Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Radiol Case Rep ; 9(5): 7-13, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-26622928

RESUMO

We report a case of a pregnant 21-year-old woman with pulmonary tuberculosis in which magnetic resonance imaging of the lung was used to assess the extent and characteristics of the pathological changes. Although the lung has been mostly ignored in magnetic resonance imaging for many decades, today technical development enables detailed examinations of the lung. The technique is now entering the clinical arena and its indications are increasing. Magnetic resonance imaging of the lung is not only an alternative method without radiation exposure, it can provide additional information in pulmonary imaging compared to other modalities including computed tomography. We describe a successful application of magnetic resonance imaging of the lung and the imaging appearance of post-primary tuberculosis. This case report indicates that magnetic resonance imaging of the lung can potentially be the first choice imaging technique in pregnant women with suspected pulmonary tuberculosis.


Assuntos
Pulmão/microbiologia , Pulmão/patologia , Imageamento por Ressonância Magnética , Tuberculose Pulmonar/diagnóstico , Antituberculosos/uso terapêutico , Diagnóstico Diferencial , Feminino , Humanos , Gravidez , Resultado do Tratamento , Tuberculose Pulmonar/tratamento farmacológico , Adulto Jovem
2.
J Magn Reson Imaging ; 18(6): 714-25, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14635157

RESUMO

PURPOSE: To determine the accuracy of single-kidney glomerular filtration rate (GFR) determination using contrast-enhanced dynamic magnetic resonance imaging (MRI) and the Rutland-Patlak plot technique. MATERIALS AND METHODS: Twenty-eight adult patients were included. As reference method, the GFR was measured by plasma clearance using a small bolus injection of iopromide. A three-dimensional gradient-echo (GRE) sequence with a flip angle of 50 degrees was used for MRI; this showed a good linear relationship between gadolinium (Gd)-DTPA concentration and signal change when measured up to a Gd-DTPA concentration of 10 mmol/liter. A slab containing both kidneys and the abdominal aorta was measured 30 times in approximately 3.5 minutes. During this measurement, 15 mL of Gd-DTPA, 0.5 mol/liter diluted to a volume of 60 mL, was injected over 60 seconds. A Rutland-Patlak plot was calculated from the signal changes in the aorta and the renal parenchyma. Single-kidney GFR was calculated for different time windows from the Rutland-Patlak plot slope. RESULTS: The best correlation compared to the reference method was found with the GFR calculated from the slope of the Rutland-Patlak plot 40-110 seconds postaortic rise. Pearson's correlation coefficient was r = 0.86, SD was 14.8 mL/minute. In many of the patients, a decrease of the renal signal was observed in the excretory phase, which was probably caused by very high Gd-DTPA concentrations in the collecting tubules. CONCLUSION: Single-kidney GFR can be calculated from dynamic contrast-enhanced MRI. We found a promising correlation of global GFR calculated by MRI compared to the reference method. In any future study, the amount of Gd-DTPA should by reduced to avoid artificial signal drop in the excretory phase induced by the T2* effect.


Assuntos
Meios de Contraste , Imagem Ecoplanar/métodos , Gadolínio DTPA , Taxa de Filtração Glomerular/fisiologia , Nefropatias/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/administração & dosagem , Imagem Ecoplanar/instrumentação , Feminino , Gadolínio DTPA/administração & dosagem , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Nefropatias/etiologia , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Imagens de Fantasmas , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA