Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Ultrasound Med ; 43(1): 109-114, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37772458

RESUMO

OBJECTIVES: Shear wave elastography (SWE) is increasingly used in breast cancer diagnostics. However, large, prospective, multicenter data evaluating the reliability of SWE is missing. We evaluated the intra- and interobserver reliability of SWE in patients with breast lesions categorized as BIRADS 3 or 4. METHODS: We used data of 1288 women at 12 institutions in 7 countries with breast lesions categorized as BIRADS 3 to 4 who underwent conventional B-mode ultrasound and SWE. 1243 (96.5%) women had three repetitive conventional B-mode ultrasounds as well as SWE measurements performed by a board-certified senior physician. 375 of 1288 (29.1%) women received an additional ultrasound examination with B-mode and SWE by a second physician. Intraclass correlation coefficients (ICC) were calculated to examine intra- and interobserver reliability. RESULTS: ICC for intraobserver reliability showed an excellent correlation with ICC >0.9, while interobserver reliability was moderate with ICC of 0.7. There were no clinically significant differences in intraobserver reliability when SWE was performed in lesions categorized as BI-RADS 3 or 4 as well as in histopathologically benign or malignant lesions. CONCLUSION: Reliability of additional SWE was evaluated on a study cohort consisting of 1288 breast lesions categorized as BI-RADS 3 and 4. SWE shows an excellent intraobserver reliability and a moderate interobserver reliability in the evaluation of solid breast masses.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Humanos , Feminino , Masculino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Ultrassonografia Mamária , Estudos Prospectivos , Reprodutibilidade dos Testes , Mama/diagnóstico por imagem , Mama/patologia , Sensibilidade e Especificidade , Diagnóstico Diferencial
2.
Arch Gynecol Obstet ; 309(6): 2771-2778, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38625545

RESUMO

PURPOSE: The primary objective of this study was to establish a benchmark by collecting baseline data on surgical education in obstetrics and gynecology in Germany, including factual number of operations performed. MATERIALS AND METHODS: A nationwide anonymous survey was conducted in Germany between January 2019 and July 2019 utilizing a specially designed questionnaire which addressed both residents and senior trainers. RESULTS: A total of 601 participants completed the survey, comprising 305 trainees and 296 trainers. The trainees reported performing a median of 125 non-obstetric surgeries (IQR: 41-332) and 75 obstetric procedures (IQR: 27-168) independently. While most last-year residents managed to meet the targeted numbers for minor surgical procedures outlined in the logbook, they fell short of achieving the required numbers for major operations, such as hysterectomies or more complex laparoscopies. Although both trainees and trainers emphasized the significance of surgical training, the overall quality of the training was rated poorly, particularly by trainees. This was attributed to a high proportion of administrative tasks and a deficiency in teaching time within the operating theater. External fellowship and mentoring programs, as well as the implementation of regular, centralized reviews of residency training, were identified as potentially beneficial by both trainees and trainers. CONCLUSION: The findings of this survey should serve as a wake-up call both within and outside of Germany, highlighting the importance of comprehensive and structured surgical training to enhance long-term patient care and increase satisfaction among obstetrics and gynecology trainees.


Assuntos
Ginecologia , Internato e Residência , Obstetrícia , Humanos , Obstetrícia/educação , Alemanha , Internato e Residência/estatística & dados numéricos , Ginecologia/educação , Feminino , Inquéritos e Questionários , Masculino , Adulto , Procedimentos Cirúrgicos em Ginecologia/educação , Procedimentos Cirúrgicos em Ginecologia/estatística & dados numéricos , Competência Clínica/estatística & dados numéricos , Pessoa de Meia-Idade
3.
Breast Cancer Res Treat ; 201(1): 57-66, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37302085

RESUMO

PURPOSE: A previous study in our breast unit showed that the diagnostic accuracy of intraoperative specimen radiography and its potential to reduce second surgeries in a cohort of patients treated with neoadjuvant chemotherapy were low, which questions the routine use of Conventional specimen radiography (CSR) in this patient group. This is a follow-up study in a larger cohort to further evaluate these findings. METHODS: This retrospective study included 376 cases receiving breast-conserving surgery (BCS) after neoadjuvant chemotherapy (NACT) of primary breast cancer. CSR was performed to assess potential margin infiltration and recommend an intraoperative re-excision of any radiologically positive margin. The histological workup of the specimen served as gold standard for the evaluation of the accuracy of CSR and the potential reduction of second surgeries by CSR-guided re-excisions. RESULTS: 362 patients with 2172 margins were assessed. The prevalence of positive margins was 102/2172 (4.7%). CSR had a sensitivity of 37.3%, a specificity of 85.6%, a positive predictive value (PPV) of 11.3%, and a negative predictive value (NPV) of 96.5%. The rate of secondary procedures was reduced from 75 to 37 with a number needed to treat (NNT) of CSR-guided intraoperative re-excisions of 10. In the subgroup of patients with clinical complete response (cCR), the prevalence of positive margins was 38/1002 (3.8%), PPV was 6.5% and the NNT was 34. CONCLUSION: This study confirms our previous finding that the rate of secondary surgeries cannot be significantly reduced by CSR-guided intraoperative re-excisions in cases with cCR after NACT. The routine use CSR after NACT is questionable, and alternative tools of intraoperative margin assessment should be evaluated.


Assuntos
Neoplasias da Mama , Carcinoma Ductal de Mama , Humanos , Feminino , Terapia Neoadjuvante/métodos , Seguimentos , Estudos Retrospectivos , Carcinoma Ductal de Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/cirurgia , Mastectomia Segmentar/métodos , Margens de Excisão , Radiografia
4.
J Ultrasound Med ; 42(8): 1729-1736, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36789976

RESUMO

OBJECTIVES: We evaluated whether lesion-to-fat ratio measured by shear wave elastography in patients with Breast Imaging Reporting and Data System (BI-RADS) 3 or 4 lesions has the potential to further refine the assessment of B-mode ultrasound alone in breast cancer diagnostics. METHODS: This was a secondary analysis of an international diagnostic multicenter trial (NCT02638935). Data from 1288 women with breast lesions categorized as BI-RADS 3 and 4a-c by conventional B-mode ultrasound were analyzed, whereby the focus was placed on differentiating lesions categorized as BI-RADS 3 and BI-RADS 4a. All women underwent shear wave elastography and histopathologic evaluation functioning as reference standard. Reduction of benign biopsies as well as the number of missed malignancies after reclassification using lesion-to-fat ratio measured by shear wave elastography were evaluated. RESULTS: Breast cancer was diagnosed in 368 (28.6%) of 1288 lesions. The assessment with conventional B-mode ultrasound resulted in 53.8% (495 of 1288) pathologically benign lesions categorized as BI-RADS 4 and therefore false positives as well as in 1.39% (6 of 431) undetected malignancies categorized as BI-RADS 3. Additional lesion-to-fat ratio in BI-RADS 4a lesions with a cutoff value of 1.85 resulted in 30.11% biopsies of benign lesions which correspond to a reduction of 44.04% of false positives. CONCLUSIONS: Adding lesion-to-fat ratio measured by shear wave elastography to conventional B-mode ultrasound in BI-RADS 4a breast lesions could help reduce the number of benign biopsies by 44.04%. At the same time, however, 1.98% of malignancies were missed, which would still be in line with American College of Radiology BI-RADS 3 definition of <2% of undetected malignancies.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Humanos , Feminino , Sensibilidade e Especificidade , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia Mamária/métodos , Reprodutibilidade dos Testes , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Biópsia , Elasticidade , Diagnóstico Diferencial
5.
Arch Gynecol Obstet ; 308(1): 219-229, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36604331

RESUMO

PURPOSE: Today, the decision to treat patients with chemotherapy for early breast cancer (EBC) is made based on the patient's individual risk stratification and tumor biology. In cases with chemotherapy indication, the neoadjuvant application (NACT) is the preferred option in comparison with primary surgery and adjuvant chemotherapy (ACT). Age remains a relevant factor in the decision-making process. The aim of the present study was to illustrate the impact of age on the use of systemic therapy in clinical routine. METHODS: The study separately analyzed chemotherapy use among six age cohorts of EBC patients who had been treated at 104 German breast units between January 2008 and December 2017. RESULTS: In total, 124,084 patients were included, 46,279 (37.3%) of whom had received chemotherapy. For 44,765 of these cases, detailed information on treatment was available. Within this cohort, chemotherapy was administered as NACT to 14,783 patients (33.0%) and as ACT to 29,982 (67.0%) patients. Due to the higher prevalence of unfavorable tumor subtypes, younger patients had a higher rate of chemotherapy (≤ 29y: 74.2%; 30-39y: 71.3%) and a higher proportion of NACT administration ( ≤ 29y: 66.9%; 30-39y: 56.0%) in comparison with elderly patients, who had lower rates for overall chemotherapy (60-69y: 37.5%; ≥ 70y: 17.6%) and NACT (60-69y: 25.5%; ≥ 70y: 22.8%). Pathologic complete response was higher in younger than in older patients (≤ 29y: 30.4% vs. ≥ 70y: 16.7%), especially for HER2- subtypes. CONCLUSION: The data from the nationwide German cohort reveal relevant age-dependent discrepancies concerning the use of chemotherapy for EBC.


Assuntos
Neoplasias da Mama , Humanos , Idoso , Feminino , Neoplasias da Mama/patologia , Quimioterapia Adjuvante , Terapia Neoadjuvante/métodos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos
6.
Arch Gynecol Obstet ; 307(4): 1105-1113, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35980458

RESUMO

PURPOSE: Breast cancer (BC) is the most common malignancy among women and prognosis is strongly influenced by tumor subtype. Neoadjuvant chemotherapy (NAC) is the standard treatment for both locally advanced- and early-stage triple-negative and Her2-positive BC. Pathologic complete response (pCR) to NAC is an important predictor of patient outcomes. Neutrophil-to-lymphocyte-ratio (NLR) in peripheral blood is associated with prognosis in various malignancies. Here, we investigated the value of the pretreatment NLR as a response predictor in neoadjuvant-treated patients with BC. METHODS: A retrospective chart analysis of 862 patients with invasive BC treated with NAC at the Heidelberg University Hospital during 2003-2015 was conducted. NLR was calculated as the ratio of the absolute neutrophil and lymphocyte counts in peripheral blood, and pCR was defined as absence of invasive or in situ carcinoma in breast and axillary lymph nodes. RESULTS: A total of 151 patients with invasive BC who underwent NAC were included in this study. NLR tended to be higher in the pCR group than the non-pCR group (p < 0.1). Analyses of BC subtypes demonstrated that NLR was significantly higher in the pCR- compared with the non-pCR group (3.304 vs. 2.379, respectively; p = 0.048) in patients with luminal B/Her2-negative tumors. Further, we found a significant difference in NLR according to remission status in postmenopausal patients (2.861 vs. 2.313, respectively; p = 0.043). CONCLUSION: NLR was significantly higher only for patients achieving pCR in the Luminal B/Her2-negative and postmenopausal subgroups. Hence, NLR is a candidate additional predictive factor in patients with Luminal B/Her2-negative BC.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Neutrófilos/patologia , Terapia Neoadjuvante , Estudos Retrospectivos , Linfócitos/patologia , Prognóstico , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Receptor ErbB-2
7.
Breast Cancer Res Treat ; 191(3): 589-598, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34878635

RESUMO

PURPOSE: This is the first study to systematically evaluate the diagnostic accuracy of intraoperative specimen radiography on margin level and its potential to reduce second surgeries in patients treated with neoadjuvant chemotherapy. METHODS: This retrospective study included 174 cases receiving breast conserving surgery (BCS) after neoadjuvant chemotherapy (NACT) of primary breast cancer. Conventional specimen radiography (CSR) was performed to assess potential margin infiltration and recommend an intraoperative re-excision of any radiologically positive margin. The histological workup of the specimen served as gold standard for the evaluation of the accuracy of CSR and the potential reduction of second surgeries by CSR-guided re-excisions. RESULTS: 1044 margins were assessed. Of 47 (4.5%) histopathological positive margins, CSR identified 9 correctly (true positive). 38 infiltrated margins were missed (false negative). This resulted in a sensitivity of 19.2%, a specificity of 89.2%, a positive predictive value (PPV) of 7.7%, and a negative predictive value (NPV) of 95.9%. The rate of secondary procedures was reduced from 23 to 16 with a number needed to treat (NNT) of CSR-guided intraoperative re-excisions of 25. In the subgroup of patients with cCR, the prevalence of positive margins was 10/510 (2.0%), PPV was 1.9%, and the NNT was 85. CONCLUSION: Positive margins after NACT are rare and CSR has only a low sensitivity to detect them. Thus, the rate of secondary surgeries cannot be significantly reduced by recommending targeted re-excisions, especially in cases with cCR. In summary, CSR after NACT is inadequate for intraoperative margin assessment but remains useful to document removal of the biopsy site clip.


Assuntos
Neoplasias da Mama , Carcinoma Ductal de Mama , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/cirurgia , Feminino , Humanos , Mastectomia Segmentar , Terapia Neoadjuvante , Radiografia , Estudos Retrospectivos
8.
Eur Radiol ; 32(6): 4101-4115, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35175381

RESUMO

OBJECTIVES: AI-based algorithms for medical image analysis showed comparable performance to human image readers. However, in practice, diagnoses are made using multiple imaging modalities alongside other data sources. We determined the importance of this multi-modal information and compared the diagnostic performance of routine breast cancer diagnosis to breast ultrasound interpretations by humans or AI-based algorithms. METHODS: Patients were recruited as part of a multicenter trial (NCT02638935). The trial enrolled 1288 women undergoing routine breast cancer diagnosis (multi-modal imaging, demographic, and clinical information). Three physicians specialized in ultrasound diagnosis performed a second read of all ultrasound images. We used data from 11 of 12 study sites to develop two machine learning (ML) algorithms using unimodal information (ultrasound features generated by the ultrasound experts) to classify breast masses which were validated on the remaining study site. The same ML algorithms were subsequently developed and validated on multi-modal information (clinical and demographic information plus ultrasound features). We assessed performance using area under the curve (AUC). RESULTS: Of 1288 breast masses, 368 (28.6%) were histopathologically malignant. In the external validation set (n = 373), the performance of the two unimodal ultrasound ML algorithms (AUC 0.83 and 0.82) was commensurate with performance of the human ultrasound experts (AUC 0.82 to 0.84; p for all comparisons > 0.05). The multi-modal ultrasound ML algorithms performed significantly better (AUC 0.90 and 0.89) but were statistically inferior to routine breast cancer diagnosis (AUC 0.95, p for all comparisons ≤ 0.05). CONCLUSIONS: The performance of humans and AI-based algorithms improves with multi-modal information. KEY POINTS: • The performance of humans and AI-based algorithms improves with multi-modal information. • Multimodal AI-based algorithms do not necessarily outperform expert humans. • Unimodal AI-based algorithms do not represent optimal performance to classify breast masses.


Assuntos
Inteligência Artificial , Neoplasias da Mama , Algoritmos , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Feminino , Humanos , Imagem Multimodal
9.
J Ultrasound Med ; 41(2): 427-436, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33942358

RESUMO

OBJECTIVES: The BI-RADS classification provides a standardized way to describe ultrasound findings in breast cancer diagnostics. However, there is little information regarding which BI-RADS descriptors are most strongly associated with malignancy, to better distinguish BI-RADS 3 (follow-up imaging) and 4 (diagnostic biopsy) breast masses. METHODS: Patients were recruited as part of an international, multicenter trial (NCT02638935). The trial enrolled 1294 women (6 excluded) categorized as BI-RADS 3 or 4 upon routine B-mode ultrasound examination. Ultrasound images were evaluated by three expert physicians according to BI-RADS. All patients underwent histopathological confirmation (reference standard). We performed univariate and multivariate analyses (chi-square test, logistic regression, and Krippendorff's alpha). RESULTS: Histopathologic evaluation showed malignancy in 368 of 1288 masses (28.6%). Upon performing multivariate analysis, the following descriptors were significantly associated with malignancy (P < .05): age ≥50 years (OR 8.99), non-circumscribed indistinct (OR 4.05) and microlobulated margin (OR 2.95), nonparallel orientation (OR 2.69), and calcification (OR 2.64). A clinical decision rule informed by these results demonstrated a 97% sensitivity and missed fewer cancers compared to three physician experts (range of sensitivity 79-95%) and a previous decision rule (sensitivity 59%). Specificity was 44% versus 22-83%, respectively. The inter-reader reliability of the BI-RADS descriptors and of the final BI-RADS score was fair-moderate. CONCLUSIONS: A patient should undergo a diagnostic biopsy (BI-RADS 4) instead of follow-up imaging (BI-RADS 3) if the patient is 50 years or older or exhibits at least one of the following features: calcification, nonparallel orientation of mass, non-circumscribed margin, or posterior shadowing.


Assuntos
Neoplasias da Mama , Ultrassonografia Mamária , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Ultrassonografia
10.
Arch Gynecol Obstet ; 306(5): 1587-1596, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35852646

RESUMO

PURPOSE: The aim of this study was to investigate whether students' attitude towards online learning in Gynecology and Obstetrics changed during the COVID-19 pandemic. We further examined which variables impacted students' satisfaction with digital learning. METHODS: A specifically developed questionnaire was used from June 2020-July 2021 for N = 234 medical students participating in the course "Gynecology and Obstetrics" at University of Heidelberg. Thirty-five items were repeatedly applied in different cohorts to assess structure- and content-related quality of teaching. In addition, their influence on overall satisfaction with digital teaching was analyzed by applying investigative analyses like multiple regression and extreme group comparisons. RESULTS: Especially items associated with content-related quality of teaching (ß = 0.24), organization of teaching (ß = 0.25) and subjective learning success (ß = 0.27) seemed to be relevant predictors for overall satisfaction with courses. Fears and changes due to the pandemic situation also played a role for a subgroup of students. Aspects linked to technical quality of teaching, interactions with teachers and students or advantages of web-based learning appeared to play a subordinate role for overall satisfaction with digital teaching. Comparisons of ratings over time revealed that teaching evaluations almost remained the same. CONCLUSION: Our results give several hints regarding how digital teaching should be designed and how it can be improved. Further studies are needed to validate our results and to develop methods to improve digital teaching in medicine.


Assuntos
COVID-19 , Ginecologia , Obstetrícia , Estudantes de Medicina , Feminino , Ginecologia/educação , Humanos , Obstetrícia/educação , Pandemias , Satisfação Pessoal , Gravidez , Ensino
11.
Arch Gynecol Obstet ; 305(1): 129-137, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34550446

RESUMO

PURPOSE: The field of obstetrics and gynecology (OB/GYN) is facing growing competition for young professionals in Germany, with high interest rates among female graduates and a declining proportion of male students who choose residency training in the field. The aim of this study is to analyze general and gender-dependent factors that influence the decision for or against specialty training in OB/GYN among medical students in Germany. METHODS: Between February and November 2019, n = 346 medical students in their 5th and 6th year of undergraduate training at Heidelberg University received a questionnaire with 44 items. RESULTS: n = 286 students (61.3 female; 38.7% male) participated in the study. 28% of the female students and 9% of the male students had considered OB/GYN for their specialty training. The students reported different general and gender-specific influencing factors in their choice of a specialty. Both genders desired a good work-life-balance, however, in comparison with their female colleagues, male students had heavily weighted factors related to their later careers and professional success, including competition among colleagues. Male students had gained little practical experience during compulsory internships (26.9% for females vs. 8.8% for males) or had chosen their final-year elective in OB/GYN (15.9% for females vs. 5.5% for males). Female students had worried about the negative effects of their sex on their career (35.4% for females vs. 5.9% for males). CONCLUSION: OB/GYN must become more appealing and attractive to young female and male professionals alike. A better compatibility of career and family should go hand in hand with the implementation of differentiated, (extra) curricular teaching approaches that take the different preferences of female and male students into account.


Assuntos
Ginecologia , Internato e Residência , Obstetrícia , Estudantes de Medicina , Feminino , Alemanha , Ginecologia/educação , Humanos , Masculino , Obstetrícia/educação , Gravidez , Inquéritos e Questionários
12.
Ann Surg Oncol ; 28(13): 8742-8751, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34279753

RESUMO

BACKGROUND: Poor patient-reported satisfaction after breast-conserving therapy (BCT) has been associated with impaired health-related quality of life (HRQOL) and subsequent depression in retrospective analysis. This prospective cohort study aimed to assess the HRQOL of patients who have undergone BCT using the BREAST-Q, and to identify clinical risk factors for lower patient satisfaction. METHODS: Patients with primary breast cancer undergoing BCT were asked to complete the BREAST-Q preoperatively (T1) for baseline evaluation, then 3 to 4 weeks postoperatively (T2), and finally 1 year after surgery (T3). Clinicopathologic data were extracted from the patients' charts. Repeated measures analysis of variance (ANOVA) was used to determine significant differences in mean satisfaction and well-being levels among the test intervals. Multiple linear regression was used to evaluate risk factors for lower satisfaction. RESULTS: The study enrolled 250 patients. The lowest baseline BREAST-Q score was reported for "satisfaction with breast" (mean, 61 ± 19), but this increased postoperatively (mean, 66 ± 18) and was maintained at the 1 year follow-up evaluation (mean, 67 ± 21). "Physical well-being" decreased from T1 (mean, 82 ± 17) to T2 (mean, 28 ± 13) and did not recover much by T3 (mean, 33 ± 13), being the lowest BREAST-Q score postoperatively and in the 1-year follow-up evaluation. In multiple regression, baseline psychosocial well-being, body mass index (BMI), and type of incision were risk factors for lower "satisfaction with breasts." CONCLUSION: Both the aesthetic/surgery-related and psychological aspects are equally important with regard to "satisfaction with breasts" after BCT. The data could serve as the benchmark for future studies.


Assuntos
Satisfação do Paciente , Qualidade de Vida , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Inquéritos e Questionários
13.
Eur Radiol ; 31(6): 3712-3720, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33313983

RESUMO

OBJECTIVE: The FUSION-X-US-II prototype was developed to combine 3D automated breast ultrasound (ABUS) and digital breast tomosynthesis in a single device. We evaluated the performance of ABUS and tomosynthesis in a single examination in a clinical setting. METHODS: In this prospective feasibility study, digital breast tomosynthesis and ABUS were performed using the FUSION-X-US-II prototype without any change of the breast position in patients referred for clarification of breast lesions with an indication for tomosynthesis. The tomosynthesis and ABUS images of the prototype were interpreted independently from the clinical standard by a breast diagnostics specialist. Any detected lesion was classified using BI-RADS® scores, and results of the standard clinical routine workup (gold standard) were compared to the result of the separate evaluation of the prototype images. Image quality was rated subjectively and coverage of the breast was measured. RESULTS: One hundred one patients received both ABUS and tomosynthesis using the prototype. The duration of the additional ABUS acquisition was 40 to 60 s. Breast coverage by ABUS was approximately 80.0%. ABUS image quality was rated as diagnostically useful in 86 of 101 cases (85.1%). Thirty-three of 34 malignant breast lesions (97.1%) were identified using the prototype. CONCLUSION: The FUSION-X-US-II prototype allows a fast ABUS scan in combination with digital breast tomosynthesis in a single device integrated in the clinical workflow. Malignant breast lesions can be localized accurately with direct correlation of ABUS and tomosynthesis images. The FUSION system shows the potential to improve breast cancer screening in the future after further technical improvements. KEY POINTS: • The FUSION-X-US-II prototype allows the combination of automated breast ultrasound and digital breast tomosynthesis in a single device without decompression of the breast. • Image quality and coverage of ABUS are sufficient to accurately detect malignant breast lesions. • If tomosynthesis and ABUS should become part of breast cancer screening, the combination of both techniques in one device could offer practical and logistic advantages. To evaluate a potential benefit of a combination of ABUS and tomosynthesis in screening-like settings, further studies are needed.


Assuntos
Neoplasias da Mama , Ultrassonografia Mamária , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Mamografia , Estudos Prospectivos , Sensibilidade e Especificidade
14.
Arch Gynecol Obstet ; 304(2): 559-566, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33970324

RESUMO

PURPOSE: The FUSION-X-US-II prototype was developed to combine 3D-automated breast ultrasound (ABUS) and digital breast tomosynthesis in a single device without decompressing the breast. We evaluated the technical function, feasibility of the examination workflow, image quality, breast tissue coverage and patient comfort of the ABUS device of the new prototype. METHODS: In this prospective feasibility study, the FUSION-X-US-II prototype was used to perform ABUS in 30 healthy volunteers without history of breast cancer. The ABUS images of the prototype were interpreted by a physician with specialization in breast diagnostics. Any detected lesions were measured and classified using BI-RADS® scores. Image quality was rated subjectively by the physician and coverage of the breast was measured. Patient comfort was evaluated by a questionnaire after the examination. RESULTS: One hundred and six scans were performed (61 × CC, 23 × ML, 22 × MLO) in 60 breasts. Image acquisition and processing by the prototype was fast and accurate. Breast coverage by ABUS was approximately 90.8%. Sixteen breast lesions (all benign, classified as BIRADS® 2) were identified. The examination was tolerated by all patients. CONCLUSION: The FUSION-X-US-II prototype allows a rapid ABUS scan with mostly high patient comfort. Technical developments resulted in an improvement of quality and coverage compared to previous prototype versions. The results are encouraging for a test of the prototype in a clinical setting in combination with tomosynthesis.


Assuntos
Mama/diagnóstico por imagem , Diagnóstico por Computador/instrumentação , Mamografia/instrumentação , Imagem Multimodal/instrumentação , Ultrassonografia Mamária/instrumentação , Adulto , Neoplasias da Mama/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Voluntários Saudáveis , Humanos , Mamografia/métodos , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Estudo de Prova de Conceito , Estudos Prospectivos , Ultrassonografia Mamária/métodos
15.
BMC Med Educ ; 21(1): 209, 2021 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-33849503

RESUMO

BACKGROUND: The influence of music on the performance of surgical procedures such as laparoscopy is controversial and methodologically difficult to quantify. Here, outcome measurements using laparoscopic box training tools under standardized conditions might offer a feasible approach. To date, the effect of music exposure at different sound pressure levels (SPL) on outcome has not been evaluated systematically for laparoscopic novices. METHODS: Between May 2017 and October 2018, n = 87 students (49 males, 38 females) from Heidelberg University Medical School performed three different laparoscopy exercises using the "Luebecker Toolbox" that were repeated twice under standardized conditions. Time was recorded for each run. All students were randomly assigned to four groups exposed to the same music compilation but at different SPLs (50-80 dB), an acoustically shielded (earplug) group, or a control group (no intervention). RESULTS: Best absolute performance was shown under exposure to 70 dB in all three exercises (a, b, c) with mean performance time of 121, 142, and 115 s (p < 0.05 for a and c). For the control group mean performance times were 157, 144, and 150 s, respectively. In the earplug group, no significant difference in performance was found compared to the control group (p > 0.05) except for exercise (a) (p = 0.011). CONCLUSION: Music exposure seems to have beneficial effects on training performance. In comparison to the control group, significantly better results were reached at 70 dB SPL, while exposure to lower (50 or 60 dB) or higher (80 dB) SPL as well as under acoustic shielding did not influence performance.


Assuntos
Laparoscopia , Música , Treinamento por Simulação , Estudantes de Medicina , Feminino , Humanos , Masculino , Som
16.
Int J Cancer ; 147(11): 3049-3058, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-32468577

RESUMO

Neoadjuvant chemotherapy (NACT) in early breast cancer (EBC) enables in vivo sensitivity testing and less radical surgery as compared to primary surgery and adjuvant chemotherapy (ACT). The aim of our study is to illustrate trends of systemic treatment of EBC. The study analyzed chemotherapy usage and time trends for patients with EBC treated at 104 German breast units between January 2008 and December 2017. The data were obtained through a quality-controlled benchmarking process. Altogether, 124 084 patients were included, of whom 46 279 (37.3%) received chemotherapy. For 44 765 of these cases, detailed information on systemic treatment and surgery were available. Overall use of chemotherapy declined from 42.0% in 2008 to 32.0% in 2017. During that same time, the proportion of NACT increased from 20.0% to 57.7%, irrespective of tumor subtype. The pathological complete response (pCR) rate (defined as ypT0 ypN0) at surgery after NACT increased from 15.0% to 34.2%. The results from this large cohort from the clinical routine reflect the refined indications for chemotherapy in EBC.


Assuntos
Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/cirurgia , Quimioterapia Adjuvante/métodos , Adulto , Idoso , Neoplasias da Mama/patologia , Feminino , Humanos , Mastectomia , Pessoa de Meia-Idade , Terapia Neoadjuvante , Estadiamento de Neoplasias , Análise de Sobrevida , Resultado do Tratamento
17.
Breast Cancer Res Treat ; 184(2): 627-636, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32816190

RESUMO

PURPOSE: In the ACOSOG Z0011 trial, completing axillary lymph node dissection (cALND) did not benefit patients with T1-T2 cN0 early breast cancer and 1-2 positive sentinel lymph nodes (SLN) undergoing breast-conserving surgery (BCT). This paper reports cALND rates in the clinical routine for patients who had higher (T3-T4) tumor stages and/or underwent mastectomy but otherwise met the ACOSOG Z0011 eligibility criteria. Aim of this study is to determine cALND time trends and non-sentinel axillary metastases (NSAM) rates to estimate occult axillary tumor burden. METHODS: Data were included from patients treated in 179 German breast cancer centers between 2008 and 2015. Time-trend rates were analyzed for cALND of patients with T3-T4 tumors separated for BCT and mastectomy and regarding presence of axillary macrometastases or micrometastases. RESULTS: Data were available for 188,909 patients, of whom 19,009 were identified with 1-2 positive SLN. Those 19,009 patients were separated into 4 cohorts: (1) Patients with T1-T2 tumors receiving BCT (ACOSOG Z0011 eligible; n = 13,741), (2) T1-T2 with mastectomy (n = 4093), (3) T3-T4 with BCT (n = 269), (4) T3-T4 with mastectomy (n = 906). Among patients with T3-T4 tumors, cALND rates declined from 2008 to 2015: from 88.2 to 62.6% for patients receiving mastectomy and from 96.6 to 58.1% in patients receiving BCT. Overall rates for any NSAM after cALND for cohorts 1-4 were 33.4%, 42.3%, 46.9%, 58.8%, respectively. CONCLUSIONS: The cALND rates have decreased substantially in routine care in patients with 'extended' ACOSOG Z0011 eligibility criteria. Axillary tumor burden is higher in these patients than in the ACOSOG Z0011 trial.


Assuntos
Neoplasias da Mama , Linfonodo Sentinela , Axila , Neoplasias da Mama/epidemiologia , Neoplasias da Mama/cirurgia , Feminino , Humanos , Excisão de Linfonodo , Linfonodos/cirurgia , Mastectomia , Mastectomia Segmentar , Linfonodo Sentinela/cirurgia , Biópsia de Linfonodo Sentinela
18.
Breast Cancer Res Treat ; 179(2): 425-433, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31654190

RESUMO

PURPOSE: To explore the ability of intraoperative specimen radiography (SR) to correctly identify positive margins in patients receiving breast conserving surgery (BCS). To assess whether the reoperation rate can be reduced by using this method. METHODS: This retrospective study included 470 consecutive cases receiving BCS due to a primarily diagnosed breast cancer. SR was carried out in two planes, assessing the specimen regarding the presence of the lesion and its relation to all margins. If indicated, re-excision of selective orientations was advised. Under consideration of gross inspection and the SR-findings, it was up to the surgeon whether to perform re-resections. The recommendations for re-excision were, separately for each orientation, compared to the histopathological results, serving as gold standard. RESULTS: Intraoperative SR was performed in 470 cases, thus 2820 margins were assessed. Of those, 2510 (89.0%) were negative and 310 (11.0%) positive. SR identified 2179 (77.3%) margins correctly as negative, whereas 331 (11.7%) clear margins were misjudged as positive. Of 310 infiltrated margins, SR identified 114 (4.0%) correctly, whereas 196 (7.0%) infiltrated margins were missed. This resulted in a sensitivity/specificity of 36.8%/86.8% and PPV/NPV of 25.6%/91.8%. Through targeted re-resections positive margins could be reduced by 31.0% [310 to 214 (7.6%)]. On case level, the rate of secondary procedures could be reduced by 37.0% [from 162 to 102 (21.7%)]. CONCLUSIONS: SR is a helpful tool to identify infiltrated margins and to reduce the rate of secondary surgeries by recommending targeted re-excisions of according orientations in order to obtain a final negative margin status.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/cirurgia , Cuidados Intraoperatórios , Mastectomia Segmentar , Radiografia , Idoso , Biópsia , Feminino , Humanos , Cuidados Intraoperatórios/métodos , Margens de Excisão , Mastectomia Segmentar/métodos , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Radiografia/métodos , Cirurgia Assistida por Computador , Terapêutica , Resultado do Tratamento
19.
Arch Gynecol Obstet ; 301(4): 1037-1045, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32157414

RESUMO

PURPOSE: Little is known about the reason of high short-term complication rates after the subcutaneous placement of breast implants or expanders after mastectomy without biological matrices or synthetic meshes. This study aims to evaluate complications and their risk factors to develop guidelines for decreasing complication rates. METHODS: We included all cases of mastectomy followed by subcutaneous implant or expander placement between 06/2017 and 05/2018 (n = 92). Mean follow-up time was 12 months. RESULTS: Explantation occurred in 15 cases (16.3%). The surgeon's preference for moderate vs. radical subcutaneous tissue resection had a significant influence on explantation rates (p = 0.026), impaired wound healing or infection (requiring surgery) (p = 0.029, p = 0.003 respectively) and major complications (p = 0.018). Multivariate analysis revealed significant influence on complication rates for radical subcutaneous tissue resection (p up to 0.003), higher implant volume (p up to 0.023), higher drain volume during the last 24 h (p = 0.049), higher resection weight (p = 0.035) and incision type (p = 0.011). CONCLUSION: Based on the significant risk factors we suggest the following guidelines to decrease complication rates: favoring thicker skin envelopes after surgical preparation, using smaller implants, removing drains based on a low output volume during the last 24 h and no use of periareolar incision with extension medial or lateral. We should consider ADMs for subcutaneous one-stage reconstructions. The individual surgeon's preference of subcutaneous tissue resection is of highest relevance for short-term complications-this has to be part of internal team discussions and should be considered in future trials for comparable results.


Assuntos
Implante Mamário/efeitos adversos , Neoplasias da Mama/cirurgia , Mastectomia/métodos , Complicações Pós-Operatórias/etiologia , Tela Subcutânea/cirurgia , Implantes de Mama/efeitos adversos , Neoplasias da Mama/patologia , Estudos de Coortes , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
20.
Breast Cancer Res Treat ; 177(2): 457-467, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31236814

RESUMO

PURPOSE: In the ACOSOG Z0011 trial, patients with primary breast cancer (BC) and 1-2 tumor-involved sentinel lymph nodes (SLN) undergoing breast-conserving surgery gained no benefit from completing axillary lymph node dissection (cALND). This paper reports cALND rates performed in clinical routine on patients who would meet the Z0011 criteria. Further, patients still received cALND were analyzed concerning the number of non-sentinel metastases (NSM) to estimate occult axillary tumor burden. METHODS: Data were retrospectively analyzed from patients treated in 179 German breast centers between 2008 and 2015. Time-trend rates were determined for cALND regarding the presence of axillary macrometastases or micrometastases. Descriptive statistics were used to report the number of NSM depending on the number of SLN removed, tumor-involved SLN, tumor stage (pT1-2), and immunohistochemical subtype. Factors associated with NSM were identified using multivariable logistic regression. RESULTS: Altogether, data for 188,909 patients were available, of whom 13,741 (7.3%) were identified eligible for the Z0011 criteria. For these patients, the cALND rate for macrometastases declined from 96.4% in 2008 to 49.7% in 2015, for micrometastases from 86.7 to 5.9%. In total 9773 patients still received cALND, 33.4% of whom had NSM. The NSM rates were: 38.8% for pN(1/1sn), 28.6% for pN(1/2sn), and 50.9% for pN(2/2sn). Hormone receptor (HR) positive/HER2+ showed the highest NSM rate (41.6%), HR-/HER2- the lowest rate (29.4%). CONCLUSIONS: The rate of cALND for ACOSOG Z0011 eligible patients has decreased substantially in routine care in our nationwide cohort. Our data reveal a relatively high prevalence of additional axillary NSM tumor burden.


Assuntos
Axila/patologia , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Linfonodo Sentinela/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais , Neoplasias da Mama/etiologia , Tomada de Decisão Clínica , Estudos de Coortes , Gerenciamento Clínico , Feminino , Humanos , Excisão de Linfonodo , Metástase Linfática , Mastectomia Segmentar , Pessoa de Meia-Idade , Estudos Retrospectivos , Biópsia de Linfonodo Sentinela , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA