Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Anal Chem ; 86(6): 2909-16, 2014 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-24521423

RESUMO

A benchtop miniature mass spectrometer system, Mini 12, with ambient ionization source and tandem mass spectrometry capabilities has been developed and characterized. This instrument was developed as a self-contained system to produce quantitative results for unprocessed samples of small volumes including nonvolatile analytes. The ion processing system, vacuum system, and control system are detailed. An integrated sample loading system facilitates automated operation. A user interface has been developed to acquire and to interpret analytical results for personnel who have limited mass spectrometry knowledge. Peak widths of Δm/z 0.6 Th (full width at half-maximum) and a mass range of up to m/z 900 are demonstrated with the rectilinear ion trap mass analyzer. Multistage experiments up to MS(5) are accomplished. Consumable cartridges have been designed for use in ambient paper spray ionization, and the recently developed extraction spray ionization method has been employed to improve the quantitative performance. Monitoring of trace-levels of chemicals in therapeutic drugs, as well as in food safety and environmental protection operations is demonstrated. Dual MS/MS scans are implemented to obtain the intensities of the fragment ions from the analyte and its internal standard, and the ratio is used in quantitative analysis of complex samples. Limits of quantitation (LOQ) of 7.5 ng/mL, with relative standard deviations below 10%, have been obtained for selected therapeutic drugs in whole blood throughout their individual therapeutic ranges.


Assuntos
Espectrometria de Massas/métodos , Miniaturização , Limite de Detecção
2.
Anal Chem ; 86(12): 6121-9, 2014 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-24906177

RESUMO

We report the development of a method coupling microfluidics and a miniature mass spectrometer, applied to quantitation of drugs of abuse in urine. A custom digital microfluidic system was designed to deliver droplets of solvent to dried urine samples and then transport extracted analytes to an array of nanoelectrospray emitters for analysis. Tandem mass spectrometry (MS/MS) detection was performed using a fully autonomous 25 kg instrument. Using the new method, cocaine, benzoylecgonine, and codeine can be quantified from four samples in less than 15 min from (dried) sample to analysis. The figures of merit for the new method suggest that it is suitable for on-site screening; for example, the limit of quantitation (LOQ) for cocaine is 40 ng/mL, which is compatible with the performance criteria for laboratory analyses established by the United Nations Office on Drugs and Crime. More importantly, the LOQ of the new method is superior to the 300 ng/mL cutoff values used by the only other portable analysis systems we are aware of (relying on immunoassays). This work serves as a proof-of-concept for integration of microfluidics with miniature mass spectrometry. The system is attractive for the quantitation of drugs of abuse from urine and, more generally, may be useful for a wide range of applications that would benefit from portable, quantitative, on-site analysis.


Assuntos
Drogas Ilícitas/urina , Microfluídica/métodos , Espectrometria de Massas em Tandem/métodos , Humanos , Limite de Detecção
3.
Anal Chem ; 86(6): 2900-8, 2014 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-24521448

RESUMO

A major design objective of portable mass spectrometers is the ability to perform in situ chemical analysis on target samples in their native states in the undisturbed environment. The miniature instrument described here is fully contained in a wearable backpack (10 kg) with a geometry-independent low-temperature plasma (LTP) ion source integrated into a hand-held head unit (2 kg) to allow direct surface sampling and analysis. Detection of chemical warfare agent (CWA) simulants, illicit drugs, and explosives is demonstrated at nanogram levels directly from surfaces in near real time including those that have complex geometries, those that are heat-sensitive, and those bearing complex sample matrices. The instrument consumes an average of 65 W of power and can be operated autonomously under battery power for ca. 1.5 h, including the initial pump-down of the manifold. The maximum mass-to-charge ratio is 925 Th with mass resolution of 1-2 amu full width at half-maximun (fwhm) across the mass range. Multiple stages of tandem analysis can be performed to identify individual compounds in complex mixtures. Both positive and negative ion modes are available. A graphical user interface (GUI) is available for novice users to facilitate data acquisition and real-time spectral matching.


Assuntos
Espectrometria de Massas/métodos , Miniaturização , Software , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA