Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39109463

RESUMO

BACKGROUND: In 2019, the US Food and Drug Administration (FDA) approved transcatheter aortic valve replacement (TAVR) for low-risk patients with symptomatic severe tricuspid aortic stenosis. However, bicuspid aortic valve (BAV) patients were included only in single-arm registries of pivotal low-risk TAVR trials, resulting in limited data for this subgroup. METHODS: The LRT (Low Risk TAVR) trial was an investigator-initiated, prospective, multicenter study and the first FDA-approved investigational device exemption trial to evaluate the feasibility of TAVR with balloon-expandable or self-expanding valves in low-risk patients with symptomatic severe BAV stenosis. This analysis reports 2-year follow-up, assessing the primary outcome of all-cause mortality and evaluating clinical outcomes. RESULTS: From 2016 to 2019, a total of 72 low-risk patients diagnosed with symptomatic, severe BAV stenosis underwent TAVR across six centers. Six patients were lost to follow-up. At 2-year follow-up, mortality was 1.5% (1 of 66 patients). Among the remaining 65 patients, four experienced nondisabling strokes (6.2%), while 2 (3.1%) developed infective endocarditis. No new permanent pacemakers were required beyond the 30-day follow-up, and no patients, including those with endocarditis, needed aortic valve re-intervention. At the 2-year echocardiography follow-up (n = 65), 27.8% of BAV patients showed mild aortic regurgitation, with none exhibiting moderate or severe regurgitation. The mean aortic gradient was 12.1 ± 4.1 mmHg, and the mean valve area was 1.7 ± 0.5 cm². CONCLUSION: The 2-year follow-up confirms commendable clinical outcomes of TAVR in patients with bicuspid aortic stenosis, establishing its evident safety.

2.
Int J Cardiol ; 395: 131431, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37832606

RESUMO

BACKGROUND: Recent randomized studies have broadened the indication of transcatheter aortic valve replacement (TAVR) to also include low-surgical-risk patients. However, the data on self-expanding (SE) and balloon-expandable (BE) valves in low-risk patients remain sparse. METHODS: The current study is a post hoc analysis of combined data from both LRT 1.0 and 2.0 trials comparing BE and SE transcatheter heart valves. RESULTS: A total of 294 patients received a BE valve, and 102 patients received an SE valve. The 30-day clinical outcomes were similar across both groups except for stroke (4.9% vs. 0.7%, p = 0.014) and permanent pacemaker implantation (17.8% vs. 5.8%, p < 0.001), which were higher in the SE cohort than the BE cohort. No difference was observed in terms of paravalvular leak (≥moderate) between the groups (0% vs. 1.5%, p = 0.577). SE patients had higher aortic valve area (1.92 ± 0.43 mm2 vs. 1.69 ± 0.45 mm2, p < 0.001) and lower mean gradient (8.93 ± 3.53 mmHg vs. 13.41 ± 4.73 mmHg, p < 0.001) than BE patients. In addition, the rate of subclinical leaflet thrombosis was significantly lower in SE patients (5.6% vs. 13.8%, p = 0.038). CONCLUSION: In this non-randomized study assessing SE and BE valves in low-risk TAVR patients, SE valves are associated with better hemodynamics and lesser leaflet thrombosis, with increased rates of stroke and permanent pacemaker implantation at 30 days; however, this could be due to certain patient-dependent factors not fully evaluated in this study. The long-term implications of these outcomes on structural valve durability remain to be further investigated. CLINICAL TRIAL REGISTRY: LRT 1.0: NCT02628899 LRT 2.0: NCT03557242.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Acidente Vascular Cerebral/etiologia , Trombose/etiologia , Resultado do Tratamento , Desenho de Prótese , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA