Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 380(26): 2541-2550, 2019 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-30946551

RESUMO

BACKGROUND: During the introduction of transcatheter aortic-valve replacement (TAVR) in the United States, requirements regarding procedural volume were mandated by the Centers for Medicare and Medicaid Services as a condition of reimbursement. A better understanding of the relationship between hospital volume of TAVR procedures and patient outcomes could inform policy decisions. METHODS: We analyzed data from the Transcatheter Valve Therapy Registry regarding procedural volumes and outcomes from 2015 through 2017. The primary analyses examined the association between hospital procedural volume as a continuous variable and risk-adjusted mortality at 30 days after transfemoral TAVR. Secondary analysis included risk-adjusted mortality according to quartile of hospital procedural volume. A sensitivity analysis was performed after exclusion of the first 12 months of transfemoral TAVR procedures at each hospital. RESULTS: Of 113,662 TAVR procedures performed at 555 hospitals by 2960 operators, 96,256 (84.7%) involved a transfemoral approach. There was a significant inverse association between annualized volume of transfemoral TAVR procedures and mortality. Adjusted 30-day mortality was higher and more variable at hospitals in the lowest-volume quartile (3.19%; 95% confidence interval [CI], 2.78 to 3.67) than at hospitals in the highest-volume quartile (2.66%; 95% CI, 2.48 to 2.85) (odds ratio, 1.21; P = 0.02). The difference in adjusted mortality between a mean annualized volume of 27 procedures in the lowest-volume quartile and 143 procedures in the highest-volume quartile was a relative reduction of 19.45% (95% CI, 8.63 to 30.26). After the exclusion of the first 12 months of TAVR procedures at each hospital, 30-day mortality remained higher in the lowest-volume quartile than in the highest-volume quartile (3.10% vs. 2.61%; odds ratio, 1.19; 95% CI, 1.01 to 1.40). CONCLUSIONS: An inverse volume-mortality association was observed for transfemoral TAVR procedures from 2015 through 2017. Mortality at 30 days was higher and more variable at hospitals with a low procedural volume than at hospitals with a high procedural volume. (Funded by the American College of Cardiology Foundation National Cardiovascular Data Registry and the Society of Thoracic Surgeons.).


Assuntos
Estenose da Valva Aórtica/cirurgia , Hospitais com Alto Volume de Atendimentos/estatística & dados numéricos , Hospitais com Baixo Volume de Atendimentos/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Centers for Medicare and Medicaid Services, U.S. , Feminino , Mortalidade Hospitalar , Humanos , Reembolso de Seguro de Saúde/normas , Masculino , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Resultado do Tratamento , Estados Unidos/epidemiologia
2.
Echocardiography ; 37(5): 738-757, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32362021

RESUMO

Evaluating the hemodynamic performance of aortic valve prostheses has relied primarily on echocardiography. This involves calculating the trans-prosthetic valve mean gradient (MG) and aortic valve area (AVA), and assessing for valvular and paravalvular regurgitation in a fashion similar to the native aortic valve. In conjunction with other echocardiographic and nonechocardiographic parameters, MG and AVA are used to distinguish between prosthesis stenosis, prosthesis patient mismatch, pressure recovery, increased flow, and measurement errors. This review will discuss the principles and limitations of echocardiographic evaluation of aortic valve prosthesis following surgical, and transcatheter aortic valve replacement and in comparison to invasive hemodynamics through illustrative clinical cases.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Hemodinâmica , Humanos , Desenho de Prótese , Índice de Gravidade de Doença , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 93(7): 1228-1235, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-30393942

RESUMO

OBJECTIVE: To evaluate contrast media (CM) volume (CMV) saved using the DyeVert™ Plus Contrast Reduction System (DyeVert Plus System, Osprey Medical) in patients undergoing diagnostic coronary angiogram (CAG) and/or percutaneous coronary interventional (PCI) procedures performed with manual injections. BACKGROUND: Current guidelines advocate for monitoring and minimization of the total volume of CM in chronic kidney disease (CKD) patients undergoing invasive cardiac procedures. The DyeVert Plus System is an FDA cleared device designed to reduce CMV delivered during angiography and permit real-time CMV monitoring. METHODS: We performed a multicenter, single-arm, observational study. Eligible subjects were ≥ 18 years old with baseline estimated glomerular filtration rate (eGFR) 20-60 mL/min/1.73 m2 . The primary endpoint was % CMV saved over the total procedure. A secondary objective was to evaluate adverse events (AEs) related to DyeVert Plus System or to CM use. RESULTS: A total of 114 subjects were enrolled at eight centers. Mean age was 72 ± 9 years, 72% were male, and mean body mass index was 29 ± 5. Baseline eGFR was 43 ± 11 mL/min/1.73 m2 . CAG-only was performed in 65% of cases. One hundred and five subjects were evaluable for the primary endpoint. Mean CMV attempted was 112 ± 85 mL (range 22-681) and mean CMV delivered was 67 ± 51 mL (range 12-403), resulting in an overall CMV savings of 40.1 ± 8.8% (95% CI 38.4, 41.8; P < 0.0001) per procedure. Image quality was maintained in all but one case where the system was turned off for one injection. No DyeVert Plus System-related AEs were reported. Acute kidney injury (AKI; defined as serum creatinine rise of >0.3 mg/dL from baseline) was reported in 11 cases with seven occurring in subjects with baseline eGFR < 30 and three AKI events were attributed to CM. AKI rates increased as CMV/eGFR ratios increased. CONCLUSIONS: These data suggest DyeVert Plus System use in CKD patients undergoing CAG and/or PCI results in clinically meaningful CMV savings while maintaining image quality.


Assuntos
Injúria Renal Aguda/prevenção & controle , Meios de Contraste/administração & dosagem , Angiografia Coronária/instrumentação , Doença da Artéria Coronariana/diagnóstico por imagem , Taxa de Filtração Glomerular , Rim/efeitos dos fármacos , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/diagnóstico por imagem , Injúria Renal Aguda/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/efeitos adversos , Angiografia Coronária/efeitos adversos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/terapia , Desenho de Equipamento , Feminino , Humanos , Rim/fisiopatologia , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Proteção , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/fisiopatologia , Fatores de Risco , Resultado do Tratamento , Estados Unidos
4.
J Interv Cardiol ; 30(4): 291-300, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28543770

RESUMO

OBJECTIVES: We sought to evaluate the patterns of use and outcomes associated with eptifibatide and abciximab administration among dialysis patients who underwent percutaneous coronary intervention (PCI). BACKGROUND: Contraindicated medications are frequently administered to dialysis patients undergoing PCI often resulting in adverse outcomes. Eptifibatide is a glycoprotein IIb/IIIa inhibitor that is often used during PCI and is contraindicated in dialysis. METHODS: We included dialysis patients who underwent PCI from January 2010 to September 2015 at 47 hospitals in Michigan. We compared outcomes between patients who received eptifibatide compared with abciximab. Both groups required concurrent treatment with unfractionated heparin only. In-hospital outcomes included repeat PCI, bleeding, major bleeding, need for transfusion, and death. Optimal full matching was used to adjust for non-random drug administration. RESULTS: Of 177 963 patients who underwent PCI, 4303 (2.4%) were on dialysis. Among those, 384 (8.9%) received eptifibatide and 100 (2.3%) received abciximab. Prior to matching, patients who received eptifibatide had higher pre-procedural hemoglobin levels (11.3 g/dL vs. 10.7 g/dL; P < 0.001) and less frequently had a history of myocardial infarction (36.5% vs. 52.0%; P = 0.005). After matching, there were no significant differences in in-hospital outcomes between eptifibatide and abciximab including transfusion (aOR: 1.15; 95%CI: 0.55-2.40; P = 0.70), bleeding (1.47; 0.64-3.40; P = 0.36), major bleeding (4.68; 0.42-52.3; P = 0.21), repeat PCI (0.38; 0.03-4.23; P = 0.43), and death (1.53; 0.2-9.05; P = 0.64). CONCLUSIONS: Despite being contraindicated in dialysis, eptifibatide was used approximately 3.5 times more frequently than abciximab among dialysis patients undergoing PCI but was associated with similar in-hospital outcomes.


Assuntos
Anticorpos Monoclonais/uso terapêutico , Fragmentos Fab das Imunoglobulinas/uso terapêutico , Peptídeos/uso terapêutico , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária/uso terapêutico , Complicações Pós-Operatórias/epidemiologia , Diálise Renal , Abciximab , Idoso , Planos de Seguro Blue Cross Blue Shield , Contraindicações de Medicamentos , Eptifibatida , Feminino , Heparina/uso terapêutico , Humanos , Masculino , Michigan , Pessoa de Meia-Idade , Infarto do Miocárdio/terapia , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/antagonistas & inibidores , Estudos Retrospectivos , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 88(2): 285-6, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27530193

RESUMO

Bleeding and vascular complications are major causes of morbidity and mortality after transfemoral TAVR. Compared with standard approaches to hemostasis, the catheter balloon occlusion technique CBOT) resulted in significant reduction in major bleeding and vascular complications (18.6% vs. 5.5%, P = 0.042). Femoral crossover could not be achieved in 3.6%, and CBOT led to vessel dissection in 7.2%, major or life-threatening bleeding in 5.5%, need for transfusion > 2 units in 10.9%, and minor bleeding or hematoma in 21.8% of patients.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Cateterismo Cardíaco , Artéria Femoral/cirurgia , Próteses Valvulares Cardíacas , Humanos , Substituição da Valva Aórtica Transcateter , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 88(2): 301-6, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26481729

RESUMO

Dehiscence of a surgical mitral annuloplasty ring for repair of functional mitral regurgitation (MR) is an infrequently reported complication that often manifests as recurrent MR and heart failure. Re-do mitral valve surgery to correct ring dehiscence may not be feasible for patients at high risk of operative mortality or serious morbidity. We report two cases of mitral annular ring dehiscence and severe mitral regurgitation in patients at prohibitive risk for re-do mitral valve surgery who were successfully treated with MitraClip. © 2015 Wiley Periodicals, Inc.


Assuntos
Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral/instrumentação , Insuficiência da Valva Mitral/cirurgia , Falha de Prótese , Idoso de 80 Anos ou mais , Angiografia , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Feminino , Insuficiência Cardíaca/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Anuloplastia da Valva Mitral/efeitos adversos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Desenho de Prótese , Recidiva , Retratamento , Índice de Gravidade de Doença , Resultado do Tratamento
8.
Echocardiography ; 32(2): 372-82, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25138664

RESUMO

In patients with aortic stenosis (AS) and eccentric transaortic flow, greater pressure loss occurs as the jet collides with the aortic wall together with delayed and diminished pressure recovery. This leads to the elevated transaortic valve pressure gradients noted on both Doppler and cardiac catheterization. Such situations may present a diagnostic dilemma where traditional measures of stenosis severity indicate severe AS, while imaging modalities of the aortic valve geometric aortic valve area (GOA) suggest less than severe stenosis. In this study, we present a series of cases exemplifying this clinical dilemma and demonstrate how color M-mode, 2D and 3D transthoracic (TTE) and transesophageal (TEE) echocardiography, cardiac computed tomography angiography (CTA), and magnetic resonance imaging (MRI), may be used to resolve such discrepancies.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Pressão Sanguínea/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Ecocardiografia Doppler , Feminino , Humanos , Pessoa de Meia-Idade , Índice de Gravidade de Doença , Adulto Jovem
9.
JACC Cardiovasc Interv ; 17(5): 635-644, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38244000

RESUMO

BACKGROUND: Transcatheter closure of transcatheter heart valve (THV)-related paravalvular leak (PVL) is associated with a high failure rate with available devices due to the complex interaction of THV and aortic/mitral annulus. OBJECTIVES: This study reports on novel transcatheter techniques to treat PVL after THV. METHODS: The authors describe consecutive patients who underwent PVL closure after transcatheter aortic valve replacement (TAVR) or transcatheter mitral valve replacement (TMVR). A covered self-expanding stent (Viabahn) was deployed in the defect to create a seal between the THV and annulus. A vascular plug (Amplatzer Vascular Plug 2 [AVP2] or AVP4) was then deployed inside the covered stent to obliterate PVL. RESULTS: Eight patients with THV-related PVL were treated using this method (aortic [3 SAPIEN, 1 Evolut], mitral [2 SAPIEN-in-MAC (mitral annular calcification), 2 M3 TMVR). Various combinations of stents and plugs were used (5 mm × 2.5 cm Viabahn + 6 mm AVP4 [n = 2], 8 mm × 2.5 cm Viabahn + 10 mm AVP2 [n = 5], and 10 mm × 5.0 cm Viabahn + 12 mm AVP2 [n = 1]). All had technical success with immediate elimination of target PVL, without in-hospital complications. None had signs of postprocedure hemolysis. All patients were discharged alive (median 3.5 days [Q1-Q3: 1.0-4.8 days]). No residual PVL was seen at discharge, except for 1 patient with mild regurgitation due to another untreated PVL location. One patient died before 30 days due to complication of valve-in-MAC TMVR. In remaining patients, none had recurrence of PVL at 30 days. Symptoms decreased to NYHA functional class I/II in 6 patients. NYHA functional class III symptoms remained in 1 patient with mitral regurgitation awaiting subsequent valve replacement procedure. CONCLUSIONS: The technique of sequential deployment of a covered stent and vascular plug may effectively treat THV-related PVL.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Próteses Valvulares Cardíacas/efeitos adversos , Falha de Prótese , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Stents , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia
10.
Am J Cardiol ; 220: 84-91, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38604492

RESUMO

Development of functional tricuspid regurgitation (TR) because of chronic mitral disease and subsequent heart failure is common. However, the effect of TR on clinical outcomes after transcatheter mitral valve replacement (TMVR) remains unclear. We aimed to evaluate the impact of baseline TR on outcomes after TMVR. This was a single-center, retrospective analysis of patients who received valve-in-valve or valve-in-ring TMVR between 2012 and 2022. Patients were categorized into none/mild TR and moderate/severe TR based on baseline echocardiography. The primary outcome was 3 years all-cause death and the secondary outcomes were in-hospital events. Of the 135 patients who underwent TMVR, 64 (47%) exhibited none/mild TR at baseline, whereas 71 (53%) demonstrated moderate/severe TR. There were no significant differences in in-hospital events between the groups. At 3 years, the moderate/severe TR group exhibited a significantly increased risk of all-cause death (adjusted hazard ratio 3.37, 95% confidence interval 1.35 to 8.41, p = 0.009). When patients with baseline moderate/severe TR were stratified by echocardiography at 30 days into improved (36%) and nonimproved (64%) TR groups, although limited by small sample size, there was no significant difference in 3-year all-cause mortality (p = 0.48). In conclusion, this study investigating the impact of baseline TR on clinical outcomes revealed that moderate/severe TR is prevalent in those who underwent TMVR and is an independent predictor of 3-year all-cause mortality. Earlier mitral valve intervention before the development of significant TR may play a pivotal role in improving outcomes after TMVR.


Assuntos
Ecocardiografia , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Insuficiência da Valva Tricúspide , Humanos , Masculino , Insuficiência da Valva Tricúspide/cirurgia , Feminino , Estudos Retrospectivos , Idoso , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Cateterismo Cardíaco/métodos , Índice de Gravidade de Doença , Resultado do Tratamento , Causas de Morte/tendências , Complicações Pós-Operatórias/epidemiologia , Idoso de 80 Anos ou mais , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem
11.
J Am Coll Cardiol ; 83(14): 1257-1272, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38471643

RESUMO

BACKGROUND: Left ventricular outflow tract (LVOT) obstruction is a source of morbidity in hypertrophic cardiomyopathy (HCM) and a life-threatening complication of transcatheter mitral valve replacement (TMVR) and transcatheter aortic valve replacement (TAVR). Available surgical and transcatheter approaches are limited by high surgical risk, unsuitable septal perforators, and heart block requiring permanent pacemakers. OBJECTIVES: The authors report the initial experience of a novel transcatheter electrosurgical procedure developed to mimic surgical myotomy. METHODS: We used septal scoring along midline endocardium (SESAME) to treat patients, on a compassionate basis, with symptomatic LVOT obstruction or to create space to facilitate TMVR or TAVR. RESULTS: In this single-center retrospective study between 2021 and 2023, 76 patients underwent SESAME. In total, 11 (14%) had classic HCM, and the remainder underwent SESAME to facilitate TMVR or TAVR. All had technically successful SESAME myocardial laceration. Measures to predict post-TMVR LVOT significantly improved (neo-LVOT 42 mm2 [Q1-Q3: 7-117 mm2] to 170 mm2 [Q1-Q3: 95-265 mm2]; P < 0.001; skirt-neo-LVOT 169 mm2 [Q1-Q3: 153-193 mm2] to 214 mm2 [Q1-Q3: 180-262 mm2]; P < 0.001). Among patients with HCM, SESAME significantly decreased invasive LVOT gradients (resting: 54 mm Hg [Q1-Q3: 40-70 mm Hg] to 29 mm Hg [Q1-Q3: 12-36 mm Hg]; P = 0.023; provoked 146 mm Hg [Q1-Q3: 100-180 mm Hg] to 85 mm Hg [Q1-Q3: 40-120 mm Hg]; P = 0.076). A total of 74 (97.4%) survived the procedure. Five experienced 3 of 76 (3.9%) iatrogenic ventricular septal defects that did not require repair and 3 of 76 (3.9%) ventricular free wall perforations. Neither occurred in patients treated for HCM. Permanent pacemakers were required in 4 of 76 (5.3%), including 2 after concomitant TAVR. Lacerations were stable and did not propagate after SESAME (remaining septum: 5.9 ± 3.3 mm to 6.1 ± 3.2 mm; P = 0.8). CONCLUSIONS: With further experience, SESAME may benefit patients requiring septal reduction therapy for obstructive hypertrophic cardiomyopathy as well as those with LVOT obstruction after heart valve replacement, and/or can help facilitate transcatheter valve implantation.


Assuntos
Cardiomiopatia Hipertrófica , Implante de Prótese de Valva Cardíaca , Miotomia , Obstrução da Via de Saída Ventricular Esquerda , Obstrução do Fluxo Ventricular Externo , Humanos , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos , Cateterismo Cardíaco/métodos , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Resultado do Tratamento , Cardiomiopatia Hipertrófica/complicações , Miotomia/efeitos adversos
13.
Circ Cardiovasc Interv ; 16(10): e013243, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37732604

RESUMO

BACKGROUND: Postinfarction ventricular septal defect (VSD) is a catastrophic complication of myocardial infarction. Surgical repair still has poor outcomes. This report describes clinical outcomes after a novel hybrid transcatheter/surgical repair in patients with apical VSD. METHODS: Seven patients with postmyocardial infarction apical VSD underwent hybrid transcatheter repair via subxiphoid surgical access. A transcatheter occluder (Amplatzer Septal Occluder) with a trailing premounted suture was deployed through the right ventricular wall and through the ventricular septum into the left ventricular apex. The trailing suture was used to connect an anchor external to the right ventricular wall. Tension on the suture then collapses the right ventricular free wall against the septum and left ventricular occluder, thereby obliterating the VSD. Outcomes were compared with 9 patients who underwent surgical repair using either patch or primary suture closure. RESULTS: All patients had significant left-to-right shunt (Qp:Qs 2.5:1; interquartile range [IQR, 2.1-2.6] hybrid repair versus 2.0:1 [IQR, 2.0-2.5] surgical repair), and elevated right ventricular systolic pressure (62 [IQR, 46-71] versus 49 [IQR, 43-54] mm Hg, respectively). All had severely depressed stroke volume index (22 versus 21 mL/m2) with ≈45% in each group requiring mechanical support preprocedurally. The procedure was done 15 (IQR, 10-50) versus 24 (IQR, 10-134) days postmyocardial infarction, respectively. Both groups of patients underwent repair with technical success and without intraprocedural death. One patient in the hybrid group and 4 in the surgical group developed multiorgan failure. The hybrid group had a higher survival at discharge (86% versus 56%) and at 30 days (71% versus 56%), but similar at 1 year (57% versus 56%). During follow-up, 1 patient in each group required reintervention for residual VSD (hybrid: 9 months versus surgical: 5 days). CONCLUSIONS: Early intervention with a hybrid transcatheter/surgical repair may be a viable alternative to traditional surgery for postinfarction apical VSD.


Assuntos
Infarto Miocárdico de Parede Anterior , Comunicação Interventricular , Infarto do Miocárdio , Dispositivo para Oclusão Septal , Humanos , Resultado do Tratamento , Cateterismo Cardíaco , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/etiologia , Comunicação Interventricular/cirurgia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/terapia
14.
Ann Thorac Surg ; 113(1): 337-365, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34711394

RESUMO

Data for nearly all patients undergoing transcatheter edge-to-edge repair (TEER) and transcatheter mitral valve replacement (TMVR) with an approved device in the United States is captured in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. All data submitted for TEER or TMVR between 2014 and March 31, 2020, are reported. A total of 37,475 patients underwent a mitral transcatheter procedure, including 33,878 TEER and 3,597 TMVR. Annual procedure volumes for TEER have increased from 1,152 per year in 2014 to 10,460 per year in 2019 at 403 sites and for TMVR from 84 per year to 1,120 per year at 301 centers. Mortality rates have decreased for TEER at 30 days (5.6%-4.1%) and 1 year (27.4%-22.0%). Early off-label use data on TMVR in mitral valve-in-valve therapy led to approval by the U.S. Food and Drug Administration in 2017, and the 2019 30-day mortality rate was 3.9%. Overall improvements in outcomes over the last 6 years are apparent. (STS/ACC TVT Registry Mitral Module; NCT02245763).


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Sistema de Registros , Estados Unidos
15.
J Heart Valve Dis ; 20(3): 272-81, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21714416

RESUMO

BACKGROUND AND AIM OF THE STUDY: Mitral regurgitation (MR) is frequently present in patients with calcific aortic stenosis (AS). Yet, the issue of whether to surgically correct the MR during aortic valve replacement (AVR) remains uncertain. The study aim was to define the outcome of MR after transcatheter aortic valve implantation (TAVI) in the TRanscatheter EndoVascular Implantation of VALves (REVIVAL) II trial. METHODS: Echocardiography was performed before and at 24 h, and three and six months after valve implantation. The degree of MR was evaluated by expert readers and by the vena contracta (VC) method. Significant MR was defined as at least mild to moderate MR. Those patients with a 30% reduction in VC were classified as good responders (GR group), and the remainder as poor responders (PR group). RESULTS: The study comprised 35 subjects with at least mild to moderate MR before TAVI. The mean VC of the whole group declined from 0.5 +/- 0.2 cm initially to 0.32 +/- 0.2 cm and 0.38 +/- 0.2 cm at 24 h and three months, respectively (p < 0.05). At three months, 12 patients had > 30% VC reduction; these constituted the GR group, while the remainder constituted the PR group. The percentage of patients with mitral annular calcification with restriction (MACr), defined as calcification encroaching onto the leaflets and restricting leaflet motion, was significantly lower in the GR group compared to the PR group (17% versus 61%, respectively; p < 0.05). The remaining pre-specified parameters did not differ significantly between the GR and PR groups, including age, gender, mitral valve tethering height and area (6 +/- 2 mm versus 5 +/- 3 mm and 10 +/- 4 mm2 versus 13 +/- 9 and 10 +/- 4 mm2, respectively), change in the aortic valve area (336 +/- 130% versus 285 +/- 180%), change in mean systolic aortic valve pressure (-20 +/- 8% versus - 23 +/- 10%), and left ventricular ejection fraction (47 +/- 15% versus 45 +/- 18%). CONCLUSION: MR is improved significantly after TAVI for AS. MACr was the only variable associated with a reduction in MR improvement. These results suggest that a careful echocardiographic evaluation of the mitral valve prior to TAVI may help to predict which patients should experience an improvement in their MR.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/complicações , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/instrumentação , Distribuição de Qui-Quadrado , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Desenho de Prótese , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
16.
JTCVS Open ; 7: 51-60, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36003692

RESUMO

Objectives: To compare echocardiographic and invasive mean gradients obtained concomitantly in degenerated bioprosthetic surgical aortic valves (SAVRs). Methods: In a multicenter study, we compared concomitant echocardiographic and invasive mean gradients of SAVR, obtained before valve-in-valve transcatheter aortic valve replacement in all patients, patients with primary stenosis (AS), primary aortic regurgitation (AR), and mixed aortic valve disease (MAVD), and in small versus large valves (≤ or >23 mm). Dimensionless index (DI) was calculated in all groups. Results: In total, 74 patients were included and data presented as median (interquartile range). Echocardiography-catheterization mean gradient discordance was observed in all patients (invasive = 22 mm Hg [11-34] vs echocardiographic = 32 mm Hg [21-42], P = .013), small valves (invasive = 15 mm Hg [8-34] vs echocardiographic = 28 mm Hg [21-41], P = .013), and large valves (invasive = 20 mm Hg [8.5-27.13] vs echocardiographic = 32 mm Hg [25.5 - 41.5], P < .0001), with a bias of 8 ± 15 mm Hg and wide limits of agreement (-22 to 39 mm Hg) on Bland-Altman plots, indicating these modalities may not be interchangeable. Discordance occurred in AR (invasive = 3 mm Hg [1-6] vs echocardiographic = 12 mm Hg [7-22], P = .017) and in MAVD (invasive = 19 mm Hg [12-29] vs echocardiographic = 31 mm Hg [23-39], P < .0001) but not in AS (invasive = 35 mm Hg [24-45] vs echocardiographic = 41 mm Hg [30-50], P = .45). A lower DI (0.21 [0.14-0.25]) occurred in AS compared with MAVD (0.31 [0.19-0.39]) and AR (0.55 [0.51-0.69]), P < .0001. Conclusions: Discordance between echocardiography and invasive mean gradients exists in degenerated SAVR, regardless of valve size, but depends on mechanism of failure and DI helps stratify these patients. With a discrepancy between echocardiographic mean gradients AND the patient's symptoms OR the valve leaflet structure and/or mobility on imaging, especially before redo-SAVR or valve-in-valve transcatheter aortic valve replacement, invasive gradients may adjudicate the true valvular hemodynamics.

17.
PLoS One ; 16(6): e0250801, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34106945

RESUMO

BACKGROUND: Cigarette smoking, hypertension, dyslipidemia, diabetes, and obesity are conventional risk factors (RFs) for coronary artery disease (CAD). Population trends for these RFs have varied in recent decades. Consequently, the risk factor profile for patients presenting with a new diagnosis of CAD in contemporary practice remains unknown. OBJECTIVES: To examine the prevalence of RFs and their temporal trends among patients without a history of myocardial infarction or revascularization who underwent their first percutaneous coronary intervention (PCI). METHODS: We examined the prevalence and temporal trends of RFs among patients without a history of prior myocardial infarction, PCI, or coronary artery bypass graft surgery who underwent PCI at 47 non-federal hospitals in Michigan between 1/1/2010 and 3/31/2018. RESULTS: Of 69,571 men and 38,930 women in the study cohort, 95.5% of patients had 1 or more RFs and nearly half (55.2% of women and 48.7% of men) had ≥3 RFs. The gap in the mean age at the time of presentation between men and women narrowed as the number of RFs increased with a gap of 6 years among those with 2 RFs to <1 year among those with 5 RFs. Compared with patients without a current/recent history of smoking, those with a current/recent history of smoking presented a decade earlier (age 56.8 versus 66.9 years; p <0.0001). Compared with patients without obesity, patients with obesity presented 4.0 years earlier (age 61.4 years versus 65.4 years; p <0.0001). CONCLUSIONS: Modifiable RFs are widely prevalent among patients undergoing their first PCI. Smoking and obesity are associated with an earlier age of presentation. Population-level interventions aimed at preventing obesity and smoking could significantly delay the onset of CAD and the need for PCI.


Assuntos
Doença das Coronárias/prevenção & controle , Fatores de Risco de Doenças Cardíacas , Intervenção Coronária Percutânea/estatística & dados numéricos , Prevenção Primária , Adulto , Fatores Etários , Idoso , Doença das Coronárias/etiologia , Doença das Coronárias/cirurgia , Feminino , Humanos , Masculino , Michigan/epidemiologia , Pessoa de Meia-Idade , Obesidade/epidemiologia , Prevalência , Prevenção Primária/métodos , Fatores Sexuais , Fumar/epidemiologia
18.
J Am Heart Assoc ; 10(19): e021014, 2021 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-34585593

RESUMO

Background Concerns about discordance between echocardiographic and invasive mean gradients after transcatheter aortic valve replacement (TAVR) with balloon-expandable valves (BEVs) versus self-expanding valves (SEVs) exist. Methods and Results In a multicenter study, direct-invasive and echocardiography-derived transvalvular mean gradients obtained before and after TAVR were compared as well as post-TAVR and discharge echocardiographic mean gradients in BEVs versus SEVs in 808 patients. Pre-TAVR, there was good correlation (R=0.614; P<0.0001) between direct-invasive and echocardiography-derived mean gradients and weak correlation (R=0.138; P<0.0001) post-TAVR. Compared with post-TAVR echocardiographic mean gradients, both valves exhibit lower invasive and higher discharge echocardiographic mean gradients. Despite similar invasive mean gradients, a small BEV exhibits higher post-TAVR and discharge echocardiographic mean gradients than a large BEV, whereas small and large SEVs exhibit similar post-TAVR and discharge mean gradients. An ejection fraction <50% (P=0.028) and higher Society of Thoracic Surgeons predicted risk of mortality score (P=0.007), but not invasive or echocardiographic mean gradient ≥10 mm Hg (P=0.378 and P=0.341, respectively), nor discharge echocardiographic mean gradient ≥20 mm Hg (P=0.393), were associated with increased 2-year mortality. Conclusions Invasively measured and echocardiography-derived transvalvular mean gradients correlate well in aortic stenosis but weakly post-TAVR. Post-TAVR, echocardiography overestimates transvalvular mean gradients compared with invasive measurements, and poor correlation suggests these modalities cannot be used interchangeably. Moreover, echocardiographic mean gradients are higher on discharge than post-TAVR in all valves. Despite similar invasive mean gradients, a small BEV exhibits higher post-TAVR and discharge echocardiographic mean gradients than a large BEV, whereas small and large SEVs exhibit similar post-TAVR and discharge mean gradients. Immediately post-TAVR, elevated echocardiographic-derived mean gradients should be assessed with caution and compared with direct-invasive mean gradients. A low ejection fraction and higher Society of Thoracic Surgeons score, but not elevated mean gradients, are associated with increased 2-year mortality.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Hemodinâmica , Humanos , Desenho de Prótese , Resultado do Tratamento
19.
Ann Thorac Surg ; 111(2): 701-722, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33213826

RESUMO

The STS-ACC TVT Registry (Society of Thoracic Surgeons-American College of Cardiology Transcatheter Valve Therapy Registry) from 2011 to 2019 has collected data on 276,316 patients undergoing transcatheter aortic valve replacement (TAVR) at sites in all U.S. states. Volumes have increased every year, exceeding surgical aortic valve replacement in 2019 (72,991 vs. 57,626), and it is now performed in all U.S. states. TAVR now extends from extreme- to low-risk patients. This is the first presentation on 8,395 low-risk patients treated in 2019. In 2019, for the entire cohort, femoral access increased to 95.3%, hospital stay was 2 days, and 90.3% were discharged home. Since 2011, the 30-day mortality rate has decreased (7.2% to 2.5%), stroke has started to decrease (2.75% to 2.3%), but pacemaker need is unchanged (10.9% to 10.8%). Alive with acceptable patient-reported outcomes is achieved in 8 of 10 patients at 1 year. The Registry is a national resource to improve care and analyze TAVR's evolution. Real-world outcomes, site performance, and the impact of coronavirus disease 2019 will be subsequently studied. (STS/ACC Transcatheter Valve Therapy Registry [TVT Registry]; NCT01737528).


Assuntos
Sistema de Registros , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Ponte Cardiopulmonar , Feminino , Nível de Saúde , Humanos , Tempo de Internação , Masculino , Marca-Passo Artificial , Acidente Vascular Cerebral/epidemiologia , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estados Unidos/epidemiologia
20.
J Am Coll Cardiol ; 78(23): 2326-2353, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34711430

RESUMO

Data for nearly all patients undergoing transcatheter edge-to-edge repair (TEER) and transcatheter mitral valve replacement (TMVR) with an approved device in the United States is captured in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. All data submitted for TEER or TMVR between 2014 and March 31, 2020, are reported. A total of 37,475 patients underwent a mitral transcatheter procedure, including 33,878 TEER and 3,597 TMVR. Annual procedure volumes for TEER have increased from 1,152 per year in 2014 to 10,460 per year in 2019 at 403 sites and for TMVR from 84 per year to 1,120 per year at 301 centers. Mortality rates have decreased for TEER at 30 days (5.6%-4.1%) and 1 year (27.4%-22.0%). Early off-label use data on TMVR in mitral valve-in-valve therapy led to approval by the U.S. Food and Drug Administration in 2017, and the 2019 30-day mortality rate was 3.9%. Overall improvements in outcomes over the last 6 years are apparent. (STS/ACC TVT Registry Mitral Module; NCT02245763).


Assuntos
Cateterismo Cardíaco/estatística & dados numéricos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Sistema de Registros , Cirurgia Torácica/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Feminino , Mortalidade Hospitalar/tendências , Humanos , Incidência , Masculino , Insuficiência da Valva Mitral/epidemiologia , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA