Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39072400

RESUMO

OBJECTIVES: Assessment of Wilson disease is complicated, with neither ceruloplasmin, nor serum or urine copper, being reliable. Two new indices, accurate non-ceruloplasmin copper (ANCC) and relative ANCC were developed and applied to a cohort of 71 patients, as part of a Wilson Disease Registry Study. METHODS: Elemental copper-protein speciation was developed for holo-ceruloplasmin quantitation using strong anion exchange chromatography coupled to triple quadrupole inductively coupled plasma mass spectrometry. The serum proteins were separated using gradient elution and measured at m/z 63 (63Cu+) and 48 (32S16O+) using oxygen reaction mode and Cu-EDTA as calibration standard. The ANCC was calculated by subtraction of the ceruloplasmin bound copper from the total serum copper and the RelANCC was the percentage of total copper present as the ANCC. RESULTS: The accuracy of the holo-ceruloplasmin measurement was established using two certified reference materials, giving a mean recovery of 94.2 %. Regression analysis between the sum of the copper containing species and total copper concentration in the patient samples was acceptable (slope=0.964, intercept=0, r=0.987) and a difference plot, gave a mean difference for copper of 0.38 µmol/L. Intra-day precision for holo-ceruloplasmin at serum copper concentrations of 0.48 and 3.20 µmol/L were 5.2 and 5.6 % CV and the intermediate precision at concentrations of 0.80 and 5.99 µmol/L were 6.4 and 6.4 % CV, respectively. The limit of detection (LOD) and lower limit of quantification (LLOQ) for holo-ceruloplasmin were 0.08 and 0.27 µmol/L as copper, respectively. CONCLUSIONS: ANCC and Relative ANCC are important new diagnostic and monitoring biomarker indices for Wilson disease (WD).

2.
Clin Chem Lab Med ; 54(12): 1921-1928, 2016 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-27174868

RESUMO

BACKGROUND: Proficiency testing or external quality assessment schemes (PT/EQASs) are an important method of assessing laboratory performance. As each scheme establishes assigned values and acceptable ranges for the analyte according to its own criteria, monitoring of participant performance varies according to the scheme and can lead to conflicting conclusions. METHODS: Standard deviations (SDs) for PT were derived from Thompson's and biological variation models applied to blood and urine manganese (Mn) robust data from four EQASs from North America and Europe. The fitness for purpose was verified by applying these SDs to individual results. RESULTS: Using Thompson characteristic function the relationship between SD and Mn concentration, expressed in nmol/L was the square root of [19.72+(0.07712×Mn concentration2)] for blood and the square root of [6.772+(0.09852×Mn concentration2)] for urine. While the biological variation model was not suitable for urine, it produced an acceptable range for blood as ±54.4 nmol/L (assigned value ≤320 nmol/L) or 17% (assigned value >320 nmol/L). For blood, individual performance evaluated by the two approaches led to similar conclusions. CONCLUSIONS: The biological variation model can be used to propose quality specifications for blood, however it could not be applied to urine. The Thompson characteristic function model could be applied to derive quality specifications for Mn in urine and, to a lesser extent in blood. The more lenient quality specifications for blood highlight the difficulty of determining Mn in this matrix. Further work is needed to harmonize PT, such as using assigned ranges for the specimens.


Assuntos
Técnicas de Laboratório Clínico/normas , Manganês/sangue , Manganês/urina , Humanos
3.
Anal Bioanal Chem ; 407(16): 4541-54, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25874977

RESUMO

Hip replacements are used to improve the quality of life of people with orthopaedic conditions, but the use of metal-on-metal (MoM) arthroplasty has led to poor outcomes for some patients. These problems are related to the generation of micro- to nanosized metal wear particles containing Cr, Co or other elements, but the current analytical methods used to investigate the processes involved do not provide sufficient information to understand the size or composition of the wear particles generated in vivo. In this qualitative feasibility study, asymmetric flow field-flow fractionation (AF(4)) coupled with inductively coupled plasma mass spectrometry (ICP-MS) was used to investigate metal protein binding and the size and composition of wear metal particles present in serum and hip aspirates from MoM hip replacement patients. A well-established HPLC anion exchange chromatography (AEC) separation system coupled to ICP-MS was used to confirm the metal-protein associations in the serum samples. Off-line single particle ICP-MS (spICP-MS) analysis was used to confirm the approximate size distribution indicated by AF(4) of the wear particles in hip aspirates. In the serum samples, AF(4) -ICP-MS suggested that Cr was associated with transferrin (Tf) and Co with albumin (Alb) and an unidentified species; AEC-ICP-MS confirmed these associations and also indicated an association of Cr with Alb. In the hip aspirate sample, AF(4)-ICP-MS suggested that Cr was associated with Alb and Tf and that Co was associated with Alb and two unidentified compounds; AEC analysis confirmed the Cr results and the association of Co with Alb and a second compound. Enzymatic digestion of the hip aspirate sample, followed by separation using AF(4) with detection by UV absorption (280 nm), multi-angle light scattering and ICP-MS, suggested that the sizes of the Cr-, Co- and Mo-containing wear particles in a hip aspirate sample were in the range 40-150 nm. Off-line spICP-MS was used to confirm these findings for the Co- and Cr-containing nanoparticles. Whilst limited in scope, the results are sufficient to show the interaction of ions with transport proteins and give an indication of particle size, providing useful pathological indices. As such, the methods indicate a new way forward for in vivo investigation of the processes which lead to tissue necrosis and hip loosening in patients with MoM hip replacements.


Assuntos
Artroplastia de Quadril , Líquidos Corporais/química , Fracionamento por Campo e Fluxo , Metaloproteínas/análise , Metais/análise , Estudos de Viabilidade , Humanos , Espectrometria de Massas
4.
Crit Rev Anal Chem ; : 1-18, 2023 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-36637361

RESUMO

Advances in inductively coupled plasma mass spectrometry and the methods used to prepare isotopically enriched standards, allow for the high accuracy measurement of metalloproteins by isotope dilution mass spectrometry. This technique has now reached a level of maturity whereby a step change in the accuracy, precision, and traceability of, in particular, clinical, and biomedical measurements is achievable. Current clinical measurements, which require low limits of detection in the presence of complex sample matrices, use indirect methods based on immunochemistry for the study of human disease. However, this approach suffers from poor traceability, requiring comparisons based on provision of matrix-based reference materials, used as analytical standards. This leads to difficulty when changes in the reference material are required, often resulting in a lack of interlaboratory and temporal comparability in clinical results and reference ranges. In this review, we focus on the most important metalloproteins for clinical studies, to illustrate how the attributes of chromatography coupled to inorganic mass spectrometry can be used for the direct measurement of metalloproteins such as hemoglobin, transferrin, and ceruloplasmin. By using this approach, we hope to demonstrate how isotope dilution analysis can be used as a reference method to improve traceability and underpin clinical, biomedical, and other biological measurements.

5.
Maedica (Bucur) ; 16(2): 207-210, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34621341

RESUMO

Aim: This report aims to render a proposed concept model for cancer risk in Nigerian electronic waste exposure by making deductions from data on the assessment of Nigerians' exposure to toxic metals in e-waste, using biomarkers of exposure and genotoxicity to evaluate the risk of cancer development. Material and methods: In the cross-sectional study, 632 consenting participants, consisting of 381 e-waste workers (EW) and 120 environmental e-waste exposed participants (EEEP), age-matched with 131 unexposed participants (controls), were enrolled from Benin, Lagos and Ibadan, Southwestern Nigeria. Levels of selected toxic metals in blood and essential metals in serum were determined using inductively coupled plasma-mass spectrometry. Oxidative stress biomarkers, including malondialdehyde and uric acid (UA), and activities of enzymatic antioxidants [catalase, superoxide dismutase (SOD), γ-glutamyltransferase (GGT) and glutathione peroxidase (GPx)], were determined in serum using standard methods like spectrophotometry. Genotoxicity biomarkers - wild-type tumour suppressor protein (wt-p53), 8-oxoguanine-DNA glycosylase (OGG1), and 8-hydroxy-2'-deoxyguanosine (8-OHdG); glutathione (GSH); and tumour markers [prostate-specific antigen (PSA) and alpha-fetoprotein] - were determined in serum using ELISA. Micronucleus assay was carried out using microscopy. Data were analysed using ANOVA and Pearson's correlation coefficient at α0.05. Results: There was evidence indicating elevated levels of genotoxic toxic metals, decreased levels of genome protective metals, increased oxidative stress markers as well as reduced cellular antioxidants in both EW and EEEP compared to controls. Additionally, the levels of wt-p53 in EW and EEEP were lower than controls, while OGG1 activity in EEEP was higher. The PSA and alpha-fetoprotein in EW were more elevated than EEEP and controls, respectively. The MnPCE/1000PCE in EW was higher than EEEP and controls. Conclusion: The proposed schematic model could be adopted to illustrate cancer risk in Nigerian population exposed to electronic waste.

6.
Chem Res Toxicol ; 23(8): 1313-21, 2010 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-20666396

RESUMO

Platinum-containing drugs are widely used to treat cancer in a variety of clinical settings. Their mode of action involves the formation of DNA adducts, which facilitate apoptosis in cancer cells. Cisplatin binds to the N7 position of the purine DNA bases forming intrastrand cross-links between either two adjacent guanines [cis-Pt(NH(3))(2)d(pGpG), 1,2-GG] or an adjacent adenine and guanine [cis-Pt(NH(3))(2)d(pApG), 1,2-AG)]. The cytotoxic efficacy for each of the different types of DNA adducts and the relationship between adduct levels in tumor cells and blood are not well understood. By using these Pt-containing adduct species as biomarkers, information on a patient's response to chemotherapy would be directly related to the mode of action of the drug. This type of analysis requires the most sensitive and specific methods available, to facilitate detection limits sufficient to measure the DNA adduct in the limited sample quantities available from patients. This was achieved in the current study by coupling a highly specific enzyme-based adduct isolation method with a sensitive detection system based on HPLC coupled to inductively coupled plasma mass spectrometry to measure the 1,2-GG cisplatin adducts formed in DNA. The method was developed and validated using calf thymus DNA and two different adenocarcinoma cell lines. The values for the limit of detection (LOD) and the limit of quantitation determined for the 1,2-GG cisplatin adduct were 0.21 and 0.67 fmol per microg DNA, respectively. This corresponds to an absolute LOD of 0.8 pg as Pt for the 1,2-GG adduct. Cisplatin-sensitive (H23) and -resistant (A549) tumor cells were exposed to the drug, and the 1,2-GG adduct levels were measured over a 24 h time period. The results showed a statistically significant (P < 0.05) higher concentration in the sensitive cells as compared to the resistant cells after repair for 7 h. Although the adduct concentration present fell at subsequent time points (12 and 24 h), the levels in each cell line were broadly similar. The protocol was then applied to the analysis of patient samples taken before and then 1 h after treatment. The 1,2-GG cisplatin adduct was present in the range from 113 to 1245 fg Pt per microg DNA in all of the patient samples taken after treatment. Although the adduct was not present at levels greater than the LOD in the initial pretreatment samples, trace amounts were discernible in some patient samples on their third treatment cycle.


Assuntos
Antineoplásicos/análise , Cisplatino/análise , Adutos de DNA/análise , Adutos de DNA/química , Guanina/química , Leucócitos/metabolismo , Animais , Antineoplásicos/química , Antineoplásicos/farmacologia , Bovinos , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Cromatografia Líquida de Alta Pressão , Cisplatino/química , Cisplatino/farmacologia , DNA/química , DNA/efeitos dos fármacos , Adutos de DNA/farmacologia , DNA de Neoplasias/efeitos dos fármacos , DNA de Neoplasias/genética , Ensaios de Seleção de Medicamentos Antitumorais , Humanos , Leucócitos/citologia , Leucócitos/efeitos dos fármacos , Espectrometria de Massas , Sensibilidade e Especificidade
7.
Mutat Res ; 696(2): 95-100, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20015476

RESUMO

Earthworms native to the former mine site of Devon Great Consols (DGC), UK reside in soils highly contaminated with arsenic (As). These earthworms are considered to have developed a resistance to As toxicity. The mechanisms underlying this resistance however, remain unclear. In the present study, non-resistant, commercially sourced Lumbricus terrestris were exposed to a typical DGC soil in laboratory mesocosms. The earthworms bio-accumulated As from the soil and incurred DNA-damage levels significantly above those observed in the control mesocosm (assessed using the Comet assay). A dose response was observed between DNA damage (% tail DNA) and As concentration in soil (control, 98, 183, 236, 324 and 436mgkg(-1)). As-resistant earthworms (Lumbricus rubellus, Dendrodrilus rubidus and L. terrestris) collected from contaminated soils at DGC (203 to 9025mgkg(-1) As) had also bio-accumulated high levels of As from their host soils, yet demonstrated low levels of DNA damage compared with earthworms from uncontaminated sites. The results demonstrate that the As-contaminated soils at DGC are genotoxic to non-native earthworms and much less so to earthworms native to DGC, thus providing further evidence of an acquired resistance to As toxicity in the native earthworms.


Assuntos
Arsênio/toxicidade , Dano ao DNA , Oligoquetos/genética , Poluentes do Solo/toxicidade , Animais , Ensaio Cometa , Relação Dose-Resposta a Droga , Mineração
8.
Anal Chim Acta ; 1098: 27-36, 2020 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-31948584

RESUMO

Biomedical analytical methods often rely on indirect measurements, such as immunoassays, which can lack effective metrological traceability. In the nephelometric determination of ceruloplasmin (Cp), an important protein whose circulating level is altered in Wilson's disease (WD), the anti-Cp antibody used is not specific for the biologically active holoprotein so the assay can overestimate the concentration of Cp due to the presence of the apoprotein. By providing quantitation using elemental standards, the use of strong anion exchange chromatography (SAX) coupled to triple quadrupole inductively coupled plasma mass spectrometry (ICP-MS-MS) can overcome the drawbacks of methods for the measurement of metalloproteins reliant on immunoassays. In the current study, a SAX-ICP-MS-MS method for Cp quantification was designed and tested in samples of blood serum of WD patients and healthy controls. Using standards based on a copper-EDTA complex for calibration, the method provides relatively simple quantification of Cp with the limit of detection of 0.1 µg L-1 (limit of quantification 0.4 µg L-1). The method was also used to investigate the copper species separated by using a 30 kDa cut-off ultrafiltration device. The so-called "exchangeable" copper fraction is considered as an alternative clinical biomarker of WD. Using the designed speciation approach, it was shown that the ultrafiltration method can overestimate the "exchangeable" copper fraction due to a removal of copper from Cp. This was confirmed by comparing the enzymatic activity of the fractions. Thus, the specificity of the "exchangeable" copper test can be ensured only under strict maintenance of ultrafiltration conditions.


Assuntos
Pesquisa Biomédica , Cobre/sangue , Degeneração Hepatolenticular/sangue , Cromatografia por Troca Iônica/instrumentação , Degeneração Hepatolenticular/diagnóstico , Humanos , Espectrometria de Massas/instrumentação
9.
J Environ Monit ; 11(3): 610-7, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19280039

RESUMO

A pilot study was conducted to determine the applicability of toenails as a biomarker of exposure to elevated environmental arsenic (As) levels. A total of 17 individuals were recruited for the pilot study: 8 residents living near to a former As mine, Devon, UK, forming the exposed group, plus 9 residents from Nottinghamshire, UK, with no anticipated As exposure who were used for comparison as a control group. All toenail samples were thoroughly washed prior to analysis and the wash solutions retained for As determination via ICP-MS to provide an indication of the background environmental As levels for each group. Total As was determined in washed toenail samples via ICP-MS following microwave assisted acid digestion. Concentrations of total As in the toenails of the exposed group were elevated, ranging from 858 to 25 981 microg kg(-1) (geometric mean = 5406 microg kg(-1)), compared to the control group whose toenail As concentrations ranged from 73 to 273 microg kg(-1) (geometric mean = 122 microg kg(-1)). Higher levels of exogenous As contamination were present on the toenails of the exposed group (geometric mean = 506 microg kg(-1)) compared to the control group (geometric mean = 4.0 microg kg(-1)) providing evidence of higher environmental As levels in the exposed group. Total As concentrations in toenail samples were positively correlated to environmental As levels (r = 0.60, p < 0.001). HPLC-ICP-MS analysis of aqueous toenail extracts revealed inorganic arsenite (As(III)) to be the dominant species extracted ( approximately 83%) with lesser amounts of inorganic arsenate (As(V)) and organic dimethylarsinate (DMA(V)) at approximately 13% and approximately 8.5%, respectively. Arsenic speciation in analysed toenail extracts from the two groups was comparable. The only notable difference between groups was the presence of small amounts (<1%) of organic methylarsonate (MA(V)) in two toenail samples from the exposed group. Toenails are presented as a viable biomarker of exposure at sites with elevated environmental As, such as the former mining sites found throughout Devon and Cornwall, UK.


Assuntos
Arsênio/química , Exposição Ambiental , Monitoramento Ambiental/métodos , Unhas/química , Adulto , Idoso , Biomarcadores , Poluentes Ambientais/química , Poluentes Ambientais/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mineração , Projetos Piloto , Reino Unido , Adulto Jovem
10.
J Environ Monit ; 11(8): 1484-91, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19657532

RESUMO

Two species of arsenic (As) resistant earthworm, Lumbricus rubellus and Dendrodrillus rubidus, their host soils and soil excretions (casts) were collected from 23 locations at a former As mine in Devon, UK. Total As concentrations, measured by ICP-MS, ranged from 255 to 13,080 mg kg(-1) in soils, 11 to 877 mg kg(-1) in earthworms and 284 to 4221 mg kg(-1) in earthworm casts from a sub-sample of 10 of the 23 investigated sites. The samples were also measured for As speciation using HPLC-ICP-MS to investigate potential As biotransformation pathways. Inorganic arsenate (As(V)) and arsenite (As(III)) were the only species detected in the soil. As(V) and As(III) were also the dominant species found in the earthworms and cast material together with lower proportions of the organic species methylarsonate (MA(V)), dimethylarsinate (DMA(V)), arsenobetaine (AB) and three arsenosugars. Whilst the inorganic As content of the earthworms increased with increasing As body burden, the concentration of organic species remained relatively constant. These results suggest that the biotransformation of inorganic arsenic to organic species does not contribute to As resistance in the sampled earthworm populations. Quantification of As speciation in the soil, earthworms and cast material allows a more comprehensive pathway for the formation of AB in earthworms to be elucidated.


Assuntos
Arsênio/metabolismo , Oligoquetos/metabolismo , Poluentes do Solo/metabolismo , Solo/análise , Animais , Arseniatos/análise , Arsênio/análise , Arsenitos/análise , Biotransformação , Monitoramento Ambiental , Poluentes do Solo/análise
11.
Environ Geochem Health ; 31(2): 273-82, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18958400

RESUMO

The relationship of the total arsenic content of a soil and its bioaccumulation by earthworms (Lumbricus rubellus and Dendrodrilus rubidus) to the arsenic fraction bioaccessible to humans, measured using an in vitro physiologically-based extraction test (PBET), was investigated. Soil and earthworm samples were collected at 24 sites at the former arsenic mine at the Devon Great Consols (DGC) in southwest England (UK), along with an uncontaminated site in Nottingham, UK, for comparison. Analysis of soil and earthworm total arsenic via inductively coupled plasma mass spectrometry (ICP-MS) was performed following a mixed acid digestion. Arsenic concentrations in the soil were elevated (204-9,025 mg kg(-1)) at DGC. The arsenic bioaccumulation factor (BAF) for both earthworm species was found to correlate positively with the human bioaccessible fraction (HBF), although the correlation was only significant (P < or = 0.05) for L. rubellus. The potential use of both in vitro PBETs and earthworms as complementary tools is explored as a holistic and multidisciplinary approach towards understanding risk at contaminated sites. Arsenic resistant earthworm species such as the L. rubellus populations at DGC are presented as a valuable tool for understanding risk at highly contaminated sites.


Assuntos
Arsênio/toxicidade , Oligoquetos , Poluentes do Solo/toxicidade , Animais , Arsênio/análise , Arsênio/farmacocinética , Disponibilidade Biológica , Inglaterra , Monitoramento Ambiental , Medição de Risco , Poluentes do Solo/análise , Poluentes do Solo/farmacocinética , Distribuição Tecidual
12.
J Environ Monit ; 10(6): 753-9, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18528543

RESUMO

The relationship between the total arsenic concentration and the chemical speciation of arsenic in two species of earthworm (Lumbricus rubellus and Dendrodrilus rubidus) in relation to the host soil, was investigated for 13 sites of varying arsenic content, including a background level garden soil and a former mine site at the Devon Great Consols, UK. Earthworms were collected with the host soil (As soil concentration range 16-12, 466 mg kg(-1) dry weight) and measured for their total arsenic (concentration range 7-595 mg kg(-1) dry weight) using inductively coupled plasma mass spectrometry (ICP-MS). A methanol-water mixture was used to extract arsenic species from the earthworms prior to determination of the individual arsenic species by a combination of anion and cation exchange high performance liquid chromatography coupled to inductively coupled plasma mass spectrometry (HPLC-ICP-MS). A gradient elution anion exchange method is presented whereby nine arsenic species could be measured in one sample injection. Arsenic species were identified by comparison of retention times and sample spiking with known standards and a fully characterised seaweed extract. Arsenic was generally present in the earthworm as arsenate (As(V)) or arsenite (As(III)) and arsenobetaine (AB). Methylarsonate (MA), dimethylarsinate (DMA) and three arsenosugars (glycerol, phosphate, sulfate) were present as minor constituents. These results are discussed in relation to the mechanisms for coping with exposure to soil bound arsenic.


Assuntos
Arseniatos/toxicidade , Arsênio/toxicidade , Arsenicais/efeitos adversos , Monitoramento Ambiental , Oligoquetos/efeitos dos fármacos , Poluentes do Solo , Animais , Arseniatos/farmacocinética , Arsênio/farmacocinética , Arsenicais/farmacocinética , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas , Mineração , Monossacarídeos , Oligoquetos/metabolismo , Alga Marinha/química , Poluentes do Solo/análise , Poluentes do Solo/farmacocinética , Poluentes do Solo/toxicidade
13.
Ann Clin Biochem ; 54(3): 362-369, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27422134

RESUMO

Background Patients with metal-on-metal hip replacements require testing for cobalt and chromium. There may also be a need to test for titanium, which is used in the construction of the femoral stem in total hip replacements. It is not possible to use quadrupole inductively coupled plasma mass spectrometry due to interferences. Methods Titanium was measured using inductively coupled plasma optical emission spectroscopy using the emission line at 336.1 nm and Y (internal standard) at 371.0 nm. Internal quality control materials were prepared for blood and serum and concentrations assigned using a sector field-inductively coupled plasma mass spectrometer. A candidate whole blood certified reference material was also evaluated. Results The method had detection and quantitation limits of 0.6 and 1.9 µg/L, respectively. The respective bias (%) and measurement uncertainty ( U) (k = 2) were 3.3% and 2.0 µg/L (serum) and - 1.0% and 1.4 µg/L (whole blood). The respective repeatability and intermediate precision (%) were 5.1% and 10.9% (serum) and 2.4% and 8.6% (whole blood). The concentration of titanium was determined in patients' samples, serum (median = 2.4 µg/L, n = 897) and whole blood (median = 2.4 µg/L, n = 189). Serum is recommended for monitoring titanium in patients, since the concentration is higher than in whole blood and the matrix less problematic. In hip fluid samples, the concentrations were much higher (mean 58.5 µg/L, median 5.1 µg/L, n = 83). Conclusions A method based on inductively coupled plasma optical emission spectroscopy was developed and validated for measuring titanium in clinical samples.


Assuntos
Artroplastia de Quadril , Espectrofotometria Atômica/normas , Titânio/sangue , Cromo/sangue , Cobalto/sangue , Feminino , Prótese de Quadril , Humanos , Limite de Detecção , Masculino , Controle de Qualidade , Padrões de Referência
14.
J Pharm Biomed Anal ; 106: 210-7, 2015 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-25455724

RESUMO

Many pharmaceuticals contain metals, either as part of the active compound or within the formulation. They are also found in related products such as dietary supplements and toiletries. Concentrations of metals in biological fluids or tissues from patients taking these agents, are measured where there may be an adverse reaction, dose-related toxicity or for therapeutic drug monitoring. Other situations, for analysis of environmental samples include occupational exposure (manufacture, administration to patients, pharmaceutical research) or in investigations of poisoning. Highly sensitive and accurate analytical methods are now available to determine the total metal concentration in a specific sample, but also to measure the specific chemical form of the drug, a metabolite of the drug, or the drug's interaction with important cellular components, such as DNA. The use of ICP-MS to measure total metal concentrations, or HPLC coupled to ICP-MS for the more complex speciation measurements, will depend on the type of information that is required. For the investigation of the drug species present, other complementary analytical techniques such as electrospray mass spectrometry (LC-MS/MS) are required for a full structural elucidation of the analytes. In this current publication we highlight the measurement of two metal(loid) based pharmaceutical drugs for the treatment of cancer. One 4-(N-(S-glutathionylacetyl)amino) phenylarsenoxide (GSAO) containing arsenic and under investigation for the treatment of solid tumours, and the second cis-diamminedichloroplatinum (II) (cisplatin) containing platinum and widely used in the clinical setting as a front line treatment against various neplasias in particular testicular, ovarian, bladder and head and neck cancers.


Assuntos
Antineoplásicos/análise , Arsenicais/análise , Cisplatino/análise , Glutationa/análogos & derivados , Animais , Cromatografia Líquida/métodos , Glutationa/análise , Humanos , Espectrometria de Massas/métodos , Espectrofotometria Atômica/métodos
15.
J AOAC Int ; 87(1): 253-8, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15084108

RESUMO

Quantitative determination was made of the iron-containing protein myoglobin in a range of different foods, including meat, processed meat, fish, and shellfish, by liquid chromatography coupled to a double-focusing sector field inductively coupled plasma mass spectrometry (ICP-MS). The concentration of myoglobin determined in the samples ranged from 0 to 6.5 mg/kg, and the analytical precision (coefficient of variation) for the analysis of 8 replicate raw steak extracts was 2.1%. By using a double-focusing ICP-MS instrument, direct on-line detection of the most abundant iron isotope 56Fe was possible without interference from a major polyatomic interference (40Ar16O). Separation of myoglobin from other iron-containing compounds was facilitated by use of a gel filtration column (TSK Gel G2000SW) and Tris buffer (pH 7.2). The chromatographic column was coupled directly to the nebulizer of the ICP-MS instrument by a short piece of PEEK tubing. To ensure sufficient quality control throughout the study, a raw beefsteak sample was developed as an in-house reference material. The concentration of the heme-iron-containing protein myoglobin in this sample was determined by the developed method and independently by a conventional spectrophotometric method. The agreement between the 2 analytical techniques was very good. The detection limit (3 times the signal/noise ratio for a blank) of the reported method for myoglobin was 0.85 ng Fe/L.


Assuntos
Análise de Alimentos , Ferro/análise , Mioglobina/análise , Animais , Calibragem , Bovinos , Cromatografia Líquida , Peixes , Indicadores e Reagentes , Espectrometria de Massas , Carne/análise , Ferroproteínas não Heme/análise , Controle de Qualidade , Padrões de Referência , Ovinos , Frutos do Mar/análise
16.
Ann Clin Biochem ; 51(Pt 3): 386-91, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24081185

RESUMO

BACKGROUND: Measurement of selenium in serum is an important clinical biomarker of nutritional status. The presence of gadolinium (Gd) in samples following administration of the contrast agents used for magnetic resonance imaging (MRI) results in a significant positive bias when using quadrupole inductively coupled plasma mass spectrometry (Q-ICP-MS). METHODS: Three instrumental set-ups were assessed: standard mode with no collision gas and collision cell mode with either a hydrogen:helium mixture or hydrogen. The effect of Gd on the selenium (Se) signal was assessed using external quality assurance (EQA) specimens and internal quality control (IQC) materials, both unspiked and spiked with Gd. Serum previously shown to contain high concentrations of Gd-containing contrast agents were also analysed. RESULTS: Recoveries of Se in the spiked compared to the unspiked samples were: between 500% and 1300% using standard mode; 100% and 29,000% using collision cell mode with hydrogen:helium mixture; and between 99% and 103% using hydrogen. The use of H2 in the collision cell provided accurate results, indicating that the charge exchange reaction (CER) of Gd(2+) with H2 removes this interference. Analysis of patient serum known to contain the Gd contrast agent using the method gave results within the selenium reference range (adults 0.89-1.65 µmol/L). The presence of Gd, as low as 0.2 mg/L, in serum samples causes a positive interference on the measurement of Se by ICP-MS. CONCLUSIONS: Using a CER mode with pure H2 in the collision cell it was possible to fully remove the interference due to Gd(2+) from the signal for Se.


Assuntos
Análise Química do Sangue/métodos , Gadolínio/sangue , Espectrometria de Massas/métodos , Selênio/sangue , Artefatos , Gadolínio/química , Hospitais , Humanos
17.
Ann Clin Biochem ; 48(Pt 2): 176-7, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21355013

RESUMO

Selenium is an important clinical biomarker of nutritional status; however, the occurrence of gadolinium in a patient's serum as a result of the contrast agents used during magnetic resonance imaging investigations, results in a significant positive bias in its measurement by inductively coupled plasma-quadrupole mass spectrometry.


Assuntos
Artefatos , Análise Química do Sangue/métodos , Gadolínio/sangue , Espectrometria de Massas/métodos , Selênio/sangue , Feminino , Humanos
19.
Chem Res Toxicol ; 20(8): 1177-82, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17636892

RESUMO

Cellular resistance, both intrinsic and acquired, poses a problem in the effectiveness of platinum-based chemotherapy. The cytotoxic activity of Pt-based chemotherapeutic agents is derived from their ability to react with cellular DNA. Oxaliplatin binds to the N7 position of the purine DNA bases, forming mainly intrastrand cross-links between either two adjacent guanines (GG), an adjacent adenine and guanine (AG), or two guanines separated by an unmodified nucleotide (GNG). We report the development of a liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method for measuring GG and AG intrastrand cross-links formed by oxaliplatin. The limits of detection for GG-oxPt and AG-oxPt were 23 and 19 adducts per 10 (8) nucleotides, respectively. We compare the formation and persistence of intrastrand cross-links between wild-type and glutathione transferase P null mice (GSTP null) treated with oxaliplatin. No significant difference was observed in the level of intrastrand cross-links formed by oxaliplatin between the mouse strains in liver, kidney, and lung DNA. Adduct levels were greatest in liver and lowest in lung tissue.


Assuntos
Antineoplásicos/farmacologia , Cromatografia Líquida/métodos , Reagentes de Ligações Cruzadas/metabolismo , DNA/análise , Compostos Organoplatínicos/toxicidade , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Animais , Antineoplásicos/uso terapêutico , Cisplatino/metabolismo , Cisplatino/farmacologia , Cisplatino/toxicidade , Reagentes de Ligações Cruzadas/química , DNA/metabolismo , Adutos de DNA/análise , Adutos de DNA/metabolismo , Camundongos , Camundongos Knockout , Compostos Organoplatínicos/metabolismo , Compostos Organoplatínicos/farmacologia , Oxaliplatina , Distribuição Tecidual
20.
Toxicol Appl Pharmacol ; 216(1): 122-30, 2006 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-16762385

RESUMO

Very little is known about arsenic (As) metabolism in healthy populations that are not exposed to high concentrations of As in their food or water. Here we present a study with healthy volunteers from three different ethnic groups, residing in Leicester, UK, which reveals statistically significant differences in the levels of total As in urine and fingernail samples. Urine (n = 63), hair (n = 36) and fingernail (n = 36) samples from Asians, Somali Black-Africans and Whites were analysed using inductively coupled plasma mass spectrometry (ICP-MS) and graphite furnace atomic absorption spectroscopy (GF-AAS). The results clearly show that the total concentrations of As in urine and fingernail samples of a Somali Black-African population (urine 7.2 microg/g creatinine; fingernails 723.1 microg/kg) are significantly (P < 0.05) different from the Asian (urine 24.5 microg/g creatinine; fingernails 153.9 microg/kg) and White groups (urine 20.9 microg/g creatinine; fingernails 177.0 microg/kg). The chemical speciation of As in the urine of the three groups was also measured using high performance liquid chromatography coupled to ICP-MS. This showed that the proportion of the total urinary As present as dimethylarsenate (DMA) was higher for the Somali Black-African group (50%) compared to the Asians (16%) and Whites (22%). However, there was no significant difference (P > 0.05) in the level of As in the hair samples from these three groups; Somali Black-Africans (116.0 microg/kg), Asians (117.4 microg/kg) and Whites (141.2 microg/kg). Significantly different levels of total As in fingernail and urine and a higher percentage of urinary DMA in the Somali Black-Africans are suggestive of a different pattern of As metabolism in this ethnic group.


Assuntos
Arsênio/metabolismo , Arsenicais/metabolismo , Cabelo/metabolismo , Unhas/metabolismo , Adulto , Arsênio/urina , Arsenicais/urina , Ásia Ocidental/etnologia , Cromatografia Líquida de Alta Pressão/métodos , Creatinina/urina , Feminino , Humanos , Masculino , Somália/etnologia , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrofotometria Atômica/métodos , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA