Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 182
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Arch Orthop Trauma Surg ; 144(5): 2381-2389, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38554208

RESUMO

INTRODUCTION: This study aimed to investigate the accuracy of cup position and assess the changes in pelvic tilt during primary total hip arthroplasty (THA) in the lateral decubitus position using a new computed tomography (CT)-based navigation system with augmented reality (AR) technology. MATERIALS AND METHODS: There were 37 cementless THAs performed using a CT-based navigation system with AR technology in the lateral decubitus position and 63 cementless THAs performed using manual implant techniques in the lateral decubitus position in this retrospective study. Postoperative cup radiographic inclination and anteversion were measured using postoperative CT, and the proportion of hips within Lewinnek's safe zone was analyzed and compared between the two groups. The mean absolute values of navigation error were assessed. Intraoperative pelvic tilt angles were also recorded using navigation system. RESULTS: The percentage of cups inside Lewinnek's safe zone was 100% in the navigation group and 35% in the control group (p < 0.001). The mean absolute values of navigation error in inclination and anteversion were 2.9° ± 2.1° and 3.3° ± 2.4°, respectively. The mean abduction angle of the pelvis was 5.1° ± 4.8° after placing the patients in the lateral decubitus position and 4.1° ± 6.0° after cup placement. The mean posterior tilt angle was 6.8° ± 5.1° after placing the patients in the lateral decubitus position and 9.3° ± 5.9° after cup placement. The mean internal rotation angle was 14.8° ± 7.4° after cup placement. There were no correlations between the navigation error in inclination or anteversion and the absolute values of changes of the pelvic tilt angle at any phase. CONCLUSIONS: Although progressive pelvic motion occurred in THA in the lateral decubitus position, especially during cup placement, the CT-based navigation system with AR technology improved cup placement accuracy.


Assuntos
Artroplastia de Quadril , Posicionamento do Paciente , Tomografia Computadorizada por Raios X , Humanos , Artroplastia de Quadril/métodos , Artroplastia de Quadril/instrumentação , Feminino , Masculino , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Posicionamento do Paciente/métodos , Prótese de Quadril , Realidade Aumentada , Sistemas de Navegação Cirúrgica , Cirurgia Assistida por Computador/métodos , Pelve/diagnóstico por imagem , Ossos Pélvicos/diagnóstico por imagem , Ossos Pélvicos/cirurgia
2.
BMC Musculoskelet Disord ; 24(1): 872, 2023 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-37946152

RESUMO

BACKGROUND: The aim of this study was examining the accuracy of accelerometer-based portable navigation systems (HipAlign) when measuring leg length changes using two-dimensional (2D) and three-dimensional (3D) methods. METHODS: Inclusion criteria were patients ≥ 20 years old with symptomatic hip disease who underwent primary total hip arthroplasty (THA) in the supine position using HipAlign between June 2019 and April 2020. The exclusion criteria were patients who underwent THA via a posterior approach. We examined correlations between the leg length change measurement with HipAlign and either 2D or 3D measurement. We performed a multivariate analysis to determine which factors may have influenced the absolute error results. RESULTS: This study included 34 patients. The absolute error in leg length change between the HipAlign and 3D measurement (4.0 mm) was greater than the HipAlign and 2D measurement (1.7 mm). There were positive correlations between leg length change with HipAlign and 2D and 3D measurements. Male patients had larger errors with 2D measurement. No significant factors were identified for 3D measurement. CONCLUSION: HipAlign provided acceptable measurement accuracy for leg length changes.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Cirurgia Assistida por Computador , Humanos , Masculino , Adulto Jovem , Adulto , Artroplastia de Quadril/métodos , Perna (Membro) , Cirurgia Assistida por Computador/métodos , Acelerometria/métodos
3.
J Artif Organs ; 2023 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-37707635

RESUMO

PURPOSE: Hemi-resurfacing arthroplasty (Hemi) and metal-on-metal hip resurfacing arthroplasty (HR) were proposed as alternatives to conventional total hip arthroplasty (THA) for patients with osteonecrosis of the femoral head (ONFH). Long-term results were evaluated. METHODS: Twenty-three hips with ONFH were treated, using Hemi in 12 and HR in 11. Mean follow-up was 15 years in the Hemi group and 10 years in the HR group. Long-term outcomes were reviewed retrospectively. RESULTS: In the Hemi group, 8 hips showed acetabular protrusion and were revised to THA. One of the 8 hips showed femoral loosening. In the HR group, pseudotumor was detected in 4 hips (36%), and 1 hip was revised due to symptomatic pseudotumor. No evidence of any femoral or acetabular loosening was seen in the HR group. Ten-year survival rates were 64.2% and 90.9% in the Hemi and HR groups, respectively. Survival rate in the Hemi group dropped to 22.9% at 15 years. CONCLUSIONS: Long-term results of Hemi for patients with ONFH were very poor, and Hemi should not continue to be used. Although HR had a concern of pseudotumor, it could offer attractive indications for 10 years.

4.
Knee Surg Sports Traumatol Arthrosc ; 31(2): 399-405, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34738158

RESUMO

PURPOSE: The primary aim was to evaluate the accuracy of navigation in opening wedge high tibial osteotomy (HTO). The secondary aim was to examine mid-term outcomes after HTO. METHODS: Inclusion criteria were patients with medial compartment knee osteoarthritis who underwent computer-assisted HTOs. Mechanical axis (MA), percentage MA (%MA), and change in posterior tibial slope (ΔPTS) were displayed on the navigation screen. Radiographic examinations included hip-knee-ankle (HKA) angle, medial proximal tibial angle (MPTA), joint line convergence angle (JLCA), and PTS. Preoperative and 5 weeks postoperative standing radiographs of the whole lower extremity and knee were used. Clinical evaluations were performed using American Knee Society knee score and function score both preoperatively and at last follow-up. Radiographic evaluations were performed by orthopedic surgeons. Intraoperative navigation after osteotomy and postoperative standing radiograph were compared. MA (HKA), %MA, and ΔPTS were compared. Outliers were defined as > 3° in MA, > 10% in %MA, and > 10° in ΔPTS. Outlier and non-outlier groups were compared. The rate of conversion to arthroplasty was examined. RESULTS: This study involved 38 patients (44 knees) and last follow-up was at a mean of 5 years (range, 1-9 years). Mean American Knee Society knee score and function score improved significantly from 59 to 69 preoperatively to 95 and 85 at last follow-up, respectively. Absolute values of mean errors for MA, %MA, and ΔPTS were 2.1°, 9.3%, 1.2°, respectively. Outlier rates were 18% in MA, 39% in %MA, and 5% in ΔPTS. No significant factors were found in MA and ΔPTS. In %MA, preoperative JLCA was significantly higher in the outlier group compared to the non-outlier group. No knees underwent conversion to total knee arthroplasty. No differences in outcomes were found between outlier and non-outlier groups. CONCLUSION: Although rates of outlier values in computer-assisted opening wedge HTO were high, mid-term outcomes were excellent. LEVEL OF EVIDENCE: IV.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Osteotomia , Computadores , Estudos Retrospectivos
5.
Mod Rheumatol ; 33(6): 1183-1189, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36264180

RESUMO

OBJECTIVES: The objective of the study is to evaluate the relationship between clinical results following posterior-stabilized total knee arthroplasty (TKA) and intraoperative kinematic pattern determined from navigation. METHODS: Participants were patients with knee osteoarthritis and varus deformity who underwent primary posterior-stabilized TKA. Preoperative and post-implantation kinematic data were recorded, and all kinematic patterns were divided into two types: medial pivot (MP) or non-MP. Knees with MP and non-MP patterns after implantation were compared in terms of postoperative flexion angle, pain, patient satisfaction, expectations, and activity using the new Knee Society Score 2011 at 1 year postoperatively. RESULTS: This study involved 55 patients (12 men, 43 women) with a mean age of 73.1 years and mean body mass index of 26.5 kg/m2. Preoperative kinematic measurements showed MP in 23 knees and non-MP in 32 knees. After implantation, navigation showed MP in 25 knees and non-MP in 30 knees. No significant differences were found between kinematic patterns preoperatively and after implantation. Postoperative flexion angle, pain, patient satisfaction, expectations, and activity using Knee Society Score 2011 showed no differences between MP and non-MP knees. CONCLUSION: Intraoperative knee kinematics as measured by navigation could not predict postoperative outcomes of TKA.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Masculino , Humanos , Feminino , Idoso , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Articulação do Joelho/cirurgia , Joelho , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular , Dor
6.
BMC Musculoskelet Disord ; 23(1): 537, 2022 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-35658945

RESUMO

BACKGROUND: This study aimed to determine the accuracy of acetabular cup insertion using a novel accelerometer-based navigation system in total hip arthroplasty (THA). METHODS: A single-surgeon study was conducted in which 62 prospective patients with navigation and 42 retrospective patients without navigation in a supine position were compared. Absolute values for errors of radiographic inclination and anteversion were calculated. Navigation error was also calculated. Factors that affected absolute value of navigation error in cup alignment were determined. RESULTS: In the navigation group, mean absolute errors for radiographic inclination and anteversion were 4.1° and 4.3°, respectively. In the control group, mean absolute errors were 6.6° in inclination (p < 0.01) and 5.9° in anteversion (p = 0.04). Mean absolute values of navigation error were 2.8° in inclination and 2.8°in anteversion. Factors affecting navigation errors were not found. CONCLUSION: This novel accelerometer-based navigation system significantly increased the accuracy of cup placement during THA in the supine position.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Cirurgia Assistida por Computador , Acelerometria , Acetábulo/cirurgia , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Decúbito Dorsal
7.
J Orthop Sci ; 27(5): 1096-1099, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34229907

RESUMO

BACKGROUNDS: Preoperative widespread pain sensitization or pain catastrophizing could be associated with chronic pain after total knee arthroplasty (TKA). The aim of the present study was to examine the association between postoperative pain in patients undergoing TKA and preoperative factors, including patient characteristics and preoperative central sensitization as well as pain catastrophizing. METHODS: Preoperative TKA patients were evaluated using the Central Sensitization Inventory (CSI)-9 and Pain Catastrophizing Scale (PCS). Postoperative knee pain was evaluated using a numerical rating scale (NRS) 6 months after TKA. Statistical analyses were performed to assess the relationship between NRS 6 months after TKA and preoperative factors, including patient characteristics, CSI-9, and PCS. RESULTS: We enrolled 58 consecutive patients with osteoarthritis who underwent TKA. Using cutoff of 14, postoperative NRS was higher in the patients with ≥14 than the patients with <14 in CSI (p = 0.025). Postoperative NRS was higher in the patients with ≥30 than the patients with <30 in PCS (p = 0.043). Preoperative PCS was a significant risk factor of postoperative pain using a multivariate analysis. CONCLUSIONS: Surgeon should recognize preoperative PCS could affect postoperative pain 6 months after TKA.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Artroplastia do Joelho/efeitos adversos , Catastrofização , Humanos , Osteoartrite do Joelho/complicações , Osteoartrite do Joelho/cirurgia , Medição da Dor , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/etiologia , Estudos Prospectivos , Resultado do Tratamento
8.
J Environ Manage ; 321: 115861, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36050136

RESUMO

Hydrogen sulfide (H2S) is known to have wide ranging toxicities not only as a gas but also as dissolved forms in aquatic environments. The diversity of aquatic organisms can be severely affected by hydrogen sulfide at very low concentrations, indicating the urgent necessity to develop an efficient method for removal of hydrogen sulfide in water. In this study, the removal capacity for hydrogen sulfide of our originally developed hydrotalcite-like compound composed of magnesium and iron (MF-HT) was investigated and its potential application for reduction of toxicity to aquatic organisms was evaluated. The MF-HT experimentally showed a high adsorption capacity of 146.5 mg/g with a fast adsorption equilibrium time of 45 min, both of which are top-class compared with those of other adsorbents previously reported. In fact, removal of hydrogen sulfide (1.2-152.5 mg/L) at an average rate of >97.6% was achieved in groundwater samples (n = 16) by the MF-HT within 60 min. The toxicities of groundwater, indicated by inhibition rate for microalgae (primary producers) and immobilization rate for crustaceans (secondary consumers), were reduced by 96.1% and 82.5% in 2-fold and 4-fold diluted groundwater, respectively, after treatment with the MF-HT for 60 min. These results indicate that MF-HT has an excellent safety record for aquatic organisms. After clarifying the adsorption mechanism, excellent reusability of MF-HT was also confirmed after regeneration using 1 M Na2CO3 solution. Considering the efficacy, speed, safety and cost of MF-HT, it could be a novel promising material for solving the problem of hydrogen sulfide pollution in the hydrosphere.


Assuntos
Sulfeto de Hidrogênio , Hidróxido de Alumínio , Organismos Aquáticos , Hidróxido de Magnésio
9.
Mod Rheumatol ; 32(2): 438-443, 2022 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-33910453

RESUMO

OBJECTIVES: The purpose of this study was to measure the indices of radiographic developmental dysplasia of the hip (DDH) in a cross-sectional study of an elderly Japanese population. METHODS: Hip radiographs of 427 informed, voluntary Japanese community-dwelling individuals (279 female and 148 male) aged 50-96 years-old were obtained from Miyagawa village in Japan through a health screening. The hip radiographs were measured by a custom-written, semi-automated MATLAB program. The center edge (CE) angle, acetabular roof obliquity (ARO), acetabular head index (AHI), and minimum joint space width (mJSW) were measured. We examined the associations between gender, side-of-hip, and age group on radiographic DDH and hip osteoarthritis (OA). RESULTS: The mean CE angle was 31.0°. The mean ARO was 5.8°. The mean AHI was 88.2%. The mean mJSW was 4.0 mm. Of the total population, 29.9% had DDH and 4.0% had hip OA. Of those who had hip OA, 41.2% were secondary OA, and 58.8% were primary OA. The relationship between DDH and OA was not significant. CONCLUSION: DDH is unlikely to be an important cause of hip OA in the present population-based study.


Assuntos
Luxação Congênita de Quadril , Luxação do Quadril , Osteoartrite do Quadril , Acetábulo , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Luxação Congênita de Quadril/complicações , Articulação do Quadril/diagnóstico por imagem , Humanos , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/epidemiologia , Osteoartrite do Quadril/etiologia , Prevalência , Estudos Retrospectivos
10.
J Artif Organs ; 24(1): 82-89, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32880017

RESUMO

The purpose of this study was to determine the accuracy of acetabular cup insertion during total hip arthroplasty (THA) in a supine position using an accelerometer-based portable navigation system. A single-surgeon study was conducted in which 62 prospective patients with navigation and 42 retrospective patients without navigation as historical controls were compared. The patients underwent THA via an anterolateral supine approach. The absolute values of errors of radiographic inclination and anteversion were calculated. The navigation error was also calculated. The factors that affected the absolute values of errors of cup alignment were determined. The mean absolute error of the postoperative CT measurement from the target angle for radiographic inclination was 3.8° in the navigation group and 6.6° in the control group (P < 0.001). The mean absolute error for anteversion was 3.3° in the navigation group and 5.9° in the control group (P < 0.001). The mean absolute values of navigation error were 3.7° ± 2.8° in inclination and 3.0° ± 2.6° in anteversion. Changes in the pelvic tilt angle among preoperative, intraoperative, and postoperative were the significant risk factors for the absolute values of navigation error of anteversion relative to the anterior pelvic plane. Other factors affecting the absolute values of errors in the navigation group were not found for radiographic inclination and anteversion. The portable navigation system significantly improved the accuracy of cup inclination and anteversion. Changes in the pelvic tilt were the risk factors for the error of anteversion relative to the anterior pelvic plane.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Prótese de Quadril , Sistemas de Navegação Cirúrgica/estatística & dados numéricos , Acelerometria , Idoso , Artroplastia de Quadril/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Postura , Estudos Prospectivos , Estudos Retrospectivos , Decúbito Dorsal , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X
11.
BMC Musculoskelet Disord ; 22(1): 1016, 2021 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-34863119

RESUMO

BACKGROUND: Intraoperative navigation systems have been shown to improve the accuracy of acetabular component insertion in total hip arthroplasty (THA). The purpose of this study was to investigate the accuracy of cup orientation in primary THA using an image-free navigation system. METHODS: A total of 107 consecutive cementless THAs using an image-free navigation system were performed from February 2017 to March 2020 (the navigation group). As a control group, 77 retrospective consecutive cases who underwent THAs with manual implant-techniques between February 2012 and April 2017 were included. Postoperative cup radiographic inclination and radiographic anteversion relative to the functional pelvic plane were assessed using a 3D-template system after computed tomography (CT) examination. RESULTS: The mean absolute errors of the postoperative measured angles from the target angles in inclination were 3.4° ± 3.0° in the navigation group and 8.4° ± 6.6° in the control group (p < 0.001). The mean absolute errors in anteversion were 5.1° ± 3.6° in the navigation group and 10.8° ± 6.5° in the control group (p < 0.001). The percentage of cups inside the Lewinnek safe zone was 93% in the navigation group and 44% in the control group (p < 0.001). The mean absolute values of navigation error were 3.3° ± 2.8° in inclination and 5.8° ± 4.9° in anteversion. Among the cases of osteoarthritis, the inclination error was significantly higher in Crowe group 2 to 4 than in Crowe group 1 (5.1° ± 3.5° and 3.0° ± 2.5°, respectively, p < 0.05). The percentage of hips with inclination error over 10° in Crowe group 2 to 4 was significantly higher than in Crowe group 1 (17 and 1%, respectively, p < 0.05). CONCLUSIONS: The image-free navigation system improved the accuracy of cup orientation. The accuracy of cup position was less in Crowe group 2 to 4 than in Crowe group 1.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Cirurgia Assistida por Computador , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Humanos , Estudos Retrospectivos
12.
BMC Musculoskelet Disord ; 22(1): 1021, 2021 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-34872557

RESUMO

BACKGROUND: Leg length discrepancy is one of the most common problems after total hip arthroplasty (THA). The aim of this study was to investigate the accuracy of image-free navigation in intraoperative leg length change (LLC) using evaluations from anteroposterior radiographs (2D measurement) and 3D bone models using CT data (3D measurement). METHODS: One hundred THAs with cementless cups and stems were performed using an image-free navigation system in our hospital. We evaluated the accuracy of image-free navigation based on LLC from 2D and 3D measurements. Furthermore, we also investigated error in absolute value and correlations between 2D and 3D measurements in LLC. RESULTS: The accuracy of image-free navigation based on 2D measurement was 94% within 5 mm and 76% within 3 mm. The accuracy of image-free navigation based on 3D measurement was 92% within 5 mm and 81% within 3 mm. The error in absolute value in LLC between 2D and 3D measurements was 1.7 ± 1.4 mm (range, 0 to 6 mm). A strong correlation was observed between 2D and 3D measurements in the LLC. CONCLUSIONS: In the present study, good accuracy of image-free navigation in intraoperative LLC was confirmed for both evaluation methods from 2D and 3D measurements. In addition, the error in absolute value in the LLC between 2D and 3D measurements was very small, and we observed a strong correlation between 2D and 3D measurements. Based on these results, evaluation of LLC from radiographs was considered sufficient if radiographs can be taken accurately.


Assuntos
Artroplastia de Quadril , Cirurgia Assistida por Computador , Artroplastia de Quadril/efeitos adversos , Humanos , Perna (Membro) , Desigualdade de Membros Inferiores/diagnóstico por imagem , Desigualdade de Membros Inferiores/etiologia , Desigualdade de Membros Inferiores/cirurgia
13.
J Arthroplasty ; 36(2): 647-652, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32950339

RESUMO

BACKGROUND: The clinical and radiographic results of cementless total hip arthroplasty using a 32-mm cobalt-chromium head on remelted highly cross-linked polyethylene (HXLPE) and a tapered, fiber metal proximally coated femoral stem were evaluated at a mean follow-up of 12 years. METHODS: A total of 57 cementless total hip arthroplasties using remelted HXLPE combined with a 32-mm cobalt-chromium head, and a tapered, fiber metal proximally coated femoral stem were performed from October 2004 to December 2006. Clinical evaluation was performed using the Merle d'Aubigné and Postel scoring system. Standardized anteroposterior and lateral radiographs of the pelvis and femur without weight-bearing were analyzed. Radiographic measurements of two-dimensional femoral head penetration into the polyethylene were performed with a computerized method. The steady-state wear rates were measured based on the radiographs from the first year after surgery to the final follow-up. RESULTS: The mean Merle d'Aubigné and Postel score improved significantly from 10.7 points preoperatively to 15.6 postoperatively (P < .001). No osteolysis was found around the implant. Stem fixation in all cases showed stable bone ingrowth. Third-degree stress shielding was found in 46% of all stems. The total head penetration rate was 0.05 mm/y, and the steady-state wear rate was 0.01 mm/y. The Kaplan-Meier survivorship with the end point of revision was 95% (95% confidence interval, 85%-98%) at 12 years. CONCLUSION: A 32-mm cobalt-chromium head on remelted HXLPE demonstrated low wear properties, and a tapered, fiber metal proximally coated femoral stem showed good results at long-term follow-up.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Cromo , Cobalto , Fêmur , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Polietileno , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos
14.
Int Orthop ; 45(7): 1727-1733, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33825004

RESUMO

PURPOSE: The fully porous long stem could be used for diaphyseal locking and achieve bypass fixation in revision total hip arthroplasty (THA). This study evaluated long-term results for fully porous long stems made of titanium alloy in revision THA. METHODS: Between 2003 and 2010, 45 consecutive femoral revisions were performed using fully porous long stems. Thirty-eight hips had complete clinical and radiographic data for a mean of 13.8 years (range, 10-16.7 years). Femoral bone loss was Paprosky type II in 14 hips, type IIIA in 18 hips, and type IIIB in six hips. Clinical results were analyzed using the Merle d'Aubigné and Postel scoring system. Femoral stress shielding was graded. Radiological loosening of the femoral component was evaluated. Kaplan-Meier survival analysis was performed with revision for any reason as the end-point. RESULTS: Mean Merle d'Aubigné and Postel score improved significantly from 10.7 before revision to 14.5 at latest follow-up (p < 0.001). Third-degree stress shielding was found in seven hips, and fourth degree in 11 hips. Radiological femoral loosening occurred in one hip, which was revised. Another hip was revised for stem fracture. Kaplan-Meier cumulative survival rate was 94.7% at both ten and 15 years. CONCLUSION: Although stress shielding is a concern with fully porous stems, this stem was useful in revision THA and provided satisfactory long-term results in hips with Paprosky types II, IIIA, and IIIB.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Seguimentos , Humanos , Porosidade , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Titânio , Resultado do Tratamento
15.
Mod Rheumatol ; 31(5): 1073-1077, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33428481

RESUMO

OBJECTIVES: Antibiotic-impregnated hydroxyapatite (HA) is an emerging drug delivery system for the treatment of periprosthetic joint infection (PJI) of the knee. The aim of this study was to evaluate the clinical results of this treatment in patients with PJI following total knee arthroplasty (TKA). METHODS: Participants comprised 14 consecutive patients with PJI of the knee who were scheduled to undergo two-stage knee revision. In the first stage, all components were removed with thorough debridement, and antibiotic-impregnated HA was inserted in the bone and joint space. In the second stage, revision TKA was performed after the eradication of infection. The mean period from the removal of all components and treatment with antibiotic-impregnated HA to revision TKA was 3.4 months. Clinical and radiographic evaluations were performed after a mean follow-up of 6.1 years following revision TKA. Predictors of reinfection were evaluated. RESULTS: Eleven patients had no recurrent infection, whereas 3 patients showed recurrent infection. Knee Society knee score and function score, as well as flexion angles, improved significantly postoperatively. No knees showed osteolysis or loosening after revision TKA. The present study identified no predictors of reinfection. CONCLUSION: Antibiotic-impregnated HA could be effective in treating knee PJI.


Assuntos
Artroplastia do Joelho , Antibacterianos/uso terapêutico , Artroplastia do Joelho/efeitos adversos , Durapatita , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Infecções Relacionadas à Prótese/tratamento farmacológico , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
16.
Mod Rheumatol ; 31(4): 899-903, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32857673

RESUMO

OBJECTIVES: The prevalence of femoroacetabular impingement (FAI) was evaluated using a Japanese population-based cohort of participants aged ≥50 years. METHODS: Radiographs (n = 854) of bilateral hips of 427 participants (279 women, 148 men) were used for the analysis. The prevalence of cam type, pincer type, and mixed type FAI as well as osteoarthritis was evaluated. The association of FAI and osteoarthritis (OA), and pain were also evaluated. RESULTS: The prevalence of cam type and pincer type FAI were 4.2% and 20.3%, respectively. Mixed type FAI was 0.7%. OA was found in 4.0% of patients, and 17 hips (2.0%) with any FAI also had OA. A significant relationship between cam type FAI and OA was found, whereas no significant relationship between pincer type FAI and OA was seen. Sixty (7.0%) of all the hips were reported to be painful, and 14 of those painful hips (1.6%) had FAI. No significant relationship between FAI and hip pain was found. CONCLUSION: We reported the first population-based prevalence of FAI in Japan. Radiological FAI was common, and pincer type was more common than cam type. The anatomical abnormalities associated with FAI, although often asymptomatic, are risk factors for OA.


Assuntos
Artralgia/epidemiologia , Impacto Femoroacetabular/epidemiologia , Articulação do Quadril/patologia , Osteoartrite do Quadril/epidemiologia , Adulto , Idoso , Artralgia/diagnóstico por imagem , Artralgia/patologia , Estudos de Coortes , Feminino , Impacto Femoroacetabular/diagnóstico por imagem , Impacto Femoroacetabular/patologia , Humanos , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/patologia , Dor , Prevalência , Radiografia , Fatores de Risco
17.
Mod Rheumatol ; 31(5): 1045-1049, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33153348

RESUMO

OBJECTIVES: Zirconia ceramic was introduced for femoral heads because of its mechanical strength and fracture toughness. Highly cross-linked polyethylene has been shown to achieve wear reduction compared to conventional polyethylene. The purpose of this study was to investigate the long-term results of cementless total hip arthroplasty with zirconia femoral heads on highly cross-linked polyethylene. METHODS: Radiographic measurements of two-dimensional femoral head penetration into the polyethylene were performed with a computerized method (PolyWare) in 93 hips at a mean follow-up of 13 years. The steady-state wear rates were measured based on the radiographs from the first year after surgery to the final follow-up. RESULTS: The mean Merle d'Aubigné and Postel score had improved significantly from 10.9 points preoperatively to 15.3 postoperatively (p < 0.001). Osteolysis was not found around the implant, and no zirconia heads had fractures. The total head penetration rate was 0.04 mm/year, and the steady-state wear rate was 0.02 mm/year. Kaplan-Meier survivorship with the endpoint of revision was 97% (95% confidence interval [CI], 92% to 99%) at 10 years. CONCLUSION: Zirconia on highly cross-linked polyethylene demonstrated extremely low wear properties at long-term follow-up.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Seguimentos , Humanos , Polietileno , Desenho de Prótese , Falha de Prótese , Zircônio
18.
Biol Pharm Bull ; 43(2): 266-271, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32009116

RESUMO

Bleeding is a life-threating side effect of thromboprophylaxis with fondaparinux sodium (FPX) injection. The purpose of this retrospective study was to assess the risk factor for bleeding-related event following thromboprophylaxis with FPX after total knee arthroplasty (TKA) or total hip arthroplasty (THA). Adult patients undergoing TKA or THA at a single university hospital were administered FPX for thromboprophylaxis by subcutaneous injection of 1.5 or 2.5 mg per day. The risk factor for bleeding-related event was identified by propensity score-adjusted multivariate logistic analysis, and survival analysis was performed retrospectively in consideration of the identified risk factors. Two hundred and twenty-six patients who underwent TKA (n = 62) or THA (n = 164) were enrolled. Anaemia on postoperative day (POD) 1 was identified as a risk factor for bleeding-related event (odds ratio: 3.75, 95% confidence interval: 1.02-24.5, p = 0.04). Eighty of 226 patients were selected using a propensity score matching and patients with anaemia on POD1 in this population had a significantly higher incidence of bleeding-related event than those without anaemia (p = 0.0016, Ghen-Breslow-Wilcoxon test; p = 0.0015, log-rank test). These results suggest that anaemia on POD1 is an independent risk factor for bleeding-related event following thromboprophylaxis with FPX after TKA or THA.


Assuntos
Anemia/complicações , Artroplastia de Quadril , Artroplastia do Joelho , Fondaparinux/efeitos adversos , Hemorragia Pós-Operatória/etiologia , Tromboembolia Venosa/prevenção & controle , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Hemorragia Pós-Operatória/epidemiologia
19.
J Orthop Sci ; 25(2): 324-330, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30975540

RESUMO

BACKGROUND: The effects of tenascin-C (TNC) on cartilage repair were examined in cartilage defect model mice. An in vitro study was also performed to determine the mechanism of cartilage repair with TNC. METHODS: Full-thickness osteochondral defects were filled with TNC (group A: 100 µg/ml, group B: 10 µg/ml, group C: empty). Mice were sacrificed at 1, 2, 3, and 6 weeks postoperatively. Cartilage repair was histologically evaluated using the modified WAKITANI score. Chondrocytes were isolated and cultured, and they were treated with TNC. The expressions of various mRNAs including TNC, inflammatory cytokines, and anabolic and catabolic factors for cartilage were compared by real-time polymerase chain reaction. RESULTS: The defects in group A were covered with hyaline-like cartilage after 3 weeks. Average modified WAKITANI scores were significantly better in group A than in groups B and C at 3 and 6 weeks. TNC upregulated the expressions of endogenous TNC, inflammatory cytokines, and anabolic and catabolic factors for cartilage. TNC downregulated the expression of a disintegrin and metalloproteinase with thrombospondin motifs (ADAMTS) 5. CONCLUSIONS: Intra-articular injection of full-length TNC repaired cartilage in murine models of full-thickness osteochondral defects. TNC upregulated the expression of ADAMTS4, but downregulated the expression of ADAMTS5 that contributed to cartilage degradation.


Assuntos
Doenças das Cartilagens/tratamento farmacológico , Cartilagem Articular/efeitos dos fármacos , Articulação do Joelho/efeitos dos fármacos , Tenascina/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Animais , Modelos Animais de Doenças , Humanos , Injeções Intra-Articulares , Camundongos , Camundongos Endogâmicos BALB C , Pessoa de Meia-Idade
20.
Mod Rheumatol ; 30(4): 765-772, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31339809

RESUMO

Objectives: Rebamipide is a protective drug used for gastric mucosal injuries, and it also exerts protective effects for a variety of other tissues. In this study, murine post-traumatic (PT) osteoarthritis (OA) models in vivo and human OA chondrocytes in vitro were used to examine the effects of rebamipide on articular cartilage degeneration.Methods: Male BALB/c mice were used. The knee ligaments were transected in both knees. Mice were injected with rebamipide into the knee joint every week. Human chondrocytes were stimulated with IL-1ß, then treated with or without rebamipide. The levels of mRNA expression of COL2A, IL-1ß, TNFα, NF-κB, MMP3, MMP13, ADAMTS5, TIMP3, FGF2, and TGFß were estimated using real-time PCR.Results: Histological scores were significantly better in the rebamipide 1 mg/mL and 10 mg/mL groups than in the control group. Rebamipide up-regulated the mRNA expressions of COL2A, TIMP3, TGFß, and FGF2 in chondrocytes and down-regulated IL-1ß, TNFα, NF-κB, MMP3, MMP13, and ADAMTS5.Conclusion: Intra-articular injection of rebamipide prevents articular cartilage degeneration for 6 weeks in murine models of OA in vivo. Rebamipide down-regulates inflammatory cytokines and catabolic factors and up-regulates anabolic factors in human chondrocytes in vitro. Rebamipide could be an important treatment for prevention of articular cartilage degeneration.


Assuntos
Alanina/análogos & derivados , Antioxidantes/uso terapêutico , Cartilagem Articular/efeitos dos fármacos , Osteoartrite/tratamento farmacológico , Quinolonas/uso terapêutico , Alanina/administração & dosagem , Alanina/farmacologia , Alanina/uso terapêutico , Animais , Antioxidantes/administração & dosagem , Antioxidantes/farmacologia , Cartilagem Articular/metabolismo , Injeções Intra-Articulares , Interleucina-1beta/genética , Interleucina-1beta/metabolismo , Masculino , Metaloproteinase 13 da Matriz/genética , Metaloproteinase 13 da Matriz/metabolismo , Camundongos , NF-kappa B/genética , NF-kappa B/metabolismo , Quinolonas/administração & dosagem , Quinolonas/farmacologia , Fator de Necrose Tumoral alfa/genética , Fator de Necrose Tumoral alfa/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA