Dyna CT was primarily useful in patients with overlapped uterine arteries or complex vascular anatomies on DSA anterior-posterior images (Dyna CT 100% vs. DSA anterior-posterior 69.2%, P=0.03). However, stained fibroids were identified in 57/65 cases (87.7%) by Dyna CT, and in all of the cases (100%) by DSA anterior-posterior imaging (P=0.03). Dyna CT is not suitable for procedural evaluation when used alone for transarterial UAE of fibroids. However, Dyna CT is an excellent supplement to DSA anterior-posterior imaging, as it provides additional information to aid in treatment planning.

4.
Eur J Radiol ; 85(2): 498-506, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26781157

RESUMO

PURPOSE: To compare diagnostic accuracy between dual-energy CT lung perfused blood volume (Lung PBV) imaging and single photon emission computed tomography (SPECT) in detecting chronic thromboembolic pulmonary hypertension (CTEPH) with histopathological results as reference standard in a canine model. MATERIALS AND METHODS: Eighteen CTEPH canines were included into this experimental study. All procedures including paracentesis, embolization, scanning, pressure measurement and feeding medicine were repeated each two weeks, until systolic/diastolic pressure in canines was ≥ 30/15 mm Hg or mean pulmonary artery pressure ≥ 20 mm Hg, and then sacrificed for histopathology examination. Two radiologists (readers 1 and 2) and two nuclear radiologists (readers 3 and 4) analyzed images of conventional CT pulmonary angiography in dual-energy CT mode, Lung PBV imaging and SPECT, respectively. The presence, numbers, and locations of pulmonary emboli (PE) were recorded on a per-lobe basis. Pathological examination was served as reference standard. Sensitivity, specificity and accuracy of Lung PBV and SPECT were calculated. Kappa statistics were used to quantify inter-reader agreement. RESULTS: With histopathological results as reference standard, the sensitivities of 72.2%, 78.8%, 81.2%, specificities of 75.9%, 87.5%, 84.8%, accuracies of 73.8%, 83.1%, 83.1%, for readers 1, 2 and both with Lung PBV, respectively. Readers 3, 4 and both had sensitivities of 14.3%, 25.7%, 33.3%, specificities of 90.0%, 86.7%, 93.3%, accuracies of 49.2%, 53.8%, 60.0% with SPECT for detecting CTEPH. Inter-reader agreements were good for dual-energy CT (kappa=0.662) and SPECT (k=0.706) for detecting CTEPH. CONCLUSION: Dual-energy CT had a higher accuracy to detect CTEPH than SPECT in this canine model study.


Assuntos
Hipertensão Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Animais , Volume Sanguíneo , Doença Crônica , Modelos Animais de Doenças , Cães , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sístole
5.
Eur J Radiol ; 82(12): 2270-8, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23891532

RESUMO

PURPOSE: To evaluate the performance of dual-energy CT (DECT) based vascular iodine analysis for the detection of acute peripheral pulmonary thrombus (PE) in a canine model with histopathological findings as the reference standard. MATERIALS AND METHODS: The study protocol was approved by our institutional animal committee. Thrombi (n = 12) or saline (n = 4) were intravenously injected via right femoral vein in sixteen dogs, respectively. CT pulmonary angiography (CTPA) in DECT mode was performed and conventional CTPA images and DECT based vascular iodine studies using Lung Vessels application were reconstructed. Two radiologists visually evaluated the number and location of PEs using conventional CTPA and DECT series on a per-animal and a per-clot basis. Detailed histopathological examination of lung specimens and catheter angiography served as reference standard. Sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of DECT and CTPA were calculated on a segmental and subsegmental or more distal pulmonary artery basis. Weighted κ values were computed to evaluate inter-modality and inter-reader agreement. RESULTS: Thirteen dogs were enrolled for final image analysis (experimental group = 9, control group = 4). Histopathological results revealed 237 emboli in 45 lung lobes in 9 experimental dogs, 11 emboli in segmental pulmonary arteries, 49 in subsegmental pulmonary arteries, 177 in fifth-order or more distal pulmonary arteries. Overall sensitivity, specificity, accuracy, PPV, and NPV for CTPA plus DECT were 93.1%, 76.9%, 87.8%, 89.4%, and 84.2% for the detection of pulmonary emboli. With CTPA versus DECT, sensitivities, specificities, accuracies, PPVs, and NPVs are all 100% for the detection of pulmonary emboli on a segmental pulmonary artery basis, 88.9%, 100%, 96.0%, 100%, and 94.1% for CTPA and 90.4%, 93.0%, 92.0%, 88.7%, and 94.1% for DECT on a subsegmental pulmonary artery basis; 23.8%, 96.4%, 50.4%, 93.5%, and 36.7% for CTPA and 95.9%, 75.5%, 88.2%, 86.5%, and 91.9% on a sub-subsegmental and more distal pulmonary artery basis, respectively. Good inter-modality (κ = 0.65, P<0.001) and inter-reader (κ = 0.70, P<0.001) agreement were observed. CONCLUSION: With histopathological findings as the reference standard, DECT based vascular iodine analysis improves the sensitivity for detecting peripheral PE compared with CTPA, albeit at the price of decreased specificity and PPV.


Assuntos
Iohexol/análogos & derivados , Embolia Pulmonar/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Meios de Contraste/administração & dosagem , Cães , Injeções Intravenosas , Iohexol/administração & dosagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA