Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Retina ; 44(7): 1171-1179, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38437847

RESUMO

PURPOSE: To examine postoperative outcomes of internal limiting membrane peeling (ILMP) versus flap (ILMF) in the closure of full-thickness macular holes. METHODS: Retrospective chart review of patients who underwent pars plana vitrectomy and gas tamponade with ILMP or ILMF to close full-thickness macular hole at the Atrium Health Wake Forest Baptist from January 2012 to October 2022 with at least 3 months follow-up. Main outcome measures were type 1 primary full-thickness macular hole closure and postoperative best-corrected visual acuity in mean logMAR. RESULTS: One hundred thirty and 30 eyes underwent ILMP and ILMF, respectively. There were no significant differences in baseline characteristics between the groups. Ninety-six percent of ILMP eyes and 90% of ILMF eyes achieved primary hole closure ( P = 0.29). Among all eyes with primary hole closure, best-corrected visual acuity at 1 year was not different between the groups, but when stratified by lens status, it was superior in the ILMP versus ILMF group in pseudophakic eyes: the estimated least-squares mean best-corrected visual acuity (Snellen equivalent) (95% confidence interval) was 0.42 (20/50) (0.34, 0.49) in the ILMP group and 0.71 (20/100) (0.50, 0.92) in the ILMF group. CONCLUSION: Internal limiting membrane peeling and ILMF techniques yielded similarly high full-thickness macular hole closure rates. In pseudophakic eyes with primary hole closure, ILMF eyes had worse best-corrected visual acuity at 1 year.


Assuntos
Membrana Basal , Tamponamento Interno , Perfurações Retinianas , Retalhos Cirúrgicos , Tomografia de Coerência Óptica , Acuidade Visual , Vitrectomia , Humanos , Perfurações Retinianas/cirurgia , Perfurações Retinianas/fisiopatologia , Estudos Retrospectivos , Acuidade Visual/fisiologia , Vitrectomia/métodos , Masculino , Feminino , Idoso , Membrana Basal/cirurgia , Tamponamento Interno/métodos , Pessoa de Meia-Idade , Seguimentos , Resultado do Tratamento , Membrana Epirretiniana/cirurgia , Membrana Epirretiniana/fisiopatologia
2.
J Stroke Cerebrovasc Dis ; 30(2): 105531, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33310593

RESUMO

OBJECTIVES: Acute central retinal artery occlusion (CRAO) is an ophthalmologic emergency that often results in permanent vision loss. Over 25% are associated with acute cerebral ischemia. In the absence of existing Level I treatment options, this study aims to examine institutional practice patterns and review the literature to develop a formalized approach to the treatment of CRAO in the era of ischemic stroke protocols. MATERIALS AND METHODS: This is a retrospective review of institutional practices in the workup and treatment of patients diagnosed with acute non-arteritic (NA) CRAO at a single center from January 2017 to August 2020. RESULTS: Of 91 patients managed for acute NA-CRAO, 62.6% were male and average age was 66.4 years. Only 20.9% of patients presented within 4 h of symptom onset. 12.1% of patients had evidence of acute stroke on MRI, and 27.5% had ipsilateral internal carotid artery stenosis >50%. Half (52.7%) did not receive any acute treatment for CRAO, excluding antiplatelet/anticoagulation. 48.5% of patients undergoing acute medical treatment had improved visual acuity compared to 29.4% without treatment (p=0.14). CONCLUSIONS: There is a lack of clear protocol for the management of NA-CRAO. While not reaching statistical significance, our experience mirrors the literature with patients undergoing medical treatment demonstrating improved visual acuity over those without treatment. Given the presence of acute ischemic stroke, carotid disease, and/or stroke risk factors in over 25% of patients with CRAO, multidisciplinary involvement and modern stroke algorithms should be considered for this disease.


Assuntos
Estenose das Carótidas/terapia , AVC Isquêmico/terapia , Oclusão da Artéria Retiniana/terapia , Visão Ocular , Idoso , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/epidemiologia , Estenose das Carótidas/fisiopatologia , Tomada de Decisão Clínica , Feminino , Humanos , AVC Isquêmico/diagnóstico por imagem , AVC Isquêmico/epidemiologia , AVC Isquêmico/fisiopatologia , Masculino , Recuperação de Função Fisiológica , Oclusão da Artéria Retiniana/diagnóstico por imagem , Oclusão da Artéria Retiniana/epidemiologia , Oclusão da Artéria Retiniana/fisiopatologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Resultado do Tratamento
3.
Int J Retina Vitreous ; 8(1): 64, 2022 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-36089603

RESUMO

BACKGROUND: Methods of sclerotomy closure following a vitrectomy, including the use of sutures, have been associated with complications such as inflammation, foreign body sensation, and infection. Here, we test an innovative approach to scleral wound closure following pars plana vitrectomy that involves plugging the wound. We investigated several materials with the intent of using products that were either already approved by the FDA for other types of procedures or were biocompatible patient-derived materials. METHODS: We examined whether scleral wounds could be sealed by a clot or internal "plug" rather than a suture or an external adhesive. We tested patient-derived materials (platelet-rich plasma (PRP) and whole blood) as well as polyethylene glycol (PEG) sealant. Whole blood and PRP were prevented from clotting prematurely using sodium citrate, and were clotted for the study with thrombin. Polyethylene glycol (PEG) sealant was prepared according to manufacturer's recommendations. We used fresh-frozen cadaveric porcine eyes. We tested several methods to form plugs using the above materials, as well as various methods to deliver the plugs into the sclerotomy incisions. We used a novel technique of manual vitrectomy. Successfully generated and implanted clots were tested for efficacy with the Seidel test. RESULTS: Polyethylene glycol (PEG) sealant fractured during our attempts at molding and inserting the plug. In contrast, both whole blood and PRP yielded successful plugs for insertion. We molded a whole blood clot plug by allowing it to clot inside a 20-gauge angiocath catheter and we successfully delivered it through a 23G trocar. At baseline, no wound leakage was apparent. However, the whole blood clot dislodged during the Seidel test. We successfully molded and delivered a PRP clot plug using a tapered 2-20 µl pipette tip, using MAXGrip Forceps to push it through into the wound. No scleral wound leakage was noted at our baseline physiologic infusion pressure. Furthermore, the PRP clot plug prevented scleral wound leakage up to a pressure of 60 mmHg and was confirmed with the Seidel test. CONCLUSION: Our findings suggest that insertion of a clot plug made from either whole blood or PRP may be an effective strategy for scleral wound closure following pars plana vitrectomy. Further testing in preclinical models is warranted to further refine the materials and methods, since this appears to have the potential to improve the closure of the scleral wounds after pars plana vitrectomy.

4.
Am J Ophthalmol Case Rep ; 16: 100529, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31453411

RESUMO

PURPOSE: Differentiating idiopathic sclerosing orbital inflammation from orbital inflammation secondary to neoplasia may be challenging, as both processes can present similarly. Neoplasms in the orbit may induce inflammation with accompanying fibrosis. Limited sections of histopathological specimens may demonstrate nonspecific inflammation and lead to an inaccurate diagnosis. OBSERVATIONS: The authors present a case of infiltrating adenocarcinoma of the orbit with mucinous features which was misdiagnosed as idiopathic sclerosing orbital inflammation due to three separate benign biopsy specimens. CONCLUSIONS AND IMPORTANCE: The ophthalmologist must remain suspicious of malignancy in cases of suspected idiopathic orbital inflammation with an atypical clinical course, regardless of apparently benign biopsy results.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA