Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 105
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Ann Surg Oncol ; 31(1): 344-355, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37903951

RESUMO

BACKGROUND: Tailored axillary surgery (TAS) is a novel surgical concept for clinical node-positive breast cancer. It consists of the removal of the sentinel lymph nodes (LNs), as well as palpably suspicious nodes. The TAS technique can be utilized in both the upfront and neoadjuvant chemotherapy (NACT) setting. This study assessed whether/how imaging-guided localization (IGL) influenced TAS. PATIENTS AND METHODS: This was a prospective observational cohort study preplanned in the randomized phase-III OPBC-03/TAXIS trial. IGL was performed at the surgeon's discretion for targeted removal of LNs during TAS. Immediate back-up axillary lymph node dissection (ALND) followed TAS according to TAXIS randomization. RESULTS: Five-hundred patients were included from 44 breast centers in six countries, 151 (30.2%) of whom underwent NACT. IGL was performed in 84.4% of all patients, with significant variation by country (77.6-100%, p < 0.001). No difference in the median number of removed (5 vs. 4, p = 0.3) and positive (2 vs. 2, p = 0.6) LNs by use of IGL was noted. The number of LNs removed during TAS with IGL remained stable over time (p = 0.8), but decreased significantly without IGL, from six (IQR 4-6) in 2019 to four (IQR 3-4) in 2022 (p = 0.015). An ALND was performed in 249 patients, removing another 12 (IQR 9-17) LNs, in which a median number of 1 (IQR 0-4) was positive. There was no significant difference in residual nodal disease after TAS with or without IGL (68.0% vs. 57.6%, p = 0.2). CONCLUSIONS: IGL did not significantly change either the performance of TAS or the volume of residual nodal tumor burden. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03513614.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Neoplasias da Mama/patologia , Biópsia de Linfonodo Sentinela/métodos , Estudos Prospectivos , Metástase Linfática/patologia , Excisão de Linfonodo/métodos , Terapia Neoadjuvante , Axila/patologia , Linfonodos/cirurgia , Linfonodos/patologia
2.
Strahlenther Onkol ; 200(6): 461-467, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38393398

RESUMO

PURPOSE: To summarize the radiotherapy-relevant statements of the 18th St. Gallen Breast Cancer Consensus Conference and interpret the findings in light of German guideline recommendations. METHODS: Statements and voting results from the 18th St. Gallen International Breast Cancer Consensus Conference were collected and analyzed according to their relevance for the radiation oncology community. The voting results were discussed in two hybrid meetings among the authors of this manuscript on March 18 and 19, 2023, in light of the German S3 guideline and the 2023 version of the Arbeitsgemeinschaft Gynäkologische Onkologie (AGO) guidelines. RESULTS AND CONCLUSION: There was a high level of agreement between the radiotherapy-related statements of the 18th St. Gallen International Breast Cancer Consensus Conference and the German S3 and AGO guidelines. Discrepancies include the impact of number of lymph node metastases for the indication for postmastectomy radiotherapy.


Assuntos
Neoplasias da Mama , Neoplasias da Mama/radioterapia , Humanos , Feminino , Alemanha , Guias de Prática Clínica como Assunto , Metástase Linfática/radioterapia , Metástase Linfática/patologia , Radioterapia (Especialidade)/normas , Radioterapia Adjuvante
3.
J Ultrasound Med ; 43(1): 109-114, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37772458

RESUMO

OBJECTIVES: Shear wave elastography (SWE) is increasingly used in breast cancer diagnostics. However, large, prospective, multicenter data evaluating the reliability of SWE is missing. We evaluated the intra- and interobserver reliability of SWE in patients with breast lesions categorized as BIRADS 3 or 4. METHODS: We used data of 1288 women at 12 institutions in 7 countries with breast lesions categorized as BIRADS 3 to 4 who underwent conventional B-mode ultrasound and SWE. 1243 (96.5%) women had three repetitive conventional B-mode ultrasounds as well as SWE measurements performed by a board-certified senior physician. 375 of 1288 (29.1%) women received an additional ultrasound examination with B-mode and SWE by a second physician. Intraclass correlation coefficients (ICC) were calculated to examine intra- and interobserver reliability. RESULTS: ICC for intraobserver reliability showed an excellent correlation with ICC >0.9, while interobserver reliability was moderate with ICC of 0.7. There were no clinically significant differences in intraobserver reliability when SWE was performed in lesions categorized as BI-RADS 3 or 4 as well as in histopathologically benign or malignant lesions. CONCLUSION: Reliability of additional SWE was evaluated on a study cohort consisting of 1288 breast lesions categorized as BI-RADS 3 and 4. SWE shows an excellent intraobserver reliability and a moderate interobserver reliability in the evaluation of solid breast masses.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Humanos , Feminino , Masculino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Ultrassonografia Mamária , Estudos Prospectivos , Reprodutibilidade dos Testes , Mama/diagnóstico por imagem , Mama/patologia , Sensibilidade e Especificidade , Diagnóstico Diferencial
4.
Breast Cancer Res Treat ; 201(1): 57-66, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37302085

RESUMO

PURPOSE: A previous study in our breast unit showed that the diagnostic accuracy of intraoperative specimen radiography and its potential to reduce second surgeries in a cohort of patients treated with neoadjuvant chemotherapy were low, which questions the routine use of Conventional specimen radiography (CSR) in this patient group. This is a follow-up study in a larger cohort to further evaluate these findings. METHODS: This retrospective study included 376 cases receiving breast-conserving surgery (BCS) after neoadjuvant chemotherapy (NACT) of primary breast cancer. CSR was performed to assess potential margin infiltration and recommend an intraoperative re-excision of any radiologically positive margin. The histological workup of the specimen served as gold standard for the evaluation of the accuracy of CSR and the potential reduction of second surgeries by CSR-guided re-excisions. RESULTS: 362 patients with 2172 margins were assessed. The prevalence of positive margins was 102/2172 (4.7%). CSR had a sensitivity of 37.3%, a specificity of 85.6%, a positive predictive value (PPV) of 11.3%, and a negative predictive value (NPV) of 96.5%. The rate of secondary procedures was reduced from 75 to 37 with a number needed to treat (NNT) of CSR-guided intraoperative re-excisions of 10. In the subgroup of patients with clinical complete response (cCR), the prevalence of positive margins was 38/1002 (3.8%), PPV was 6.5% and the NNT was 34. CONCLUSION: This study confirms our previous finding that the rate of secondary surgeries cannot be significantly reduced by CSR-guided intraoperative re-excisions in cases with cCR after NACT. The routine use CSR after NACT is questionable, and alternative tools of intraoperative margin assessment should be evaluated.


Assuntos
Neoplasias da Mama , Carcinoma Ductal de Mama , Humanos , Feminino , Terapia Neoadjuvante/métodos , Seguimentos , Estudos Retrospectivos , Carcinoma Ductal de Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/cirurgia , Mastectomia Segmentar/métodos , Margens de Excisão , Radiografia
5.
J Ultrasound Med ; 42(8): 1729-1736, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36789976

RESUMO

OBJECTIVES: We evaluated whether lesion-to-fat ratio measured by shear wave elastography in patients with Breast Imaging Reporting and Data System (BI-RADS) 3 or 4 lesions has the potential to further refine the assessment of B-mode ultrasound alone in breast cancer diagnostics. METHODS: This was a secondary analysis of an international diagnostic multicenter trial (NCT02638935). Data from 1288 women with breast lesions categorized as BI-RADS 3 and 4a-c by conventional B-mode ultrasound were analyzed, whereby the focus was placed on differentiating lesions categorized as BI-RADS 3 and BI-RADS 4a. All women underwent shear wave elastography and histopathologic evaluation functioning as reference standard. Reduction of benign biopsies as well as the number of missed malignancies after reclassification using lesion-to-fat ratio measured by shear wave elastography were evaluated. RESULTS: Breast cancer was diagnosed in 368 (28.6%) of 1288 lesions. The assessment with conventional B-mode ultrasound resulted in 53.8% (495 of 1288) pathologically benign lesions categorized as BI-RADS 4 and therefore false positives as well as in 1.39% (6 of 431) undetected malignancies categorized as BI-RADS 3. Additional lesion-to-fat ratio in BI-RADS 4a lesions with a cutoff value of 1.85 resulted in 30.11% biopsies of benign lesions which correspond to a reduction of 44.04% of false positives. CONCLUSIONS: Adding lesion-to-fat ratio measured by shear wave elastography to conventional B-mode ultrasound in BI-RADS 4a breast lesions could help reduce the number of benign biopsies by 44.04%. At the same time, however, 1.98% of malignancies were missed, which would still be in line with American College of Radiology BI-RADS 3 definition of <2% of undetected malignancies.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Humanos , Feminino , Sensibilidade e Especificidade , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia Mamária/métodos , Reprodutibilidade dos Testes , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Biópsia , Elasticidade , Diagnóstico Diferencial
6.
Arch Gynecol Obstet ; 308(1): 219-229, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36604331

RESUMO

PURPOSE: Today, the decision to treat patients with chemotherapy for early breast cancer (EBC) is made based on the patient's individual risk stratification and tumor biology. In cases with chemotherapy indication, the neoadjuvant application (NACT) is the preferred option in comparison with primary surgery and adjuvant chemotherapy (ACT). Age remains a relevant factor in the decision-making process. The aim of the present study was to illustrate the impact of age on the use of systemic therapy in clinical routine. METHODS: The study separately analyzed chemotherapy use among six age cohorts of EBC patients who had been treated at 104 German breast units between January 2008 and December 2017. RESULTS: In total, 124,084 patients were included, 46,279 (37.3%) of whom had received chemotherapy. For 44,765 of these cases, detailed information on treatment was available. Within this cohort, chemotherapy was administered as NACT to 14,783 patients (33.0%) and as ACT to 29,982 (67.0%) patients. Due to the higher prevalence of unfavorable tumor subtypes, younger patients had a higher rate of chemotherapy (≤ 29y: 74.2%; 30-39y: 71.3%) and a higher proportion of NACT administration ( ≤ 29y: 66.9%; 30-39y: 56.0%) in comparison with elderly patients, who had lower rates for overall chemotherapy (60-69y: 37.5%; ≥ 70y: 17.6%) and NACT (60-69y: 25.5%; ≥ 70y: 22.8%). Pathologic complete response was higher in younger than in older patients (≤ 29y: 30.4% vs. ≥ 70y: 16.7%), especially for HER2- subtypes. CONCLUSION: The data from the nationwide German cohort reveal relevant age-dependent discrepancies concerning the use of chemotherapy for EBC.


Assuntos
Neoplasias da Mama , Humanos , Idoso , Feminino , Neoplasias da Mama/patologia , Quimioterapia Adjuvante , Terapia Neoadjuvante/métodos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos
7.
Ultraschall Med ; 44(2): 162-168, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34425600

RESUMO

PURPOSE: In this prospective, multicenter trial we evaluated whether additional shear wave elastography (SWE) for patients with BI-RADS 3 or 4 lesions on breast ultrasound could further refine the assessment with B-mode breast ultrasound for breast cancer diagnosis. MATERIALS AND METHODS: We analyzed prospective, multicenter, international data from 1288 women with breast lesions rated by conventional 2 D B-mode ultrasound as BI-RADS 3 to 4c and undergoing 2D-SWE. After reclassification with SWE the proportion of undetected malignancies should be < 2 %. All patients underwent histopathologic evaluation (reference standard). RESULTS: Histopathologic evaluation showed malignancy in 368 of 1288 lesions (28.6 %). The assessment with B-mode breast ultrasound resulted in 1.39 % (6 of 431) undetected malignancies (malignant lesions in BI-RADS 3) and 53.80 % (495 of 920) unnecessary biopsies (biopsies in benign lesions). Re-classifying BI-RADS 4a patients with a SWE cutoff of 2.55 m/s resulted in 1.98 % (11 of 556) undetected malignancies and a reduction of 24.24 % (375 vs. 495) of unnecessary biopsies. CONCLUSION: A SWE value below 2.55 m/s for BI-RADS 4a lesions could be used to downstage these lesions to follow-up, and therefore reduce the number of unnecessary biopsies by 24.24 %. However, this would come at the expense of some additionally missed cancers compared to B-mode breast ultrasound (rate of undetected malignancies 1.98 %, 11 of 556, versus 1.39 %, 6 of 431) which would, however, still be in line with the ACR BI-RADS 3 definition (< 2 % of undetected malignancies).


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Feminino , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Técnicas de Imagem por Elasticidade/métodos , Estudos Prospectivos , Sensibilidade e Especificidade , Diagnóstico Diferencial , Reprodutibilidade dos Testes , Ultrassonografia Mamária/métodos , Biópsia
8.
Ultraschall Med ; 44(5): 520-536, 2023 Oct.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-37072031

RESUMO

Alongside mammography, breast ultrasound is an important and well-established method in assessment of breast lesions. With the "Best Practice Guideline", the DEGUM Breast Ultrasound (in German, "Mammasonografie") working group, intends to describe the additional and optional application modalities for the diagnostic confirmation of breast findings and to express DEGUM recommendations in this Part II, in addition to the current dignity criteria and assessment categories published in Part I, in order to facilitate the differential diagnosis of ambiguous lesions.The present "Best Practice Guideline" has set itself the goal of meeting the requirements for quality assurance and ensuring quality-controlled performance of breast ultrasound. The most important aspects of quality assurance are explained in this Part II of the Best Practice Guideline.


Assuntos
Mamografia , Ultrassonografia Mamária , Feminino , Humanos , Mamografia/métodos
9.
Breast Cancer Res Treat ; 191(3): 589-598, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34878635

RESUMO

PURPOSE: This is the first study to systematically evaluate the diagnostic accuracy of intraoperative specimen radiography on margin level and its potential to reduce second surgeries in patients treated with neoadjuvant chemotherapy. METHODS: This retrospective study included 174 cases receiving breast conserving surgery (BCS) after neoadjuvant chemotherapy (NACT) of primary breast cancer. Conventional specimen radiography (CSR) was performed to assess potential margin infiltration and recommend an intraoperative re-excision of any radiologically positive margin. The histological workup of the specimen served as gold standard for the evaluation of the accuracy of CSR and the potential reduction of second surgeries by CSR-guided re-excisions. RESULTS: 1044 margins were assessed. Of 47 (4.5%) histopathological positive margins, CSR identified 9 correctly (true positive). 38 infiltrated margins were missed (false negative). This resulted in a sensitivity of 19.2%, a specificity of 89.2%, a positive predictive value (PPV) of 7.7%, and a negative predictive value (NPV) of 95.9%. The rate of secondary procedures was reduced from 23 to 16 with a number needed to treat (NNT) of CSR-guided intraoperative re-excisions of 25. In the subgroup of patients with cCR, the prevalence of positive margins was 10/510 (2.0%), PPV was 1.9%, and the NNT was 85. CONCLUSION: Positive margins after NACT are rare and CSR has only a low sensitivity to detect them. Thus, the rate of secondary surgeries cannot be significantly reduced by recommending targeted re-excisions, especially in cases with cCR. In summary, CSR after NACT is inadequate for intraoperative margin assessment but remains useful to document removal of the biopsy site clip.


Assuntos
Neoplasias da Mama , Carcinoma Ductal de Mama , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/cirurgia , Feminino , Humanos , Mastectomia Segmentar , Terapia Neoadjuvante , Radiografia , Estudos Retrospectivos
10.
Ann Surg Oncol ; 29(2): 1061-1070, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34647202

RESUMO

INTRODUCTION: Recent data suggest that margins ≥2 mm after breast-conserving surgery may improve local control in invasive breast cancer (BC). By allowing large resection volumes, oncoplastic breast-conserving surgery (OBCII; Clough level II/Tübingen 5-6) may achieve better local control than conventional breast conserving surgery (BCS; Tübingen 1-2) or oncoplastic breast conservation with low resection volumes (OBCI; Clough level I/Tübingen 3-4). METHODS: Data from consecutive high-risk BC patients treated in 15 centers from the Oncoplastic Breast Consortium (OPBC) network, between January 2010 and December 2013, were retrospectively reviewed. RESULTS: A total of 3,177 women were included, 30% of whom were treated with OBC (OBCI n = 663; OBCII n = 297). The BCS/OBCI group had significantly smaller tumors and smaller resection margins compared with OBCII (pT1: 50% vs. 37%, p = 0.002; proportion with margin <1 mm: 17% vs. 6%, p < 0.001). There were significantly more re-excisions due to R1 ("ink on tumor") in the BCS/OBCI compared with the OBCII group (11% vs. 7%, p = 0.049). Univariate and multivariable regression analysis adjusted for tumor biology, tumor size, radiotherapy, and systemic treatment demonstrated no differences in local, regional, or distant recurrence-free or overall survival between the two groups. CONCLUSIONS: Large resection volumes in oncoplastic surgery increases the distance from cancer cells to the margin of the specimen and reduces reexcision rates significantly. With OBCII larger tumors are resected with similar local, regional and distant recurrence-free as well as overall survival rates as BCS/OBCI.


Assuntos
Neoplasias da Mama , Mamoplastia , Neoplasias da Mama/cirurgia , Feminino , Humanos , Mastectomia Segmentar , Estudos Retrospectivos , Resultado do Tratamento
11.
Ultraschall Med ; 43(6): 570-582, 2022 Dec.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-34921376

RESUMO

For many years, breast ultrasound has been used in addition to mammography as an important method for clarifying breast findings. However, differences in the interpretation of findings continue to be problematic 1 2. These differences decrease the diagnostic accuracy of ultrasound after detection of a finding and complicate interdisciplinary communication and the comparison of scientific studies 3. In 1999, the American College of Radiology (ACR) created a working group (International Expert Working Group) that developed a classification system for ultrasound examinations based on the established BI-RADS classification of mammographic findings under consideration of literature data 4. Due to differences in content, the German Society for Ultrasound in Medicine (DEGUM) published its own BI-RADS-analogue criteria catalog in 2006 3. In addition to the persistence of differences in content, there is also an issue with formal licensing with the current 5th edition of the ACR BI-RADS catalog, even though the content is recognized by the DEGUM as another system for describing and documenting findings. The goal of the Best Practice Guideline of the Breast Ultrasound Working Group of the DEGUM is to provide colleagues specialized in senology with a current catalog of ultrasound criteria and assessment categories as well as best practice recommendations for the various ultrasound modalities.


Assuntos
Neoplasias da Mama , Medicina , Feminino , Humanos , Ultrassonografia Mamária/métodos , Mamografia/métodos , Neoplasias da Mama/diagnóstico por imagem
12.
Ann Surg Oncol ; 28(13): 8742-8751, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34279753

RESUMO

BACKGROUND: Poor patient-reported satisfaction after breast-conserving therapy (BCT) has been associated with impaired health-related quality of life (HRQOL) and subsequent depression in retrospective analysis. This prospective cohort study aimed to assess the HRQOL of patients who have undergone BCT using the BREAST-Q, and to identify clinical risk factors for lower patient satisfaction. METHODS: Patients with primary breast cancer undergoing BCT were asked to complete the BREAST-Q preoperatively (T1) for baseline evaluation, then 3 to 4 weeks postoperatively (T2), and finally 1 year after surgery (T3). Clinicopathologic data were extracted from the patients' charts. Repeated measures analysis of variance (ANOVA) was used to determine significant differences in mean satisfaction and well-being levels among the test intervals. Multiple linear regression was used to evaluate risk factors for lower satisfaction. RESULTS: The study enrolled 250 patients. The lowest baseline BREAST-Q score was reported for "satisfaction with breast" (mean, 61 ± 19), but this increased postoperatively (mean, 66 ± 18) and was maintained at the 1 year follow-up evaluation (mean, 67 ± 21). "Physical well-being" decreased from T1 (mean, 82 ± 17) to T2 (mean, 28 ± 13) and did not recover much by T3 (mean, 33 ± 13), being the lowest BREAST-Q score postoperatively and in the 1-year follow-up evaluation. In multiple regression, baseline psychosocial well-being, body mass index (BMI), and type of incision were risk factors for lower "satisfaction with breasts." CONCLUSION: Both the aesthetic/surgery-related and psychological aspects are equally important with regard to "satisfaction with breasts" after BCT. The data could serve as the benchmark for future studies.


Assuntos
Satisfação do Paciente , Qualidade de Vida , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Inquéritos e Questionários
13.
Breast Cancer Res Treat ; 179(2): 425-433, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31654190

RESUMO

PURPOSE: To explore the ability of intraoperative specimen radiography (SR) to correctly identify positive margins in patients receiving breast conserving surgery (BCS). To assess whether the reoperation rate can be reduced by using this method. METHODS: This retrospective study included 470 consecutive cases receiving BCS due to a primarily diagnosed breast cancer. SR was carried out in two planes, assessing the specimen regarding the presence of the lesion and its relation to all margins. If indicated, re-excision of selective orientations was advised. Under consideration of gross inspection and the SR-findings, it was up to the surgeon whether to perform re-resections. The recommendations for re-excision were, separately for each orientation, compared to the histopathological results, serving as gold standard. RESULTS: Intraoperative SR was performed in 470 cases, thus 2820 margins were assessed. Of those, 2510 (89.0%) were negative and 310 (11.0%) positive. SR identified 2179 (77.3%) margins correctly as negative, whereas 331 (11.7%) clear margins were misjudged as positive. Of 310 infiltrated margins, SR identified 114 (4.0%) correctly, whereas 196 (7.0%) infiltrated margins were missed. This resulted in a sensitivity/specificity of 36.8%/86.8% and PPV/NPV of 25.6%/91.8%. Through targeted re-resections positive margins could be reduced by 31.0% [310 to 214 (7.6%)]. On case level, the rate of secondary procedures could be reduced by 37.0% [from 162 to 102 (21.7%)]. CONCLUSIONS: SR is a helpful tool to identify infiltrated margins and to reduce the rate of secondary surgeries by recommending targeted re-excisions of according orientations in order to obtain a final negative margin status.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/cirurgia , Cuidados Intraoperatórios , Mastectomia Segmentar , Radiografia , Idoso , Biópsia , Feminino , Humanos , Cuidados Intraoperatórios/métodos , Margens de Excisão , Mastectomia Segmentar/métodos , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Radiografia/métodos , Cirurgia Assistida por Computador , Terapêutica , Resultado do Tratamento
14.
Int J Mol Sci ; 21(17)2020 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-32899175

RESUMO

BACKGROUND: SRY-related HMG-box 10 (SOX-10) is commonly expressed in triple negative breast cancer (TNBC). However, data on the biological significance of SOX-10 expression is limited. Therefore, we investigated immunhistological SOX-10 expression in TNBC and correlated the results with genetic alterations and clinical data. METHODS: A tissue microarray including 113 TNBC cases was stained by SOX-10. Immunohistological data of AR, BCL2, CD117, p53 and Vimentin was available from a previous study. Semiconductor-based panel sequencing data including commonly altered breast cancer genes was also available from a previous investigation. SOX-10 expression was correlated with clinicopathological, immunohistochemical and genetic data. RESULTS: SOX-10 was significantly associated with CD117 and Vimentin, but not with AR expression. An association of SOX-10 with BCL2, EGFR or p53 staining was not observed. SOX-10-positive tumors harbored more often TP53 mutations but less frequent mutations of PIK3CA or alterations of the PIK3K pathway. SOX-10 expression had no prognostic impact either on disease-free, distant disease-free, or overall survival. CONCLUSIONS: While there might be a value of SOX-10 as a differential diagnostic marker to identify metastases of TNBC, its biological role remains to be investigated.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Biomarcadores Tumorais/metabolismo , Carcinoma Lobular/patologia , Fatores de Transcrição SOXE/metabolismo , Neoplasias de Mama Triplo Negativas/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Lobular/tratamento farmacológico , Carcinoma Lobular/metabolismo , Estudos de Coortes , Feminino , Seguimentos , Regulação Neoplásica da Expressão Gênica , Humanos , Pessoa de Meia-Idade , Prognóstico , Taxa de Sobrevida , Neoplasias de Mama Triplo Negativas/tratamento farmacológico , Neoplasias de Mama Triplo Negativas/metabolismo
15.
Pathologe ; 41(4): 393-399, 2020 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-32405655

RESUMO

The classical Paget's disease of the nipple is histologically characterized by tumor cell infiltration originating in intraductal or invasive breast carcinoma, immunohistologically by a frequent overexpression of HER2 and clinically by eczema-like changes of the nipple and areola. Variants with different histological, immunohistological, and clinical features are observed in nonclassical forms of Paget's disease, such as isolated Paget's disease of the nipple, anaplastic Paget's disease, Paget's disease with invasion, and pigmented Paget's disease of the nipple. In the differential diagnosis of Paget's disease, benign changes have to be considered, including Toker cell hyperplasia, nipple eczema, and rare dermatoses.


Assuntos
Neoplasias da Mama , Doença de Paget Mamária , Neoplasias da Mama/patologia , Diagnóstico Diferencial , Humanos , Hiperplasia/patologia , Mamilos/patologia , Doença de Paget Mamária/diagnóstico , Doença de Paget Mamária/patologia
16.
Pathologe ; 41(5): 515-522, 2020 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-32458047

RESUMO

The nipple-areola complex is the origin of various morphologically distinct tumors and tumor-like lesions, which can be delineated from the special structures of the nipple, in particular the intramammary ducts, skin-appendages, and the intramammary stroma. Benign tumors are most frequent and this includes epithelial tumors such as mammary adenoma and syringomatous tumor of the nipple. Less commonly observed are benign mesenchymal tumors such as leiomyoma of the nipple, or tumor-like lesions like pseudo-lymphoma. With excess formations of the nipple, the different forms of polythelia and polymastia have to be considered.


Assuntos
Adenoma , Neoplasias da Mama , Leiomioma , Mamilos , Adenoma/diagnóstico , Neoplasias da Mama/diagnóstico , Humanos , Leiomioma/diagnóstico , Mamilos/patologia , Pele
17.
Int J Cancer ; 144(11): 2833-2842, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-30426507

RESUMO

In recent years, metabolites have attracted substantial attention as promising novel biomarkers of various diseases. However, breast cancer plasma metabolite studies are still in their infancy. Here, we investigated the potential of metabolites to serve as minimally invasive, early detection markers of primary breast cancer. We profiled metabolites extracted from the plasma of primary breast cancer patients and healthy controls using tandem mass spectrometry (UHPLC-MS/MS and FIA-MS/MS). Two metabolites were found to be upregulated, while 16 metabolites were downregulated in primary breast cancer patients compared to healthy controls in both the training and validation cohorts. A panel of seven metabolites was selected by LASSO regression analysis. This panel could differentiate primary breast cancer patients from healthy controls, with an AUC of 0.87 (95% CI: 0.81 ~ 0.92) in the training cohort and an AUC of 0.80 (95% CI: 0.71 ~ 0.87) in the validation cohort. These significantly differentiated metabolites are mainly involved in the amino acid metabolism and breast cancer cell growth pathways. In conclusion, using a metabolomics approach, we identified metabolites that have potential value for development of a multimarker blood-based test to complement and improve early breast cancer detection. The panel identified herein might be part of a prescreening tool, especially for younger women or for closely observing women with certain risks, to facilitate decision making regarding which individuals should undergo further diagnostic tests. In the future, the combination of metabolites and other blood-based molecular marker sets, such as DNA methylation, microRNA, and cell-free DNA mutation markers, will be an attractive option.


Assuntos
Biomarcadores Tumorais/sangue , Neoplasias da Mama/diagnóstico , Detecção Precoce de Câncer/métodos , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais/metabolismo , Neoplasias da Mama/sangue , Neoplasias da Mama/metabolismo , Estudos de Coortes , Feminino , Humanos , Metabolômica/métodos , Pessoa de Meia-Idade , Curva ROC
18.
Breast Cancer Res Treat ; 177(2): 457-467, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31236814

RESUMO

PURPOSE: In the ACOSOG Z0011 trial, patients with primary breast cancer (BC) and 1-2 tumor-involved sentinel lymph nodes (SLN) undergoing breast-conserving surgery gained no benefit from completing axillary lymph node dissection (cALND). This paper reports cALND rates performed in clinical routine on patients who would meet the Z0011 criteria. Further, patients still received cALND were analyzed concerning the number of non-sentinel metastases (NSM) to estimate occult axillary tumor burden. METHODS: Data were retrospectively analyzed from patients treated in 179 German breast centers between 2008 and 2015. Time-trend rates were determined for cALND regarding the presence of axillary macrometastases or micrometastases. Descriptive statistics were used to report the number of NSM depending on the number of SLN removed, tumor-involved SLN, tumor stage (pT1-2), and immunohistochemical subtype. Factors associated with NSM were identified using multivariable logistic regression. RESULTS: Altogether, data for 188,909 patients were available, of whom 13,741 (7.3%) were identified eligible for the Z0011 criteria. For these patients, the cALND rate for macrometastases declined from 96.4% in 2008 to 49.7% in 2015, for micrometastases from 86.7 to 5.9%. In total 9773 patients still received cALND, 33.4% of whom had NSM. The NSM rates were: 38.8% for pN(1/1sn), 28.6% for pN(1/2sn), and 50.9% for pN(2/2sn). Hormone receptor (HR) positive/HER2+ showed the highest NSM rate (41.6%), HR-/HER2- the lowest rate (29.4%). CONCLUSIONS: The rate of cALND for ACOSOG Z0011 eligible patients has decreased substantially in routine care in our nationwide cohort. Our data reveal a relatively high prevalence of additional axillary NSM tumor burden.


Assuntos
Axila/patologia , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Linfonodo Sentinela/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais , Neoplasias da Mama/etiologia , Tomada de Decisão Clínica , Estudos de Coortes , Gerenciamento Clínico , Feminino , Humanos , Excisão de Linfonodo , Metástase Linfática , Mastectomia Segmentar , Pessoa de Meia-Idade , Estudos Retrospectivos , Biópsia de Linfonodo Sentinela , Adulto Jovem
19.
Breast Cancer Res Treat ; 173(2): 429-438, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30315437

RESUMO

PURPOSE: In the American College of Surgeons Oncology Group (ACOSOG) Z0011 trial, patients with 1 or 2 tumour-involved sentinel lymph nodes (SLNs) gained no benefit from completion axillary lymph dissection (cALND). We examined implementation of evidence from this trial into routine clinical management. METHODS: Data were included from patients diagnosed with primary breast cancer in German breast cancer units between 2008 and 2015 and analysed retrospectively from a prospective maintained database. Descriptive analyses assessed time-trend changes in axillary surgery. Factors associated with cALND in patients with 1 or 2 positive SLNs were identified using multivariable logistic regression analysis. RESULTS: Overall, 179 breast cancer units provided data for 188,909 patients, of whom 13,741 (7.3%) had pT1/2cN0M0 invasive breast cancer with 1 or 2 tumour-involved SLNs and underwent breast-conserving surgery and adjuvant radiotherapy. cALND use decreased from 94.6% in 2008 to 46.9% in 2015 (p < 0.001). In multivariable analyses, the following factors were associated with cALND: fewer removed SLNs; two tumour-affected SLNs; younger age; lower annual case volume per hospital; higher tumour grade and lymphovascular invasion. No statistically significant influence was detected for hormone receptor or HER2 status. CONCLUSION: In our cohort, 7.3% of patients with primary breast cancer met the ACOSOG Z0011 inclusion criteria and could potentially have been spared the morbidity of cALND. cALND tended to be performed in patients with a higher axillary tumour burden. This study shows a shift towards less extensive axillary surgery through rapid implementation of new clinical trial evidence into routine clinical practice.


Assuntos
Neoplasias da Mama/terapia , Excisão de Linfonodo/estatística & dados numéricos , Metástase Linfática/patologia , Biópsia de Linfonodo Sentinela/estatística & dados numéricos , Linfonodo Sentinela/cirurgia , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Axila , Mama/patologia , Mama/cirurgia , Neoplasias da Mama/patologia , Feminino , Humanos , Excisão de Linfonodo/normas , Mastectomia Segmentar , Pessoa de Meia-Idade , Seleção de Pacientes , Guias de Prática Clínica como Assunto , Estudos Prospectivos , Radioterapia Adjuvante/estatística & dados numéricos , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Retrospectivos , Linfonodo Sentinela/patologia , Adulto Jovem
20.
Breast Cancer Res Treat ; 173(1): 135-143, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30255454

RESUMO

PURPOSE: Chemotherapy-induced alopecia (CIA) is a distressing side effect for women with breast cancer undergoing chemotherapy. Scalp cooling is a method aiming to prevent CIA, but its efficacy is not well defined. Randomized trials until recently and at the time this trial was designed have been lacking. METHODS: Patients undergoing (neo)adjuvant chemotherapy for early breast cancer (EBC) were randomized to scalp cooling (CAP) or observation (NoCAP). All patients received 18-24 weeks of anthracycline- and/or taxane-based chemotherapy. The primary endpoint was patient-reported rate of alopecia according to a modified version of the Dean Scale. Hair preservation was defined as hair loss ≤ grade 2 (≤ 50%). Secondary endpoints were rate of alopecia determined by medical staff, rate of wig/scarf use, tolerability as well as quality of life (QoL). RESULTS: Seventy-nine patients were randomized. Hair preservation was observed in 39.3% of patients in the CAP arm versus 0% in the NoCAP arm (p < 0.001). Wig/scarf use was significantly less frequent in the CAP group (40.7% vs 95.5% outside home before cycle 3, p < 0.001). The drop-out rate was 31.7% and 34.2% in the CAP and NoCAP arm, respectively. Main reasons for drop-out were hair loss, adverse events (CAP), and randomization into control arm. We observed no differences in efficacy between anthracycline-based and non-anthracycline-based regimens. QoL did not differ between the study arms. CONCLUSIONS: This trial adds to the evidence that scalp cooling effectively prevents CIA in a meaningful number of patients. This option should be made available for patients undergoing (neo)adjuvant chemotherapy for EBC.


Assuntos
Alopecia/prevenção & controle , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Neoplasias da Mama/tratamento farmacológico , Hipotermia Induzida/métodos , Terapia Neoadjuvante/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Alopecia/induzido quimicamente , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Feminino , Cabelo , Humanos , Pessoa de Meia-Idade , Terapia Neoadjuvante/efeitos adversos , Estudos Prospectivos , Qualidade de Vida , Couro Cabeludo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA