Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 112
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Neuroradiol ; 44(3): 203-209, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28262374

RESUMO

BACKGROUND AND PURPOSE: Flow disruption with the WEB device is an innovative technique for the endovascular treatment of wide neck bifurcation aneurysms. Good clinical practice trials have shown high safety of this treatment with good efficacy. Technical developments (single layer devices and smaller microcatheters) facilitate the treatment, potentially leading to enlargement of indications. This series is collecting aneurysms in "atypical" locations for WEB treatment and analyzing safety and efficacy of this treatment. MATERIALS AND METHODS: In each participating center, patients with aneurysms treated with WEB were prospectively included in a local database. Patients treated for aneurysms in "atypical" locations were extracted. Patient and aneurysm characteristics, intraoperative complications, and anatomical results at the end of the procedure and at last follow-up were collected and analyzed. RESULTS: Five French neurointerventional centers included 20 patients with 20 aneurysms in "atypical" locations for WEB treatment treated with WEB. Aneurysm locations were ICA carotid-ophthalmic in 9 aneurysms (45.0%), ICA posterior communicating in 4 (20.0%), Pericallosal artery in 5 (25.0%), and basilar artery between P1 and superior cerebellar artery in 2 (10.0%). There were no complications (thromboembolic or intraoperative rupture) in this series. At follow-up (mean: 7.4 months), adequate occlusion was obtained in 100.0% of aneurysms. CONCLUSIONS: This series confirms that it is possible to enlarge indications of WEB treatment to "atypical" locations with good safety and efficacy. These data have to be confirmed in large prospective series.


Assuntos
Implante de Prótese Vascular/métodos , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Adulto , Idoso , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
2.
J Eur Acad Dermatol Venereol ; 30(1): 36-40, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25631621

RESUMO

INTRODUCTION: Cutaneous arterio-venous malformations (AVM) are high-flow vascular malformations made up of a direct link between arteries and veins without intermediary capillary space. 'Distal limb's AVM', which mean involving hands or feet, are rare and their functional prognosis is often poor. Little is known about their early clinical symptoms. The objectives of this study were to identify early clinical symptoms of distal limb's cutaneous AVMs and to determine their long-term clinical outcome. METHODS: A retrospective study was carried out including adult patients who had distal limb's AVM, who were followed up between January 2000 and November 2013 in two regional tertiary care centres. The information was collected from patients' clinical records and completed by a structured telephone questionnaire. RESULTS: Nineteen patients were included in the study: four (21%) with foot AVM and 15 (79%) with hand AVM. The first clinical symptoms were as follows: swelling (47%), pain (47%), one or several venous dilatations (37%) and rarely abnormal skin colour, hyperthermia and pulsating sensation. The median diagnosis delay was 9 years after the onset of first manifestations. Amongst the 17 patients who underwent a treatment, 53% had embolotherapy session(s), 12% surgery and 35% had both. After an average follow-up of 57.6 months, 31% of the 13 patients contacted who were receiving treatment were in complete remission; 31% had partial remission; 15% had relapse after initial improvement and 23% had treatment failure. Overall, 74% of patients had a serious development of the AVM: 37% had digital or hand amputation, and 42% remained symptomatic and/or unstable. CONCLUSION: This study suggests that initial manifestations of distal limb's AVMs are discreet and non-specific, leading to a diagnosis delay of about 10 years, with poor prognosis. Doctors should evoke the diagnosis earlier, when these symptoms are shown: pain and/or swelling, sometimes with a large vein.


Assuntos
Malformações Arteriovenosas/diagnóstico , Malformações Arteriovenosas/terapia , Pé/irrigação sanguínea , Mãos/irrigação sanguínea , Pele/irrigação sanguínea , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Inquéritos e Questionários , Resultado do Tratamento
3.
Eur Radiol ; 23(10): 2838-45, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23652849

RESUMO

OBJECTIVES: To evaluate the safety and efficacy of a new liquid embolic agent in brain arteriovenous malformation (bAVMs) embolisation. METHODS: A prospective, multicentre series was conducted at 11 interventional centres in Europe to evaluate embolisation of bAVMs with the new liquid embolic agent. Technical conditions, complications, clinical outcome and anatomical results were independently analysed. RESULTS: From December 2005 to December 2008, 117 patients (72 male; 45 female, aged 18-75 years) were included. Clinical presentation was mostly haemorrhage (34.2 %) and seizures (28.2 %). Most AVMs were located in the brain hemispheres (85.5 %). AVMs were <3 cm in 52.1 % of patients and ≥ 3 cm in 47.9 %. Morbidity was observed in 6/117 patients (5.1 %), related to haemorrhagic events in 2 cases and non-haemorrhagic complications in 4 cases. Five patients (4.3 %) died in relation to the treatment (bleeding in 4 patients and extensive venous thrombosis in 1). Complete occlusion of the AVM by embolisation alone was obtained in 23.5 % of patients. Complementary treatment was performed in 82.3 % of patients with partial AVM occlusion, mostly radiosurgery. CONCLUSIONS: In this prospective, multicentre, European, observational series, the new liquid embolic agent proved to be suitable for BAVM embolisation, with acceptable morbidity and mortality and good efficacy. KEY POINTS: • Numerous interventional techniques have been used to embolise brain arteriovenous malformations (AVMs). • This prospective multicentre study demonstrates the suitability of a liquid embolic agent. • The safety of treatment using Onyx is acceptable. • Such embolisation leads to complete AVM occlusion in 23.5 % of patients.


Assuntos
Fístula Arteriovenosa/epidemiologia , Fístula Arteriovenosa/terapia , Dimetil Sulfóxido/uso terapêutico , Embolização Terapêutica/estatística & dados numéricos , Malformações Arteriovenosas Intracranianas/epidemiologia , Malformações Arteriovenosas Intracranianas/terapia , Polivinil/uso terapêutico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fístula Arteriovenosa/diagnóstico por imagem , Embolização Terapêutica/métodos , Europa (Continente)/epidemiologia , Feminino , Hemostáticos/uso terapêutico , Humanos , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos , Radiografia , Fatores de Risco , Resultado do Tratamento , Adulto Jovem
4.
J Eur Acad Dermatol Venereol ; 26(10): 1285-90, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22044599

RESUMO

BACKGROUND: Two types of neonatal haemangiomatosis (NH) are distinguished: diffuse which is associated with a high rate of mortality linked to mucosal/visceral involvement, and benign. OBJECTIVES: First, this study aimed to examine the frequency of mucosal and visceral (especially hepatic) involvement in NH, according to skin extension, and second, it aimed to examine clinical, pathological (with glucose transporter 1 (GLUT-1) immunostaining), and imaging features of NH, including follow-up data. METHODS: This was a descriptive retrospective study carried out in the University Hospital Center of Tours, France. RESULTS: The study included 19 patients with cutaneous NH (number of skin haemangiomas ranging from 5 to >100). Mucosal involvement was observed in 32% of all cases (100% and 19% in diffuse and other cutaneous cases respectively) and hepatic involvement in 42% (67% and 38% respectively). The number of hepatic haemangiomas ranged from 1 to >10. Half of the hepatic haemangiomas cases exhibited increased hepatic arterial blood flow. CONCLUSIONS: Mucosal and hepatic involvement was frequent in cases with a high number of cutaneous haemangiomas (>100), but only frequency of mucosal involvement was statistically significant (P = 0.021).


Assuntos
Hemangioma/patologia , Mucosa/patologia , Vísceras/patologia , Humanos , Recém-Nascido , Estudos Retrospectivos
6.
J Neuroradiol ; 36(3): 147-52, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19223075

RESUMO

BACKGROUND AND PURPOSE: To evaluate the safety and efficacy of onyx for embolization of brain arteriovenous malformations (BAVM). METHODS: A prospective, multicenter study was conducted in France to evaluate embolization of BAVM with onyx. From May 2003 to March 2005, 50 patients (26 females, 24 males; mean age: 34.8 years, range: 16-64years) were included. Clinical presentation was haemorrhage in 22 patients (44.0%), seizures in 16 patients (32.0%), headaches in six patients (12.0%) and progressive neurological deficit in two cases (4.0%). Four patients were asymptomatic (8.0%). RESULTS: One hundred and forty-ninesessions of embolization were performed: one to eight sessions/patient with a mean of 3.0sessions. One hundred and sixteen sessions (77.9%) were performed with onyx, 20 sessions (13.4%) with glue and 13 sessions (8.7%) with onyx and glue. Symptomatic acute postembolization haemorrhage (APEH) was observed in four cases (8.0% per patient). At 1 month, morbidity and mortality related to the treatment were of 8% and 2%, respectively. Complete BAVM occlusion was obtained in 8.3% of cases. In the remaining cases, occlusion rate was between 99 and 80% in 56.3% of patients, 79 and 60% in 16.7%, and less than 60 in 18.7%. In case of incomplete occlusion, complementary treatment was performed by radiosurgery. CONCLUSION: Onyx is suitable for BAVM embolization with acceptable morbidity and mortality.


Assuntos
Angioplastia , Dimetil Sulfóxido/uso terapêutico , Embolização Terapêutica , Malformações Arteriovenosas Intracranianas/terapia , Polivinil/uso terapêutico , Adolescente , Adulto , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Adulto Jovem
7.
Virchows Arch ; 475(1): 127-128, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30888489

RESUMO

The original version of this article contained error. Table 2 was shown in the wrong version, thus corrected table is shown in this article.

8.
Virchows Arch ; 474(6): 755-761, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30810814

RESUMO

Vascular malformations (VMs) are rare congenital anomalies that develop during embryogenesis in different types of vessels. Several triggering factors of cutaneous VMs include trauma, infections, or hormonal changes. We investigated the expression of hormonal receptors (androgen, estrogen, progesterone) in tissue samples of well-characterized VMs. A secondary objective was to identify self-reported triggering factors for these VMs, including hormonal changes, in the cohort of patients. We included patients with VM samples obtained in the tertiary center for vascular anomalies of the University Hospital Center of Tours, France, from January 1, 2007, to August 1, 2018. Immunohistochemistry was used to detect the expression of hormonal receptors (estrogen, progesterone, androgens). We obtained 51 samples from 51 patients: 13 cystic lymphatic malformations (CLMs), 16 venous malformations (VeMs), 11 arteriovenous malformations (AVMs), 4 combined VMs, 4 PIK3CA-related overgrowth spectrum, 1 Parkes-Weber syndrome, 1 Gorham syndrome, and 1 multiple lymphangioendotheliomatosis with thrombopenia. In total, 38 (74.5%) samples were positive for androgen receptor: 11 (84.6%) CLMs, 12 (75.0%) VeMs, 8 (72.2%) AVMs, and 7/11 (63.5%) other samples. All samples were negative for estrogen and progesterone receptors. Triggering factors were self-reported in 7 cases and were most frequently hormonal changes (n = 6, 18.2%). Hormonal triggers were frequent in AVMs (n = 4). Among patients with identified hormonal triggers, VM samples were positive for androgen receptor in 3 and negative in 3. Three-quarters of our VM samples expressed androgen receptor, and most CLM, VeM, and AVM samples were positive. Hormonal triggers were identified in 6/33 patients, mostly with AVMs.


Assuntos
Malformações Arteriovenosas/patologia , Receptores Androgênicos/metabolismo , Receptores de Progesterona/metabolismo , Malformações Vasculares/patologia , Malformações Arteriovenosas/diagnóstico , Feminino , Humanos , Imuno-Histoquímica/métodos , Lactente , Masculino , Pessoa de Meia-Idade , Receptores de Estrogênio/metabolismo , Malformações Vasculares/diagnóstico , Malformações Vasculares/metabolismo
9.
J Neuroradiol ; 35(4): 230-5, 2008 Oct.
Artigo em Francês | MEDLINE | ID: mdl-18486209

RESUMO

This is a case report of successful arterial embolization of a dural fistula using absolute alcohol. In this two-part embolization of a dural fistula of the left sagittal venous sinus, the use of n-BCA (n-butyl-cyanoacrylate) was followed by 1 ml of absolute alcohol four months later. The first procedure, using n-BCA via the external carotid, permitted exclusion of the arterial supply coming from the medial meningeal and occipital arteries. Persistence of the blood supply through the internal carotid prompted us to perform the second procedure, to occlude the tentorium marginalis artery, using 1 ml of 95% ethanol. This was followed by a cranial nerve (III) palsy that was reversible. The three-month follow-up was satisfactory, although arteriography after one year showed revascularization of the fistula, which was successfully treated by Onyx. Routinely used in the treatment of superficial vascular malformations, the use of absolute alcohol intracerebrally appears to be unreliable, with results that were only temporary.


Assuntos
Embolização Terapêutica/métodos , Etanol/administração & dosagem , Malformações Arteriovenosas Intracranianas/terapia , Angiografia Cerebral , Cavidades Cranianas/diagnóstico por imagem , Dimetil Sulfóxido/administração & dosagem , Dura-Máter/diagnóstico por imagem , Embucrilato , Humanos , Injeções , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Pessoa de Meia-Idade , Polivinil/administração & dosagem , Falha de Tratamento
10.
J Neuroradiol ; 34(2): 89-94, 2007 May.
Artigo em Francês | MEDLINE | ID: mdl-17320176

RESUMO

OBJECTIVES: To demonstrate the technical feasibility, safety and results of intracranial aneurysm treatment by coils of 0.018-inch diameter wire (GDC 18) for ruptured and non-ruptured intracranial aneurysms. MATERIALS AND METHODS: From a commune database from five neuroradiological centers, we analysed endovascular technique with Gugliemi Detachable Coils (GDC) 18, complications of technique, acute angiographic occlusion results and long-term angiographic follow-up. Sixty-six percent of aneurysms were ruptured. The mean size of treated aneurysms was 13.7 mm. RESULTS: Overall feasibility of coil 18 treatments was 95%. Acute angiographic results in 110 aneurysms demonstrated total occlusion in 63 aneurysms (57.2%), subtotal occlusion in 37 cases (33.6%), and incomplete occlusion in 10 cases (9%). A second treatment was performed in 15 cases; follow-up demonstrated 60 (61%) total occlusions, 32 (33%) subtotal occlusion and 5 (5%) incomplete. Five patients were lost to follow-up, and 8 patients had died. Stability of occlusion with these coils was 61%. CONCLUSION: Coiling of intracranial aneurysms, ruptured or non-ruptured, using coils with a wire diameter of 0.018-inch is safe, with no more complications than standard coils. Remodelling technique is possible. This type of coils must be considered for treatment of large aneurysms.


Assuntos
Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/terapia , Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Cerebral , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Retratamento , Estudos Retrospectivos , Resultado do Tratamento
11.
AJNR Am J Neuroradiol ; 38(6): 1151-1155, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28450432

RESUMO

BACKGROUND AND PURPOSE: Flow disruption with the Woven EndoBridge (WEB) device is an innovative technique for the endovascular treatment of wide-neck bifurcation aneurysms. The initial version of the device (WEB Double-Layer) was evaluated in the WEB Clinical Assessment of IntraSaccular Aneurysm Therapy (WEBCAST) study, whereas the French Observatory study evaluated both WEB Double-Layer and Single-Layer versions of the device. WEBCAST 2 was designed to evaluate the WEB Single-Layer with Enhanced Visualization. MATERIALS AND METHODS: Patients with wide-neck bifurcation aneurysms for which WEB treatment was possible were included. Clinical data including adverse events and clinical status at 1 month and 1 year were collected and analyzed. A core laboratory evaluated anatomic results at 1 year following the procedure. RESULTS: Ten European neurointerventional centers included 55 patients (38 women; 27-77 years of age; mean, 54.4 ± 10.0 years) with 55 aneurysms. Aneurysm locations were the middle cerebral artery in 25 aneurysms (45.5%), the anterior communicating artery in 16 (29.1%), the basilar artery in 9 (16.4%), and the internal carotid artery terminus in 5 (9.1%). Procedural morbidity and mortality at 1 month were, respectively, 1.8% (1/55 patients) and 0.0% (0/55 patients). Morbidity and mortality at 1 year were, respectively, 3.9% (2/51 patients) and 2.0% (1/51 patients). At 1 year, complete occlusion was observed in 27/50 aneurysms (54.0%); neck remnant, in 13/50 (26.0%); and aneurysm remnant, in 10/50 (20.0%) (adequate occlusion in 40/50, 80.0%). CONCLUSIONS: WEBCAST 2 confirms the high safety and efficacy of WEB aneurysm treatment demonstrated in the WEBCAST and French Observatory studies.


Assuntos
Procedimentos Endovasculares/instrumentação , Aneurisma Intracraniano/terapia , Adulto , Idoso , Procedimentos Endovasculares/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
12.
J Radiol ; 87(11 Pt 1): 1621-34, 2006 Nov.
Artigo em Francês | MEDLINE | ID: mdl-17095957

RESUMO

Malformations of cortical development are increasingly recognized as important causes of epilepsy, developmental delay and other neurological disorders. Our purpose is to present the relevance of the MRI in these pathologies with the clinical, genetic and therapeutic aspects. This classification is based on the three fundamental events of cortical formation: proliferation of neurons and glie in the periventricular zone, migration of postmitotic neurons to the periphery, subsequent cortical organization. MR analysis evaluates particularly the cortical thickness, sulcal and cortical morphology, gray-white matter junction, and looks for gray matter in abnormal location. These data coupled with the familial history, the seizure characteristics and genetic findings should allow an appropriate classification of the lesions. MR imaging allows the detection and classification of cortical malformations. MR imaging findings are primordial to consider surgery when the epilepsy becomes refractory to the anti-epileptic drugs. An adequate classification of these malformations should help to provide to the family an appropriate counseling both in terms of genetics and outcome.


Assuntos
Córtex Cerebral/anormalidades , Epilepsia/diagnóstico , Imageamento por Ressonância Magnética , Malformações do Sistema Nervoso/diagnóstico , Adolescente , Adulto , Neoplasias Encefálicas/diagnóstico , Córtex Cerebral/embriologia , Criança , Pré-Escolar , Diagnóstico Diferencial , Epilepsias Parciais/diagnóstico , Epilepsias Parciais/etiologia , Epilepsia/etiologia , Epilepsia/genética , Epilepsia/cirurgia , Feminino , Ganglioglioma/diagnóstico , Ganglioneuroma/diagnóstico , Aconselhamento Genético , Humanos , Lactente , Recém-Nascido , Masculino , Malformações do Sistema Nervoso/genética , Gravidez , Esclerose Tuberosa/genética
13.
J Radiol ; 87(9): 1089-92, 2006 Sep.
Artigo em Francês | MEDLINE | ID: mdl-16936632

RESUMO

Torticollis in children must always instigate a search for trauma. Many other etiologies can be found. The authors report a case of postmedicinal atlantoaxial rotatory pseudoluxation (AARP) occurring in a child. This child had fallen down in the morning with head trauma followed by headache. Clinically, a stiff neck with an irreducible right rotation of his neck, and an osteotendinous hyperreflexia were noted. There was a C1-C2 rotatory dislocation with no traumatic lesion on the cervical CT scan. After a few hours, the torticollis spontaneously reduced and then reappeared on the left side. This clinical fluctuation and the absorption of metoclopramide (Primpéran) started in the morning for acute gastroenteritis provided the diagnosis of AARP. This entity was confirmed by the good clinical and radiological follow-up and was caused by the substantial ligament laxity of the craniovertebral junction encountered in children. The analysis of medical imaging and the systematic search for a medicinal cause helped make the right diagnosis.


Assuntos
Vértebras Cervicais/lesões , Luxações Articulares/etiologia , Metoclopramida/efeitos adversos , Torcicolo/induzido quimicamente , Torcicolo/complicações , Criança , Humanos , Masculino
14.
Orthop Traumatol Surg Res ; 102(2): 213-6, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26874446

RESUMO

INTRODUCTION: Sclerotherapy offers an alternative to surgery for the treatment of aneurysmal bone cyst (ABC). The main objective of the present study was to assess the radiological efficacy of sclerotherapy in terms of ossification on MRI. Secondary objectives were to assess clinical efficacy on pain evaluation and to analyze recurrence and complications according to type of sclerosing agent and intraoperative imaging technique. MATERIALS AND METHODS: Between 2006 and 2014, 19 patients (7 females, 12 males, aged 3 to 17 years) with ABC treated by sclerotherapy were included. Six received Ethibloc(®), 9 Aetoxisclerol(®), 2 liquid absolute alcohol, and 2 absolute alcohol gel. Assessment used fluoroscopy in 17 cases and CT in 2. Ossification was assessed on MRI and pain on a visual analog scale and HEDEN score. RESULTS: Ossification was complete in 11 cases (84.6%) and partial in 2 (15.4%). Eighteen patients (94.7%) were pain-free at 3 months. There was no recurrence, at a minimum 2 years' follow-up. One case of skin necrosis was observed, associated with use of liquid absolute alcohol; there was 1 case of arterial reflux of Ethibloc(®) under CT control. DISCUSSION: Sclerotherapy enables minimally invasive treatment of lesions that are deep, difficult of access to surgery and potentially damaging. Use of absolute alcohol gel and fluoroscopic control seems to improve the risk/benefit ratio, limiting complications by vascular extravasation of the sclerosing agent, thanks to real-time visualization of diffusion. Its clinical and radiological efficacy makes sclerotherapy and alternative primary treatment choice in ABC. LEVEL OF EVIDENCE: IV, retrospective study.


Assuntos
Cistos Ósseos Aneurismáticos/terapia , Soluções Esclerosantes/uso terapêutico , Escleroterapia , Adolescente , Cistos Ósseos Aneurismáticos/complicações , Cistos Ósseos Aneurismáticos/diagnóstico por imagem , Criança , Pré-Escolar , Diatrizoato/uso terapêutico , Combinação de Medicamentos , Etanol/uso terapêutico , Ácidos Graxos/uso terapêutico , Feminino , Fluoroscopia , Seguimentos , Humanos , Masculino , Dor Musculoesquelética/etiologia , Dor Musculoesquelética/terapia , Osteogênese , Medição da Dor , Polidocanol , Polietilenoglicóis/uso terapêutico , Propilenoglicóis/uso terapêutico , Recidiva , Estudos Retrospectivos , Soluções Esclerosantes/efeitos adversos , Escleroterapia/efeitos adversos , Resultado do Tratamento , Zeína/uso terapêutico
15.
AJNR Am J Neuroradiol ; 37(12): 2280-2286, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27538903

RESUMO

BACKGROUND AND PURPOSE: Endovascular treatment with the flow-disrupter Woven EndoBridge aneurysm embolization system (WEB) is an innovative treatment for wide-neck bifurcation aneurysms. Prospective, multicenter studies have shown the high safety of this technique. Stability of aneurysm occlusion in long-term follow-up has been rarely studied. Moreover the "compression" phenomenon has been reported and seems to be associated with poor anatomic results. This prospective, single-center series analyzes the safety and efficacy of the WEB device in long-term follow-up in relation to WEB shape modification. MATERIALS AND METHODS: All patients with aneurysms treated with the WEB were prospectively included in a data base. Demographics, aneurysm characteristics, adverse events, and anatomic results were retrospectively analyzed. Anatomic results and modification of the WEB shape on the follow-up examinations were independently evaluated by a core laboratory. RESULTS: Thirty-nine patients were included. We observed few complications: intraoperative rupture in no patients (0.0%) and thromboembolic events in 3 patients (7.7%) with a permanent deficit in 1 (2.6%). At short-term, midterm, and long-term follow-up, adequate occlusion was obtained in 86.8%, 83.3%, and 87.5%, respectively. Retreatment rates were low (5.1%). At 6 months, WEB shape modification (compression/retraction) was observed in 31.6% of patients but was not associated with a lower rate of adequate occlusion. CONCLUSIONS: This prospective, single-center series with WEB devices used in 39 patients during 3.5 years confirms data from previous multicenter studies. Treatment can be accomplished with good safety and efficacy, with a high rate of adequate occlusion. Anatomic results were not worse in case of WEB shape modification.


Assuntos
Embolização Terapêutica/instrumentação , Procedimentos Endovasculares/instrumentação , Aneurisma Intracraniano/terapia , Adulto , Embolização Terapêutica/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
16.
AJNR Am J Neuroradiol ; 37(3): 475-80, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26514605

RESUMO

BACKGROUND AND PURPOSE: Intracranial aneurysm treatment with flow diverters has shown satisfying results in terms of aneurysm occlusion, and while some cases of delayed intraparenchymal hemorrhage have been described, no systematic analysis of the risk factors affecting its occurrence has been conducted in a large series of patients. This retrospective analysis of delayed intraparenchymal hemorrhage after flow-diverter treatment is a multicenter, retrospective study using a large series of treated patients to analyze factors affecting the occurrence of delayed intraparenchymal hemorrhage. MATERIALS AND METHODS: Patients treated with flow diverters and presenting with delayed intraparenchymal hemorrhage were included from December 2007 to December 2014 in 7 participating centers in France. Patient and aneurysm characteristics were recorded as were characteristics of bleeding (size, lateralization, and time to bleed), treatment, and clinical outcome after 1, 3, and 6 months. RESULTS: Delayed intraparenchymal hemorrhage occurred in 11 patients between 1 and 21 days after the procedure. In 10 of these patients, hemorrhages were ipsilateral to the treated aneurysms. Five of the 11 underwent surgery, and 9 of the 11 had good clinical outcomes at 6 months (mRS ≤2). CONCLUSIONS: The pathogenesis of delayed intraparenchymal hemorrhage occurring after flow-diverter treatment remains unclear. The multidisciplinary management of delayed intraparenchymal hemorrhage yields a relatively low morbidity-mortality rate compared with the initial clinical presentation.


Assuntos
Hemorragia Cerebral/epidemiologia , Hemorragia Cerebral/etiologia , Procedimentos Endovasculares/efeitos adversos , Aneurisma Intracraniano/cirurgia , Adulto , Procedimentos Endovasculares/métodos , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco
17.
AJNR Am J Neuroradiol ; 37(4): 655-9, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26514608

RESUMO

BACKGROUND AND PURPOSE: Flow disruption with the WEB device is a new technique for the endovascular treatment of wide-neck bifurcation aneurysms. To obtain precise data regarding the safety and efficacy of this treatment with high-quality methodology, the prospective French Observatory study was conducted. Analysis of these data is presented, including 1-year follow-up. MATERIALS AND METHODS: Patients with bifurcation aneurysms for which WEB treatment was indicated were included in this prospective, multicenter Good Clinical Practice study. Clinical data, including adverse events and clinical status at 1 month and 1 year, were collected and independently analyzed by a medical monitor. An independent core laboratory evaluated the anatomic results at 1 year following the procedure. RESULTS: Ten French neurointerventional centers included 62 patients (39 women), 33-74 years of age (mean, 56.6 ± 9.80 years) with 63 aneurysms. Aneurysm locations were the middle cerebral artery in 32 aneurysms (50.8%), anterior communicating artery in 16 (25.4%), basilar artery in 9 (14.3%), and internal carotid artery terminus in 6 (9.5%). Morbidity and mortality at 1 month were, respectively, 3.2% (2/62 patients) and 0.0% (0/62). Morbidity and mortality (unrelated to the treatment) at 1 year were, respectively, 0.0% (0/59) and 3.4% (2/59 patients). At 1 year, complete occlusion was observed in 30/58 aneurysms (51.7%); neck remnant, in 16/58 aneurysms (27.6%); and aneurysm remnant, in 12/58 aneurysms (20.7%). CONCLUSIONS: This prospective French Observatory study showed very good safety of aneurysm treatment with the WEB, with a high rate of adequate aneurysm occlusion at 1 year (79.3%).


Assuntos
Embolização Terapêutica/instrumentação , Embolização Terapêutica/métodos , Aneurisma Intracraniano/terapia , Stents , Adulto , Idoso , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/terapia , Artérias Cerebrais/diagnóstico por imagem , Embolização Terapêutica/efeitos adversos , Feminino , Seguimentos , França , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/mortalidade , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Recidiva , Stents/efeitos adversos , Resultado do Tratamento
18.
AJNR Am J Neuroradiol ; 36(6): 1150-4, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25792534

RESUMO

BACKGROUND AND PURPOSE: Endovascular treatment of wide-neck anterior communicating artery aneurysms can often be challenging. The Woven EndoBridge (WEB) device is a recently developed intrasaccular flow disrupter dedicated to endovascular treatment of intracranial aneurysms. The aim of this study was to investigate the feasibility, safety, and efficacy of the WEB Dual-Layer and WEB Single-Layer devices for the treatment of wide-neck anterior communicating artery aneurysms. MATERIALS AND METHODS: Patients with anterior communicating artery aneurysms treated with the WEB device between June 2013 and March 2014 in 5 French centers were analyzed. Procedural success, technical complications, clinical outcome at 1 month, and immediate and 3- to 6-month angiographic follow-up results were analyzed. RESULTS: Ten patients with unruptured anterior communicating artery aneurysms with a mean neck diameter of 5.4 mm were treated with the WEB. Treatment failed in 3 of the 10 aneurysms without further clinical complications. One patient developed a procedural thromboembolic event, and the other 6 had normal neurologic examination findings at 1-month follow-up. Immediate anatomic outcome evaluation showed adequate occlusion (total occlusion or neck remnant) in 6 of 7 patients. Angiographic control was obtained in all patients, including 6 adequate aneurysm occlusions (3 complete occlusions and 3 neck remnants) at short-term follow-up. CONCLUSIONS: In our small series, treatment of wide-neck anterior communicating artery aneurysms with the WEB device was feasible and safe. However, patient selection based on the aneurysm and initial angiographic findings in the parent artery is important due to the limitations of the WEB device navigation.


Assuntos
Ligas , Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/terapia , Idoso , Angiografia Cerebral , Desenho de Equipamento , Segurança de Equipamentos , Estudos de Viabilidade , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
19.
AJNR Am J Neuroradiol ; 36(5): 922-7, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25655876

RESUMO

BACKGROUND AND PURPOSE: Safety analyses in the French Observatory have shown that treatment of intracranial aneurysms by using flow disruption with the Woven EndoBridge Device (WEB) is safe, with low morbidity and no mortality. The objective of this study was to analyze treatment feasibility, complications, and safety results in patients treated with the Woven EndoBridge Device Dual-Layer (WEB DL) and Woven EndoBridge Device Single-Layer/Single-Layer Sphere (WEB SL/SLS) in the French Observatory. MATERIALS AND METHODS: Patients with bifurcation aneurysms were included in this prospective, multicenter good clinical practices study. A medical monitor independently analyzed procedural and clinical data. The study started with the WEB DL, and secondarily, the WEB SL/SLS was authorized in the study. RESULTS: Between November 2012 and January 2014, 10 French centers included 62 patients with 63 aneurysms. Thirty patients with 31 aneurysms were treated with the WEB DL, and 32 patients with 32 aneurysms, with the WEB SL/SLS. The percentage of anterior communicating artery aneurysms treated with WEB SL/SLS was significantly higher (37.5%) compared with WEB DL (12.9%) (P = .04). The WEB SL/SLS was more frequently used in aneurysms of <10 mm than the WEB DL (respectively, 96.9% and 67.7%; P = .002). Morbidity was similar in both groups (WEB DL, 3.3%; WEB SL/SLS, 3.1%), and mortality was 0.0% in both groups. CONCLUSIONS: This comparative study shows increased use of WEB treatment in ruptured, small, and anterior communicating artery aneurysms when using WEB SL/SLS. There was a trend toward fewer thromboembolic complications with the WEB SL/SLS. With both the WEB DL and WEB SL/SLS, the treatment was safe, with low morbidity and no mortality.


Assuntos
Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/terapia , Adolescente , Adulto , Idoso , Embolização Terapêutica/efeitos adversos , Segurança de Equipamentos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Estudos Prospectivos , Resultado do Tratamento
20.
Obstet Gynecol ; 100(5 Pt 2): 1074-7, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12423810

RESUMO

BACKGROUND: Selective embolization is an effective and reputedly safe method of managing pregnancy-related bleeding. However, we report an ischemic uterine necrosis after arterial embolization. CASE: The patient had heavy postpartum bleeding treated by embolization of the uterine arteries using polyvinyl alcohol particles (diameter 150-250 and 300-600 microm) and gelatin sponge pledgets. Her postoperative recovery was complicated by menorrhagia and pelvic pain. Because of the persistent menorrhagia and risk of infection, a hysterectomy was performed. Histopathology of the hysterectomy specimen revealed massive ischemic myometrial necrosis. CONCLUSION: This complication is most likely related to the small size of the particles used. In the management of postpartum bleeding by arterial embolization, the material of choice is gelatin sponge pledgets, and the use of small particles should be avoided.


Assuntos
Embolização Terapêutica/efeitos adversos , Isquemia/etiologia , Hemorragia Pós-Parto/terapia , Útero/irrigação sanguínea , Útero/patologia , Adulto , Feminino , Humanos , Histerectomia , Menorragia/cirurgia , Necrose , Tamanho da Partícula , Álcool de Polivinil/uso terapêutico , Gravidez , Gravidez Múltipla
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA