Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 225
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Arch Orthop Trauma Surg ; 144(5): 2131-2140, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38520547

RESUMO

INTRODUCTION: Treatment of both simple and complex patella fractures is a challenging clinical problem. Although tension band wiring has been the standard of care, it can be associated with high complication rates. The aim of this study was to investigate the biomechanical performance of recently developed lateral rim variable angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures. MATERIALS AND METHODS: Sixteen pairs of human anatomical knees were used to simulate either two-part transverse simple AO/OTA 34-C1 or five-part complex AO/OTA 34-C3 patella fractures by means of osteotomies, with each fracture model created in eight pairs. The complex fracture pattern was characterized by a medial and a lateral proximal fragment, together with an inferomedial, an inferolateral, and an inferior (central distal) fragment mimicking comminution around the distal patellar pole. The specimens with simple fractures were pairwise assigned for fixation with either tension band wiring through two parallel cannulated screws or a lateral rim variable angle locking plate. The knees with complex fractures were pairwise treated with either tension band wiring through two parallel cannulated screws plus circumferential cerclage wiring or a lateral rim variable angle locking plate. Each specimen was tested over 5000 cycles by pulling on the quadriceps tendon, simulating active knee extension and passive knee flexion within the range of 90° flexion to full extension. Interfragmentary movements were captured via motion tracking. RESULTS: For both fracture types, the articular displacements measured between the proximal and distal fragments at the central patella aspect between 1000 and 5000 cycles, together with the relative rotations of these fragments around the mediolateral axis were all significantly smaller following the lateral rim variable angle locked plating compared with tension band wiring, p ≤ 0.01. CONCLUSIONS: From a biomechanical perspective, lateral rim variable angle locked plating of both simple and complex patella fractures provides superior construct stability versus tension band wiring under dynamic loading.


Assuntos
Placas Ósseas , Fios Ortopédicos , Fixação Interna de Fraturas , Fraturas Ósseas , Patela , Humanos , Patela/lesões , Patela/cirurgia , Fenômenos Biomecânicos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Cadáver , Idoso , Masculino , Feminino , Fratura da Patela
2.
BMC Geriatr ; 22(1): 985, 2022 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-36539691

RESUMO

BACKGROUND: Limited information exists on nonunion treatment in the elderly. This retrospective study evaluates whether results of operative treatment of nonunion of the humerus or femur in patients aged ≥ 75 years are comparable to those in younger patients. METHODS: We identified patients age ≥ 75 years with a nonunion of humerus or femur treated with open reduction and internal fixation. The Non-Union Scoring System was calculated. Complications, clinical outcome, and radiographic findings were assessed. Primary endpoint was nonunion healing. A literature review compared time to healing of humeral and femoral nonunion in younger populations. RESULTS: We identified 45 patients treated for a nonunion of humerus or femur with > 12 months follow-up. Median age was 79 years (range 75-96). Median time to presentation was 12 months (range 4-127) after injury, median number of prior surgeries was 1 (range 0-4). Union rate was 100%, with median time to union 6 months (range 2-42). Six patients underwent revision for persistent nonunion and healed without further complications. CONCLUSIONS: Using a protocol of debridement, alignment, compression, stable fixation, bone grafting and early motion, patients aged 75 years or older can reliably achieve healing when faced with a nonunion of the humerus or femur. LEVEL OF EVIDENCE: IV.


Assuntos
Fraturas não Consolidadas , Idoso , Humanos , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Fraturas não Consolidadas/diagnóstico por imagem , Fraturas não Consolidadas/cirurgia , Fraturas não Consolidadas/etiologia , Consolidação da Fratura , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Fêmur , Resultado do Tratamento
3.
Arch Orthop Trauma Surg ; 142(12): 3605-3611, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34003368

RESUMO

INTRODUCTION: The incidence of periprosthetic femur fractures is increasing. Multiple treatment methods exist to treat fractures surrounding stable hip arthroplasty implants including locking plate fixation, cable fixation, allograft augmentation, and revision arthroplasty. No consensus regarding optimal treatment has been reached, and significant complications remain. Recently, biomechanical studies have demonstrated the benefits of orthogonal dual-plate fixation, but little clinical data exist. The purpose of the current study was to investigate the clinical and radiographic outcomes of dual-plated periprosthetic femur fractures around stable hip stems. MATERIALS AND METHODS: Patients with periprosthetic femur fractures following hip arthroplasty with a stable femoral stem treated with dual-plate fixation were identified through chart review at a single institution. Fracture classification, fixation characteristics, radiographic outcomes, clinical outcomes and complications including re-operation were recorded. RESULTS: Over a 12-year period, 31 patients (mean age 77 years at surgery, range 48-94) underwent dual plating by three traumatologists for implant-stable periprosthetic femur fractures surrounding a hip arthroplasty stem. There were 27 Vancouver B1-type and 9 inter-prosthetic fractures. Average follow-up was 2 years. Of the 26 patients with minimum 6-month follow-up, 24 (92%) united after index surgery (mean time to union 6.0 months, range 1.5-14.0). Mean time to full weight-bearing post-operatively was 2.6 months (range 1.5-4.0 months). Two patients required secondary surgery to address nonunion. CONCLUSIONS: Dual-plating achieved high union rates with an acceptable complication profile for the treatment of periprosthetic femur fractures surrounding a stable hip arthroplasty stem. Our preferred fixation construct involves a lateral plate spanning the entire femur secured with non-locking bicortical screws supplemented with an anteriorly based reconstruction plate. Additional prospective research is required to confirm the results of this study.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Fraturas Periprotéticas , Humanos , Idoso , Artroplastia de Quadril/efeitos adversos , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/etiologia , Estudos Prospectivos , Placas Ósseas/efeitos adversos , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Fixação Interna de Fraturas/métodos , Fêmur/cirurgia , Reoperação/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos
4.
J Arthroplasty ; 36(7): 2597-2602, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33714632

RESUMO

BACKGROUND: Periprosthetic femur fracture is one of the most common indications for reoperation after total hip arthroplasty. Our objectives were to evaluate the incidence of reoperation after the surgical treatment of periprosthetic femur fractures and to compare the mechanisms of failure between fractures around a stable femoral component and those with an unstable femoral component. METHODS: We identified a consecutive series of 196 surgically treated periprosthetic fractures after total hip arthroplasty between 2008 and 2017. Mean age was 72 years (range, 29-96 years), and 108 (55%) were women. The femoral component was unstable in 127 cases (65%) and stable in the remaining 69 cases (35%). Mean follow-up was 2 years. RESULTS: The 2-year cumulative probability of any reoperation was 19%. The most common indication for reoperation among the cases with a stable femoral component was nonunion, and the most common indication for reoperation among the cases with an unstable femoral component was infection. Fractures that originated at the distal aspect of the femoral component were associated with a high risk of nonunion (6 of 28 cases, P < .01) and reoperation (9 of 28 cases, P = .03). CONCLUSION: Surgeons should take measures to mitigate the failure modes that are distinct based on fracture type. The high infection rate after surgical management of B2 fracture suggests that additional antiseptic precautions may be warranted. For B1 fractures, particularly those originating near the distal aspect of the femoral component, augmenting fixation with orthogonal plating, spanning the entire femur, or revising the stem in cases of poor proximal bone should be considered.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Fraturas Periprotéticas , Idoso , Artroplastia de Quadril/efeitos adversos , Feminino , Fraturas do Fêmur/epidemiologia , Fraturas do Fêmur/etiologia , Fraturas do Fêmur/cirurgia , Fêmur/cirurgia , Fixação Interna de Fraturas , Humanos , Fraturas Periprotéticas/epidemiologia , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Reoperação , Estudos Retrospectivos
5.
Arch Orthop Trauma Surg ; 139(12): 1667-1672, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31030241

RESUMO

INTRODUCTION: Computed tomography (CT) is more accurate than plain pelvic radiography (PXR) for evaluating acetabular fracture reduction. As yet unknown is whether CT-based assessment is more predictive for clinical outcome. We determined the independent association between reduction quality according to both methods and native hip survivorship following acetabular fracture fixation. MATERIALS AND METHODS: Retrospectively, 220 acetabular fracture patients were reviewed. Reductions on PXR were graded as adequate or inadequate (0-1 mm or > 1 mm displacement) (Matta's criteria). For CT-based assessment, adequate reductions were defined as < 1 mm step and < 5 mm gap, and inadequate reductions as ≥ 1 mm step and/or ≥ 5 mm gap displacement. Predictive values and Kaplan-Meier hip survivorship curves were compared and risk factors for conversion to total hip arthroplasty (THA) were identified. RESULTS: Mean follow-up was 8.9 years (SD 5.6, range 0.5-23.3 years), and 52 patients converted to THA (24%). Adequate reductions according to CT versus PXR assessment were associated with higher predictive values for native hip survivorship (92% vs. 82%; p = 0.043). Inadequate reductions were equally predictive for conversion to THA (33% for CT and 30% for PXR; p = 0.623). For both methods, survivorship curves of adequate versus inadequate reductions were significantly different (p = 0.030 for PXR, p < 0.001 for CT). Only age ≥ 50 years (p < 0.001) and inadequate reductions as assessed on CT (p = 0.038) were found to be independent risk factors for conversion to THA. Reduction quality as assessed on PXR was not found to be independently predictive for this outcome (p = 0.585). CONCLUSION: Native hip survivorship is better predicted based on postoperative CT imaging as compared to PXR assessment. Predicting need for THA in patients with inadequate reductions based on both assessment methods remains challenging. While both PXR and CT-based methods are associated with hip survivorship, only an inadequate reduction according to CT assessment was an independent risk factor for conversion to THA.


Assuntos
Acetábulo/diagnóstico por imagem , Fraturas do Quadril/diagnóstico por imagem , Radiografia , Tomografia Computadorizada por Raios X , Acetábulo/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Feminino , Fraturas do Quadril/cirurgia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Radiografia/métodos , Estudos Retrospectivos , Sobrevivência , Tomografia Computadorizada por Raios X/métodos
6.
Oper Tech Orthop ; 28(3): 141-151, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30853772

RESUMO

Although the use of fibular strut allografts in proximal humerus fractures has gained popularity, their use in other types of fractures is less well described. Fibular allografts have recently been used in the repair of complex periarticular fractures of the proximal tibia and distal femur. Fibular allografts can be inserted in a variety of manners to achieve goals specific to each individual fracture pattern. In the proximal tibia, insertion through a fracture line or cortical window facilitates joint surface elevation, prevents subsidence and enhances overall construct stability. In distal femoral fractures, including complex periarticular fractures, insertion through the fracture or cortical window permits indirect reduction of the medial cortex and provides necessary medial column support. An additional option in distal femur fractures includes fibula insertion as an intramedullary nail, allowing enhanced fixation in short distal fracture segments. In all cases, the use of a fibular allograft augments poor bone stock and provides improved screw purchase and construct stability when combined with conventional plating methods. Here we present a series of cases at our institution illustrating an array of novel techniques utilizing endosteal fibular allografts in the fixation of complex periarticular fractures about the knee.

7.
Arch Orthop Trauma Surg ; 137(8): 1067-1070, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28500457

RESUMO

INTRODUCTION: Isolated greater tuberosity (GT) fractures (AO 11-A1) tend to occur in the younger patient population and are poorly managed by most precontoured proximal humerus locking plates. The goal of this study was to identify and assess an alternative treatment strategy for greater tuberosity fractures. MATERIALS AND METHODS: A retrospective review of all cases of isolated greater tuberosity fractures treated with a 2.4/2.7 mesh plate (Synthes) between 2010 and 2015 was conducted. Patient demographics, operative reports, and clinical notes were reviewed. The time to radiographic union was assessed. Clinical outcomes were retrieved from patients at their follow-up visits or via mailed Disabilities of the Arm, Shoulder, Hand (DASH) questionnaires. RESULTS: Ten patients with isolated GT fractures treated with mesh plating were identified with an average age of 47.1 years. The average radiographic follow-up was 7.2 months and the average clinical follow-up was 8.0 months. The mean time to union was 8.5 weeks. Two patients underwent elective hardware removal. The mean DASH at final follow-up was 28.2 (±22.4), while the mean DASH work was 13.6 (±19.1). CONCLUSION: We have identified a viable alternative treatment option for the surgical management of isolated greater tuberosity fractures using a mesh plate that can be contoured to the patient's anatomy. Surgeons should be aware of this option for select patients.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas , Úmero , Fraturas do Ombro/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/estatística & dados numéricos , Humanos , Úmero/lesões , Úmero/cirurgia , Pessoa de Meia-Idade , Estudos Retrospectivos , Inquéritos e Questionários
8.
Arch Orthop Trauma Surg ; 137(11): 1529-1538, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28849268

RESUMO

INTRODUCTION: Femoral head (FH) osteonecrosis (ON) and subsequent segmental collapse is a major concern following displaced femoral neck fractures (FNF). We aimed to quantify residual perfusion to the FH following FNF and evaluate the viability of the FH overtime after surgical fixation. MATERIALS AND METHODS: Twenty-three patients with FNF underwent dynamic contrast-enhanced (DCE)-MRI to estimate bone perfusion in the FH, using the contralateral side as control. Following open anatomic reduction and a length/angle-stable fixation, a special MRI sequence evaluated the FH for ON changes over time at 3 and 12 months after surgery. RESULTS: We found significant compromise of both arterial inflow [83.1%-initial area under the curve (IAUC) and 73.8%-peak) and venous outflow (243.2%-elimination rate (K el)] in the FH of the fractured side. The supero-medial quadrant suffered the greatest decrease in arterial inflow with a significant decrease of 71.6% (IAUC) and 68.5% (peak). Post-operative MRI revealed a high rate (87%-20/23) of small ON segments within the FH, and all developed in the anterior aspect of the supero-medial quadrants. Fracture characteristics, including subcapital FNF, varus deformity, posterior roll-off ≥20° and Pauwel's angle of 30°-50° demonstrated a greater decrease in perfusion compared to contralateral controls. CONCLUSION: FNF significantly impaired the vascular supply to the FH, resulting in high incidence of small ON segments in the supero-medial quadrant of the FH. However, maintained perfusion, probably through the inferior retinacular system, coupled with urgent open anatomic reduction and stable fixation resulted in excellent clinical and radiographic outcomes despite a high rate of small ON segments noted on MRI. LEVEL OF EVIDENCE: Level I: Prognostic Investigation.


Assuntos
Fraturas do Colo Femoral/cirurgia , Cabeça do Fêmur/cirurgia , Fixação Interna de Fraturas , Osteonecrose/etiologia , Estudos de Coortes , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Humanos
9.
Arch Orthop Trauma Surg ; 137(9): 1173-1179, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28634743

RESUMO

INTRODUCTION: Open reduction and internal fixation has long been accepted as optimal treatment for displaced olecranon fractures based on poor results seen with conservative management. With the presence of comminution, tension-band wiring constructs are contraindicated due to tendency to compress through fragments, thereby shortening the articular segment. Therefore, plate fixation is typically employed. Our hypothesis was that in a comminuted fracture model, 2.7 mm reconstruction plating without locking screws will perform equally to 3.5 mm locked plating in terms of fracture displacement and rotation (shear). MATERIALS AND METHODS: A three-part comminuted olecranon fracture pattern was created in nine matched pairs of cadaveric specimen using an oscillating saw in standardized, reproducible fashion. Each matched pair was then randomized to receive either 2.7 mm reconstruction plating or 3.5 mm proximal ulna locked plating. Random allocation software was used to assign the 2.7 mm plate construct to either the right or left side of each pair with the contralateral receiving the 3.5 mm plate construct. Specimens were cyclically loaded simulating passive range of motion exercises commonly performed during rehabilitation. Displacement and rotation in relation to the long axis of the ulna were measured through motion capture. Fragment gapping and rotation was quantified following 100 cycles at 10 N and again following 100 cycles at 500 N. RESULTS: No significant differences were detected between the 2.7 and 3.5 mm plates in fracture rotation or gapping following loads at 10 N (0.5° and 0.7°; 0.6 and 1.2 mm; respectively; p > 0.05) or 500 N (2.3° and 1.6°; 3.8 and 3.1 mm; respectively; p > 0.05) loading. Fragment rotation and gapping were positively correlated within each plate construct (R 2 > 0.445; p < 0.05). CONCLUSIONS: 2.7 mm plating is an alternative to 3.5 mm locked plating with decreased plate prominence without significantly sacrificing displacement and rotational control. This is beneficial in fracture patterns where the traditional dorsal plating does not offer optimal screw trajectory.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Olécrano , Fraturas da Ulna/cirurgia , Fenômenos Biomecânicos , Fixação Interna de Fraturas/métodos , Humanos , Modelos Biológicos , Olécrano/lesões , Olécrano/cirurgia , Amplitude de Movimento Articular
10.
Arch Orthop Trauma Surg ; 136(11): 1521-1529, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27568218

RESUMO

INTRODUCTION: The optimal treatment for distal clavicle nonunions remains unknown. Small series have reported outcomes following distal fragment excision and various fixation techniques. We present the clinical, radiographic and functional outcomes after superior plating or double (superior and anteroinferior) plating in combination with bone grafting as treatment for distal clavicle nonunions. METHODS: We collected demographic and radiographic data from a consecutive series of ten patients with symptomatic nonunion of the distal clavicle treated since 1998. Functional outcomes were assessed, as well as the visual analogue scale (VAS) score. RESULTS: The mean clinical follow-up was 41.4 months (range of 12-158 months). The mean radiological follow-up was 30.6 months (range of 3-158 months). All nonunions healed as demonstrated by subsidence of clinical symptoms and radiographic criteria. The average time to union was 3.7 months (range of 2-8 months). The mean The Disabilities of the Arm, Shoulder and Hand (DASH) score was 11.9 (range of 0-62.5) and mean VAS score was 0.9 at follow-up. CONCLUSION: This study illustrates good clinical, radiologic and functional outcomes in ten patients with distal clavicle nonunion treated with superior or double (superior and anteroinferior) plating in combination with bone grafting. Double-plating can be considered an alternative to superior plating offering better resistance against the pulling effect of the arm with the use of smaller fixation plates.


Assuntos
Placas Ósseas , Clavícula/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas não Consolidadas/cirurgia , Radiografia/métodos , Amplitude de Movimento Articular/fisiologia , Fraturas do Ombro/cirurgia , Adulto , Idoso , Clavícula/diagnóstico por imagem , Clavícula/lesões , Feminino , Seguimentos , Fraturas não Consolidadas/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas do Ombro/diagnóstico , Fraturas do Ombro/fisiopatologia , Fatores de Tempo , Adulto Jovem
11.
Arch Orthop Trauma Surg ; 136(1): 9-15, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26506829

RESUMO

INTRODUCTION: Ankle fractures are one of the most common fractures requiring surgical treatment. Ankle fracture-dislocations are significant injuries to the osseous and soft tissue envelope, but studies focused on the effect of dislocation on radiographic and functional outcomes are lacking. The objective of this study was to evaluate the effect of dislocations on postoperative outcomes in SER IV ankle fracture patients. MATERIALS AND METHODS: From 2004 through 2010, all operative SER IV ankle fractures treated by a single surgeon were enrolled in a prospective database. SER IV ankle fractures were separated into two groups based on clinical or radiographic evidence of dislocation. The primary and secondary functional outcomes measures were the Foot and Ankle Outcome Score (FAOS) and ankle and subtalar range of motion (ROM) with a minimum of 1-year follow-up, respectively. RESULTS: 108 patients with SER IV ankle fractures were identified, with 73 in the non-dislocation group (68%) and 35 patients in the dislocation group (32%). Patient demographics and co-morbidities were similar between the two groups. The incidence of open fractures and the application of an external fixator were significantly higher in the dislocation group (p = 0.037 and p = 0.003, respectively). The dislocation group showed a significant decrease in the accuracy of articular reduction (p = 0.003). At a mean follow-up of 21 months, ankle fracture-dislocation patients had increased pain (p = 0.005) and decreased activities of daily living (p = 0.014) on FAOS outcome measures and significantly worse ankle and subtalar ROM. CONCLUSIONS: The results of this study suggest that concurrent dislocation at time of ankle fracture is associated with worse radiographic and functional outcomes, but not an increase in superficial or deep infection. The results from this study may be helpful in counseling patients regarding expected clinical outcomes after ankle fracture-dislocation and in the surgical management of this complex injury.


Assuntos
Fraturas do Tornozelo/cirurgia , Articulação do Tornozelo/cirurgia , Fixação de Fratura , Luxações Articulares/complicações , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fraturas do Tornozelo/complicações , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/fisiopatologia , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/fisiologia , Estudos de Casos e Controles , Feminino , Seguimentos , Humanos , Luxações Articulares/diagnóstico por imagem , Luxações Articulares/cirurgia , Masculino , Pessoa de Meia-Idade , Radiografia , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Rotação , Supinação , Resultado do Tratamento , Adulto Jovem
12.
J Magn Reson Imaging ; 41(2): 550-4, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24338938

RESUMO

PURPOSE: To assess regional variations in the arterial and venous blood supply to the femoral head following displaced fracture of the femoral neck using dynamic contrast enhanced (DCE)-MRI quadrant analysis. MATERIALS AND METHODS: A total of 27 subjects with displaced femoral neck fractures were enrolled in the study. Quadrant specific DCE-MRI perfusion analysis was performed on a 1.5 Tesla MRI scanner. Simultaneous imaging of control and displaced fractured hips was done for comparison. RESULTS: Quadrant specific decreases were found in the arterial (A (0.52 versus 0.27; P = 5.7E-13), Akep (1.0/min(-1) versus 0.41/min(-1) ; P = 1.3E-9) and venous (kel (0.05/min(-1) versus -0.02/min(-1) ; P = 5.1E-5) supply to the femoral head between control and injured sides using a two-factor analysis of variance test. The fractional perfusion (initial area under the curve) in the supero/inferolateral quadrants was 49% min/54% min, in the supero/inferomedial quadrants was 43% min/46% min and for the total femoral head was 39% min on the fracture versus control sides. CONCLUSION: Quadrant specific decreases in arterial and venous perfusion on the fracture side were observed when compared with control.


Assuntos
Fraturas do Colo Femoral/complicações , Cabeça do Fêmur/irrigação sanguínea , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
13.
J Shoulder Elbow Surg ; 24(11): e307-11, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26341025

RESUMO

BACKGROUND: The radial nerve is at risk after diaphyseal humeral fracture or surgery to repair the fracture. We hypothesized that there are no factors associated with iatrogenic radial nerve palsy and, secondarily, that there are no factors associated with traumatic radial nerve palsy or radial nerve palsy of any type. METHODS: We analyzed 325 adult patients who underwent operative treatment of a diaphyseal humerus fracture at 6 hospitals between January 2002 and November 2014 to determine factors associated with a radial nerve palsy. We excluded patients with pathologic fractures, fractures with massive bone loss, prior surgery in another hospital, periprosthetic fractures, and if no operative note was available. RESULTS: In patients without a traumatic radial nerve palsy, an iatrogenic radial nerve palsy occurred in 18 of 259 diaphyseal humeral fractures (7%). The surgical approach was associated with iatrogenic radial nerve palsy (P = .034). No factors were associated with traumatic radial nerve palsy (66 of 325 patients [20%]) of the humeral diaphysis. Open fractures, location of fracture, and high-energy trauma were significantly associated with radial nerve palsy of any type (84 of 325 patients [26%]). CONCLUSIONS: Patients and surgeons should keep in mind that iatrogenic transient dysfunction of the radial nerve will occur in approximately 1 in 5 patients treated with lateral exposure of the humerus, in 1 in 9 patients treated with posterior exposure, and in 1 in 25 patients with an anterolateral exposure.


Assuntos
Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Fraturas do Úmero/cirurgia , Neuropatia Radial/etiologia , Adulto , Diáfises/lesões , Diáfises/cirurgia , Feminino , Fraturas Expostas/complicações , Fraturas Expostas/cirurgia , Humanos , Fraturas do Úmero/complicações , Doença Iatrogênica , Masculino , Pessoa de Meia-Idade
14.
Arch Orthop Trauma Surg ; 135(12): 1655-62, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26377733

RESUMO

BACKGROUND: We sought to evaluate clinical and biomechanical outcomes of dual mini-fragment plate fixation for clavicle fractures. We hypothesized that this technique would produce an anatomical reduction with good clinical outcomes, be well tolerated by patients, and demonstrate equivalent biomechanics to single plating. METHODS: Dual mini-fragment plating was performed for 17 isolated, displaced midshaft clavicle fractures. Functional outcomes and complications were retrospectively reviewed. A sawbones model compared dual plating biomechanics to a (1) superior 3.5-mm locking reconstruction plate, or (2) antero-inferior 3.5-mm locking reconstruction plate. RESULTS: On biomechanical testing, with anterior loading, dual plating was significantly more rigid than single locked anterior-plating (p = 0.02) but less rigid than single locked superior-plating (p = 0.001). With superior loading, dual plating trended toward higher rigidity versus single locked superior-plating (p = 0.07) but was less rigid than single locked anterior-plating (p = 0.03). No statistically significant differences in axial loading (p = 0.27) or torsion (p = 0.23) were detected. Average patient follow-up was 16.1 months (12-38). Anatomic reduction was achieved and maintained through final healing (average 14.7 weeks). No patient underwent hardware removal. Average 1-year DASH score was 4.0 (completed in 88 %). CONCLUSIONS: Displaced midshaft clavicle fractures can be effectively managed with dual mini-fragment plating. This technique results in high union rates and excellent clinical outcomes. Compared to single plating, dual plating is biomechanically equivalent in axial loading and torsion, yet offers better multi-planar bending stiffness despite the use of smaller plates. This technique may decrease the need for secondary surgery due to implant prominence and may aid in fracture reduction by buttressing butterfly fragments in two planes.


Assuntos
Traumatismos do Braço/cirurgia , Placas Ósseas , Clavícula/lesões , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Traumatismos do Braço/fisiopatologia , Fenômenos Biomecânicos , Clavícula/cirurgia , Desenho de Equipamento , Feminino , Fraturas Ósseas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Miniaturização , Estudos Retrospectivos
15.
Arch Orthop Trauma Surg ; 135(4): 473-80, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25708026

RESUMO

INTRODUCTION: Piriformis fossa entry antegrade femoral nailing is a common method for stabilizing diaphyseal femur fractures. However, clinically significant complications such as chronic hip pain, hip abductor weakness, heterotopic ossification and femoral head osteonecrosis have been reported. A recent cadaveric study found that piriformis entry nailing damaged either the deep branch of the medial femoral circumflex artery (MFCA) or its distal superior retinacular artery branches in 100% of specimens and therefore recommended against its use. However, no study has quantitatively assessed the effect of different femoral entry points on femoral head perfusion. MATERIALS AND METHODS: Twelve fresh-frozen cadaveric lower extremity specimens were randomly allocated to either piriformis fossa or trochanteric entry nailing using a 13-mm reamer. The contralateral hip served as an internal matched control. All specimens subsequently underwent gadolinium-enhanced fat-suppressed gradient-echo sequence MRI to assess femoral head perfusion. Gross dissection was also performed to assess MFCA integrity and distance to the opening reamer path. RESULTS: MRI quantification analysis revealed near full femoral head perfusion with no significant difference between the piriformis and trochanteric starting points (95 vs. 97%, p = 0.94). There was no observed damage to the deep MFCA in either group. The mean distance from the reamer path to the deep MFCA was 3.2 mm in the piriformis group compared to 18.5 mm in the trochanteric group (p = 0.001). Additionally, there was a significantly greater number of mean terminal superior retinacular vessels damaged by the opening reamer in the piriformis cohort (1 vs. 0; p = 0.007). CONCLUSIONS: No statistically significant difference in femoral head perfusion was found between the two groups. Therefore, we cannot recommend against the use of piriformis entry femoral nails. However, we caution against multiple errant starting point attempts and recommend meticulous soft tissue protection during the procedure.


Assuntos
Fraturas do Fêmur/terapia , Cabeça do Fêmur/cirurgia , Fixação Intramedular de Fraturas/métodos , Perfusão/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Cadáver , Feminino , Artéria Femoral , Fraturas do Fêmur/diagnóstico , Cabeça do Fêmur/irrigação sanguínea , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade
16.
J Foot Ankle Surg ; 54(4): 531-5, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25189335

RESUMO

Stress ankle radiographs are routinely performed to determine deep deltoid ligament integrity in supination external rotation (SER) ankle fractures. However, variability is present in the published data regarding what medial clear space (MCS) value constitutes a positive result. The purposes of the present study were to evaluate the diagnostic accuracy of different MCS cutoff values and determine whether this clinical test could accurately discriminate between patients with and without a deep deltoid ligament disruption. MCS measurements were recorded for stress ankle injury radiographs in an SER ankle fracture cohort. Preoperative ankle magnetic resonance imaging studies, obtained for all patients, were then read independently by 2 musculoskeletal attending radiologists to determine deep deltoid ligament integrity. The MCS measurements were compared with the magnetic resonance imaging diagnosis using receiver operating characteristic analyses to determine the sensitivity, specificity, and optimal data-driven cutoff values. SER II-III patients demonstrated a mean stress MCS distance of 4.3 ± 0.98 mm compared with 5.8 ± 1.76 mm in the SER IV cohort (p < .001). An analysis of differing MCS positive cutoff thresholds revealed that a stress MCS of 5.0 mm maximized the combined sensitivity and specificity of the external rotation test: 65.8% sensitive and 76.5% specific. Using the receiver operating characteristic curve analysis of the MCS measurement, the calculated area under the curve was 0.77, indicating inadequate discriminative ability for diagnosing SER pattern fractures with or without a deep deltoid ligament tear. Judicious use of additional diagnostic testing in patients with a stress MCS result between 4.0 mm and 5.5 mm is warranted.


Assuntos
Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/patologia , Ligamentos Articulares/lesões , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Ligamentos Articulares/diagnóstico por imagem , Ligamentos Articulares/patologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Radiografia , Reprodutibilidade dos Testes , Rotação , Sensibilidade e Especificidade , Supinação , Adulto Jovem
17.
J Am Acad Orthop Surg ; 22(5): 304-14, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24788446

RESUMO

Combined fractures of the acetabulum and pelvic ring are more common than previously believed, with an incidence as high as 15.7%. Recent series that include combined injuries indicate that the incidence of lateral compression and anteroposterior compression pelvic ring injuries is similar and that transverse and both-column acetabular fractures are the most common acetabular fracture patterns. Combined injuries most often are the result of high-energy mechanisms, and, compared with patients who present with isolated pelvic or acetabular injury, patients with combined injury typically have higher injury severity scores, higher transfusion requirements, and lower systolic blood pressure, with reported mortality rates of 1.5% to 13%. Treatment requires a multidisciplinary approach. The first priority is resuscitation following the Advanced Trauma Life Support protocols. Once the patient is stable, acetabular fractures and pelvic ring injuries should be assessed individually, and the most appropriate treatment for each should be outlined. These treatments should then be integrated to develop the most appropriate overall treatment strategy. Although outcomes data are available for isolated acetabulum and pelvic ring disruptions, no such data currently exist for combined injuries.


Assuntos
Acetábulo/lesões , Fraturas Ósseas/cirurgia , Traumatismo Múltiplo/cirurgia , Articulação Sacroilíaca/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/etiologia , Humanos , Prognóstico , Sínfise Pubiana/lesões , Articulação Sacroilíaca/lesões
18.
Arch Orthop Trauma Surg ; 134(12): 1661-6, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25337963

RESUMO

INTRODUCTION: Posterior malleolus and other articular ankle injuries are known to concomitantly occur with tibial shaft fractures, especially spiral fractures of the distal one-third diaphysis. Due to our heightened awareness of this combined injury, our department instituted a new preoperative ankle imaging protocol for all distal one-third spiral tibia shaft fractures. The purpose of this study was to evaluate the effectiveness of an imaging protocol involving radiographs, CT and magnetic resonance imaging (MRI) in a distal one-third spiral tibia fracture cohort. MATERIALS AND METHODS: All operatively treated patients with a spiral distal one-third tibial shaft fracture from February 2012 to March 2013 underwent a standardized ankle imaging protocol. Patients had preoperative orthogonal ankle radiographs as well as a CT scan of the tibia that included the ankle. All ankle imaging was scrutinized for evidence of an ankle injury. If no ankle fracture was identified, patients would then undergo an ankle MRI. RESULTS: Twenty-five patients met the inclusion and exclusion criteria for this study. Concomitant osseous ankle injuries were identified by radiograph and CT in 56 % (14/25) of cases. The remaining 44 % (11/25) of patients had no evidence of a combined injury by radiograph or CT and therefore underwent an MRI. Of the MRI cohort, 64 % (7/11) were found to have an occult ankle fracture. The overall incidence of a combined injury using our protocol was 84 % (21/25). Identification of an occult injury led to a change in management for all of these patients. CONCLUSIONS: Concomitant ipsilateral ankle and distal one-third spiral tibial shaft fractures are more common than previously reported. Utilizing a new imaging protocol, we found that the incidence of this combined injury was 84 %. Recognition of the ankle fracture component in this tibial shaft cohort can be important as it may alter the surgical plan and postoperative management.


Assuntos
Fraturas do Tornozelo/complicações , Traumatismo Múltiplo/diagnóstico , Traumatismo Múltiplo/cirurgia , Fraturas da Tíbia/complicações , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/cirurgia , Articulação do Tornozelo/diagnóstico por imagem , Protocolos Clínicos , Diagnóstico por Imagem , Feminino , Humanos , Ligamentos Articulares/lesões , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Ossos do Tarso/diagnóstico por imagem , Tíbia/diagnóstico por imagem , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
19.
J Foot Ankle Surg ; 53(4): 434-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24795207

RESUMO

Associations between Weber C ankle fractures and pronation external rotation (PER) injuries of the Lauge-Hansen classification have often been incorrectly correlated. The purpose of the present study was to evaluate the Lauge-Hansen designation of Weber C fractures by establishing the proportion of Weber C fractures that are supination external rotation (SER), supination adduction (SA), pronation abduction (PA), PER, and hyperplantarflexion variant fractures. A clinical database of operative ankle fractures treated by the senior author (D.G.L.) was reviewed. The inclusion criteria were patient age older than 16 years, preoperative ankle radiographs, and Weber C fracture designation. A total of 132 patients met the inclusion criteria, and the proportion of PA, PER, SER, SA, and variant fractures among the Weber C fractures was analyzed. PA fractures accounted for 0.8% (n = 1), PER fractures 56.8% (n = 75), SER fractures 35.6% (n = 47), and hyperplantarflexion variant fractures 6.8% (n = 9) of the 132 Weber C fractures. Patients with Weber C-PER fractures were more commonly male (p = .005) and younger (p = .003) and demonstrated a greater fibular fracture height (p < .001) than those with Weber C-SER and Weber C-variant fractures. Our study quantitatively demonstrated that not all Weber C fractures occur secondary to pronation injuries. This distinction is important, because all pronation injuries will demonstrate medial ankle injury, but SER and variant fractures might not. We therefore recommend careful evaluation of the fibular fracture characteristics, including the direction of fracture propagation and the distance from the tibial plafond, when classifying Weber C fractures using the Lauge-Hansen system, because correct classification is vital in preparation for appropriate operative treatment.


Assuntos
Fraturas do Tornozelo/classificação , Fíbula/lesões , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/etiologia , Feminino , Fíbula/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Pronação , Radiografia , Supinação , Adulto Jovem
20.
Eur J Orthop Surg Traumatol ; 24(6): 953-60, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23887826

RESUMO

INTRODUCTION: The 95-degree-fixed angle blade plate has been in use for decades for both acute femoral fractures and nonunions. Our objective was to examine the results of use by a single surgeon of the 95-degree-angled blade plate in proximal and distal femoral nonunion surgery. PATIENTS AND METHODS: The nonunion database of a single surgeon over a 16 year period was used to identify all proximal and distal femoral nonunions that were treated with open reduction and internal fixation using the 95-degree-angled blade plate. There were 78 cases in which the blade plate was used, and 68 of 78 (87.2 % follow-up rate) were followed to a final outcome, which was defined as complete healing of the nonunion, conversion to arthroplasty, or amputation. Failure was defined as revision surgery for persistence of nonunion, conversion to arthroplasty prior to healing, or amputation. Three patients who failed were lost to follow-up prior to a final outcome. RESULTS: In the 71 patients who were followed to failure or complete follow-up, the rate of healing with one surgery was 77.5 % (55 of 71). Eight of 16 failures required a second surgery for persistence of nonunion and eventually went on to heal the nonunion. Eleven of the 16 failures were in patients who had a known infected nonunion. When the 21 cases of infected nonunions were excluded, the healing rate for aseptic nonunions with one surgery alone using the 95-degree-angled blade plate was 91.2 % (52 of 57) compared with 47.6 % (10 of 21) in the infected nonunion group (p < 0.0001). Eleven patients who had healed their nonunion underwent all or partial removal of the implant for irritation or prominence. CONCLUSION: The 95-degree-angled blade plate is an effective reduction aid and fixation device for aseptic nonunions of the proximal and distal femur with acceptable healing rates with one surgery alone.


Assuntos
Placas Ósseas , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/instrumentação , Consolidação da Fratura , Fraturas não Consolidadas/cirurgia , Infecção da Ferida Cirúrgica/complicações , Adulto , Idoso , Idoso de 80 Anos ou mais , Placas Ósseas/efeitos adversos , Remoção de Dispositivo , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Falha de Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA